ACA-20PC Series  
Digital, LED-Display AC Ammeters with  
Built-in Current Transformers  
s
DATEL's new ACA-20PC Series are the first digital ac ammeters to incorporate on-board current  
transformers (CT’s), and they are amazingly easy to use. Simply pass the current-carrying load  
wire through the ACA-20PC’s on-board CT, apply power to the meter's two supply terminals,  
and you’re instantly measuring ac currents over one of four ranges (0-2A with 1mA resolu-  
tion, 0-20A with 10mA resolution, or 0-50A and 0-100A with 100mA resolution). Absolutely no  
external components, such as expensive low-value shunts or 5A "donut" CT’s, are required.  
FEATURES  
Built-in Current Transformers for direct measurement  
of 0 to 2/20/50/100 Amps  
Functionally complete:  
On-board current transformers  
Scaling/interface circuitry  
Precision A/D converters  
Bright red LED displays  
Meters are ac powered (120/220Vac @ 50/60Hz) or dc powered (+5-40V) and impose  
minimal loads (50mA max. and 120mA max., respectively) on their supplies. All models employ  
auto-zeroing circuits, precision bandgap references, and super stable thin-film resistors for  
unsurpassed accuracy ( 0.15ꢀFS) and stability.  
8 different models  
Subminiature, 1.38" x 0.88" package  
The functionally complete ACA-20PC ammeters provide all the scaling/interface circuitry to  
mate the CT’s output to a precision (3½ digit) A/D converter. The A/D's output goes directly to  
drivers for the meters’ large (0.37"/9.4mm digit height), easy-to-read, LED displays. AC-pow-  
ered units have on-board AC/DC converters, and wide-range dc-powered units have on-board  
linear regulators. AC-powered models can be powered by the same ac supply whose current  
they are monitoring. The 2A and 20A, 85-264Vac, 50/60Hz ("AC1") models feature additional  
on-board terminal blocks to supply power to the external load. All models provide 2000Vdc iso-  
lation between the measured ac current and their power supply, and all are UL/CSA recognized.  
Easy-to-read, 0.37"/9.4mm digits  
AC powered models 85-264Vac @ 50/60Hz  
"Self-powered" 85-264Vac, 2A and 20A models feature  
built-in load connections  
+5-40V dc powered models  
2000V isolation; UL/CSA recognized  
Each meter is housed in a subminiature, 1.38" x 0.88", epoxy-encapsulated package. Total  
behind-the-panel installation depth is approximately 2 inches.  
SIMPLIFIED SCHEMATIC DIAGRAM  
CAL.  
+
3½ DIGIT  
A/D CONVERTER  
+V  
–V  
LED DISPLAY  
RMS-to-DC  
CONVERTER  
POWER  
CONVERTER  
(L1)  
BUILT-IN  
CURRENT  
TRANSFORMER  
A
B
Figure 1. ACA-20PC Series simplified schematic  
TB1  
MEASURED AC  
LOAD CURRENT  
AC INPUT POWER  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com/support  
MPM_ACA_20PC.B11 Page 1 of 6  
ACA-20PC Series  
Digital, LED-Display AC Ammeters with  
Built-in Current Transformers  
Performance/Functional Specifications  
Typical at TA = +25°C, unless otherwise noted. ➀  
Min.  
Typ.  
Max.  
1.999  
19.99  
50.0  
Units  
Amps  
Amps  
Amps  
Amps  
Amps  
Physical/Environmental  
Full-Scale Current (45-450Hz) ➁  
ACA-20PC-1-XXX-XX  
ACA-20PC-2-XXX-XX ➂  
ACA-20PC-3-XXX-XX  
ACA-20PC-4-XXX-XX  
DMS-30798-C  
Case Material  
Dimensions  
Polycarbonate  
1.38”W x 0.88”H. Depth is model depen-  
dent (see mechanical specification)  
Weight:  
100.0  
30.0  
ACA-20PC-1-XXX-XX  
ACA-20PC-2-XXX-XX  
ACA-20PC-3-XXX-XX  
ACA-20PC-4-XXX-XX  
