MODEL: MD7PA  
Lightning Surge Protectors for  
Electronics Equipment M-RESTER  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
LIGHTNING SURGE PROTECTOR FOR  
PROFIBUS-PA  
(ultra-slim)  
APPLICABLE NETWORK  
PROFIBUS-PA and other networks complied with  
IEC 61158-2  
Functions & Features  
• High discharge current capacity 20 kA (8 / 20 μs), 1 kA (10  
/ 350 μs)  
Caution: Power supply to the bus must be limited to 400 mA  
or less.  
• Ultra-thin 7-mm-wide module can be mounted in high  
density  
• Excellent protection employing multi-stage SPD circuits  
• DIN rail mounting and grounding  
• Shield terminal provided  
GENERAL SPECIFICATIONS  
Construction: Slim-sized front terminal structure  
Degree of protection: IP20  
Connection: Euro terminal block (torque 0.3 N·m)  
Applicable wire size: 0.2 – 2.5 mm  
2, stripped length 8 mm  
7 [.28]  
Grounding: DIN Rail  
Housing material: Flame-resistant resin (black)  
INSTALLATION  
95  
[3.74]  
Operating temperature: -25 to +85°C (-13 to +185°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: DIN Rail (TH35-7.5, 1-mm-thick)  
Oxide film on the surface of an aluminium DIN rail may  
lower the electric conductivity between this module and the  
ground. Use a steel or copper rail.  
98  
[3.86]  
mm [inch]  
Weight: 70 g (2.5 oz)  
MODEL: MD7PA–[1]0[2]  
PERFORMANCE  
LINE TO  
LINE  
LINE TO  
EARTH  
SHLD TO  
EARTH  
ORDERING INFORMATION  
• Code number: MD7PA-[1]0[2]  
Specify a code from below for each of [1] and [2].  
(e.g. MD7PA-FF0/Q)  
Max. continuous  
operating voltage (Uc)  
±±32  
±602  
≤ 5µA  
±ꢀ602  
±ꢁ002  
≤ 5µA  
±ꢀ602*ꢀ  
±ꢁ002*ꢀ  
≤ 5µA*ꢀ  
2oltage protection level  
(Up) @4k2 (.3 / 50 µs)  
• Specify the specification for option code /Q  
(e.g. /C01)  
Leakage current @Uc  
Response time  
≤ 4 nsec. ≤ 30 nsec. ≤ 30 nsec.*ꢀ  
Approx. capacitance  
@ꢀ0 kHz  
ꢀ500 pF  
ꢀ00 pF  
ꢀ00 pF*ꢀ  
[1] SHIELD TERMINAL (to earth)  
FF: Floating  
Max. discharge current  
(Imax)  
30kA (ꢁ / 30 µs)  
.0kA (ꢀ0 / ±50 µs)  
400mA  
FG: Grounding  
Nominal current (IN)  
Internal series resistance  
Surge protection  
.5Ω ±ꢀ0% per line  
IEC 6ꢀ64±-3ꢀ Categories Cꢀ, C3, Dꢀ  
SAFETY APPROVAL  
*. 2alues for the $oating type (FF). Shortcircuited for the ground-  
0: None  
ing type (FG).  
[2] OPTIONS  
blank: none  
/Q: Options other than the above (specify the specification)  
MD7PA SPECIFICATIONS  
ES-8056 Rev.11 Page 1/3  
https://www.m-system.co.jp/  
MODEL: MD7PA  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
RoHS Directive  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]  
8–M3 EURO  
WIRE INSERTION ANGLE: approx. 20°  
TERMINAL  
8
6
5
4
8
DIN RAIL  
ADAPTOR  
6
5
DIN RAIL  
4
(35 mm wide)  
1
2
3
7
1
2
3
7
(1.5 [.06])  
98 [3.86]  
7
[.28]  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Surge Side  
Protected Side  
M-RESTER  
Protected Device  
Series Resistance  
4
1
+
DISCHARGE  
ELEMENT  
PA BUS  
PA BUS  
5
6
8
2
3
7
*2  
SHLD  
(SHLD)  
DISCHARGE  
ELEMENT  
*1  
DIN RAIL ADAPTOR  
(for grounding)  
FG  
*3  
*5  
Crossover Wire  
DIN RAIL  
*4  
Grounding  
*1. Choose the grounding (FG) when the shield wire is to be grounded.  
*2. When SHLD is not isolated from PA BUS, DO NOT connect the surge protector’s terminal 7 to SHLD.  
*3. Oxide film on the surface of an aluminium rail may lower the electric conductivity between this module and the ground.  
Use a steel or copper rail.  
*4. Be sure to ground the DIN rail. Recommended grounding resistance max. 100 ohms.  
*5. Cross-wire from the DIN rail to the metal housing of the protected device to equalize the ground potential.  
Ground only the surge protector when the protected device has no grounding terminal.  
MD7PA SPECIFICATIONS  
ES-8056 Rev.11 Page 2/3  
https://www.m-system.co.jp/  
MODEL: MD7PA  
M-RESTER  
*1  
G
G
G
G
Crossover Wire  
Protected  
Devices  
(Nodes)  
M-RESTER  
G
G
G
Protected  
Devices  
(Nodes)  
Crossover Wire  
*1. Fieldbus devices complying with IEC 61158-2 operate by a supply voltage between  
9V and 32V DC.  
Take the MD7PA’s internal series resistance into consideration when determining the  
cable distance if there is a large current flow on the bus line.  
When the distance between nodes are relatively long (e.g. grouped and separated by cabinets),  
install the MD7PA by each group of devices. Insert the MD7PA at the surge side of the network.  
For detailed information on the network, refer to that provided by PROFIBUS International.  
Specifications are subject to change without notice.  
MD7PA SPECIFICATIONS  
ES-8056 Rev.11 Page 3/3  
https://www.m-system.co.jp/  

相关型号:

MD7PL

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PL-NFF0

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PL-NFF0/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PL-NFF2

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PL-NFF2/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PL-NFG0

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PL-NFG0/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PL-NFG2

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PL-NFG2/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PL-NGF0

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PL-NGF0/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PL-NGF2

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM