OKY2-T/60-W12NA-C [MURATA]

DC-DC Regulated Power Supply Module,;
OKY2-T/60-W12NA-C
型号: OKY2-T/60-W12NA-C
厂家: muRata    muRata
描述:

DC-DC Regulated Power Supply Module,

文件: 总15页 (文件大小:687K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
PRODUCT OVERVIEW  
switching topology, this high power  
The OKY2-T/60-W12 series are  
miniature non-isolated Point-of-Load (PoL)  
DC-DC power converters for embedded  
applications. The tiny form factor measures  
only 1.3 x 0.9 x 0.38 inches (33.0 x 22.9 x  
9.6 mm). Applications include powering  
CPU’s, datacom/telecom systems,  
Distributed Bus Architectures (DBA),  
programmable logic and mixed voltage  
systems.  
conversion efficient PoL module features  
programmable output voltage, On/Off control,  
Power Good signal, sequence/tracking,  
parallel operation and optional SYNC/CLKOUT  
function.  
These converters also include under  
voltage lock out (UVLO), output short circuit  
protection, over-current, over-temperature,  
over-voltage and under-voltage protection.  
These units are designed to meet all  
standard UL/EN/IEC 60950-1 safety and FCC  
EMI/RFI emissions certifications and RoHS-6  
hazardous substance compliance.  
Typical unit  
FEATURES  
4.5-14Vdc input voltage range  
Programmable output voltage from0.7-2.0Vdc  
Up to 60 Amps of output current  
The converters have a wide input voltage  
range of 4.5 to 14Vdc and a maximum  
output current of 60 Amps. Based on a fixed  
frequency synchronous buck converter  
Drives 20,000μF tantalum capacitive loads  
Industry Standard surface mount package  
1.3 x 0.9 x 0.38 inches (33.0 x 22.9 x 9.6 mm)  
High efficiency of87.5%, (typical)  
Outstanding thermal deratingperformance  
Over temperature and over currentprotection  
Over voltage and under voltageprotection  
On/Off control (Positive or Negative logic)  
Power Good signal  
Sequence/Tracking function  
Parallel operation up to 3 modules  
Optional SYNC/CLKOUT function  
RoHS-6 hazardous substance compliance  
+Vin  
+Vout  
• Switching  
• Filters  
F1  
On/Off  
Control  
+Sense  
-Sense  
Controller  
• Current Sense  
External  
Open=On  
DC  
-Trim  
Closed=Off  
Power  
Source  
(Positive  
Reference and  
Error Amplifier  
On/Off)  
+Trim  
Common  
CLKOUT  
SYNC  
Sequence/ Tracking  
Power Good  
Figure 1. Connection Diagram  
Typical topology is shown. Murata Power Solutions recommends an external fuse.  
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 1 of 15  
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE  
 
Output  
Input  
Package  
Efficiency On/Off  
Regulation (max.)  
Line (%) Load (%)  
Model Number  
SYNC  
Vout  
Iout  
Power R/N (mVp-p)  
(Amps,max) (Watts)  
Vin nom  
(Vdc)  
Range Iin, no load  
(Vdc)  
Iin, full load  
(Amps)  
(%)  
87.5  
87.5  
87.5  
87.5  
Logic  
(Vdc)  
Max.  
(mA)  
inches (mm)  
1.30x0.9x0.38  
(33.0x22.9x9.6)  
OKY2-T/60-W12PA-C  
OKY2-T/60-W12P-C  
OKY2-T/60-W12NA-C  
OKY2-T/60-W12N-C  
0.7-2.0  
0.7-2.0  
0.7-2.0  
0.7-2.0  
60  
60  
60  
60  
120  
120  
120  
120  
50  
±0.25 ±0.25  
±0.25 ±0.25  
±0.25 ±0.25  
±0.25 ±0.25  
12  
12  
12  
12  
4.5-14  
160  
11.6  
11.6  
11.6  
11.6  
Pos.  
Pos.  
Neg.  
Neg.  
Yes  
No  
1.30x0.9x0.38  
(33.0x22.9x9.6)  
50  
50  
50  
4.5-14  
4.5-14  
4.5-14  
160  
160  
160  
1.30x0.9x0.38  
(33.0x22.9x9.6)  
Yes  
No  
1.30x0.9x0.38  
(33.0x22.9x9.6)  
1. Please refer to the Part Number Structure for additional ordering information and options.  
2. All specifications are at nominal line voltage, Vout=nominal (2.0V) and full load, +25°C unless  
otherwise noted. Output capacitors are 100 uF*1 ceramic and 470uF*10 tantalum (Panasonic  
POSCAP). Input cap is 22 uF*3 ceramic and 560uF*1 electrolytic (Panasonic OS- CON). See  
detailed specifications. I/O caps are necessary for our test equipment.  
3. Use adequate ground plane and copper thickness adjacent to the converter.  
PART NUMBER STRUCTURE  
OKY2 - T / 60 - W12 N A - C  
RoHS Hazardous Materialscompliance  
C = RoHS-6 (does not claim EU RoHS exemption 7b–lead in solder)  
Okami Series  
Non-isolated PoL  
Y = Surface mount package  
2 = Sequence/Tracking  
A = SYNC/CLKOUT(optional)  
T = Trimmable Output  
Voltage Range: (0.7-2.0Vdc)  
On/Off Control Logic  
N = Negative  
P = Positive  
Maximum RatedOutput  
Current inAmps  
Input VoltageRange:  
W12 = 4.5-14Vdc (12Vdcnominal)  
Product Marking  
Model Number  
OKY2-T/60-W12PA-C  
OKY2-T/60-W12P-C  
OKY2-T/60-W12NA-C  
OKY2-T/60-W12N-C  
Product Code  
Y21160  
Rev Code  
2
1
2
1
Because of the small size of these products, the product marking  
contains a character-reduced code to indicate the model number and  
manufacturing date code. Not all items on the marking are always  
used. Please note that the marking differs from the product  
photograph. Here is the layout of the Marking.  
Y21160  
Y20160  
Y20160  
Codes  
Layout  
The manufacturing date code is four characters:  
First character - Manufacturing information  
Second character - Last digit of manufacturing year, example 2011  
Third character - Month code (1 through 9 and O through D)  
Fourth character - Day code (1 through 9 = 1 to 9, 10=O and  
11 through 31 = A through Z)  
Rev code  
②③  
②③④⑤⑥⑦ Product code  
⑧⑨⑩⑪ Manufacturing date code  
④⑤⑥⑦  
⑧⑨⑩⑪  
The marking contains three rows of information:  
First and second row – Rev code and product code  
Third row - Manufacturing date code  
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 2 of 15  
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
FUNCTIONAL SPECIFICATIONS  
ABSOLUTEMAXIMUMRATINGS  
Input Voltage, Continuous  
ON/OFF Pin  
SEQ Pin  
SYNC Pin  
Minimum  
-0.3  
-0.3  
-0.3  
-0.3  
Typical/Nominal  
Maximum  
Units  
Vdc  
Vdc  
V
Conditions  
14  
14  
3
Power on, referred to-Vin  
Power on, referred to-Vin  
Power on, referred to-Vin  
Power on, referred to-Vin  
Current-limited, no damage,short-circuit  
protected  
6
V
Source ONLY  
SHARE/PGOOD/CLKOUT/  
±Trim Pins  
Output Current  
0
60  
A
StorageTemperatureRange  
Vin = Zero (no power)  
-55  
125  
°C  
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other thanthose  
listed in the Performance/Functional Specifications Table is not implied or recommended.  
Conditions  
INPUT  
OperatingVoltageRange  
Start-up threshold  
Undervoltage shutdown  
Overvoltage shutdown  
Internal Filter Type  
4.5  
12  
4.3  
4.0  
Vo*120%  
Capacitive  
14  
Vdc  
Vdc  
Vdc  
Vdc  
Rising input voltage  
Note 15  
Inputcurrent  
Full Load Conditions  
Low Line  
Vin = nominal  
Vin = minimum  
11.6  
30  
A
A
NoLoadCurrent  
Iout = minimum, unit = ON  
160  
1
mA  
mA  
Shut-Down Mode InputCurrent  
Tracking/Sequencing  
Operating Voltage Range  
SlewRate(Power-Up)  
SlewRate(Power-Down)  
Trackingaccuracy,risinginput  
Trackingaccuracy,fallinginput  
3
2
1
V
V/ms  
V/ms  
Vout = 100mV of Sequence In (TYP)  
Vout = 200mV of Sequence In (TYP)  
GENERAL and SAFETY  
Efficiency  
Vin =5V, Vout= 2V, full load  
Vin=5V,Vout=2V,Io=50A  
87.5  
90  
%
Certified to UL-60950-1, CSA-C22.2 No. 60950-1,  
IEC/EN60950-1, 2nd edition(pending)  
Safety  
Per Telcordia SR-332 Issue 2, Method 1, Class 3,  
Ground Benign, Tambient =+25°C  
Per Telcordia SR-332 Issue 3, Method 1, Class 3,  
Ground Benign, Tambient =+25°C  
Calculated MTBF (Note 4a)  
Calculated MTBF (Note 4b)  
322,334  
Hours  
Hours  
1,643,147  
DYNAMIC CHARACTERISTICS  
Fixed Switching Frequency  
Startup Time  
310  
4.5  
4.5  
kHz  
mS  
mS  
Vout=nominal (Vin On to 90% of Vo)  
Vout=nominal (Remote On to 90% of Vo)  
Startup Time  
2.5  
Dynamic Load
 
Response  
DynamicLoadPeakDeviation  
(25-75% load step, di/dt)  
same as above  
A/μSec  
Voset  
3.0%  
FEATURES  
RemoteOn/Off Control (Note 5)  
“N” suffix:  
NegativeLogic,ONstate  
NegativeLogic,OFFstate  
Control Current  
ON = Open pin or -0.3V to +0.6V. max.  
OFF = +3.0Vmin. to +Vin max.  
Open collector/drain  
-0.3  
3.0  
0.6  
Vin max  
3.3  
Vdc  
Vdc  
mA  
“P” suffix:  
PositiveLogic,ONstate  
PositiveLogic,OFFstate  
Control Current  
ON = +3.0Vmin. to +Vin max.  
OFF =Open or -0.3V to +0.6V.max.  
Open collector/drain  
3.0  
-0.3  
Vin max  
0.6  
3.3  
V
V
mA  
Power-Good Output (Pulled up to 5.4Vreg(TYP) internally)  
PGood TRUE (HI)  
PGood FALSE (LO)  
(Vset –13%) < Vout < (Vset +13%)  
Out of above range  
OPTIONS (OKY2-T/60-W12NA-C & OKY2-T/60-W12PA-C only)  
SYNC  
InputVoltageRange  
Signal Low  
Signal High  
V
V
-0.3  
3.0  
1.0  
Vin max or to 5.8  
InputFrequencyRange  
InputWaveForm(Note18)  
CLKOUT  
280 to 340  
Square Plus Waveform (Duty cycle 20-80%)  
kHz  
Output voltagerange  
Waveform  
Duty cycle  
-0.3  
Vin max or to 5.8  
V
Square Plus Waveform  
50  
%
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 3 of 15  
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
FUNCTIONAL SPECIFICATIONS (CONT.)  
OUTPUT  
Total Output Power  
Voltage  
OutputVoltageRange  
Minimum Loading  
See Derating  
Note 13  
0
120  
2
W
0.7  
Vdc  
None  
Accuracy (50% load, untrimmed)  
Overvoltage Protection  
Undervoltage Protection  
Current  
2.0% of Vnominal  
>113%Vset(Hiccup),>120%Vset(Latch)  
<87%Vset(Hiccup)  
Vdc  
Vdc  
Vdc  
Note 16  
OutputCurrentRange  
CurrentLimitInception  
Short Circuit  
0
60  
A
A
98% of Vnom., afterwarmup  
100  
Short Circuit Duration  
(remove short for recovery)  
Shortcircuitprotectionmethod  
Output shorted to ground, nodamage  
Continuous  
Current limiting  
Prebias Start-up  
Converter will start up if the external output voltage is less than Vnominal.  
Regulation  
Line Regulation  
Vin = min. to max.,Vout = nom., Iout = nom.  
Note 8  
0.25  
50  
% of Vout  
mV pk-pk  
μF  
Ripple and Noise (20MHz bandwidth)  
4800  
280  
20000  
90  
Maximum Capacitive Loading (Note 14)  
ParallelandSYNCoperation  
Maximum parallel units (withSYNC)  
Maximum parallel units (w/o SYNC)  
LoadShareAccuracy  
External input frequency range (Note 18)  
MECHANICAL  
Outline Dimensions  
(Please refer to outline drawing)  
Weight  
Cap-ESR>0.01 Ohms  
3
2
Units  
Units  
%
Io=Iomax  
LxWxH  
340  
kHz  
1.30x0.9x0.38  
33.0x22.9x9.6  
0.39  
Inches  
mm  
Ounces  
Grams  
11.5  
ENVIRONMENTAL  
Operating Ambient TemperatureRange  
StorageTemperature  
Thermal Protection/Shutdown  
Relative Humidity  
With Derating (Note 9)  
Vin = Zero (no power)  
Measured in center  
-40  
-55  
85  
125  
°C  
°C  
°C  
135  
To 85%/+85°C, non-condensing  
RoHS-6  
RoHS rating  
Specification Notes  
(1) Specifications are typical at +25°C, Vin=nominal (+12V.), Vout=nominal (+2V), full load,  
external caps and natural convection unless otherwise indicated. Extended tests at full power  
must supply substantial forced airflow. All models are tested and specified with external 100  
uF*1 ceramic and 470uF*10 tantalum output capacitors and a 22 uF*3 ceramic and 560uF*1  
electrolytic external input capacitor. All capacitors are low ESR types. These capacitors are  
necessary to accommodate our test equipment and may not be required to achieve specified  
performance in your applications. However, Murata recommends installation of these  
capacitors. All models are stable and regulate within spec under no-load conditions.  
(2) Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input  
filtering is Cin=2 x 100 uF ceramic, Cbus=1000 uF electrolytic, Lbus=1 uH.  
(3) Note that Maximum Power Derating curves indicate an average current at nominal input  
voltage. At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief  
full current outputs if the total RMS current over time does not exceed the Derating curve.  
(4a) Mean Time Before Failure is calculated using the Telcordia (Belcore) Issue 2, Method 1, Case  
3, Ground Benign conditions, Tpcboard = +25°C, full output load, natural air convection.  
(4b) Mean Time Before Failure is calculated using the Telcordia (Belcore) Issue 3, Method 1, Case  
3, Ground Benign conditions, Tpcboard = +25°C, full output load, natural air convection.  
(5) The On/Off Control Input should use either a switch or an open collector/open drain transistor  
referenced to Input Common. A logic gate may also be used by applying appropriate external  
voltages which do not exceed +Vin  
(8) Output noise may be further reduced by adding an external filter. At zero output current, the  
output may contain low frequency components which exceed the ripple specification. The output  
may be operated indefinitely with no load.  
(9) All models are fully operational and meet published specifications, including “cold start” at -  
40°C.  
(10) Regulation specifications describe the deviation as the line input voltage or output load current is  
varied from a nominal midpoint value to either extreme.  
(11) Other input or output voltage ranges will be reviewed under scheduled quantity special order.  
(12) Maximum PC board temperature is measured with the sensor in the center of the converter.  
(13) Do not exceed maximum power specifications when adjusting the output trim.  
(14) The maximum output capacitive loads depend on the Equivalent Series Resistance (ESR) of the  
external output capacitor and, to a lesser extent, the distance and series impedance to the load.  
Larger caps will reduce output noise but may change the transient response. Newer ceramic  
caps with very low ESR may require lower capacitor values to avoid instability. Thoroughly test  
your capacitors in the application. Please refer to the Output Capacitive Load Application Note.  
(15) Do not allow the input voltage to degrade lower than the input under voltage shutdown voltage at  
all times. Otherwise, you risk having the converter turn off. The under voltage shutdown is not  
latching and will attempt to recover when the input is brought back into normal operating range.  
(16) The outputs are not intended to sink appreciable reverse current.  
(17) “Hiccup” over current operation repeatedly attempts to restart the converter with a brief, full-  
current output If the over current condition still exists the restart current will be removed and  
then try again. This short current pulse prevents overheating and damaging the converter. Once  
the fault is removed, the converter immediately recovers normal operation.  
(18) The switching frequency will lock to an external frequency (square pulse waveform), typically the  
CLKOUT signal from another converter or external clock. The internal oscillator synchronizes  
with the leading edge of the input signal.  
(6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the  
selected setting.  
(7) “Hiccup” overcurrent operation repeatedly attempts to restart the converter with a brief, full-  
current output. If the overcurrent condition still exists, the restart current will be removed and  
then tried again. This short current pulse prevents overheating and damaging the converter.  
Once the fault is removed, the converter immediately recovers normal operation.  
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 4 of 15  
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
PERFORMANCE DATA AND OSCILLOGRAMS  
Efficiency vs. Line Voltage and Load Current @ +25°C. (Vout = 0.7V)  
Maximum Current Temperature Derating at Sea Level (Vin=12V, Vout=0.7V)  
70  
100  
95  
60  
50  
40  
30  
20  
10  
0
90  
0.2m/s(40LFM)  
0.5m/s(100LFM)  
1m/s(200LFM)  
1.5m/s(300LFM)  
2m/s(400LFM)  
85  
80  
Vin=4.5V  
Vin=12V  
Vin=14V  
75  
70  
65  
0
10  
20  
30  
40  
50  
60  
Load Current [Amps]  
25  
35  
45  
55  
65  
75  
85  
95  
Ta [degC]  
On/Off Enable Delay (Vin=12V, Vout=0.7V, Iout=60A, Cload=4800uF)  
Trace1=Enable, Trace2=Vout  
Output Ripple and Noise  
(Vin=12V, Vout=0.7V, Iout=60A, Cload=4800uF, ScopeBW=20MHz)  
Step Load Transient Response (Vin=12V, Vout=0.7V, Cload=4800uF,  
Iout=15A to 45A) Trace 2=Vout, 50 mV/div, Trace 4=Iout, 20A/div.  
Step Load Transient Response (Vin=12V, Vout=0.7V, Cload=4800uF,  
Iout=45A to 15A) Trace 2=Vout, 50 mV/div, Trace 4=Iout, 20A/div.  
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 5 of 15  
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
PERFORMANCE DATA AND OSCILLOGRAMS  
Efficiency vs. Line Voltage and Load Current @ +25°C. (Vout = 1.2V)  
Maximum Current Temperature Derating at Sea Level (Vin=12V, Vout=1.2V)  
70  
100  
95  
60  
50  
40  
30  
20  
10  
0
90  
0.2m/s(40LFM)  
0.5m/s(100LFM)  
1m/s(200LFM)  
1.5m/s(300LFM)  
2m/s(400LFM)  
85  
80  
Vin=4.5V  
Vin=12V  
Vin=14V  
75  
70  
65  
0
10  
20  
30  
40  
50  
60  
Load Current [Amps]  
25  
35  
45  
55  
65  
75  
85  
95  
Ta [degC]  
On/Off Enable Delay (Vin=12V, Vout=1.2V, Iout=60A, Cload=4800uF)  
Trace1=Enable, Trace2=Vout  
Output Ripple and Noise  
(Vin=12V, Vout=1.2V, Iout=60A, Cload=4800uF, ScopeBW=20MHz)  
Step Load Transient Response (Vin=12V, Vout=1.2V, Cload=4800uF,  
Iout=15A to 45A) Trace 2=Vout, 50 mV/div, Trace 4=Iout, 20A/div.  
Step Load Transient Response (Vin=12V, Vout=1.2V, Cload=4800uF,  
Iout=45A to 15A) Trace 2=Vout, 50 mV/div, Trace 4=Iout, 20A/div.  
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 6 of 15  
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
PERFORMANCE DATA AND OSCILLOGRAMS  
Efficiency vs. Line Voltage and Load Current @ +25°C. (Vout = 2.0V)  
Maximum Current Temperature Derating at Sea Level (Vin=12V, Vout=2.0V)  
70  
100  
95  
60  
50  
40  
30  
20  
10  
0
90  
0.2m/s(40LFM)  
0.5m/s(100LFM)  
1m/s(200LFM)  
1.5m/s(300LFM)  
2m/s(400LFM)  
85  
Vin=4.5V  
Vin=12V  
Vin=14V  
80  
75  
70  
65  
0
10  
20  
30  
40  
50  
60  
25  
35  
45  
55  
65  
75  
85  
95  
Load Current [Amps]  
Ta [degC]  
On/Off Enable Delay (Vin=12V, Vout=2.0V, Iout=60A, Cload=4800uF)  
Trace1=Enable, Trace2=Vout  
Output Ripple and Noise  
(Vin=12V, Vout=2.0V, Iout=60A, Cload=4800uF, ScopeBW=20MHz)  
Step Load Transient Response (Vin=12V, Vout=2.0V, Cload=4800uF,  
Iout=15A to 45A) Trace 2=Vout, 50 mV/div, Trace 4=Iout, 20A/div.  
Step Load Transient Response (Vin=12V, Vout=2.0V, Cload=4800uF,  
Iout=45A to 15A) Trace 2=Vout, 50 mV/div, Trace 4=Iout, 20A/div.  
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 7 of 15  
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
MECHANICAL SPECIFICATIONS  
INPUT/OUTPUT CONNECTIONS  
Function  
Vin  
Pin  
1
GND  
Vout  
2
3
Vout  
4
GND  
Vin  
5
6
SEQ  
7
PGOOD  
ON/OFF  
VS-  
8
9
10  
11  
12  
13  
14  
15  
16  
VS+  
+Trim  
-Trim  
SHARE  
CLKOUT*  
SYNC*  
* CLKOUT and SYNC pins are optional  
(include A suffix). Please see the Part  
Number Structure on Page 2.  
Dimensions are in mm (inches) shown for ref. only.  
Tolerances (unless otherwise specified):  
.XX 0.02 (0.5)  
.XXX 0.010 (0.25)  
Angles 2˚  
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 8 of 15  
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
TAPE AND REEL INFORMATION  
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 9 of 15  
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
TAPE SPECIFICATIONS  
Dimensions are in mm (inches) shown for ref. only.  
Tolerances (unless otherwise specified):  
.XX 0.02 (0.5)  
.XXX 0.010 (0.25)  
Angles 2˚  
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 10 of 15  
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
TECHNICAL NOTES  
Input Fusing  
Recommended Output Filtering  
Certain applications and/or safety agencies may require fuses at the inputs  
of power conversion components. Fuses should also be used when there is  
the possibility of sustained input voltage reversal which is not current  
limited. For greatest safety, we recommend a fast blow fuse installed in  
the ungrounded input supply line.  
The installer must observe all relevant safety standards and regulations.  
For safety agency approvals, install the converter in compliance with the  
end-user safety standard.  
The converter will achieve its rated output ripple and noise with additional  
