W2SP-13B-P/CE [MSYSTEM]

Space-saving Dual Output Signal Conditioners Mini-MW Series;
W2SP-13B-P/CE
型号: W2SP-13B-P/CE
厂家: M-SYSTEM    M-SYSTEM
描述:

Space-saving Dual Output Signal Conditioners Mini-MW Series

文件: 总4页 (文件大小:114K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: W2SP  
Space-saving Dual Output Signal Conditioners  
[2] OUTPUT 1  
Current  
Mini-MW Series  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
LOW FREQUENCY TRANSMITTER  
(50 Hz minimum)  
Functions & Features  
• Converts the output from a pulse-type transducer  
into a standard process signal  
Typical Applications  
• Positive displacement flowmeters, turbine flowmeters and  
vortex flowmeters  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
• Proximity switches  
29.5 (1.16)  
Model  
88.5  
(3.49)  
ZERO  
SPAN  
[3] OUTPUT 2  
Y: None  
124  
(4.88)  
ZERO  
SPAN  
Current  
mm (inch)  
A: 4 – 20 mA DC (Load resistance 350 Ω max.)  
B: 2 – 10 mA DC (Load resistance 700 Ω max.)  
C: 1 – 5 mA DC (Load resistance 1400 Ω max.)  
D: 0 – 20 mA DC (Load resistance 350 Ω max.)  
E: 0 – 16 mA DC(Load resistance 430 Ω max.)  
F: 0 – 10 mA DC (Load resistance 700 Ω max.)  
G: 0 – 1 mA DC (Load resistance 7000 Ω max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
MODEL: W2SP–[1][2][3]-[4][5]  
ORDERING INFORMATION  
• Code number: W2SP-[1][2][3]-[4][5]  
Specify a code from below for each of [1] through [5].  
(e.g. W2SP-1AA-M2/CE/Q)  
Same range availability as Output 1  
• Frequency range (e.g. 0 – 10 kHz)  
• Special output ranges (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
[4] POWER INPUT  
AC Power  
Note: When the user requires a current and a voltage  
output, specify the current to be the Output 1 which allows  
a greater load.  
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,  
47 – 66 Hz)  
(90 – 264 V for UL)  
DC Power  
R: 24 V DC  
[1] INPUT  
1: Dry contact  
2: Voltage pulse  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
R2: 11 – 27 V DC  
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)  
(Select ‘/N’ for ‘Standards & Approvals’ code.)  
P: 110 V DC  
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
(110 V ±10 % for UL)  
W2SP SPECIFICATIONS  
ES-5502 Rev.14 Page 1/4  
http://www.m-system.co.jp/  
MODEL: W2SP  
[5] OPTIONS (multiple selections)  
Standards & Approvals (must be specified)  
/N: Without CE or UL  
OUTPUT SPECIFICATIONS  
DC Current: 0 – 20 mA DC  
Minimum span: 1 mA  
/CE: CE marking  
Offset: Max. 1.5 times span  
/UL: UL approval, CE marking  
Other Options  
Load resistance: Output drive 15 V max. for Output 1;  
7 V max. for Output 2  
blank: none  
DC Voltage: -10 – +12 V DC (up to 10 V for Output 2)  
Minimum span: 5 mV  
/Q: Option other than the above (specify the specification)  
Offset: Max. 1.5 times span  
Load resistance: Output drive 1 mA max.; at ≥ 0.5 V  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
INSTALLATION  
/C02: Polyurethane coating  
Power Consumption  
/C03: Rubber coating (UL not available)  
TERMINAL SCREW MATERIAL  
AC:  
Approx. 5 VA at 100 V  
/S01: Stainless steel (UL not available)  
Approx. 6 VA at 200 V  
Approx. 7 VA at 240 V  
DC: Approx. 3 W  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 200 g (0.44 lb)  
Connection: M3 screw terminals (torque 0.8 N·m)  
Screw terminal: Chromated steel (standard) or stainless  
steel  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output 1 to output 2 to power  
Overrange output: 0 to 120 % at 1 – 5 V  
Zero adjustment: -5 to +5 % (front)  
PERFORMANCE in percentage of span  
Accuracy: ±0.1 % (output 10 – 100 %)  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Response time: (0 – 90%)  
Span adjustment: 95 to 105 % (front)  
Adjustable individually for each output 1 and output 2.  
Input pulse sensing: DC coupled; detecting pulse rise  
Input filter: Provided with input range < 100 Hz  
(time constant approx. 1 msec.)  
Approx. 1.8 sec. with 0 – 50 Hz  
Approx. 0.7 sec. with 0 – 100 Hz  
Approx. 0.5 sec. with 0 – 500 Hz  
Approx. 0.5 sec. with 0 – 10 kHz  
Low-end cutout: 2 to 5 %  
Ripple: 0.2 %p-p max. with input ≥ 10 %  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute (input to output  
1 to output 2 to power to ground)  
INPUT SPECIFICATIONS  
Excitation: 12 V DC @30 mA; shortcircuit protection  
Frequency range: 0 – 50 Hz through 10 kHz  
Dry Contact: Mechanical contact or open collector  
Pulse width time requirement: 20 μsec. min. for ON and OFF  
≥ 5 msec. with input range < 100 Hz  
Sensing: Approx. 12 V DC @3 mA  
ON/OFF level: ≤ 200 Ω / 0.6 V for ON, ≥ 100 kΩ / 2.5 V for  
OFF  
Voltage Pulse: Square or sine waveforms  
Pulse width time requirement: 20 μsec. min. for high and  
low levels  
≥ 5 msec. with input range < 100 Hz  
Hi level: 2 – 50 V  
Lo level: ≤ 1 V  
Input impedance: 10 kΩ min.  
W2SP SPECIFICATIONS  
ES-5502 Rev.14 Page 2/4  
http://www.m-system.co.jp/  
MODEL: W2SP  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Low Voltage Directive  
EN 61010-1  
Installation Category II  
Pollution Degree 2  
Input or output 1 or output 2 to power input:  
Reinforced insulation (300 V)  
Input to output 1 to output 2: Basic insulation (300 V)  
RoHS Directive  
EN 50581  
Approval:  
UL/C-UL nonincendive Class I, Division 2,  
Groups A, B, C, and D  
(ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213)  
UL/C-UL general safety requirements  
(UL 61010-1, CAN/CSA-C22.2 No.61010-1)  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
6 (.23)  
DIN RAIL  
35mm wide  
3
2
5
1
4
6
2–  
4.2x5  
(.17x.20)  
MTG HOLE  
6 (.24) deep  
9
8
7
11M3  
SCREW  
11 10  
22 (.87)  
29.5 (1.16)  
21.5 (.87) 10 (.39)  
84 (3.31)  
114 (4.49)  
[4 (.16)]  
• When mounting, no extra space is needed between units.  
W2SP SPECIFICATIONS  
ES-5502 Rev.14 Page 3/4  
http://www.m-system.co.jp/  
MODEL: W2SP  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Z
S
Isolation  
Waveform  
Shaper  
Output  
Driver  
+ 1  
– 2  
+ 4  
5
7
8
+
One-Shot  
Smoother  
INPUT  
OUTPUT 1  
SENSOR EXC.  
Z
S
12V Supply  
Output  
Driver  
3
6
+
OUTPUT 2  
POWER  
9
10  
11  
U(+)  
V(–)  
Base Socket  
Note: The section enclosed by broken line is only with 2nd output option.  
Input Connection Examples  
Dry Contact  
Voltage Pulse  
+
1
2
4
+
1
2
4
PWR  
+
PWR  
+
+12V  
+12V  
4kΩ  
Specifications are subject to change without notice.  
W2SP SPECIFICATIONS  
ES-5502 Rev.14 Page 4/4  
http://www.m-system.co.jp/  

相关型号:

W2SP-13B-P/N

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2SP-13B-P/Q

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2SP-13B-P/UL

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2SP-13B-R

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2SP-13B-R/CE

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2SP-13B-R/N

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2SP-13B-R/Q

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2SP-13B-R/UL

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2SP-13B-R2

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2SP-13B-R2/CE

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2SP-13B-R2/N

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

W2SP-13B-R2/Q

Space-saving Dual Output Signal Conditioners Mini-MW Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM