LSN-1.25/10-D3B-C [MURATA]

DC-DC Regulated Power Supply Module, 1 Output, 12.5W, Hybrid, ROHS COMPLIANT, SIP-9/11;
LSN-1.25/10-D3B-C
型号: LSN-1.25/10-D3B-C
厂家: muRata    muRata
描述:

DC-DC Regulated Power Supply Module, 1 Output, 12.5W, Hybrid, ROHS COMPLIANT, SIP-9/11

文件: 总14页 (文件大小:343K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
LSN-10A D3 Models  
s
Single Output, Non-Isolated, 3.3VIN, 1-2.5VOUT, 10A, DC/DC's in SIP Packages  
NOT RECOMMENDED  
FOR NEW DESIGNS  
input range) and deliver 1V, 1.2V, 1.25V, 1.5V, 1.8V, 2V or 2.5V out-  
puts at 10 Amps. LSN D3 SIP’s are designed to take on-board 3.3V  
power and convert it, with the highest efficiency in the smallest space,  
to any lower voltage required by today’s current-hungry DSP’s, ASIC’s  
and CPLD’s.  
Typical Units  
Features  
The miniature size of LSN D3's makes them ideal for true point-of-use power  
processing. Vertical-mount packages occupy a mere 0.7 square inches (440 sq.  
mm), and they are available in industry-standard and Tyco-compatible pinout.  
Horizontal-mount packages ("H" suffix) are only 0.34 inches (8.6mm) high.  
The LSN's best-in-class power density is achieved with a fully synchronous,  
fixed-frequency (300kHz), buck topology that also delivers: high efficiency (94% for  
2.5VOUT models), low noise (10mVp-p typ.), tight line/load regulation ( 0.1%/ 0.25%  
max.), quick step response (100μsec), stable no-load operation, and no output  
reverse conduction.  
The fully functional LSN’s feature output overcurrent detection, continuous short-  
circuit protection, an output-voltage trim function, a remote on/off control pin  
(pull high to disable), thermal shutdown, and a sense pin. High efficiency enables the  
LSN D3's to deliver rated output currents of 10 Amps at ambient temperatures to  
+71°C with no air flow (natural convection).  
Industry-standard SIP pinout  
Shorter (2.0" vs. 2.5") package length  
3.0-3.6V input range  
1/1.2/1.25/1.5/1.8/2/2.5V outputs @ 10A  
Non-isolated, fully synchronous,  
300kHz, buck topology  
Outstanding performance:  
1ꢀ setpoint accuracy  
Efficiencies to 94ꢀ @ 10 Amps  
Noise as low as 10mVp-p  
Stable no-load operation  
Trimmable output voltage  
If your low-voltage, high-current requirements have made the use of inefficient  
linear regulators impractical, take a look at one of DATELs easy-to-use, low-cost  
LSN SIP’s. All devices are UL/IEC/EN60950 certified and EMC compliant. UL, CB,  
HALT and EMC reports are available upon request.  
Remote on/off and sense pins  
Thermal Shutdown  
No derating to +71°C, natural convection  
UL/IEC/EN60950 certified  
EMC compliant  
+OUTPUT  
(1,2,4)  
+INPUT  
(7,8)  
10.5Ω  
+SENSE  
330μF  
44μF  
47.1μF  
470μF  
(3)  
COMMON  
(5)  
COMMON  
(6)  
CURRENT  
SENSE  
VOLTAGE  
BOOST  
VCC  
PWM  
ON/OFF  
CONTROL  
(11)  
REFERENCE &  
ERROR AMP  
CONTROLLER  
TRIM  
(10)  
Typical topology is shown  
Figure 1. Simplified Schematic  
For devices with the sense-pin removed ("B" suffix),  
the feedback path is through the +Output pin and not  
the +Sense pin.  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com  
email: sales@murata-ps.com  
16 Dec 2009 MDC_LSN10A-D3.B03 Page 1 of 14  
LSN-10A D3 Models  
Single Output, Non-Isolated, 3.3VIN, 1-2.5VOUT, 10A, DC/DC's in SIP Packages  
Performance Specifications and Ordering Guide  
Output  
Input  
Efficiency  
Full Load  
Package  
(Case,  
Pinout)  
½ Load  
Typ.  
R/N (mVp-p) ➁  
Regulation (Max.) ➂  
VIN Nom.  
(Volts)  
Range  
(Volts)  
IIN ➃  
VOUT  
(Volts)  
IOUT  
(Amps)  
Root Model ➄  
Typ.  
Max.  
Line  
0.1ꢀ  
Load  
(mA/A)  
Min.  
Typ.  
LSN-1/10-D3  
1
1.2  
1.25  
1.5  
1.8  
2
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
35  
35  
35  
35  
35  
35  
35  
0.25ꢀ  
0.25ꢀ  
0.25ꢀ  
0.25ꢀ  
0.25ꢀ  
0.25ꢀ  
0.25ꢀ  
3.3  
3.3  
3.3  
3.3  
3.3  
3.3  
3.3  
3.0-3.6  
3.0-3.6  
3.0-3.6  
3.0-3.6  
3.0-3.6  
3.0-3.6  
3.0-3.6  
70/3.73  
70/4.42  
60/4.30  
70/5.47  
70/6.33  
70/6.96  
70/8.50  
83.5ꢀ  
85ꢀ  
86.5ꢀ  
88ꢀ  
90.5ꢀ  
91ꢀ  
B7/B7x, P59  
B7/B7x, P59  
B7/B7x, P59  
B7/B7x, P59  
B7/B7x, P59  
B7/B7x, P59  
B7/B7x, P59  
LSN-1.2/10-D3  
LSN-1.25/10-D3  
LSN-1.5/10-D3  
LSN-1.8/10-D3  
LSN-2/10-D3  
0.1ꢀ  
0.1ꢀ  
0.1ꢀ  
0.1ꢀ  
0.1ꢀ  
0.1ꢀ  
85ꢀ  
88ꢀ  
91ꢀ  
87.5ꢀ  
89ꢀ  
90ꢀ  
92.2ꢀ  
93.5ꢀ  
94ꢀ  
91.5ꢀ  
92.5ꢀ  
94ꢀ  
89.5ꢀ  
91ꢀ  
LSN-2.5/10-D3  
2.5  
95.5ꢀ  
Typical at TA = +25°C under nominal line voltage and full-load conditions, unless otherwise  
noted. All models are tested and specified with external 22μF input and output capacitors.  
These capacitors are necessary to accommodate our test equipment and may not be required  
to achieve specified performance in your applications. See I/O Filtering and Noise Reduction.  
Ripple/Noise (R/N) is tested/specified over a 20MHz bandwidth and may be reduced with  
external filtering. See I/O Filtering and Noise Reduction for details.  
These devices have no minimum-load requirements and will regulate under no-load conditions.  
Regulation specifications describe the output-voltage deviation as the line voltage or load is  
varied from its nominal/midpoint value to either extreme.  
Nominal line voltage, no-load/full-load conditions.  
These are not complete model numbers. Please refer to the Part Number Structure for  
additional options when ordering.  
M E C H A N I C A L S P E C I F I C A T I O N S  
P A R T N U M B E R S T R U C T U R E  
0.34  
(8.6)  
2.00  
(50.8)  
0.20  
(5.1)  
L SN -  
1.8 / 10- D3 B H J  
- C  
Output  
Configuration:  
L = Unipolar  
RoHS-6 compliant  
0.17  
0.50  
(4.3)  
(12.7)  
1
2
3
4
5
6 7 8 9 10 11  
J Suffix:  
Low Voltage  
Reversed Pin  
Vertical Mount  
Non-Isolated SIP  
0.110  
(2.8)  
0.030 0.001 DIA.  
(0.762 0.025)  
0.05  
(1.3)  
H Suffix:  
Horizontal Mount  
Nominal Output Voltage:  
1, 1.2, 1.25, 1.5, 1.8, 2, or 2.5 Volts  
1.000  
(25.40)  
0.400  
(10.16)  
0.500  
(12.70)  
0.046  
(1.2)  
B Suffix:  
No Remote Sense  
(Pin 3 removed)  
4 EQ. SP. @  
0.100 (2.54)  
5 EQ. SP. @  
0.100 (2.54)  
Maximum Rated Output  
Current in Amps  
Case B7  
Vertical Mounting  
(Standard)  
0.34  
(8.6)  
LAYOUT PATTERN  
TOP VIEW  
Input Voltage Range:  
D3 = 3 to 3.6 Volts  
(3.3V nominal)  
See page 12 for  
Part Number Structure  
and ordering details.  
0.25  
(6.4)  
0.36  
(9.1)  
0.35  
(8.9)  
2.00  
(50.8)  
0.20  
(5.1)  
2.00  
(50.8)  
0.21  
(5.3)  
0.17  
(4.3)  
0.50  
(12.7)  
ISOLATING  
PAD  
0.05  
(1.3)  
0.50  
(12.7)  
6
7 8 9 10 11  
1
2 3 4 5  
1
2
3
4 5  
6
7 8 9 10 11  
0.16  
(4.1)  
0.046  
(1.2)  
0.030 0.001 DIA.  
(0.762 0.025)  
0.030 0.001 DIA.  
(0.762 0.025)  
0.05  
(1.3)  
0.05  
(1.3)  
0.360  
(9.1)  
0.106  
(2.7)  
1.000  
(25.40)  
1.000  
(25.40)  
0.400  
(10.16)  
0.500  
(12.70)  
0.400  
(10.16)  
0.500  
(12.70)  
4 EQ. SP. @  
0.100 (2.54)  
5 EQ. SP. @  
0.100 (2.54)  
4 EQ. SP. @  
0.100 (2.54)  
5 EQ. SP. @  
0.100 (2.54)  
Case B7B  
Reverse Pin  
Vertical Mounting  
Case B7A  
Horizontal Mounting  
0.56  
(14.2)  
0.53  
(13.5)  
LAYOUT PATTERN  
TOP VIEW  
0.36  
(9.1)  
0.306  
(7.8)  
(Tyco/Lineage-compatible)  
0.50  
(12.7)  
0.45  
(11.4)  
Dimensions are in inches (mm shown for ref. only).  
Standard model pin  
lengths are shown.  
LAYOUT PATTERN  
TOP VIEW  
Third Angle Projection  
RECOMMENDED  
COPPER PAD  
ON PCB (0.55 SQ. IN.)  
I/O Connections  
Pin Function P59*  
Pin  
5
Function P59* Pin Function P59*  
Tolerances (unless otherwise specified):  
.XX 0.02 (0.5)  
.XXX 0.010 (0.25)  
Angles 2ꢀ  
1
2
3
4
+Output  
+Output  
+Sense *  
+Output  
Common  
Common  
+Input  
9
No Pin  
VOUT Trim  
6
10  
11  
*
Pin 3 (+Sense) removed  
for "B" suffix models.  
7
On/Off Control  
8
+Input  
Components are shown for reference only.  
www.murata-ps.com  
email: sales@murata-ps.com  
16 Dec 2009 MDC_LSN10A-D3.B03 Page 2 of 14  
LSN-10A D3 Models  
Single Output, Non-Isolated, 3.3VIN, 1-2.5VOUT, 10A, DC/DC's in SIP Packages  
Typical @ TA = +25°C under nominal line voltage and full-load conditions unless noted. ➀  
Performance/Functional Specifications  
Absolute Maximum Ratings  
Input  
Input Voltage Range  
3.0 to 3.6 Volts (3.3V nominal)  
Input Voltage:  
Continuous or transient  
6 Volts  
Input Current:  
Normal Operating Conditions  
Inrush Transient  
Standby/Off Mode  
See Ordering Guide  
0.02A2sec  
3mA  
On/Off Control (Pin 11)  
+VIN  
Input Reverse-Polarity Protection  
Output Overvoltage Protection  
Output Current  
None, install external fuse  
None  
Output Short-Circuit Condition ➁  
70mA average  
Current limited. Devices can  
withstand sustained output short  
circuits without damage.  
Input Reflected Ripple Current ➁  
Input Filter Type  
50mAp-p  
Capacitive (374μF)  
None  
Overvoltage Protection  
Reverse-Polarity Protection  
Undervoltage Shutdown  
Sense Range  
Storage Temperature  
–40 to +125°C  
+300°C  
None, install external fuse  
None  
Lead Temperature (soldering, 10 sec.)  
10ꢀ of VOUT  
These are stress ratings. Exposure of devices to greater than any of these conditions may  
adversely affect long-term reliability. Proper operation under conditions other than those  
listed in the Performance/Functional Specifications Table is not implied.  
On/Off Control ➁ ➂  
On = open (internal pulldown)  
Off = +2.8V to +VIN (<3mA)  
Output  
T E C H N I C A L N O T E S  
VOUT Accuracy (50ꢀ load)  
Minimum Loading ➀  
Maximum Capacitive Load  
VOUT Trim Range ➁  
1ꢀ maximum  
No load  
Return Current Paths  
10,000μF (electrolytic)  
10ꢀ  
The LSN D3 SIP’s are non-isolated DC/DC converters. Their two Common  
pins (pins 5 and 6) are connected to each other internally (see Figure 1). To  
the extent possible (with the intent of minimizing ground loops), input return  
current should be directed through pin 6 (also referred to as –Input or  
Input Return), and output return current should be directed through pin 5  
(also referred to as –Output or Output Return). Any on/off control signals  
applied to pin 11 (On/Off Control) should be referenced to Common  
(specifically pin 6).  
Ripple/Noise (20MHz BW) ➀ ➁ ➃  
Temperature Coefficient  
Total Accuracy  
See Ordering Guide  
0.02ꢀ/°C  
3ꢀ over line/load/temperature  
See Ordering Guide  
Efficiency ➁  
Overcurrent Detection and Short-Circuit Protection: ➁  
Current-Limiting Detection Point  
Short-Circuit Detection Point  
SC Protection Technique  
Short-Circuit Current  
16 (12.5 to 22) Amps  
98ꢀ of VOUT set  
I/O Filtering and Noise Reduction  
Hiccup with auto recovery  
600mA average  
All models in the LSN D3 Series are tested and specified with external 22μF  
input and output capacitors. These capacitors are necessary to accommodate  
our test equipment and may not be required to achieved desired performance  
in your application. The LSN D3's are designed with high-quality, high-  
performance internal I/O caps, and will operate within spec in most applica-  
tions with no additional external components.  
Dynamic Characteristics  
Transient Response (50ꢀ load step) 100μsec to 2ꢀ of final value  
Start-Up Time: ➁  
VIN to VOUT  
On/Off to VOUT  
7msec  
6msec  
Switching Frequency  
300kHz (+40kHz, –50kHz)  
In particular, the LSN D3's input capacitors are specified for low ESR  
and are fully rated to handle the units' input ripple currents. Similarly, the  
internal output capacitors are specified for low ESR and full-range frequency  
response. As shown in the Performance Curves, removal of the external  
output caps has minimal effect on output noise.  
Environmental  
2.1 million hours  
MTBF ➄  
Operating Temperature: (Ambient) –40 to +85°C with Derating  
See Derating Curves  
Thermal Shutdown  
+115°C  
In critical applications, input/output ripple/noise may be further reduced using  
filtering techniques, the simplest being the installation of external I/O caps.  
Physical  
Dimensions  
See Mechanical Specifications  
Pin Dimensions/Material  
0.03" (0.76mm) round copper alloy with  
tin plate over nickel underplate  
External input capacitors serve primarily as energy-storage devices. They  
minimize high-frequency variations in input voltage (usually caused by IR  
drops in conductors leading to the DC/DC) as the switching converter draws  
pulses of current. Input capacitors should be selected for bulk capacitance (at  
appropriate frequencies), low ESR, and high rms-ripple-current ratings. The  
switching nature of modern DC/DC's requires that the dc input voltage  
source have low ac impedance at the frequencies of interest. Highly inductive  
source impedances can greatly affect system stability.Your specific system  
configuration may necessitate additional considerations.  
Weight  
0.3 ounces (8.5g)  
Flamability Rating  
Safety  
UL94V-0  
UL/cUL/IEC/EN 60950-1, CSA-C22.2 No. 234  
All models are tested/specified with external 22μF input/output capacitors.These caps  
accommodate our test equipment and may not be required to achieve specified performance  
in your applications. All models are stable and regulate within spec under no-load conditions.  
See Technical Notes and Performance Curves for details.  
The On/Off Control (pin 11) is designed to be driven with open-collector logic or the appli-  
cation of appropriate voltages (referenced to Common, pins 5 and 6).  
Output noise may be further reduced with the installation of additional external output  
filtering. See I/O Filtering and Noise Reduction.  
Calculated using the Telcordia (Bellcore) SR-332 Method 1, Case 3, ground fixed conditions,  
TA = +25°C, full load, natural convection, +55°C component temperature.  
Output ripple/noise (also referred to as periodic and random deviations  
or PARD) may be reduced below specified limits with the installation of  
additional external output capacitors. Output capacitors function as true filter  
www.murata-ps.com  
email: sales@murata-ps.com  
16 Dec 2009 MDC_LSN10A-D3.B03 Page 3 of 14  
LSN-10A D3 Models  
Single Output, Non-Isolated, 3.3VIN, 1-2.5VOUT, 10A, DC/DC's in SIP Packages  
elements and should be selected for bulk capacitance, low ESR, and appro-  
IR drops in conductors and/or cabling. Since these are non-isolated devices  
whose inputs and outputs usually share the same ground plane, sense is  
provided only for the +Output.  
priate frequency response. Any scope measurements of PARD should be  
made directly at the DC/DC output pins with scope probe ground less than  
0.5" in length.  
The remote sense line is part of the feedback control loop regulating the DC/  
DC converter’s output. The sense line carries very little current and conse-  
quently requires a minimal cross-sectional-area conductor. As such, it is not  
a low-impedance point and must be treated with care in layout and cabling.  
Sense lines should be run adjacent to signals (preferably ground), and in  
cable and/or discrete-wiring applications, twisted-pair or similar techniques  
should be used. To prevent high frequency voltage differences between VOUT  
and Sense, we recommend installation of a 1000pF capacitor close to the  
converter.  
All external capacitors should have appropriate voltage ratings and be located  
as close to the converters as possible. Temperature variations for all relevant  
parameters should be taken into consideration.  
The most effective combination of external I/O capacitors will be a function of  
your line voltage and source impedance, as well as your particular load and  
layout conditions.  
Input Fusing  
Most applications and or safety agencies require the installation of fuses at  
the inputs of power conversion components. LSN D3 Series DC/DC convert-  
ers are not internally fused. Therefore, if input fusing is mandatory, either a  
normal-blow or a fast-blow fuse with a value no greater than 17 Amps should  
be installed within the ungrounded input path to the converter.  
The sense function is capable of compensating for voltage drops between  
the +Output and +Sense pins that do not exceed 10ꢀ of VOUT.  
[VOUT(+) – Common] – [Sense(+) – Common] 10ꢀVOUT  
Power derating (output current limiting) is based upon maximum output  
current and voltage at the converter's output pins. Use of trim and sense  
functions can cause the output voltage to increase, thereby increasing output  
power beyond the LSN's specified rating. Therefore:  
As a rule of thumb however, we recommend to use a fast-blow fuse with a  
typical value of about twice the maximum input current, calculated at low line  
with the converters minimum efficiency.  
(VOUT at pins) x (IOUT) rated output power  
Safety Considerations  
The internal 10.5ꢂꢃresistor between +Sense and +Output (see Figure 1)  
serves to protect the sense function by limiting the output current flowing  
through the sense line if the main output is disconnected. It also prevents  
output voltage runaway if the sense connection is disconnected.  
LSN D3 SIP's are non-isolated DC/DC converters. In general, all DC/DC's  
must be installed, including considerations for I/O voltages and spacing/sepa-  
ration requirements, in compliance with relevant safety-agency speci-  
fications (usually UL/IEC/EN60950).  
Note: Connect the +Sense pin (pin 3) to +Output (pin 4) at the DC/DC  
converter pins, if the sense function is not used for remote regulation.  
In particular, for a non-isolated converter's output voltage to meet SELV  
(safety extra low voltage) requirements, its input must be SELV compliant.  
If the output needs to be ELV (extra low voltage), the input must be ELV.  
On/Off Control and Power-up Sequencing  
The On/Off Control pin may be used for remote on/off operation. LSN D3 SIP  
Series DC/DC's are designed so they are enabled when the control pin is  
left open (internal pull-down to Common) and disabled when the control pin  
is pulled high (+2.8V to +VIN), as shown in Figure 2 and 2a.  
Input Overvoltage and Reverse-Polarity Protection  
LSN D3 SIP Series DC/DC's do not incorporate either input overvoltage or  
input reverse-polarity protection. Input voltages in excess of the specified  
absolute maximum ratings and input polarity reversals of longer than "instan-  
taneous" duration can cause permanent damage to these devices.  