external capacitor. The user may install more external output capacitance  
to reduce the ripple even further or for improved dynamic response. Again,  
use low-ESR ceramic (Murata GRM32 series) and tantalum capacitors  
such as Panasonic POSCAP. Initial values of 100 uF*1 ceramic type and  
470uF*10 tantalum type may be tried, either single or multiple capacitors  
in parallel. Mount these close to the converter. Measure the output ripple  
under your load conditions.  
Use only as much capacitance as required to achieve your ripple and noise  
objectives. Excessive capacitance can make step load recovery sluggish or  
possibly introduce instability. Do not exceed the maximum rated output  
capacitance listed in the specifications.  
Input Under-Voltage Shutdown and Start-Up Threshold  
Under normal start-up conditions, converters will not begin to regulate  
properly until the ramping-up input voltage exceeds and remains at the  
Start-Up Threshold Voltage (see Specifications). Once operating,  
converters will not turn off until the input voltage drops below the Under-  
Voltage Shutdown Limit. Subsequent restart will not occur until the input  
voltage rises again above the Start-Up Threshold. This built-in hysteresis  
prevents any unstable on/off operation at a single input voltage.  
Users should be aware however of input sources near the Under-Voltage  
Shutdown whose voltage decays as input current is consumed (such as  
capacitor inputs), the converter shuts off and then restarts as the external  
capacitor recharges. Such situations could oscillate. To prevent this, make  
sure the operating input voltage is well above the UV Shutdown voltage AT  
ALL TIMES.  
Input Ripple Current and Output Noise  
All models in this converter series are tested and specified for input  
reflected ripple current and output noise using designated external  
input/output components, circuits and layout as shown in the figures  
below.  
In the figure below, the two copper strips simulate real-world printed  
circuit impedances between the power supply and its load. In order to  
minimize circuit errors and standardize tests between units, scope  
measurements should be made using BNC connectors or the probe ground  
should not exceed one half inch and soldered directly to the test circuit.  
Start-Up Time  
Assuming that the output current is set at the rated maximum, the Vin to  
Vout Start-Up Time (see Specifications) is the time interval between the  
point when the ramping input voltage crosses the Start-Up Threshold and  
the fully loaded regulated output voltage enters and remains within its  
specified accuracy band. Actual measured times will vary with input  
source impedance, external input capacitance, input voltage slew rate and  
final value of the input voltage as it appears at the converter.  
These converters include a soft start circuit to moderate the duty cycle of  
its PWM controller at power up, thereby limiting the input inrush current.  
The On/Off Remote Control interval from On command to Vout regulated  
assumes that the converter already has its input voltage stabilized above  
the Start-Up Threshold before the On command. The interval is measured  
from the On command until the output enters and remains within its  
specified accuracy band. The specification assumes that the output is fully  
loaded at maximum rated current. Similar conditions apply to the On to  
Vout regulated specification such as external load capacitance and soft  
start circuitry.  
Measuring Output Ripple and Noise (PARD)  
Minimum Output Loading Requirements  
Recommended Input Filtering  
All models regulate within specification and are stable under no load to full  
load conditions. Operation under no load might however slightly increase  
output ripple and noise.  
The user must assure that the input source has low AC impedance to  
provide dynamic stability and that the input supply has little or no inductive  
content, including long distributed wiring to a remote power supply. The  
converter will operate with no additional external capacitance if these  
conditions are met.  
For best performance, we recommend installing a low-ESR capacitor  
immediately adjacent to the converter’s input terminals. The capacitor  
should be a ceramic type such as the Murata GRM32 series and a  
electrolytic type such as Panasonic OS-CON series. Initial suggested  
capacitor values are 22 uF*3 ceramic type and 560uF*1 electrolytic type,  
rated at twice the expected maximum input voltage. Make sure that the  
input terminals do not go below the under voltage shutdown voltage at all  
times. More input bulk capacitance may be added in parallel (either  
electrolytic or tantalum) if needed.  
Thermal Shutdown  
To prevent many over temperature problems and damage, these  
converters include thermal shutdown circuitry. If environmental conditions  
cause the temperature of the DC/DC’s to rise above the Operating  
Temperature Range  
up to the shutdown temperature, an on-board electronic temperature  
sensor will power down the unit. When the temperature decreases below  
the turn-on threshold, the converter will automatically restart.  
CAUTION: If you operate too close to the thermal limits, the converter may  
shut down suddenly without warning. Be sure to thoroughly you’re your  
application to avoid unplanned thermal shutdown.  
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 11 of 15  
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
Temperature Derating Curves  
converter could operate sink mode in a very short time of switching cycles,  
to avoid high negative voltage ringing until the UV condition removed.)  
The graphs in this data sheet illustrate typical operation under a variety of  
conditions. The derating curves show the maximum continuous ambient  
air temperature and decreasing maximum output current which is  
acceptable under increasing forced airflow measured in Linear Feet per  
Minute (“LFM”). Note that these are AVERAGE measurements. The  
converter will accept brief increases in current or reduced airflow as long  
as the average is not exceeded.  
Note that the temperatures are of the ambient airflow, not the converter  
itself which is obviously running at higher temperature than the outside air.  
Also note that very low flow rates (below about 25 LFM) are similar to  
“natural convection,” that is, not using fan-forced airflow. Murata makes  
Characterization measurements in a closed cycle wind tunnel with  
calibrated airflow. We use both thermocouples and an infrared camera  
system to observe thermal performance.  
Output Voltage Sequencing  
The OKY2 modules include a sequencing feature that enables users to  
implement various types of output voltage sequencing in their applications.  
This is accomplished via an additional sequencing pin. When not using the  
sequencing feature, either tie the sequence pin to Vin or leave it  
unconnected. When an analog voltage is applied to the sequence pin, the  
output voltage tracks this voltage until the output reaches the set-point  
voltage. The final value of the sequence voltage must be set higher than  
the setpoint voltage of the module. The output voltage follows the voltage  
on the sequence pin on a one-to-one volt basis. By connecting multiple  
modules together, multiple modules can track their output voltages to the  
voltage applied on the sequence pin. For proper voltage sequencing, fi rst,  
input voltage is applied to the module. The On/Off pin of the module is left  
unconnected (or tied to GND for negative logic modules or tied to Vin for  
positive logic modules) so that the module is ON by default. After applying  
input voltage to the module, a minimum 10msec delay is required before  
applying voltage on the sequence pin. During this time, a voltage of 100mV  
CAUTION: These graphs are all collected at slightly above Sea Level  
altitude. Be sure to reduce the derating for higher density altitude.  
Output Current Limiting  
Current limiting inception is defined as the point at which full power falls  
below the rated tolerance. See the Performance/Functional Specifications.  
Note particularly that the output current may briefly rise above its rated  
value in normal operation as long as the average output power is not  
exceeded. This enhances reliability and continued operation of your  
application. If the output current is too high, the converter will enter the  
short circuit condition.  
(
20 mV) is maintained on the sequence pin. This delay gives the module  
enough time to complete its internal power-up soft-start cycle. During the  
delay time, the sequence pin should be held close to ground (nominally  
100mV 20 mV). This is required to keep the internal op-amp out of  
saturation thus preventing output overshoot during the start of the  
sequencing ramp.  
Remote On/Off Control  
Output Short Circuit Condition  
The remote On/Off Control can be ordered with either polarity. Please refer  
to the Connection Diagram on page 1 for On/Off connections.  
Positive logic models are enabled when the On/Off pin is left open or is  
pulled high to +Vin with respect to -Vin. An internal bias current causes  
the open pin to rise to +Vin. Positive-polarity devices are disabled when  
the On/Off is grounded or brought to within a low voltage (see  
Specifications) with respect to -Vin.  
Negative logic devices are on (enabled) when the On/Off is open or brought  
to within a low voltage (see Specifications) with respect to -Vin. The device  
is off (disabled) when the On/Off is pulled high with respect to -Vin (see  
specifications).  
When a converter is in current-limit mode, the output voltage will drop as  
the output current demand increases. If the output voltage drops too low  
(approximately 98% of nominal output voltage for most models), the  
magnetically coupled voltage used to develop primary side voltages will  
also drop, thereby shutting down the PWM controller. Following a time-out  
period, the PWM will restart, causing the output voltage to begin ramping  
up to its appropriate value. If the short-circuit condition persists, another  
shutdown cycle will initiate. This rapid on/off cycling is called “hiccup  
mode”. The hiccup cycling reduces the average output current, thereby  
preventing excessive internal temperatures and/or component damage. A  
short circuit can be tolerated indefinitely.  
Dynamic control of the On/Off function should be able to sink appropriate  
signal current when brought low and withstand appropriate voltage when  
brought high. Be aware too that there is a finite time in milliseconds (see  
Specifications) between the time of On/Off Control activation and stable,  
regulated output. This time will vary slightly with output load type and  
current and input conditions.  
The “hiccup” system differs from older latching short circuit systems  
because you do not have to power down the converter to make it restart.  
The system will automatically restore operation as soon as the short circuit  
condition is removed.  
Output Over Voltage Protection  
OV protection is active upon converter (ON).An OV condition  
(>120%*Voset) would latch off permanently. The ON/OFF pin and PGOOD  
pin are also latched low at this OV event. The latch condition can be reset  
only by recycling Vin.  
There is another non-latch OV protection (>113%*Voset). At the condition  
the output over 113% OV, the converter will operate “sink” mode only until  
the output drops below 87%*Voset. After the output drops below 87%, the  
converter will operate “sink-source” mode (normal operation) again.  
Output Capacitive Load  
These converters do not require external capacitance added to achieve  
rated specifications. Users should only consider adding capacitance to  
reduce switching noise and/or to handle spike current load steps. Install  
only enough capacitance to achieve noise objectives. Excess external  
capacitance may cause regulation problems, degraded transient response  
and possible oscillation or instability.  
Synchronization (OKY2-T/60-W12NA-C & OKY2-T/60-W12PA-C only)  
These converters can be synchronized using an external signal. Details of  
the SYNC signal are provided in the Performance and Functional Specifi  
cations table. If the synchronization function is not being used, leave the  
SYNC pin floating. When synchronization function is used, output ripple  
may increase on some operating conditions. Please check the proper  
operation of this device with the peripheral circuits on your system.  
Output Under Voltage Protection  
The under voltage protection is NOT enabled until the end of soft-start  
condition. In a UV event, if the output drops below 87%*Voset due to some  
reason for example OV, OC, OT and dynamic load response, the converter  
will operate almost “source” mode only until UV condition is removed. (The  
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 12 of 15  
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
Output Voltage Adjustment  
CLKOUT (OKY2-T/60-W12NA-C & OKY2-T/60-W12PA-C only)  
Square wave with switching frequency is appeared CLKOUT pin. It is  
possible to synchronize other converters by connecting CLKOUT pin to  
SYNC pin of other converter. Details of the CLKOUT signal are provided in  
the Performance and Functional Specifications table. If the CLKOUT  
function is not being used, leave the CLKOUT pin floating.  
The output voltage may be adjusted over a limited range by connecting an  
external trim resistor (Rtrim) between the +Trim pin and –Trim pin. The  
Rtrim resistor must be a 1/10 Watt precision metal film type, 0.5%  
accuracy or better with low temperature coefficient, 100 ppm/°C. or  
better. Mount the resistor close to the converter with very short leads or  
use a surface mount trim resistor.  
In the table below, the calculated resistance is given. Do not exceed the  
specified limits of the output voltage or the converter’s maximum power  
rating when applying these resistors. Also, avoid high noise at the -Trim  
input. However, to prevent instability, you should never connect any  
capacitors to –Trim pin.  
Soldering Guidelines  
Murata recommends the specifications below when installing these  
converters. These specifications vary depending on the solder type.  
Exceeding these specifications may cause damage to the product. Your  
production environment may differ therefore please thoroughly review  
these guidelines with your process engineers.  
Output Voltage  
Calculated Rtrim (kΩ)  
Reflow Solder Operations for surface-mount products (SMT)  
For Sn/Ag/Cu based solders:  
2.0 V.  
1.8 V.  
1.5 V.  
1.2 V.  
1.0 V.  
0.70 V.  
10.80  
12.70  
17.50  
28.00  
46.60  
(open)  
Preheat Temperature  
Time over Liquidus  
Less than 1°C per second  
45 to 75 seconds  
Maximum Peak Temperature 260°C  
Cooling Rate  
Less than 3°C per second  
For Sn/Pb basedsolders:  
Preheat Temperature  
Time over Liquidus  
Less than 1°C per second  
60 to 75 seconds  
Maximum Peak Temperature 235°C  
Resistor Trim Equation, OKY2-T/60-W12 models  
Cooling Rate  
Less than 3°C per second  
(kꢀ) =  
Vout  
0.7  
Recommended Lead-free Solder Reflow Profile  
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 13 of 15  
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
PARALLEL OPERATION  
NOTES:  
.
The OKY2-T/60-W12N-C and OKY2-T/60-W12P-C can operate in parallel (up to 2 converters) without the SYNC function, by connecting each  
ISHARE, SEQ and ON/OFF terminals.  
.
The OKY2-T/60-W12NA-C and OKY2-T/60-W12PA-C can operate in parallel (up to 3 converters) with the SYNC function, by connecting each  
ISHARE, SEQ, ON/OFF, SYNC and CLKOUT terminals.  
(1) When using parallel operation, the temperature of some parts may increase in one of the products because there are some differences in the  
operating conditions between the first and second module. For this reason, please check the temperature of the products in your application.  
(2) When using parallel operation, please set no more than 80% of the sum of individual products because the current of each product may not be equal.  
(3) It is necessary to install Cin and Cout for each module.  
(4) To avoid OC, OV and UV protection malfunction, please set same values of Vout of each module and place each modules isometric alignment  
for Vin and Load. And it is recommended that the load may be started after PGOOD signal “High” because of same reason.  
(5) Parallel operation can be available among same parts N.O. only.  
(6) There is no redundancy function.  
Below is the recommended schematic diagram for parallel operation without the SYNC function:  
(OKY2-T/60-W12N-C and OKY2-T/60-W12P-C only)  
NOTE: Please shield well from any noise, especially SHARE, SEQ, VS+, VS- and ON/OFF lines to avoid any unexpected interference during operation.  
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 14 of 15  
OKY2-T/60-W12 Series  
Programmable Output 60-Amp SMT PoL  
Below is the recommended schematic diagram for parallel operation with the SYNC function:  
(OKY2-T/60-W12NA-C and OKY2-T/60-W12PA-C only)  
(1) Please shield well from any noise, especially SHARE, SEQ, VS+, VS- and ON/OFF lines, to avoid any unexpected interference during operation.  
(2) Be careful for drawing of SYNC-CLKOUT line, because CLKOUT lines have large amplitude of square wave form.  
SYNC  
VS-  
Cout  
for 1st Module  
1st Module  
GND  
Vout  
Vin  
Cin  
for 1st Module  
ON/OFF  
VS+  
SEQ  
+Trim  
PGOOD  
Share  
-Trim  
CLKOUT  
Rtrim  
SYNC  
2nd Module  
VS-  
GND  
Vout  
Cin  
for 2nd Module  
Vin  
RL  
R1  
Cout  
for 2nd Module  
ON/OFF  
VS+  
SEQ  
+Trim  
Vin  
PGOOD  
Rtrim  
Rtrim  
Share CLKOUT -Trim  
SYNC  
3rd Module  
+Trim  
Share  
PGOOD  
-Trim  
SEQ  
VS+  
ON/OFF  
Vout  
Cout  
for 3rd Module  
Vin  
GND  
Cin  
CLKOUT VS-  
for 3rd Module  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
ISO 9001 and 14001 REGISTERED  
This product is subject to the following operating requirements  
and the Life and Safety Critical Application Sales Policy:  
Refer to: http://www.murata-ps.com/requirements/  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to changewithout  
notice.  
© 2016 Murata Power Solutions,Inc.  
www.murata-ps.com/support  
MDC_OKY2-T/60-W12.A01 Page 15 of 15  

