TC10NM-V-M2 [MSYSTEM]
Temperature Controller TC10 Series;型号: | TC10NM-V-M2 |
厂家: | M-SYSTEM |
描述: | Temperature Controller TC10 Series |
文件: | 总7页 (文件大小:222K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: TC10NM
Temperature Controller TC10 Series
RELATED PRODUCTS
• PC configurator software (model: TC10CFG)
Downloadable at M-System’s web site.
TEMPERATURE CONTROLLER
(Modbus, 5 digit, LED display type, size 48 x 96 mm)
Functions & Features
A dedicated cable is required to connect the module to the
PC. Please refer to the internet software download site or
the users manual for the PC configurator for applicable
cable types.
• One PID controller
• Universal input x 1 point, control output x 4 points,
discrete input x 2 points, clamp-on current sensor input x 1
point
• Clamp-on current sensor (model: CLSE)
(Used for detecting the heater wire break)
• Universal input configurable to T/C, RTD, DC current or
voltage independently
GENERAL SPECIFICATIONS
Construction: Panel flush mounting
• Discrete inputs usable to switch PID bank or operation
mode
Degree of protection: IP65; applicable to the front panel of
the unit with single mounting according to the specified
panel cutout
• Control outputs configurable to MV, PV or alarm
• Clamp-on current sensor input enables to detect heater
wire break or over current
Configuration jack: 2.5 dia. miniature jack connector;
RS-232-C level (bottom of the unit)
• Auto tuning function
Connection: M3 separable screw terminal (torque 0.5 N·m)
Solderless terminal: Refer to the drawing at the end of the
section.
48(1.89)
Recommended manufacturer: Japan Solderless Terminal
MFG.Co.Ltd, Nichifu Co.,ltd
Applicable wire size: 0.25 to 1.65 mm
2
(AWG 22 to 16)
96(3.8)
Screw terminal: Nickel-plated steel
Housing material: Flame-resistant resin (gray)
Isolation: Pv1 to CT1 to Di1 or Di2 to MV1 to MV2 to Do1 or
Do2 to Modbus to power
108(4.25)
mm (inch)
CT Input waveform
RMS sensing: Up to 15 % of 3rd harmonic content
Control mode: Standard PID, heating and cooling control
(ON/OFF, PID)
MODEL: TC10NM–[1]–M2
Proportional band (P): 0.1 to 3200.0 (temperature unit)
Integral time (I): 0 to 3999 sec.
Derivative time (D): 0.0 to 999.9 sec.
Auto-tuning: Limit cycle method
Alarm: Deviation high & low, absolute high & low, etc.
Sampling cycle: 100 msec.
ORDERING INFORMATION
• Code number: TC10NM-[1]-M2
Specify a code from below for [1].
(e.g. TC10NM-A-M2)
Control cycle: 1.0 to 99.9 sec.
[1] CONTROL OUTPUT
A: 0 – 20 mA DC (Load resistance 500 Ω max.)
Open-collector 2 points
(100 msec. fixed for Mv output 0 - 20 mA DC
and 0 - 10 V DC)
Mv output range: -5 - +105 % for output scale
Parameters: Stored in non-volatile memory; write/erase
cycle endurance: less than 1 000 000
Parameter setting: With front panel operation buttons or PC
configurator software (model: TC10CFG)
• Universal input
V: 0 – 10 V DC (Load resistance 2 kΩ max.)
Open-collector 2 points
P: 12 V pulse (Load resistance 600 Ω max.)
Open-collector 2 points
POWER INPUT
AC Power
• Burnout on/off
• Control output
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
• Bank
• Event input
• CT input
• Auto-tuning
TC10NM SPECIFICATIONS
ES-9582 Rev.3 Page 1/7
http://www.m-system.co.jp/
MODEL: TC10NM
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,
Refer to the instruction manual for detail.
