OKL2-T/20-W12 Series  
s
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
Typical unit  
FEATURES  
PRODUCT OVERVIEW  
The OKL2-T/20-W12 series are non-isolated  
The wide input range is 4.5 to 14Volts DC.  
The maximum output current is 20Amps. Based  
on fixed-frequency synchronous buck converter  
switching topology, the high power conversion  
efficient Point of Load (PoL) module features pro-  
grammable output voltage and On/Off control.  
These converters also include under voltage lock  
  
iLGA inspectable Land Grid Array  
point-of-Load (PoL) DC-DC power converters for  
embedded applications. The tiny form factor is  
configured on a Land Grid Array (LGA) assembly  
measuring only 1.3 x 0.53 x0.34 inches (33.02 x  
13.46 x 8.75 mm). Applications include powering  
CPUs, datacom/telecom systems, distributed bus  
  
4.5-14Vdc input voltage range  
  
Programmable output voltage from 0.69-5.5Vdc  
  
Drives 1000μF ceramic capacitive loads  
  
High power conversion efficiency at 94%  
  
Outstanding thermal derating performance  
architectures (DBA), programmable logic and mixed out (UVLO), output short circuit protection, over-  
voltage systems. current and over temperature protections.  
  
Over temperature and over current protection  
  
On/Off control and Power Good output  
  
RoHS-6 hazardous substance compliance  
  
Tracking operation/Synchronized function  
Connection Diagram  
+Vin  
+Vout  
tꢀ4XJUDIJOH  
tꢀ'JMUFST  
F1  
On/Off  
Control  
Controller  
tꢀ$VSSFOUꢀ4FOTF  
External  
DC  
Trim  
Power  
Source  
Reference and  
Error Amplifier  
Open = On  
Closed = Off  
(Positive  
On/Off)  
Common  
Common  
4FRVFODFꢁ5SBDLJOH  
Power Good  
Sync  
Figure 1. OKL2-T/20-W12  
Note: Murata Power Solutions strongly recommends an external input fuse, F1.  
See specifications.  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 1 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE  
Output  
R/N  
Input  
Dimensions  
Inches (mm)  
On/  
Off  
Logic  
Efficiency (%)  
Model Number  
Regulation (max.)  
Vout Iout (Amps, Power  
Vin nom.  
(Volts)  
Range Iin, no load Iin, full load  
(Volts) (mA) (Amps) ➁  
(mV p-p)  
Max. ➃  
(Volts) max.) (Watts)  
Line  
Load  
Min.  
91.0  
Typ.  
OKL2-T/20-W12P2-C  
OKL2-T/20-W12N2-C  
Pos.  
Neg.  
1.3 x 0.53 x 0.34  
(33.02 x 13.46 x 8.75)  
0.69-5.5  
20  
100  
35  
0.4% 0.3%  
12  
4.5-14  
75  
8.87  
94.0  
The output range is limited by Vin. See detailed specs.  
Use adequate ground plane and copper thickness adjacent to the converter.  
All specifications are at nominal line voltage, Vout=nominal (5V) and full  
load, +25°C. unless otherwise noted.  
Ripple and Noise (R/N) and no-load input current are shown at Vout=1.8V.  
See specs for details.  
Output capacitors are 188 μF ceramic. Input cap is 44 μF. See tailed  
specifications. I/O caps are necessary for our test equipment and may not  
be needed for your application.  
PART NUMBER STRUCTURE  
OK L 2 - T / 20 - W12 N2 - C  
Okami Non-isolated PoL  
iLGA Surface Mount, MSL Rating 2  
Sequence/tracking  
RoHS Hazardous  
Substance Compliance  
C = RoHS-6 (does not claim EU RoHS exemption  
Blank = Not Installed  
2 = installed  
7b – lead in solder)  
Trimmable Output  
Voltage Range  
0.69-5.5Vdc  
On/Off Logic  
P2 = Positive Logic  
N2 = Negative Logic  
Maximum Rated Output  
Current in Amps  
Input Voltage Range  
4.5-14Vdc  
Product Label  
Because of the small size of these products, the product label contains a  
character-reduced code to indicate the model number and manufacturing date  
code. Not all items on the label are always used. Please note that the label  
differs from the product photograph. Here is the layout of the label:  
Model Number  
OKL2-T/20-W12P2-C  
OKL2-T/20-W12N2-C  
Product Code  
L21120  
L20120  
The manufacturing date code is four characters:  
First character – Last digit of manufacturing year, example 2009  
Second character – Month code (1 through 9 = Jan-Sep;  
O, N, D = Oct, Nov, Dec)  
Third character – Day code (1 through 9 = 1 to 9, 10 = 0 and  
11 through 31 = A through Z)  
XXXXXX  
Product code  
Revision level  
Mfg.  
date  
code  
YMDX Rev.  
Figure 2. Label Artwork Layout  
Fourth character – Manufacturing information  
The label contains two rows of information:  
First row – Model number product code (see table)  
Second row – Manufacturing date code and revision level  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 2 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
FUNCTIONAL SPECIFICATIONS  
ABSOLUTE MAXIMUM RATINGS  
Input Voltage, Continuous  
Output Power  
Conditions (1)  
Full power operation  
Minimum  
Typical/Nominal  
Maximum  
15  
Units  
Vdc  
W
0
0
110  
Current-limited, no damage,  
short-circuit protected  
Output Current  
0
20  
A
On/Off Control  
Power Good Pin  
Synchronized Pin  
Sequence Pin  
Storage Temperature Range  
14  
6
12  
Vin max  
125  
Vdc  
Vdc  
Vdc  
Vdc  
˚C  
Vin = Zero (no power)  
-55  
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other  
than those listed in the Performance/Functional Specifications Table is not implied or recommended.  
INPUT  
Operating voltage range (7)  
Recommended External Fuse  
Turn On/Start-up threshold  
Undervoltage Shutdown  
Internal Filter Type  
See output voltage vs input voltage  
Fast blow  
4.5  
12  
14  
36  
4.5  
4.3  
Vdc  
A
Vdc  
Rising input voltage  
3.9  
3.7  
4.2  
4
C-TYPE  
Input current  
Full Load Conditions  
Low Line  
Inrush Transient  
Short Circuit Input Current  
No Load Input Current  
No Load Input Current  
Shut-Down Mode Input Current  
Reflected (back) ripple current (2)  
GENERAL and SAFETY  
Vin = nominal (5Vo set)  
Vin @ min, 5 Vout  
8.87  
15.12  
TBD  
TBD  
75  
35  
1
TBD  
9.29  
15.85  
A
A
A2-Sec.  
mA  
5Vout, Iout @ 0  
1V, Iout @ 0  
150  
70  
mA  
mA  
mA, pk-pk  
Measured at input with specified filter  
@ Vin nom, 5Vout  
@ Vin min=8Vin, 5Vout  
@ Vin nom, 3.3Vout  
91  
91.5  
89  
94  
94.5  