Dynamic control of the on/off function is best accomplished with a mechani-  
cal relay or open-collector/open-drain drive circuit. The drive circuit should  
be able to sink appropriate current when activated and withstand appropriate  
voltage when deactivated.  
Start-Up Time  
The VIN to VOUT Start-Up Time is the interval between the time at which a  
ramping input voltage crosses the lower limit of the specified input voltage  
range (3 Volts) and the fully loaded output voltage enters and remains within  
its specified accuracy band. Actual measured times will vary with input source  
impedance, external input capacitance, and the slew rate and final value of  
the input voltage as it appears to the converter.  
+INPUT  
5kΩ  
1.1kΩ  
ON/OFF  
CONTROL  
0.75kΩ  
The On/Off to VOUT Start-Up Time assumes the converter is turned off via  
the On/Off Control with the nominal input voltage already applied to the  
converter. The specification defines the interval between the time at which the  
converter is turned on and the fully loaded output voltage enters and remains  
within its specified accuracy band. See Typical Performance Curves.  
COMMON  
Figure 2. Driving the On/Off Control Pin with an Open-Collector Drive Circuit  
Remote Sense  
LSN D3 SIP Series DC/DC converters offer an output sense function on pin 3.  
The sense function enables point-of-use regulation for overcoming moderate  
The on/off control function, however, can be externally inverted so that the  
converter will be disabled while the input voltage is ramping up and then  
"released" once the input has stabilized.  
www.murata-ps.com  
email: sales@murata-ps.com  
16 Dec 2009 MDC_LSN10A-D3.B03 Page 4 of 14  
LSN-10A D3 Models  
Single Output, Non-Isolated, 3.3VIN, 1-2.5VOUT, 10A, DC/DC's in SIP Packages  
+INPUT  
ꢀ/54054  
4RIM  
5kΩ  
0.9kΩ  
ꢀ).054  
$OWN  
1.1kΩ  
42)-  
,/!$  
ON/OFF  
CONTROL  
4RIM  
5P  
#/--/.  
0.75kΩ  
#/--/.  
COMMON  
Figure 3.Trim Connections Using a Trimpot  
Figure 2a. Inverting On/Off Control Pin Signal and Power-Up Sequencing  
+OUTPUT  
For a controlled start-up of one or more LSN-D3's, or if several output volt-  
ages need to be powered-up in a given sequence, the On/Off Control pin can  
be pulled high (external pull-up resistor, converter disabled) and then driven  
low with an external open collector device to enable the converter.  
Trim  
+INPUT  
Down  
LOAD  
TRIM  
COMMON  
Trim Up  
Output Overvoltage Protection  
COMMON  
LSN D3 SIP Series DC/DC converters do not incorporate output overvolt-  
age protection. In the extremely rare situation in which the device’s feedback  
loop is broken, the output voltage may run to excessively high levels (VOUT =  
VIN). If it is absolutely imperative that you protect your load against any and  
all possible overvoltage situations, voltage limiting circuitry must be provided  
external to the power converter.  
Note: Install either a fixed trim-up resistor or a fixed trim-down resistor  
depending upon desired output voltage.  
Figure 4.Trim Connections Using Fixed Resistors  
LSN-1/10-D3 Trim Equations  
Output Overcurrent Detection  
ꢃꢄꢇꢅꢀ6/ n ꢈꢄꢉꢁ  
Overloading the output of a power converter for an extended period of time  
will invariably cause internal component temperatures to exceed their maxi-  
mum ratings and eventually lead to component failure. High-current-carrying  
components such as inductors, FET's and diodes are at the highest risk. LSN  
D3 SIP Series DC/DC converters incorporate an output overcurrent detection  
and shutdown function that serves to protect both the power converter and  
its load.  
n ꢃ  
n ꢃ  
24$/7. ꢀK7ꢁ ꢂ  
2450 ꢀK7ꢁ ꢂ  
6/ ./- n 6/  
ꢃꢄꢅꢆꢇ  
6/ n 6/  
./-  
LSN-1.2/10-D3, LSN-1.25/10-D3 Trim Equations  
If the output current exceeds it maximum rating by typically 60ꢀ (16 Amps)  
or if the output voltage drops to less than 98ꢀ of it original value, the  
LSN D3's internal overcurrent-detection circuitry immediately turns off the  
converter, which then goes into a "hiccup" mode. While hiccupping, the  
converter will continuously attempt to restart itself, go into overcurrent, and  
then shut down. Under these conditions, the average output current will be  
approximately 400mA, and the average input current will be approximately  
70mA. Once the output short is removed, the converter will automatically  
restart itself.  
ꢅꢄꢌꢆꢀ6/ n ꢈꢄꢉꢁ  
n ꢅꢄꢊꢋ  
n ꢅꢄꢊꢋ  
24$/7. ꢀK7ꢁ ꢂ  
2450 ꢀK7ꢁ ꢂ  
6/ ./- n 6/  
ꢃꢄꢆꢆꢅ  
6/ n 6/  
./-  
LSN-1.5/10-D3, LSN-1.8/10-D3,  
LSN-2/10-D3, LSN-2.5/10-D3 Trim Equations  
ꢅꢄꢊꢋꢀ6/ n ꢈꢄꢉꢁ  
n ꢌꢄꢆꢆ  
24$/7. ꢀK7ꢁ ꢂ  
2450 ꢀK7ꢁ ꢂ  
Output Voltage Trimming  
6/ ./- n 6/  
ꢃꢄꢉꢆꢇ  
Allowable trim ranges for each model in the LSN D3 SIP Series are 10ꢀ.  
Trimming is accomplished with either a trimpot or a single fixed resistor. The  
trimpot should be connected between +Output and Common with its wiper  
connected to the Trim pin as shown in Figure 3 below.  
n ꢌꢄꢆꢆ  
6/ n 6/  
./-  
Note: Resistor values are in k. Accuracy of adjustment is subject to  
tolerances of resistors and factory-adjusted, initial output accuracy.  
VO = desired output voltage. VONOM = nominal output voltage.  
A trimpot can be used to determine the value of a single fixed resistor  
which can then be connected, as shown in Figure 4, between the Trim pin  
and +Output to trim down the output voltage, or between the Trim pin and  
Common to trim up the output voltage. Fixed resistors should have absolute  
TCR’s less than 100ppm/°C to ensure stability.  
Output Reverse Conduction  
Many DC/DC converters using synchronous rectification suffer from Output  
Reverse Conduction. If those devices have a voltage applied across their  
output before a voltage is applied to their input (this typically occurs when  
another power supply starts before them in a power-sequenced application),  
The equations below can be used as starting points for selecting specific trim-  
resistor values. Recall, untrimmed devices are guaranteed to be 1ꢀ accurate.  
Adjustment beyond the specified 10ꢀ adjustment range is not recommended.  