DMS-30798-C  
1.1 ounces (31 grams)  
1.1 ounces (31 grams)  
1.3 ounces (37 grams)  
1.5 ounces (43 grams)  
1.0 ounces (28 grams)  
1.5 x rated full-scale current  
Overcurrent Rating ➁  
Performance  
Sampling Rate  
2.5 reading per second  
0.15ꢀFS 6 Counts  
Accuracy ➁  
Measurement Type  
Sine wave input, full-wave averaging,  
rms calibrated  
The ACA-20PC-1-AC1-RL and ACA-20PC-2-AC1-RL have 4-position on-board  
terminal blocks. All other models have 2-position terminal blocks.  
Temperature Drift (0 = +60°C)  
Zero Reading (Vin = 0 Volts)  
Dielectric Withstanding Voltage  
Power Supply Voltage ➄  
0.2  
0.4  
Cnts/°C  
Specified full-scale currents are those passing through the built-in CT's  
primary(load) circuit, over the frequency of 45-450Hz. The Overcurrent Rating  
is a continuous rating that applies to the measured ac load current. It does  
not apply to any circuitry external to the meter. Accuracy is guaranteed to the  
rated current.  
“–001” “000”  
“001” Counts  
2000  
Vdc  
ACA-20PC-X-AC1-RL (47-99Hz)  
ACA-20PC-X-DC1-RL  
85  
120  
264  
+40  
Vac  
For the ACA-20PC-2-AC1-RL, if the load is connected to the meter's on-board  
4-position terminal block, the 20A full scale range requires 12AWG solid  
copper wire on all connections. If 14AWG solid copper wire is used, the current  
should be limited to 15A. See Figure 3.  
+4.75  
Vdc  
Power Supply Current ➃  
ACA-20PC-X-AC1-RL (47-99Hz)  
ACA-20PC-X-DC1-RL  
30  
50  
mA  
All specified maximum power supply currents are steady-state values.  
AC-powered models can draw higher surges at initial turn-on.  
+8  
+12  
mAdc  
Maximum reverse polarity protection on "DC1" models is –40Vdc.  
Power Supply Terminal Block  
ACA-20PC-1-AC1-RL and ACA-20PC-2-AC1-RL  
(2A and 20A ac-powered models with 4-position terminal blocks):  
Ordering Information  
Wire Size and Type  
12-20AWG (solid), 14-20AWG (stranded)  
0.25 inches  
ACA - 20PC - 1 - AC1 - RL - L - C  
Insulation Strip Length  
Screw Tightening Torque  
Maximum Rated Current  
RoHS  
(45-450Hz)  
Input Range:  
4.4 lb·in (0.5N·m) 20ꢀ  
Leaded CT (100A model)  
20A with 12AWG solid wire; 15A with  
14AWG solid or stranded wire  
1 = 1.999A  
2 = 19.99A  
3 = 50.0A  
4 = 100.0A  
LED Color:  
RL = Red Standard  
BL = Blue Standard  
PGL = Green Standard  
Maximum Rated Voltage  
ACA-20PC-X-XXX-XX  
630V (VDE 0110-V. Group 2)  
250V (VDE 0110-V Group 3)  
Power Supply:  
AC1 = 85-264Vac@50/60Hz  
DC1 = +5-40Vdc  
(All other ac or dc-powered models with 2-position terminal blocks):  
Wire Size and Type  
Insulation Strip Length  
Screw Tightening Torque  
Display  
16-24AWG (solid or stranded)  
0.25 inches  
DMS-30798-C: 30Amp model with a wire lead CT and “-AC1”  
power supply specifications. See Mechanical section for dimensions.  
2.2 lb·in (0.25 N·m) 20ꢀ  
Accessories: DMS-20-CP Panel cutout punch  
A DMS-BZL4-C bezel assembly with sealing gasket is supplied with each ammeter.  
Display Type and Size  
Overrange Indication  
Decimal Point  
3½ digit, 0.37"/9.4mm high LED  
“1_ _ _”  
Fixed, model dependent  
Physical/Environmental  
Operating Temperature  
Storage Temperature  
Humidity (non-condensing)  
0
–40  
0
+60  
+75  
95  
°C  
°C  
www.murata-ps.com/support  
MPM_ACA_20PC.B11 Page 2 of 6  
ACA-20PC Series  
Digital, LED-Display AC Ammeters with  
Built-in Current Transformers  
TECHNICAL NOTES  
designations. Also, ac-powered ACA-20PC ammeters do not include  