92  
EFFICIENCY (12Vin @ 12A load current)  
%
@ Vin nom, 2.5Vout  
90  
@Vin nom, 1.8Vout  
83.5  
88  
Certified to UL-60950-1, CSA-C22.2  
No.60950-1, IEC/60950-1, 2nd edition  
(pending)  
Safety  
Yes  
Per Telcordia SR332, issue 1 class 3, ground  
fixed, Tambient=+25˚C  
Calculated MTBF (4a)  
8,068,510  
4,514,048  
Hours  
Hours  
Calculated MTBF (4b)  
Per Mil-HDBK-217N2 Method  
DYNAMIC CHARACTERISTICS  
Fixed Switching Frequency  
Synchronization frequency range  
High level input voltage  
Low level input voltage  
Input currrent SYNC pin  
Minimun pulse width, SYNC  
Minimum pulse set-up/hold time  
Startup Time  
400  
KHz  
KHz  
Vdc  
Vdc  
mA  
nS  
nS  
mS  
mS  
420  
3
0
600  
12  
0.8  
1
VSYNC = 3.0V  
250  
250  
SYNC pin (note 15)  
Power On to Vout regulated  
Remote ON to to Vout regulated  
50-100-50% load step, settling time to within  
2% of Vout di/dt =1 A/μSec  
same as above  
6
6
Startup Time  
Dynamic Load Response  
100  
200  
μSec  
mV  
Dynamic Load Peak Deviation  
FEATURES and OPTIONS  
Remote On/Off Control (5)  
“N” suffix  
Negative Logic, ON state  
Negative Logic, OFF state  
Control Current  
Pin open=ON  
open collector/drain  
Pin open=ON  
0
2
0.7  
+Vin-max  
3
V
V
mA  
“P” suffix  
Positive Logic, ON state  
Positive Logic, OFF state  
Control Current  
+Vin-0.8V  
0
Vin-max  
2.5  
3
500  
V
V
mA  
mV  
open collector/drain  
Remote Sense  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 3 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
FUNCTIONAL SPECIFICATIONS (CONT.)  
FEATURES and OPTIONS, CONT.  
Tracking/Sequencing(optional)  
Slew Rate  
Tracking Accuracy  
Tracking Accuracy  
Conditions (1)  
Minimum  
Typical/Nominal  
Maximum  
Units  
TBD  
V/mS  
mV  
mV  
Rising input (0.5V/ms)  
Falling input(0.5V/ms)  
TBD  
TBD  
Power Good Option  
PGOOD, Open Drain Configuration, Sinking:  
Vout window for PGOOD: True  
Vout window for PGOOD: False  
OUTPUT  
-10%  
0
10%  
110  
Vset  
Vdc  
0.05  
100  
Total Output Power  
W
Voltage  
Nominal Output Voltage Range (13)  
Setting Accuracy  
Output Voltage Overshoot-Startup  
Current  
See trim formula  
At 50% load  
0.69  
-1.5  
5.5  
1.5  
3
Vdc  
% of Vnom.  
% Vo set  
Output Current Range  
Minimum Load  
Current Limit Inception (6)  
Short Circuit  
0
20  
No minimum load  
32  
20  
A
A
98% of Vnom., after warmup  
20.2  
Hiccup technique, autorecovery within 1%  
of Vout  
Short Circuit Current (17)  
0.02  
A
Short Circuit Duration (remove short for  
recovery)  
Short circuit protection method  
Regulation (10)  
Output shorted to ground, no damage  
Current limiting  
Continuous  
Total Regulation Band  
Line Regulation  
Load Regulation  
-2.5  
188  
Vo set  
2.5  
0.4  
0.3  
100  
80  
% Vo set  
%
%
Vin=min. to max. Vout=nom.  
Iout=min. to max.  
5Vo, 12Vin  
45  
35  
35  
30  
0.02  
3.3Vo, 12Vin  
1.8Vo, 12Vin  
0.69Vo, 7Vin  
At all outputs  
Ripple and Noise (8)  
mV pk-pk  
80  
70  
Temperature Coefficient  
% of Vnom./°C  
ꢀF  
Low ESR; >0.001, <0.01 ohm  
ESR > 0.01 ohm  
1000  
10000  
Maximum Capacitive Loading (14)  
MECHANICAL  
Outline Dimensions  
1.3 x 0.53 x 0.34  
33.02 x 13.46 x 8.75  
Inches  
mm  
Weight  
0.2  
5.4  
Ounces  
Grams  
ENVIRONMENTAL  
full power, all output voltages, see derating  
curves  
Operating Ambient Temperature Range (9)  
-40  
-55  
85  
˚C  
Storage Temperature  
Thermal Protection/Shutdown  
RoHS rating  
Vin = Zero (no power)  
Measured in center  
125  
˚C  
˚C  
TBD  
RoHS-6  
Notes  
(1) Specifications are typical at +25 °C, Vin = nominal (+12V), Vout = nominal (+5V), full load, external caps and  
natural convection unless otherwise indicated. Extended tests at full power must supply substantial forced  
airflow. All models are tested and specified with external 188ꢀF ceramic output capacitors and a 44 ꢀF external  
input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate our test  
equipment and may not be required to achieve specified performance in your applications. However, Murata  
Power Solutions recommends installation of these capacitors. All models are stable and regulate within spec  
under no-load conditions.  
(4b) Mean Time Before Failure is calculated using the MIL-HDBK-217N2 method, ground benign, +25oC., full output  
load, natural convection.  
(5) The On/Off Control Input should use either a switch or an open collector/open drain transistor referenced to  
-Input Common. A logic gate may also be used by applying appropriate external voltages which do not exceed  
+Vin.  
(6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting.  
(7) Please observe the voltage input and output specifications in the voltage range graph.  
(2) Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is Cin = 2 x  
100 ꢀF ceramic, Cbus = 1000 ꢀF electrolytic, Lbus = 1 ꢀH.  
(8) Output noise may be further reduced by adding an external filter. At zero output current, the output may contain  
low frequency components which exceed the ripple specification. The output may be operated indefinitely with  
no load.  
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher  
temperatures and/or lower airflow, the DC-DC converter will tolerate brief full current outputs if the total RMS  
current over time does not exceed the Derating curve.  
(9) All models are fully operational and meet published specifications, including “cold start” at –40˚ C.  
(10) Regulation specifications describe the deviation as the line input voltage or output load current is varied from a  
nominal midpoint value to either extreme.  
(4a) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fixed  
conditions, Tpcboard = +25 ˚C, full output load, natural air convection.  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 4 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
Notes, cont.  
(11) Other input or output voltage ranges will be reviewed under scheduled quantity special order.  
(12) Maximum PC board temperature is measured with the sensor in the center of the converter.  
(13) Do not exceed maximum power specifications when adjusting the output trim.  
(15) Do not allow the input voltage to degrade lower than the input undervoltage shutdown voltage at all times.  
Otherwise, you risk having the converter turn off. The undervoltage shutdown is not latching and will attempt to  
recover when the input is brought back into normal operating range.  
(16) The outputs are not intended to sink appreciable reverse current.  
(14) The maximum output capacitive loads depend on the the Equivalent Series Resistance (ESR) of the external  
output capacitor and, to a lesser extent, the distance and series impedance to the load. Larger caps will reduce  
output noise but may change the transient response. Newer ceramic caps with very low ESR may require lower  
capacitor values to avoid instability. Thoroughly test your capacitors in the application. Please refer to the Output  
Capacitive Load Technical Note.  
(17) “Hiccup” overcurrent operation repeatedly attempts to restart the converter with a brief, full-current output. If the  
overcurrent condition still exists, the restart current will be removed and then tried again. This short current pulse  
prevents overheating and damaging the converter. Once the fault is removed, the converter immediately recovers  
normal operation.  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 5 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
OKL2-T/20-W12 PERFORMANCE DATA AND OSCILLOGRAMS  
Efficiency vs. Line Voltage and Load Current @Ta = +25 °C (Vout = 5V)  
100  
Maximum Current Temperature Derating at Sea Level (Vin=12V, Vout=5.0V)  
22  
20  
18  
16  
14  
12  
10  
8
95  
VIN = 8V  
VIN = 12V  
VIN = 14V  
90  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
85  
6
80  
75  
4
2
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
0
4
8
12  
16  
20  
Ambient Temperature (°C)  
Load Current (Amps)  
On/Off Enable Delay (Vin=12V, Vout=5.0V, Iout=20A, Cload=188μF) Trace2=Enable,  
5V/div Trace1=Vout,2V/div  
Output Ripple and Noise (Vin=12V, Vout=5.0V, Iout=20A, Cload=188μF,  
ScopeBW=20MHz) Trace1=Vout,10mV/div(AC)  
Step Load Transient Response (Vin=12V, Vout=5.0V, Cload=188μF, Iout=10A to 20A)  
Trace 1=Vout, 100 mV/div(AC), Trace 4=Iout, 10A/div.  
Step Load Transient Response (Vin=12V, Vout=5.0V, Cload=188μF, Iout=20A to 10A)  
Trace 1=Vout, 100 mV/div(AC), Trace 4=Iout, 10A/div.  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 6 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
OKL2-T/20-W12 PERFORMANCE DATA AND OSCILLOGRAMS  
Efficiency vs. Line Voltage and Load Current @Ta = +25 °C (Vout = 3.3V)  
100  
Maximum Current Temperature Derating at Sea Level (Vin=12V, Vout=3.3V)  
22  
20  
18  
16  
14  
12  
10  
8
95  
VIN = 4.5V  
VIN = 12V  
VIN = 14V  
90  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
85  
6
80  
75  
4
2
0
20  
30  
40  
50  
60  
70  
80  
90  
0
4
8
12  
16  
20  
Ambient Temperature (°C)  
Load Current (Amps)  
On/Off Enable Delay (Vin=12V, Vout=3.3V, Iout=20A, Cload=188μF) Trace2=Enable,  
5V/div Trace1=Vout,1V/div  
Output Ripple and Noise (Vin=12V, Vout=3.3V, Iout=20A, Cload=188μF,  
ScopeBW=20MHz) Trace1=Vout,10mV/div(AC)  
Step Load Transient Response (Vin=12V, Vout=3.3V, Cload=188μF, Iout=10A to 20A)  
Trace 1=Vout, 100 mV/div(AC), Trace 4=Iout, 10A/div.  
Step Load Transient Response (Vin=12V, Vout=3.3V, Cload=188μF, Iout=20A to 10A)  
Trace 1=Vout, 100 mV/div(AC), Trace 4=Iout, 10A/div.  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 7 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
OKL2-T/20-W12 PERFORMANCE DATA AND OSCILLOGRAMS  
Efficiency vs. Line Voltage and Load Current @Ta = +25 °C (Vout = 2.5V)  
100  
Maximum Current Temperature Derating at Sea Level (Vin=12V, Vout=2.5V)  
22  
20  
18  
16  
14  
12  
10  
8
95  
90  
VIN = 4.5V  
VIN = 12V  
VIN = 14V  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
85  
6
80  
75  
4
2
0
20  
30  
40  
50  
60  
70  
80  
90  
0
4
8
12  
16  
20  
Ambient Temperature (°C)  
Load Current (Amps)  
On/Off Enable Delay (Vin=12V, Vout=2.5V, Iout=20A, Cload=188μF) Trace2=Enable,  
5V/div Trace1=Vout,1V/div  
Output Ripple and Noise (Vin=12V, Vout=2.5V, Iout=20A, Cload=188μF,  
ScopeBW=20MHz) Trace1=Vout,10mV/div(AC)  
Step Load Transient Response (Vin=12V, Vout=2.5V, Cload=188μF, Iout=10A to 20A)  
Trace 1=Vout, 100 mV/div(AC), Trace 4=Iout, 10A/div.  
Step Load Transient Response (Vin=12V, Vout=2.5V, Cload=188μF, Iout=20A to 10A)  
Trace 1=Vout, 100 mV/div(AC), Trace 4=Iout, 10A/div.  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 8 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
OKL2-T/20-W12 PERFORMANCE DATA AND OSCILLOGRAMS  
Efficiency vs. Line Voltage and Load Current @Ta = +25 °C (Vout = 1.8V)  
100  
Maximum Current Temperature Derating at Sea Level (Vin=12V, Vout=1.8V)  
22  
20  
18  
16  
14  
12  
10  
8
95  
90  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
VIN = 4.5V  
VIN = 12V  
85  
VIN = 14V  
6
80  
4
2
0
75  
20  
30  
40  
50  
60  
70  
80  
90  
0
4
8
12  
16  
20  
Ambient Temperature (°C)  
Load Current (Amps)  
On/Off Enable Delay (Vin=12V, Vout=1.8V, Iout=20A, Cload=188μF) Trace2=Enable,  
5V/div Trace1=Vout,500mV/div  
Output Ripple and Noise (Vin=12V, Vout=1.8V, Iout=20A, Cload=188μF,  
ScopeBW=20MHz) Trace1=Vout,10mV/div(AC)  
Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=188μF, Iout=10A to 20A)  
Trace 1=Vout, 100 mV/div(AC), Trace 4=Iout, 10A/div.  
Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=188μF, Iout=20A to 10A)  
Trace 1=Vout, 100 mV/div(AC), Trace 4=Iout, 10A/div.  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 9 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
OKL2-T/20-W12 PERFORMANCE DATA AND OSCILLOGRAMS  
Efficiency vs. Line Voltage and Load Current @Ta = +25 °C (Vout = 1.2V)  
95  
Maximum Current Temperature Derating at Sea Level (Vin=12V, Vout=1.2V)  
22  
20  
18  
16  
14  
12  
10  
8
90  
