W2MST-C6-R/N [MSYSTEM]

Space-saving Dual Output Signal Conditioners Mini-MW Series;
W2MST-C6-R/N
型号: W2MST-C6-R/N
厂家: M-SYSTEM    M-SYSTEM
描述:

Space-saving Dual Output Signal Conditioners Mini-MW Series

文件: 总3页 (文件大小:113K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: W2MST  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
Space-saving Dual Output Signal Conditioners  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
Mini-MW Series  
2-OUTPUT PARAMETER GENERATOR  
Functions & Features  
• Provides a constant DC signal  
• Setpoint adjustable from -10.0 to +105 %  
• Easy setting with the front digital display  
[2] OUTPUT 2  
Y: None  
Typical Applications  
• Various parameter settings for computers and  
DCS’s  
Current  
A: 4 – 20 mA DC (Load resistance 350 Ω max.)  
Voltage  
29.5 (1.16)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
[3] POWER INPUT  
MODEL  
AC Power  
88.5  
(3.48)  
HI  
UP  
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,  
LO  
DOWN  
47 – 66 Hz)  
ZE  
SP  
RO  
AN  
DC Power  
124  
(4.88)  
ZE  
RO  
R: 24 V DC  
SP  
AN  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
R2: 11 – 27 V DC  
mm (inch)  
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)  
P: 110 V DC  
MODEL: W2MST–[1][2]–[3][4]  
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
ORDERING INFORMATION  
• Code number: W2MST-[1][2]-[3][4]  
Specify a code from below for each of [1] through [4].  
(e.g. W2MST-AA-M2/N/Q)  
[4] OPTIONS (multiple selections)  
Standards & Approvals (must be specified)  
/N: Without CE  
Other Options  
• Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
blank: none  
/Q: Option other than the above (specify the specification)  
Note: When the user requires a current and a voltage  
output, specify the current to be the Output 1 which allows  
a greater load.  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
[1] OUTPUT 1  
Current  
/C03: Rubber coating  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection: M3 screw terminals (torque 0.8 N·m)  
Screw terminal: Chromated steel (standard) or stainless  
steel  
Housing material: Flame-resistant resin (black)  
Isolation: Output 1 to output 2 to power  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
W2MST SPECIFICATIONS  
ES-5517 Rev.1 Page 1/3  
http://www.m-system.co.jp/  
MODEL: W2MST  
Overrange output: Approx. -10 to +105 % (within 0 to 20  
mA DC, -10 to +12 V DC)  
EXTERNAL VIEW  
Zero adjustment: -5 to +5 % (front)  
(A) Polarity Indicator LED  
(B) Setpoint Display  
MODEL  
RED  
(+)  
GREEN  
Span adjustment: 95 to 105 % (front)  
(-)  
Adjustable individually for each output 1 and output 2.  
Setpoint adjustment: -10.0 – +105 %;  
HI  
UP  
(C) Display Selector  
LO  
DOWN  
Top: ON  
Bottom: OFF  
0.1 % increments (1 % increments over 100 %)  
Display selector: Double-throw SW (front)  
UP/DOWN control: Double-throw, momentary SW (front)  
INDICATORS  
ZERO  
OUT1  
SPAN  
(D) UP/DOWN Control  
ZERO  
OUT2  
SPAN  
Setpoint display: Red LED; 6.4 mm (.25”) 7 segment, 3  
digits  
(E) Zero Adj.  
Output 1  
(F) Span Adj.  
Polarity indicator: Dual color (red/green) LED; Red with a  
positive set value; Green with a negative set value.  
Power saving mode: Indicators turn off when the switches  
are left untouched for 1 minute, or when the display  
selector is set to the bottom position.  
(G) Zero Adj.  
Output 2  
(H) Span Adj.  
• How to Set an Output  
Turn the Display Selector (C) to the top position.  
The Setpoint Display (B) shows the current setpoint (-10.0 –  
+105 %). Press UP/DOWN Control (D) until the display  
shows a desired set value.  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
Minimum span: 1 mA  
Offset: Max. 1.5 times span  
The Polarity Indicator LED (A) is red when the set value is in  
positive range, green when in negative range.  
Load resistance: Output drive 15 V max.  
DC Voltage: -10 – +12 V DC  
Minimum span: 5 mV  
Offset: Max. 1.5 times span  
Load resistance: Output drive 1 mA max.; at ≥ 0.5 V  
INSTALLATION  
Power Consumption  
AC:  
Approx. 4 VA at 100 V  
Approx. 5 VA at 200 V  
Approx. 6 VA at 264 V  
DC: Approx. 3 W  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 150 g (0.33 lb)  
PERFORMANCE in percentage of span  
Setting accuracy: ±0.1 %  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute (output 1 to  
output 2 to power to ground)  
W2MST SPECIFICATIONS  
ES-5517 Rev.1 Page 2/3  
http://www.m-system.co.jp/  
MODEL: W2MST  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
6 (.23)  
DIN RAIL  
35mm wide  
3
2
5
1
4
6
24.2x5  
(.17x.20)  
MTG HOLE  
6 (.24) deep  
9
8
7
11M3  
SCREW  
11 10  
22 (.87)  
29.5 (1.16)  
21.5 (.87) 10 (.39)  
84 (3.31)  
114 (4.49)  
[4 (.16)]  
• When mounting, no extra space is needed between units.  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
DISPLAY  
SELECTOR  
UP/DOWN  
CONTROL  
Z
S
Isolation  
Digital  
Computation  
Output  
Driver  
1
2
4
5
9
7
8
+
OUTPUT 1  
Z
S
Setpoint  
Display  
Output  
Driver  
3
6
+
OUTPUT 2  
POWER  
10  
11  
U(+)  
V(–)  
Base Socket  
Note: The section enclosed by broken line is only with 2nd output option.  
Specifications are subject to change without notice.  
W2MST SPECIFICATIONS  
ES-5517 Rev.1 Page 3/3  
http://www.m-system.co.jp/  

相关型号:

W2MST-C6-R/Q

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2MST-C6-R2

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2MST-C6-R2/N

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2MST-C6-R2/Q

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2MST-CA-M2

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2MST-CA-M2/N

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2MST-CA-M2/Q

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2MST-CA-P

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2MST-CA-P/N

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2MST-CA-P/Q

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2MST-CA-R

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2MST-CA-R/N

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM