REBS-FF- 概述
Plug-in Signal Conditioners M-UNIT
REBS-FF- 数据手册
通过下载REBS-FF-数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: REBS
3: 0 – 1 V DC (Input resistance 1 MΩ min.)
Plug-in Signal Conditioners M-UNIT
4: 0 – 10 V DC (Input resistance 1 MΩ min.)
5: 0 – 5 V DC (Input resistance 1 MΩ min.)
6: 1 – 5 V DC (Input resistance 1 MΩ min.)
0: Specify voltage (See INPUT SPECIFICATIONS)
RATIO TRANSMITTER
(output bias; isolated)
Functions & Features
• Providing precise matching of DC control signals
to final control elements in open- or closed-loop systems
• Isolation up to 2000 V AC
[2] OUTPUT
Current
A: 4 – 20 mA DC (Load resistance 750 Ω max.)
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)
D: 0 – 20 mA DC (Load resistance 750 Ω max.)
E: 0 – 16 mA DC (Load resistance 900 Ω max.)
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)
Z: Specify current (See OUTPUT SPECIFICATIONS)
Voltage
• Monitor jacks provided for ratio & bias adjustments
• Ratio adjustable from 0.5 to 3.0
• Bias adjustable within ±100 %
• High-density mounting
Typical Applications
• Ratio control for air/fuel flows or for two flows
• Gain calculation for manipulated variable from a controller
• Large scale signal span adjustment
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)
3: 0 – 1 V DC (Load resistance 100 Ω min.)
4: 0 – 10 V DC (Load resistance 1000 Ω min.)
5: 0 – 5 V DC (Load resistance 500 Ω min.)
6: 1 – 5 V DC (Load resistance 500 Ω min.)
4W: -10 – +10 V DC (Load resistance 2000 Ω min.)
5W: -5 – +5 V DC (Load resistance 1000 Ω min.)
0: Specify voltage (See OUTPUT SPECIFICATIONS)
50
(1.97)
80
(3.15)
127
(5)
mm (inch)
[3] POWER INPUT
AC Power
MODEL: REBS–[1][2]–[3][4]
B: 100 V AC
C: 110 V AC
D: 115 V AC
F: 120 V AC
G: 200 V AC
H: 220 V AC
J: 240 V AC
ORDERING INFORMATION
• Code number: REBS-[1][2]-[3][4]
Specify a code from below for each of [1] through [4].
(e.g. REBS-6A-B/Q)
• Special input and output ranges (For codes Z & 0)
• Specify the specification for option code /Q
(e.g. /C01/S01)
DC Power
S: 12 V DC
R: 24 V DC
V: 48 V DC
[1] INPUT
Current
P: 110 V DC
A: 4 – 20 mA DC (Input resistance 250 Ω)
B: 2 – 10 mA DC (Input resistance 500 Ω)
C: 1 – 5 mA DC (Input resistance 1000 Ω)
D: 0 – 20 mA DC (Input resistance 50 Ω)
E: 0 – 16 mA DC (Input resistance 62.5 Ω)
F: 0 – 10 mA DC (Input resistance 100 Ω)
G: 0 – 1 mA DC (Input resistance 1000 Ω)
H: 10 – 50 mA DC (Input resistance 100 Ω)
Z: Specify current (See INPUT SPECIFICATIONS)
Voltage
[4] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
REBS SPECIFICATIONS
ES-3202 Rev.3 Page 1/4
http://www.m-system.co.jp/
MODEL: REBS
/C03: Rubber coating
Operating humidity: 30 to 90 %RH (non-condensing)
TERMINAL SCREW MATERIAL
/S01: Stainless steel
Mounting: Surface or DIN rail
Weight: 300 g (0.66 lb)
GENERAL SPECIFICATIONS
Construction: Plug-in
PERFORMANCE in percentage of span
Setpoint accuracy: ±1.0 % (for monitor output voltage)
Computing accuracy: ±0.5 % (with ratio=1, bias=0 %)
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Response time: ≤ 0.5 sec. (0 – 90 %)
Connection: M3.5 screw terminals
Screw terminal: Chromated steel (standard) or stainless
steel
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
Overrange output: Approx. -10 to +120 % at 1 – 5 V
Ratio adjustment: 0.5 – 3.0 (front)
Bias adjustment: -100 – +100 % (front)
Monitor jack diameter: 2 mm (.08")
Equation: Xo = KXi + B
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute (input to output
to power to ground)
where Xo : output (%)
Xi : input (%)
K : ratio
(linear characteristic; 0.5 – 3.0)
B : bias (-100 – +100 %)
INPUT SPECIFICATIONS
■ DC Current:
Shunt resistor attached to the input terminals (0.5 W)
Specify input resistance value for code Z.
