CME0505DC [MURATA]

民用设备,工业设备;
CME0505DC
型号: CME0505DC
厂家: muRata    muRata
描述:

民用设备,工业设备

文件: 总7页 (文件大小:135K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
CME Series  
s
Isolated 0.75W Single Output Isolated DC/DC Converters  
SELECTION GUIDE  
%
mV p-p  
%
V
V
mA  
mA  
pF kHrs  
Typ. Max. Typ. Max.  
10 12 15 25  
10 12 15 25  
Min. Typ.  
CME0505DC  
CME0505SC  
CME0512SC  
5
5
5
5
5
150  
150  
63  
218  
218  
195  
67  
67  
72  
70  
70  
77  
30 3400  
30 3400  
33 2200  
FEATURES  
12  
5
7
20 30  
Single Isolated output  
„
„
„
3KVDC isolation options  
1kVDC or 3kVDC option  
CME0303S3C  
CME0305S3C  
CME0505S3C  
CME0512S3C  
3.3  
3.3  
5
3.3  
5
227  
150  
150  
63  
9
9
9
5
12 15 25  
12 15 25  
12 15 25  
300  
300  
218  
200  
66  
68  
65  
70  
73  
73  
70  
75  
30 1230  
35 630  
28 2400  
30 630  
Wide temperature performance at full 1  
5
Watt load -40 C to 85C°  
5
12  
7
10 15  
Industry Standard Pinout  
3.3V and 5V Inputs  
„
„
„
„
INPUT CHARACTERISTICS  
Parameter  
Conditions  
Min.  
2.97  
4.5  
Typ.  
Max.  
3.63  
5.5  
2
Units  
V
Continuous operation, 3.3V input types  
Continuous operation, 5V input types  
3.3V input types  
3.3  
5.0  
1.5  
2
3.3V, 5V & 12V outputs  
Voltage range  
Pin Compatible with LME, MEE1, MEE3,  
Reflected ripple current  
mA  
NKE, NME, & NML series  
5V input types  
2.5  
OUTPUT CHARACTERISTICS  
PRODUCT OVERVIEW  
Parameter  
Conditions  
Min.  
Typ.  
1.0  
Max.  
0.75  
Units  
W
The CME series are a cost effective 0.75W DC/DC  
converter series, in industry standard packages  
with industry standard pinout., Popular input and  
output voltages are available as a lower power  
alternative to a 1W DC/DC converter. The galvanic  
isolation allows the device to be configured to  
provide an isolated negative rail in systems where  
only positive rails exist. The wide temperature  
range guarantees startup from –40°C and full 0.75  
watt output at 85°C.  
Rated Power  
TA=-40°C to 120°C, see derating graphs  
Voltage Set Point Accuracy See tolerance envelope  
Line regulation High VIN to low VIN  
1.2  
%/%  
ISOLATION CHARACTERISTICS  
Parameter  
Conditions  
Min.  
1000  
3000  
Typ.  
Max.  
Units  
VDC  
GΩ  
C Versions Flash tested for 1 second  
3C Versions Flash tested for 1 second  
Viso= 1000VDC  
Isolation test voltage  
Resistance  
10  
GENERAL CHARACTERISTICS  
Parameter  
Conditions  
CME0505  
Min.  
Typ.  
120  
135  
Max.  
Units  
kHz  
Switching frequency  
All other types  
ABSOLUTE MAXIMUM RATINGS  
Lead temperature 1.5mm from case for 10 seconds  
260°C  
Input voltage VIN, 3.3V input  
5.5V  
7V  
Input voltage VIN, 5V input  
1. Calculated using MIL-HDBK-217F with nominal input voltage at full load.  
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com/support  
KDC_CME.A03 Page 1 of 7  
CME Series  
Isolated 0.75W Single Output Isolated DC/DC Converters  
TEMPERATURE CHARACTERISTICS  
Parameter  
Specification  
Storage  
Conditions  
All output types  
Min.  
-40  
Typ.  
Max.  
85  
Units  
°C  
-50  
130  
41  
3.3V & 5V output types  
12V output types  
Case temperature rise above  
ambient  
32  
Cooling  
Free air convection  
TECHNICAL NOTES  
ISOLATION VOLTAGE  
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,  
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.  
Murata Power Solutions CME series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second for C versions and 3kVDC for 1  
second for 3C versions.  
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”  
For a part holding no specific agency approvals, such as the CME series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or  
