SES-261-V/E2

更新时间:2024-10-29 22:49:02
品牌:MSYSTEM
描述:Plug-in Signal Conditioners M-UNIT HIGH/LOW SELECTOR

SES-261-V/E2 概述

Plug-in Signal Conditioners M-UNIT HIGH/LOW SELECTOR

SES-261-V/E2 数据手册

通过下载SES-261-V/E2数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
MODEL: SES  
Plug-in Signal Conditioners M-UNIT  
[3] OUTPUT  
Current  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
HIGH/LOW SELECTOR  
(isolated)  
Functions & Features  
• Monitoring two DC input signals and transmitting an  
output signal proportional to the higher or lower input  
• LCD meter indicates the selected input signals  
(engineering unit display selectable)  
• Simple loop test output (0 % and 100 %)  
• Isolation up to 2000 V AC  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 100 Ω min.)  
4: 0 – 10 V DC (Load resistance 1000 Ω min.)  
5: 0 – 5 V DC (Load resistance 500 Ω min.)  
6: 1 – 5 V DC (Load resistance 500 Ω min.)  
4W: -10 – +10 V DC (Load resistance 2000 Ω min.)  
5W: -5 – +5 V DC (Load resistance 1000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
• High-density mounting  
Typical Applications  
• Selecting greater flow, pressure, etc. for control  
• Heating control by multiple T/C’s on a furnace  
50  
(1.97)  
80  
(3.15)  
[4] POWER INPUT  
AC Power  
B: 100 V AC  
127  
(5)  
C: 110 V AC  
mm (inch)  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
MODEL: SES–[1][2][3]–[4][5]  
H: 220 V AC  
J: 240 V AC  
DC Power  
ORDERING INFORMATION  
• Code number: SES-[1][2][3]-[4][5]  
Specify a code from below for each [1] through [5].  
(e.g. SES-1AA-B/E2Q)  
S: 12 V DC  
R: 24 V DC  
V: 48 V DC  
P: 110 V DC (Not selectable with Option /E2.)  
• Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
[5] OPTIONS (multiple selections)  
LCD Meter (after selection)  
blank: Without  
[1] SELECTING FUNCTION  
1: Low input  
/E: With (0.0 - 100.0 % display)  
/E2: With (in engineering unit with backlight and the  
simple loop test output)  
2: High input  
Other Options  
[2] INPUT  
Current  
blank: none  
/Q: Option other than the above (specify the specification)  
A: 4 – 20 mA DC (Input resistance 250 Ω)  
B: 2 – 10 mA DC (Input resistance 500 Ω)  
C: 1 – 5 mA DC (Input resistance 1000 Ω)  
H: 10 – 50 mA DC (Input resistance 100 Ω)  
Voltage  
6: 1 – 5 V DC (Input resistance 1 MΩ min.)  
SES SPECIFICATIONS  
ES-1646 Rev.3 Page 1/4  
http://www.m-system.co.jp/  
MODEL: SES  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
INSTALLATION  
Power input  
AC: Operational voltage range: rating ±10 %, 50/60 ±2 Hz,  
approx. 2 VA  
/C02: Polyurethane coating  
/C03: Rubber coating  
(approx. 3 VA with Option /E2)  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
DC: Operational voltage range: rating ±10 %, or 85 – 150 V  
for 110 V rating ripple 10 %p-p max.  
approx. 2.5 W (110 mA at 24 V; approx. 3.5 W with Option  
/E2)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Operating temperature: -5 to +60°C (23 to 140°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Connection: M3.5 screw terminals  
Screw terminal: Chromated steel (standard) or stainless  
steel  
Weight: 400 g (0.88 lb)  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
Overrange output: Approx. -10 to +120 % at 1 – 5 V  
Selecting operation: Automatic  
PERFORMANCE in percentage of span  
Accuracy: ±0.2 %  
Display accuracy: ± (0.2 % of FS + 1 digit)  
Simple loop test output setting accuracy: ±0.5 %  
Selecting sensitivity: 0.5%  
Simple loop test output: 0 % and 100 % signal simulated by  
selecting the front switch positions. (Only for option code  
/E2)  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Response time: ≤ 0.5 sec. (0 – 90 %)  
■ DISPLAY (LCD meter)  
• Option code: /E  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute (input to output  
to power to ground)  
LCD digital display: 0.0 - 100.0 % (min. digit 0.1 %)  
(No scaling)  
• Option code: /E2  
LCD digital display: Engineering unit  
Display scaling: -10000 – +10000  
Decimal position: 10-1 - 10-4 or no decimal point  
Engineering unit: %, μV, mV, V, mA, A, °C, °F, Ω, DEG K,  
mHz, Hz, kHz, VAC, AAC, mg, g, kg, t, rpm or rps selectable  
Back light: Green at normal, red at loop test output enable  
Factory setting: scaling 0.00 - 100.00, unit: %  
INPUT SPECIFICATIONS  
DC Current:  
Shunt resistor attached to the input terminals (0.5 W)  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
Minimum span: 1 mA  
Offset: Max. 1.5 times span  
Load resistance: Output drive 15 V max.  
DC Voltage: -10 – +12 V DC  
Minimum span: 5 mV  
Offset: Max. 1.5 times span  
Load resistance: Output drive 10 mA max.; 5 mA for  
negative voltage output; at ≥ 0.5 V  
SES SPECIFICATIONS  
ES-1646 Rev.3 Page 2/4  
http://www.m-system.co.jp/  
MODEL: SES  
EXTERNAL VIEW  
OPTION /E2  
LCD Meter  
NEXT Key  
Loop Test Selector  
ENTER Key  
Top  
: 0% fixed  
Middle : 100% fixed  
Bottom : Cancel  
(normal operating mode)  
EXTERNAL DIMENSIONS unit: mm (inch)  
CLAMP  
(top & bottom)  
7.8 (.31)  
DIN RAIL  
35mm wide  
6
5
4
3
2–4.5 (.18) dia.  
MTG HOLE  
15 (.59) deep  
7
8
1
2
8–M3.5  
SCREW  
50 (1.97)  
107 (4.21)  
127 (5)  
40 (1.57)  
50 (1.97)  
[3.3 (.13)]  
• When mounting, no extra space is needed between units.  
TERMINAL ASSIGNMENTS unit: mm (inch)  
INPUT RESISTOR  
(model: REM)  
6
5
4
3
7
8
1
2
Input shunt resistor attached  
for current input.  
SES SPECIFICATIONS  
ES-1646 Rev.3 Page 3/4  
http://www.m-system.co.jp/  
MODEL: SES  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
**  
Isolation  
Output  
Driver  
+
+
+
Selector  
1
2
3
4
5
6
*
*
INPUT 1  
INPUT 2  
R
R
OUTPUT  
POWER  
***  
LOOP TEST  
SELECTOR  
U(+)  
V(–)  
7
8
Base Socket  
*
Input shunt resistor attached for current inputs.  
** Option /E, E2  
*** Option /E2  
Specifications are subject to change without notice.  
SES SPECIFICATIONS  
ES-1646 Rev.3 Page 4/4  
http://www.m-system.co.jp/  