or require a connection to earth/chassis ground. However, in many  
applications, external ac loads which are connected directly to the  
ACA-20PC’s built-in auxiliary terminal blocks must be wired with  
proper polarity and connected to earth/chassis ground.  
IMPORTANT! To ensure safe and reliable operation, ACA-20PC  
ammeters must be installed and serviced by qualified technical  
personnel. Contact DATEL if there is any doubt regarding ammeter  
installation and/or operation.  
5. Connector Torque Ratings: It is important to tighten TB1's screw  
terminals to their rated torque specifications of 4.4 pound-inches  
(0.5Nm) for four-terminal ammeters (ACA-20PC-1-AC1-RL and ACA-  
20PC-2-AC1-RL), and 3.6 pound-inches (0.4Nm) for two-terminal  
ammeters. Proper tightening will minimize connector losses and  
ensure safe, reliable operation.  
1. Measurement Type: ACA-20PC ac ammeters employ a full-wave-  
rectified, average responding, rms-calibrated circuit to measure the  
stepped-down output of their on-board, L1 current transformer (CT) .  
Stated accuracy specifications are measured using a sine-wave cur-  
rent at or close to the specified full scale input level, at nominal line  
frequency.  
6. 100 Amp Model (ACA-20PC-4-XXX): This model’s built-in current  
transformer requires a larger panel cutout width dimension. See  
Mechanical Specifications for more information.  
2. Calibration: Periodic recalibration of ACA-20PC ammeters is not  
required under normal, indoor operating environments. If user  
calibration is necessary, it should be performed by qualified technical  
personnel. Calibration is performed with potentially lethal voltages  
applied to the ACA-20PC and its associated wiring, with the specified  
full-scale current flowing through the ammeter’s built-in current  
transformer.  
7. DC-Powered Models: DC-powered models draw minimal supply  
currents and in most applications can be fused according to the  
supply wire’s maximum amperage rating. However, be sure to check  
and comply with all applicable codes and regulations to ensure  
proper installation and operation.  
A plastic, fully insulated adjusting tool must be used to access the  
recessed calibration potentiometer located on the back of the meter  
(see Mechanical Specifications). Contact DATEL if additional informa-  
tion is required regarding calibration, setup, or any other technical  
issue pertaining to the ACA-20PC.  
8. Isolation: The on-board CT (L1) provides a minimum 2000Vdc  
isolation between the current-carrying conductor passing through its  
primary circuit and the ammeter supply voltage connected to TB1. Of  
course, this isolation rating only applies to applications in which the  
load wiring (i.e., the wire passing through the CT’s center hole) does  
not connect directly or indirectly to TB1-A or TB1-B.  
3. Wire Gauges and Fusing: Wires specified in the Functional Specifi-  
cations section must be used for making connections to ACA-20PC  
Series ammeters. All power-supply and load wiring must be rated for  
the supply voltages and currents they will conduct and must comply  
with any code or application-mandated requirements pertaining to  
the user’s specific installation.  
PANEL INSTALLATION  
All connections to ACA-20PC Series ammeters must be made  
after the ammeter is securely attached to the panel and with all  