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part  
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must  
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to  
safety standard requirements.  
REPEATED HIGH-VOLTAGE ISOLATION TESTING  
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,  
construction and environment. The CME series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While  
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically  
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We  
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.  
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further  
www.murata-ps.com/support  
KDC_CME.A03 Page 2 of 7  
CME Series  
Isolated 0.75W Single Output Isolated DC/DC Converters  
TEMPERATURE DERATING GRAPHS  
0303, 0305 types only.  
All other types.  
85°C  
85°C  
0.75  
0.75  
Safe Operating Area  
Safe Operating Area  
120°C  
150  
0
-40  
0
-40  
100  
150  
0
50  
100  
0
50  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
TOLERANCE ENVELOPES  
5V output types.  
3.3V output types.  
+8%  
+12%  
+8%  
+4%  
VNOM  
+3%  
VNOM  
+4%  
-0%  
-4%  
0%  
-2%  
-5%  
-10%  
100  
75  
Output Load Current (%)  
100  
10 25  
50  
75  
Output Load Current (%)  
10 25  
50  
12V output types.  
+8%  
+5%  
+3%  
+2%  
VNOM  
0%  
-3%  
100  
75  
Output Load Current (%)  
10 25  
50  
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the  
maximum output voltage variation due to changes in output loading.  
www.murata-ps.com/support  
KDC_CME.A03 Page 3 of 7  
CME Series  
Isolated 0.75W Single Output Isolated DC/DC Converters  
APPLICATION NOTES  
Minimum load  
The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in  
an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%.  
Capacitive loading and start up  
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product  
series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF.  
Typical Start-Up Wave Form  
Start-up time  
μs  
CME0505DC  
CME0505SC  
CME0512SC  
CME0303S3C  
CME0305S3C  
CME0505S3C  
CME0512S3C  
1000  
1000  
5600  
540  
1300  
1080  
5000  
Ripple & Noise Characterisation Method  
Ripple and noise measurements are performed with the following test configuration.  
C1  
C2  
1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter  
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less  
than 100mꢀ at 100 kHz  
C3  
R1  
100nF multilayer ceramic capacitor, general purpose  
450ꢀ resistor, carbon film, 1% tolerance  
R2  
50ꢀ BNC termination  
T1  
3T of the coax cable through a ferrite toroid  
RLOAD  
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires  
Measured values are multiplied by 10 to obtain the specified values.  
Differential Mode Noise Test Schematic  
DC/DC Converter  
OSCILLOSCOPE  
Y INPUT  
R2  
C1 C2 C3  
R1  
T1  
+
+
Input  
Output  
SUPPLY  
-
-
R LOAD  
www.murata-ps.com/support  
KDC_CME.A03 Page 4 of 7  
CME Series  
Isolated 0.75W Single Output Isolated DC/DC Converters  
APPLICATION NOTES (continued)  
Output Ripple Reduction  
By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max.  
Component selection  
Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended.  
The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter.  
Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor  
should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be  
>20MHz.  
L
DC  
Power  
Source  
Load  
C
DC  
Inductor  
SMD  
Capacitor  
L, μH  
47  
Through Hole  
11R473C  
11R473C  
11R683C  
11R103C  
11R473C  
