HPQ-3.3/50-D48PL2-C [MURATA]

DC-DC Regulated Power Supply Module, 1 Output, 165W, Hybrid, PACKAGE-8;
HPQ-3.3/50-D48PL2-C
型号: HPQ-3.3/50-D48PL2-C
厂家: muRata    muRata
描述:

DC-DC Regulated Power Supply Module, 1 Output, 165W, Hybrid, PACKAGE-8

文件: 总11页 (文件大小:280K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
HPQ-3.3/50-D48 Series  
Isolated High Power Quarter Brick DC-DC Converters  
s
Typical unit  
FEATURES  
PRODUCT OVERVIEW  
  
Unique among quarter-brick DC-DC converters,  
the HPQ-3.3/50-D48 series offers very high output  
current (up to 50 Amps) in an industry standard  
“quarter brick” package requiring no heat sink. The  
HPQ-3.3/50-D48 series delivers up to 165 Watts  
shutdown, an external remote On/Off control may  
use either positive or negative polarity. Remote  
Sense inputs compensate for resistive line drops at  
high currents.  
3.3 Volts DC fixed output up to 50 Amps  
  
Industry standard quarter brick 2.3" x 1.45" x  
0.40" open frame package  
  
Wide range 36 to 75 Vdc input voltages with 2250  
Volt Basic isolation  
A wealth of self-protection features avoid prob-  
fixed voltage output for printed circuit board mount- lems with both the converter and external circuits.  
  
Double lead-free assembly and attachment for RoHS  
standards  
ing. Wide range inputs on the 2.3" x 1.45" x 0.40"  
converter are 36 to 75 Volts DC (48 Volts nominal),  
ideal for datacom and telecom systems. The fixed  
output voltage is regulated to within 1ꢀ and may  
be trimmed within 10ꢀ of nominal output.  
Advanced automated surface mount assembly  
and planar magnetics deliver full magnetic and  
optical isolation with Basic protection up to 2250  
Volts. To power digital systems, the outputs offer  
fast settling to current steps and tolerance of  
higher capacitive loads. Excellent ripple and noise  
These include input undervoltage lockout and  
overtemperature shutdown using an on-board tem-  
perature sensor. Excessive overcurrents limit their  
power using the “hiccup” autorestart technique  
and the outputs may be short-circuited indefinitely.  
Additional safety features include output overvolt-  
age protection and reverse conduction elimination.  
The synchronous rectifier topology offers high  
efficiency for minimal heat buildup and “no heat  
sink” operation. The HPQ-3.3/50-D48 series meets  
safety certifications to UL/EN/IEC/CSA 60950-1,  
  
Up to 165 Watts total output power  
  
High efficiency synchronous rectifier topology  
  
Stable no-load operation with no required external  
components  
  
Operating temperature range -40 to +85° C. with  
no heat sink required  
  
Meets UL/EN 60950-1, CSA-C22.2 No. 60950-1,  
safety approvals, 2nd Edition  
specifications assure compatibility to CPU’s, ASIC’s, 2nd Edition and RFI/EMI conducted/radiated  
programmable logic and FPGA’s. No minimum load emission compliance to EN55022-CISPR22 with  
is required. For systems needing controlled startup/ external filter.  
  
Extensive self-protection, current limiting and shut  
down features  
APPLICATIONS  
  
  
Instrumentation systems, R&D platforms, auto-  
Embedded systems, datacom and telecom  
installations  
  
mated test fixtures  
  
Disk farms, data centers and cellular repeater sites  
Data concentrators, voice forwarding and  
speech processing systems  
  
Remote sensor systems, dedicated controllers  
+SENSE  
(7)  
+VIN  
(1)  
+VOUT  
(8)  
SWITCH  
CONTROL  
−VOUT  
(4)  
–VIN  
(3)  
−SENSE  
(5)  
INPUT UNDERVOLTAGE, INPUT  
OVERVOLTAGE, AND OUTPUT  
OVERVOLTAGE COMPARATORS  
PULSE  
TRANSFORMER  
PWM  
CONTROLLER  
OPTO  
ISOLATION  
REFERENCE &  
ERROR AMP  
VOUT TRIM  
(6)  
REMOTE  
ON/OFF  
CONTROL  
(2)  
Figure 1. Simplified Schematic  
Typical topology is shown  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com/support  
MDC_HPQ-3.3/50-D48 Series.B01 Page 1 of 11  
HPQ-3.3/50-D48 Series  
Isolated High Power Quarter Brick DC-DC Converters  
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE  
Output  
Input  
R/N (mV  
pk-pk)  
Regulation  
(Max.)  
Efficiency  
Package  
Dimensions  
(mm)  
IOUT  
IIN full  
load  
VOUT (Amps, Power  
VIN Nom. Range  
IIN no  
Dimensions  
(inches)  
(Volts) max.) (Watts) Typ. Max. Line Load (Volts) (Volts) load (mA) (Amps) Min. Typ.  
Pinout  
Root Model ➀  
HPQ-3.3/50-D48  
3.3 50 165 50 100 0.2ꢀ 0.2ꢀ 48 36-75 80 3.82  
88ꢀ 90ꢀ 1.45x2.3x0.40 36.8x58.4x10.2 P32  
Please refer to the part number structure for additional ordering information and options.  
All specifications are at nominal line voltage and full load, +25 deg.C. unless otherwise noted. See detailed specifications. Output capacitors are 1 μF ceramic || 10 μF electrolytic with no input caps.These  
caps are necessary for our test equipment and may not be needed for your application.  
PART NUMBER STRUCTURE  
HPQ - 3.3 / 50 D48 N B  
H
Lx - C  
-
RoHS Hazardous Materials compliance  
C = RoHS-6 (does not claim EU RoHS exemption 7b–lead in solder), standard  
Y = RoHS-5 (with lead), optional, special quantity order  
Family  
Series:  
High Power  
Pin length option  
Blank = standard pin length 0.180 in. (4.6 mm)  
L1 = 0.110 in. (2.79 mm)*  
Quarter Brick  
Nominal Output Voltage  
L2 = 0.145 in. (3.68 mm)*  
*Special quantity order is required;  
no sample quantities available.  
Conformal coating (optional)  
Maximum Rated Output :  
Current in Amps  
Blank = no coating, standard  
H = Coating added, optional, special quantity order  
Input Voltage Range:  
D48 = 36-75 Volts (48V nominal)  
Baseplate (optional)  
Blank = No baseplate, standard  
B = Baseplate installed, optional quantity order  
Note:  
On/Off Control Polarity  
Some model number combinations  
may not be available. Please contact  
Murata Power Solutions.  
N = Negative polarity, standard  
P = Positive polarity, optional  
www.murata-ps.com/support  
MDC_HPQ-3.3/50-D48 Series.B01 Page 2 of 11  
HPQ-3.3/50-D48 Series  
Isolated High Power Quarter Brick DC-DC Converters  
FUNCTIONAL SPECIFICATIONS  
Absolute Maximum Ratings  
Input Voltage  
Continuous  
75 Volts max.  
100 Volts max.  
Transient, 100 mS max.  
Output Power  
166.6 Watts max.  
On/Off Control  
0V. min. to +15 V. max.  
None. Install external fuse.  
Input Reverse Polarity Protection  
Current-limited.  
Devices can withstand sustained short circuit without damage.  
Output Current  
Storage Temperature  
Lead Temperature  
-55 to +125 °C  
See soldering guidelines.  
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions  
other than those listed in the Performance/Functional Specifications Table is not implied nor recommended.  
All specifications are typical unless noted. See Note 1.  
Input  
Input Voltage Range  
See Ordering Guide.  
10 Amps fast blow  
33.0 Volts  
Recommended External Fuse  
Start-Up Voltage  
Undervoltage Shutdown  
Overvoltage Shutdown  
Reflected (Back) Ripple Current (Note 2)  
Internal Input Filter Type  
Reverse Polarity Protection (Note 15)  
Input Current:  
32.0 Volts  
None, see application notes.  
20 mA pk-pk  
Pi-type  
None. Install external fuse.  
Full Load Conditions  
See Ordering Guide.  
0.05 A2Sec.  
10 mA  
Inrush Transient  
Shutdown Mode (Off, UV, OT)  
Output Short Circuit  
50 mA  
No Load, 3.3Vout  
80 mA  
Low Line (Vin=Vmin, 3.3Vout)  
Remote On/Off Control (Note 5)  
5.21 Amps  
ON = +2.5 V. to +15 V. max. or open pin  
OFF = 0 to +1 V. max. or ground pin  
Positive Logic (“P” suffix)  
ON = -0.1 V. to +0.8 V. max. or ground pin  
OFF = +2.5 V. to +15 V. max. or open pin  
Negative Logic (“N” suffix)  
Current  
1 mA  
www.murata-ps.com/support  
MDC_HPQ-3.3/50-D48 Series.B01 Page 3 of 11  
HPQ-3.3/50-D48 Series  
Isolated High Power Quarter Brick DC-DC Converters  
Output  
Minimum Loading  
No minimum load  
166.6 Watts  
Maximum Output Power  
Accuracy (50ꢀ load)  
1 ꢀ of Vsetting. See note 16.  
4 Volts  
Overvoltage Protection (Note 7)  
