W2PP-121N-R/CE

更新时间:2024-10-29 22:38:26
品牌:MSYSTEM
描述:Space-saving Dual Output Signal Conditioners Mini-MW Series

W2PP-121N-R/CE 概述

Space-saving Dual Output Signal Conditioners Mini-MW Series

W2PP-121N-R/CE 数据手册

通过下载W2PP-121N-R/CE数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
MODEL: W2PP  
(When the low frequency open collector or the dry  
Space-saving Dual Output Signal Conditioners  
contact AC/DC switch is selected as one of the outputs,  
the frequency of the other output is limited to max. 30 Hz.)  
4: 12 V pulse (max. frequency 10 kHz)  
Mini-MW Series  
PULSE ISOLATOR  
Functions & Features  
(When the low frequency open collector or the dry  
contact AC/DC switch is selected as one of the outputs,  
the frequency of the other output is limited to max. 30 Hz.)  
5: 24 V pulse (max. frequency 10 kHz)  
• Galvanically isolates pulse rate signals  
• Input frequency = output frequency  
• Various outputs (open collector, voltage pulses and dry  
contact AC/DC switch)  
(When the low frequency open collector or the dry  
contact AC/DC switch is selected as one of the outputs,  
the frequency of the other output is limited to max. 30 Hz.)  
6: Dry contact AC/DC switch (max. frequency 30 Hz)  
• High-density mounting  
Typical Applications  
• Isolating field pulse signals in order to reduce noises  
• Changing e.g. dry contact signal to e.g. 5 V signals  
[3] OUTPUT 2  
Same range availability as Output 1  
Y: None  
29.5 (1.16)  
[4] OUTPUT LOGIC  
N: The same as the input  
R: Inverted  
Model  
88.5  
(3.48)  
[5] POWER INPUT  
AC Power  
124  
(4.88)  
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,  
mm (inch)  
47 – 66 Hz)  
DC Power  
R: 24 V DC  
MODEL: W2PP–[1][2][3][4]-[5][6]  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
R2: 11 – 27 V DC  
ORDERING INFORMATION  
• Code number: W2PP-[1][2][3][4]-[5][6]  
Specify a code from below for each of [1] through [6].  
(e.g. W2PP-333N-M2/CE/Q)  
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)  
(Select ‘/N’ for ‘Standards & Approvals’ code.)  
P: 110 V DC  
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
[6] OPTIONS (multiple selections)  
Standards & Approvals (must be specified)  
/N: Without CE  
[1] INPUT  
/CE: CE marking  
1: Mechanical contact (max. 30 Hz)  
2: Open collector (max. 10 kHz)  
3: Voltage pulse (max. 10 kHz)  
9: Clamp-on pulse sensor CLSP  
Other Options  
blank: none  
/Q: Option other than the above (specify the specification)  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
[2] OUTPUT 1  
1: Low frequency open collector (max. 30 Hz)  
2: High frequency open collector (max. 10 kHz)  
(When the low frequency open collector or the dry  
contact AC/DC switch is selected as one of the outputs,  
the frequency of the other output is limited to max. 30 Hz.)  
3: 5 V pulse (max. frequency 10 kHz)  
/C02: Polyurethane coating  
/C03: Rubber coating  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
W2PP SPECIFICATIONS  
ES-5534 Rev.12 Page 1/4  
http://www.m-system.co.jp/  
MODEL: W2PP  
AC/DC switch is selected as one of the outputs, the timer is  
applied also to the other output.)  
Saturation voltage: 0.5 V DC  
RELATED PRODUCTS  
• Clamp-on pulse sensor (model: CLSP)  
High Frequency Open Collector:  
50 V DC @100 mA (resistive load)  
Maximum frequency: 10 kHz  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection: M3 screw terminals (torque 0.8 N·m)  
Screw terminal: Chromated steel (standard) or stainless  
steel  
Saturation voltage: 0.5 V DC  
Voltage Pulse  
Maximum frequency: 10 kHz  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output 1 to output 2 to power  
Frequency range: Input and output are the same.  
Chattering protection: Filter provided for mechanical  
contact input  
High level: Rating (5, 12 or 24 V) ±10 %  
Low level: ≤ 0.5V  
Load resistance:  
≥ 250 Ω for 5 V  
≥ 600 Ω for 12 V  
Input pulse sensing: DC coupled  
≥ 1200 Ω for 24 V, output 1  
≥ 2400 Ω for 24 V, output 2  
Dry Contact AC/DC Switch  
INPUT SPECIFICATIONS  
Excitation: 12 V DC @30 mA; shortcircuit protection  
Open Collector  
132 V AC @200 mA (cos ø = 1)  
