D1U86-D-1600-12-HxxDC Series  
86mm 1U Front End DC-DC Power Supply Converter  
PRODUCT OVERVIEW  
The D1U86P-D-1600-12-HxxDC series are highly efficient 1600 watt, DC input front end supplies with a  
12V main output and a 12V (30W) standby. They have current sharing and up to 8 supplies may be oper-  
ated in parallel. The supplies may be hot plugged, they recover from overtemperature faults, and have  
logic and PMBus monitoring and control. Their low profile 1U package and >38.6W/cubic inch power  
density make them ideal for delivering reliable, efficient power to servers, workstations, storage systems  
and other 12V distributed power systems.  
ORDERING GUIDE  
Part Number  
Power Output  
1600W  
Main Output  
12Vdc  
Standby Output1  
12Vdc  
Airflow  
FEATURES  
  
1600W output power  
D1U86P-D-1600-12-HB4DC  
D1U86P-D-1600-12-HB3DC  
Back to front  
Front to back  
  
93% efficiency at half load  
  
12V main output  
INPUT CHARACTERISTICS  
Parameter  
  
12V standby output of 30W  
Conditions  
Min.  
-40  
-43  
Nom.  
-48  
-43.5  
-39  
Max.  
Units  
Vdc  
  
1U height: 3.4" x 7.75" x 1.59"  
Input Voltage Operating Range  
Turn-on Voltage  
Turn-off Voltage  
-72  
-44  
-39.5  
47  
50  
100  
Ramp up  
Ramp down  
Maximum Current at Vin = -40Vdc 1600W  
  
38.6 Watts per cubic inch density  
Vdc  
Adc  
Apk  
-38.5  
  
N+1 redundancy, including hot plugging (up to  
8 in parallel)  
40  
72  
DC Line Inrush Peak Current  
Efficiency (48V)  
Cold start between 0 to 200msec  
  
Current sharing on 12V main output, ORing FET  
20% load  
50% load  
100% load  
92  
93  
89  
  
Overvoltage, overcurrent,  
overtemperature protection  
%
  
Internal cooling fan (variable speed)  
OUTPUT VOLTAGE CHARACTERISTICS  
  
PMBus™ / I²C interface monitoring and control  
Output  
Parameter  
Voltage  
Conditions  
50% load  
Min.  
Typ.  
Max.  
Units  
  
RoHS compliant  
Voltage Set Point  
12.17  
11.4  
12.20  
3.10  
12.23  
12.6  
Vdc  
Line and Load Regulation  
Droop  
Ripple Voltage & Noise1  
mV/A  
mV p-p  
A
12V  
20MHz Bandwidth  
50% load  
120  
133.3  
10000  
12.03  
12.6  
Output Current  
Load Capacitance  
Voltage Set Point  
0
0
μF  
11.97  
11.4  
12.0  
120  
Vdc  
Line and Load Regulation  
Droop  
Ripple Voltage & Noise1  
mV/A  
mV p-p  
A
12VSB  
20MHz Bandwidth  
120  
2.5  
350  
Output Current  
0
0
Load Capacitance  
μF  
1
Ripple and noise are measured with 0.1 μF of ceramic capacitance and 10 μF of tantalum capacitance on each of the power supply  
outputs. A short coaxial cable with 50Ω scope termination is used.  
Available now at  
www.murata-ps.com/en/3d/acdc.html  
CB  
Test Certicate  
and Test Report  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com/support  
D1U86-D-1600-12-HxxDC.A01 Page 1 of 5  
D1U86-D-1600-12-HxxDC Series  
86mm 1U Front End DC-DC Power Supply Converter  
OUTPUT CHARACTERISTICS  
Parameter  
Output Rise Monotonicity  
Startup Time  
Conditions  
No voltage excursion  
DC ramp up  
12V, 50% load step, 1.0A/ꢀs di/dt  
12VSB, 50% load step, 1.0A/ꢀs di/dt  
At 100% load  
All outputs remain in regulation  
At full load (48V input)  
Min.  
Typ.  
Max.  
3
Units  
1.5  
600  
600  
s
Transient Response  
mV  
Current sharing accuracy (up to 8 in parallel)2  
Hot Swap Transients  
Holdup Time  
5
5
%
%
ms  
1
ENVIRONMENTAL CHARACTERISTICS  
Parameter  
Storage Temperature Range  
Operating Temperature Range  
Operating Humidity  
Storage Humidity  
Altitude (without derating at 45°C)  
Shock  
Conditions  
Min.  
-40  
0
5
5
Typ.  
Max.  
85  
55  
90  
95  
Units  
°C  
Noncondensing  
%
m
3000  
30G non operating  
Operational Vibration  
MTBF  
1G, 10-500Hz, 1.6G (non-operational)  
Per Telcordia SR-322 M1C1@ 40°C  
500K  
hrs  
CSA/UL 60950-1-07-2nd Ed.  
Safety Approvals  
IEC 60950-1:2005 (2nd Edition) w Am. 1:2009  
CE Marking per LVD DIRECTIVE 2006/95/EC  
Input Fuse  
Weight  
Power Supply has internal 60A/170VDC fast blow fuse on the DC line input  
1.108kg (2.44lbs)  
2
The load current of 100% refers to each power module max load connected in an N+1 configuration; therefore the total load will be “N” x 100% load of each module. The share accuracy of 5% is a fixed  
percentage irrespective of the total loading and number of units connected in parallel.  
PROTECTION CHARACTERISTICS  
Output  
Voltage  
Parameter  
Conditions  
Min.  
Typ.  
70  
Max.  
Units  
An OTP warning will be issued via the PMBus interface when the air inlet exceeds 70°C;  
however the power module shall not shut down until critical internal hotspot tempera-  
tures are exceeded.  
Overtemperature (intake)  
°C  
V
The unit will shut down when internal hot spot exceed the derating guide lines and auto-  
Overtemperature (hotspots) matically recovers when the unit is cooled down. The unit will shut down due to hot spot  
at ambient temperature between 55°C-60°C with main 12V at full load.  
Overvoltage  
55-60  
Latching  
13.2  
137  
14.4  
154  
For overloads (slow) over current events a 147A nominal constant current will be sus-  
tained until the output voltage drops below 3VDC. At this point the unit shall shut down  
after a 1sec period and remain in that condition for 10secs. The cycle will then repeat.  
For severe (short circuit) over current events the unit shall shut down within 1ms and  
remain in this condition for 200ms before attempting a re-start. the unit shall attempt  
10 shutdown/re-start cycles before permanently latching off. It will then be necessary to  
either recycle the DC input or toggle the PSON# input.  
12V  
Overcurrent  
Overvoltage  
Overcurrent  
Latching  
Autorecovery  
13.2  
2.75  
14.4  
3.0  
V
A
12VSB  
TBD  
ISOLATION CHARACTERISTICS  
Parameter  
Conditions  
Min.  
1500  
1500  
500  
Typ.  
Max.  
Units  
Input to Output - Basic  
Input to Chassis - Basic  
Output to Chassis  
Vdc  
Vdc  
Vdc  
Insulation Safety Rating / Test Voltage  
Isolation  
www.murata-ps.com/support  
D1U86-D-1600-12-HxxDC.A01 Page 2 of 5  
D1U86-D-1600-12-HxxDC Series  
86mm 1U Front End DC-DC Power Supply Converter  
EMISSIONS AND IMMUNITY  
Characteristic  
Standard  
Compliance  
Conducted Emissions  
ESD Immunity  
FCC 47 CFR Part 15/CISPR 22/EN55022  
IEC/EN 61000-4-2  
IEC/EN 61000-4-3  
IEC/EN 61000-4-4  
IEC/EN 61000-4-5  
IEC/EN 61000-4-6  
IEC/EN 61000-4-8  
Class A, 6dB margin  
Level 3 criteria A  
Level 3 criteria B  
Level 3 criteria A  
Level 2 criteria B  
Level 3 criteria A  
3 A/m criteria B  
Radiated Field Immunity  
Electrical Fast Transient Immunity  
Surge Immunity  
Radiated Field Conducted Immunity  
Magnetic Field Immunity  
STATUS INDICATORS AND CONTROL SIGNALS  
Signal  
Description  
PSON#  
Low = main output on; PSON# can be permanently tied to GND within the host system.  
Short pin pulled down on p/s; pulled up to either 3.3V or 12V (max) in the host system. For 3.3V use a 5.11Kꢁ resistor; for 12V  
use a 21Kꢁ resistor.  
PRESENT#  
PS INTERRUPT  
ADDR  
Open drain PMBus signal; can be left open if not used.  
PMBus Address; ADDR can be grounded or left open if not used. If grounded, the address will be 000, if it is open, the default  
address will be 111.  
ISHARE  
PSOK3  
Analog representation of main output current; can be left open if not used.  
Three level signal based on DC input and DC output status; can be left open if not used.  
I2C CLOCK  
I2C DATA  
I2C clock  
I2C data  
LED State  
Mode  
Operating Condition  
1. Off  
Input Turn-off  
Standby  
Power-good  
Warning  
Fault  
DC Input is below minimum power-supply turn-on specification  
Power supply standby output is operating within normal parameters and main output is disabled  
Power supply standby & main outputs are operating within normal parameters and delivering power  
Warning condition in power supply has been detected  
2. Green – blinking 1Hz  
3. Green – solid  
4. Yellow – blinking 1Hz  
5. Yellow – solid  
Fault condition in power supply has been detected.  
OUTPUT CONNECTOR AND SIGNAL SPECIFICATION  
Pin#  
Function  
Pin Type  
Description  
14-26, 39-51 RTN  
Power Ground Power and Standby Return  
1-13, 52-64  
37  
12V  
12VSB  
Power  
Power  
12V Output  
12V Standby Output  
Power Supply Output Card Edge  
Active low; interrupt line for power supply  
fault & warning detection as per PMBus spec  
Power Supply Present Signal (shortest pin)  
Combination of there power supply output  
indicator signals:  
64  
1
38  
36  
PSINTERRUPT Output  
PRESENT#  
Input  
35  
PSOK3  
Analog output 1. DC input OK  
2. Power Good  
3. Power Supply Fault  
Analog representation of main output current.  
Typical analog voltage shall be 60.15mV/Amp  
of main output current.  
34  
ISHARE  
Analog I/O  
33  
32  
31  
30  
29  
28  
27  
PSON#  
SCL  
SDA  
GND  
N/A  
N/A  
Input  
Input  
I/O  
Analog I/O  
N/A  
Power Supply on/off control signal  
SMBus/PMBus Clock  
SMBus/PMBus Data  
Power Supply Signal Ground  
Reserved; no User connection  