Temperature Coefficient  
Ripple/Noise (20 MHz bandwidth)  
Line/Load Regulation (See Tech. Notes)  
Efficiency  
0.02ꢀ per °C. of Vout range  
See Ordering Guide and note 8.  
See Ordering Guide and note 10.  
See Ordering Guide  
Remote Sense Compensation  
Maximum Capacitive Loading, low ESR  
Current Limit Inception (98ꢀ of Vout setting)  
Short Circuit Mode (Notes 6, 12)  
Short Circuit Current Output  
Protection Method  
+10ꢀ max. deviation from output  
10,000 μF max. See note 11.  
59 Amps (after warm up) See note 12.  
5 Amps  
Hiccup autorecovery upon overload removal. (See note 12)  
Continuous, no damage (output shorted to ground)  
Short Circuit Duration  
Isolation  
Isolation Voltage  
Input to Output  
2250 Vdc min.  
1500 Vdc min.  
1500 Vdc min.  
10 Megohms  
1000 pF  
Input to Baseplate  
Baseplate to Output  
Isolation Resistance  
Isolation Capacitance  
Isolation Safety Rating  
Basic insulation  
Dynamic Characteristics  
Dynamic Load Response (see note 1)  
Turn-On Time  
200 μSec to within 1ꢀ of final value. (50-75-50ꢀ load step)  
10 mSec for Vout regulated  
Remote On/Off Time  
10 mSec for Vout regulated  
Switching Frequency  
400 40 ꢁHz  
Environmental  
Calculated MTBF (Note 4)  
Operating Temperature Range (no baseplate)  
Maximum Baseplate Operating Temperature  
Storage Temperature Range  
TBC  
-40 to +85 °C (with derating)  
+100 °C  
-55 to +125 °C  
Thermal Protection/Shutdown  
(Case temp. is measured in the center)  
+115 °C  
Relative Humidity  
Physical  
85ꢀ/+85 °C  
Outline Dimensions  
Weight (without baseplate)  
See Mechanical Specifications  
1.06 ounces (30 grams)  
Electromagnetic Interference  
(may require external filter)  
Meets EN55022, CISPR22, Class B,  
conducted and radiated  
Meets UL/cUL 60950-1  
CSA-C22.2 No. 60950-1  
IEC/EN 60950-1, 2nd Edition  
Safety  
www.murata-ps.com/support  
MDC_HPQ-3.3/50-D48 Series.B01 Page 4 of 11  
HPQ-3.3/50-D48 Series  
Isolated High Power Quarter Brick DC-DC Converters  
Specification Notes  
(1) All models are tested and specified with external 1||10 μF output capacitors and no external input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate our test equip-  
ment and may not be required to achieve specified performance in your applications. All models are stable and regulate within spec under no-load conditions.  
All specifications are typical unless noted. General conditions for Specifications are +25 °C, Vin=nominal, Vout=nominal, full load. Adequate airflow must be supplied for extended testing under power.  
(2) Reflected Input Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is Cin=33 μF, 100V, Cbus=220 μF, 100V electrolytic, Lbus=12 μH.  
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airflow, the DC-DC converter will tolerate brief full current outputs if the  
total RMS current over time does not exceed the Derating curve. All Derating curves are presented at sea level altitude. Be aware of reduced power dissipation with increasing density altitude.  
(4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fixed conditions, Tpcboard=+25 °C, full output load, natural air convection.  
(5) The On/Off Control is normally controlled by a switch, relay or open collector or open drain transistor. But it may also be driven with external logic or by applying appropriate external voltages which are  
referenced to Input Common.  
(6) Short circuit shutdown begins when the output voltage degrades approximately 2ꢀ from the selected setting.  
(7) The output is not intended to sink appreciable reverse current. This may damage the outputs.  
(8) Output noise may be further reduced by adding an external filter. See I/O Filtering and Noise Reduction.  
(9) All models are fully operational and meet published specifications, including “cold start” at –40 °C. Maximum power requires that the package temperature of all on-board components must never exceed  
+128°C.  
(10) Regulation specifications describe the deviation as the line input voltage or output load current is varied from a nominal midpoint value to either extreme.  
(11) The converter is normally specified with the Input/Output filtering listed in Note 1. Higher capacitive load will reduce noise but at the expense of delayed settling time, extended turn-on time and slower tran-  
sient response. Use only as much output filtering as needed and no more. Thoroughly test your system under full load with all components installed. Low ESR capacitors with high capacitance may degrade  
dynamic performance.  
(12) “Hiccup” overcurrent operation repeatedly attempts to restart the converter with a brief, full-current output. If the overcurrent condition still exists, the restart current will be removed and then tried again.  
This short current repeating pulse prevents overheating and damaging the converter. Output current limit and short circuit protection is non-latching. Once the fault is removed, the converter immediately  
recovers normal operation.  
(13) Do not exceed maximum power specifications when adjusting the output trim.  
(14) At zero output current, the output may contain low frequency components which exceed the ripple specification. The output may be operated indefinitely with no load.  
(15) Input Fusing: To ensure reverse input protection, always connect an external input fast-blow fuse in series with the +Vin input.  
(16) Output accuracy is dependent on user-supplied trim resistors. To achieve high accuracy, use 1ꢀ or better tolerance metal-film resistors.  
(17.) Always connect the sense pins. If they are not connected to a remote load, wire each sense pin to its respective voltage output at the converter pins.  
www.murata-ps.com/support  
MDC_HPQ-3.3/50-D48 Series.B01 Page 5 of 11  
HPQ-3.3/50-D48 Series  
Isolated High Power Quarter Brick DC-DC Converters  
TYPICAL PERFORMANCE DATA  
Efficiency vs Line Voltage and Load Current @ +25°C  
Maximum Current Temperature Derating  
(Vin=48V, no baseplate, longitudinal air flow)  
95  
90  
85  
80  
75  
70  
65  
24  
22  
20  
18  
16  
14  
12  
10  
8
50  
45  
40  
V
V
V
IN = 75 V  
IN = 48 V  
IN = 36 V  
35  
30  
25  
20  
15  
10  
100 LFM  
200 LFM  
300 LFM  
400 LFM  
Power Dissipation  
IN = 48 V  
6
V
4
2
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
Load Current (Amps)  
30  
40  
50  
60  
70  
80  
Ambient Temperature (°C)  
Maximum Current Temperature Derating  
(Vin=48V, with baseplate, longitudinal air flow)  
60  
50  
40  
30  
20  
10  
0
100 LFM  
200 LFM  
300 LFM  
400 LFM  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature (°C)  
www.murata-ps.com/support  
MDC_HPQ-3.3/50-D48 Series.B01 Page 6 of 11  
HPQ-3.3/50-D48 Series  
Isolated High Power Quarter Brick DC-DC Converters  
TYPICAL PERFORMANCE DATA  
Transient Response  
Transient Response (25ꢀ Load Step)  
Enable Start-up  
Transient Response (50ꢀ Load Step)  
Enable Start-up (Vin=48V Iout=50A)  
Enable Start-up (Vin=48V Iout=0A)  
Ripple and Noise (1uF Ceramic plus 10uF Tantalum)  
Ripple Waveform (Vin=48V Iout=50A)  
Ripple Waveform (Vin=48V Iout=0A)  
www.murata-ps.com/support  
MDC_HPQ-3.3/50-D48 Series.B01 Page 7 of 11  
HPQ-3.3/50-D48 Series  
Isolated High Power Quarter Brick DC-DC Converters  
MECHANICAL SPECIFICATIONS  
1.860 (47.2)  
A
Dimensions are in inches (mm) shown for ref. only.  
Third Angle Projection  
1.00  
1.45  
(25.4)  
(36.8)  
Screw length  
must not  
go through  
baseplate.  
Tolerances (unless otherwise specified):  
.XX 0.02 (0.5)  
.XXX 0.010 (0.25)  
Angles 2ꢂ  
Components are shown for reference only.  
BASEPLATE  
#M3-THREAD X 0.15 DEEP  
TYPICAL (4) PLACES  
Optional baseplate  
0.50 (12.7)  
With Baseplate  
0.40 (10.2)  
Without Baseplate  
0.015 (0.4)  
min. clearance  
between highest  
component and  
pin shoulders  
0.18  
(4.6)  
PINS 1-3, 5-7: 0.040 0.001 (1.016 0.025)  
PINS 4 & 8: 0.060 0.001 (1.52 0.025)  
Component locations  
are typical and may  
DOSA-Compliant I/O Connections (pin side view)  
Pin  
1
Function P32  
Pin  
5
Function P32  
–Sense  
Trim  
vary between models.  
2.30 (58.4)  
2.00 (50.8)  
A
+Vin  
Remote On/Off Control  
–Vin  
A
2
6
3
7
+Sense  
+Vout  
4
–Vout  
8
Important! Always connect the sense pins. If they are not con-  
nected to a remote load, wire each sense pin to its respective  
voltage output at the converter pins.  
3
2
1
4
5
6
7
8
0.600 (15.2)  
4 EQ. SP.  
@ 0.150 (3.8)  
1.30  
(33.0)  
Standard pin length is shown. Please refer to the part number  
structure for alternate pin lengths.  
Optional mounting  
holes, 4 places  
2.15 (54.6)  
BOTTOM VIEW  
www.murata-ps.com/support  
MDC_HPQ-3.3/50-D48 Series.B01 Page 8 of 11  
HPQ-3.3/50-D48 Series  
Isolated High Power Quarter Brick DC-DC Converters  
Start-Up Threshold and Undervoltage Shutdown  
TECHNICAL NOTES  
Under normal start-up conditions, these converters will not begin to regulate  
properly until the ramping input voltage exceeds the Start-Up Threshold. Once  
operating, devices will turn off when the applied voltage drops below the Und-  
ervoltage Shutdown point. Devices will remain off as long as the undervoltage  
condition continues. Units will automatically re-start when the applied voltage  
is brought back above the Start-Up Threshold. The hysteresis built into this  
function avoids an indeterminate on/off condition at a single input voltage. See  
Performance/Functional Specifications table for actual limits.  
Removal of Soldered Converters from Printed Circuit Boards  
Should removal of the converter from its soldered connection be needed,  
thoroughly de-solder the pins using solder wicks or de-soldering tools. At no  
time should any prying or leverage be used to remove converters that have not  
been properly de-soldered first.  
Input Source Impedance  
These converters must be driven from a low ac-impedance input source. The  
DC-DC’s performance and stability can be compromised by the use of highly  
inductive source impedances. The input circuit shown in Figure 2 is a practical  
solution that can be used to minimize the effects of inductance in the input  
traces. For optimum performance, components should be mounted close to the  
DC-DC converter.  
Start-Up Time  
The VIN to VOUT Start-Up Time is the interval between the point at which a  
ramping input voltage crosses the Start-Up Threshold voltage and the point at  
which the fully loaded output voltage enters and remains within its specified  
regulation band. Actual measured times will vary with input source imped-  
ance, external input capacitance, and the slew rate and final value of the input  
voltage as it appears to the converter. The On/Off to VOUT start-up time assumes  
that the converter is turned off via the Remote On/Off Control with the nominal  
input voltage already applied.  
I/O Filtering, Input Ripple Current, and Output Noise  
All models in this Series are tested/specified for input ripple current (also called  
input reflected ripple current) and output noise using the circuits and layout  
shown in Figures 2 and 3. External input capacitors (CIN in Figure 2) serve  
primarily as energy-storage elements.  
On/Off Control  
The primary-side, Remote On/Off Control function can be specified to operate  
with either positive or negative polarity. Positive-polarity devices ("P" suffix)  
are enabled when the on/off pin is left open or is pulled high. Positive-polarity  
devices are disabled when the on/off pin is pulled low (with respect to –Input).  
Negative-polarity devices are off when the on/off pin is high and on when the  
on/off pin is pulled low. See Figure 4.  
They should be selected for bulk capacitance (at appropriate frequencies),  
low ESR, and high rms-ripple-current ratings. The switching nature of DC-DC  
converters requires that dc voltage sources have low ac impedance as highly  
inductive source impedance can affect system stability. In Figure 2, CBUS and  
LBUS simulate a typical dc voltage bus. Your specific system configuration may  
necessitate additional considerations.  
Dynamic control of the remote on/off function is best accomplished with a me-  
chanical relay or an open-collector/open-drain drive circuit (optically isolated if  
appropriate). The drive circuit should be able to sink appropriate current (see  
Performance Specifications) when activated and withstand appropriate voltage  
when deactivated.  
In critical applications, output ripple and noise (also referred to as periodic and  
random deviations or PARD) may be reduced by adding filter elements such  
as multiple external capacitors. Be sure to calculate component temperature  
rise from reflected AC current dissipated inside capacitor ESR.All external  
capacitors should have appropriate voltage ratings and be located as close to  
the converter as possible. Temperature variations for all relevant parameters  
should be taken into consideration.  
The most effective combination of external I/O capacitors will be a function  
of line voltage and source impedance, as well as particular load and layout  
conditions.  
TO  
CURRENT  
PROBE  
OSCILLOSCOPE  
7
+SENSE  
1
3
8
+VIN  
–VIN  
+VOUT  
L
BUS  
+
RLOAD  
SCOPE  
C1  
C2  
VIN  
C
BUS  
CIN  
4
5
–VOUT  
–SENSE  
See specs for component values.  
C1 = 1μF  
Figure 2. Measuring Input Ripple Current  
C2 = 10μF TANTALUM  
LOAD 2-3 INCHES (51-76mm) FROM MODULE  
Figure 3. Measuring Output Ripple/Noise (PARD)  
www.murata-ps.com/support  
MDC_HPQ-3.3/50-D48 Series.B01 Page 9 of 11  
HPQ-3.3/50-D48 Series  
Isolated High Power Quarter Brick DC-DC Converters  
Sense Input  
temperature (See Performance Specifications), a precision temperature sensor  
will power down the unit. When the internal temperature decreases below the  
threshold of the temperature sensor, the unit will self start.  
Note: The sense and VOUT lines are internally connected through low-value re-  
sistors. Nevertheless, if sense is not used for remote regulation, the user must  
connect + sense to + VOUT and -sense to -VOUT at the converter pins. Sense is  
intended to correct small output accuracy errors caused by the resistive ohmic  
drop in output wiring as output current increases. This output drop (the differ-  
ence between Sense and VOUT when measured at the converter) should not be  
allowed to exceed 0.5V.  
Output Overvoltage Protection  
The output voltage is monitored for an overvoltage condition via magnetic coupling  
to the primary side. If the output voltage rises to a fault condition, which could be  
damaging to the load circuitry (see Performance Specifications), the sensing cir-  
cuitry will power down the PWM controller causing the output voltage to decrease.  
Following a time-out period the PWM will restart, causing the output voltage to  
ramp to its appropriate value. If the fault condition persists, and the output volt-  
ages again climb to excessive levels, the overvoltage circuitry will initiate another  
shutdown cycle. This on/off cycling is referred to as “hiccup” mode.  
Sense is connected at the load and corrects for resistive errors only. Be careful  
where it is connected. Any long, distributed wiring and/or significant inductance  
introduced into the Sense control loop can adversely affect overall system stabil-  
ity. If in doubt, test the application, and observe the DC-DC’s output transient  
response during step loads. There should be no appreciable ringing or oscilla-  
tion. You may also adjust the output trim slightly to compensate for voltage loss  
in any external filter elements. Do not exceed maximum power ratings.  
Input Reverse-Polarity Protection  
If the input-voltage polarity is accidentally reversed, an internal diode will be-  
come forward biased and likely draw excessive current from the power source.  
If the source is not current limited or the circuit appropriately fused, it could  
cause permanent damage to the converter.  
Current Limiting  
When power demands from the output falls within the current limit inception  
range for the rated output current, the DC-DC converter will go into a current  
limiting mode. In this condition the output voltage will decrease proportionately  
with increases in output current, thereby maintaining a somewhat constant power  
dissipation. This is commonly referred to as power limiting. Current limit inception  
is defined as the point where the full-power output voltage falls below the specified  
tolerance. If the load current being drawn from the converter is significant enough,  
the unit will go into a short circuit condition. See “Short Circuit Condition.”  
Input Fusing  
Certain applications and/or safety agencies may require the installation of  
fuses at the inputs of power conversion components. Fuses should also be  
used if the possibility of a sustained, non-current-limited, input-voltage polarity  
reversal exists. For these converters, fast-blow fuses are recommended with  
values no greater than twice the maximum input current.  
Short Circuit Condition  
Trimming Output Voltage  
When a converter is in current limit mode the output voltages will drop as the  
output current demand increases. If the output voltage drops too low, the mag-  
netically coupled voltage used to develop primary side voltages will also drop,  
thereby shutting down the PWM controller. Following the specified time-out  
period, the PWM will restart, causing the output voltages to begin ramping to their  
appropriate values. If the short-circuit condition persists, another shutdown  
cycle will be initiated. This on/off cycling is referred to as “hiccup” mode. The  
hiccup cycling reduces the average output current, thereby preventing internal  
temperatures from rising to excessive levels. This converter is capable of  
enduring an indefinite short circuit output condition.  
These converters have a trim capability that enables users to adjust the output  
voltage over a limited range (refer to the trim equations). Adjustments to the out-  
put voltage can be accomplished with a single fixed resistor as shown in Figures  
5 and 6. A single fixed resistor can increase or decrease the output voltage  
depending on its connection. Resistors should be located close to the converter  
and have TCR’s less than 100ppm/°C to minimize sensitivity to changes in  