85  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
VIN = 4.5V  
VIN = 10.8V  
VIN = 12V  
80  
75  
70  
6
4
2
0
20  
30  
40  
50  
60  
70  
80  
90  
0
4
8
12  
16  
20  
Ambient Temperature (°C)  
Load Current (Amps)  
On/Off Enable Delay (Vin=12V, Vout=1.2V, Iout=20A, Cload=188μF) Trace2=Enable,  
5V/div Trace1=Vout,500mV/div  
Output Ripple and Noise (Vin=12V, Vout=1.2V, Iout=20A, Cload=188μF,  
ScopeBW=20MHz) Trace1=Vout,10mV/div(AC)  
Step Load Transient Response (Vin=12V, Vout=1.2V, Cload=188μF, Iout=10A to 20A)  
Trace 1=Vout, 100 mV/div(AC), Trace 4=Iout, 10A/div.  
Step Load Transient Response (Vin=12V, Vout=1.2V, Cload=188μF, Iout=20A to 10A)  
Trace 1=Vout, 100 mV/div(AC), Trace 4=Iout, 10A/div.  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 10 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
OKL2-T/20-W12 PERFORMANCE DATA AND OSCILLOGRAMS  
Efficiency vs. Line Voltage and Load Current @Ta = +25 °C (Vout = 0.69V)  
95  
Maximum Current Temperature Derating at Sea Level (Vin=7V, Vout=0.69V)  
22  
20  
18  
16  
14  
12  
10  
8
90  
85  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
VIN = 4.5V  
80  
VIN = 5V  
VIN = 7V  
6
75  
4
2
0
70  
20  
30  
40  
50  
60  
70  
80  
90  
0
4
8
12  
16  
20  
Ambient Temperature (°C)  
Load Current (Amps)  
On/Off Enable Delay (Vin=5.5V, Vout=0.69V, Iout=20A, Cload=188μF) Trace2=Enable,  
5v/div, Trace1=Vout,200mV/div  
Output Ripple and Noise (Vin=7V, Vout=0.69V, Iout=20A, Cload=188μF,  
ScopeBW=20MHz) Trace1=Vout,10mV(AC)  
Step Load Transient Response (Vin=7V, Vout=0.69V, Cload=188μF, Iout=10A to 20A)  
Trace 1=Vout, 100 mV/div(AC), Trace 4=Iout, 10A/div.  
Step Load Transient Response (Vin=7V, Vout=0.69V, Cload=188μF, Iout=20A to 10A)  
Trace 1=Vout, 100 mV/div(AC), Trace 4=Iout, 10A/div.  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 11 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
MECHANICAL SPECIFICATIONS  
8
1
1
8
33.02  
31.80  
7
6
24.26  
19.43  
7
6
5
4
L*****  
①②③④  
1.78×3.10×10PLACES  
9
5
4
3
14.60  
9.78  
9
Figure 3. OKL2-T/20-W12 Mechanical Outline  
4.95  
3
1.90  
Y
1
0
2
2
10  
X
TOP VIEW  
0
UNIT[mm]  
[Tolerances 0.25mm]  
BOTTOM VIEW  
8.75  
MAX  
SIDE VIEW  
INPUT/OUTPUT CONNECTIONS  
Pin  
1
2
Function  
On/Off Control*  
VIN  
3
4
Sequence/Tracking  
Ground  
5
VOUT  
Dimensions are in inches (mm shown for ref. only).  
6
Trim  
Third Angle Projection  
7
8
9
10  
+Sense (VOUT)  
-Sense (Ground)  
Power Good Out  
Syncronization  
Tolerances (unless otherwise specified):  
.XX 0.02 (0.5)  
.XXX 0.010 (0.25)  
Angles 1˚  
*The Remote On/Off can be provided with  
either positive (P suffix) or negative (N suffix)  
logic.  
Components are shown for reference only.  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 12 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
RECOMMENDED LAYOUT  
TOP VIEW  
Unit:mm  
1.22  
7.54  
4.83  
4.83  
4.82  
4.83  
4.95  
8 PLACES  
7
6
5
4
3
(B)  
(B)  
(B)  
(B)  
(B)  
(B)  
10  
(A)  
(A)  
8
(B)  
2
9
(B)  
1
2 PLACES  
1.90  
Product outline  
SOLDER PAD NOTES:  
[1] To avoid incorrect contacts with exposed vias and plated through holes on the bottom of the  
converter, do not have any exposed copper in the center area of the host PC board (see drawing).  
Except for connections to the pads, keep all external circuits away from the board edges.  
[2] Do not connect any additional components between the Trim pin and Vout or between the Trim  
and Sense pins. Use only the specified connections.  
Dimensions are in inches (mm shown for ref. only).  
Third Angle Projection  
Tolerances (unless otherwise specified):  
.XX 0.02 (0.5)  
.XXX 0.010 (0.25)  
Angles 1˚  
Components are shown for reference only.  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 13 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
TAPE AND REEL INFORMATION (MSL RATING 2)  
Tape Detail  
Vacuum Pickup  
Point in Center  
Pulling direction  
A-A' SECTION  
Reel  
Reel Information (200 units per reel)  
Reel Information (200 units per reel)  
Key Description  
Length (mm)  
A
B
C
Tape trailer (no modules)  
240 40  
Pocket tape length before modules  
Cover tape length before pocket tape  
240 60  
240 40  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 14 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
TECHNICAL NOTES  
Output Voltage Adustment  
capacitor inputs), the converter shuts off and then restarts as the external  
capacitor recharges. Such situations could oscillate. To prevent this, make  
sure the operating input voltage is well above the UV Shutdown voltage AT  
ALL TIMES.  
The output voltage may be adjusted over a limited range by connecting an  
external trim resistor (Rtrim) between the Trim pin and Ground. The Rtrim  
resistor must be a 1/10 Watt precision metal film type, 0.5% accuracy or  
better with low temperature coefficient, 100 ppm/degC. or better. Mount  
the resistor close to the converter with very short leads or use a surface  
mount trim resistor.  
Start-Up Time  
Assuming that the output current is set at the rated maximum, the Vin to  
Vout Start-Up Time (see Specifications) is the time interval between the  
point when the ramping input voltage crosses the Start-Up Threshold and  
the fully loaded regulated output voltage enters and remains within its  
specified accuracy band. Actual measured times will vary with input source  
impedance, external input capacitance, input voltage slew rate and final  
value of the input voltage as it appears at the converter.  
In the table below, the calculated resistance is given. Do not exceed the  
specified limits of the output voltage or the converter’s maximum power  
rating when applying these resistors. Also, avoid high noise at the Trim  
input. However, to prevent instability, you should never connect any capaci-  
tors to Trim.  
OKL2-T/20-W12  
These converters include a soft start circuit to moderate the duty cycle of  
its PWM controller at power up, thereby limiting the input inrush current.  
