KMP_7625XEN [MURATA]

EN Approved MAX250/251/253 Compatible Converter Transformers; EN认证MAX250 /二百五十三分之二百五十一兼容的转换器变压器
KMP_7625XEN
型号: KMP_7625XEN
厂家: muRata    muRata
描述:

EN Approved MAX250/251/253 Compatible Converter Transformers
EN认证MAX250 /二百五十三分之二百五十一兼容的转换器变压器

变压器 转换器
文件: 总4页 (文件大小:145K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
76250ENC, 76253/XXENC  
EN Approved MAX250/251/253 Compatible Converter Transformers  
SELECTION GUIDE  
Output  
Voltage  
Max. Output  
Current  
Isolation  
Voltage  
Input Voltage  
Turns  
Ratio  
Order Code  
V
-
V
-
mA  
-
VDC  
76250ENC  
76253/35ENC  
76253/55ENC  
6000  
6000  
6000  
1CT:1  
1:√5  
3.3  
5.0  
5.0  
5.0  
100  
200  
1:1.33  
76250ENC CHARACTERISTICS  
Parameter  
FEATURES  
RoHS compliant  
Conditions  
Min.  
1.0  
Typ.  
2.0  
35  
Max.  
Units  
mH  
μH  
Primary Inductance, LP (1&5)  
Leakage Inductance, LL (1&5)2  
10kHz, 100mV  
100kHz, 100mV  
2.5  
40  
Maxim MAX250/MAX251/MAX253  
compatible  
Interwinding Capacitance, CWW (1&2) 100kHz, 100mV  
1.5  
1.0  
3.0  
2.0  
pF  
D.C. Resistance, RDC (1&5)  
Volt-time Product, ET (1&5)  
<0.1VDC  
Ω
Vμs  
BS EN 60950 approved  
Isolation to 6kVDC  
50  
76253/35ENC CHARACTERISTICS  
Parameter  
Toroidal construction  
Conditions  
Min.  
140  
700  
Typ.  
200  
Max.  
Units  
μH  
Industry-standard pinout  
UL 94 V-0 package materials  
Fully encapsulated  
Primary Inductance, LP (1&5)  
Secondary Inductance, LS (2&6)  
Leakage Inductance, LL (1&5)2  
100kHz, 250mV  
100kHz, 250mV  
100kHz, 250mV  
1000  
7.0  
μH  
5.0  
2.7  
0.4  
35  
μH  
Interwinding Capacitance, CWW (1&2) 100kHz, 250mV  
3.5  
pF  
Compatible with RoHS soldering systems  
D.C. Resistance, RDC (1&5)  
Volt-time Product, ET (1&5)  
<0.1VDC  
0.8  
Ω
Vμs  
Backward compatible with  
Sn/Pb soldering systems  
25  
76253/55ENC CHARACTERISTICS  
Parameter  
Conditions  
Min.  
80  
Typ.  
Max.  
150  
267  
10.0  
3.5  
Units  
μH  
DESCRIPTION  
Primary Inductance, LP (1&5)  
Secondary Inductance, LS (2&6)  
Leakage Inductance, LL (1&5)2  
100kHz, 250mV  
100kHz, 250mV  
100kHz, 250mV  
The 76250ENC converter transformer is  
specifically designed for use with Maxim  
chipsets to provide isolated RS232 interfaces. A  
carefully controlled turns ratio ensures consistent  
performance whilst a toroidal construction  
minimises EMI.  
142  
μH  
7.0  
2.7  
0.5  
40  
μH  
Interwinding Capacitance, CWW (1&2) 100kHz, 250mV  
pF  
D.C. Resistance, RDC (1&5)  
Volt-time Product, ET (1&5)  
<0.1VDC  
0.9  
Ω
Vμs  
30  
The 76253/XXENC converter transformers are  
specifically designed for use with the MAX253  
chip set to provide isolated power supplies. The  
5V version can supply 1W and the 3.3V version  
can supply 500mW. A centre tapped secondary  
winding allows for full bridge, half bridge or  
voltage doubling.  
ABSOLUTE MAXIMUM RATINGS  
0°C to 70°C  
Operating free air temperature range 76250EN  
Operating free air temperature range 76253/XXEN  
Storage temperature range  
-40°C to 85°C  
-50°C to 125°C  
300°C  
Lead temperature 1.5mm from case for 10 seconds  
Peak current, IPK 76250EN  
300mA  
The devices are fully approved to BS EN 60950 for  
use in telecoms applications.  
400mA  
Peak current, IPK 76253/XXEN  
6000VDC  
Isolation voltage (flash tested for 1 second)  
SOLDERING INFORMATION3  
Peak wave solder temperature  
Pin finish  
300˚C for 10 seconds  
Matte tin  
All specifications typical at TA=25°C  
1
2
3
Refer to mechanical dimensions for pin locations shown in brackets.  
With pins 2 & 6 short circuited.  
For further information, please visit www.murata-ps.com/rohs  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com  
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232  
KMP_7625XENC_B03 Page 1 of 4  
76250ENC, 76253/XXENC  
EN Approved MAX250/251/253 Compatible Converter Transformers  
TYPICAL CHARACTERISTICS (VOLTAGE CURVES)  
VOLTAGE CURVES  
76253/35ENC  
76253/55ENC  
10  
10  
8
8
6
4
2
0
6
4
2
0
0
20  
40  
60  
80  
100  
100  
100  
0
100  
200  
300  
400  
400  
100  
Output Current (mA)  
Output Current (mA)  
EFFICIENCY CURVES  
76253/35ENC  
76253/55ENC  
100  
80  
60  
40  
20  
0
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
0
100  
200  
300  
Output Current (mA)  
Output Current (mA)  
VOLTAGE DEVIATION  
76253/35ENC  
76253/55ENC  
110  
105  
110  
105  
100  