temperature. If the trim function is not used, leave the trim pin open.  
On standard units, a single resistor connected from the Trim pin to the +Sense  
will increase the output voltage. A resistor connected from the Trim Pin to the  
–Sense will decrease the output voltage.  
Thermal Shutdown  
Trim adjustments greater than the specified trim range can have an adverse  
affect on the converter’s performance and are not recommended. Excessive  
voltage differences between VOUT and Sense, in conjunction with trim adjust-  
ment of the output voltage, can cause the overvoltage protection circuitry to  
activate (see Performance Specifications for overvoltage limits).  
These converters are equipped with thermal-shutdown circuitry. If the internal  
temperature of the DC-DC converter rises above the designed operating  
EQUIVALENT CIRCUIT FOR  
POSITIVE AND NEGATIVE  
LOGIC MODELS  
+Vcc  
+VIN  
1
2
Temperature/power derating is based on maximum output current and voltage  
at the converter’s output pins. Use of the trim and sense functions can cause  
output voltages to increase, thereby increasing output power beyond the  
converter’s specified rating, or cause output voltages to climb into the output  
overvoltage region. Therefore:  
ON/OFF  
CONTROL  
CONTROL  
(VOUT at pins) x (IOUT) rated output power  
REF  
3
–VIN  
COMMON  
The Trim pin is a relatively high impedance node that can be susceptible to  
noise pickup when connected to long conductors in noisy environments.  
Figure 4. Driving the Remote On/Off Control Pin  
www.murata-ps.com/support  
MDC_HPQ-3.3/50-D48 Series.B01 Page 10 of 11  
HPQ-3.3/50-D48 Series  
Isolated High Power Quarter Brick DC-DC Converters  
+VOUT  
+VIN  
+VOUT  
+SENSE  
TRIM  
+VIN  
+SENSE  
ON/OFF  
CONTROL  
ON/OFF  
CONTROL  
TRIM  
–SENSE  
–VOUT  
LOAD  
LOAD  
RTRIM DOWN  
RTRIM UP  
–SENSE  
–VOUT  
–VIN  
–VIN  
Figure 6. Trim Connections To Decrease Output Voltages Using Fixed Resistors  
Trim Down  
Figure 5. Trim Connections To Increase Output Voltages Using Fixed Resistors  
Trim Up  
HPQ-3.3/50-D48  
16.863(1+)  
5.11  
5.11  
10.22  
10.22  
RTUP (k7) =  
RTDOWN (k7) =  
1.225x∆  
where is the absolute value of  
( 3.3 - VOUT  
)
3.3  
(is always positive)  
Soldering Guidelines  
Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceeding these specifica-  
tions may cause damage to the product. Your production environment may differ; therefore please thoroughly review these guidelines with your process engineers.  
Wave Solder Operations for through-hole mounted products (THMT)  
For Sn/Ag/Cu based solders:  
For Sn/Pb based solders:  
Maximum Preheat Temperature 115° C.  
Maximum Preheat Temperature 105° C.  
Maximum Pot Temperature  
Maximum Solder Dwell Time  
270° C.  
Maximum Pot Temperature  
250° C.  
7 seconds Maximum Solder Dwell Time  
6 seconds  
NOTICE—Please use only this customer data sheet as product documentation  
when laying out your printed circuit boards and applying this product into your  
application. Do NOT use other materials as official documentation such as adver-  
tisements, product announcements, or website graphics.  
The pinout (Pxx) and case (Cxx) designations (typically P65 or C59) refer to  
a generic family of closely related information. It may not be a single pinout  
or unique case outline. Please be aware of small details (such as Sense pins,  
Power Good pins, etc.) or slightly different dimensions (baseplates, heat  
sinks, etc.) which may affect your application and PC board layouts. Study the  
Mechanical Outline drawings, Input/Output Connection table and all footnotes  
very carefully. Please contact Murata Power Solutions if you have any ques-  
tions.  
We strive to have all technical data in this customer data sheet highly accurate  
and complete. This customer data sheet is revision-controlled and dated. The  
latest customer data sheet revision is normally on our website (www.murata-  
ps.com) for products which are fully released to Manufacturing. Please be  
especially careful using any data sheets labeled “Preliminary” since data may  
change without notice.  
This product is subject to the following operating requirements  
and the Life and Safety Critical Application Sales Policy:  
Refer to: http://www.murata-ps.com/requirements/  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
ISO 9001 and 14001 REGISTERED  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
notice.  
© 2013 Murata Power Solutions, Inc.  
www.murata-ps.com/support  
MDC_HPQ-3.3/50-D48 Series.B01 Page 11 of 11  

相关型号:

HPQ-3.3/50-D48PL2C

Isolated High Power Quarter Brick DC/DC Converters
MURATA

HPQ-3.3/50-D48PL2Y

Isolated High Power Quarter Brick DC/DC Converters
MURATA

HPQ-3.3/50-D48PY

Isolated High Power Quarter Brick DC/DC Converters
MURATA

HPQ-50-D48N-C

Isolated High Power Quarter Brick DC/DC Converters
MURATA

HPQ-50-D48N-Y

Isolated High Power Quarter Brick DC/DC Converters
MURATA

HPQ-50-D48NB-C

Isolated High Power Quarter Brick DC/DC Converters
MURATA

HPQ-50-D48NB-Y

Isolated High Power Quarter Brick DC/DC Converters
MURATA

HPQ-50-D48NBH-C

Isolated High Power Quarter Brick DC/DC Converters
MURATA

HPQ-50-D48NBH-Y

Isolated High Power Quarter Brick DC/DC Converters
MURATA

HPQ-50-D48NH-C

Isolated High Power Quarter Brick DC/DC Converters
MURATA

HPQ-50-D48NH-Y

Isolated High Power Quarter Brick DC/DC Converters
MURATA

HPQ-50-D48P-C

Isolated High Power Quarter Brick DC/DC Converters
MURATA