11R103C  
11R683C  
C, μF  
4.7  
4.7  
1
CME0505DC  
CME0505SC  
CME0512SC  
CME0303S3C  
CME0305S3C  
CME0505S3C  
CME0512S3C  
82473C  
82473C  
82683C  
82103C  
82473C  
82103C  
82683C  
47  
68  
10  
4.7  
4.7  
4.7  
0.68  
47  
10  
68  
www.murata-ps.com/support  
KDC_CME.A03 Page 5 of 7  
CME Series  
Isolated 0.75W Single Output Isolated DC/DC Converters  
PACKAGE SPECIFICATIONS  
3C Package  
DC Package  
SC Package  
11.48  
(0.45)  
11.48  
(0.45)  
9.80 (0.386)  
CME0505DC  
6.00  
(0.236)  
6.00  
(0.236)  
XYYWW  
11.50 (0.453)  
7.46  
(0.293)  
6.80 (0.267)  
CME0505S3C  
0.55 (0.022)  
0.45 (0.018)  
10.0  
(0.393)  
XYYWW  
CME0505SC  
0.55 (0.022)  
0.45 (0.018)  
XYYWW  
1
2
3
4
4.60 (0.181)  
3.60 (0.142)  
4.60 (0.181)  
3.60 (0.142)  
1
2
3
4
0.55 (0.022)  
0.45 (0.018)  
0.50 0.05  
(0.0196 0.00196)  
4.60 (0.181)  
3.60 (0.142)  
2.54 (0.1)  
0.55 (0.022)  
0.45 (0.018)  
2.18 0.50  
(0.086 0.0197)  
1.89 (0.074)  
2.77 (0.109)  
1
4
0.30 (0.0118)  
0.20 (0.0078)  
0.30 (0.0118)  
0.20 (0.0078)  
1.09 (0.043)  
7.62 (0.3)  
1.25  
(0.049)  
1.25  
(0.049)  
7
5
0.30 (0.0118)  
0.20 (0.0078)  
5.08 (0.2)  
7.62 (0.3)  
7.62  
(0.3)  
7.62  
(0.3)  
1.94 (0.0763)  
Weight: 1.09g (3C) 1.30g (SC) 1.38g (DC)  
All dimensions in millimetres 0.25mm (“ 0.01”). All pins on a 2.54 (0.1) pitch and within 0.25 (0.01) of true position.  
PIN CONNECTIONS - 8 PIN DC  
PIN CONNECTIONS - 4 PIN 3C & SC  
Pin  
1
Function  
-VIN  
Pin  
1
Function  
-VIN  
4
+VIN  
2
+VIN  
5
+VOUT  
-VOUT  
3
-VOUT  
7
4
+VOUT  
www.murata-ps.com/support  
KDC_CME.A03 Page 6 of 7  
CME Series  
Isolated 0.75W Single Output Isolated DC/DC Converters  
PACKAGE SPECIFICATIONS (continued)  
RECOMMENDED FOOTPRINT DETAILS  
8 Pin DC Package  
4 Pin 3C & SC Package  
4 HOLES  
0.1 (0.00394)  
1.15 (0.0453)  
1.00 (0.0394)  
Ø
2.54  
(0.1)  
2.54 (0.1)  
4 HOLES  
0.1 (0.00394)  
1.15 (0.0453)  
1.00 (0.0394)  
Ø
2.54  
(0.1)  
2.54 (0.1)  
TUBE OUTLINE DIMENSIONS  
DC Tube  
SC Tube  
3C Tube  
12.0 (0.472)  
9.30 (0.366)  
7.70 (0.303)  
5.07 (0.199)  
5.10 (0.2)  
0.65 (0.026)  
4.45 (0.175)  
Unless otherwise stated all dimensions in inches (mm) 0.5mm.  
Tube length (8 Pin DIP) : 20.47 (520mm 2mm).  
5.00 (0.2)  
Tube Quantity : 40  
Tube length (4 Pin SIP) : 20.67 (525mm 2mm).  
RoHS COMPLIANCE INFORMATION  
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260°C for 10 seconds. The pin termination finish  
on the SIP package type is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both  
types in this series are backward compatible with Sn/Pb soldering systems.  
For further information, please visit www.murata-ps.com/rohs  
This product is subject to the following operating requirements  
and the Life and Safety Critical Application Sales Policy:  
Refer to: http://www.murata-ps.com/requirements/  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
ISO 9001 and 14001 REGISTERED  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
notice.  
© 2014 Murata Power Solutions, Inc.  
www.murata-ps.com/support  
KDC_CME.A03 Page 7 of 7  

相关型号:

CME0505DPC

民用设备,工业设备
MURATA

CME0505S3C

DC-DC Regulated Power Supply Module, 1 Output, 0.75W, Hybrid, SIP-4
MURATA

CME0505SC

民用设备,工业设备
MURATA

CME0505SPC

民用设备,工业设备
MURATA

CME0512S3C

民用设备,工业设备
MURATA

CME0512SC

民用设备,工业设备
MURATA

CME1-C

Single Phase EMI Filter
COILCRAFT

CME1-X

Single Phase EMI Filter
COILCRAFT

CME2-C

Single Phase EMI Filter
COILCRAFT

CME2-X

Single Phase EMI Filter
COILCRAFT

CME2425-1

SWITCHMODE/HIGH FREQUENCY - COMMON MODE INDUCTORS
TRIAD

CME2425-2

Switchmode/High Frequency Common Mode Inductors
TRIAD