95  
100  
95  
90  
90  
-50 -25  
0
25  
50  
75  
-50 -25  
0
25  
50  
75  
Temperature (ºC)  
Temperature (ºC)  
All curves are derived from testing with the Maxim MAX235 IC using the circuit shown in application note MPAN-03 (download at http://www.murata-ps.com/data/apnotes/mpan-03.pdf).  
www.murata-ps.com  
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232  
KMP_7625XENC_B03 Page 2 of 4  
76250ENC, 76253/XXENC  
EN Approved MAX250/251/253 Compatible Converter Transformers  
PACKAGE SPECIFICATIONS  
MECHANICAL DIMENSIONS  
15.00 (0.59)  
1
3
5
2
12.00  
2.54  
12.50  
15.00  
(0.59)  
(0.472)  
(0.1)  
(0.492)  
4*  
6
76250ENC  
XYYWW  
7.50  
(0.295)  
4.10  
(0.161)  
Ø0.56 0.05  
(Ø0.022 0.002)  
10.16 (0.4)  
2.42 (0.095)  
Pin Connections 76250EN (Top View)  
Primary Secondary  
Pin Connections 76253/XXEN (Top View)  
Primary  
Secondary  
1
3
5
1
3
5
2
6
2
4
6
* 76250EN Pin not fitted.  
Unless otherwise stated all dimensions in mm (inches) 0.25mm ( 0.01).  
All pins on a 2.54mm (0.1") pitch and within 0.25mm (0.01") of true position.  
TUBE DIMENSIONS  
RECOMMENDED FOOTPRINT DETAILS  
ꢃꢂꢊꢃœꢃꢂꢍꢇꢄꢅꢃꢂꢃꢀꢁœꢃꢂꢃꢃꢊꢈꢄꢄꢄ  
2.54 (0.100)  
3ꢃꢂꢉꢇꢄꢅꢃꢂꢃꢌꢃꢈ  
ꢍꢉꢂꢃꢃꢄ  
ꢅꢃꢂꢊꢊꢆꢈ  
ꢋꢂꢃꢃꢄ  
ꢅꢃꢂꢌꢍꢇꢈ  
ꢉꢂꢃꢃ  
ꢅꢃꢂꢀꢉꢊꢈ  
x6 HOLES*  
Ø1.00+0.15-0.00 (Ø0.039+0.006-0.000)  
ꢀꢁꢂꢃꢃꢄꢅꢃꢂꢆꢁꢇꢈ  
Tube length: 480 2.00mm (18.90 0.079"). Tube quantity: 30  
Tube material: Antistatic coated clear pvc.  
Holes may be omitted for variants with fewer than 6 pins.  
Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01).  
All pins on a 2.54 (0.1) pitch and within 0.25 (0.01) of true position.  
Unless otherwise stated all dimensions in mm (inches) -0.00 +0.50 (-0.00 +0.020).  
www.murata-ps.com  
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232  
KMP_7625XENC_B03 Page 3 of 4  
76250ENC, 76253/XXENC  
EN Approved MAX250/251/253 Compatible Converter Transformers  
TECHNICAL NOTES  
ISOLATION VOLTAGE  
REPEATED HIGH-VOLTAGE ISOLATION TESTING  
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand  
Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test  
voltage, applied for a specified time, across a component designed to provide electrical  
isolation, to verify the integrity of that isolation.  
It is well known that repeated high-voltage isolation testing of a barrier component can  
actually degrade isolation capability, to a lesser or greater degree depending on materi-  
als, construction and environment. We therefore strongly advise against repeated high  
voltage isolation testing, but if it is absolutely required, that the voltage be reduced by  
20% from the specified test voltage.  
All products in this series are 100% production tested at their stated isolation voltage.  
This series is recognised by the British Standards Institution to a working voltage of  
300Vrms for Reinforced Insulation systems.  
USA:  
Mansfield (MA), Tel: (508) 339 3000, email: sales@murata-ps.com  
Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com  
UK:  
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com  
Murata Power Solutions, Inc.  
France:  
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356  
www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED  
Germany: München, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com  
Japan:  
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com  
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com  
China:  
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com  
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com  
notice.  
© 2008 Murata Power Solutions, Inc.  
www.murata-ps.com  
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232  
KMP_7625XENC_B03 Page 4 of 4  

相关型号:

KMP_766

Pulse Transformers
MURATA

KMP_782485C

ADM2485 Compatible Converter Transformers
MURATA

KMP_78250

MAX250 Compatible Converter Transformers
MURATA

KMP_786

General Purpose Pulse Transformers
MURATA

KMP_8200C

Miniature Surface Mount Power Inductors
MURATA

KMP_8400

Miniature Surface Mount Power Inductors
MURATA

KMP_DA100

Transformers for Digital Audio Data Transmission
MURATA

KMQE10013M-B318

Flash Memory Drive, 200MBps, CMOS, PBGA221, BGA-221
SAMSUNG

KMR

Microminiature Tact Switch for SMT
ITT

KMR2

Microminiature SMT Top Actuated
CK-COMPONENTS

KMR211G

Microminiature Tact Switch for SMT
ITT

KMR211GLFS

Microminiature SMT Top Actuated
CK-COMPONENTS