HL01U12S05H [MURATA]
DC-DC Unregulated Power Supply Module, ROHS COMPLIANT, DIP-24;型号: | HL01U12S05H |
厂家: | muRata |
描述: | DC-DC Unregulated Power Supply Module, ROHS COMPLIANT, DIP-24 光电二极管 |
文件: | 总4页 (文件大小:100K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Product Data Sheet
1 WATT UNREGULATED
DC/DC CONVERTER
HL01U
FEATURES
L LOW COST
L HIGH EFFICIENCY
L
INTERNAL FILTERING
L
L
NON-CONDUCTIVE CASE
L SURFACE MOUNT CONSTRUCTION
SURFACE MOUNT PACKAGE (SMD)
L
TEMPERATURE RANGE: -25°C TO +70°C
DESCRIPTION
manufacturing technologies.
The HL01U Series offers an extensive selection of input and
output voltages to choose from. These miniature, unregulated
DC/DC converters come in 24-pin DIP and SMD packages.
This small size is possible through the use of surface mount
TheHL01USeriesutilizesa125KHzpush-pulloscillatorinthe
input stage with internal filtering to reduce the output noise.
The use of surface mount construction and automated manu-
facturing processes increase consistency and reliability while
reducing overall cost.
ORDERING INFORMATION
ABSOLUTE MAXIMUM RATINGS
HL01U xxyzz Y/Z /H
Internal Power Dissipation..................................................................30 Sec
Short Circuit Duration..................................................................Momentary
Device Family
HL Indicates DC/DC Converter
Model Number
Where:
xx = Input Voltage
Lead Temperature (soldering, 10 seconds max)..............................+300°C
*
*
Note: Refer to Reflow Profile for SMD Models.
y = Number or Outputs (Single "S", Dual "D")
zz = Output Voltage
Package Option
Screening Option
DIP Package only
HL01U revE, 12/08
Page 1
ELECTRICAL SPECIFICATIONS
Specifications typical at T = +25°C, nominal input voltage, rated output current unless otherwise specified.
A
NOMINAL
RATED
RATED
INPUT CURRENT
NO LOAD
INPUT
OUTPUT
OUTPUT
CURRENT
VOLTAGEVOLTAGE
RATED LOAD
(mA) (%)
EFFICIENCY
MODEL
(VDC)
(VDC)
(mA)
(mA)
HL01U05S05
HL01U05S12
HL01U05S15
5
5
5
5
12
15
200
83
67
30
30
30
300
260
260
70
74
74
HL01U12S05
HL01U12S12
HL01U12S15
12
12
12
5
12
15
200
83
67
25
25
25
120
120
120
67
70
70
HL01U15S05
HL01U15S12
HL01U15S15
15
15
15
5
12
15
200
83
67
20
20
20
100
100
100
67
70
70
HL01U24S05
HL01U24S12
HL01U24S15
24
24
24
5
12
15
200
83
67
15
15
15
65
65
65
67
70
70
HL01U05D05
HL01U05D12
HL01U05D15
5
5
5
5
12
15
100
41
33
30
30
30
300
260
260
70
74
74
HL01U12D05
HL01U12D12
HL01U12D15
12
12
12
5
12
15
100
41
33
25
25
25
120
120
120
67
70
70
HL01U15D05
HL01U15D12
HL01U15D15
15
15
15
5
12
15
100
41
33
20
20
20
100
100
100
67
70
70
HL01U24D05
HL01U24D12
HL01U24D15
24
24
24
5
12
15
100
41
33
15
15
15
65
65
65
67
70
70
COMMON SPECIFICATIONS
Specifications typical at T = +25°C, nominal input voltage, rated output current unless otherwise specified.
A
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT
Voltage Range
4.5
10.8
13.5
22.6
5
5.5
13.2
16.5
26.4
100
VDC
12
15
24
30
VDC
mAp-p
Reflected Ripple Current
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
500
500
VDC
Vpk
G7
pF
μArms
60 Hz, 10 Seconds
VISO= 240VAC, 60Hz
1
25
2
OUTPUT
Rated Power
1
3
0.02
50
10
1
W
%
%/°C
mVp-p
mVrms
%/%
Voltage Setpoint Accuracy
Temperature Coefficent
Ripple & Noise
5
100
1.5
BW = DC to 10MHz
BW =10Hz to 2MHz
High Line to Low Line
Line Regulation
Load Regulation
5 Vout Models
All Others
25% Rated Load to Rated Load
10% Rated Load to Rated Load
5
3
10
10
%
%
GENERAL
Switching Frequency
Package Weight
125
12
kHz
g
MTTF per MIL-HDBK-217, Rev. F
Ground Benign
Circuit Stress Method
TA = +25°C
1100
550
kHr
kHr
T = +70°C
A
TEMPERATURE
Specification
Operation
-25
-40
-40
+70
+85
+110
°C
°C
°C
Storage
Page 2
HL01U revE,12/08
Package/Pinout "Y" and "Z"
MECHANICAL
TOP VIEWS
HL01UxxyzzY
HL01UxxyzzZ
SIDE VIEWS
END VIEWS
DIP PACKAGE
SMD PACKAGE
NU = Do Not Use.
NC = No Internal Connection.
PIN CONNECTIONS
Duplicate pin functions are internally connected.
All dimensions are in inches (millimeters).
GRID: 0.100 inches (2.54 millimeters)
PIN# SINGLES DUALS
1
2
3
+VIN
NU
NU
+VIN
-VOUT
Common
TypicallyMarkedwith:specificmodelordered,date
code, job code and Logo.
10
11
12
-VOUT
+VOUT
-VIN
Common
+VOUT
-VIN
13
14
15
-VIN
+VOUT
-VOUT
-VIN
+VOUT
Common
22
23
NU
NU
Common
-VOUT
24
+VIN
+VIN
RECOMMENDED LAND PATTERN
RECOMMENDED REFLOW PROFILE
HL01U revE, 12/08
Page 3
TYPICAL PERFORMANCE CURVES
SAFE OPERATING AREA
NOTES:
1.) When operated within the SAFE OPERATING AREA as defined
by the above curves, the output voltage of HL01U devices is
guaranteedtobewithin95%ofitssteady-statevaluewithin100
milliseconds after the input voltage has reached 95% of its steady-
state value.
2.)
For dual output models, total load capacitance is the sum
of the capacitances on the plus and minus outputs.
USA:
Mansfield (MA), Tel: (508) 339 3000, email: sales@murata-ps.com
Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com
Murata Power Solutions, Inc.
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Germany: München, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 & ISO 14001 REGISTERED
Japan:
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com
China:
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com
notice.
© 2008 Murata Power Solutions, Inc.
Page 4
HL01U revE,12/08
相关型号:
©2020 ICPDF网 联系我们和版权申明