PDU-HN3N-F/Q 概述
Plug-in Signal Conditioners M-UNIT
PDU-HN3N-F/Q 数据手册
通过下载PDU-HN3N-F/Q数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: PDU
Plug-in Signal Conditioners M-UNIT
[1] INPUT
A: Dry contact
B: Voltage pulse (Specify sensitivity)
C: 5 V pulse (sensitivity 2 V)
PULSE SCALER
(pulse dividing; selectable range)
D: 12 V/24 V pulse (sensitivity 5 V)
H: Two-wire current pulse
Functions & Features
• Galvanically isolating pulse rate signals and converting
them into convenient engineering unit
• Excitation
[2] OUTPUT
• Scaling factor adjustable with the front switches
• Uniform output pulse
A: Open collector (max. 100 kHz)
M: 5 V pulse (max. 100 kHz)
N: 12 V pulse (max. 100 kHz)
P: 24 V pulse (max. 100 kHz)
H: Relay contact (max. 5 Hz)
( ) = Max. frequency
• Various outputs (relay, open collector and voltage pulses)
• Isolation up to 2000 V AC
• High-density mounting
Typical Applications
• Positive displacement flowmeters and turbine meters
• Dry contact signal produced at rotating machine
[3] OUTPUT PULSE WIDTH
1: One-shot output (5 – 200 μsec.)
(Not selectable with relay contact.)
2: One-shot output (0.18 – 9 msec.)
(Not selectable with relay contact.)
3: One-shot output (9 – 400 msec.)
50
(1.97)
80
(3.15)
[4] OUTPUT LOGIC
N: The same as the input
R: Inverted
127
(5)
mm (inch)
[5] POWER INPUT
AC Power
MODEL: PDU–[1][2][3][4]–[5][6]
B: 100 V AC
C: 110 V AC
D: 115 V AC
F: 120 V AC
G: 200 V AC
H: 220 V AC
J: 240 V AC
ORDERING INFORMATION
• Code number: PDU-[1][2][3][4]-[5][6]
Specify a code from below for each of [1] through [6].
(e.g. PDU-CM1N-B/Q)
• Use Ordering Information Sheet (No. ESU-1368). Default
setting (table below) will be used if not otherwise specified.
• Specify the specification for option code /Q
(e.g. /C01/S01)
DC Power
S: 12 V DC
R: 24 V DC
Factory default setting
V: 48 V DC
ITEM
DEFAULT
0
^
Scaling factor 1 / (1X10 )
[6] OPTIONS
blank: none
Approx. 50% duty ratio at the max.
Output pulse input frequency (400 msec. max.);
/Q: With options (specify the specification)
width
Limited to the range indicated in Out-
put Pulse Width code 3 for relay output
Without;
For dry contact input with frequency
≤10 Hz, the filter is automatically
provided.
Filter
PDU SPECIFICATIONS
ES-1368 Rev.10 Page 1/4
http://www.m-system.co.jp/
MODEL: PDU
Hi/Lo level: ≤ 5 mA for Lo, ≥ 15 mA for Hi
■ Voltage pulse waveform
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
Volts
50V max.
/C02: Polyurethane coating
/C03: Rubber coating
TERMINAL SCREW MATERIAL
/S01: Stainless steel
Amplitude
Vinp-p
DC Offset
t
GENERAL SPECIFICATIONS
Construction: Plug-in
Connection: M3.5 screw terminals
Screw terminal: Chromated steel (standard) or stainless
steel
OUTPUT SPECIFICATIONS
■ Open Collector: 50 V DC @ 50 mA (resistive load)
Maximum frequency: 100 kHz with load resistance ≤ 1 kΩ
Saturation voltage: 1.0 V DC
■ Voltage Pulse:
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
Input pulse sensing: DC coupled
High level: Rating (5, 12 or 24 V) ±10 %
Low level: ≤ 0.5 V
Sensitivity adjustment: Single-turn screwdriver adjustment
(front); 0 – ±7 V
Maximum frequency: 100 kHz
Load resistance:
Hysteresis (deadband): Approx. 0.5 V
Input filter: Provided for 10 Hz or lower output frequency
(time constant approx. 1 msec.)
1 kΩ min. for 5 V
2.4 kΩ min. for 12 V,
Scaling factor adjustment: 10-position rotary switches
(front);
4.8 kΩ min. for 24 V
■ Relay Contact:
1 / ( m × 10 ^n) m = 1 - 9999, n = 0 - 6
Output pulse width adjustment: Multi-turn screwdriver
adjustment (front); 5 μsec. – 400 msec.
120 V AC @ 200 mA (cos ø = 1)
30 V DC @ 200 mA (resistive load)
Electrical life 3 × 10 cycles (rate 30/min.)
5
Maximum switching voltage: 250 V AC or 30 V DC
Maximum switching power: 24 VA or 6 W
Minimum load: 5 V DC @ 10 mA
INPUT SPECIFICATIONS
Frequency range: 0 – 100 kHz (10 Hz max. with filter)
Excitation: 12 V DC @ 30 mA; shortcircuit protection
Pulse width time requirement: 5 μsec. min. (10 ms with
filter)
Mechanical life: 2 × 10 cycles
7
For maximum relay life with inductive loads, external
protection is recommended.
Maximum frequency: 5 Hz
■ Dry Contact
Sensing: 7.5V DC @ 1mA
ON/OFF level: ≥ 30 kΩ/5 V for OFF; ≤ 1 kΩ/1 V for ON
■ Voltage Pulse: Specify DC offset and amplitude.
Waveform: Square or sine
OUTPUT PULSE WIDTH
• One-shot Output: Preset pulse width ±20 %;
The pulse width is factory set to approx. 50 % duty ratio at
the maximum frequency. For relay output, it is limited
within the range indicated in Code 3 specification.
Adjustable pulse width: 5 μsec. – 400 msec.
Input impedance: 10 kΩ min.
Input amplitude: 2 – 50 Vp-p
Offset: 0 – ±7 V
Max. voltage between input terminals: ±32 V
• 5V, 12V, 24V Pulse
INSTALLATION
Power input
Waveform: Square or sine
Input impedance: 10 kΩ min.
• AC: Operational voltage range: rating ±10 %,
50/60 ±2 Hz, approx. 2 VA
Detecting level
(Input: 5 V pulse: 12 V/24 V pulse)
•DC: Operational voltage range: rating ±10 %,
ripple 10 %p-p max., approx. 2 W (80 mA at 24 V)
Operating temperature: -5 to +60°C (23 to 140°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
V
H
: ≥ 3 V: ≥ 6 V
VL
: ≤ 1 V: ≤ 4 V
■ Two-wire Current Pulse
Input resistance: Receiving resistor 220 Ω
Maximum current: ±50 mA
Weight: 350 g (0.77 lb)
PDU SPECIFICATIONS
ES-1368 Rev.10 Page 2/4
http://www.m-system.co.jp/
MODEL: PDU
PERFORMANCE
Response time:
≤ 25 μsec. without filter
≤ 2 msec. with filter
≤ 20 msec. with relay contact pulse
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute (input to output
to power to ground)
EXTERNAL VIEW
Note: This unit is factory calibrated according to the Ordering Information Sheet.
Sensitivity Adj.
103
102
101
100
10n
Pulse
Rate
Not Used
Pulse Width Adj.
Front Cover (open)
OUTPUT LOGIC
VOLTAGE PULSE
OUTPUT
OPEN COLLECTOR
or RELAY CONTACT
INPUT TYPE
PULSE LOGIC
INPUT
H
H
OFF
Voltage Pulse Input
2-wire Current Pulse Input
ON current (H)
Non Inverted
Inverted
L
L
ON
H
H
OFF
OFF current (L)
L
L
ON
OFF
H
OFF
Non Inverted
Inverted
ON
L
ON
Dry Contact Input
OFF
H
OFF
ON
L
ON
The pulse width in one-shot means the bold lined section of a pulse waveform.
PDU SPECIFICATIONS
ES-1368 Rev.10 Page 3/4
http://www.m-system.co.jp/
MODEL: PDU
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
CLAMP
(top & bottom)
7.8 (.31)
DIN RAIL
35mm wide
6
5
4
3
2–4.5 (.18) dia.
MTG HOLE
15 (.59) deep
7
8
1
2
8–M3.5
SCREW
50 (1.97)
107 (4.21)
127 (5)
40 (1.57)
50 (1.97)
[3.3 (.13)]
• When mounting, no extra space is needed between units.
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
SENSITIVITY
ADJ.
SCALING
FACTOR ADJ.
PULSE
WIDTH ADJ.
Isolation
Waveform
Shaper
Output
Driver
+
–
3
4
5
6
1
2
7
8
+
Scaler
One-shot
INPUT
OUTPUT
POWER
–
SENSOR EXCITATION
+
12V Supply
U(+)
V(–)
Base Socket
Input Connection Examples
Output Connection Examples
■ Dry Contact
+7.5V
■ Open Collector
■ Voltage Pulse
■ 2-Wire Current Pulse
• Built-in Excitation
7.5kΩ
220
Ω
+
–
+
–
+
3
4
5
–
+
1
2
+
–
+
–
1
2
+
–
+
–
3
4
5
2-WIRE
PICK-UP
–
PWR
+
Vsns
■ Voltage Pulse
• External DC Supply
■ Relay Contact
• AC Powered
Relay or
Counter Coil
220Ω
+
–
–
+
+
–
+
3
4
5
–
+
1
3
4
5
2-WIRE
PICK-UP
Varistor or Spark
Quenching CIrcuit
LOAD
2
DC SUPPLY
Vsns
PWR
+
–
U
• DC Powered
Relay or
Counter Coil
1
2
Spark Quenching
Diode
LOAD
Specifications are subject to change without notice.
PDU SPECIFICATIONS
ES-1368 Rev.10 Page 4/4
http://www.m-system.co.jp/
PDU-HN3N-F/Q 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
PDU-HN3N-G | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
PDU-HN3N-G/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
PDU-HN3N-H | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
PDU-HN3N-H/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
PDU-HN3N-J | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
PDU-HN3N-J/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
PDU-HN3N-R | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
PDU-HN3N-R/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
PDU-HN3N-S | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
PDU-HN3N-S/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 |
PDU-HN3N-F/Q 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8