30 V DC @200 mA (resistive load)  
Maximum frequency: 30 Hz  
Maximum frequency: 10 kHz  
Timer: Limits within 75 ±25 msec.  
for wider than 75 msec. pulses  
ON time for output logic non-inverted  
OFF time for output logic inverted  
(When the low frequency open collector or the dry contact  
AC/DC switch is selected as one of the outputs, the timer is  
applied also to the other output.)  
Saturation voltage: 3 V DC  
Pulse width time requirement: 10 μsec. min. for ON and OFF  
Sensing: Approx. 12 V DC @3 mA  
ON/OFF level: ≤ 600 Ω / 1.8 V for ON, ≥ 100 kΩ / 3.5 V for  
OFF  
Mechanical Contact  
Maximum frequency: 30 Hz  
Pulse width time requirement: 10 msec. min. for ON and  
OFF  
Sensing: Approx. 12 V DC @3 mA  
ON/OFF level: ≤ 200 Ω / 0.6 V for ON, ≥ 100 kΩ / 2.5 V for  
OFF  
INSTALLATION  
Power Consumption  
Voltage Pulse  
AC:  
Maximum frequency: 10 kHz  
Approx. 4 VA at 100 V  
Pulse width time requirement: 10 μsec. min. for high and  
low levels  
Approx. 5 VA at 200 V  
Approx. 6 VA at 240 V  
Waveforms: Square or sine  
DC: Approx. 4 W  
Hi/Lo level: 2 – 50 V for high level; ≤1 V for low level  
Input impedance: 10 kΩ min.  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 200 g (0.44 lb)  
Clamp-on Pulse Sensor CLSP  
Maximum frequency: 50 000 pulses/hour  
ON/OFF level: ≤ 400 Ω / 1.3 V for ON, ≥ 200 kΩ / 12 V for  
OFF  
PERFORMANCE  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute (input to output  
1 to output 2 to power to ground)  
OUTPUT SPECIFICATIONS  
Low Frequency Open Collector:  
50 V DC @100 mA (resistive load)  
Maximum frequency: 30 Hz  
STANDARDS & APPROVALS  
EU conformity:  
Timer: Limits within 75 ±25 msec.  
for wider than 75 msec. pulses  
EMC Directive  
ON time for output logic non-inverted  
OFF time for output logic inverted  
(When the low frequency open collector or the dry contact  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
W2PP SPECIFICATIONS  
ES-5534 Rev.12 Page 2/4  
http://www.m-system.co.jp/  
MODEL: W2PP  
Low Voltage Directive  
EN 61010-1  
Measurement Category II (output)  
Installation Category II (power)  
Pollution Degree 2  
Input or output 1 or output 2 to power input:  
Reinforced insulation (300 V)  
Input to output 1 to output 2: Basic insulation (300 V)  
RoHS Directive  
EN 50581  
OUTPUT LOGIC  
VOLTAGE PULSE  
OUTPUT  
OPEN COLLECTOR  
DRY CONTACT AC/DC SW OUT  
INPUT TYPE  
PULSE LOGIC  
Non Inverted  
INPUT PULSE  
H
H
OFF  
L
L
ON  
Voltage Pulse  
H
H
OFF  
Inverted  
Non Inverted  
Inverted  
L
L
ON  
OFF  
H
OFF  
Mechanical Contact  
Open Collector  
ON  
L
ON  
Clamp-on Pulse  
Sensor CLSP  
OFF  
H
OFF  
ON  
L
ON  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
6 (.23)  
DIN RAIL  
35mm wide  
3
2
5
1
4
6
2–  
4.2x5  
(.17x.20)  
MTG HOLE  
6 (.24) deep  
9
8
7
11M3  
SCREW  
11 10  
22 (.87)  
29.5 (1.16)  
21.5 (.87) 10 (.39)  
84 (3.31)  
114 (4.49)  
[4 (.16)]  
• When mounting, no extra space is needed between units.  
W2PP SPECIFICATIONS  
ES-5534 Rev.12 Page 3/4  
http://www.m-system.co.jp/  
MODEL: W2PP  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Isolation  
*
Waveform  
Shaper  
Output  
Driver  
+
1
2
4
5
9
7
8
+
Timer  
INPUT  
OUTPUT 1  
SENSOR EXCITATION  
+
12V Supply  
Output  
Driver  
3
6
+
OUTPUT 2  
POWER  
10  
11  
U(+)  
V(–)  
Base Socket  
*The timer is provided when the low frequency open collector or the dry contact  
AC/DC switch is selected as one of the outputs.  
Note: The section enclosed by broken line is only with 2nd output option.  
Input Connection Examples  
Output Connection Examples  
Mechanical Contact, Open Collector  
or Clamp-on Pulse Sensor CLSP  
Open Collector  
Dry Contact AC/DC Switch  
• AC Powered  
Relay or  
Counter Coil  
+
+
+
+
1
2
4
+
+
7
8
7
Varistor or Spark  
Quenching Circuit  
LOAD  
8
+12V  
PWR  
U
4kΩ  
Voltage Pulse  
• DC Powered  
Relay or  
Counter Coil  
Voltage Pulse  
7
8
+
+
7
8
Spark Quenching Diode  
+
+
+
+
1
2
4
LOAD  
+12V  
PWR  
Specifications are subject to change without notice.  
W2PP SPECIFICATIONS  
ES-5534 Rev.12 Page 4/4  
http://www.m-system.co.jp/  

