NTA Series
Isolated 1W Dual Output SM DC/DC Converters
SELECTION GUIDE
Nominal
Input
Voltage
Input
Current at
Rated Load
Output
Voltage
Output
Current
Isolation
Capacitance
Efficiency
MTTF2
Order Code1
V
3.3
3.3
3.3
3.3
3.3
5
V
3.3
5
mA
152
100
55
mA
402
388
405
390
392
259
290
251
267
260
256
121
113
111
110
%
75
78
75
77
77
77
69
80
75
77
78
69
74
75
76
pF
29
30
34
40
42
31
33
42
38
44
43
50
72
89
100
kHrs
1005
399
827
375
206
964
1697
367
682
343
188
559
375
243
154
NTA0303MC
NTA0305MC
NTA0309MC
NTA0312MC
NTA0315MC
NTA0503MC
NTA0505MC
NTA0505MEC
NTA0509MC
NTA0512MC
NTA0515MC
NTA1205MC
NTA1209MC
NTA1212MC
NTA1215MC
9
12
15
3.3
5
42
33
152
100
100
55
FEATURES
ꢀRoHS compliant
5
5
5
5
9
ꢀEfficiency up to 78%
5
12
15
5
42
ꢀWide temperature performance at full
1 Watt load, –40°C to 85°C
5
33
12
12
12
12
100
55
9
ꢀUL 94V-0 Package material
ꢀFootprint over pins 1.64cm2
ꢀLead frame technology
ꢀ3.3V, 5V & 12V Input
12
15
42
33
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external
capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the
additional external capacitance for reliable start up.
ꢀ3.3V, 5V, 9V, 12V & 15V Output
ꢀInternal SMD construction
ꢀToroidal magnetics
INPUT CHARACTERISTICS
Parameter
Conditions
Min.
2.97
4.5
Typ.
3.3
5
Max.
3.63
5.5
Units
V
Continuous operation, 3V input types
Continuous operation, 5V input types
Continuous operation, 12V input types
Voltage range
ꢀ1kVDC Isolation
10.8
12
41
13.2
50
Reflected ripple current
mA p-p
ꢀMTTF up to 2.1 Million hours
ꢀPower density 1.36W/cm3
ꢀNo heatsink required
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
1000
10
Typ.
Max.
Max.
Units
VDC
GΩ
Isolation voltage
Resistance
Flash tested for 1 second
Viso= 1000VDC
ꢀCustom solutions available
ꢀMulti-layer ceramic capacitors
GENERAL CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
100
110
115
Units
kHz
PRODUCT OVERVIEW
The NTA series of miniature surface mounted
DC/DC Converters employ leadframe
technology and transfer moulding techniques
to bring all of the benefits of IC style
packaging to hybrid circuitry. Co-planarity of the
lead positions is based upon IEC 191-6:1990. The
devices are suitable for all applications where
high volume production is envisaged.
0312MC, 0315MC
Switching frequency
0303MC, 0305MC, 0503MC, 0505MEC
All other variants
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection3
1 second
300°C
700mW
5.5V
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
Input voltage VIN, NTA03 types
Input voltage VIN, NTA05 types
Input voltage VIN, NTA12 types
7V
15V
1. If components are required in tape and reel format suffix order code code with -R, e.g. NTA0505MC-R.
2. Calculated using MIL-HDBK-217F with nominal input voltage at full load.
3. Supply voltage must be disconnected at the end of the short circuit duration.
All specifications typical at T =25°C, nominal input voltage and rated output current unless otherwise specified.
A
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232
KDC_NTA.G04 Page 1 of 4
NTA Series
Isolated 1W Dual Output SM DC/DC Converters
OUTPUT CHARACTERISTICS
Parameter
Rated Power
Conditions
TA=-40°C to 85°C
Min.
Typ.
Max.
1.0
Units
W
Voltage Set Point Accuracy
Line regulation
See tolerance envelope
High VIN to low VIN
1.0
10
10
9.0
6.5
11
6.0
6.0
40
50
35
50
65
1.2
15
%/%
%
10% load to rated load, 0303MC & 0503MC
10% load to rated load, 5V output types
10% load to rated load, 0309MC
12
10
Load Regulation1
Ripple and Noise
10% load to rated load, 0509MC & 1209MC
10% load to rated load, 0312MC & 0315MC
10% load to rated load, 0512MC & 1212MC
10% load to rated load, 0515MC & 1215MC
BW=DC to 20MHz, 3.3V output types, NTA0305MC & NTA0505MEC
BW=DC to 20MHz, all other 5V output types
BW=DC to 20MHz, 9V output types
BW=DC to 20MHz, 12V output types
BW=DC to 20MHz, 15V output types
8.0
14
8.5
7.0
80
100
80
mV p-p
110
110
TEMPERATURE CHARACTERISTICS
Parameter
Specification
Storage
Conditions
All output types
Min.
-40
Typ.
Max.
85
Units
°C
-55
125
0305MC, 0505MEC, 0312MC, 0315MC
0303MC, 0309MC, 0503MC
0505MC, 1205MC
19
25
46
35
Case temperature rise above
ambient
All other variants
Cooling
Free air convection
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NTA series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specific agency approvals, such as the NTA series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NTA series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
TEMPERATURE DERATING GRAPH
RoHS COMPLIANCE INFORMATION
1.5
This series is compatible with RoHS soldering systems with
a peak reflow solder temperature of 245ºC and time above
liquidus of 217ºC for 80 seconds. The pin termination finish
on this product series is Gold, plating thickness 0.1 microns
minimum. The series is backward compatible with Sn/Pb
soldering systems.
85°C
1.0
0.5 Safe Operating Area
For further information, please visit www.murata-ps.com/rohs
0
-40
100
150
0
50
Ambient Temperature (°C)
1. 12V input types have typically 3% less load regulation change.
www.murata-ps.com
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232
KDC_NTA.G04 Page 2 of 4
NTA Series
Isolated 1W Dual Output SM DC/DC Converters
TOLERANCE ENVELOPES
Tolerance Envelope - 3.3V output types.
+9%
All other types.
+10%
+5%
VNOM
+2.5%
-2.5%
-7.5%
+1%
VNOM
+1%
-7%
-7%
-15%
100
75
Output Load Current (%)
100
10 25
50
75
10 25
50
Output Load Current (%)
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS
0.600 (15.24)
0.400 (10.16)
Pin
1
Function
-VIN
+VIN
NA
18
16
10
14
12
3
0.441
5
0.020(0.5)
REFERENCE
PLANE
0.409 0.303
(11.20)
(7.70)
7
OV
NTA0505MC
XYYWW
(10.40)
P
9
-VOUT
NA
0.059(1.50)
0.047(1.20)
10 PINS
5
1
3
7
9
10
12
14
16
18
°
5.00
+VOUT
NA
0.026(0.65)
0.022(0.55)
S
0.008(0.2)
0.100(2.54)
NA
0.083
(2.10)
NA
DETAIL A
0.250 (6.35)
0.260 (6.6)
0.234 (5.95) 0.230 (5.85)
SEATING PLANE
S
0.010 (0.25)
0.004 (0.10)
NA - Not available for electrical connection.
10 PINS
0.004 (0.1)
0.074
(1.875) MAX
0.012 (0.30)
0.008 (0.20)
0.11 (2.79) MAX
S
All dimensions in inches 0.01 (mm 0.25mm). All pins on a 0.1 (2.54) pitch.
Weight: 1.53g
RECOMMENDED FOOTPRINT DETAILS
TUBE OUTLINE DIMENSIONS
ꢌꢀꢁꢀꢄꢉꢀꢁꢀꢀꢋꢌꢅꢀꢁꢋꢀꢀꢁꢊꢍꢈ
ꢀꢁꢀꢃꢂꢌꢅꢄꢁꢊꢀꢈ
ꢀꢁꢉ
ꢅꢊꢀꢁꢊꢋꢈ
ꢀꢁꢀꢇꢆ
ꢅꢄꢁꢀꢀꢈ
ꢀꢁꢍꢋꢍꢌꢅꢊꢉꢁꢂꢍꢈ
ꢀꢁꢂꢇꢀꢌꢅꢆꢁꢉꢀꢈ
ꢀꢁꢂꢃꢄ
ꢅꢆꢁꢇꢀꢈ
ꢀꢁꢄꢋꢉꢌꢅꢋꢁꢇꢀꢈ
ꢀꢁꢊꢅꢄꢁꢍꢉꢈ
ꢀꢁꢀꢉꢌꢅꢊꢁꢀꢀꢈꢌ.*/
Unless otherwise stated all dimensions in inches 0.02 (mm 0.5).
Tube length : 18.70 0.07 (475 2.0).
Tube Quantity : 25
www.murata-ps.com
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232
KDC_NTA.G04 Page 3 of 4
NTA Series
Isolated 1W Dual Output SM DC/DC Converters
TAPE & REEL SPECIFICATIONS
REEL OUTLINE DIMENSIONS
TAPE OUTLINE DIMENSIONS
ꢊꢄꢁꢆꢆ
ꢅꢂꢂꢀꢈꢌ."9
ꢀꢁꢋꢄ
ꢅꢊꢍꢁꢇꢍꢈ
ꢀꢁꢀꢄꢌꢅꢀꢁꢋꢀꢈꢌ."9
ꢂꢁꢆꢉ
ꢅꢊꢀꢀꢈꢌ.*/
ꢏꢀꢁꢀꢀꢉꢌꢅꢏꢀꢁꢊꢀꢈ
ꢎꢀꢁꢀꢀꢌꢅꢎꢀꢁꢀꢀꢈ
ꢀꢁꢀꢋꢌꢅꢊꢁꢍꢀꢈ
ꢀꢁꢋꢂꢌꢅꢊꢋꢁꢀꢀꢈ
ꢀꢁꢍꢊꢀꢁꢀꢀꢆ
ꢅꢊꢂꢁꢀꢀꢀꢁꢄꢍꢈ
ꢀꢁꢀꢃꢌ
ꢅꢄꢁꢀꢀꢈ
ꢀꢁꢉꢋꢌ
ꢅꢊꢊꢁꢋꢀꢈ
ꢀꢁꢊꢋꢌ
ꢅꢉꢁꢀꢀꢈ
ꢀꢁꢄꢋ
ꢅꢋꢁꢋꢀꢈ
ꢀꢁꢀꢇꢅꢊꢁꢇꢍꢈ
ꢀꢁꢉꢍꢌ
ꢅꢊꢊꢁꢍꢀꢈ
ꢀꢁꢆꢉꢀꢁꢀꢉ
ꢅꢄꢉꢁꢀꢀꢀꢁꢂꢀꢈ
REEL PACKAGING DETAILS
CARRIER TAPE START
3.94 (100) MIN
TRAILER SECTION
6.30 (160) MIN
GOODS ENCLOSURE
SECTION
Product Orientation
Pin 1, located nearest to
carrier drive sprocket.
LEADER SECTION
15.75 (400) MIN
Reel Quantity : 500
USA:
Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com
UK: Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com
Tucson (Az), Tel: (800) 547 2537, email: sales@murata-ps.com
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com
Germany: München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com
Japan: Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com
Website: www.murata-ps.jp
www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
China:
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
notice.
© 2008 Murata Power Solutions, Inc.
www.murata-ps.com
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232
KDC_NTA.G04 Page 4 of 4
相关型号:
NTA0305XMC
1W, FIXED INPUT, ISOLATED DUAL OUTPUT SMD DC-DC CONVERTER 功率1W,定电压输入,隔离1500VDC,双输出,SMD贴片封装DC-DC电源模块转换器
MICRODC
NTA0309XMC
1W, FIXED INPUT, ISOLATED DUAL OUTPUT SMD DC-DC CONVERTER 功率1W,定电压输入,隔离1500VDC,双输出,SMD贴片封装DC-DC电源模块转换器
MICRODC
NTA0312XMC
1W, FIXED INPUT, ISOLATED DUAL OUTPUT SMD DC-DC CONVERTER 功率1W,定电压输入,隔离1500VDC,双输出,SMD贴片封装DC-DC电源模块转换器
MICRODC
©2020 ICPDF网 联系我们和版权申明