Reserved; no User connection  
PMBus Address  
33  
32  
PCB Top Side  
PCB Bottom Side  
N/A  
Analog input  
ADDR  
CONNECTOR AND SIGNAL SPECIFICATION3 PSOK TRUTH TABLE VS. ANALOG OUTPUT  
DC_OK_H  
PWR_GOOD_H  
PS_FAULT_L  
PSOK  
OPERATION MODE  
No DC Input  
Invalid  
0
0
1
1
X
0
1
0
1
X
1
1
1
1
0
< 0.1Vdc  
(1/3) VDD  
(2/3) VDD  
VDD  
VDD = 3.3Vdc Standby  
Power Good  
0.2-0.4Vdc  
PS Fault  
www.murata-ps.com/support  
D1U86-D-1600-12-HxxDC.A01 Page 3 of 5  
D1U86-D-1600-12-HxxDC Series  
86mm 1U Front End DC-DC Power Supply Converter  
WIRING DIAGRAM FOR OUTPUT  
1-13, 52-64  
1-13, 52-64  
Main output  
load  
RTN  
RTN 14-26, 39-51  
14-26, 39-51  
D1U86  
D1U86  
12VSB  
12VSB  
37  
37  
PSON#  
RTN  
PSON#  
33  
33  
VSB load  
FET,BJT,wire  
FET,BJT,wire  
or switch (debounced)  
to turn on 12V main  
output  
or switch (debounced)  
to turn on 12V main  
output  
RTN  
CURRENT SHARING NOTES  
Main Output: Current share is achieved using the droop method. Nominal output voltage (12.20V) is achieved at 50% load and output voltage changes at a rate of  
3.10mv per amp. Startup of parallel power supplies is not internally synchronized. If more than 1600W combined power is needed, start-up synchronization must  
be provided by using a common PS_ON signal. To account for 5% full load current sharing accuracy and the reduction in full load output voltage due to droop,  
available output power must be derated by 10% when units are operated in parallel. Internal ORing FETs are provided.  
Standby output can be tied together for redundancy but total combined output power must not exceed 30W; Internal MOSFET ORing devices are used.  
www.murata-ps.com/support  
D1U86-D-1600-12-HxxDC.A01 Page 4 of 5  
D1U86-D-1600-12-HxxDC Series  
86mm 1U Front End DC-DC Power Supply Converter  
MECHANICAL DIMENSIONS  
197.70 ±0.65  
9.00 ±0.30  
230.41 REF  
198.05 0.65  
AIRFLOW FRONT TO BACK  
AIRFLOW BACK TO FRONT  
41.90  
86.40 ±0.60  
10.25 0.40  
DC input connector: Terminal Block, Dinkle Enterprise: Part No. DT-7C-B14W-02  
Dimensions: 3.4" x 7.75" x 1.59" [86mm x 196.85mm x 39.9mm]  
MATING CONNECTOR  
Part Number  
Description  
FCI 10053363-200LF  
FCI 10046971-008LF  
Right Angle  
Vertical  
OPTIONAL ACCESSORIES  
Description  
Part Number  
12V D1U86P Output Connector Card  
D1U86P-12-CONC  
APPLICATION NOTES  
Document Number  
ACAN-50  
Description  
D1U86P Output Connector Card  
D1U86P Communication Protocol  
ACAN-54  
This product is subject to the following operating requirements  
and the Life and Safety Critical Application Sales Policy:  
Refer to: http://www.murata-ps.com/requirements/  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
ISO 9001 and 14001 REGISTERED  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
notice.  
© 2015 Murata Power Solutions, Inc.  
www.murata-ps.com/support  
D1U86-D-1600-12-HxxDC.A01 Page 5 of 5  

相关型号:

D1UB80

General Purpose Rectifiers(800V 1A)
SHINDENGEN

D1UBA05

0.8A SURFACE MOUNT GLASS PASSIVATED BRIDGE RECTIFIER
SENO

D1UBA10

0.8A SURFACE MOUNT GLASS PASSIVATED BRIDGE RECTIFIER
SENO

D1UBA100

0.8A SURFACE MOUNT GLASS PASSIVATED BRIDGE RECTIFIER
SENO

D1UBA20

0.8A SURFACE MOUNT GLASS PASSIVATED BRIDGE RECTIFIER
SENO

D1UBA40

0.8A SURFACE MOUNT GLASS PASSIVATED BRIDGE RECTIFIER
SENO

D1UBA60

0.8A SURFACE MOUNT GLASS PASSIVATED BRIDGE RECTIFIER
SENO

D1UBA80

0.8A SURFACE MOUNT GLASS PASSIVATED BRIDGE RECTIFIER
SENO
SHINDENGEN

D2

Optoelectronic
ETC

D2-1

Optoelectronic
ETC

D2-1-37

GENERAL-PURPOSE PHOTOVOLTAIC CELL
ETC