www.murata-ps.com  
email: sales@murata-ps.com  
16 Dec 2009 MDC_LSN10A-D3.B03 Page 5 of 14  
LSN-10A D3 Models  
Single Output, Non-Isolated, 3.3VIN, 1-2.5VOUT, 10A, DC/DC's in SIP Packages  
+115°C (approx.), the thermal protection will disable the converter. Automatic  
restart occurs after the temperature has dropped below +110°C.  
they will either fail to start or self destruct. In both cases, the cause is the  
"freewheeling" or "catch" FET biasing itself on and effectively becoming a  
short circuit.  
In all cases below, the DUT's were vertical-mount models, and the direction  
of air flow was parallel to the unit in the direction from pin 1 to pin 11.  
LSN D3 SIP DC/DC converters are not damaged from Output Reverse  
Conduction. They employ proprietary gate drive circuitry which makes them  
immune to applied voltages during the startup sequence. If you are using  
an external power source paralleled with the LSN, be aware that during the  
start up phase, some low impedance condition or transient current may be  
absorbed briefly into the LSN output terminals before voltage regulation is  
fully established.You should insure that paralleled external power sources  
are not disrupted by this condition during LSN start up.  
As you may deduce from the above curves and can observe in the efficiency  
curves on the next page, LSN D3 SIP's are more efficient at lower current  
levels. Also, I2R losses in the output inductor are significantly less at lower  
currents. Consequently, LSN D3 SIP's deliver very impressive temperature  
performance if operating at less than full load.  
Lastly, when LSN D3 SIP's are installed in system boards, they are obviously  
subject to numerous factors and tolerances not taken into account above.  
If you are attempting to extract the most current out of these units under  
demanding temperature conditions, we advise you to monitor the output-  
inductor temperature to ensure it remains below +110°C at all times.  
Thermal Considerations and Thermal Protection  
The typical output-current thermal-derating curves shown above enable  
designers to determine how much current they can reliably derive from each  
model of the LSN D3 SIP's under known ambient-temperature and air-flow  
conditions. Similarly, the curves indicate how much air flow is required to  
reliably deliver a required output current at known temperatures.  
Thermal Performance for "H" Models  
Enhanced thermal performance can be achieved when LSN D3 SIP's are  
mounted horizontally ("H" models) and the output inductor (with its electrically  
isolating, thermally conductive pad installed) is thermally coupled to a copper  
plane/pad (at least 0.55 square inches in area) on the system board.Your  
conditions may vary, however our tests indicate this configuration delivers a  
16°C to 22°C improvement in ambient operating temperatures.  
The highest temperatures in LSN D3 SIP's occur at their output inductor,  
whose heat is generated primarily by I2R losses. The curves below were  
developed using thermocouples to monitor the inductor temperature and  
varying the load to keep that temperature below +110°C under the assorted  
conditions of air flow and air temperature. Once the temperature exceeds  
www.murata-ps.com  
email: sales@murata-ps.com  
16 Dec 2009 MDC_LSN10A-D3.B03 Page 6 of 14  
LSN-10A D3 Models  
Single Output, Non-Isolated, 3.3VIN, 1-2.5VOUT, 10A, DC/DC's in SIP Packages  
Start Up Considerations  
Solutions  
When power is first applied to the DC/DC converter, operation is different  
than when the converter is running and stabilized. There is some risk of start  
up difficulties if you do not observe several application features. Lower input  
voltage converters may have more problems here since they tend to have  
higher input currents. Operation is most critical with any combination of the  
following external factors:  
To improve start up, review the conditions above. One of the better solutions  
is to place a moderate size capacitor very close to the input terminals.You  
may need two parallel capacitors. A larger electrolytic or tantalum cap sup-  
plies the surge current and a smaller parallel low-ESR ceramic cap gives low  
AC impedance. Too large an electrolytic capacitor may have higher internal  
impedance (ESR) and/or lower the start up slew rate enough to upset the  
DC/DC’s controller. Make sure the capacitors can tolerate reflected switching  
current pulses from the converter.  
1 - Low initial input line voltage and/or poor regulation of the input source.  
2 – Full output load current on lower output voltage converters.  
3 – Slow slew rate of input voltage.  
The capacitors will not help if the input source has poor regulation. A  
converter which starts successfully at 3.3 Volts will turn off if the input voltage  
decays to below the input voltage theshold, regardless of external capaci-  
tance.  
4 – Longer distance to input voltage source and/or higher external input  
source impedance.  
Increase the input start up voltage if possible to raise the downward voltage  
spike. Also, make sure that the input voltage ramps up in a reasonably short  
time (less than a few milliseconds). If possible, move the input source closer  
to the converter to reduce ohmic losses in the input wiring. Remember that  
the input current is carried both by the wiring and the ground plane return.  
Make sure the ground plane uses adequate thickness copper. Run additional  
bus wire if necessary.  
5 - Limited or insufficient ground plane. External wiring that is too small.  
6 – Too small external input capacitance. Too high ESR.  
7 – High output capacitance causing a start up charge overcurrent surge.  
8 – Output loads with excessive inductive reactance or constant current  
characteristics.  
If the input voltage is already at the low limit before power is applied, the start  
up surge current may instantaneously reduce the voltage at the input termi-  
nals to below the specified minimum voltage. Even if this voltage depression  
