[3] OUTPUT
Current
A: 4 – 20 mA DC (Load resistance 600 Ω max.)
B: 2 – 10 mA DC (Load resistance 1200 Ω max.)
C: 1 – 5 mA DC (Load resistance 2400 Ω max.)
D: 0 – 20 mA DC (Load resistance 600 Ω max.)
E: 0 – 16 mA DC (Load resistance 750 Ω max.)
F: 0 – 10 mA DC (Load resistance 1200 Ω max.)
G: 0 – 1 mA DC (Load resistance 12 kΩ max.)
GW: -1 – +1 mA DC (Load resistance 10 kΩ max.)
Z: Specify current (See OUTPUT SPECIFICATIONS)
Voltage
PHASE ANGLE TRANSDUCER
Functions & Features
• Providing a DC output signal in proportion to phase angle
• DC output containing little ripple is ideal for computer
input
• Isolation up to 2000 V AC
• High-density mounting
Typical Applications
• Centralized monitoring and control of power management
system in a manufacturing facility or building
• Measuring phase angle for a motor
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)
3: 0 – 1 V DC (Load resistance 1000 Ω min.)
4: 0 – 10 V DC (Load resistance 10 kΩ min.)
5: 0 – 5 V DC (Load resistance 5000 Ω min.)
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
1W: -10 – +10 mV DC (Load resistance 10 kΩ min.)
2W: -100 – +100 mV DC (Load resistance 100 kΩ min.)
3W: -1 – +1 V DC (Load resistance 1000 Ω min.)
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)
0: Specify voltage (See OUTPUT SPECIFICATIONS)
50
(1.97)
80
(3.15)
136
(5.35)
mm (inch)
[4] POWER INPUT
AC Power
MODEL: MEPA–1[1][2][3]–[4] [5]
B: 100 V AC
C: 110 V AC
D: 115 V AC
F: 120 V AC
G: 200 V AC
H: 220 V AC
J: 240 V AC
ORDERING INFORMATION
• Code number: MEPA-1[1][2][3]-[4][5]
Specify a code from below for each of [1] through [5].
(e.g. MEPA-11PA-C/Q)
• Special output range (For codes Z & 0)
• Specify the specification for option code /Q
(e.g. /C01/S01)
DC Power
S: 12 V DC
R: 24 V DC
CONFIGURATION
1: 3-phase / 3-wire
V: 48 V DC
P: 110 V DC
[1] INPUT (balanced load)
1: 110 V / 5 A AC
[5] OPTIONS
blank: none
2: 110 V / 1 A AC
/Q: With options (specify the specification)
3: 220 V / 1 A AC
4: 220 V / 5 A AC
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
[2] OUTPUT SIGNAL POLARITY
P: Negative in lag, positive in lead
/C02: Polyurethane coating
M: Negative in lead, positive in lag
/C03: Rubber coating
TERMINAL SCREW MATERIAL
/S01: Stainless steel
MEPA SPECIFICATIONS
ES-1925 Rev.1 Page 1/4
http://www.m-system.co.jp/
MODEL: MEPA
■ OPERATION DIAGRAM (example)
GENERAL SPECIFICATIONS
Construction: Plug-in
• Negative in lag, positive in lead
OUT
+10V
Connection: M3.5 screw terminals
OUT
20mA
Screw terminal: Nickel-plated steel (standard) or stainless
steel
12
4
0
Housing material: Flame-resistant resin (black)
Isolation: Voltage input to current input to output to power
Overrange output: Approx. -10 to +120 % at 1 – 5 V
Zero adjustment: -5 to +5 % (front)
Span adjustment: 95 to 105 % (front)
-10V
60°
(Lag)
60°
(Lag)
0
60°
(Lead)
0
60°
(Lead)
• Negative in lead, positive in lag
OUT
20mA
OUT
+10V
INPUT SPECIFICATIONS
Frequency: 50 / 60 Hz
12
4
0
• Current Input
Input burden: ≤ 0.1 VA (Input 1A)
≤ 0.5VA (Input 5A)
-10V
60°
(Lag)
60°
(Lag)
0
60°
(Lead)
0
60°
(Lead)
Operational range: 10 - 120% of rated value
Overload capacity: 1000% @ 3 sec., 200% @ 10 sec., 120%
continuous
Note: When there is no input voltage or 5% or less of the rated
input current, the output may become unstable (hunting).
