W5PA-A27AD-R2
更新时间:2024-10-29 22:37:17
品牌:MSYSTEM
描述:Terminal Block Dual Output Signal Conditioners W5-UNIT
W5PA-A27AD-R2 概述
Terminal Block Dual Output Signal Conditioners W5-UNIT
W5PA-A27AD-R2 数据手册
通过下载W5PA-A27AD-R2数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: W5PA
Voltage
Terminal Block Dual Output Signal Conditioners W5-UNIT
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)
3: 0 – 1 V DC (Load resistance 100 Ω min.)
4: 0 – 10 V DC (Load resistance 1000 Ω min.)
5: 0 – 5 V DC (Load resistance 500 Ω min.)
6: 1 – 5 V DC (Load resistance 500 Ω min.)
4W: -10 – +10 V DC (Load resistance 2000 Ω min.)
5W: -5 – +5 V DC (Load resistance 1000 Ω min.)
0: Specify voltage (See OUTPUT SPECIFICATIONS)
FREQUENCY TRANSMITTER
Functions & Features
• Converts the output from a pulse-type transducer into two
isolated process signals
• Two independent output ranges
• Four-way isolation (input to output 1 to output 2 to power)
• High-density mounting
45 (1.77)
[4] OUTPUT 2
Same range availability as Output 1
Y: None
97
(3.82)
[5] POWER INPUT
AC Power
41 (1.61)
mm (inch)
M: 85 – 264 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
MODEL: W5PA-[1][2][3][4]-[5][6]
(CE not available)
DC Power
ORDERING INFORMATION
• Code number: W5PA-[1][2][3][4]-[5][6]
Specify a code from below for each [1] through [6].
(e.g. W5PA-A144W4W-R/Q)
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
R2: 11 – 27 V DC
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)
(CE not available)
• Frequency range (e.g. 0 – 1 kHz)
• Special output ranges (For codes Z & 0)
• Specify the specification for option code /Q
(e.g. /C01/S01)
P: 110 V DC
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
(CE not available)
[1] INPUT
A1: Open collector
[6] OPTIONS
blank: none
A2: Mechanical contact
C: 5 V pulse (sensitivity 2 V)
D: 12 V/24 V pulse (sensitivity 5 V)
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
[2] EXCITATION
4: 12 V DC / 30 mA
7: 24 V DC / 12 mA
/C02: Polyurethane coating
/C03: Rubber coating
TERMINAL SCREW MATERIAL
/S01: Stainless steel
[3] OUTPUT 1
Current
A: 4 – 20 mA DC (Load resistance 550 Ω max.)
B: 2 – 10 mA DC (Load resistance 1100 Ω max.)
C: 1 – 5 mA DC (Load resistance 2200 Ω max.)
D: 0 – 20 mA DC (Load resistance 550 Ω max.)
E: 0 – 16 mA DC (Load resistance 685 Ω max.)
F: 0 – 10 mA DC (Load resistance 1100 Ω max.)
G: 0 – 1 mA DC (Load resistance 11 kΩ max.)
Z: Specify current (See OUTPUT SPECIFICATIONS)
CAUTION
The W5PA is designed to accept at the maximum of 100
kHz, which may cause errors due to chattering in the input
pulses.
A filter circuitry (time constant: approx. 1 msec.) is
incorporated to eliminate unwanted chattering when the
mechanical contact input is specified. It is effective for most
relay types, however, an external CR filter as indicated
W5PA SPECIFICATIONS
ES-8533 Rev.7 Page 1/3
http://www.m-system.co.jp/
MODEL: W5PA
below, could be added if the user needs improvement. Limit
Detecting L level
the input frequency to 10 Hz at maximum.
5 V pulse: ≤ 1 V
12 V, 24 V pulse: ≤ 4 V
R
C = 10 μF
R = 1 kΩ
FREQ
XMTR
Relay
C
OUTPUT SPECIFICATIONS
■ DC Current: 0 – 20 mA DC
Minimum span: 1 mA
Offset: Max. 1.5 times span
GENERAL SPECIFICATIONS
Construction: Terminal block
Load resistance: Output drive 11 V max.
■ DC Voltage: -10 – +12 V DC
Spans: Min. 5 mV, max. 20 V
Connection
Input: M3.5 screw terminals (torque 0.8 N·m)
Output & power: M3 screw terminals (torque 0.8 N·m)
Screw terminal: Nickel-plated steel (standard) or stainless
steel
Offset: Max. 1.5 times span
Load resistance: Output drive 10 mA max.; 5 mA for
negative voltage output; at ≥ 0.5 V
Housing material: Flame-resistant resin (black)
Isolation: Input to output 1 to output 2 to power
Overrange output: Approx. -10 to +120 % at 1 – 5 V
Zero adjustment: -2 to +2 % (front)
(±1 % with the output suffix codes 4W and 5W selected)
Span adjustment: 98 to 102 % (front)
(99 to 101 % with the output suffix codes 4W and 5W
selected.)
INSTALLATION
Power Consumption
•AC:
Approx. 6 VA at 100 V
Approx. 7 VA at 200 V
Approx. 8 VA at 264 V
•DC: Approx. 3 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 0 to 90 %RH (non-condensing)
Mounting: DIN rail
INPUT SPECIFICATIONS
Sensor excitation:
Weight: 130 g (0.29 lb)
12 V DC; shortcircuit protection (approx. 35 mA at
shortcircuit)
PERFORMANCE in percentage of span
Accuracy: ±0.1 %
24 V DC; shortcircuit protection (approx. 15 mA at
shortcircuit)
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Response time: Max. 0.5 sec. + 1 pulse cycle (0 – 90 %)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength:
■ Open Collector
Frequency range: 0 – 0.01 Hz through 100 kHz
Pulse width time requirement: ≥ 4 µsec. for both ON and
OFF
Sensing voltage/current: 5 V DC @2 mA
Detecting levels: ≤ 350 Ω / 1 V for ON; ≥ 10 kΩ / 3 V for OFF
■ Mechanical Contact
2000 V AC @1 minute (input to output 1 or output 2 to
power to ground)
1000 V AC @1 minute (output 1 to output 2)
Frequency range: 0 – 0.01 Hz through 30 Hz
Pulse width time requirement: ≥ 10 msec. for both ON and
OFF
STANDARDS & APPROVALS
EU conformity:
Sensing voltage/current: 5 V DC @2 mA
Detecting levels: ≤ 350 Ω / 1 V for ON; ≥ 10 kΩ / 3 V for OFF
■ Voltage Pulse
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
Frequency range: 0 – 0.01 Hz through 100 kHz
Pulse width time requirement: ≥ 4 µsec. for both H and L
levels
EN 50581
Waveform: Square or sine
Input impedance: ≥ 10 kΩ
Max. voltage between input terminals: ±50 V
Detecting H level
5 V pulse: ≥ 3 V
12 V, 24 V pulse: ≥ 6 V
W5PA SPECIFICATIONS
ES-8533 Rev.7 Page 2/3
http://www.m-system.co.jp/
MODEL: W5PA
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
7.4 (.29)
5–M3.5 SCREW
1
2
3
4
5
DIN RAIL
35mm wide
6 (.24)
6
7
8
9 10 11
45 (1.77)
41 (1.61)
[3.3 (.13)]
6–M3 SCREW
• When mounting, no extra space is needed between units.
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Z
S
Isolation
Waveform
Shaper
Digital
Computation
Voltage
Amplifier
Output
Driver
+
–
4
5
3
1
2
+
–
6
7
INPUT
OUTPUT 1
SENSOR EXCITATION
+
Z
S
Excitation
Supply
Output
Driver
8
9
+
OUTPUT 2
POWER
–
10
11
U(+)
V(–)
Note 1: The section enclosed by broken line is only with 2nd output option.
Note 2: DO NOT connect to the terminals 1 and 2.
Input Connection Examples
■ Open Collector or Mechanical Contact ■ Voltage Pulse
+5V
2.5kΩ
+
–
4
5
3
+
–
4
5
3
Vsns
Vsns
Specifications are subject to change without notice.
W5PA SPECIFICATIONS
ES-8533 Rev.7 Page 3/3
http://www.m-system.co.jp/
W5PA-A27AD-R2 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
W5PA-A27AD-R2/Q | MSYSTEM | Terminal Block Dual Output Signal Conditioners W5-UNIT | 获取价格 | |
W5PA-A27AY-M | MSYSTEM | Terminal Block Dual Output Signal Conditioners W5-UNIT | 获取价格 | |
W5PA-A27AY-M/Q | MSYSTEM | Terminal Block Dual Output Signal Conditioners W5-UNIT | 获取价格 | |
W5PA-A27AY-P | MSYSTEM | Terminal Block Dual Output Signal Conditioners W5-UNIT | 获取价格 | |
W5PA-A27AY-P/Q | MSYSTEM | Terminal Block Dual Output Signal Conditioners W5-UNIT | 获取价格 | |
W5PA-A27AY-R | MSYSTEM | Terminal Block Dual Output Signal Conditioners W5-UNIT | 获取价格 | |
W5PA-A27AY-R/Q | MSYSTEM | Terminal Block Dual Output Signal Conditioners W5-UNIT | 获取价格 | |
W5PA-A27AY-R2 | MSYSTEM | Terminal Block Dual Output Signal Conditioners W5-UNIT | 获取价格 | |
W5PA-A27AY-R2/Q | MSYSTEM | Terminal Block Dual Output Signal Conditioners W5-UNIT | 获取价格 | |
W5PA-A27BA1-M | MSYSTEM | Terminal Block Dual Output Signal Conditioners W5-UNIT | 获取价格 |
W5PA-A27AD-R2 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8