SES-261-V/E2 相关器件

型号 制造商 描述 价格 文档
SES-261-V/Q MSYSTEM Plug-in Signal Conditioners M-UNIT HIGH/LOW SELECTOR 获取价格
SES-262-B MSYSTEM Plug-in Signal Conditioners M-UNIT HIGH/LOW SELECTOR 获取价格
SES-262-B/E MSYSTEM Plug-in Signal Conditioners M-UNIT HIGH/LOW SELECTOR 获取价格
SES-262-B/E2 MSYSTEM Plug-in Signal Conditioners M-UNIT HIGH/LOW SELECTOR 获取价格
SES-262-B/Q MSYSTEM Plug-in Signal Conditioners M-UNIT HIGH/LOW SELECTOR 获取价格
SES-262-C MSYSTEM Plug-in Signal Conditioners M-UNIT HIGH/LOW SELECTOR 获取价格
SES-262-C/E MSYSTEM Plug-in Signal Conditioners M-UNIT HIGH/LOW SELECTOR 获取价格
SES-262-C/E2 MSYSTEM Plug-in Signal Conditioners M-UNIT HIGH/LOW SELECTOR 获取价格
SES-262-C/Q MSYSTEM Plug-in Signal Conditioners M-UNIT HIGH/LOW SELECTOR 获取价格
SES-262-H MSYSTEM Plug-in Signal Conditioners M-UNIT HIGH/LOW SELECTOR 获取价格

SES-261-V/E2 相关文章

  • HARTING(浩亭)圆形连接器产品选型手册
    2024-10-31
    6
  • HYCON(宏康科技)产品选型手册
    2024-10-31
    6
  • GREEGOO整流二极管和晶闸管产品选型手册
    2024-10-31
    7
  • 西门子豪掷106亿美元,战略收购工程软件巨头Altair
    2024-10-31
    8