MPAU-B2MG-D

更新时间:2024-10-29 22:38:59
品牌:MSYSTEM
描述:Plug-in Signal Conditioners M-UNIT

MPAU-B2MG-D 概述

Plug-in Signal Conditioners M-UNIT

MPAU-B2MG-D 数据手册

通过下载MPAU-B2MG-D数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
MODEL: MPAU  
Plug-in Signal Conditioners M-UNIT  
[2] EXCITATION  
L: 12 V DC / 40 mA  
M: 24 V DC / 25 mA  
FREQUENCY TRANSMITTER  
(selectable range)  
Functions & Features  
[3] OUTPUT  
• Converting the output from a pulse-type transducer into a  
standard process signal  
Current  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
• Open collector, mechanical contact, proximity sensor,  
voltage pulse and 2-wire current pulse inputs  
• Output decreases gradually with no input  
• Excitation  
• Isolation up to 2000 V AC  
• High-density mounting  
Typical Applications  
• Positive displacement flowmeters, turbine  
flowmeters and vortex flowmeters  
• Measuring rotation speed of a machine generating dry  
contact signals  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 100 Ω min.)  
4: 0 – 10 V DC (Load resistance 1000 Ω min.)  
5: 0 – 5 V DC (Load resistance 500 Ω min.)  
6: 1 – 5 V DC (Load resistance 500 Ω min.)  
4W: -10 – +10 V DC (Load resistance 2000 Ω min.)  
5W: -5 – +5 V DC (Load resistance 1000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
50  
(1.97)  
80  
(3.15)  
[4] POWER INPUT  
AC Power  
123  
(4.84)  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
mm (inch)  
MODEL: MPAU–[1][2][3]–[4][5]  
ORDERING INFORMATION  
· Code number: MPAU-[1][2][3]-[4][5]  
Specify a code from below for each [1] through [5].  
(e.g. MPAU-A1LA-B/Q)  
DC Power  
S: 12 V DC  
R: 24 V DC  
V: 48 V DC  
•Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01/SET)  
[5] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
[1] INPUT  
A1: Open collector  
A2: Mechanical contact  
B1: Proximity sensor  
B2: Voltage pulse  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
H: Two-wire current pulse  
/C03: Rubber coating  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
MPAU SPECIFICATIONS  
ES-1690 Rev.8 Page 1/4  
http://www.m-system.co.jp/  
MODEL: MPAU  
EX-FACTORY SETTING  
Detecting level:  
/SET: Preset according to the Ordering Information Sheet  
(No. ESU-1690)  
Excitation 12 V  
Sensing: 12 V / 1.5 mA  
ON/OFF level  
ON: ≤ 0.8 kΩ / 1.0 V  
OFF: ≥1.7 kΩ / 2.5 V  
Excitation 24 V  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection: M3.5 screw terminals  
Sensing: 24 V / 3 mA  
ON/OFF level  
Screw terminal: Chromated steel (standard) or stainless  
steel  
ON: ≤ 0.35 kΩ / 1.0 V  
OFF: ≥ 0.8 kΩ / 2.5 V  
Proximity Sensor  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
Overrange output: Approx. 0 to 120 % at 1 – 5V  
Zero adjustment: -5 to +5 % (front)  
Frequency range: 0 – 1 mHz through 9.999 kHz  
(If not specified the default value is used: 0 - 9.999 kHz)  
Pulse width time requirement: ≥ 20 μsec.  
Waveform: Square or sinusoidal  
Span adjustment: 95 to 105 % (front)  
Chattering protection: Filter provided for mechanical  
contact input (time constant: 1 msec.)  
Input monitor LED: Red LED blinks according to the input.  
Status indicator: Green LED turns ON in normal  
operating conditions.  
Detecting level: Input voltage ±50 V (±30 V to conform with  
EU Directive)  
≤ 0 mV for Lo, ≥ 150 mV for Hi  
Input impedance: ≥ 20 kΩ  
Input pulse sensing: DC coupled  
Voltage Pulse  
Frequency adjustments: Rotary switches (front)  
Non-uniform pulse compensation: Input pulses divided and  
then multiplied for stabilizing the output; dividing factor  
adjustable with the front rotary switches (1/1 – 1/ 16,  
factory default 1/1)  
Frequency range: 0 – 1 mHz through 99.99 kHz  
(If not specified the default value is used: 0 - 9.999 kHz)  
Pulse width time requirement: ≥ 4 μsec.  
Waveform: Square or sinusoidal  
Detecting level: Input voltage ±50 V (±30 V to conform with  
EU Directive)  
Damper: Time constant adjustable within 0 to 5 sec.  
(factory default 0 sec.) to provide a first order lag output  
≤ 1 V DC for Lo, ≥ 2 V DC for Hi  
Input impedance: ≥ 20 kΩ  
INPUT SPECIFICATIONS  
Excitation: Shortcircuit protection;  
12 V DC @ 40 mA (approx. 43 mA at shortcircuit)  
or 24 V DC @ 25 mA (approx. 33 mA at shortcircuit)  
Open Collector  
Two-wire Current Pulse  
Frequency range: 0 – 1 mHz through 99.99 Hz  
(If not specified the default value is used: 0 - 99.99 Hz)  
Pulse width time requirement: ≥ 10 msec.  
Input resistance: 200 Ω  
Frequency range: 0 – 1 mHz through 99.99 kHz  
(If not specified the default value is used: 0 - 9.999 kHz)  
Pulse width time requirement: 4 μsec. min.  
Detecting level:  
Input range: 0 – 30 mA  
Detecting level: ≤ 5 mA for Lo, ≥ 10 mA for Hi  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
Excitation 12 V  
Sensing: 12 V / 1.5 mA  
Minimum span: 1 mA  
ON/OFF level  
Offset: Max. 1.5 times span  
ON: ≤ 0.8 kΩ / 1.0 V  
Load resistance: Output drive 15 V max.  
DC Voltage: -10 – +12 V DC  
Minimum span: 5 mV  
OFF: ≥1.7 kΩ / 2.5 V  
Excitation 24 V  
Sensing: 24 V / 3 mA  
Offset: Max. 1.5 times span  
ON/OFF level  
Load resistance: Output drive 10 mA max.; 5 mA for  
negative voltage output; at ≥ 0.5 V  
ON: ≤ 0.35 kΩ / 1.0 V  
OFF: ≥ 0.8 kΩ / 2.5 V  
Mechanical Contact  
Frequency range: 0 – 1 mHz through 9.999 Hz  
(If not specified the default value is used: 0 - 9.999 Hz)  
Pulse width time requirement: 10 msec. min.  
INSTALLATION  
Power input  
AC: Operational voltage range: rating ±10 %,  
MPAU SPECIFICATIONS  
ES-1690 Rev.8 Page 2/4  
http://www.m-system.co.jp/  
MODEL: MPAU  
50/60 ±2 Hz, approx. 4 VA  
DC: Operational voltage range: rating ±10 %,  
ripple 10% p-p max.; approx. 2.5 W (100 mA at 24 V)  
Operating temperature: -5 to +60°C (23 to 140°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 350 g (0.77 lb)  
PERFORMANCE in percentage of span  
Accuracy: ±0.1 %  
Temp. coefficient: ±0.01 %/°C (±0.006 %/°F)  
Response time: ≤ 0.5 sec. + one pulse cycle (0 –  
90 %; with damper set to 0 sec.)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute (input to output  
to power to ground)  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Low Voltage Directive  
EN 61010-1  
Installation Category II  
Pollution Degree 2  
Input or output to power: Reinforced insulation (300 V)  
Input to output: Basic insulation (300 V)  
RoHS Directive  
EN 50581  
EXTERNAL VIEW  
•Input Frequency SW  
A: 103 (1 to 9)  
Input Monitor LED  
B: 102 (0 to 9)  
Status LED  
C: 101 (0 to 9)  
Zero Adj.  
D: 100 (0 to 9)  
Span Adj.  
RANGE: Scaling Factor (0 to 7)  
Damper Adj.  
1/n: Dividing Factor SW  
(1/1 to 1/16)  
(for non-uniform pulse)  
MPAU SPECIFICATIONS  
ES-1690 Rev.8 Page 3/4  
http://www.m-system.co.jp/  
MODEL: MPAU  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
CLAMP  
(top & bottom)  
7.8 (.31)  
DIN RAIL  
35mm wide  
6
5
4
3
2–  
4.5 (.18) dia.  
MTG HOLE  
15 (.59) deep  
7
8
1
2
8–  
M3.5  
SCREW  
50 (1.97)  
103 (4.06)  
123 (4.84)  
40 (1.57)  
50 (1.97)  
[3.3 (.13)]  
• When mounting, no extra space is needed between units.  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
INPUT MON.  
FREQUENCY SW  
Z
S DAMPER  
Isolation  
Waveform  
Shaper  
Digital  
Computation  
Output  
Driver  
+
3
4
5
6
1
2
7
8
+
INPUT  
OUTPUT  
POWER  
SENSOR EXCITATION  
+
DIVIDING FACTOR SW  
Excitation  
Supply  
U(+)  
V(–)  
STATUS MON.  
Base Socket  
Input Connection Examples  
Open Collector or Mechanical Contact  
2-Wire Current Pulse  
200Ω  
+
+
3
4
5
+
3
4
5
20kΩ  
Vsns  
20kΩ  
Vsns  
2-WIRE  
PICK-UP  
PWR  
8kΩ  
Voltage Pulse or Proximity Sensor  
+
+
3
4
5
20kΩ  
Vsns  
PWR  
Specifications are subject to change without notice.  
MPAU SPECIFICATIONS  
ES-1690 Rev.8 Page 4/4  
http://www.m-system.co.jp/  

MPAU-B2MG-D 相关器件

型号 制造商 描述 价格 文档
MPAU-B2MG-D/Q MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
MPAU-B2MG-F MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
MPAU-B2MG-F/Q MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
MPAU-B2MG-G MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
MPAU-B2MG-G/Q MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
MPAU-B2MG-H MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
MPAU-B2MG-H/Q MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
MPAU-B2MG-J MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
MPAU-B2MG-J/Q MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
MPAU-B2MG-R MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格

MPAU-B2MG-D 相关文章

  • HARTING(浩亭)圆形连接器产品选型手册
    2024-10-31
    6
  • HYCON(宏康科技)产品选型手册
    2024-10-31
    6
  • GREEGOO整流二极管和晶闸管产品选型手册
    2024-10-31
    7
  • 西门子豪掷106亿美元,战略收购工程软件巨头Altair
    2024-10-31
    8