EUS30-080-PHBR [MURATA]

DC-DC Unregulated Power Supply Module, 1 Output, 220W, Hybrid,;
EUS30-080-PHBR
型号: EUS30-080-PHBR
厂家: muRata    muRata
描述:

DC-DC Unregulated Power Supply Module, 1 Output, 220W, Hybrid,

文件: 总7页 (文件大小:182K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
BUS CONVERTER  
EUS30-080 Model  
PRELIMINARY  
Features:  
9
48 Vin, Isolated, 6:1 Fixed Conversion Ratio  
(8.0V Nominal Output)  
9
9
9
9
9
9
220 Watt Nominal Output (at 48 Vin, 55 C, 200 LFM)  
170 Watt Output at 38 Vin, 55 C, 200 LFM  
Industry Standard 1/8 Brick Footprint  
Remote Enable (Primary Side, Positive or Negative)  
Over-temperature and Over Current Protection  
Direct Parallel Operation for Higher Power Applications  
CISCO PART NUMBER: EUS30-080-NHxRCA  
Table 1  
Input Characteristics  
Notes & Conditions (1)  
Min  
Typ.  
Max  
Units  
Vdc  
Input Voltage Operating Range  
Input Voltage Absolute Maximum  
36  
48  
55  
60  
37.5  
35.5  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Adc  
mA  
Turn-on Threshold  
Turn-off Threshold  
Hysteresis Voltage  
Turn-on Threshold  
Turn-off Threshold  
Hysteresis Voltage  
Steady-State (30 A out)  
Enabled state, no load (48 Vin)  
Disabled state (48 Vin)  
Measured with test circuit TBD  
36  
34  
Input Undervoltage Lockout  
Input Overvoltage Lockout  
2
56  
55  
58  
57  
2
Maximum Input Current  
No-Load Input Current  
Disabled Input Current  
Input Reflected Ripple Current  
Inrush Current Transient  
5.4  
70  
7
25  
0.2  
mA  
50  
mA p-p  
A2s  
Enable – Negative Logic Version  
Internal 10 K pull-up to 5 V.  
On State range  
Off State range  
-0.1  
2.4  
0.8  
5.0  
Vdc  
Vdc  
Enable – Positive Logic Version  
Internal 100 K pull-down to GND.  
On State range  
Off State range  
2.4  
5.0  
0.8  
Vdc  
Vdc  
-0.1  
Table 2  
Output Characteristics  
Notes & Conditions (1)  
Min  
Typ.  
Max  
Units  
Output Voltage Set Point (Vo=Vin/6 +0/-0.5%)  
Output Load Regulation  
Vin = 48.0 V, Io = 0 A  
Io = 0 to 30 A  
8.0  
0.5  
Vdc  
V
Output Voltage Total Regulation  
Vin = 36 to 55 V, Io = 0 to 30 A  
Vin = 42 to 53 V, Io = 0 to 30 A  
20 MHz Bandwidth  
5.3  
6.3  
9.2  
8.9  
150  
30  
Vdc  
Vdc  
mV p-p  
A
Output Ripple Voltage & Noise (2)  
Output Current Operating Range  
Efficiency  
Turn-On Time  
Start-up Inhibit Time  
70  
0
Vin = 48 V, Io = 18 A  
95.6  
10  
120  
130  
%
Vin present: Enable to 90% Vout  
Enabled: Vin applied to 90% Vout  
25% step, 0.1A/µs, Vo  
Recovery Time  
mS  
mS  
mV  
µs  
Transient Response (3)  
100  
Maximium Output Capacitance  
3000  
µF  
Celestica Power Systems  
Innovative Solutions You Can Count On  
1150 Eglinton Aveune East  
Toronto, Ontario M3C 1H7  
1-866-740-1232  
4607 S.E. International Way  
Milwaukie, Oregon 97222  
1-971-206-2800  
www.celesticapower.com  
EUS30-080 6200561446-A02_27May04  
Page 1  
BUS CONVERTER  
EUS30-080 Model  
Table 3  
Protection Characteristics  
Output Over-Current Shutdown  
Notes & Conditions (1)  
Min  
Typ.  
Max  
Units  
Non-Latching  
Re-start rate  
Peak  
32  
35  
80  
TBD  
125  
10  
40  
A
msec  
Ap  
°C  
Short Circuit Current  
Over Temperature Shutdown  
Over Temperature Restart Hysteresis  
Non-Latching (4)  
130  
°C  
Table 4  
General Specifications  
Notes & Conditions (1)  
Min  
Typ.  
Max  
Units  
Isolation Voltage  
Isolation Resistance  
Storage Temperature Range  
Operating Temperature Range  
Thermal Measurement Location Temperature (6)  
Material Flammability  
Input to Output  
Input to Output  
2250  
10  
-40  
-40  
Vdc  
Mohm  
°C  
°C  
°C  
125  
85  
120  
Non-condensing (6)  
See mechanical drawing for location  
UL 94V-0  
Calculated (Bellcore TR-332)  
Demonstrated  
1
TBD  
TBD  
x106 Hrs  
x106 Hrs  
MTBF  
2.28”L x 0.9”W x 0.48”H (max)  
Dimensions  
Weight  
(57.9L x 22.9W x 12.19H mm max)  
grams  
Table 5  
Standards Compliance  
Notes & Conditions (5)  
UL/CSA 60950  
EN60950  
Basic Insulation, (pending)  
Certified by TUV (pending)  
Notes:  
(1) Vin = 48Vdc, Ta = 25 °C, Airflow = 200 LFM for all data unless otherwise noted.  
(2) Output Ripple Voltage and noise is specified when measured with no external capacitance.  
(3) Transient response is specified without a capacitor at the output of the converter.  
(4) Thermal shutdown is monitored at the Thermal Measurement Location (TML). See ‘Mechanical Information’ on page 3 for TML  
location.  
(5) See ‘Safety Considerations’ shown in Figure 12.  
(6) De-rating curves are conducted in a controlled environment. End application testing is required to ensure the Thermal Measurement  
Location temperature is below the maximum specified. Recommended airflow direction is from pin 1 to pin 3, or 3 to 1 (transverse to  
the unit)  
Celestica Power Systems  
Innovative Solutions You Can Count On  
1150 Eglinton Aveune East  
Toronto, Ontario M3C 1H7  
1-866-740-1232  
4607 S.E. International Way  
Milwaukie, Oregon 97222  
1-971-206-2800  
www.celesticapower.com  
EUS30-080 6200561446-A02_27May04  
Page 2  
BUS CONVERTER  
EUS30-080 Model  
Mechanical Information  
Figure 1  
Pin Assignment  
Table 6  
Pin #  
Pin Name  
Function  
Notes & Conditions  
1
Vi(+)  
Positive Input Voltage  
Referenced to Vi(-).  
2
En  
Input Enable / Disable  
Positive Logic: Floating = Enabled  
Negative Logic: Floating = Disabled  
3
4
5
Vi(-)  
Vo(-)  
Vo(+)  
Negative Input Voltage  
Negative Output Voltage  
Positive Output Voltage  
Celestica Power Systems  
Innovative Solutions You Can Count On  
1150 Eglinton Aveune East  
Toronto, Ontario M3C 1H7  
1-866-740-1232  
4607 S.E. International Way  
Milwaukie, Oregon 97222  
1-971-206-2800  
www.celesticapower.com  
EUS30-080 6200561446-A02_27May04  
Page 3  
BUS CONVERTER  
EUS30-080 Model  
Efficiency Curves  
EUS30-080 Efficiency (%) vs. Iout (A) and Vin (V)  
97%  
96%  
95%  
94%  
93%  
92%  
91%  
90%  
89%  
88%  
55Vin  
48Vin  
42Vin  
38Vin  
0
5
10  
15  
20  
25  
30  
35  
Figure 2  
Output Voltage vs. Current  
EUS30-080 Output Voltage (V) vs. Current (A) and  
Vin (V)  
10  
9
8
7
6
55 Vin  
48 Vin  
42 Vin  
38 Vin  
5
4
3
0
5
10  
15  
20  
25  
30  
Figure 3  
Celestica Power Systems  
Innovative Solutions You Can Count On  
1150 Eglinton Aveune East  
Toronto, Ontario M3C 1H7  
1-866-740-1232  
4607 S.E. International Way  
Milwaukie, Oregon 97222  
1-971-206-2800  
www.celesticapower.com  
EUS30-080 6200561446-A02_27May04  
Page 4  
BUS CONVERTER  
EUS30-080 Model  
Thermal Derating Curves (Transverse) Tcase=120C  
EUS30-080 Iout (A) vs. Tamb (C) and Air Flow  
EUS30-080 Iout (A) vs. Tamb (C) and Air Flow  
(LFM) 48 Vin  
(LFM) 38 Vin  
35  
35  
30  
25  
20  
15  
10  
5
30  
25  
20  
15  
10  
5
400 LFM  
300 LFM  
200 LFM  
100 LFM  
400 LFM  
300 LFM  
200 LFM  
100 LFM  
0
0
25  
35  
45  
55  
65  
75  
85  
25  
35  
45  
55  
65  
75  
85  
Figure 4  
Figure 5  
EUS30-080 Pout (W) vs. Tamb (C) 48 Vin (V)  
Air Flow @ 200 LFM  
275  
250  
225  
200  
175  
150  
125  
100  
75  
55Vin  
48Vin  
38Vin  
50  
25  
0
25  
35  
45  
55  
65  
75  
85  
Figure 6  
Celestica Power Systems  
Innovative Solutions You Can Count On  
1150 Eglinton Aveune East  
Toronto, Ontario M3C 1H7  
1-866-740-1232  
4607 S.E. International Way  
Milwaukie, Oregon 97222  
1-971-206-2800  
www.celesticapower.com  
EUS30-080 6200561446-A02_27May04  
Page 5  
BUS CONVERTER EUS18-080  
48 Vin, 8 Vout at 18 A  
Turn-on from Vin (Enable On)  
Turn-on from Enable (Vin present)  
Figure 7  
Ch3: Vin; Ch2: Vout  
Figure 8  
Ch3: Enable; Ch2: Vout  
Vin=48V, Io=30A, Co=3000uF  
Vin=48V, Io=30A, Co=3000uF  
Output Ripple/Noise  
Figure 9  
Vin=48V, Io=20A  
Celestica Power Systems  
Innovative Solutions You Can Count On  
1150 Eglinton Aveune East  
Toronto, Ontario M3C 1H7  
1-866-740-1232  
4607 S.E. International Way  
Milwaukie, Oregon 97222  
1-971-206-2800  
www.celesticapower.com  
EUS30-080 6200561446-A02_27May04  
Page 6  
BUS CONVERTER EUS18-080  
48 Vin, 8 Vout at 18 A  
Safety Considerations  
The EUS series of converters are certified to the standards listed in the ‘Standards Compliance’ section in the table above. If this product  
is built into information technology equipment, the installation must comply with the above standard.  
An external input fuse (TBD A recommended), must be used to meet the above requirements.  
The output of the converter [Vo(+)/Vo(-)] is considered to remain within SELV limits when the input to the converter meets SELV or TNV-  
2 requirements.  
The converters and materials meet UL 94V-0 flammability ratings.  
Figure 12  
Ordering Information  
EUS30-080-xHyR  
_ _ _ __ ___ _ _ _ _  
Eighth Brick  
Unregulated  
Single Output  
Output Current  
R = Reserved for internal use  
“y” = Model Options: B = 0.145”  
C = 0.200”  
H = Horizontal Mount  
“x” Enable Logic: N = Negative, P = Positive  
Output Voltage  
TMCelestica is a trademark of Celestica, Inc.  
Copyright Celestica, Inc. 2004  
The information provided is believed to be accurate and reliable. Celestica reserves the right to make changes to the product described  
without notice. No liability is assumed as a result of its use nor any infringement on the rights of others.  
Celestica Power Systems  
Innovative Solutions You Can Count On  
1150 Eglinton Aveune East  
Toronto, Ontario M3C 1H7  
1-866-740-1232  
4607 S.E. International Way  
Milwaukie, Oregon 97222  
1-971-206-2800  
www.celesticapower.com  
EUS30-080 6200561446-A02_27May04  
Page 7  

相关型号:

EUS30-080-PHBRC

DC-DC Regulated Power Supply Module, 1 Output, 220W, Hybrid, ROHS COMPLIANT, ONE EIGHTH BRICK PACKAGE-5
MURATA

EUS30-080-PHCR

DC-DC Unregulated Power Supply Module, 1 Output, 220W, Hybrid,
MURATA

EUS30-080-PHCRC

DC-DC Regulated Power Supply Module, 1 Output, 220W, Hybrid, ROHS COMPLIANT, ONE EIGHTH BRICK PACKAGE-5
MURATA

EUS34-096-NHARC

DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, ROHS COMPLIANT, 1/8TH BRICK PACKAGE-5
MURATA

EUS34-096-NHBRC

DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, ROHS COMPLIANT, 1/8TH BRICK PACKAGE-5
MURATA

EUS34-096-NHCRC

DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, ROHS COMPLIANT, 1/8TH BRICK PACKAGE-5
MURATA

EUS34-096-PHARC

DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, ROHS COMPLIANT, 1/8TH BRICK PACKAGE-5
MURATA

EUS34-096-PHBRC

DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, ROHS COMPLIANT, 1/8TH BRICK PACKAGE-5
MURATA

EUS34-096-PHCRC

DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, ROHS COMPLIANT, 1/8TH BRICK PACKAGE-5
MURATA

EUT1081

±1°C, Remote and Local Temperature Sensor with SMBus Series Interface
ETC

EUT1081A

±1°C, Remote and Local Temperature Sensor with SMBus Series Interface
ETC

EUT1086

±1°C, SMBus-Compatible Remote/Local Temperature Sensors with Overtemperature Alarms
ETC