相关型号:

OKY2-T/60-W12P-C

DC-DC Regulated Power Supply Module,
MURATA

OKY2-T/60-W12PA-C

暂无描述
MURATA

OL-DANGLE-FRAME

No UV light radiation
EVERLIGHT

OL-RESET

RESET MODULE FOR MODEL 777
LITTELFUSE

OL-STRIPE

The light source of the OL-Stripe series is suggested the Everlight LED T5 Cobra light tube.
EVERLIGHT

OL-WEDGE

The light source of the OL-Wedge series is suggested the Everlight LED T5 Cobra light tube.
EVERLIGHT

OL1005E

Fixed Resistor, Carbon Film, 0.5W, 10ohm, 350V, 5% +/-Tol, -350,350ppm/Cel,
OHMITE

OL1025

Fixed Resistor, Carbon Film, 0.5W, 1000ohm, 350V, 5% +/-Tol
OHMITE

OL1025EA26

Fixed Resistor, Carbon Film, 0.5W, 1000ohm, 350V, 5% +/-Tol, 450ppm/Cel, Through Hole Mount, AXIAL LEADED, ROHS COMPLIANT
OHMITE

OL1025EA52

Fixed Resistor, Carbon Film, 0.5W, 1000ohm, 350V, 5% +/-Tol, 450ppm/Cel, Through Hole Mount, AXIAL LEADED, ROHS COMPLIANT
OHMITE

OL1025ER52

Fixed Resistor, Carbon Film, 0.5W, 1000ohm, 350V, 5% +/-Tol, 450ppm/Cel, Through Hole Mount, AXIAL LEADED, ROHS COMPLIANT
OHMITE

OL1055

Fixed Resistor, Carbon Film, 0.5W, 1000000ohm, 350V, 5% +/-Tol,
OHMITE