WL40W1F-DS2 [MSYSTEM]

Wireless I/O WL40F Series;
WL40W1F-DS2
型号: WL40W1F-DS2
厂家: M-SYSTEM    M-SYSTEM
描述:

Wireless I/O WL40F Series

无线
文件: 总7页 (文件大小:574K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: WL40W1F-DS2  
Wireless I/O WL40F Series  
FUNCTIONS & FEATURES  
This unit  
• Operates as a 900MHz band wireless device.  
• Incorporates the module compliant with FCC Part 15, and  
can be used only in the United States.  
• Connects inputs by wireless communication using Modbus  
-RTU protocol.  
WIRELESS INPUT UNIT  
Modbus-RTU Transparent 900MHz Band Wireless Device  
(Child Device), Built-in I/O, 2-wire Transmitter Inputs 2  
points)  
RELATED PRODUCTS  
60 (2.36)  
For related products of wireless device, refer to M-System's  
web site.  
[260  
(10.24)]  
• PC configurator software (model: W920FCFG)  
Downloadable at M-System’s web site.  
A dedicated cable is required to connect the unit to the PC.  
Please refer to the internet software download site or the  
users manual for the PC configurator software for applicable  
cable types.  
155 (6.10)  
mm (inch)  
Maintenance software  
Maintenance console: MH920 Console International (model:  
MH920CI) (OKI)  
MODEL: WL40W1F-DS2-R[1]  
(Maintenance software is downloadable at M-System’s web  
site.)  
Coaxial cable  
ORDERING INFORMATION  
• Code number: WL40W1F-DS2-R[1]  
Specify a code from below for [1].  
(e.g. WL40W1F-DS2-R/E/Q)  
• 7.5 m extension cable for rooftop antenna (model: CX-  
SAC0SAD0Q0750) (OKI)  
Using 7.5 m coaxial cable for extension decreases  
transmission distance.  
• Specify the specification for option code /Q  
(e.g. /C01)  
GENERAL SPECIFICATIONS  
Connection  
I/O TYPE  
Wireless network: SMA coaxial connector  
Power supply: Tension clamp (Front Twinconnection)  
DS2: 2 2-wire transmitter inputs  
Applicable wire size: 0.2 - 2.5 mm  
Input: Separable tension clamp terminal  
Applicable wire size: 0.2 - 1.5 mm , stripped length 10 mm  
2
, stripped length 10 mm  
POWER INPUT  
DC Power  
2
R: 24 V DC  
Maintenance: Mini USB type B female connector  
Isolation: Power input to FE1 to Input 1 to Input 2 to antenna  
connector  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
Indicator LED: Power  
[1] OPTIONS (multiple selections)  
Antenna  
/S: Sleeve antenna  
WIRELESS SPECIFICATIONS  
Communication Standard: IEEE 802.15.4g  
Frequency: 900MHz band (902 - 928 MHz)  
Max. Transmission power: 20mW  
Bandwidth: 400 kHz  
/E: Rooftop antenna  
Other Options  
blank: none  
/Q: Option other than the above (specify the specification)  
Modulation: GFSK  
Baud rate: Max. 100 kbps  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
Channels: 1 to 43ch  
Security: 128bit AES  
Indicator LEDs: 920Run, 920Link, 920ERR  
Protocol: Modbus-RTU  
/C02: Polyurethane coating  
/C03: Rubber coating  
WL40W1F SPECIFICATIONS  
ES-9084 Rev.0 Page 1/7  
http://www.m-system.co.jp/  
MODEL: WL40W1F-DS2  
Communication module: Coordinator module incorporated  
(Oki Electric Industry Co., Ltd. )  
Radio parameters setting: Configurator software  
Antenna  
connector)  
STANDARDS & APPROVALS  
Module conforming to FCC Part 15 incorporated  
•Sleeve antenna (Model: MH920-ANT-F (S))  
Indoor use  
Non-waterproof  
Non-directional  
Gain: 3.0dBi max.  
•Rooftop antenna (Model: MH920-ANT-F (R))  
Outdoor/indoor use  
Cable length: 2.5 m  
Waterproof performance: IPx6 (except connector)  
Non-directional  
Gain: 2.0dBi max.  
SUPPLY OUTPUT  
(across the terminals 1 – 2)  
Output voltage: 24 – 28 V DC with no load  
19 V DC min. at 20 mA  
Current rating: ≤ 22 mA DC  
∙Shortcircuit Protection  
Current limited: Approx. 30 mA  
Protected time duration: No limit  
INPUT SPECIFICATIONS  
Input setting: Configurator software  
No. of input channel: 2  
Input resistance: 250 Ω resistor incorporated  
DC Current: 4 – 20 mA DC  
Conversion rate: 40 msec.  
INSTALLATION  
Current consumption: ≤ 140 mA  
Operating temperature: -10 to +55°C (14 to 131°F)  
Storage temperature: -10 to +55°C (14 to +131°F)  
Operating humidity: 10 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: DIN rail  
Weight  
Unit: Approx. 270 g (0.60 lb)  
Sleeve antenna (standard): 27 g (0.95 oz)  
Rooftop antenna: 52 g (1.83 oz)  
PERFORMANCE  
Conversion accuracy: ±0.05 %  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @ 1 minute  
(power input to FE1 to input 1 to input 2 to antenna  
WL40W1F SPECIFICATIONS  
ES-9084 Rev.0 Page 2/7  
http://www.m-system.co.jp/  
MODEL: WL40W1F-DS2  
CONFIGURATOR SOFTWARE SETTING  
With configurator software, settings shown below are available.  
Refer to the users manual of W920FCFG for detailed operation.  
WIRELESS SETTING  
ITEM  
Preferred PAN ID (group number)  
Radio channel number  
Short address  
SETTING RANGE  
DEFAULT  
0000 – FFFE (hexadecimal, 4 digits)  
1 – 43 (selectable up to 10 channels)  
0000 – FFFD (hexadecimal, 4 digits)  
0000  
None  
0000  
Blank  
Network name  
English one-byte characters within 16 characters  
(one-byte space, “-, “_, ., @” are usable.)  
Encryption key  
0000...0 – FFFF...F  
(hexadecimal, 32 digits)  
0000...0  
Transmitter power output  
Low-speed moving mode  
0.16mW / 1mW / 20mW  
No / Yes  
20mW  
No  
Device type in a network,  
Number of devices in a network  
Child (xed), 1 to 30 devices /  
Child (xed), 31 to 60 devices /  
Child (xed), 61 to 100 devices /  
Child (xed) + child (moving)  
Child (xed), 1 to 30  
devices  
Set network quality  
Standard (recommended) /  
Frequency of route switching and delay (higher) /  
Frequency of route switching and delay (highest)  
Standard (recommended)  
Network join mode  
Fixed route  
V3-compatible mode / Fast join mode  
No / Yes  
V3-compatible mode  
No  
Destination short address  
Temporary detour  
0000 – FFFD (hexadecimal, 4 digits)  
No / Yes  
0000  
Yes  
Packet ltering  
None / Yes (polling type)  
1.0 – 60.0 (sec.)  
Yes (polling type)  
1.0 (sec.)  
3.0 (sec.)  
1
Filter timeout on polling  
920Run timeout  
1.0 – 60.0 (sec.)  
Modbus node address  
Retry times before route switching  
1 – 247  
Once / Twice / Three times  
Three times  
* For version confi rmation of communication module, refer to the users manual of W920FCFG.  
INPUT SETTING  
CHANNEL  
ITEM  
Input enabled / disabled  
Zero input value  
SETTING RANGE  
Enabled / Disabled  
DEFAULT  
Analog input 1  
Enabled  
4.000 – 20.000  
4.000 (mA)  
Full input value  
4.000 – 20.000  
(full input value > zero input value)  
20.000 (mA)  
Fine zero adjustment  
Fine gain adjustment  
Zero scaling value  
-5.00 – +5.00 (%)  
0.9500 – 1.0500  
-32000 – +32000  
-32000 – +32000  
0.0 – 60.0 (sec.)  
Enabled / Disabled  
4.000 – 20.000  
0.00 (%)  
1.0000  
0
Full scaling value  
10000  
First-order !lter time constant  
Input enabled / disabled  
Zero input value  
0.0 (sec.)  
Enabled  
4.000 (mA)  
20.000 (mA)  
Analog input 2  
Full input value  
4.000 – 20.000  
(full input value > zero input value)  
Fine zero adjustment  
Fine gain adjustment  
Zero scaling value  
-5.00 – +5.00 (%)  
0.9500 – 1.0500  
-32000 – +32000  
-32000 – +32000  
0.0 – 60.0 (sec.)  
0.00 (%)  
1.0000  
0
Full scaling value  
10000  
0.0 (sec.)  
First-order !lter time constant  
WL40W1F SPECIFICATIONS  
ES-9084 Rev.0 Page 3/7  
http://www.m-system.co.jp/  
MODEL: WL40W1F-DS2  
EXTERNAL VIEW  
FRONT VIEW  
Antenna Connector  
Status Indicator LED  
Power  
920Link  
920Run  
920ERR  
Maintenance Connector  
Configuration Jack  
CFG2  
24V1  
AI1A  
AI1B  
0V1  
CFG1  
NC  
Input Connector 1  
Input Connector 2  
24V  
0V  
24V2  
AI2A  
AI2B  
0V2  
NC  
NC  
FE1  
NC  
Connector for Power Input  
TERMINAL ASSIGNMENTS  
CONNECTOR FOR POWER INPUT  
Unit side connector: MSTBV2,5/5-GF-5,08AU (Phoenix Contact)  
Cable side connector: TFKC2,5/5-STF-5,08AU (Phoenix Contact)  
ID  
FUNCTION  
24 V Power input 24 V  
24V  
0V  
0 V  
NC  
Power input 0 V  
Not used  
NC  
NC  
FE1  
NC  
Not used  
FE1  
Power input earth  
INPUT CONNECTOR 1  
Unit side connect: MC1,5/5-GF-3,5 (Phoenix Contact)  
Cable side connector: FMC1,5/5-STF-3,5 (Phoenix Contact)  
ID  
FUNCTION  
24V1 2-wire transmitter 1 +  
AI1A 2-wire transmitter 1 –  
AI1B Current input 1 +  
24V1  
AI1A  
AI1B  
0V1  
NC  
0V1  
NC  
Current input 1 –  
Not used  
INPUT CONNECTOR 2  
Unit side connect: MC1,5/5-GF-3,5 (Phoenix Contact)  
Cable side connector: FMC1,5/5-STF-3,5 (Phoenix Contact)  
ID  
FUNCTION  
24V2 2-wire transmitter 2 +  
AI2A 2-wire transmitter 2 –  
AI2B Current input 2 +  
24V2  
AI2A  
AI2B  
0V2  
NC  
0V2  
NC  
Current input 2 –  
Not used  
WL40W1F SPECIFICATIONS  
ES-9084 Rev.0 Page 4/7  
http://www.m-system.co.jp/  
MODEL: WL40W1F-DS2  
MODBUS FUNCTION CODES & SUPPORTED CODES  
Modbus function codes are shown below.  
DATA AND CONTROL FUNCTION  
CODE NAME  
01  
02  
03  
04  
05  
06  
15  
16  
Read Coil Status  
Digital output from the slave (read / write)  
Status of digital inputs to the slave read only  
Read Input Status  
(
)
Read Holding Registers  
Read Input Registers  
Force Single Coil  
General purpose register within the slave read / write  
(
)
Collected data from the !eld by the slave read only  
(
)
Digital output from the slave read / write  
(
)
Preset Single Registers  
Force Multiple Coils  
Preset Multiple Registers  
General purpose register within the slave read / write  
(
)
Digital output from the slave read / write  
(
)
General purpose register within the slave read / write  
(
)
EXCEPTION CODE  
CODE NAME  
01  
02  
03  
04  
05  
06  
07  
Illegal Function  
Function code is not allowable for the slave  
Address is not available within the slave  
Data is not valid for the function  
Illegal Data Address  
Illegal Data Value  
Slave Device Failure  
Acknowledge  
Slave Device Busy  
Negative Acknowledge  
MODBUS I/O ASSIGNMENT  
ADDRESS  
DATA TYPE  
DATA  
Coil (0X)  
1 – 16  
1 – 8  
9
Reserved (unused)  
Reserved (unused)  
Input (1X)  
Analog input error (input range error of analog input 1)  
Analog input error (input range error of analog input 2)  
Reserved (unused)  
10  
11 – 16  
1
Input Register (3X)  
I
I
Analog Input (analog input 1)  
Analog Input (analog input 2)  
Reserved (unused)  
2
3 – 16  
1 – 16  
Holding Register (4X)  
Reserved (unused)  
Note: DO NOT access addresses other than mentioned above. Such access may cause problems such as inadequate operation.  
DATA TYPE  
I: Integer -32768 – +32767  
STATUS  
1 bit: indicates input status.  
Input range error (Input range is out of the range -5 to +105% for scaling setting, or out of the range -32768 to +32767.)  
0: Normal  
1: Error  
INPUT DATA DESCRIPTIONS  
■ANALOG DATA (16 BITS)  
15  
0
When the scaling setting is initial value, the data is 0 to 10000 for input 0 to 100% setting.  
If the input range is -5 to +105% (-500 to +10500) and that is out of range, the data is fixed to -500 or 10500.  
Minus value is converted into negative values, represented in 2’s complements.  
WL40W1F SPECIFICATIONS  
ES-9084 Rev.0 Page 5/7  
http://www.m-system.co.jp/  
MODEL: WL40W1F-DS2  
■DATA ERROR STATUS (1 BIT)  
Data error status is indicated by 1 bit.  
0: OFF  
1: ON  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
WITH SLEEVE ANTENNA  
DIN RAIL  
35mm wide  
60 (2.36)  
45 (1.77)  
107 (4.21)  
3 (.12)  
[200 (7.87)]  
WITH ROOFTOP ANTENNA  
3 (0.12) dia.  
1.2 (.05) dia.  
8 (.31) Hex.  
DIN RAIL  
35mm wide  
27 dia.  
(1.06)  
approx. 2500 (98.4)  
20  
(.79)  
107 (4.21)  
3(.12)  
WL40W1F SPECIFICATIONS  
ES-9084 Rev.0 Page 6/7  
http://www.m-system.co.jp/  
MODEL: WL40W1F-DS2  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
LED  
Two-way  
Antenna Connector  
Wireless Circuit  
24V  
Power Input  
0V  
NC  
NC  
FE1  
USB Connector  
Jack  
Maintenance Connector  
Configuration Jack  
INPUT 1  
Excitation  
Supply  
24V1  
2-WIRE TRANSMITTER  
AI1A  
AI1B  
0V1  
NC  
Input Circuit  
Control  
Circuit  
INPUT (CURRENT INPUT)  
250Ω  
INPUT 2  
Excitation  
Supply  
24V2  
AI2A  
AI2B  
0V2  
2-WIRE TRANSMITTER  
Input Circuit  
INPUT (CURRENT INPUT)  
250Ω  
NC  
HANDLING OF THE UNUSED INPUT  
Connect 5 kΩ (0.5 W) terminating resistor to the input terminal which is not used, as shown below.  
24Vn  
5 kΩ (0.5 )  
AInA  
If the above step is not performed, input becomes -5% or less, and PLC and such show data error.  
However, using PC configuration software (model: W920FCFG) enables the setting of the unused  
input without the above step.  
Specifications are subject to change without notice.  
WL40W1F SPECIFICATIONS  
ES-9084 Rev.0 Page 7/7  
http://www.m-system.co.jp/  

相关型号:

WL40W1F-DS2-R

Wireless I/O WL40F Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL40W1F-DS2-R/E

Wireless I/O WL40F Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL40W1F-DS2-R/Q

Wireless I/O WL40F Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL40W1F-DS2-R/S

Wireless I/O WL40F Series

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MSYSTEM

WL4532V

SMD POWER INDUCTOR-RoHS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FENGJUI

WL4532V-100

SMD POWER INDUCTOR-RoHS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FENGJUI

WL4532V-101

SMD POWER INDUCTOR-RoHS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FENGJUI

WL4532V-102

SMD POWER INDUCTOR-RoHS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FENGJUI

WL4532V-120

SMD POWER INDUCTOR-RoHS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FENGJUI

WL4532V-121

SMD POWER INDUCTOR-RoHS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FENGJUI

WL4532V-150

SMD POWER INDUCTOR-RoHS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FENGJUI

WL4532V-151

SMD POWER INDUCTOR-RoHS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
FENGJUI