load and supply voltages de-energized (off).  
ACA-20PC Series ammeters are not internally fused. Special attention  
must be paid to ACA-20PC-1-AC1 (0-2A range) and ACA-20PC-2-AC1  
(0-20A range) ac-powered models when their built-in auxiliary termi-  
nal block connections on TB1 are used to supply power to an external  
load. The input supply wires connected to both the ammeter and the  
load must be fused according to the current rating of the wire gauge  
being used, in accordance with applicable regulatory codes, but not  
to exceed TB1’s maximum 20A rating. If TB1 is not used to supply  
power to external loads, a 0.25A/250V time delay/time lag fuse must  
used.  
Care should be exercised when passing the load-carrying conduc-  
tor through the meter’s built-in CTparticularly when larger-gauge  
conductors are used. The position of the installed wire should be  
such that minimal forces are applied to the built-in CT, TB1, or to  
the ammeter itself. In high-vibration environments, adequate strain  
reliefs be used for all load and supply wiring.  
To ensure a secure panel-mount installation, DATEL recommends  
using the DMS-BZL4 bezel assembly (with sealing gasket) supplied  
with each ammeter. Also, please note that the ACA-20PC-4-XXX  
100A oversize CT requires a larger panel-cutout width of 1.350"  
(34.3mm). See Mechanical Specifications for detailed cutout and  
ammeter dimensions.  
ACA-20PC-3-AC1 (0-50A range, ac-powered) and ACA-20PC- 4-AC1  
(0-100A, ac-powered) models’ TB1 is to be used only for powering  
the ammeters’ internal circuitry; it must not be used to supply power  
to external loads. The supply wires feeding these models must be  
fused with a 0.25A time delay/time lag fuse, in accordance with  
applicable regulatory codes.  
Following the four-step sequence shown in Figure 2 belowbeing  
careful not to apply excessive force or twisting motionsinsert the  
ammeter into the panel opening. When using the DMS-BZL4 bezel  
assembly, install its sealing gasket so it is positioned between the  
ammeter’s front flange and panel front surface (see Mechanical  
Specifications). Be sure to use and securely tighten all four screws  
supplied with the bezel assembly.  
Wire insulation must be stripped to within 10ꢀ of the stated dimen-  
sions, and wires should be inserted into TB1 such that their insulation  
is not pinched by the screw terminal.  
4. AC Supply Polarity and Grounding: The two ac supply inputs,  
TB1-A and TB1-B, on ac-powered ammeters are not in themselves  
polarity sensitive, that is, they have no internal "AC LO" or "AC HI"  
www.murata-ps.com/support  
MPM_ACA_20PC.B11 Page 3 of 6  
ACA-20PC Series  
Digital, LED-Display AC Ammeters with  
Built-in Current Transformers  
Step 1.  
Step 2.  
Step 3.  
Step 4.  
Panel  
Figure 2. Panel Installation  
TYPICAL WIRING DIAGRAM  
First pass and carefully dress one external load wire through the  
FUSED  
AC POWER  
SUPPLY  
on-board CT (L1). Then connect the ac supply and load wires to TB1  
as shown. If required, verify that correct line-power polarities are  
applied to the external load (see Technical Note 4). Ensure all wires  
are stripped and terminals torqued correctly. For proper operation,  
pass only one load wire through the on-board CT’s center hole.  
ACA-20PC-X-ACX  
TO AC LOAD  
FUSED  
85-264Vac  
POWER  
FUSED  
85-264Vac  
POWER  
ACA-20PC-1-AC1-RL  
AC SUPPLY  
Figure 4. All Other AC-Powered Models  