W2PP-121N-R/CE 相关器件

型号 制造商 描述 价格 文档
W2PP-121N-R/N MSYSTEM Space-saving Dual Output Signal Conditioners Mini-MW Series 获取价格
W2PP-121N-R/Q MSYSTEM Space-saving Dual Output Signal Conditioners Mini-MW Series 获取价格
W2PP-121N-R2 MSYSTEM Space-saving Dual Output Signal Conditioners Mini-MW Series 获取价格
W2PP-121N-R2/CE MSYSTEM Space-saving Dual Output Signal Conditioners Mini-MW Series 获取价格
W2PP-121N-R2/N MSYSTEM Space-saving Dual Output Signal Conditioners Mini-MW Series 获取价格
W2PP-121N-R2/Q MSYSTEM Space-saving Dual Output Signal Conditioners Mini-MW Series 获取价格
W2PP-121R-M2 MSYSTEM Space-saving Dual Output Signal Conditioners Mini-MW Series 获取价格
W2PP-121R-M2/CE MSYSTEM Space-saving Dual Output Signal Conditioners Mini-MW Series 获取价格
W2PP-121R-M2/N MSYSTEM Space-saving Dual Output Signal Conditioners Mini-MW Series 获取价格
W2PP-121R-M2/Q MSYSTEM Space-saving Dual Output Signal Conditioners Mini-MW Series 获取价格

W2PP-121N-R/CE 相关文章

  • HARTING(浩亭)圆形连接器产品选型手册
    2024-10-31
    6
  • HYCON(宏康科技)产品选型手册
    2024-10-31
    6
  • GREEGOO整流二极管和晶闸管产品选型手册
    2024-10-31
    7
  • 西门子豪掷106亿美元,战略收购工程软件巨头Altair
    2024-10-31
    8