MP1100-1123 [MSYSTEM]
2-WIRE TRANSMITTER LIMIT ALARM;型号: | MP1100-1123 |
厂家: | M-SYSTEM |
描述: | 2-WIRE TRANSMITTER LIMIT ALARM |
文件: | 总4页 (文件大小:61K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Limit Alarms M-PAC
MODEL
2-WIRE TRANSMITTER LIMIT ALARM
MP1100-1123
MODEL & SUFFIX CODE SELECTION
50
(1.97)
MP11❑❑–A–❑/❑
MODEL
INPUT TYPE
80
SET
1
SP
ZE
AN
(3.15)
RO
1 : 2-wire transmitter
M•PAC
SET
D
1
EA
DB
AN
D
L
IM
IT
A
L
A
R
M
RELAY CONTACT OUTPUT
0 : Single (Hi) trip, non-latching
1 : Single (Hi) trip, latching
2 : Dual (Hi/Lo) trip, non-latching
SE
B
T
2
D
D
EAD
AN
132
(5.20)
SE
T
2
mm (inch)
SETPOINT CONTROL
Functions & Features
0 : Front-accessed three-turn screwdriver adjust.
2 : Remote dial connections (total resistance 1k – 100kΩ)
3 : DC programmable (0 – 1V)
INPUT RANGE
A : 4 – 20mA DC (2-wire transmitter)
POWER INPUT
• Supplying power to 2-wire current loop and pro-
viding relay contact closure(s) at a preset input level
• Single, latching or dual setpoint • Failsafe opera-
tion available • Deadband adjustable from 1 to 100%
• Indicator LED provided
Typical Applications
F : 120V AC
J : 240V AC
• Annunciator • Various alarm applications
R : 24V DC
S : 12V DC
OPTIONS
GENERAL SPECIFICATIONS
Construction: plug-in
Connection: M3.5 screw terminals on base socket
Housing material: flame-resistant resin (black)
Isolation: input to output to power
(non-isolated between I/O with Option V)
Zero/span adjustments: ±5% (front)
Setpoint adjustments: front accessed three-turn
screwdriver, remote dial potentiometer
or DC input
H : Latching operation for dual trip (112X only);
Reset at power off (5 seconds min.)
R : Reversed relay sense
T : Transmitter output (0 – 1V DC)
V : Relay drive voltage output
X : Lo-trip sense for single trip; Lo/Lo for dual trip
Y : Hi/Hi-trip sense for dual trip (112X only)
Deadband adjustments: front accessed single-turn
screwdriver; 1 – 100%
Front LEDs: red lights turn on at a tripped condition
Power ON timer: relays de-energized for approx. 2
seconds after power is turned on.
ORDERING INFORMATION
Specify code number. (e.g. MP1100-A-F/T/X)
P. 1 / 4
ES-9802 Rev.7
MP1100-1123
INPUT & OUTPUT
INSTALLATION
❑SUPPLY OUTPUT
Power input
Output voltage: 24 – 28V DC with no load
Current rating: 22mA DC maximum
AC:
DC:
operational voltage range: rating ±10%,
50/60 ±2 Hz, approx. 2.5VA
operational voltage range: rating ±10%
(ripple 10% p-p max.)
•Shortcircuit Protection
Current limited: 35mA maximum
90mA at 24V, 180mA at 12V
Operating temperature: -5 to +60°C (23 to 140°F)
Storage temperature: -20 to +85°C (-5 to +185°F)
Operating humidity: 30 to 90% RH (non-condensing)
Mounting: surface (DIN rail available for 11-pin base)
Dimensions
❑INPUT: 4 – 20mA DC
Input resistance: 250Ω
❑REMOTE SETPOINT INPUT
MP11X2: potentiometer; any value of 1k – 100kΩ;
excitation 4V
11-pin base: W50×H80×D132 mm
(1.97"×3.15"×5.20")
MP11X3: 0 – 1V DC
See General Spec. Sheet Figure A.
20-pin base: W80×H101×D136 mm
(3.15"×3.98"×5.35")
❑RELAY CONTACT OUTPUT
•Single/Latching: isolated DPDT relay; de-energized
at trip
See General Spec. Sheet Figure B.
Weight:
400 g (0.88 lbs)
•Dual:
isolated SPDT relay; energized at trip
PERFORMANCE in percentage of span
Repeatability: ±0.2%
Temp. coefficient: ±0.05%/°C (±0.027%/°F)
Response time: 100 milliseconds, typical
Common mode rejection
Rating:
120V AC @3A (cosø=1)
30V DC @3A (resistive load)
Relay life
Electrical: 105 cycles
Mechanical: 107 cycles
For maximum relay life with inductive
60 Hz: greater than 120 dB
DC:
greater than 140 dB
loads, external protection is recommended.
Line voltage effect: ±0.1% over voltage range
Insulation resistance: ≥100MΩ with 500V DC
Dielectric strength: 1000V AC @1 minute
(input to output to power)
❑VOLTAGE OUTPUT (Option V): 24V DC average;
Drives 1.2kΩ or greater coil impedance
2000V AC @1 minute (output to ground)
❑TRANSMITTER OUTPUT (Option T): 0 – 1V DC;
1mA max. (setpoint and process input)
Specifications subject to change without notice.
P. 2 / 4
ES-9802 Rev.7
BLOCK DIAGRAM
❑SINGLE / LATCHING OUTPUT
•11-pin Base
•20-pin Base
Option V
Option V
Z
S
SP.SET DB
Z
S
SP.SET DB
6
7
6
7
13
14
15
17
18
19
13
14
15
17
18
19
N.O.
COM.
N.C.
N.O.
COM.
N.C.
COM-
PAR
COM-
PAR
RELAY
DRIVE
RELAY
DRIVE
RELAY
DRIVE
RELAY
DRIVE
+
–
+
–
AMP
AMP
8
8
+
–
+
+
4
5
1
2
3
EXC
9
11
1
EXC
INPUT
INPUT
HOT /
INPUT
9
9
N.O.
COM.
N.C.
N.O.
COM.
N.C.
–
+
INPUT
HOT /
10
11
10
11
POWER
2
POWER
–
–
3
16
20
NEU /
NEU /
MP111X
LATCH RESET
LATCH RESET
+
4
5
6
7
4
4
5
6
7
8
MP11X2
MP11X3
SP
MP11X0
SP XMTR
–
5
6
7
10
12
SP POT CCW
SP POT W
XMTR COMMON
+
+
SP
PROC XMTR
SP POT CW
Option T
❑DUAL OUTPUT
•11-pin Base
•20-pin Base
Option V
Option V
Z
S
SP.SET DB
Z
S
SP.SET DB
HI
LO
6
7
6
7
13
14
15
17
18
19
13
14
15
17
18
19
N.O.
COM.
N.C.
N.O.
COM-
PAR
COM-
PAR
RELAY
DRIVE
RELAY
DRIVE
RELAY
DRIVE
RELAY
DRIVE
+
–
–
+
AMP
AMP
COM.
N.C.
8
8
SP.SET DB
SP.SET DB
+
–
+
+
4
5
1
2
3
EXC
9
11
1
EXC
INPUT
INPUT
HOT /
INPUT
9
9
N.O.
COM.
N.C.
N.O.
COM.
N.C.
–
+
INPUT
HOT /
COM-
PAR
COM-
PAR
RELAY
DRIVE
RELAY
DRIVE
RELAY
DRIVE
RELAY
DRIVE
+
–
–
+
10
11
10
11
LO
HI
POWER
2
POWER
–
–
3
NEU /
NEU /
MP1122
4
5
6
7
8
4
4
5
6
7
8
LO SP POT CW
LO SP POT W
SP POTS CCW
HI SP POT W
HI SP POT CW
MP1123
LO SP
MP1120
Option T
+
+
5
6
7
8
10
12
16
20
PROC XMTR
LO SP XMTR
HI SP XMTR
SP
COMMON
+
+
+
HI SP
XMTR COMMON
P. 3 / 4
ES-9802 Rev.7
MP1100-1123
TERMINAL ASSIGNMENT
❑SINGLE OUTPUT
KEYS
PIN
MP1100
MP1100
MP1102
MP1102
MP1103
MP1103
N.O. = Normally Open
COM = Common
N.C. = Normally Closed
Proc = Process
Xmtr = Transmitter
SP = Setpoint
W = Wiper
CW = Clockwise
CCW = Counterclockwise
w/Option T
w/Option T
w/Option T
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
POWER (Hot/+)
No Connection
POWER (Hot/+) POWER (Hot/+) POWER (Hot/+) POWER (Hot/+)
No Connection No Connection No Connection No Connection
POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–)
POWER (Hot/+)
No Connection
INPUT +
INPUT –
N.O.
COM *
N.C. *
N.O.
No Connection
No Connection
No Connection
No Connection
SP Xmtr +
INPUT +
Xmtr Common
INPUT –
Proc Xmtr +
N.O.
COM *
N.C. *
No Connection
N.O.
COM
No Connection
SP Pot CCW
SP Pot W
SP Pot CW
No Connection
INPUT +
No Connection
INPUT –
No Connection
N.O.
COM *
N.C. *
No Connection
N.O.
No Connection
SP Pot CCW
SP Pot W
SP Pot CW
SP Xmtr +
INPUT +
Xmtr Common
INPUT –
Proc Xmtr +
N.O.
COM *
N.C. *
No Connection
N.O.
COM
No Connection
SP –
SP +
No Connection
No Connection
INPUT +
No Connection
INPUT –
No Connection
N.O.
COM *
N.C. *
No Connection
N.O.
COM
No Connection
SP –
SP +
No Connection
SP Xmtr +
INPUT +
Xmtr Common
INPUT –
Proc Xmtr +
N.O.
COM *
N.C. *
No Connection
N.O.
COM
*Pins used for Option V
20-pin = 14(+) - 15(–)
11-pin = 7(+) - 8(–)
COM
N.C.
COM
N.C.
No Connection
N.C.
No Connection
N.C.
No Connection
N.C.
No Connection
N.C.
No Connection
❑LATCHING OUTPUT
KEYS
PIN
MP1110
MP1110
MP1112
MP1112
MP1113
MP1113
N.O. = Normally Open
COM = Common
N.C. = Normally Closed
Proc = Process
w/Option T
w/Option T
w/Option T
1
2
POWER (Hot/+)
No Connection
POWER (Hot/+) POWER (Hot/+) POWER (Hot/+) POWER (Hot/+)
No Connection No Connection No Connection No Connection
POWER (Hot/+)
No Connection
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–)
Xmtr = Transmitter
SP = Setpoint
W = Wiper
CW = Clockwise
CCW = Counterclockwise
No Connection
No Connection
No Connection
No Connection
No Connection
INPUT +
No Connection
INPUT –
No Connection
N.O.
No Connection
No Connection
No Connection
No Connection
SP Xmtr +
INPUT +
Xmtr Common
INPUT –
No Connection
SP Pot CCW
SP Pot W
SP Pot CW
No Connection
INPUT +
No Connection
INPUT –
No Connection
N.O.
No Connection
SP Pot CCW
SP Pot W
SP Pot CW
SP Xmtr +
INPUT +
Xmtr Common
INPUT –
Proc Xmtr +
N.O.
No Connection
SP –
SP +
No Connection
No Connection
INPUT +
No Connection
INPUT –
No Connection
N.O.
No Connection
SP –
SP +
No Connection
SP Xmtr +
INPUT +
Xmtr Common
INPUT –
Proc Xmtr +
N.O.
*Pins used for Option V
20-pin = 14(+) - 15(–)
Proc Xmtr +
N.O.
COM *
COM *
COM *
COM *
COM *
COM *
N.C. *
N.C. *
N.C. *
N.C. *
N.C. *
N.C. *
Latch Reset
N.O.
Latch Reset
N.O.
Latch Reset
N.O.
Latch Reset
N.O.
Latch Reset
N.O.
Latch Reset
N.O.
COM
COM
COM
COM
COM
COM
N.C.
N.C.
N.C.
N.C.
N.C.
N.C.
Latch Reset
Latch Reset
Latch Reset
Latch Reset
Latch Reset
Latch Reset
❑DUAL OUTPUT
KEYS
PIN
MP1120
MP1120
MP1122
MP1122
MP1123
MP1123
N.O. = Normally Open
COM = Common
N.C. = Normally Closed
Proc = Process
w/Option T
w/Option T
w/Option T
1
2
POWER (Hot/+)
No Connection
POWER (Hot/+) POWER (Hot/+) POWER (Hot/+) POWER (Hot/+)
No Connection No Connection No Connection No Connection
POWER (Hot/+)
No Connection
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–)
Xmtr = Transmitter
SP = Setpoint
W = Wiper
CW = Clockwise
CCW = Counterclockwise
INPUT +
INPUT –
N.O.
COM * Hi Set No Connection
N.C. *
N.O.
No Connection
No Connection
No Connection
Lo SP Pot CW
Lo SP Pot W
SP Pots CCW
Hi SP Pot W
Hi SP Pot CW
INPUT +
Lo SP Pot CW
Lo SP Pot W
SP Pots CCW
Hi SP Pot W
Hi SP Pot CW
INPUT +
No Connection
Lo SP +
SP Common
Hi SP +
No Connection
INPUT +
No Connection
Lo SP +
SP Common
Hi SP +
No Connection
INPUT +
No Connection
INPUT +
*Pins used for Option V
20-pin:
Hi Set = 19(+) - 18(–)
Lo Set = 15(+) - 14(–)
11-pin:
COM * Lo Set Proc Xmtr +
No Connection
INPUT –
No Connection
N.O.
Proc Xmtr +
INPUT –
Lo SP Xmtr +
N.O.
No Connection
INPUT –
No Connection
N.O.
Proc Xmtr +
INPUT –
Lo SP Xmtr +
N.O.
N.C. *
INPUT –
Lo SP Xmtr +
N.O.
Hi Set = 7(+) - 8(–)
Lo Set = 10(+) - 11(–)
COM * Lo Set COM * Lo Set COM * Lo Set COM * Lo Set COM * Lo Set
N.C. *
N.C. *
N.C. *
N.C. *
N.C. *
Hi SP Xmtr +
N.O.
No Connection
N.O.
Hi SP Xmtr +
N.O.
No Connection
N.O.
Hi SP Xmtr +
N.O.
COM * Hi Set COM * Hi Set COM * Hi Set COM * Hi Set COM * Hi Set
N.C. *
N.C. *
N.C. *
N.C. *
N.C. *
Xmtr Common
No Connection
Xmtr Common
No Connection
Xmtr Common
Specifications subject to change without notice.
P. 4 / 4
ES-9802 Rev.7