• Voltage Input
Input burden: Approx. 0.5 VA
Operational range: 85 - 120% of rated value
Overload capacity: 150% @ 10 sec., 120% continuous
■ Input range:
INSTALLATION
Power input
•AC: Operational voltage range: rating -15/+10 %,
50/60 Hz, approx. 2 VA
Lag 60° – 0 – lead 60°
• DC: Operational voltage range: rating ±10 %,
or 85 – 150 V for 110 V rating, ripple 10 %p-p max.,
approx. 2 W (18 mA at 110 V)
Lead 60° – 0 – lag 60°
Operating temperature: -5 to +60°C (23 to 140°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
OUTPUT SPECIFICATIONS
■ DC Current: 0 – 20 mA DC and ± 1 mA
Minimum span: 1 mA
Weight: 400 g (0.88 lb)
Offset: Max. 1.5 times span
Load resistance: Output drive 12 V maximum; 10 V for [±]
output
PERFORMANCE in percentage of span
Accuracy: ±2 % with balanced load
■ DC Voltage: -10 – +12 V DC
Minimum span: 5 mV
Temp. coefficient: ±0.2 %/°C (±0.11 %/°F)
Response time: ≤ 1 sec. (0 – 90 %)
Offset: Max. 1.5 times span
Load resistance: Output drive 1 mA max. at ≥ 0.5 V
Ripple: 0.5 %p-p max. (50/60 Hz)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute
(voltage input to current input to output to power to ground)
MEPA SPECIFICATIONS
ES-1925 Rev.1 Page 2/4
http://www.m-system.co.jp/
MODEL: MEPA
CONNECTION DIAGRAM
■3-PHASE/3-WIRE
SOURCE
3
1
2
VT
FUSE
V
U
v
P2
P3
1S
1L
+
–
9
4
5
6
1
2
OUTPUT
u
K
L
k
l
CT
*
10
11
U(+)
V(–)
POWER**
LOAD
*CT Protector (model: CTM) attached to these terminals.
**The transducer can be powered from the input voltage
when the voltage is sufficiently stable and meets
other supply voltage requirements.
EXTERNAL DIMENSIONS unit: mm (inch)
CLAMP
(top & bottom)
7.8 (.31)
DIN RAIL
35mm wide
8
9
7
6
5
4
2–
4.5 (.18) dia.
MTG HOLE
25 (.98) deep
3
2
10 11
1
11
–M3.5
SCREW
50 (1.97)
107 (4.21)
136 (5.35)
40 (1.57)
50 (1.97)
[3.3 (.13)]
• When mounting, no extra space is needed between units.
TERMINAL ASSIGNMENTS unit: mm (inch)
CT PROTECTOR
(model: CTM)
8
7
6
5
4
9
3
2
10 11
1
MEPA SPECIFICATIONS
ES-1925 Rev.1 Page 3/4
http://www.m-system.co.jp/
MODEL: MEPA
Specifications are subject to change without notice.
MEPA SPECIFICATIONS
ES-1925 Rev.1 Page 4/4
http://www.m-system.co.jp/
MEPA-12P5-B/Q 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
MEPA-12P5-C | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
MEPA-12P5-C/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
MEPA-12P5-D | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
MEPA-12P5-D/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
MEPA-12P5-F | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
MEPA-12P5-F/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
MEPA-12P5-G | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
MEPA-12P5-G/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
MEPA-12P5-H | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
MEPA-12P5-H/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 |
MEPA-12P5-B/Q 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8