■ DC Voltage: 0 – 300 V DC
Minimum span: 1 V
Offset: Max. 1.5 times span
Input resistance: ≥ 1 MΩ
OUTPUT SPECIFICATIONS
■ DC Current: 0 – 20 mA DC
Minimum span: 1 mA
Offset: Max. 1.5 times span
Load resistance: Output drive 15 V max.
■ DC Voltage: -10 – +12 V DC
Minimum span: 5 mV
Offset: Max. 1.5 times span
Load resistance: Output drive 10 mA max.; 5 mA for
negative voltage output; at ≥ 0.5 V
INSTALLATION
Power input
• AC: Operational voltage range: rating ±10 %,
50/60 ±2 Hz, approx. 2 VA
• DC: Operational voltage range: rating ±10 %, or 85 – 150
V for 110 V rating (ripple 10 % p-p max.)
approx. 2 W (80 mA at 24 V)
Operating temperature: -5 to +60°C (23 to 140°F)
REBS SPECIFICATIONS
ES-3202 Rev.3 Page 2/4
http://www.m-system.co.jp/
MODEL: REBS
EXTERNAL VIEW
Bias Monitor
Ratio Monitor
COM.
Bias Adj.
Ratio Adj.
Front Cover (open)
EXTERNAL DIMENSIONS unit: mm (inch)
CLAMP
(top & bottom)
7.8 (.31)
DIN RAIL
35mm wide
6
5
4
3
2–4.5 (.18) dia.
MTG HOLE
15 (.59) deep
7
8
1
2
8–M3.5
SCREW
50 (1.97)
107 (4.21)
127 (5)
40 (1.57)
50 (1.97)
[3.3 (.13)]
• When mounting, no extra space is needed between units.
TERMINAL ASSIGNMENTS unit: mm (inch)
INPUT RESISTOR
(model: REM)
6
5
4
3
7
8
1
2
Input shunt resistor attached
for current input.
REBS SPECIFICATIONS
ES-3202 Rev.3 Page 3/4
http://www.m-system.co.jp/
MODEL: REBS
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
RATIO
BIAS
Isolation
Ratio
Adjustment
Bias
Adjustment
Output
Driver
+
–
3
4
5
6
1
2
7
8
+
Amplifier
*
INPUT
R
OUTPUT
POWER
–
COM.
U(+)
V(–)
RATIO (R)
BIAS (B)
Ratio / Bias
Monitor
Base Socket
*Input shunt resistor attached for current input.
Specifications are subject to change without notice.
REBS SPECIFICATIONS
ES-3202 Rev.3 Page 4/4
http://www.m-system.co.jp/
REBS-FF- 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
REBS-FF-/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
REBS-FF-B | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
REBS-FF-B/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
REBS-FF-C | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
REBS-FF-C/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
REBS-FF-D | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
REBS-FF-D/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
REBS-FF-G | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
REBS-FF-G/Q | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 | |
REBS-FF-H | MSYSTEM | Plug-in Signal Conditioners M-UNIT | 获取价格 |
REBS-FF- 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8