is very brief, this may interfere with the on-board controller and possibly  
cause a failed start. Or the converter may start but the input current load will  
now drive the input voltage below its running low limit and the converter will  
shut down.  
Any added output capacitor should use just enough capacitance (and no  
more) to reduce output noise at the load and to avoid marginal threshold  
noise problems with external logic. An output cap will also “decouple”  
inductive reactance in the load. Certain kinds of electronic loads include  
“constant current” characteristics which destabilize the output with insufficient  
capacitance. If the wiring to the eventual load is long, consider placing this  
decoupling cap at the load. Use the Remote Sense input to avoid ohmic  
voltage drop errors.  
If you measure the input voltage before start up with a Digital Voltmeter  
(DVM), the voltage may appear to be adequate. Limited external capacitance  
and/or too high a source impedance may cause a short downward spike at  
power up, causing an instantaneous voltage drop. Use an oscilloscope not a  
DVM to observe this spike. The converter’s soft-start controller is sensitive to  
input voltage. What matters here is the actual voltage at the input terminals  
at all times.  
An elegant solution to start up problems is to apply the input voltage with the  
Remote On/Off control first in the off setting (for those converters with an  
On/Off Control). After the specified start-up delay (usually under 20 mSec),  
turn on the converter. The controller will have already been stabilized. The  
short delay will not be noticed in most applications. Be aware of applications  
which need “power management” (phased start up).  
Symptoms of start-up difficulties may include failed started, output oscillation  
or brief start up then overcurrent shutdown. Since the input voltage is never  
absolutely constant, the converter may start up at some times and not at  
others.  
Finally, it is challenging to model some application circuits with absolute fidel-  
ity. How low is the resistance of your ground plane? What is the inductance  
(and distributed capacitance) of external wiring? Even a detailed mathemati-  
cal model may not get all aspects of your circuit. Therefore it is difficult to  
give cap values which serve all applications. Some experimentation may be  
required.  
www.murata-ps.com  
email: sales@murata-ps.com  
16 Dec 2009 MDC_LSN10A-D3.B03 Page 7 of 14  
LSN-10A D3 Models  
Single Output, Non-Isolated, 3.3VIN, 1-2.5VOUT, 10A, DC/DC's in SIP Packages  
Typical Performance Curves for LSN D3 SIP Series  
LSN-2.5/10-D3  
Output Current vs. Ambient Temperature  
(Vertical mount, air flow direction from pin 1 to pin 11)  
,3.ꢀꢁꢂꢁꢃꢀ$ꢄꢅ ,3.ꢀꢁꢆꢇꢂꢁꢃꢀ$ꢄꢅ ,3.ꢀꢁꢆꢇꢈꢂꢁꢃꢀ$ꢄ  
/UTPUT #URRENT VSꢆ !MBIENT 4EMPERATURE  
ꢈ6ERTICAL MOUNTꢉ AIR FLOW DIRECTION FROM PIN ꢇ TO PIN ꢇꢇꢊ  
10  
8
ꢇꢂ  
.ATURAL #ONVECTION  
Natural Convection  
6
100 lfm  
ꢇꢂꢂ LFM  
4
ꢋꢂꢂ LFM  
200 lfm  
2
0
–40  
nꢁꢂ  
0
60  
70  
80  
90  
100  
110  
ꢃꢂ  
ꢄꢂ  
ꢅꢂ  
ꢆꢂ  
ꢇꢂꢂ  
ꢇꢇꢂ  
Ambient Temperature (°C)  
!MBIENT 4EMPERATURE ꢉo#ꢊ  
LSN-1.8/10-D3 & LSN-2/10-D3  
Output Current vs. Ambient Temperature  
(Vertical mount, air flow direction from pin 1 to pin 11)  
LSM-1/10-D3  
Efficiency vs. Line Voltage and Load Current  
91  
89  
87  
85  
83  
81  
79  
77  
75  
10  
8
Natural Convection  
6
100 lfm  
200 lfm  
V
IN = 3V  
4
V
IN = 3.3V  
2
V
IN = 3.6V  
0
–40  
0
60  
70  
80  
90  
100  
110  
Ambient Temperature (°C)  
1
2
3
4
5
6
7
8
9
10  
Load Current (Amps)  
LSN-1.5/10-D3  
Output Current vs. Ambient Temperature  
(Vertical mount, air flow direction from pin 1 to pin 11)  
LSM-1.2/10-D3  
Efficiency vs. Line Voltage and Load Current  
10  
8
92  
90  
88  
86  
84  
82  
80  
Natural Convection  
6
100 lfm  
200 lfm  
4
VIN = 3V  
2
V
IN = 3.3V  
0
–40  
V
IN = 3.6V  
0
60  
70  
80  
90  
100  
110  
Ambient Temperature (°C)  
1
2
3
4
5
6
7
8
9
10  
Load Current (Amps)  
www.murata-ps.com  
email: sales@murata-ps.com  
16 Dec 2009 MDC_LSN10A-D3.B03 Page 8 of 14  
LSN-10A D3 Models  
Single Output, Non-Isolated, 3.3VIN, 1-2.5VOUT, 10A, DC/DC's in SIP Packages  
Typical Performance Curves for LSN D3 SIP Series  
LSM-1.25/10-D3  
LSM-2/10-D3  
Efficiency vs. Line Voltage and Load Current  
Efficiency vs. Line Voltage and Load Current  
92  
91  
90  
89  
88  
87  
86  
85  
84  
83  
95  
94  
93  
92  
91  
90  
89  
88  
87  
V
IN = 3V  
V
IN = 3V  
V
IN = 3.3V  
V
IN = 3.3V  
V
IN = 3.6V  
V
IN = 3.6V  
1
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
10  
Load Current (Amps)  
Load Current (Amps)  
LSM-1.5/10-D3  
Efficiency vs. Line Voltage and Load Current  
LSM-2.5/10-D3  
Efficiency vs. Line Voltage and Load Current  
94  
93  
92  
91  
90  
89  
88  
87  
86  
85  
97  
96  
95  
94  
93  
92  
91  
90  
V
IN = 3V  
V
IN = 3V  
V
IN = 3.3V  
VIN = 3.3V  
V
IN = 3.6V  
VIN = 3.6V  
1
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
10  
Load Current (Amps)  
Load Current (Amps)  
LSM-1.8/10-D3  
Efficiency vs. Line Voltage and Load Current  
95  
94  
93  
92  
91  
90  
89  
88  
87  
V
IN = 3V  
V
IN = 3.3V  
VIN = 3.6V  
1
2
3
4
5
6
7
8
9
10  
Load Current (Amps)  
www.murata-ps.com  
email: sales@murata-ps.com  
16 Dec 2009 MDC_LSN10A-D3.B03 Page 9 of 14  
LSN-10A D3 Models  
Single Output, Non-Isolated, 3.3VIN, 1-2.5VOUT, 10A, DC/DC's in SIP Packages  
Typical Performance Curves for LSN D3 SIP Series  
Input Inrush Current  
Power-Up From VIN  
(VIN = 3.3V, 4300μF as Input Switch )  
(VIN = 3.3V, VOUT = 2.5V/10A, CIN/COUT = 220μF)  
100μsec/div  
2.5msec/div  
Input Reflected Ripple Current  
Power-Up From Enable  
(VIN = 3.3V, VOUT = 2.5V/10A, CIN/COUT = 220μF )  
(VIN = 3.3V, VOUT = 2.5V/10A, CIN/COUT = 220μF)  
2μsec/div  
2.5msec/div  
Input Reflected Ripple Current  
(VIN = 3.3V, VOUT = 2.5V/10A, Input Filter = 220μF/12μH/33μF,  
Power-Up From Enable  
C
OUT = 220μF )  
(VIN = 3.3V, VOUT = 2.5V/10A, CIN = 220μF, COUT = 5000μF, OSCON)  
2.5μsec/div  
2.5msec/div  
www.murata-ps.com  
email: sales@murata-ps.com  
16 Dec 2009 MDC_LSN10A-D3.B03 Page 10 of 14  
LSN-10A D3 Models  
Single Output, Non-Isolated, 3.3VIN, 1-2.5VOUT, 10A, DC/DC's in SIP Packages  
Typical Performance Curves for LSN D3 SIP Series  
Output Ripple/Noise  
Dynamic Load Response  
(VIN = 3.3V, VOUT = 2.5V, Full Load, COUT = 220μF)  
(VIN = 3.3V, 100% to 50% Load Step, COUT = 220μF)  
1μsec/div  
100μsec/div  
Output Ripple/Noise  
(VIN = 3.3V, VOUT = 2.5V, Full Load, No External Capacitor)  
Dynamic Load Response  
(VIN = 3.3V, VOUT = 2.5V, 100% to 0% Load Step, No External COUT)  
1μsec/div  
100μsec/div  
Dynamic Load Response  
(VIN = 3.3V, VOUT = 2.5V, 0% to 100% Load Step,  
COUT = 5000μF OSCON)  
Output Ripple/Noise  
(VIN = 3.3V, VOUT = 2.5V, No Load, No External Capacitor)  
1μsec/div  
100μsec/div  
www.murata-ps.com  
email: sales@murata-ps.com  
16 Dec 2009 MDC_LSN10A-D3.B03 Page 11 of 14  
LSN-10A D3 Models  
Single Output, Non-Isolated, 3.3VIN, 1-2.5VOUT, 10A, DC/DC's in SIP Packages  
Typical Performance Curves for LSN D3 SIP Series  
Input Current with Short Circuit at Output  
(VIN = 3.3V, VOUT = Short, IIN = 70mA Average,  
Output Hiccup  
(VIN = 3.3V, VOUT = Short, IIN = 70mA Average,  
IOUT = 400mA Average, CIN/COUT = 220μF, Period = 25msec )  
IOUT = 400mA Average, CIN/COUT = 220μF)  
2.5msec/div  
10msec/div  
Short-Circuit Output Current  
(VIN = 3.3V, VOUT = Short, IIN = 70mA Average,  
IOUT = 400mA Average, CIN/COUT = 220μF, Period = 25msec)  
500μsec/div  
www.murata-ps.com  
email: sales@murata-ps.com  
16 Dec 2009 MDC_LSN10A-D3.B03 Page 12 of 14  
LSN-10A D3 Models  
Single Output, Non-Isolated, 3.3VIN, 1-2.5VOUT, 10A, DC/DC's in SIP Packages  
LSN-2/10-D3 Radiated Emissions  
EN55022 Class B, 10 Meters  
E M I C O N D U C T E D / R A D I A T E D E M I S S I O N S  
Converter Output = +2Vdc @ +9.98 Amps  
If you’re designing with EMC in mind, please note that all of DATEL’s LSN  
D3 DC/DC Converters have been characterized for conducted and radiated  
emissions in our EMI/EMC laboratory. Testing is conducted in an EMCO  
5305 GTEM test cell utilizing EMCO automated EMC test software. Con-  
ducted/Radiated emissions are tested to the limits of FCC Part 15, Class B  
and CISPR 22 (EN 55022), Class B. Correlation to other specifications can  
be supplied upon request. The corresponding emissions plots to FCC and  
CISPR 22 for model LSN-2/10-D3 appear below.  
80  
70  
60  
50  
40  
30  
20  
10  
0
EN 55022 Class B Limit  
Radiated Emissions  
LSN-2/10-D3 Conducted Emissions  
FCC Part 15 Class B, EN55022 Class B Limit, +3.3Vdc @ 6.7A  
Converter Output = +2Vdc @ 10 Amps  
100  
–10  
–20  
100  
1000  
Frequency (MHz)  
90  
80  
70  
LSN-2/10-D3 Radiated Emissions  
FCC Part 15 Class B, 3 Meters  
Converter Output = +2Vdc @ 9.98 Amps  
EN55022 Class B Limit  
60  
80  
70  
60  
50  
40  
30  
20  
10  
0
50  
40  
30  
20  
FCC Class B Limit  
Conducted Emissions  
10  
0
0.1  
1.0  
Frequency (MHz)  
10.0  
Radiated Emissions  
–10  
–20  
100  
1000  
Frequency (MHz)  
www.murata-ps.com  
email: sales@murata-ps.com  
16 Dec 2009 MDC_LSN10A-D3.B03 Page 13 of 14  
LSN-10A D3 Models  
Single Output, Non-Isolated, 3.3VIN, 1-2.5VOUT, 10A, DC/DC's in SIP Packages  
P A R T N U M B E R S T R U C T U R E  
Options  
L SN - 1.8 / 10- D3 B H J - C  
Output  
Configuration:  
L = Unipolar  
Note:  
RoHS-6 hazardous  
substance compliant  
Some model number combinations may not be  
available. Contact Murata Power Solutions  
(DATEL).  
J Suffix:  
Low Voltage  
Reversed Pin, Vertical Mount  
H Suffix:  
Horizontal Mount  
Non-Isolated SIP  
Nominal Output Voltage:  
1, 1.2, 1.25, 1.5, 1.8, 2, or 2.5 Volts  
B Suffix:  
No Remote Sense  
(Pin 3 removed)  
Some options may require a special  
quantity order.  
Maximum Rated Output  
Current in Amps  
Input Voltage Range:  
D3 = 3 to 3.6 Volts  
(3.3V nominal)  
Reversed pin vertical mounting ("J" suffix)  
Functional Options  
This additional mechanical configuration consists of a low-profile pin header  
attached to the reverse side of the converter. It allows the LSN series to be  
mechanically compatible with Tyco's "keep out area."  
Remote Sense Pin Removed ("B" suffix)  
These devices have their +Sense pin (pin 3) removed, and the feedback  
loop is closed through the +VOUT path. The 10.5resistor in Figure 1 is  
installed in both standard and "B" models. See the Output Sense Function.  
Other Options and Modifications  
Other options include a positive polarity (pull low to disable) on the On/Off  
Control. Contact Murata Power Solutions (DATEL) directly to discuss these  
and other possible modifications.  
Horizontal Mounting ("H" suffix)  
This packaging configuration reduces above-board height to 0.35" (8.89mm)  
including the "pad." For "H" models, a thermally conductive, electrically  
insulating "pad" is factory installed on the output inductor. The pad material is  
Bergquist Sil Pad 400. The pad size is 0.4 x 0.5 x 0.009 inches (10.16 x 12.7  
x 0.23mm). This configuration can significantly improve thermal performance.  
See Thermal Derating for details.  
Examples  
LSN-1.8/10-D3  
LSN-1.8/10-D3B  
LSN-1.8/10-D3H  
Vertical-mount. Sense function on pin 3. No pin 9.  
Vertical-mount. Pin 3 (+Sense) removed. No pin 9.  
Horizontal-mount. Sense function on pin 3. No pin 9.  
Sense Pins  
LSN-1.8/10-D3BH Horizontal-mount. Pin 3 (+Sense) removed. No pin 9.  
Note: If the sense pin is installed, it must be connected to either a remote  
load or to +output at the converter pins. Do not leave sense unconnected.  
LSN-1.8/10-D3J  
Reverse pin vertical-mount. Sense function on pin 3.  
No pin 9.  
LSN-1.8/10-D3HJHL2-C  
Reverse pin vertical mount, conformal  
coating added, special pin length, RoHS-6 hazardous  
substance compliance.  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
ISO 9001 and 14001 REGISTERED  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
notice.  
© 2009 Murata Power Solutions, Inc.  
www.murata-ps.com/locations  
email: sales@murata-ps.com  
16 Dec 2009 MDC_LSN10A-D3.B03 Page 14 of 14  

相关型号:

LSN-1.25/10-D3BH

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, SIP-11/9
MURATA

LSN-1.25/10-D3BH-C

DC-DC Regulated Power Supply Module, 1 Output, 12.5W, Hybrid, ROHS COMPLIANT, SIP-9/11
MURATA

LSN-1.25/10-D3BJ

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, SIP-11/9
MURATA

LSN-1.25/10-D3H

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, SIP-11/10
MURATA

LSN-1.3/10-D12

Single Output, Non-Isolated, 12VIN, 1-5VOUT, 10A, DC/DCs in SIP Packages
MURATA

LSN-1.3/10-D12-C

暂无描述
MURATA

LSN-1.3/10-D12B

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, SIP-11/10
MURATA

LSN-1.3/10-D12BH

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, SIP-11/10
MURATA

LSN-1.3/10-D12BH-C

DC-DC Regulated Power Supply Module, 1 Output, 13W, Hybrid, ROHS COMPLIANT, SIP-9/11
MURATA

LSN-1.3/10-D12BHJ-C

DC-DC Regulated Power Supply Module
MURATA

LSN-1.3/10-D12BJ

暂无描述
MURATA

LSN-1.3/10-D12H-C

DC-DC Regulated Power Supply Module, 1 Output, 13W, Hybrid, ROHS COMPLIANT, SIP-10/11
MURATA