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,
■Recommended solderless terminal
cm, mm, m, m/sec, mm/min, cm/min, m/min,
m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m3, m3/sec,
3.3 (.13) max
m3
/min, m
3
/h, Nm /h, N·m, N/m , g, kg, kg/h,
3
2
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,
kJ, MJ, rpm, sec, min, min-1, pH, %, ppm, etc.
mm (inch)
INPUT SPECIFICATIONS
■ Universal input (Pv1)
MODBUS COMMUNICATION
Communication: Half-duplex, asynchronous, no procedure
Standard: Conforms to TIA/EIA-485-A
Transmission distance: 500 meters max.
Transmission media: Shielded twisted-pair cable
(CPEV-S 0.9 dia.)
For type and range configuration, refer to the instruction
manual.
DC Current:
Input range: 0 - 20 mA DC
Input resistance: 49.9 Ω resistor incorporated
• DC voltage input
Node adress: 1 to 247
Input resistance: ≥ 10 kΩ (-1000 to +1000 mV DC)
Input resistance: ≥ 1 MΩ (-10 to +10 V DC)
• Thermocouple
Data mode: RTU (Binary)
Parity: None, even or odd
Baud rate: 4800, 9600, 19.2 k, 38.4 k, 57.6 k (bps)
Stop bit: 1 or 2
Input resistance: ≥ 10 kΩ
Input range: Refer to the table 1
Burnout sensing: ≤ 4 μA
Node adress, parity, baud rate setting: With front panel
operation buttons or PC configurator software (model:
TC10CFG)
Conformance range: Refer to the table 1
• RTD (2-wire or 3-wire)
Terminating resistor: Built-in (Enable by shorting between
pin 3 and 4)
Excitation: ≤ 0.33 mA
Input range: Refer to the table 1
Allowable leadwire resistance: 20 Ω per wire
• Resistor (2-wire or 3-wire)
Excitation: ≤ 0.33 mA
DISPLAY
PV display: 5 digits 7-segment green LED, 10.2 mm (.40”)
height
Input range: 0 - 4000 Ω
SP display: 5 digits 7-segment red LED, 8.2 mm (.32”)
height, switchable to MV display
Allowable leadwire resistance: 20 Ω per wire
• Potentiometer
Display range: -32000 to 32000
Excitation: ≤ 0.33 mA
Decimal point position: 10–1 to 10–4 or none
Zero indication: Higher-digit zeros are suppressed.
Loop status indicators
Input range: 0 to 4000 Ω
Allowable leadwire resistance: 20 Ω per wire
■ Clamp-on current sensor (CT1)
(Sensor model No.: AC input)
CLSE-R5: 0 – 5 A
Bank1: Green LED turns on when bank 1 chosen
Bank2: Green LED turns on when bank 2 chosen
Bank3: Green LED turns on when bank 3 chosen
Bank4: Green LED turns on when bank 4 chosen
Alarm1: Red LED turns on at alarm 1
Alarm2: Red LED turns on at alarm 2
Alarm3: Red LED turns on at alarm 3
Alarm4: Red LED turns on while setting is saving to the
non-volatile memory.
CLSE-05: 0 – 50 A
CLSE-10: 0 – 100 A
CLSE-20: 0 – 200 A
CLSE-40: 0 – 400 A
CLSE-60: 0 – 600 A
Frequency: 50 / 60 Hz (45 - 65 Hz)
Max. working voltage: 480 V AC (primary side)
Overload capacity:
Run: Green LED turns on while loop is in operation.
Man: Green LED turns on during manual mode
Local: Unused, off
CLSE-R5: 10 A continuous, x40 (1 sec.)
CLSE-05: 60 A continuous, x40 (1 sec.)
CLSE-10: 120 A continuous, x40 (1 sec.)
CLSE-20: 240 A continuous, x40 (1 sec.)
CLSE-40: 480 A continuous, x40 (1 sec.)
CLSE-60: 720 A continuous, x40 (1 sec.)
At: Green LED turns on during auto-tuning
Out1: Green LED turns on when MV1 output
Out2: Green LED turns on when MV2 output
Engineering unit indication: Sticker label attached
TC10NM SPECIFICATIONS
ES-9582 Rev.3 Page 2/7
http://www.m-system.co.jp/
MODEL: TC10NM
Operational range
Mounting: Panel flush mounting
CLSE-R5: ≤ 5 A
Weight: 300 g (0.66 lb)
CLSE-05: ≤ 50 A
CLSE-10: ≤ 100 A
PERFORMANCE in percentage of span
Accuracy
CLSE-20: ≤ 200 A
CLSE-40: ≤ 400 A
• Pv1: Refer to "Input type, range & conversion accuracy"
section.
CLSE-60: ≤ 600 A
Caution 1: The output values may vary depending on the
accuracy of engagement at the clamp connection.
Caution 2: The sensor’s mechanical construction may cause
it to generate resonance sound. However, it does not affect
the perfomrance of the sensor.
■ Discrete Input (Di1, Di2)
• CT1: ±2 % (sensor error margin not included)
• MV1 or MV2: ±0.5 % (added to the input accuracy)
Cold junction compensation error (thermocouple input):
±2.0°C at -10 – 55°C (±3.6°F at 14 – 131°F)
CJC sensor is adjacently attached to the input terminals.
Temp. coefficient
Contact rating: 3.3 V @ 0.33 mA
Detection levels:
• Pv1: ±0.03 %/°C (± 0.02 %/°F)
• CT1: ±0.03 %/°C (± 0.02 %/°F)
≤ 1.6 kΩ / 0.5 V at close
Response time
≥ 30 kΩ / 2.5 V at open
• CT1: ≤ 2 sec. (0 – 90 %)
• Mv1 or Mv2: ≤ 1 sec. (0 – 90 %, DC output)
Burnout response (thermocouple, RTD, resistor,
potentiometer input): ≤ 10 s
OUTPUT SPECIFICATIONS
Four control outputs are configurable to Mv, Ao or Do.
■ Control Output (Mv1, Mv2)
Specify one type of output with the code number from 3
types shown below.
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute (Pv1 to CT1 to Di1
or Di2 to MV1 to MV2 to Do1 or Do2 to Modbus to power to
ground)
• DC Current: 0 – 20 mA DC
Operational range: 0 – 23 mA DC
Load resistance: ≤ 500 Ω
STANDARDS & APPROVALS
EU conformity:
• DC Voltage: 0 – 10 V DC
Operational range: 0 - 11.5 V DC
Load resistance: ≥ 2 kΩ
EMC Directive
EMI EN 61000-6-4
• 12 V Voltage pulse
EMS EN 61000-6-2
Maximum frequency: 1 Hz
Low Voltage Directive
Minimum pulse width: 1 msec.
Hi level: 12 V ±15 %
EN 61010-1
Installation Category II
Lo level: ≤ 0.5 V
Pollution Degree 2
Load resistance: 600 Ω min.
■ Control Output (Do1, Do2)
• Open collector
Input or output or Modbus to power – Reinforced insulation
(300 V)
Input to output to Modbus – Basic insulation (300 V)
Maximum frequency: 1 Hz
RoHS Directive
EN 50581
Minimum pulse width: 1 msec.
Output rating: 50 V DC 100 mA (resistive load)
Saturation voltage: 0.5 V DC
INSTALLATION
Power Consumption
•AC:
Approx. 6 VA at 100 V
Approx. 7 VA at 200 V
Approx. 8 VA at 240 V
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 5 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
TC10NM SPECIFICATIONS
ES-9582 Rev.3 Page 3/7
http://www.m-system.co.jp/
MODEL: TC10NM
INPUT TYPE, RANGE & CONVERSION ACCURACY
INPUT TYPE
INPUT RANGE
0 to 20mA DC
ACCURACY
DC CURRENT
DC VOLTAGE
±20ꢀA
-1000 to +1000mV DC
When max. range*2 is ≥60mV ±20ꢀV
When max. range*2 is ≤120mV ±±0ꢀV
When max. range*2 is ≥120mV ±200ꢀV
±10mV ±0.1ꢁ
-10 to +10V DC
Total resistance up to 4000Ω*±
0 to 4000Ω
POTENTIOMETER
RESISTOR
±0.1Ω or ±0.1ꢁꢂ ,hicheꢃer is greater
±0.1Ω or ±0.1ꢁꢂ ,hicheꢃer is greater
°C
INPUT RANGE ACCURACY
F
゜
Thermocouple
*1
*1
CONFORMANCE RANGE
0 to 1760
INPUT RANGE ACCURACY
CONFORMANCE RANGE
ꢀ (PR)
0 to 1760
-270 to +1±70
-270 to +1000
-210 to +1200
-270 to +400
100 to 1ꢄ20
-50 to +1760
-50 to +1760
0 to 2±15
±1.ꢄ0
±0.40
±0.60
±0.70
±0.50
±2.00
±1.00
±1.00
±1.00
±0.50
±0.50
±0.±0
±0.±0
°C
±2 to ±200
-454 to +249ꢄ
-454 to +1ꢄ±2
-±46 to +2192
-454 to +752
212 to ±±0ꢄ
-5ꢄ to +±200
-5ꢄ to +±200
±2 to 4199
±±.24
±0.72
±1.0ꢄ
±1.26
±0.90
±±.60
±1.ꢄ0
±1.ꢄ0
±1.ꢄ0
±0.90
±0.90
±0.54
±0.54
±2 to ±200
-2±ꢄ to +249ꢄ
-274 to +1ꢄ±2
-292 to +2192
-274 to +752
752 to ±200
±92 to ±200
±2 to ±200
K (CA)
-150 to +1±70
-170 to +1000
-1ꢄ0 to +1200
-170 to +400
400 to 1760
200 to 1760
0 to 1760
E (CRC)
J (IC)
T (CC)
B (RH)
R
S
C (WRe 5-26)
0 to 2±15
±2 to 4199
N
-270 to +1±00
-200 to +600
-200 to +900
0 to 1±95
-1±0 to +1±00
-200 to +600
-200 to +900
0 to 1±95
-454 to +2±72
-±2ꢄ to +1112
-±2ꢄ to +1652
±2 to 254±
-202 to +2±72
-±2ꢄ to +1112
-±2ꢄ to +1652
±2 to 254±
U
L
P (Platinel ll)
F
゜
RTD
INPUT RANGE
-200 to +ꢄ50
-200 to +ꢄ50
-200 to +ꢄ50
-200 to +649
-200 to +510
-50 to +200
ACCURACY
±0.40
INPUT RANGE
ACCURACY
±0.72
Pt 100 (JIS ’97ꢂ IEC)
Pt 500
-±2ꢄ to +1562
-±2ꢄ to +1562
-±2ꢄ to +1562
-±2ꢄ to +1200
-±2ꢄ to +950
-5ꢄ to +±92
±0.40
±0.72
Pt 1000
±0.40
±0.72
Pt 50Ω (JIS‘ꢄ1)
JPt 100 (JIS’ꢄ9)
Ni 50ꢄ.4Ω
±0.60
±1.0ꢄ
±0.40
±0.72
±0.60
±1.0ꢄ
Cu 10 (25℃)
-50 to +250
±2.00
-5ꢄ to +4ꢄ2
±±.60
*1.Thermocouple: Add 2.0°C of cold-junction-compensation error.
*2. Max. range: absolute range (greater of 0ꢁ and 100ꢁ range ꢃalues)ꢂ ,hicheꢃer is greater.
*±. Refer to the operating manual for details.
EXTERNAL VIEW
■ FRONT VIEW
■ BOTTOM VIEW
Loop
status indicators
PV Display
SP/MV Display
SP/MV
Esc
Configuration Jack
Operation Buttons
TC10NM SPECIFICATIONS
ES-9582 Rev.3 Page 4/7
http://www.m-system.co.jp/
MODEL: TC10NM
COMMUNICATION CABLE CONNECTIONS
■ MASTER CONNECTION
HOST PC
TX+/RX+
TX–/RX–
SG
TC10NM
DA
TC10NM
DA
TERMINATOR
*1
NO.
ID
FUNCTION
DB
DB
4
5
DA
DB
DA
DB
RX+
RX–
*1. For using internal terminator, short-accross terminals 3 and 4.
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
4 – M3 Screw
20 – M3 Terminal Screw
Watertight Sealing
Terminal Cover
Mounting Bracket
1
2
11
12
13
14
15
16
17
18
19
20
3
4
5
6
7
8
9
10
2 (.08)
48(1.89)
45(1.77)
8 (.31)
98 (3.86)
100 (3.93)
■ PANEL CUTOUT unit: mm (inch)
45 +−00.8
Pitch ≥75 (2.95)
Mounting bracket: 0.5 – 10 (0.02 to 0.39)
TC10NM SPECIFICATIONS
ES-9582 Rev.3 Page 5/7
http://www.m-system.co.jp/
MODEL: TC10NM
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Indicator LEDs
3
...
Isolation
TERMINATOR
MODBUS
Isolation
4
5
DA
DB
11
Comm.
Circuit
Pv1
A/D
Converter
12
13
UNIVERSAL INPUT
Isolation
Isolation
Isolation
16
17
+
–
Output
Circuit
Mv1
Mv2
Isolation
Isolation
Control
Circuit
14
15
6
7
+
–
Output
Circuit
CT1
A/D
Converter
18
19
20
1
+
+
–
U
V
8
9
Output
Circuit
Do1
Input
Circuit
Do2
Di1
Di2
Display/
Setting
10
POWER
2
CONFIG.JACK
■ CONTROL OUTPUT 1 CONNECTION e.g.
■ UNIVERSAL INPUT CONNECTION (Pv1) e.g. ■ CT1 CONNECTION e.g.
• DC Current (0 – 20mA DC)
• DC Voltage (-1000 – +1000mV DC)
• DC Voltage (-10 – +10V DC)
• Clamp-on Current Sensor (model : CLSE)
16
17
+
–
Mv1
k
+
11
12
13
14
INPUT
15
l
■ CONTROL OUTPUT 2 CONNECTION e.g.
–
Load Side
• Thermocouple
6
7
+
–
■ DISCRETE INPUT CONNECTION e.g.
Mv2
–
–
• Mechanical Contact
11
12
13
CJC
+
Di1
SENSOR
8
9
■ CONTROL OUTPUT 3 & 4 CONNECTION e.g.
Di2
+
Do1
comp. leadwire
+
–
18
19
Do2
10
+
–
• RTD/Resistor (3-wire)
• Open Collector
20
A
B
B
11
+
+
–
Di1
12
13
8
9
Di2
10
• RTD/Resistor (2-wire)
A
B
11
12
13
• Potentiometer
max.
+
–
11
12
13
min.
TC10NM SPECIFICATIONS
ES-9582 Rev.3 Page 6/7
http://www.m-system.co.jp/
MODEL: TC10NM
Specifications are subject to change without notice.
TC10NM SPECIFICATIONS
ES-9582 Rev.3 Page 7/7
http://www.m-system.co.jp/
相关型号:
TC10V.TB
Zener Diode, 10V V(Z), 5%, 0.5W, Silicon, Unidirectional, DO-35, HERMETIC SEALED, GLASS PACKAGE-2
TAK_CHEONG
TC10V.TR
Zener Diode, 10V V(Z), 5%, 0.5W, Silicon, Unidirectional, DO-35, HERMETIC SEALED, GLASS PACKAGE-2
TAK_CHEONG
TC10VB
Zener Diode, 10V V(Z), 2%, 0.2W, Silicon, Unidirectional, ROHS COMPLIANT, PLASTIC, SIMILAR TO SC-90, 2 PIN
TAK_CHEONG
TC10VC
Zener Diode, 10V V(Z), 5%, 0.2W, Silicon, Unidirectional, ROHS COMPLIANT, PLASTIC, SIMILAR TO SC-90, 2 PIN
TAK_CHEONG
©2020 ICPDF网 联系我们和版权申明