Adjustable Output 3 and 5-Amp DOSA-SMT PoLs; 可调输出3和5安培DOSA -SMT的POL型号: | OKY-T |
厂家: | muRata |
描述: | Adjustable Output 3 and 5-Amp DOSA-SMT PoLs |
文件: | 总4页 (文件大小:151K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
OKY T/3, T/5-W5 Series
s
Adjustable Output 3 and 5-Amp DOSA-SMT PoLs
PRODUCT OVERVIEW
The OKY-T/3 and -T/5 series are miniature non-
isolated Point-of-Load (POL) switch mode DC/DC
power converters for embedded applications. The
module is fully compatible with Distributed-power
Open Standards Alliance (DOSA) industry-standard
specifications (www.dosapower.com). Applications
frequency synchronous buck converter switching
topology, the high power conversion efficient Point
of Load (POL) module features programmable
output voltage and On/Off control. These converters
also include under voltage lock out (UVLO), output
short circuit protection, over-current and over
include powering CPU’s, datacom/telecom systems, temperature protections.
distributed bus architectures (DBA), programmable
logic and mixed voltage systems.
The wide input range is 2.4 to 5.5 Volts DC. Two
maximum output currents are offered, 3 Amps (T/3
models) or 5 Amps (T/5 models). Based on fixed-
These units are designed to meet all standard
UL/EN/IEC 60950-1 safety and FCC EMI/RFI
emissions certifications and RoHS-6 hazardous
substance compliance.
Typical unit
FEATURES
■ Non-isolated SMT POL DC/DC power module
■ 2.4-5.5Vdc input voltage range
■ Programmable output voltage from 0.75-3.63Vdc
■ 3 Amp (T/3) or 5 Amp (T/5) output current models
■ Drives 1000 μF capacitive loads
Contents of Full Data Sheet
Description, Connection Diagram, Photograph
Page
1
Ordering Guide, Model Numbering
Mechanical Specifications, Input/Output Pinout
Detailed Electrical Specifications
Output Voltage Adjustment, Soldering Guidelines
Application Notes
2
3
4
5
■ High power conversion efficiency 94% at 3.3 Vout
■ Outstanding thermal derating performance
■ Over temperature and over current protection
■ On/Off control
6
OKY-T/3-W5 Performance Data and Oscillograms
OKY-T/5-W5 Performance Data and Oscillograms
Tape and Reel Information
9
13
19
■ UL/EN/IEC 60950-1 safety
■ Industry-standard (DOSA) surface-mount package
■ RoHS 6 hazardous substance compliance
Connection Diagram
+Vin
+Vout
tꢀ4XJUDIJOH
tꢀ'JMUFST
F1
On/Off
Control
Controller
tꢀ$VSSFOUꢀ4FOTF
External
DC
Trim
Power
Source
Reference and
Error Amplifier
Open = On
Closed = Off
Common
Common
Figure 1. OKY-T/3, -T/5
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See specifications.
For full details go to
This datwawws.mhuraeta-eps.ctomc/roohsntains core information only. Please click here for the full data sheet.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_MDC_OKY-T/3,T/5-W5 Series.A01 D7Short Page 1 of 4
OKY T/3, T/5-W5 Series
Adjustable Output 3 and 5-Amp DOSA-SMT PoLs
Performance Specifications and Ordering Guide
ORDERING GUIDE
Output
R/N (mVp-p)➄ Regulation (Max.)➂
Input
Package
Efficiency
IOUT
IIN,
IIN,
VIN Nom. Range no load full load
(Volts) (Volts) ꢀ (mA) (Amps) Min.
VOUT
(Amps Power
max) (Watts)
Root Model ➁
(Volts)
Max.
Line
Load
Typ.
Case C72 ➀
Pinout
0.47 x 0.82 x 0.28
(11.9 x 20.8 x 7.0)
OKY-T/3-W5N-C 0.7525-3.63 ➅
OKY-T/3-W5P-C 0.7525-3.63 ➅
OKY-T/5-W5N-C 0.7525-3.63 ➅
OKY-T/5-W5P-C 0.7525-3.63 ➅
3
3
5
5
10.9
10.9
18
20
0.2%
1.5%
5
5
5
5
2.4-5.5
2.4-5.5
2.4-5.5
2.4-5.5
45
45
35
35
2.1
2.1
3.5
3.5
92% 94.4%
92% 94.4%
P78
0.47 x 0.82 x 0.28
(11.9 x 20.8 x 7.0)
20
20
20
0.2%
0.2%
0.2%
1.5%
1%
P78
P78
P78
0.47 x 0.82 x 0.28
(11.9 x 20.8 x 7.0)
92%
92%
96%
96%
0.47 x 0.82 x 0.28
(11.9 x 20.8 x 7.0)
18
1%
➀ Dimensions are in inches (mm).
ꢀꢁVin must be 0.5V or higher than Vout.
ꢂꢁRipple and Noise is shown at Vout=1V.
➅ꢁOutput range is shown at 50% load.
➁ These are partial model numbers. Please refer to the part number structure for complete ordering part numbers.
➂
All specifications are at nominal line voltage, Vout=nominal (3.3V) and full load, +25 ˚C. unless otherwise noted.
Output capacitors are 1 μF ceramic and 10 μF electrolytic in parallel. Input cap is 22 μF. See detailed specifica-
tions.
I/O caps are necessary for our test equipment and may not be needed for your application.
PART NUMBER STRUCTURE
O KY - T / 3 - W5 N - C
Output
Configuration:
Single Output,
Unipolar, Low Voltage
RoHS Hazardous
Substance Compliance
C = RoHS-6 (does not claim EU RoHS exemption
7b–lead in solder)
Non-Isolated Surface Mount
On/Off Polarity
P = Positive Polarity
N = Negative Polarity
Trimmable Output
Voltage Range
0.75-3.63V
Input Voltage Range
2.4-5.5V
Maximum Rated Output
Current in Amps
Note: Some model number combinations
may not be available. Contact Murata
Power Solutions for availability.
This data sheet contains core information only. Please click here for the full data sheet.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_MDC_OKY-T/3,T/5-W5 Series.A01 D7Short Page 2 of 4
OKY T/3, T/5-W5 Series
Adjustable Output 3 and 5-Amp DOSA-SMT PoLs
MECHANICAL SPECIFICATIONS
TOP VIEW
PIN #1 THIS
CORNER (FARSIDE)
11.9
0.47
ISOMETRIC
VIEW
PIN #1
10.67
0.420
REF
5.64
0.222
REF
NOZZLE
PICKUP
POINT
INPUT/OUTPUT CONNECTIONS
OKY-T/3, -T/5
20.8
0.82
Pin
1
2
Function
On/Off Control*
+VIN
SIDE VIEW
END VIEW
3
4
5
Ground (Common)
Trim
7.0
0.28
+VOUT
*The Remote On/Off can be provided with
either positive (P suffix) or negative (N
suffix) polarity
MTG PLANE
1.59
0.063
Dimensions are in inches (mm shown for ref. only).
Third Angle Projection
BOTTOM VIEW
1.5
0.06
2.29
0.090
TYP
Tolerances (unless otherwise specified):
.XX 0.02 (0.5)
.XXX 0.010 (0.25)
Angles 1˚
1.59
0.063
TYP
3
4
5
Components are shown for reference only.
8.63
0.340
1.8
0.07
[20.8] 0.82 REF
1
[2.41] 0.095 MIN
[2.79] 0.110 MAX
[3.05] 0.120 MIN
[3.43] 0.135 MAX
2
0.25
0.010
4.57
0.180
[11.9]
0.47
REF
8.63
0.340
[8.63] 0.340
12.69
0.500
[4.57]
0.180
[1.8]
0.070
REF
17.52
0.690
[8.63]
0.340
[1.52]
0.060
REF
[12.69]
0.500
MATERIAL:
SMT PINS: COPPER ALLOY
[17.52]
0.690
FINISH: (ALL PINS)
GOLD (5u"MIN) OVER NICKEL (50u" MIN)
RECOMMENDED PAD LAYOUT
Figure 2. OKY-T/3, -T/5 Mechanical Outline
This data sheet contains core information only. Please click here for the full data sheet.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_MDC_OKY-T/3,T/5-W5 Series.A01 D7Short Page 3 of 4
OKY T/3, T/5-W5 Series
Adjustable Output 3 and 5-Amp DOSA-SMT PoLs
This data sheet contains core information only. Please click here for the full data sheet.
USA:
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com
Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com
Canada:
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com
München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com
Murata Power Solutions, Inc.
France:
Germany:
Japan:
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 and 14001 REGISTERED
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com
04/13/09
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
China:
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
notice.
© 2009 Murata Power Solutions, Inc.
Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_MDC_OKY-T/3,T/5-W5 Series.A01 D7Short Page 4 of 4
相关型号:
©2020 ICPDF网 联系我们和版权申明