The On/Off Remote Control interval from On command to Vout regulated  
Output Voltage  
5.0 V  
Calculated Rtrim (KΩ)  
1.60  
3.3 V  
2.64  
assumes that the converter already has its input voltage stabilized above  
the Start-Up Threshold before the On command. The interval is measured  
from the On command until the output enters and remains within its  
specified accuracy band. The specification assumes that the output is fully  
loaded at maximum rated current. Similar conditions apply to the On to Vout  
regulated specification such as external load capacitance and soft start  
circuitry.  
2.5 V  
3.81  
2.0 V  
5.27  
1.8 V  
6.22  
1.5 V  
8.52  
1.2 V  
13.53  
22.26  
∞ (open)  
1.0 V  
Recommended Input Filtering  
0.69 V  
The user must assure that the input source has low AC impedance to  
provide dynamic stability and that the input supply has little or no inductive  
content, including long distributed wiring to a remote power supply. The  
converter will operate with no additional external capacitance if these  
conditions are met.  
Resistor Trim Equation, OKL2-T/20-W12 models:  
6.9  
VOUT – 0.69  
_________  
RTRIM (kΩ) =  
For best performance, we recommend installing a low-ESR capacitor  
immediately adjacent to the converter’s input terminals. The capacitor  
should be a ceramic type such as the Murata GRM32 series or a poly-  
mer type. Initial suggested capacitor values are 44 μF, rated at twice the  
expected maximum input voltage. Make sure that the input terminals do  
not go below the under voltage shutdown voltage at all times. More input  
bulk capacitance may be added in parallel (either electrolytic or tantalum)  
if needed.  
Input Fusing  
Certain applications and/or safety agencies may require fuses at the inputs  
of power conversion components. Fuses should also be used when there  
is the possibility of sustained input voltage reversal which is not current  
limited. For greatest safety, we recommend a fast blow fuse installed in the  
ungrounded input supply line.  
The installer must observe all relevant safety standards and regulations.  
For safety agency approvals, install the converter in compliance with the  
end-user safety standard.  
Recommended Output Filtering  
The converter will achieve its rated output ripple and noise with no  
additional external capacitor. However, the user may install more exter-  
nal output capacitance to reduce the ripple even further or for improved  
dynamic response. Again, use low-ESR ceramic (Murata GRM32 series) or  
polymer capacitors. Initial values of 188 μF may be tried, either single or  
multiple capacitors in parallel. Mount these close to the converter. Measure  
the output ripple under your load conditions.  
Use only as much capacitance as required to achieve your ripple and noise  
objectives. Excessive capacitance can make step load recovery sluggish  
or possibly introduce instability. Do not exceed the maximum rated output  
capacitance listed in the specifications.  
Input Under-Voltage Shutdown and Start-Up Threshold  
Under normal start-up conditions, converters will not begin to regulate  
properly until the ramping-up input voltage exceeds and remains at the  
Start-Up Threshold Voltage (see Specifications). Once operating, convert-  
ers will not turn off until the input voltage drops below the Under-Voltage  
Shutdown Limit. Subsequent restart will not occur until the input voltage  
rises again above the Start-Up Threshold. This built-in hysteresis prevents  
any unstable on/off operation at a single input voltage.  
Users should be aware however of input sources near the Under-Voltage  
Shutdown whose voltage decays as input current is consumed (such as  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 15 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
Input Ripple Current and Output Noise  
Temperature Derating Curves  
All models in this converter series are tested and specified for input  
reflected ripple current and output noise using designated external input/  
output components, circuits and layout as shown in the figures below. The  
Cbus and Lbus components simulate a typical DC voltage bus. Please note  
that the values of Cin, Lbus and Cbus will vary according to the specific  
converter model.  
The graphs in this data sheet illustrate typical operation under a variety of  
conditions. The derating curves show the maximum continuous ambient air  
temperature and decreasing maximum output current which is accept-  
able under increasing forced airflow measured in Linear Feet per Minute  
(“LFM”). Note that these are AVERAGE measurements. The converter will  
accept brief increases in current or reduced airflow as long as the average  
is not exceeded.  
Note that the temperatures are of the ambient airflow, not the converter  
itself which is obviously running at higher temperature than the outside  
air. Also note that very low flow rates (below about 25 LFM) are similar to  
“natural convection,” that is, not using fan-forced airflow. Murata makes  
Characterization measurements in a closed cycle wind tunnel with cali-  
brated airflow. We use both thermocouples and an infrared camera system  
to observe thermal performance.  
TO  
CURRENT  
PROBE  
OSCILLOSCOPE  
+VIN  
-VIN  
L
BUS  
+
+
VIN  
C
BUS  
CIN  
CAUTION: These graphs are all collected at slightly above Sea Level  
altitude. Be sure to reduce the derating for higher density altitude.  
C
IN = 2 x 100μF, ESR < 700mꢁ @ 100kHz  
BUS = 1000μF, ESR < 100mꢁ @ 100kHz  
Output Voltage Sequencing  
C
The OKL modules include a sequencing feature that enables users to  
implement various types of output voltage sequencing in their applications.  
This is accomplished via an additional sequencing pin. When not using the  
sequencing feature, either tie the sequence pin to Vin or leave it uncon-  
nected.  
LBUS = 1μH  
Figure 4. Measuring Input Ripple Current  
When an analog voltage is applied to the sequence pin, the output  
voltage tracks this voltage until the output reaches the set-point voltage.  
The final value of the sequence voltage must be set higher than the set-  
point voltage of the module. The output voltage follows the voltage on the  
sequence pin on a one-to-one volt basis. By connecting multiple modules  
together, multiple modules can track their output voltages to the voltage  
applied on the sequence pin.  
+VOUT  
-VOUT  
RLOAD  
SCOPE  
Cext  
For proper voltage sequencing, first, input voltage is applied to the  
module. The On/Off pin of the module is left unconnected (or tied to GND  
for negative logic modules or tied to Vin for positive logic modules) so that  
the module is ON by default. After applying input voltage to the module,  
a minimum 10msec delay is required before applying voltage on the  
sequence pin. During this time, a voltage of 50mV ( 20 mV) is maintained  
on the sequence pin. This delay gives the module enough time to complete  
its internal powerup soft-start cycle. During the delay time, the sequence  
pin should be held close to ground (nominally 50mV 20 mV). This is re-  
quired to keep the internal opamp out of saturation thus preventing output  
overshoot during the start of the sequencing ramp. By selecting resistor R1  
according to the following equation  
Figure 5. Measuring Output Ripple and Noise (PARD)  
The capacitor Cext value is found on the electrical data page.  
Minimum Output Loading Requirements  
All models regulate within specification and are stable under no load to full  
load conditions. Operation under no load might, however, slightly increase  
output ripple and noise.  
Thermal Shutdown  
23500  
R1 = ———— ohms,  
Vin – 0.05  
To prevent many over temperature problems and damage, these converters  
include thermal shutdown circuitry. If environmental conditions cause the  
temperature of the DC-DCs to rise above the Operating Temperature Range  
up to the shutdown temperature, an on-board electronic temperature  
sensor will power down the unit. When the temperature decreases below  
the turn-on threshold, the converter will automatically restart.  
the voltage at the sequencing pin will be 50mV when the sequencing  
signal is at zero. See figure 6 for R1 connection for the sequencing signal to  
the SEQ pin.  
CAUTION: If you operate too close to the thermal limits, the converter  
may shut down suddenly without warning. Be sure to thoroughly test your  
application to avoid unplanned thermal shutdown.  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 16 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
Output Current Limiting  
The “hiccup” system differs from older latching short circuit systems  
because you do not have to power down the converter to make it restart.  
The system will automatically restore operation as soon as the short circuit  
condition is removed.  
Current limiting inception is defined as the point at which full power falls  
below the rated tolerance. See the Performance/Functional Specifica-  
tions. Note particularly that the output current may briefly rise above its  
rated value in normal operation as long as the average output power is  
not exceeded. This enhances reliability and continued operation of your  
application. If the output current is too high, the converter will enter the  
short circuit condition.  
Remote On/Off Control  
The OKL Series power modules can be specified with either a positive or nega-  
tive logic type. See Figures 6 and 7 for On/Off circuit control. In the positive logic  
on/off option the unit turns on during a logic high on the On/Off pin and turns off  
during a logic low. In a negative logic on/off option, the unit turns off during logic  
high and on during logic low. The On/Off signal should always be reference to  
ground. For positive or negative option, leaving then On/Off pin disconnected  
will turn the unit on when input voltage is present.  
Output Short Circuit Condition  
When a converter is in current-limit mode, the output voltage will drop  
as the output current demand increases. If the output voltage drops too  
low (approximately 98% of nominal output voltage for most models), the  
magnetically coupled voltage used to develop primary side voltages will  
also drop, thereby shutting down the PWM controller. Following a time-out  
period, the PWM will restart, causing the output voltage to begin ramping  
up to its appropriate value. If the short-circuit condition persists, another  
shutdown cycle will initiate. This rapid on/off cycling is called “hiccup  
mode”. The hiccup cycling reduces the average output current, thereby  
preventing excessive internal temperatures and/or component damage. A  
short circuit can be tolerated indefinitely.  
Positive—Units are enabled when the on/off pin is left open or is pulled  
high to +Vin. The On/Off circuit control is shown in figure 6. When the  
external transistor Q1 is in the off state, the internal PWM enable pin is pull  
high causing the unit to turn on. When Q1 is turn on, the On/Off pin is pulled  
low and the units is off. Rp should be around 20K ohms.  
Negative—Units are enabled when the ON/Off is open or brought to  
within a low voltage (see specifications) with respect to –Vin. The unit is off  
when the ON/Off is pulled high with respect to –Vin (see specifications). The  
On/Off circuitry is shown in figure 7. The On/Off pin should be pulled high  
with an external pull-up resistor (20K ohms). When Q1 is in the off state,  
the On/Off pin is pulled high, transistor Q3 is turn on and the unit is off. To  
turn on the unit, Q1 is turn on, pulling the On/Off pin low and turning Q3 off  
resulting on the unit being on.  
OKL P Module  
+Vin  
Rp  
+Vin  
E
Dynamic control of the On/Off function should be able to sink the speci-  
fied signal current when brought low and withstand appropriate voltage  
when brought high. Be aware too that there is a finite time in milliseconds  
(see specifications) between the time of On/Off Control activation and  
stable, regulated output. This time will vary slightly with output load type  
and current and input conditions.  
R1  
On/Off  
PWM  
Q1  
Output Capacitive Load  
GND  
GND  
These converters do not require external capacitance added to achieve  
rated specifications. Users should only consider adding capacitance to  
reduce switching noise and/or to handle spike current load steps. Install  
only enough capacitance to achieve noise objectives. Excess external  
capacitance may cause regulation problems, degraded transient response  
and possible oscillation or instability.  
BOM Rp 20K  
BOM Q1 Q SMT MOS P 30V  
Figure 6. On/Off Circuit Control for Using Positive On/Off Logic  
OKL N Module  
Synchronization  
These converters can be synchronized using an external signal.  
+Vin  
Rp  
+Vin  
PWM  
GND  
E
Details of the SYNC signal are provided in the Performance and Func-  
tional Specifications table.  
On/Off  
Q3  
If the synchronization function is not being used, leave the SYNC pin  
floating.  
Q1  
When synchronization function is used, output ripple may increase on  
some operating conditions. Please check the proper operation of this device  
with the peripheral circuits on your system.  
GND  
GND  
BOM Rp 20K  
BOM Q1 Q SMT MOS P 30V  
Figure 7. On/Off Circuit Control for Using Negative On/Off Logic  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 17 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
Voltage Range Graph  
Please observe the limits below for voltage input and output ranges. These  
limits apply at all output currents (Ta = 25°C).  
16  
14  
12  
15  
14  
13  
12  
11  
10  
9
Vin=14V / Vout=1V  
10  
8
Vin=4.5V / Vout=3.3V  
6
without Sync (400kHz)  
Sync 420kHz  
4
8
Sync 520kHz  
Upper Limit  
Lower Limit  
2
7
Sync 600kHz  
6
0
0
1
2
3
4
5
6
0.6  
0.7  
0.8  
0.9  
1
1.1  
1.2  
1.3  
1.4  
1.5  
Output Voltage (V)  
Output Voltage (V)  
Figure 8. Voltage Range Graph  
Figure 9 Voltage Range Graph (range expansion)  
Soldering Guidelines  
Recommended Lead-free Solder Reflow Profile  
Murata Power Solutions recommends the specifications below when installing these  
converters. These specifications vary depending on the solder type. Exceeding these  
Peak Temp.  
235-260° C  
250  
specifications may cause damage to the product. Your production environment may differ  
200  
therefore please thoroughly review these guidelines with your process engineers.  
Reflow Solder Operations for surface-mount products (SMT)  
For Sn/Ag/Cu based solders:  
Reflow Zone  
150  
100  
50  
Soaking Zone  
120 sec max  
time above 217° C  
45-75 sec  
Preheat Temperature  
Time over Liquidus  
Less than 1 ºC. per second  
45 to 75 seconds  
<1.5° C/sec  
High trace = normal upper limit  
Low trace = normal lower limit  
Preheating Zone  
240 sec max  
Maximum Peak Temperature  
Cooling Rate  
260 ºC.  
Less than 3 ºC. per second  
0
For Sn/Pb based solders:  
Preheat Temperature  
Time over Liquidus  
0
30  
60  
90  
120  
150  
Time (sec)  
180  
210  
240  
270  
300  
Less than 1 ºC. per second  
60 to 75 seconds  
CAUTION: Do not reflow the DC-DC converter as follows, because the  
DC-DC converter may fall from the substrate during reflowing.  
Maximum Peak Temperature  
Cooling Rate  
235 ºC.  
Less than 3 ºC. per second  
DC-DC Converter  
Substrate  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 18 of 19  
OKL2-T/20-W12 Series  
Programmable Output 20-Amp iLGA SMT PoL  
DC-DC Converter Series  
Vertical Wind Tunnel  
Murata Power Solutions employs a computer controlled  
custom-designed closed loop vertical wind tunnel, infrared  
video camera system, and test instrumentation for accurate  
airflow and heat dissipation analysis of power products.  
The system includes a precision low flow-rate anemometer,  
variable speed fan, power supply input and load controls,  
temperature gauges, and adjustable heating element.  
IR Transparent  
optical window  
Variable  
speed fan  
Unit under  
test (UUT)  
The IR camera monitors the thermal performance of the  
Unit Under Test (UUT) under static steady-state conditions. A  
special optical port is used which is transparent to infrared  
wavelengths.  
IR Video  
Camera  
Both through-hole and surface mount converters are  
soldered down to a 10" x 10" host carrier board for realistic  
heat absorption and spreading. Both longitudinal and trans-  
verse airflow studies are possible by rotation of this carrier  
board since there are often significant differences in the heat  
dissipation in the two airflow directions. The combination of  
adjustable airflow, adjustable ambient heat, and adjustable  
Input/Output currents and voltages mean that a very wide  
range of measurement conditions can be studied.  
Heating  
element  
Precision  
low-rate  
anemometer  
3” below UUT  
The collimator reduces the amount of turbulence adjacent  
to the UUT by minimizing airflow turbulence. Such turbu-  
lence influences the effective heat transfer characteristics  
and gives false readings. Excess turbulence removes more  
heat from some surfaces and less heat from others, possibly  
causing uneven overheating.  
Ambient  
temperature  
sensor  
Airflow  
collimator  
Both sides of the UUT are studied since there are different  
thermal gradients on each side. The adjustable heating element  
and fan, built-in temperature gauges, and no-contact IR camera mean  
that power supplies are tested in real-world conditions.  
Figure 10. Vertical Wind Tunnel  
This product is subject to the following operating requirements  
and the Life and Safety Critical Application Sales Policy:  
Refer to: http://www.murata-ps.com/requirements/  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
ISO 9001 and 14001 REGISTERED  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
notice.  
© 2016 Murata Power Solutions, Inc.  
www.murata-ps.com/support  
MDC_OKL2-T20-W12.B02 Page 19 of 19  

相关型号:

OKL2-T/20-W12N2-C/S

DC-DC Regulated Power Supply Module, 1 Output, 110W, Hybrid, LGA-10
MURATA

OKL2-T/20-W12P2-C

DC-DC Regulated Power Supply Module
MURATA

OKL2-T/20-W12P2-C/S

DC-DC Regulated Power Supply Module, 1 Output, 110W, Hybrid, LGA-10
MURATA

OKL2-T/20-W5N-C

民用设备,工业设备
MURATA

OKL2-T/20-W5P-C

DC-DC Regulated Power Supply Module
MURATA

OKL2-T/3-W5N-C

Programmable Output 3-Amp iLGA SMT PoLs
MURATA

OKL2-T/3-W5P-C

Programmable Output 3-Amp iLGA SMT PoLs
MURATA

OKL2-T/6-W5N-C

Programmable Output 6-Amp iLGA SMT PoLs
MURATA

OKL2-T/6-W5P-C

Programmable Output 6-Amp iLGA SMT PoLs
MURATA

OKLP-X/35-W12-C

DC-DC Regulated Power Supply Module, 1 Output, 82.5W, Hybrid, PACKAGE-11
MURATA

OKLP-X/60-W12A-C

DC-DC Regulated Power Supply Module, 1 Output, 115.5W, Hybrid, PACKAGE-16
MURATA

OKPA170CA

STAND-OFF VOLTAGE-30 TO 288 Volts 30000 Watt Peak Pulse Power
NJSEMI