DP55D6S [MTU]

DIESEL GENERATOR SET;
DP55D6S
型号: DP55D6S
厂家: MTU ONSITE ENERGY CORPORATION    MTU ONSITE ENERGY CORPORATION
描述:

DIESEL GENERATOR SET

文件: 总4页 (文件大小:205K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DIESEL GENERATOR SET  
DP55D6S  
/
/
55 kWe 60 Hz Prime  
208 - 600V  
(Reference DS60D6S for Standby Rating Technical Data)  
SYSTEM RATINGS  
Prime  
DP55D6SGA  
DP55D6SDA  
DP55D6SPA  
DP55D6SJA  
DP55D6SVA  
DP55D6SRA  
DP55D6SNA  
Voltage (L-L) 240V**  
240V**  
1
208V**  
3
240V**  
3
380V**  
3
480V**  
3
600V**  
3
Phase  
1
PF  
Hz  
kW  
kVA  
1.0  
60  
56  
56  
233  
1.0  
60  
55  
55  
0.8  
60  
58  
72.5  
201  
0.8  
60  
58  
72.5  
174  
0.8  
60  
55  
68.75  
104  
0.8  
60  
55  
68.75  
82  
0.8  
60  
55  
68.75  
66  
Amps  
229  
skVA@30%  
Voltage Dip  
Generator  
Model*  
Temp Rise  
Connection  
119  
132  
200  
200  
265  
172  
138  
362CSL1604  
105 °C/40 °C 105 °C/40 °C  
361CSL1613  
361CSL1602  
105 °C/40 °C  
361CSL1602  
105 °C/40 °C  
12 LEAD  
HI DELTA  
361CSL1602  
105 °C/40 °C  
12 LEAD  
HI WYE  
361CSL1601  
361PSL1633  
105 °C/40 °C 105 °C/40 °C  
12 LEAD  
12 LEAD  
12 LEAD  
DOUBLE DELTA 4 LEAD  
LOW WYE  
HI WYE  
4 LEAD WYE  
** UL 2200 Oered  
CERTIFICATIONS AND STANDARDS  
//  
//ꢀ  
Emissions – EPA Tier 3 Certied  
Performance Assurance Certification (PAC)  
- Generator Set Tested to ISO 8528-5 for Transient Response  
- Veried product design, quality and performance integrity  
- All engine systems are prototype and factory tested  
//ꢀ  
Generator set is designed and manufactured in  
facilities certied to standards ISO 9001:2008 and  
ISO 14001:2004  
//ꢀ  
Power Rating  
- Accepts Rated Load in One Step Per NFPA 110  
//ꢀ  
UL 2200 / CSA – Optional  
– UL 2200 Listed  
– CSA Certied  
/ // /  
2
DP55D6S  
STANDARD FEATURES*  
//ꢀ  
//ꢀ  
MTU Onsite Energy is a single source supplier  
Global Product Support  
2 Year Standard Warranty  
4045HF280 Diesel Engine  
- 4.5 Liter Displacement  
- Mechanical Injection Pump  
- 4-Cycle  
Engine-generator resilient mounted  
Complete Range of Accessories  
Generator  
- Brushless, Rotating Field Generator  
- 2/3 Pitch Windings  
- 300% Short Circuit Capability with Optional PMG  
Digital Control Panel(s)  
- UL Recognized, CSA Certied, NFPA 110  
- Complete System Metering  
- LCD Display  
//ꢀ  
//ꢀ  
//ꢀ  
//ꢀ  
//ꢀ  
//ꢀ  
//ꢀ  
Cooling System  
- Integral Set-Mounted  
- Engine Driven Fan  
STANDARD EQUIPMENT*  
//ꢀ  
Engine  
Air Cleaner  
Oil Pump  
105 °C Maximum Prime Temperature Rise  
1 Bearing, Sealed  
Oil Drain Extension & S/O Valve  
Full Flow Oil Filter  
Fuel Filter with Water Separator  
Jacket Water Pump  
Flexible Coupling  
Full Amortisseur Windings  
125% Rotor Balancing  
3-Phase Voltage Sensing  
Thermostat  
100% of Rated Load - One Step  
5% Maximum Total Harmonic Distortion  
Blower Fan & Fan Drive  
Radiator - Unit Mounted  
Electric Starting Motor - 12V  
Governor – Mechanical Droop  
Base - Formed Steel  
//ꢀ  
Digital Control Panel(s)  
SAE Flywheel & Bell Housing  
Charging Alternator - 12V  
Battery Box & Cables  
Flexible Fuel Connectors  
Flexible Exhaust Connection  
EPA Certied Engine  
Digital Metering  
Engine Parameters  
Generator Protection Functions  
Engine Protection  
Windows®-Based Software  
Multilingual Capability  
Remote Communications to RDP-110 Remote Annunciator  
Programmable Contact Inputs  
Programmable Contact Outputs  
UL Recognized, CSA Certied, CE Approved  
Event Recording  
//ꢀ  
Generator  
NEMA MG1, IEEE and ANSI standards compliance for temperature rise  
and motor starting  
Self-Ventilated and Drip-Proof  
IP 54 Front Panel Rating with Integrated Gasket  
NFPA110 Compatible  
Superior Voltage Waveform  
Solid State, Volts-per-Hertz Regulator  
±1% Voltage Regulation No Load to Full Load  
Brushless Alternator with Brushless Pilot Exciter  
4 Pole, Rotating Field  
* Represents standard product only. Consult Factory/MTU Onsite Energy Distributor for additional congurations.  
/ // /  
3
DP55D6S  
APPLICATION DATA  
//ꢀ  
//ꢀ  
Engine  
Fuel Consumption  
Manufacturer  
Model  
Type  
Arrangement  
Displacement: L (in3)  
Bore: cm (in)  
Stroke: cm (in)  
Compression Ratio  
Rated RPM  
John Deere  
4045HF280  
4-Cycle  
PRIME  
17.8 (4.7)  
13.6 (3.6)  
9.5 (2.5)  
At 100% of Power Rating: L/hr (gal/hr)  
At 75% of Power Rating: L/hr (gal/hr)  
At 50% of Power Rating: L/hr (gal/hr)  
4-Inline  
4.5 (275)  
10.6 (4.19)  
12.7 (5.0)  
19.0:1  
//ꢀ  
Cooling - Radiator System  
1,800  
PRIME  
Engine Governor  
Maximum Power: kWm (bhp)  
Speed Regulation  
Air Cleaner  
Mechanical Droop  
67 (90)  
Ambient Capacity of Radiator: °C (°F)  
Maximum Allowable Static  
50 (122)  
±0.50%  
Pressure on Rad. Exhaust: kPa (in. H20)  
Water Pump Capacity: L/min (gpm)  
Heat Rejection to Coolant: kW (BTUM)  
Heat Rejection to Air to Air: kW (BTUM)  
Heat Radiated to Ambient: kW (BTUM)  
Fan Power: kW (hp)  
0.12 (0.5)  
144 (38)  
33 (1,849)  
4 (233)  
9.2 (522)  
1.16 (1.55)  
Dry  
//ꢀ  
Liquid Capacity (Lubrication)  
Total Oil System: L (gal)  
Engine Jacket Water Capacity: L (gal)  
System Coolant Capacity: L (gal)  
13 (3.4)  
8.5 (2.3)  
16.7 (4.4)  
//ꢀ  
Air Requirements  
PRIME  
5.3 (187)  
//ꢀ  
Electrical  
Aspirating: *m3/min (SCFM)  
Air Flow Required for Rad.  
Electric Volts DC  
Cold Cranking Amps Under -17.8 °C (0 °F)  
12  
925  
Cooled Unit: *m3/min (SCFM)  
Remote Cooled Applications;  
Air Flow Required for Dissipation  
of Radiated Gen-set Heat for a  
Max of 25 °F Rise: *m3/min (SCFM)  
91 (3,162)  
34 (1,176)  
//ꢀ  
Fuel System  
Fuel Supply Connection Size  
Fuel Return Connection Size  
Maximum Fuel Lift: m (ft)  
Recommended Fuel  
3/8” NPT  
3/8” NPT  
1.8 (6)  
Diesel #2  
113 (29.9)  
* Air density = 1.184 kg/m3 (0.0739 lbm/ft3)  
//ꢀ  
Exhaust System  
Total Fuel Flow: L/hr (gal/hr)  
PRIME  
Gas Temp. (Stack): °C (°F)  
Gas Volume at Stack  
515 (959)  
Temp: m3/min (CFM)  
13.5 (477)  
7.5 (30)  
N/A  
Maximum Allowable  
Back Pressure: kPa (in. H20)  
Minimum Allowable  
Back Pressure: kPa (in. H20)  
/ // /  
4
DP55D6S  
WEIGHTS AND DIMENSIONS  
Drawing above for illustration purposes only, based on standard open power 480 volt generator set. Lengths may vary with other voltages. Do not use for installation design. See website  
for unit specic template drawings.  
System  
Dimensions (LxWxH)  
Weight (dry/less tank)  
Open Power Unit (OPU)  
1,873 x 800 x 1,232 mm (73.75 x 31.50 x 48.50 in)  
964 kg (2,120 lb)  
Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specic generator set.  
SOUND DATA  
Unit Type  
Prime Full Load  
Level 0: Open Power Unit dB(A)  
76.1  
Sound data is provided at 7 m (23 ft). Generator set tested in accordance with ISO 8528-10 and with innite exhaust.  
EMISSIONS DATA  
RATING DEFINITIONS AND CONDITIONS  
//ꢀ  
NOx  
3.2  
HC  
0.17  
CO  
0.7  
PM  
0.22  
Prime power ratings apply to installations where utility power  
is unavailable or unreliable. At varying load, the number of  
generator set operating hours is unlimited. A 10% overload  
capacity is available for one hour in twelve. Ratings are in  
accordance with ISO 8528-1, overload power in accordance  
with ISO 3046-1, BS 5514, AS 2789, and DIN 6271.  
Deration Factor:  
Altitude: Consult your local MTU Onsite Energy Power  
Generation Distributor for altitude derations.  
Temperature: Consult your local MTU Onsite Energy Power  
Generation Distributor for temperature derations.  
All units are in g/hp-hr and are EPA D2 cycle values.  
Emission levels of the engine may vary as a function of ambient  
temperature, barometric pressure, humidity, fuel type and  
quality, installation parameters, measuring instrumentation,  
etc. The data provided are laboratory results from one  
engine representing this rating. The data was obtained  
under controlled environmental conditions with calibrated  
instrumentation traceable to the United States National Bureau  
of Standards and in compliance with US EPA regulations found  
within 40 CFR Part 89. The weighted cycle value from each  
engine is guaranteed to be below the US EPA Standards at the  
US EPA dened conditions.  
//ꢀ  
Materials and specications subject to change without notice.  
C/F = Consult Factory/MTU Onsite Energy Distributor  
MTU Onsite Energy  
A Rolls-Royce Power Systems Brand  
www.mtuonsiteenergy.com  

相关型号:

DP562

Miniature LCD Display DigitalPanel Meters
ETC

DP59CF232

SRAM/EEPROM
ETC

DP59CF232K

SRAM/EEPROM
ETC

DP5Z128X32XHP-12C

x32 Flash EEPROM Module
ETC

DP5Z128X32XHP-12CI

x32 Flash EEPROM Module
ETC

DP5Z128X32XHP-15C

x32 Flash EEPROM Module
ETC

DP5Z128X32XHP-15CI

x32 Flash EEPROM Module
ETC

DP5Z128X32XHP-70C

x32 Flash EEPROM Module
ETC

DP5Z128X32XHP-70CI

x32 Flash EEPROM Module
ETC

DP5Z128X32XHP-90C

x32 Flash EEPROM Module
ETC

DP5Z128X32XHP-90CI

x32 Flash EEPROM Module
ETC

DP5Z128X32XP-12C

x32 Flash EEPROM Module
ETC