R3-AV8S [MSYSTEM]

Remote I/O R3 Series DC VOLTAGE INPUT ALARM MODULE;
R3-AV8S
型号: R3-AV8S
厂家: M-SYSTEM    M-SYSTEM
描述:

Remote I/O R3 Series DC VOLTAGE INPUT ALARM MODULE

输入元件
文件: 总4页 (文件大小:138K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: R3-AV8  
Remote I/O R3 Series  
CAUTION  
UNUSED INPUT CHANNELS  
Set the unused channels to the ranges other than 1 - 5 V.  
Otherwise, set them as "Unused" with PC Configurator  
software: R3CON. Unused channels left open with 1 – 5 V  
setting are equal to the input lower than -15 %, which sets a  
data abnormality at the PLC or the host device.  
Open circuit with the input range set to ±10 V means 50 %  
of the full-scale. An alarm setpoint must be set to a value  
that does not trip an unwanted alarm.  
DC VOLTAGE INPUT ALARM MODULE  
(8 points, isolated)  
27.5 [1.08]  
130  
[5.12]  
GENERAL SPECIFICATIONS  
Connection  
109  
[4.29]  
Internal bus: Via the Installation Base (model: R3-BSx)  
Input: M3 separable screw terminal (torque 0.5 N·m)  
Internal power: Via the Installation Base (model: R3-BSx)  
Screw terminal: Nickel-plated steel  
mm [inch]  
MODEL: R3–AV8[1][2]  
Isolation: Input 1 to input 2 to input 3 to input 4 to input 5 to  
input 6 to input 7 to input 8 to internal bus or internal power  
Input range: Selectable with the side DIP SW (per 4  
channels)  
ORDERING INFORMATION  
• Code number: R3-AV8[1][2]  
Specify a code from below for each of [1] and [2].  
(e.g. R3-AV8W/CE/Q)  
Conversion rate: Selectable with the side DIP SW  
RUN indicator: Bi-color (red/green) LED;  
Red when the bus A operates normally;  
Green when the bus B operates normally;  
Amber when both buses operate normally.  
ERR indicator: Bi-color (red/green) LED;  
Red with input circuit abnormality (AD converter response  
failure);  
• Specify the specification for option code /Q  
(e.g. /C01)  
NO. OF CHANNELS  
8: 8  
Green in normal operating conditions.  
[1] COMMUNICATION MODE  
S: Single  
W: Dual  
INPUT SPECIFICATIONS  
Narrow Span: -1 – +1 V, 0 – 1 V DC  
Input resistance: 100 kΩ min.  
Wide Span: -10 – +10 V, -5 – +5 V,  
0 – 10 V, 0 – 5 V, 1 – 5 V DC  
[2] OPTIONS (multiple selections)  
Standards & Approvals  
blank: Without CE  
Input resistance: 1 MΩ min.  
/CE: CE marking  
Other Options  
blank: none  
INSTALLATION  
/Q: Option other than the above (specify the specification)  
Operating temperature: -10 to +55°C (14 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: Installation Base (model: R3-BSx)  
Weight: 250 g (0.55 lb)  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
/C03: Rubber coating  
R3-AV8 SPECIFICATIONS  
ES-8436 Rev.7 Page 1/4  
https://www.m-system.co.jp/  
MODEL: R3-AV8  
The alarm output start functioning in the preset time after  
the power has been turned on.  
PERFORMANCE  
Conversion accuracy: Refer to the table at the end of this  
This setting is common to all 8 points.  
ALARM HOLD TIME  
section.  
Conversion rate: 160 / 80 / 40 / 20 msec. selectable  
Data range: 0 – 10000 of the input range  
Data allocation: 4  
(0.0 to 99.0 seconds; factory set to 1.0)  
The alarm output is held for the preset time even if it is  
reset in shorter time.  
Current consumption: 100 mA  
This setting is common to all 8 points.  
Temp. coefficient: ±0.015 % /°C (±0.008 %/°F)  
(±0.03 % /°C [±0.02 %/°F] with 0 – 5 V or 1 – 5 V range)  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1000 V AC @ 1 minute (input 1 to input  
2 to input 3 to input 4 to input 5 to input 6 to input 7 to  
input 8 to internal bus or internal power)  
2000 V AC @ 1 minute (power input to FG; isolated on the  
power supply module)  
Conversion accuracy  
RATE  
160 msec. 80 msec. 40 msec. 20 msec.  
RANGE  
All ranges  
0.1ꢀ  
0.2ꢀ  
0.4ꢀ  
0.8ꢀ  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
RoHS Directive  
ALARM SETTING  
The following parameters are programmable using the PC  
Configurator Software (model: R3CON).  
ALARM TRIP POINT (-15.00 to +115.00 %;  
factory set to A1: 80.00, A2: 60.00, A3: 40.00, A4: 20.00)  
Four alarm setpoints are selectable per each input.  
ALARM TYPE  
(High or Low; factory set to A1: High, A2: High, A3: Low,  
A4: Low)  
High or Low alarm is selectable for each alarm trip point.  
High alarm: An alarm is set when the input signal goes  
above the setpoint.  
Low alarm: An alarm is set when the input signal goes below  
the setpoint.  
DEADBAND (HYSTERESIS)  
(0.00 to 100.00 %; factory set to 5.00)  
Deadband (deviation between the points where the alarm is  
set and reset) is selectable for each alarm trip point.  
ALARM ON DELAY TIME  
(0.0 to 99.0 seconds; factory set to 1.0)  
The alarm output is set when the preset time elapses after  
the input has entered in the alarm range.  
This setting is common to all 8 points.  
POWER ON DELAY TIME  
(0.0 to 99.0 seconds; factory set to 5.0)  
R3-AV8 SPECIFICATIONS  
ES-8436 Rev.7 Page 2/4  
https://www.m-system.co.jp/  
MODEL: R3-AV8  
EXTERNAL VIEW  
SIDE VIEW  
FRONT VIEW  
RUN LED  
ERR LED  
1
2
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
3
4
Functions  
Range  
5
SW1  
SW2  
SW3  
ON  
6
7
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
Conv.  
Rate  
Input 1-4 (SW1)  
or  
Input 5-8 (SW2)  
8
9
10  
11  
12  
13  
14  
ON  
ON  
OUTPUT DATA DESCRIPTIONS  
Four alarm setpoints are selectable per each input. Two (2) word (16 bits × 2) data is transmitterd to the PLC or the host device  
via the R3 network module.  
15  
0
15  
0
0
+1  
Alarm 1  
Alarm 2  
Alarm 3  
Alarm 4  
Alarm 1  
Alarm 2  
Alarm 3  
Alarm 4  
Input 1  
Input 2  
Input 3  
Input 4  
Input 5  
Input 6  
Input 7  
Input 8  
Alarm 1  
Alarm 2  
Alarm 3  
Alarm 4  
Alarm 1  
Alarm 2  
Alarm 3  
Alarm 4  
Alarm 1  
Alarm 2  
Alarm 3  
Alarm 4  
Alarm 1  
Alarm 2  
Alarm 3  
Alarm 4  
Alarm 1  
Alarm 2  
Alarm 3  
Alarm 4  
Alarm 1  
Alarm 2  
Alarm 3  
Alarm 4  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]  
27.5 [1.08]  
109 [4.29]  
POSITIONING  
GUIDE  
1
15  
2
16  
3
17  
4
18  
5
19  
6
28–M3  
SCREW  
20  
7
21  
8
22  
9
23  
10  
24  
11  
25  
12  
26  
13  
27  
14  
28  
TERMINAL  
COVER  
R3-AV8 SPECIFICATIONS  
ES-8436 Rev.7 Page 3/4  
https://www.m-system.co.jp/  
MODEL: R3-AV8  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
RUN LED ERR LED DIP SW  
Input Circuit  
INTERNAL BUS A  
Communication  
Circuit  
1
2
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
INTERNAL BUS B*  
WIDE SPAN  
NARROW SPAN  
INPUT 1  
INPUT 2  
INPUT 3  
INPUT 4  
INPUT 5  
INPUT 6  
INPUT 7  
INPUT 8  
Control  
Circuit  
3
Input Circuit  
Input Circuit  
Input Circuit  
Input Circuit  
Input Circuit  
Input Circuit  
Input Circuit  
INTERNAL POWER  
4
WIDE SPAN  
NARROW SPAN  
5
13  
14  
27  
28  
6
7
WIDE SPAN  
NARROW SPAN  
8
9
10  
11  
12  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
WIDE SPAN  
NARROW SPAN  
WIDE SPAN  
NARROW SPAN  
WIDE SPAN  
NARROW SPAN  
WIDE SPAN  
NARROW SPAN  
WIDE SPAN  
NARROW SPAN  
*For dual redundant communication.  
Note: Connect either wide or narrow span terminals for each channel.  
Specifications are subject to change without notice.  
R3-AV8 SPECIFICATIONS  
ES-8436 Rev.7 Page 4/4  
https://www.m-system.co.jp/  

相关型号:

R3-AV8S/CE

Remote I/O R3 Series DC VOLTAGE INPUT ALARM MODULE
MSYSTEM

R3-AV8S/Q

Remote I/O R3 Series DC VOLTAGE INPUT ALARM MODULE
MSYSTEM

R3-AV8W

Remote I/O R3 Series DC VOLTAGE INPUT ALARM MODULE
MSYSTEM

R3-AV8W/CE

Remote I/O R3 Series DC VOLTAGE INPUT ALARM MODULE
MSYSTEM

R3-AV8W/Q

Remote I/O R3 Series DC VOLTAGE INPUT ALARM MODULE
MSYSTEM

R3-BA32A

Remote I/O R3 Series BCD CODE INPUT MODULE
MSYSTEM

R3-BA32AS

Remote I/O R3 Series BCD CODE INPUT MODULE
MSYSTEM

R3-BA32AS/CE

Remote I/O R3 Series BCD CODE INPUT MODULE
MSYSTEM

R3-BA32AS/Q

Remote I/O R3 Series BCD CODE INPUT MODULE
MSYSTEM

R3-BA32AW

Remote I/O R3 Series BCD CODE INPUT MODULE
MSYSTEM

R3-BA32AW/CE

Remote I/O R3 Series BCD CODE INPUT MODULE
MSYSTEM

R3-BA32AW/Q

Remote I/O R3 Series BCD CODE INPUT MODULE
MSYSTEM