DIESEL GENERATOR SET  
DS230D6S  
/
/
230 kWe 60 Hz Standby  
208 - 600V  
(Reference DP210D6S for Prime Rating Technical Data)  
SYSTEM RATINGS  
Standby  
DS230D6SPA  
DS230D6SJA  
DS230D6SVA  
DS230D6SWA  
DS230D6SRA  
DS230D6SNA  
Voltage (L-L)  
Phase  
208V**  
3
240V**  
3
380V  
3
440V  
3
480V**  
3
600V**  
3
PF  
Hz  
0.8  
60  
0.8  
60  
0.8  
60  
0.8  
60  
0.8  
60  
0.8  
60  
kW  
kVA  
Amps  
230  
287  
798  
230  
287  
692  
230  
287  
437  
230  
287  
377  
230  
287  
346  
230  
287  
277  
skVA@30%  
Voltage Dip  
Generator Model  
Temp Rise  
Connection  
608  
608  
430  
580  
809  
510  
432CSL6210  
130 °C/40 °C  
12 LEAD LOW WYE  
432CSL6210  
130 °C/40 °C  
12 LEAD HI DELTA  
432CSL6210  
130 °C/40 °C  
12 LEAD HI WYE  
432CSL6210  
130 °C/40 °C  
12 LEAD HI WYE  
432CSL6210  
130 °C/40 °C  
12 LEAD HI WYE  
431PSL6243  
130 °C/40 °C  
4 LEAD WYE  
** UL 2200 Oered  
CERTIFICATIONS AND STANDARDS  
//  
//ꢀ  
Emissions – EPA Tier 3 Certied  
Performance Assurance Certification (PAC)  
- Generator Set Tested to ISO 8528-5 for  
Transient Response  
//ꢀ  
Generator set is designed and manufactured  
in facilities certied to standards ISO 9001:2008 and  
- Veried product design, quality and performance integrity  
ISO 14001:2004  
- All engine systems are prototype and factory tested  
//ꢀ  
//ꢀ  
UL 2200 / CSA – Optional  
Power Rating  
UL 2200 Listed  
CSA Certied  
- Accepts Rated Load in One Step Per NFPA 110  
- Permissible average power output during 24 hours of  
operation is approved up to 85%.  
/ // /  
2
DS230D6S  
STANDARD FEATURES*  
//ꢀ  
//ꢀ  
MTU Onsite Energy is a single source supplier  
Global Product Support  
2 Year Standard Warranty  
6R 1600 Diesel Engine  
- 10.5 Liter Displacement  
- Common Rail Fuel Injection  
- 4-Cycle  
Engine-generator resilient mounted  
Complete Range of Accessories  
Generator  
- Brushless, Rotating Field Generator  
- 2/3 Pitch Windings  
- 300% Short Circuit Capability with Optional PMG  
Digital Control Panel(s)  
- UL Recognized, CSA Certied, NFPA 110  
- Complete System Metering  
- LCD Display  
//ꢀ  
//ꢀ  
//ꢀ  
//ꢀ  
//ꢀ  
//ꢀ  
//ꢀ  
Cooling System  
- Integral Set-Mounted  
- Engine Driven Fan  
STANDARD EQUIPMENT*  
//ꢀ  
Engine  
Air Cleaner  
Oil Pump  
Brushless Alternator with Brushless Pilot Exciter  
4 Pole, Rotating Field  
Oil Drain Extension & S/O Valve  
Full Flow Oil Filters  
130 °C Maximum Standby Temperature Rise  
1 Bearing, Sealed  
Closed Crankcase Ventilation  
Jacket Water Pump  
Thermostats  
Flexible Coupling  
Full Amortisseur Windings  
125% Rotor Balancing  
Blower Fan & Fan Drive  
Radiator - Unit Mounted  
Electric Starting Motor - 24V  
Governor – Electronic Isochronous  
Base - Formed Steel  
3-Phase Voltage Sensing  
±1% Voltage Regulation  
100% of Rated Load - One Step  
5% Maximum Total Harmonic Distortion  
SAE Flywheel & Bell Housing  
Charging Alternator - 24V  
Battery Box & Cables  
Flexible Fuel Connectors  
Flexible Exhaust Connection  
EPA Certied Engine  
//ꢀ  
Digital Control Panel(s)  
Digital Metering  
Engine Parameters  
Generator Protection Functions  
Engine Protection  
CAN Bus ECU Communications  
Windows®-Based Software  
Multilingual Capability  
//ꢀ  
Generator  
NEMA MG1, IEEE and ANSI standards compliance for temperature rise  
and motor starting  
Sustained short circuit current of up to 300% of the rated current for  
up to 10 seconds  
Remote Communications to RDP-110 Remote Annunciator  
16 Programmable Contact Inputs  
Up to 11 Contact Outputs  
UL Recognized, CSA Certied, CE Approved  
Event Recording  
Self-Ventilated and Drip-Proof  
Superior Voltage Waveform  
Digital, Solid State, Volts-per-Hertz Regulator  
No Load to Full Load Regulation  
IP 54 Front Panel Rating with Integrated Gasket  
NFPA110 Compatible  
* Represents standard product only. Consult Factory/MTU Onsite Energy Distributor for additional congurations.  
/ // /  
3
DS230D6S  
APPLICATION DATA  
//ꢀ  
//ꢀ  
Engine  
Fuel Consumption  
Manufacturer  
Model  
Type  
Arrangement  
Displacement: L (Cu In)  
Bore: cm (in)  
Stroke: cm (in)  
Compression Ratio  
Rated RPM  
Engine Governor  
Max Power: kWm (bhp)  
Speed Regulation  
Air Cleaner  
MTU  
STANDBY  
66 (17.5)  
54 (14.2)  
39 (10.2)  
6R 1600 G70S  
4-Cycle  
6-Inline  
10.5 (641)  
12.2 (4.8)  
15 (5.91)  
17.5:1  
At 100% of Power Rating: L/hr (gal/hr)  
At 75% of Power Rating: L/hr (gal/hr)  
At 50% of Power Rating: L/hr (gal/hr)  
//ꢀ  
Cooling - Radiator System  
1,800  
ECU 8  
312 (418)  
±0.25%  
Dry  
STANDBY  
50 (122)  
Ambient Capacity of Radiator: °C (°F)  
Max. Restriction of Cooling Air, Intake,  
and Discharge Side of Rad.: kPa (in. H20)  
Water Pump Capacity: L/min (gpm)  
Heat Rejection to Coolant: kW (BTUM)  
Heat Rejection to After Cooler: kW (BTUM)  
Heat Radiated to Ambient: kW (BTUM)  
Fan Power: kW (hp)  
0.2 (0.8)  
277 (73.1)  
143 (8,132)  
84 (4,777)  
27.5 (1,564)  
14.9 (20)  
//ꢀ  
Liquid Capacity (Lubrication)  
Total Oil System: L (gal)  
Engine Jacket Water Capacity: L (gal)  
System Coolant Capacity: L (gal)  
46 (12.2)  
45 (11.9)  
82 (21.7)  
//ꢀ  
Air Requirements  
STANDBY  
30 (1,059)  
//ꢀ  
Electrical  
Aspirating: *m3/min (SCFM)  
Air Flow Required for Rad.  
Electric Volts DC  
Cold Cranking Amps Under -17.8 °C (0 °F)  
24  
950  
Cooled Unit: *m3/min (SCFM)  
Remote Cooled Applications;  
Air Flow Required for Dissipation  
of Radiated Gen-set Heat for a  
Max of 25 °F Rise: *m3/min (SCFM)  
396 (13,985)  
99.9 (3,527)  
//ꢀ  
Fuel System  
Fuel Supply Connection Size  
Fuel Return Connection Size  
#10 JIC 37° Female * Air density = 1.184 kg/m3 (0.0739 lbm/ft3)  
M20 x 1.5 Male Adapter Provided  
#6 JIC 37° Female  
//ꢀ  
Exhaust System  
M14 x 1.5 Male Adapter Provided  
Maximum Fuel Lift: m (ft)  
Recommended Fuel  
Total Fuel Flow: L/hr (gal/hr)  
5 (16)  
Diesel #2  
198 (60.4)  
STANDBY  
430 (806)  
Gas Temp. (Stack): °C (°F)  
Gas Volume at Stack  
Temp: m3/min (CFM)  
Maximum Allowable  
72 (2,542)  
15 (60.2)  
Back Pressure: kPa (in. H20)  
/ // /  
4
DS230D6S  
WEIGHTS AND DIMENSIONS  
Drawing above for illustration purposes only, based on standard open power 480 volt generator set. Lengths may vary with other voltages. Do not use for installation design. See website  
for unit specic template drawings.  
System  
Dimensions (LxWxH)  
Weight (dry/less tank)  
Open Power Unit (OPU)  
3,658 x 1,883 x 1,855 mm (144 x 74.13 x 73 in)  
3,078 kg (6,785 lb)  
Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specic generator set.  
SOUND DATA  
Unit Type  
Standby Full Load  
Level 0: Open Power Unit dB(A)  
86.3  
Sound data is provided at 7 m (23 ft). Generator set tested in accordance with ISO 8528-10 and with innite exhaust.  
EMISSIONS DATA  
RATING DEFINITIONS AND CONDITIONS  
//ꢀ  
NOx + NMHC  
4.71  
CO  
0.61  
PM  
0.06  
Standby ratings apply to installations served by a reliable  
utility source. The standby rating is applicable to varying  
loads for the duration of a power outage. No overload  
capability for this rating. Ratings are in accordance with  
ISO 8528-1, ISO 3046-1, BS 5514, AS 2789, and DIN 6271.  
Deration Factor:  
Altitude: Consult your local MTU Onsite Energy Power  
Generation Distributor for altitude derations.  
Temperature: Consult your local MTU Onsite Energy Power  
Generation Distributor for temperature derations.  
All units are in g/hp-hr and at 100% load.  
Emission levels of the engine may vary as a function of ambient  
temperature, barometric pressure, humidity, fuel type and  
quality, installation parameters, measuring instrumentation,  
etc. The data provided are laboratory results from one  
engine representing this rating. The data was obtained  
under controlled environmental conditions with calibrated  
instrumentation traceable to the United States National Bureau  
of Standards and in compliance with US EPA regulations found  
within 40 CFR Part 89. The weighted cycle value (not shown)  
from each engine is guaranteed to be below the US EPA  
Standards at the US EPA dened conditions.  
//ꢀ  
Materials and specications subject to change without notice.  
C/F = Consult Factory/MTU Onsite Energy Distributor  
MTU Onsite Energy  
A Rolls-Royce Power Systems Brand  
www.mtuonsiteenergy.com  

相关型号:

DS232

100 Watt DC-DC Converters
POWER-ONE

DS232

Dual RS-232 Transmitter/Receiver
DALLAS

DS2320-7EP

DC-DC Regulated Power Supply Module, 2 Output, 100W, Hybrid, HEAT SINK, METAL, CASE S02, MODULE
BEL

DS2320-7EPB2

DC-DC Regulated Power Supply Module, 2 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL

DS2320-7EPD0T

DC-DC Regulated Power Supply Module, 2 Output, Hybrid, METAL, CASE S02, MODULE
BEL

DS2320-7EPD0TB2

DC-DC Regulated Power Supply Module, 2 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL

DS2320-7EPD1

DC-DC Regulated Power Supply Module, 2 Output, Hybrid, METAL, CASE S02, MODULE
BEL

DS2320-7EPD1T

DC-DC Regulated Power Supply Module, 2 Output, Hybrid, HEAT SINK, METAL, CASE S02, MODULE
BEL

DS2320-7EPD1TB2

DC-DC Regulated Power Supply Module, 2 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL

DS2320-7EPD2B1

DC-DC Regulated Power Supply Module, 2 Output, Hybrid, METAL, CASE S02, MODULE
BEL

DS2320-7EPD2B2

DC-DC Regulated Power Supply Module, 2 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL

DS2320-7EPD2TB2

DC-DC Regulated Power Supply Module, 2 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL