PKGS-00LDP1-R [MURATA]

Analog Circuit,;
PKGS-00LDP1-R
型号: PKGS-00LDP1-R
厂家: muRata    muRata
描述:

Analog Circuit,

文件: 总15页 (文件大小:144K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Reference only  
P.1 /15  
Product Specification for Reference Only  
Issued Date:  
Rev. :  
Jun. 05, 2013  
2
Part Description:  
S H O C K S E N S O R  
P K G S - 0 0 L D P 1 - R  
MURATA Part No.:  
The product specification in this sheet is for reference only.  
The contents of this specification are subject to change.  
You are requested to receive the latest specification and to return one  
copy of the specification to us with your receipt signature before going  
into mass production.  
Product engineering section  
Sensor Products Department  
Sensor Products Division  
Murata MFG. Co.,Ltd.  
Approved by  
Issued by  
Issued Date  
Drawing No.  
H. Kita  
T. Kawamoto  
Nov. 1, 2010  
Reference only  
Reference only  
P.2 /15  
SPECIFICATION for TRANSDUCER  
Part Number: PKGS-00LDP1-R  
1. Scope  
This product specification is applied to surface mountable acceleration sensors used for hard  
disk drive in a personal computer. Please contact us before using any of the products in the  
applications not described above.  
2. Part Number  
2-1 Murata Part Number  
:PKGS-00LDP1-R  
:
2-2 Customer Part Number  
2-3 Customer Drawing Number :  
3. Outline Drawing and Dimensions  
3-1 Appearance  
3-2 Dimensions  
3-3 Construction  
: As per paragraph 10.Appearance criteria.  
: See Figure 2.  
: A piezo ceramic element is stuck between two ceramic substrate.  
4. Characteristics  
(Temperature 25±3°C, unless otherwise noted)  
Parameter  
Test Condition  
Min.  
Typ.  
Max.  
Units  
Note  
1,2,5  
4-1 Electric Charge  
Sensitivity  
1kHz, 98.1m/s2(10G) applied  
in the direction of D axis at Fig.1  
-15%  
85.7  
{0.840}  
+15%  
fC/(m/s2)  
{pC/G}  
4-2 Insulation  
Resistance  
10V DC, after 1 min.  
500  
10000  
MΩ  
4-3 Non-Linearity  
% of the Full-Scale output at 490  
1%  
5%  
m/s2(50G). Range : ±50G  
4-4 Resonance  
Frequency  
17  
-3  
20  
0
kHz  
3
4-5 Inclined Angle of  
Sensitivity Axis  
Maximum deviation  
from initial value at +25°C.  
Maximum deviation  
from initial value at  
+25°C  
1Vrms,1kHz  
1kHz, 98.1m/s2(10G) applied in the  
direction of D axis at Fig.1  
+3  
Degree  
4-6 Electric Charge  
Sensitivity  
Temperature Drift  
4-7 Capacitance  
Ref. <reference Only>  
Voltage Sensitivity  
Ta:70°C  
Ta:0°C  
0%  
+4%  
+10%  
-5%  
-2.5%  
0%  
-30%  
770  
+30%  
pF  
{1.10}  
{mV/G}  
1,2,4  
Note:  
1. As measured with an applied acceleration in the direction of D at figure 1. In this case, positive  
voltage and electrical charge are generated at electrode B.  
2. 1[G] = 9.80665 [m/s2]  
3. Resonance frequency of inner bimorph element.  
4. Input impedance of measurement circuit is 10 MΩ(Zi), and amplified gain is 0 dB.  
5. f (femto)= 10-15  
MURATA MANUFACTURING CO., LTD  
Reference only  
P.3 /15  
Z
Y
D
0±1°  
Electrode A  
X
Polarity marking  
Electrode B  
Figure 1.  
Axis D : This axis is an acceleration applied direction, when electric charge sensitivity is checked.  
5. Standard land pattern  
Land pattern  
2.0  
3.4  
2.0  
Unit : mm  
6. Absolute Rating  
Apply voltage between electrode A and B : 10 Vp-p within 60 sec. max.  
Storage temperature range  
Operating temperature range  
: -40 to 85 °C  
: -40 to 85 °C  
MURATA MANUFACTURING CO., LTD  
Reference only  
P.4 /15  
7. Physical Characteristics  
Test Item  
Condition of Test  
Performance Requirements  
7-1 Mechanical  
Shock  
The transducer shall be measured after being No visible damage and the  
applied three impacts in plus and minus measured values shall meet  
directions of three mutually perpendicular Table 2  
planes.  
The shock is specified as 14700m/s2(1500G)  
half sine pulse of 0.5 ms duration.  
7-2 Vibration  
The transducer shall be measured after being  
applied vibration of amplitude of 1.5 mm with 10  
to 55 Hz band of vibration frequency to each of 3  
perpendicular directions for 2 hours.  
( 5 minutes × 24 cycles )  
7-3 Bend Strength The transducer is soldered onto the center of No visible damage and the  
PCB PCB (1.6 mm thickness) which is laid on the 2 measured values shall meet  
small supporters spaced 90 mm.  
Table 3  
PCB is deflected to 1 mm below from horizontal  
level by the pressing force with 20 × 10. R10  
stick. The force is supplied for 1 second, 5 times  
repeatably.  
Stick  
Load  
20 10  
PCB  
Deflection  
R10  
Part  
45  
±1 Off-Center  
45  
φ 5 Supporter  
Unit: mm  
7-4 Resistance to The transducer shall be mounted on PCB, then No visible damage and the  
Reflow  
measured after being applied following reflow measured values shall meet  
Soldering  
conditions.  
Table 2  
<Test flow>  
Pre-heating :  
60 to 150 sec. at 150 to 180 °C  
Heating :  
Within 60 sec. at 200 °C (or more)  
Within 30 sec. at 250 °C (or more)  
Peak Temperature:  
Within 10 sec. at 260 °C  
Shock sensor should be tested 2 times of this  
test flow.  
PCB size : 115 × 80 × 0.8 mm  
After being placed at ambient conditions for 8  
hours, the transducer shall be measured.  
7-5 Solderability  
7-6 Washability  
End terminals are immersed in rosin for  
5 seconds then immersed in soldering bath of be wet with solder.  
+230±5°C for 3±0.5 seconds.  
75% min. end terminals shall  
See Table 1  
No visible damage and the  
measured values shall meet  
Table 2  
MURATA MANUFACTURING CO., LTD  
Reference only  
P.5 /15  
Table 1 Wash  
Cleaning  
Alcohol  
Water  
Cleaning Water  
Solution  
Silicon  
(Techno care FRW)  
Solvent (Iso-propanol) (Tap water,  
Demineralized  
water)  
(Cleanthrough  
750H, Pine alpha  
100S )  
Item  
Temperature  
Difference: ΔT *1  
[ΔT = Component  
- Solvent]  
ΔT<100°C  
Condition  
(1) Ultrasonic  
Wash  
1 minute max. in above solvent at 60°C max.  
( Frequency : 28 kHz, Output : 20 W/L )  
(2) Immersion  
Wash  
5 minutes max. in above solvent at 60°C max.  
(3) Shower or  
Rinse Wash  
(4) Drying  
5 minutes max. in above solvent at 60°C max.  
1 to 5 minutes. by air blow at 80°C max.  
*1 ex. In case the component at 90°C immerses into cleaning solvent at 60°C,  
then ΔT = 30°C.  
Note(Wash)  
1.Please insure the component is thoroughly evaluated in your application circuit.  
2.The component may be damaged if it is washed with alkali cleaning solvent.  
3.Flux should be washed out before use.  
MURATA MANUFACTURING CO., LTD  
Reference only  
P.6 /15  
8. Environmental Characteristics  
Test Item  
Performance Requirements  
Condition of Test  
8-1 High  
After being placed in a thermal chamber with at The measured values shall  
Temperature +85±2°C for 1000 hours and then being placed at meet Table 2  
ambient conditions for 8 hours, the transducer shall be  
measured.  
8-2 Low  
After being placed in a thermal chamber with at The measured values shall  
Temperature -40±2°C for 1000 hours and then being placed at meet Table 2  
ambient conditions for 8 hours, the transducer shall be  
measured.  
8-3 Humidity  
After being placed in a humidity chamber with  
90 to 95% R.H. at +60±2°C for 500 hours  
and the being placed at ambient conditions for  
8 hours, the transducer shall be measured.  
The measured values shall  
meet Table 2  
8-4 Heat Shock  
After being kept at room temperature, the transducer The measured values shall  
shall be placed in a thermal chamber at temperature of meet Table 2  
-40°C.  
After 30 minutes at this temperature, the transducer  
shall be immediately placed in  
a
chamber at  
temperature of +85°C.  
After 30 minutes at this temperature, the transducer  
shall be returned to -40°C again.  
After 10 of the above cycles, the transducer shall be  
returned to ambient conditions where it shall remain for  
8 hours prior to being measured.  
Table 2  
Electric Charge Sensitivity  
±10% ( from initial value )  
±10% ( from initial value )  
Table 3  
Capacitance  
MURATA MANUFACTURING CO., LTD  
Reference only  
P.7 /15  
9. Dimensions and Indication  
Polarity marking  
6.4 ±0.2  
1.5 ±0.3  
1.2 +0.1/-0.2  
1.5 ±0.3  
Indication: Indication may lap  
over on the electrodes.  
Top  
Bottom  
Electrode A  
Electrode B  
Unit: mm  
1.5 ±0.3  
1.5 ±0.3  
Figure 2. Dimensions  
Indication contents  
Part number code⋅⋅⋅⋅⋅⋅⋅⋅ A  
M
Manufacturing company mark⋅⋅⋅⋅⋅⋅⋅⋅ C  
Monthly code⋅⋅⋅⋅⋅⋅⋅⋅Monthly code based on EIAJ-0901  
Part number code  
Dot  
Monthly code  
Manufacturing  
company mark  
MURATA MANUFACTURING CO., LTD  
Reference only  
P.8 /15  
10. Appearance criteria  
10-1. Crack, Chip and Partial lack of electrode  
B-part  
(Along with short edge)  
A-part  
(Along with long edge)  
Electrode  
Electrode for  
Polarity marking  
c
d
a
b
Corner  
(*1) Any chips which is covered by electrode are judged as good.  
If crack or chip exist at corners, apply the above B-part standard.  
In case crack or chip reaches internal cavity, it is judged as failure even if length [b], [d] and width  
[a], [c] are met this specification.  
If there are two or more chips on B part, total length of [d] should be < 1.2mm  
Criteria table for A part  
Unit [mm]  
0 < b < 0.4  
0.4 < b  
G
0 < a < 1.2  
1.2 < a  
G
G
NG  
Criteria table for B part  
Unit [mm]  
0 < d < 0.4  
0.4 < d < 1.2  
1.2 < d  
G
0 < c < 0.4  
G
G
G
G
G
0.4 < c < 1.2  
1.2 < c  
NG  
NG  
NG  
MURATA MANUFACTURING CO., LTD  
Reference only  
P.9 /15  
10-2. Electrode peeling and delamination  
Apply A-part standard to top and bottom electrode including polarity marking.  
Apply B-part standard to two-end electrode.  
A-part  
(Top, bottom,  
d
b
polarity marking)  
c
a
B-part  
(Two-end)  
Criteria table for A part  
Unit [mm]  
1.0 < b  
0 < b < 0.4  
0.4 < b < 1.0  
0 < a < 0.4  
G
G
G
G
G
G
0.4 < a < 1.0  
1.0 < a  
NG  
NG  
NG  
Criteria table for B part  
Unit [mm]  
0 < d < 0.4  
0.4 < d  
G
0 < c < 1.0  
1.0 < c  
G
G
NG  
MURATA MANUFACTURING CO., LTD  
Reference only  
P.10 /15  
10-3. Electrode protrusion and bridge  
Top view  
Electrode for  
polarity marking  
B-part  
A-part  
c
h
b
a
Side view  
C-part  
d
M
[A-part]  
If electrode protrusion reaches opposite electrode, it should be failure.  
The same criteria are applied on the bottom electrode.  
Criteria table for A part  
Unit [mm]  
0 < b < 0.4  
0.4 < b  
G
0 < a < 1.2  
1.2 < a  
G
G
NG  
[B-part]  
Criteria table for B part  
Unit [mm]  
c < h  
h < c  
NG  
G (*1)  
(*1) In case electrode protrude reaches to polarity marking, it should be good.  
[C-part]  
Criteria table for C part  
Unit [mm]  
M+ 1.2 < d  
NG  
d < M+ 1.2  
G
MURATA MANUFACTURING CO., LTD  
Reference only  
P.11 /15  
10-4. Position of connection electrode  
Top view  
Connection electrode  
a > 0  
a
It is judged as good regardless of the position of connection electrode  
Unit [mm]  
a > 0  
G
MURATA MANUFACTURING CO., LTD  
Reference only  
P.12 /15  
11. Taping Method  
11-1 The tape for transducer shall be would clockwise. The feeding holes shall be to the right side  
as the tape is pulled toward the user.  
11-2 A reel shall contain 2,000 pcs of transducers and be clearly marked with part number,  
quantity, inspection number.  
4.0 ±0.1  
+0.1  
φ 1.5 -0.0  
2.0 ±0.1  
+0.3  
4.0 ±0.1  
196 to 686mN (20 to 70gf)  
φ 1.5 -0.0  
3.2 ±0.1  
300mm/min.  
Cover Tape  
(3° )  
10°  
Unit: mm  
Direction of Feed  
Figure.3 Dimension of Plastic Tape  
Trailer  
110 to 190  
100 Min. weld  
Leader  
Cover Tape  
160 Min.  
400 to 560  
+0.5  
2 –0.2  
φ13 ±0.5  
Unit : mm  
+1.0  
12.5 –0.0  
19.5 Max  
Figure.4 Dimension of Plastic Reel  
MURATA MANUFACTURING CO., LTD  
Reference only  
P.13 /15  
12.  
Caution (Application, Fail-safe)  
12-1.Application Limitations  
This product, the PKGS type shock sensor, has been designed for hard-disk drive applications,  
used in personal computers and consumer audio-visual equipments.  
Please contact Murata before using this product in the applications listed below, which require  
especially high reliability for the prevention of defects which might directly cause damage to the  
third party's life, body or property, or when this product is intended for use in applications other  
than those specified in this data sheet. We shall not be liable for any claims on the product in  
case it is used in the listed applications below, without contacting us.  
(1) Cellular phone  
(2) Automotive equipment other than the above mentioned  
(3) Outside use equipment  
(6) Under sea equipment  
(9) Transportation equipment (vehicles, trains, ships, etc.)  
(4) Aircraft, Avionics equipment  
(7) Power plant control equipment  
(5) Aerospace equipment  
(8) Medical equipment  
(10) Industrial equipment  
(11) Traffic signal equipment (12) Disaster prevention / crime prevention equipment  
(13) Safety device / system (14) Military equipment (regardless of direct/indirect use)  
(15) Applications of similar complexity and/or reliability requirements to the applications listed  
in the above.  
12-2.Fail-safe  
Be sure to provide an appropriate fail-safe function on your product to prevent damage that may  
be caused by the abnormal function or the failure of our product.  
13.  
Caution (Handling)  
1) This product may be degraded by electrostatic discharge. We would suggest countermeasures  
against electrostatic discharge, before handling this product.  
2) Please evaluate this product in your product; with it mounted to a Printed Circuit Board (PCB) or  
similar. We recommend that this product not be repeatedly mounted on or removed from a PCB  
by soldering, because of the possibility of degradation due to excessive heating to this product or  
electrostatic discharge (in case electrostatic discharge is not guarded against).  
14.  
Caution (Storage condition and usage environment)  
1) Maximum storage period is for 6 months under the condition of 30°C and 70%RH before PCB  
mounting. If this product is kept in an especially high humidity environment, the product may  
degrade because of decreased insulation resistance value due to such conditions.  
2) Please do not store and do not use this product in conditions that differ greatly from atmospheric  
pressure, such as a vacuum space, a high mountain, water, and so on. A pressure cooker test is  
not applicable for this product.  
3) Please do not expose this product to dust, oil, corrosive gas, acid, or alkali. This product may be  
degraded if exposed.  
15.  
Caution (Design)  
1)Please use a charge amplifier circuit. This specification is only valid for use with charge amplifiers.  
For instance, if you use a voltage amplifier circuit that is used with this product, we shall not be  
liable for any claims.  
2)Please do not apply DC bias voltage to this product, because it causes degradation of insulation  
resistance value. Please try to keep minimizing the input bias current at front-end of amplifier  
circuit as well.  
3)Please thoroughly evaluate this product for noise immunity. Noise, coming from the product (EMI)  
and/or generated by signal lines on PCB or other mechanical device (like a spindle motor), may  
result in the miss-operation or the non-operation of this product.  
4)Please thoroughly evaluate this product in terms of mechanically accelerated transmission system,  
because this product may detect unexpected acceleration that is transmitted through PCB and/or  
through the frame of your product. Mechanical resonance on your product or individual vibration  
frequency of installed components/devices may create mutual interference, and it may result in  
incorrect measurement by the sensor.  
MURATA MANUFACTURING CO., LTD  
Reference only  
P.14 /15  
5)Please do not apply excessive strain force or shock to this product that deviates from the  
conditions in this specification, because mechanical failure or damage could occur.  
6)Please thoroughly evaluate this product in your manufacturing if you will use any conformal coating  
or potting process. These processes (for instance, in case resin type of material is used) could  
result in package breaks, due to heat shrink. Also, humidity that remains inside of the case, may  
affect circuit operation due to decreased insulation resistance value.  
7)Physical and environmental characteristics for this product are described in this specification.  
Please consider these characteristics in evaluating this part in your product.  
8)Please carefully design the application’s housing to minimize dew and humidity. An amplifier circuit  
would have high impedance, 50M ohm for instance, but this value may decrease under a high  
humid environment. Due to this; you may not be able to see the intended performance from your  
circuit design, unless you consider theses factors in your product design.  
9)Please do not use this product in the presence of radiation rays or cosmic rays.  
10)Please do not use this product in the presence of high electromagnetic fields.  
11)Please consider the possibility of unexpected output signal-level generated by sharp temperature  
change. Please evaluate this product under all expected environmental conditions.  
recommend a fail-safe function to compensate for any unexpected signal levels.  
We  
12)Pyroelectric noise may be seen on the output signal of this product, where there is a temperature  
variation (delta-t) around the product. Delta-t may likely occur by airflow that is generated by a  
cooling fan that is often used in a computer. If your application requires a very small acceleration  
resolution, less than 0.1G with 50Hz or less for instance, we would suggest shutting off the airflow  
for increased accuracy in sensor detection.  
13)This product is very sensitive to bending stress occurring on PCB, therefore please locate the  
sensor in an area on the PCB that is unaffected by bending stresses.  
16.  
Caution (Mounting)  
16-1. Reflow soldering  
1)Please use the standard footprint as shown in the specification. If you use a different one, we shall  
not be liable for any claims.  
2)Please follow soldering conditions described in the specification. This product can permanently  
stop operating if the piezoelectric characteristic is decreased due to excessive heating.  
3)Please follow the recommended washing conditions, as described in the specification.  
4)Please make sure to evaluate the soldering condition with this product mounted on your PCB.  
<Reflow temperature profile (reference only)>  
Peak Temp.  
245 °C max.  
230  
Gradual cooling  
in air  
Pre-heating  
in air  
180  
150  
100  
60 to 120 sec.  
Within 30 sec.  
16-2. Soldering Iron  
Use iron (3mm diameter or less, 45W max.) and iron temp should be 300°C max.  
within 3 sec. at only one point. Please take care to avoid soldering iron from touching the  
product directly.  
MURATA MANUFACTURING CO., LTD  
Reference only  
P.15 /15  
17.  
Note  
1)Please make sure that the final product has been evaluated to all your product’s specifications,  
with this product mounted inside.  
2)All the items and parameters in this product specification have been prescribed on the premise that  
our product is used for the purpose, under the conditions, and in the environment agreed upon  
between us. You are requested not to use our product deviating from this product specification.  
3)We consider it inappropriate to include any terms or conditions with regard to the business  
transactions in the product’s specification, drawing, or other technical document. Therefore, if your  
technical document includes any of the above items, such as warranty clause, product liability  
clause, or intellectual property infringement liability clause, they will be deemed to be invalid.  
MURATA MANUFACTURING CO., LTD  

相关型号:

MURATA
MURATA
MURATA

PKGS-25NBP1-R

operating temperature range
MURATA
MURATA
MURATA
MURATA
MURATA
MURATA
MURATA
MURATA