WL40MW1F-R [MSYSTEM]

Wireless I/O WL40F Series;
WL40MW1F-R
型号: WL40MW1F-R
厂家: M-SYSTEM    M-SYSTEM
描述:

Wireless I/O WL40F Series

无线
文件: 总7页 (文件大小:678K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: WL40MW1F  
Wireless I/O WL40F Series  
FUNCTIONS & FEATURES  
This unit  
• Incorporates 900MHz band wireless module.  
• Works as a gateway between wireless and RS-485 using  
Modbus-RTU protocol.  
WIRELESS GATEWAY  
(Modbus-RTU Transparent 900MHz Band Wireless Device  
(child device))  
• Incorporates the module compliant with FCC Part 15, and  
can be used only in the United States.  
60 (2.36)  
RELATED PRODUCTS  
For related products of wireless device, refer to M-System's  
[260  
(10.24)]  
web site.  
• PC configurator software (model: W920FCFG)  
Downloadable at M-System’s web site.  
A dedicated cable is required to connect the unit to the PC.  
Please refer to the internet software download site or the  
users manual for the PC configurator software for applicable  
cable types.  
155 (6.10)  
mm (inch)  
Maintenance software  
Maintenance console: MH920 Console International (model:  
MH920CI) (OKI)  
MODEL: WL40MW1F–[1][2]  
(Maintenance software is downloadable at M-System’s web  
site.)  
ORDERING INFORMATION  
• Code number: WL40MW1F-[1][2]  
Specify a code from below for each [1] and [2].  
(e.g. WL40MW1F-R/E/Q)  
Coaxial cable  
• 7.5 m extension cable for rooftop antenna (model: CX-  
SAC0SAD0Q0750) (OKI)  
Using 7.5 m coaxial cable for extension decreases  
transmission distance.  
• Specify the specification for option code /Q  
(e.g. /C01)  
PACKAGE INCLUDES...  
• Terminating resistor (110 Ω, 0.25 W)  
[1] POWER INPUT  
DC Power  
S: 12 V DC  
(Operational voltage range 12 V ±10 %, ripple 10 %p-p max.)  
R: 24 V DC  
GENERAL SPECIFICATIONS  
Connection  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
Wireless network: SMA coaxial connector  
RS-485: Tension clamp (Front Twinconnection)  
Applicable wire size: 0.2 - 1.5 mm  
Power supply: Tension clamp (Front Twinconnection)  
Applicable wire size: 0.2 - 2.5 mm , stripped length 10 mm  
2
, stripped length 10 mm  
[2] OPTIONS (multiple selections)  
Antenna  
2
/S: Sleeve antenna  
Maintenance: Mini USB type B female connector  
Isolation: Power input to Modbus to FE1 to antenna  
connector  
/E: Rooftop antenna  
Other Options  
blank: none  
Indicator LED: Power  
/Q: Option other than the above (specify the specification)  
MODBUS COMMUNICATION  
Protocol: Modbus-RTU  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
Configuration: Bus type multi-drop  
Standard: Conforms to TIA/EIA-485-A  
/C02: Polyurethane coating  
Communication: Half-duplex, asynchronous, no procedure  
Transmission distance: 500 meters max.  
Transmission media: Shielded twisted-pair cable (CPEV-S  
/C03: Rubber coating  
WL40MW1F SPECIFICATIONS  
ES-9081 Rev.1 Page 1/7  
http://www.m-system.co.jp/  
MODEL: WL40MW1F  
0.9 dia.)  
(power input to Modbus to FE1 to antenna connector)  
Status indicator LED: ERR, RD, SD  
Max. no. of connections at once: 31  
Transmission setting: PC configurator software  
Data: RTU (Binary)  
STANDARDS & APPROVALS  
Module conforming to FCC Part 15 incorporated  
Baud rate: 4800, 9600, 19.2k, 38.4 k (bps)  
Parity: None, even or odd  
Stop bit: 1 or 2  
WIRELESS SPECIFICATIONS  
Communication Standard: IEEE802.15.4g  
Frequency: 900MHz band (902 - 928 MHz)  
Max. Tx power: 20mW  
Bandwidth: 400 kHz  
Modulation: GFSK  
Baud rate: Max. 100 kbps  
Channel: 1 - 43ch  
Security: 128bit AES  
Indicator LEDs: 920Run, 920Link, 920ERR  
Protocol: Modbus-RTU  
Communication module: Router module incorporated (OKI)  
Radio configuration: Configurator software  
Antenna  
• Sleeve antenna (model: MH920-ANT-F (S))  
Indoor  
Non-waterproof  
Non-directional  
Gain: 3.0dBi max.  
• Rooftop antenna (model: MH920-ANT-F (R))  
Outdoor/indoor  
Cable length: 2.5 m  
Waterproof performance; IPx6 (except connector)  
Non-directional  
Gain: 2.0dBi max.  
INSTALLATION  
Current consumption:  
24 V DC: ≤ 70 mA  
12 V DC: ≤130 mA  
Operating temperature: -20 to +60°C (-4 to +140°F)  
Operating humidity: 10 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: DIN rail  
Weight  
Unit: Approx. 260 g (0.57 lb)  
Sleeve antenna (standard): 27 g (0.95 oz)  
Rooftop antenna: 52 g (1.83 oz)  
PERFORMANCE  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @ 1 minute  
WL40MW1F SPECIFICATIONS  
ES-9081 Rev.1 Page 2/7  
http://www.m-system.co.jp/  
MODEL: WL40MW1F  
CONFIGURATOR SOFTWARE SETTING  
With configurator software, settings shown below are available.  
Refer to the users manual of W920FCFG for detailed operation.  
WIRELESS SETTING  
ITEM  
SETTING RANGE  
DEFAULT  
0000  
Preferred PAN ID (group number)  
Radio channel number  
Short address  
0000 – FFFE (hexadecimal, 4 digits)  
1 – 43 (selectable up to 10 channels)  
0000 – FFFD (hexadecimal, 4 digits)  
None  
0000  
Network name  
English one-byte characters within 16 characters  
(one-byte space, “-”, “_”, “.”, “@” are usable.)  
Blank  
Encryption key  
0000...0 – FFFF...F  
(hexadecimal, 32 digits)  
0000...0  
Transmitter power output  
Low-speed moving mode  
0.16mW / 1mW / 20mW  
No / Yes  
20mW  
No  
Device type in a network,  
Number of devices in a network  
Child (xed), 1 to 30 devices /  
Child (xed), 31 to 60 devices /  
Child (xed), 61 to 100 devices /  
Child (xed) + child (moving)  
Child (xed), 1 to 30 devices  
Set network quality  
Standard (recommended) /  
Frequency of route switching and delay (higher) /  
Frequency of route switching and delay (highest)  
Standard (recommended)  
Network join mode  
Fixed route  
V3-compatible mode / Fast join mode  
No / Yes  
V3-compatible mode  
No  
Destination short address  
Temporary detour  
0000 – FFFD (hexadecimal, 4 digits)  
No / Yes  
0000  
Yes  
Packet ltering  
None / Yes (polling type)  
1.0 – 60.0 (sec.)  
Yes (polling type)  
1.0 (sec.)  
3.0 (sec.)  
Three times  
Filter timeout on polling  
920Run timeout  
1.0 – 60.0 (sec.)  
Retry times before route switching  
Once / Twice / Three times  
Note: For version con rmation of communication module, refer to the users manual of W920FCFG.  
MODBUS SETTING  
ITEM  
SETTING RANGE  
38400 / 19200 / 9600 / 4800 bps  
Odd / Even / None  
1 bit / 2 bits  
DEFAULT  
38400 bps  
Odd  
Transfer rate  
Parity bit  
Stop bit  
1 bit  
EXTERNAL VIEW  
FRONT VIEW  
Status Indicator LED  
Antenna Connector  
Power  
SD  
RD  
920Link  
920Run  
920ERR  
ERR  
Status Indicator LED  
Maintenance Connector  
Configuration Jack  
CFG2  
DA  
DB  
DG  
SLD  
CFG1  
FE  
Connector for  
RS-485 Communication  
24V  
0V  
NC  
NC  
FE1  
Connector for Power Input *  
* Power input defers depending on the power input code you select.  
WL40MW1F SPECIFICATIONS  
ES-9081 Rev.1 Page 3/7  
http://www.m-system.co.jp/  
MODEL: WL40MW1F  
COMMUNICATION CABLE CONNECTIONS  
■ WIRING CONNECTION WITH SLAVE DEVICES  
WL40MW1F  
REMOTE UNIT  
REMOTE UNIT  
TERMINATOR  
TERMINATOR  
DA  
DB  
DA  
DB  
DA  
DB  
DG  
SLD  
FE  
DG  
SLD  
FE  
DG  
SLD  
FE  
*
* Connect SLD and FE for reducing noise interference if necessary.  
Note: Be sure to connect the terminating resistor included in the product package to the unit  
at both ends of communication line.  
The terminator must be connected across “DA” and “DB”.  
TERMINAL ASSIGNMENTS  
CONNECTORS FOR POWER INPUT  
Unit side connector: MSTBV2,5/5-GF-5,08AU (Phoenix Contact)  
Cable side connector: TFKC2,5/5-STF-5,08AU (Phoenix Contact)  
• Power input code: R (24 V DC)  
• Power input code: S (12 V DC)  
ID  
24V  
0V  
FUNCTION  
ID  
12V  
0V  
FUNCTION  
Power input 24 V  
Power input 0 V  
Not used  
Power input 12 V  
Power input 0 V  
Not used  
24V  
0V  
12V  
0V  
NC  
NC  
FE1  
NC  
NC  
FE1  
NC  
NC  
FE1  
NC  
NC  
FE1  
Not used  
Not used  
Power input earth  
Power input earth  
CONNECTOR FOR RS-485 COMMUNICATION  
Unit side connector: MC1,5/5-GF-3,5 (Phoenix Contact)  
Cable side connector: TFMC1,5/5-STF-3,5 (Phoenix Contact)  
ID  
DA  
FUNCTION  
DA  
DA  
DB  
DG  
SLD  
FE  
DB  
DG  
SLD  
FE  
DB  
DG  
Shield  
Functional earth  
WL40MW1F SPECIFICATIONS  
ES-9081 Rev.1 Page 4/7  
http://www.m-system.co.jp/  
MODEL: WL40MW1F  
MODBUS FUNCTION CODES & SUPPORTED CODES  
Modbus function codes are shown below.  
DATA AND CONTROL FUNCTION  
CODE NAME  
01  
02  
03  
04  
05  
06  
08  
15  
16  
Read Coil Status  
Digital output from the slave (read/write)  
Read Input Status  
Read Holding Registers  
Read Input Registers  
Force Single Coil  
Status of digital inputs to the slave (read only)  
General purpose register within the slave (read/write)  
Collected data from the !eld by the slave (read only)  
Digital output from the slave (read/write)  
Preset Single Register  
Diagnostics  
General purpose register within the slave (read/write)  
Force Multiple Coils  
Preset Multiple Registers  
Digital output from the slave (read/write)  
General purpose register within the slave (read/write)  
EXCEPTION CODE  
CODE NAME  
01  
02  
03  
04  
05  
06  
07  
Illegal Function  
Function code is not allowable for the slave  
Address is not available within the slave  
Data is not valid for the function  
Illegal Data Address  
Illegal Data Value  
Slave Device Failure  
Acknowledge  
Slave Device Busy  
Negative Acknowledge  
WL40MW1F SPECIFICATIONS  
ES-9081 Rev.1 Page 5/7  
http://www.m-system.co.jp/  
MODEL: WL40MW1F  
EXTERNAL DIMENSIONS unit: mm (inch)  
• With sleeve antenna  
DIN RAIL  
35mm wide  
60 (2.36)  
45 (1.77)  
107 (4.21)  
3 (.12)  
[200 (7.87)]  
• With rooftop antenna  
ø3 (.12)  
ø1.2 (.05)  
8 (.31) Hex.  
DIN RAIL  
35mm wide  
ø27  
approx. 2500 (98.4)  
(1.06)  
107 (4.21)  
20  
(.79)  
3 (.12)  
WL40MW1F SPECIFICATIONS  
ES-9081 Rev.1 Page 6/7  
http://www.m-system.co.jp/  
MODEL: WL40MW1F  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
LED  
Two-way  
Antenna Connector  
DA  
wireless circuit  
Isolation  
DB  
DG  
SLD  
FE  
To Other  
Modbus Devices  
Maintenance Connector USB Connector  
Configuration Jack  
Jack  
Control  
Circuit  
24V*  
Power Input  
0V  
NC  
NC  
FE1  
* Power input defers depending on the power input code you select.  
SYSTEM CONFIGURATION EXAMPLES  
PC side as Modbus/Master communicates with child devices via wireless module using Modbus/TCP and RTU protocol,  
and also communicates with slave devices in multi drop connection (RS-485).  
LAN cable  
(STP cable)  
RS-485  
Slave Device  
Slave Device  
MAX. 31  
Slave Device  
Wireless gateway  
(model: WL40MW1F)  
PC  
Modbus/Master  
Wireless gateway  
(model: WL40EW2F)  
Specifications are subject to change without notice.  
WL40MW1F SPECIFICATIONS  
ES-9081 Rev.1 Page 7/7  
http://www.m-system.co.jp/  

相关型号:

WL40MW1F-R/E

Wireless I/O WL40F Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL40MW1F-R/Q

Wireless I/O WL40F Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL40MW1F-R/S

Wireless I/O WL40F Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL40MW1F-S

Wireless I/O WL40F Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL40MW1F-S/E

Wireless I/O WL40F Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL40MW1F-S/Q

Wireless I/O WL40F Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL40MW1F-S/S

Wireless I/O WL40F Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL40MW1KR

Wireless I/O WL40KR Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL40MW1KR-R

Wireless I/O WL40KR Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL40MW1KR-R/E

Wireless I/O WL40KR Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL40MW1KR-R/Q

Wireless I/O WL40KR Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL40MW1KR-R/S

Wireless I/O WL40KR Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM