MYPMA01218RCF-CAB [MURATA]

120W DC-DC converter(216W peak);
MYPMA01218RCF-CAB
型号: MYPMA01218RCF-CAB
厂家: muRata    muRata
描述:

120W DC-DC converter(216W peak)

文件: 总6页 (文件大小:622K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MYPMA01218RCF-CAB  
Non-isolated type  
FEATURES  
DESCRIPTION  
120W DC-DC converter(216W peak)  
Output Voltage:12V  
Low ripple and Low surge output.  
Input Voltage:36V-75V  
Working Temperature -20 - +85℃  
High Efficiency up to 95%  
Compact Size 86.5x122.4x35.4mm  
Small and Lightweight(160g)  
IP56 compliance  
MYPMA01218RCF-CAB is an ultra-efficient,  
non-isolated DC-DC converter providing  
216W power at 12V output. The small and  
lightweight converter is packaged in a plastic  
case conforming to IP56 standard.  
Originally designed for lighting application on  
the E-motorcycle, E-scooter, E-tricycle and  
E-super small car using non-automotive  
grade components, the converter is suitable  
for a wide variety of industrial and commercial  
applications.  
Vibration-proof case design  
Over Temperature Protection  
Built-in Over-current and short circuit  
protection circuit  
RoHS Compliant  
Connection Diagram  
Vout12  
VIN  
A
V
Vr  
A
V
RL  
MYPMA01218RCF-CAB  
VIN  
GND  
(Output)  
GND  
(Input)  
A
V
Digital Multi meter  
HP34401A equivalent (Agilent Technologies)  
RM101 equivalent (Keisoku Giken )  
ELL355 equivalent (Keisoku Giken)  
HP6675A equivalent ( Agilent Technologies)  
Vr  
Ripple Voltmeter  
Electronic Load Device  
DC Power Supply  
RL  
GND terminals are connected inside of DC-DC converter. However, please make sure that they are  
to be connected outside in order to prevent DC-DC converter from malfunction by noise.  
This information is subject to change without notice. Please contact our sales or product engineers to confirm the latest before  
purchasing.  
www.murata.co.jp  
P1/6  
March 2, 2016  
MYPMA01218RCF-CAB  
Non-isolated type  
Performance Specifications Summary  
Output  
Input  
Efficiency  
Rlpple  
(mVp-p)  
Regulation  
(Max)**  
Iout(Amps)**  
Vin  
Nom.  
Range  
**  
Vout  
(Volts)  
Power  
Min. Typ.  
(Min)  
(Max)  
10  
(Peak)  
(Typ.)  
Line  
±5%  
Load  
Model Number  
(Watts)  
(Volts) (Volts)  
**  
**  
MYPMA01218RCF-CAB  
12  
1
18  
120  
150  
±5%  
48, 60 36-75  
90  
95  
@Ta=25  
Functional Specifications  
Input  
Environmental  
Estimated life Expectancy for  
Electrolytic Capacitor (Note 1)  
Operating Temperature Range  
with de-rating  
Input Voltage Range  
Isolation  
See performance Specification  
Not isolated. Input and output  
Commons are internally connected  
29.9Vdc  
27.3Vdc  
None  
Capacitive  
None, install external fuse.  
20A  
UVLO  
None  
4 years or more  
-20 to +85  
Start-Up Voltage  
Storage Temperature Range  
Operating Humidity Range  
Storage Humidity Range  
-30 to +85℃  
+20 to +95%  
+10 to +90%  
+140°C  
Undervoltage Shutdown  
Overvoltage Shutdown  
Internal Input Filter Type  
Reverse Polarity Protection  
Recommended External Fuse  
Shutdown Mode  
Thermal Protection/Shutdown  
Physical  
Outline Dimensions  
Tightening torque  
Weight  
Vibration  
Shock  
See Mechanical Specifications  
1.51Nm max. for each M5 screw  
160g  
10G at 10-2000Hz,4Hrs ×3 axis  
40G at 100 bumps/6msec ×3 axis  
No registered Number..  
Remote ON/Off Control  
Output  
Output Voltage**  
Ripple/Noise  
Line/Load Regulation  
DC Load Output Current  
Current Limit Inception  
Efficiency  
See Performance Specification  
See Performance Specification  
See Performance Specification  
See Performance Specification  
20A  
Safety Standard  
UL60950/IEC 60950  
However the enclosure is made  
from UL94V-0 equivalent materials.  
International Protection Code  
IEC60529  
IP-56, exclude connector.  
See Performance Specification  
Short Circuit Protection  
Specification Note:  
Hiccup auto-recovery upon  
overload removal.  
Continuous, no damage(output  
shorted to ground).  
Protection Method  
(1)Rated load, ambient air temperature of 65°C.  
Surface temperature of a maximum of 95°C of the metal plate.  
3 hours in operation per one day  
Short Circuit Duration  
Over Temperature Protection  
Protective Method  
Autorecovery upon over  
temperature removal.  
Continuous, no damage  
Converter will start up if the  
external output voltage is less than  
Vnominal.  
Over Temperature Duration  
Pre-bias Startup  
Dynamic Characteristics  
Start Up Time (Vin on to Vout  
regulated or On/Off to Vout)  
< 100msecs.  
102kHz  
Switching Frequency  
Reliability test Specifications  
Reliability Test  
Expose 100hrs in +65℃±3with 48Vin.  
Expose 100hrs in +65℃±3/90%RH with 10A load and 48Vin.  
High temperature load test  
High temperature high humidity load test  
ESD test  
Expose condition A(r=1500Ω, C=100pF) on EIAJ ED-4701 method C-111.  
Expose 100 cycles in the following sequence..-40℃±3/30min->, Room  
temperature(+25)/10sec->+85℃±3/30min->Room temperature(+25)/10sec.  
Temperature cycling test  
After above test, hold in the room temperature(+25) for 24hrs, then measure above parameters indicated (**) in the above specification.  
This information is subject to change without notice. Please contact our sales or product engineers to confirm the latest before  
purchasing.  
www.murata.co.jp  
P2/6  
March 2, 2016  
MYPMA01218RCF-CAB  
Non-isolated type  
Typical Performance Data  
Efficiency vs. Line Voltage and Load Current @Ta=+25℃  
Maximum Current Temperature De-rating at Sea Level  
Ripple and Noise (Vin = 36V, Iout = 10A,Scope Bandwidth = 20MHz)  
Trace 1 = Vout 100mV/div ,Trace 2 = Vin 500mV/div  
Turn On Delay (Vin = 36V, Iout = 10A,)  
Trace1 = Vout 5V/div , Trace 2 = Vin 50V/div  
Ripple and Noise (Vin = 48V, Iout = 10A,Scope Bandwidth = 20MHz)  
Trace 1 = Vout 100mV/div ,Trace 2 = Vin 500mV/div  
Turn On Delay (Vin = 48V, Iout = 10A,)  
Trace1 = Vout 5V/div, Trace 2 = Vin 50V/div  
This information is subject to change without notice. Please contact our sales or product engineers to confirm the latest before  
purchasing.  
www.murata.co.jp  
P3/6  
March 2, 2016  
MYPMA01218RCF-CAB  
Non-isolated type  
Typical Performance Data  
Ripple and Noise (Vin = 60V, Iout = 10A,Scope Bandwidth = 20MHz)  
Turn On Delay (Vin = 60V, Iout = 10A,)  
Trace 1 = Vout 100mV/div ,Trace 2 = Vin 500mV/div  
Trace1 = Vout 5V/div, Trace 2 = Vin 50V/div  
Ripple and Noise (Vin = 75V, Iout = 10A,Scope Bandwidth = 20MHz)  
Trace 1 = Vout 100mV/div ,Trace 2 = Vin 500mV/div  
Turn On Delay (Vin = 75V, Iout = 10A,)  
Trace1 = Vout 5V/div, Trace 2 = Vin 50V/div  
This information is subject to change without notice. Please contact our sales or product engineers to confirm the latest before  
purchasing.  
www.murata.co.jp  
P4/6  
March 2, 2016  
MYPMA01218RCF-CAB  
Non-isolated type  
Mechanical Specifications  
23.78±0.5  
74±0.5  
VLP-06V-1 (JST)  
3 2 1  
□□□ □□□  
6 5 4  
MURATA  
MYPMA01218RCF-CAB  
Recommended female connector :  
VLR-06V (JST)  
(35)  
122.36±0.5  
Input/output Connections P72  
Pad Function  
Wire Color  
1
2
3
4
5
6
N.C.  
-
N.C.  
-
Vout12  
Vin  
Orange  
Red  
Black  
Blue  
GND(Input)  
GND(Output)  
The connector of the converter is not waterproof.  
Proper precautions should be taken to keep the converter water and  
dust free, to avoid a short-circuit.  
Frame should be assembled using M5 screws, with a maximum  
torque of 1.51Nm.  
Maximum allowable temperature on metal plate is 95°C.  
Do not expose this product to direct sunlight.  
Packaging Specification  
Item  
Packaging form typical classification  
Dimensions of packaging form  
Specification  
Box  
W
D
=
540 ( mm )  
355 ( mm )  
255 ( mm )  
H
=
H
=
W
D
The number of products in a packaging form  
Remark  
Minimum order quantity is 105pcs. (3boxes * 35pcs/box. = 105pcs.)  
35 ( pcs. )  
This information is subject to change without notice. Please contact our sales or product engineers to confirm the latest before  
purchasing.  
www.murata.co.jp  
P5/6  
March 2, 2016  
MYPMA01218RCF-CAB  
Non-isolated type  
Note prior to use  
Functional Specifications  
If you apply high static electricity, voltage higher than rated voltage or  
reverse voltage to the product, it may cause defects in the products or  
degrade the reliability.  
Please avoid the following items:  
1. Over rating power supply, reverse power supply or not-enough  
connection of input voltage and 0V(DC)line  
Please contact Murata Sales before using this product for the  
applications listed below. These are applications that require very high  
reliability of prevention of defects which might directly cause damage  
to third party’s life, body, or property.  
1. Aircraft equipment  
2. Aerospace equipment  
2. Electrostatic discharge by production line and/or operator  
3. Electrified product by electrostatic induction  
3. Undersea equipment  
4. Power plant control equipment  
5. Medical equipment  
6. Transportation equipment (cars, buses, trucks, trains, ships, etc.)  
7. Traffic signal equipment  
8. Disaster prevention /crime prevention equipment  
9. Data-processing equipment  
10. Application of similar complexity and /or reliability  
• Do not subject product to excessive mechanical shock. If you drop  
the product on the floor it might cause a crack to the core of inductors  
and monolithic ceramic capacitors.  
• Also please pay attention to handling; the mounted parts can be  
dislodged if subjected to excessive force.  
• Input and output wiring cords should have slack so that they do not  
exert stress to the input/output connectors of the product. Subjecting  
the connectors to sustained stress may damage the product.  
Storage  
Please store this product in an environment where the  
temperature/humidity is stable in the range 0 to 40°C/10 to 75%RH  
and no direct sunlight. Use the product within 6 months after delivery.  
Please avoid storage conditions where humidity and temperature  
change rapidly, as that may cause condensation on the product, which  
might degrade the quality of the product.  
This product may rust after a long time (more than 1 year) storage.  
Please do not store the product environments that are dusty, in direct  
exposure to sea breeze, or in an atmosphere containing corrosive gas  
(Cl2, NH3, SO2, NOX and so on).  
Assembly  
Assemble the frame by using M5 screws, with a torque of 1.51Nm  
[reference only]  
Transportation  
If you transport the product, please pack it so that the package will not  
be damaged by mechanical vibration or mechanical shock, and please  
educate and guide the carrier to prevent rough handling.  
If you transport the products overseas (in particular, by sea), it is  
expected that the transportation environment will be the worst, so  
please pack the products in a package that is mechanically strong,  
vibration-resistant, and humidity-resistant. The packaging of the  
products that Murata sells in Japan may not be suitable overseas  
transport. Please consult Murata Sales if you plan to use the standard  
Murata packaging of the products for transport to overseas.  
Operational environment and operational conditions  
Operational environment  
This product is not chemical-proof or rust-proof.  
In order to prevent this product from leakage of electricity and/or  
abnormal temperature increase, do not use the product under the  
following circumstances:  
(1) in an atmosphere containing corrosive gas (Cl2, NH3, SO2, NOX  
and so on).  
(2) in a dusty place.  
(3) in a place exposed to direct sunlight.  
(4) in such a place where water splashes or in such a humid place  
where water condenses.  
Note  
1. Please make sure that the product has been evaluated and  
confirmed against your specifications when it is mounted to your  
product.  
2. All the items and parameters in this product specification have been  
prescribed on the premise that our product is used for the purpose,  
under the conditions and in the environment agreed upon between  
you and us. You are requested not to use our product deviating from  
such agreement.  
3. We consider it not appropriate to include other terms and conditions  
for transaction warranty in product specifications, drawings or other  
technical documents. Therefore, if your technical documents as  
above include such terms and conditions as warranty clause, product  
liability clause, or intellectual property infringement liability clause, we  
will not be able to accept such terms and conditions unless they are  
based on the governmental regulation or they are stated in a  
separate contract agreement.  
(5) in a place exposed to sea breeze.  
(6) in any other places similar to the above (1)through (5).  
Operational conditions  
Please use the product within specified values (power supply,  
temperature, input, output and load condition etc.). Input voltage drops  
for line impedance, so please make sure that input voltage is within in  
specified values.  
If the product is used over the specified values, it may damage the  
product, reduce the quality, and even if the products can endure the  
condition for short time, it may cause degradation of the reliability.  
This information is subject to change without notice. Please contact our sales or product engineers to confirm the latest before  
purchasing.  
www.murata.co.jp  
P6/6  
March 2, 2016  

相关型号:

MYQ4ZN-AC110/120

Power/Signal Relay,
OMRON

MYRGM080150B31RA

民用设备,工业设备
MURATA

MYRGM080150W31RA

民用设备,工业设备
MURATA

MYRGM085150B31RA

民用设备,工业设备
MURATA

MYRGM085150W31RA

民用设备,工业设备
MURATA

MYRGM090150B31RA

民用设备,工业设备
MURATA

MYRGM090150W31RA

民用设备,工业设备
MURATA

MYRGM095150B31RA

Switching Regulator,
MURATA

MYRGM095150W31RA

Switching Regulator,
MURATA

MYRGM100150B31RA

民用设备,工业设备
MURATA

MYRGM100150W31RA

民用设备,工业设备
MURATA

MYRGM105150B31RA

民用设备,工业设备
MURATA