+
FUSED  
DC POWER  
ACA-20PC-2-AC1-RL  
SUPPLY  
ACA-20PC-X-DCX  
TO LOAD  
85-264Vac TO LOAD  
Figure 3. 2A and 20A, 85-264V AC-Powered Models  
With Auxilliary Load Connections  
+
TO AC LOAD  
AC SUPPLY  
Figure 5. All DC-Powered Models  
www.murata-ps.com/support  
MPM_ACA_20PC.B11 Page 4 of 6  
ACA-20PC Series  
Digital, LED-Display AC Ammeters with  
Built-in Current Transformers  
MECHANICAL SPECIFICATIONS  
ACA-20PC-1 & 2-AC1-RL  
2A and 20A, 85-264V ac-powered models  
ACA-20PC-1 & 2  
2A and 20A, all other models  
Hole Diameter:  
0.27 (6.9) min.  
Hole Diameter:  
0.27 (6.9) min.  
2.01  
2.01  
(51.1)  
(51.1)  
1.00  
(25.4)  
1.00  
(25.4)  
0.040  
(1.02)  
0.040  
(1.02)  
0.80  
(20.3)  
0.80  
(20.3)  
0.040  
(1.02)  
1.30  
(33.0)  
0.040  
(1.02)  
1.30  
(33.0)  
0.040  
(1.02)  
0.040  
(1.02)  
0.88  
(22.4)  
0.88  
(22.4)  
1.38  
(35.1)  
1.38  
(35.1)  
1.32  
1.32  
(33.5)  
(33.5)  
FRONT VIEW  
BACK VIEW  
FRONT VIEW  
BACK VIEW  
CAL.  
CAL.  
ACA-20PC-3 Series  
ACA-20PC-4 Series  
50A models  
100A models with pc-board mounted CTs  
THIS MODEL REQUIRES A PANEL  
CUTOUT WIDTH OF 1.350" (34.3MM)  
*
1.33  
(33.8)  
*
Hole Diameter:  
0.35 (8.9) min.  
Hole Diameter:  
0.55 (14.0) min.  
2.53  
(64.3)  
2.12  
(53.8)  
1.00  
(25.4)  
1.00  
(25.4)  
0.040  
(1.02)  
0.040  
(1.02)  
0.80  
(20.3)  
0.040  
(1.02)  
0.80  
(20.3)  
1.30  
(33.0)  
0.040  
(1.02)  
0.040  
(1.02)  
1.30  
(33.0)  
0.040  
(1.02)  
0.88  
(22.4)  
0.88  
(22.4)  
1.38  
(35.1)  
1.38  
(35.1)  
1.54  
(39.1)  
1.32  
(33.5)  
FRONT VIEW  
BACK VIEW  
FRONT VIEW  
BACK VIEW  
CAL.  
CAL.  
www.murata-ps.com/support  
MPM_ACA_20PC.B11 Page 5 of 6  
ACA-20PC Series  
Digital, LED-Display AC Ammeters with  
Built-in Current Transformers  
BEZEL INSTALLATION AND RECOMMENDED DRILL AND  
PANEL CUTOUT  
MECHANICAL SPECIFICATIONS, CONTINUED  
0.187  
(4.75)  
#2-56 INSERT  
0.156 (3.96) DEEP  
ACA-20PC-4-XXX-L (100A model)  
DMS-30798-C (30A model)  
OD: 100A Model: 1.18 (30.0)  
1.280  
(32.51)  
DMS-30798-C (30A): 0.87 (22.0)  
FRONT VIEW  
ID: 100A Model: 0.58 (14.7)  
DMS-30798-C (30A): 0.35 (8.9)  
1.826 (46.38)  
0.116 (2.95)  
Lead Length:  
2.0 (50.5) min.  
INTERNAL CORNER RADII:  
0.032 (0.81) MAX.  
1.07  
(27.18)  
0.838  
(21.29)  
PANEL CUTOUT  
1.00  
(25.4)  
0.040  
(1.02)  
®
®
0.145 (3.68)  
1.336 (33.93)*  
1.626 (41.30)  
0.093 (2.362) DIA  
(4 REQUIRED)  
0.80  
(20.3)  
0.040  
(1.02)  
1.30  
(33.0)  
0.040  
(1.02)  
* 1.350 (34.3) for ACA-20PC-4-XXX 100A model  
with pc-board mounted CTs.  
0.88  
(22.4)  
1.38  
(35.1)  
1.14  
(29.0)  
FRONT VIEW  
BACK VIEW  
CAL.  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
ISO 9001 and 14001 REGISTERED  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
notice.  
© 2013 Murata Power Solutions, Inc.  
www.murata-ps.com/support  
MPM_ACA_20PC.B11 Page 6 of 6  

相关型号:

ACA-20PC-3-DC1-BL-C

民用设备,工业设备
MURATA

ACA-20PC-3-DC1-PGL-C

民用设备,工业设备
MURATA

ACA-20PC-3-DC1-RL-C

民用设备,工业设备
MURATA

ACA-20PC-4

Digital, LED-Display AC Ammeters with Built-in Current Transformers
MURATA

ACA-20PC-4-AC1-BL-C

民用设备,工业设备
MURATA

ACA-20PC-4-AC1-BL-L-C

民用设备,工业设备
MURATA

ACA-20PC-4-AC1-PGL-C

民用设备,工业设备
MURATA

ACA-20PC-4-AC1-PGL-L-C

民用设备,工业设备
MURATA

ACA-20PC-4-AC1-RL-C

民用设备,工业设备
MURATA

ACA-20PC-4-DC1-BL-C

民用设备,工业设备
MURATA

ACA-20PC-4-DC1-BL-L-C

民用设备,工业设备
MURATA

ACA-20PC-4-DC1-PGL-C

民用设备,工业设备
MURATA