Isolated 1W Single Output SM DC/DC Converters
SELECTION GUIDE
Nominal
Input
Voltage
Input
Output
Voltage
Output
Current
Isolation
Capacitance
Current at Efficiency
Rated Load
MTTF2
Order Code1
V
3.3
3.3
3.3
3.3
3.3
5
V
3.3
5
mA
303
200
111
83
mA
410
390
400
400
400
270
294
260
278
267
260
256
124
114
113
111
%
73
78
77
77
77
74
68
77
72
75
77
78
67
73
74
75
pF
30
35
31
28
29
40
35
40
39
43
42
44
47
77
88
95
kHrs
5348
3847
3134
3473
2473
5515
6857
3933
6677
5501
3957
2747
4683
4008
3121
2316
NTE0303MC
NTE0305MC
NTE0309MC
NTE0312MC
NTE0315MC
NTE0503MC
NTE0505MC
NTE0505MEC
NTE0506MC
NTE0509MC
NTE0512MC
NTE0515MC
NTE1205MC
NTE1209MC
NTE1212MC
NTE1215MC
9
12
15
3.3
5
FEATURES
ꢀRoHS compliant
66
303
200
200
167
111
83
5
ꢀLead frame technology
ꢀSingle isolated output
ꢀ1kVDC Isolation
5
5
5
6
5
9
5
12
15
5
ꢀEfficiency up to 78%
ꢀPower density 1.8W/cm3
5
66
12
12
12
12
200
111
83
9
ꢀWide temperature performance at full
1 Watt load, –40°C to 85°C
12
15
66
ꢀUL 94V-0 Package material
ꢀFootprint over pins 1.37cm2
ꢀ3.3V, 5V & 12V Input
INPUT CHARACTERISTICS
Parameter
Conditions
Min.
2.97
4.5
Typ.
3.3
Max.
3.63
5.5
Units
V
Continuous operation, 3.3V input types
Continuous operation, 5V input types
Continuous operation, 12V input types
Voltage range
5.0
ꢀ3.3V, 5V, 9V, 12V & 15V output
ꢀNo heatsink required
10.8
12.0
30
13.2
47
Reflected ripple current
mA p-p
ꢀInternal SMD construction
ꢀToroidal magnetics
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
1000
10
Typ.
Max.
Max.
Units
VDC
GΩ
ꢀMTTF up to 6.8 million hours
ꢀCustom solutions available
ꢀMulti-layer ceramic capacitors
Isolation voltage
Resistance
Flash tested for 1 second
Viso= 1000VDC
GENERAL CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
110
Units
kHz
Switching frequency
All output types
PRODUCT OVERVIEW
The NTE series of miniature surface mounted
DC/DC Converters employ leadframe technol-
ogy and transfer moulding techniques to bring
all of the benefits of IC style packaging to hybrid
circuitry. The co-planarity of the pin positions is
based upon IEC 191-6:1990. The devices are
suitable for all applications where high volume
production is envisaged.
ABSOLUTE MAXIMUM RATINGS
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
300°C
600mW
5.5V
Input voltage VIN, NTE03 types
Input voltage VIN, NTE05 types
7V
Input voltage VIN, NTE12 types
15V
1. If components are required in tape and reel format suffix order code with -R, e.g. NTE0505MC-R.
2. Calculated using MIL-HDBK-217 FN2 calculation model with nominal input voltage at full load.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NTE.K03 Page 1 of 6
NTE Series
Isolated 1W Single Output SM DC/DC Converters
OUTPUT CHARACTERISTICS
Parameter
Rated power
Conditions
TA=-40°C to 85°C
Min.
Typ.
Max.
1.0
Units
W
Voltage set point accuracy
Line regulation
See tolerance envelope
High VIN to low VIN
1.0
10
1.2
14
%/%
%
10% load to rated load, 03XXMC, 0503MC, 0505MEC
10% load to rated load, 0505MC & 1205MC
10% load to rated load, 0506MC
10% load to rated load, 0509MC & 1209MC
10% load to rated load, 0512MC & 1212MC
10% load to rated load, 0515MC & 1215MC
BW=DC to 20MHz, 03XXMC, 0503MC, 0505MEC
BW=DC to 20MHz, 0505MC & 1205MC
BW=DC to 20MHz, 0506MC
12.8
9.2
8.3
6.8
6.3
40
15
10
Load regulation1
Ripple and noise
9.0
7.5
7.0
60
62
85
103
49
170
75
mV p-p
BW=DC to 20MHz, 0509MC & 1209MC
BW=DC to 20MHz, 0512MC & 1212MC
BW=DC to 20MHz, 0515MC & 1215MC
39
65
38
76
TEMPERATURE CHARACTERISTICS
Parameter
Specification
Storage
Conditions
All output types
Min.
-40
Typ.
Max.
85
Units
°C
-55
125
0305MC, 0309MC, 0315MC
25
30
43
40
0303MC, 0312MC, 0503MC, 0505MEC, 0509MC, 0512MC, 0515MC
0505MC, 1205MC
Case temperature rise above
ambient
1209MC, 1212MC, 1215MC
Cooling
Free air convection
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NTE series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specific agency approvals, such as the NTE series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NTE series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
TEMPERATURE DERATING GRAPH
1.5
85°C
1.0
0.5 Safe Operating Area
0
-40
100
150
0
50
Ambient Temperature (°C)
1. 12V input types have typically 3% less load regulation change.
www.murata-ps.com/support
KDC_NTE.K03 Page 2 of 6
NTE Series
Isolated 1W Single Output SM DC/DC Converters
TOLERANCE ENVELOPES
All other types.
+10%
3.3V output types.
+9%
+5%
+2.5%
+1%
VNOM
+1%
-7%
VNOM
-2.5%
-7%
-7.5%
-15%
100
75
Output Load Current (%)
100
10 25
50
75
Output Load Current (%)
10 25
50
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading.
RoHS COMPLIANCE, MSL AND PSL INFORMATION
This series is compatible with RoHS soldering systems and is also backward compatible with Sn/Pb soldering systems.
The NTE series has a process, moisture, and reflow sensitivity classification of MSL1 PSL R7F as defined in J-STD-020
and J-STD-075. This translates to: MSL1 = unlimited floor life, PSL R7F = Peak reflow temperature 245°C with a
limitation on the time above liquidus (217°C) which for this series is 60sec max. The pin termination finish on this product
series is Gold with a plating thickness of 0.05 microns minimum.
For further information please visit www.murata-ps.com/rohs
APPLICATION NOTES
Minimum load
The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in
an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%.
Capacitive loading and start up
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product
series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF.
Typical Start-Up Wave Form
Start-up time
μs
Start-up time
μs
NTE0303MC
NTE0305MC
NTE0309MC
NTE0312MC
NTE0315MC
NTE0503MC
NTE0505MC
NTE0505MEC
437
NTE0506MC
NTE0509MC
NTE0512MC
NTE0515MC
NTE1205MC
NTE1209MC
NTE1212MC
NTE1215MC
7200
3146
4960
7740
895
1359
3435
6590
7625
533
2150
3640
7180
1368
721
www.murata-ps.com/support
KDC_NTE.K03 Page 3 of 6
NTE Series
Isolated 1W Single Output SM DC/DC Converters
APPLICATION NOTES (continued)
Output Ripple Reduction
By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max.
Component selection
Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended.
The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter.
Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor
should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be
>20MHz.
L
DC
Power
Source
Load
C
DC
Inductor
SMD
Capacitor
L, μH
10
47
22
10
47
10
47
47
10
22
47
47
47
22
47
47
Through Hole
11R103C
11R103C
11R223C
11R103C
11R473C
11R103C
11R473C
11R473C
11R103C
11R223C
11R473C
11R473C
11R473C
11R223C
11R473C
11R473C
C, μF
4.7
4.7
2.2
1
NTE0303MC
NTE0305MC
NTE0309MC
NTE0312MC
NTE0315MC
NTE0503MC
NTE0505MC
NTE0505MEC
NTE0506MC
NTE0509MC
NTE0512MC
NTE0515MC
NTE1205MC
NTE1209MC
NTE1212MC
NTE1215MC
82103C
82473C
82223C
82103C
82473C
82103C
82473C
82473C
82103C
82223C
82473C
82473C
82473C
82223C
82473C
82473C
1
4.7
4.7
4.7
4.7
2.2
1
1
4.7
2.2
1
1
www.murata-ps.com/support
KDC_NTE.K03 Page 4 of 6
NTE Series
Isolated 1W Single Output SM DC/DC Converters
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS
12.70 (0.500)
7.62 (0.300)
Pin
1
Function
-VIN
DETAIL A
14
10
8
12
3
+VIN
NA
5
0.50 (0.020)
REFERENCE
PLANE
11.20 (0.441)
7.70 (0.303)
7
-VOUT
+VOUT
NA
10.40 (0.409)
NTE0505MC
P
8
XYYWW
10
12
14
1.50 (0.059)
1.20 (0.047)
1
3
5
7
°
5.00
NA
10 PINS
0.65 (0.026)
0.55 (0.022)
NA
2.54 (0.100)
0.2 (0.008)
S
2.10 (0.083)
DETAIL A
SEATING
NA - Not available for electrical connection.
6.60 (0.260) 6.35 (0.250)
5.95 (0.234) 5.85 (0.230)
S
PLANE
0.25 (0.010)
0.10 (0.004)
0.30 (0.012)
0.20 (0.008)
1.875 MAX
2.79 (0.110) MAX
0.1(0.004) S
All dimensions in mm 0.25mm (inches 0.01). All pins on a 2.54 (0.1) pitch and within 0.25 (0.01) of true position.
Weight: 1.21g
RECOMMENDED FOOTPRINT DETAILS
TUBE OUTLINE DIMENSIONS
0.60 0.15 (0.024 0.006)
7.62
(0.3)
2.10 (0.083)
2.00 (0.079)
9.70
(0.382)
14.35 (0.565)
9.40 (0.370)
2.54 (0.1)
6.70 (0.264)
1.00 (0.040) MIN
Unless otherwise stated all dimensions in mm 0.5mm (inches 0.02).
Tube length : 475 2.0 (18.70 0.07).
All pins on a 2.54mm pitch.
Unless otherwise stated all dimensions in mm (inches) 0.5mm.
Tube Quantity : 35
www.murata-ps.com/support
KDC_NTE.K03 Page 5 of 6
NTE Series
Isolated 1W Single Output SM DC/DC Converters
TAPE & REEL SPECIFICATIONS
REEL OUTLINE DIMENSIONS
TAPE OUTLINE DIMENSIONS
330
(12.99) MAX
13.20
(0.52)
0.60 (0.02) MAX
100
(3.94) MIN
Ø
+0.004 (+0.10)
-0.00 (-0.00)
1.50 (Ø0.06)
16.00 (0.63)
13.00 0.25
(0.51 0.009)
Ø
2.00
(0.08)
11.60
(0.46)
4.00
(0.16)
1.75(0.07)
6.60
(0.26)
11.50
(0.45)
24.00 0.30
(0.94 0.04)
REEL PACKAGING DETAILS
CARRIER TAPE START
100 (3.94) MIN
TRAILER SECTION
160 (6.30) MIN
GOODS ENCLOSURE
SECTION
Product Orientation
Pin 1, located nearest to
carrier drive sprocket.
LEADER SECTION
400 (15.75) MIN
Reel Quantity : 500
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2012 Murata Power Solutions, Inc.
www.murata-ps.com/support
KDC_NTE.K03 Page 6 of 6
相关型号:
NTE0312XMC
1W, FIXED INPUT, ISOLATED SINGLE OUTPUT SMD DC-DC CONVERTER 功率1W,定电压输入,隔离1500VDC,单输出,SMD贴片封装DC-DC电源模块转换器
MICRODC
NTE0315XMC
1W, FIXED INPUT, ISOLATED SINGLE OUTPUT SMD DC-DC CONVERTER 功率1W,定电压输入,隔离1500VDC,单输出,SMD贴片封装DC-DC电源模块转换器
MICRODC
NTE0503XMC
1W, FIXED INPUT, ISOLATED SINGLE OUTPUT SMD DC-DC CONVERTER 功率1W,定电压输入,隔离1500VDC,单输出,SMD贴片封装DC-DC电源模块转换器
MICRODC
©2020 ICPDF网 联系我们和版权申明