Q-ClassConverters
QHS35-033 Model
OBSOLETE PRODUCT
Model
3.3V
Units
Parameter
3.25 – 3.35
0.1, 0.2
3.20 – 3.40
95-110
10
Output Voltage Setpoint
Vdc
% Vo
Line/Load Regulation
Output total regulation
Output adjust
Max
Max
Vdc
%Vo,nom
%Vo,nom
mVp-p
Remote-sense Comp.
Output Ripple & Noise (note 2)
Output Current
100
0.1
35
Min
A
A
Max
90.5
10,000
165
Efficiency (48V, Full load, 25C)
External Capacitance
Typ
%
μF
Max
Transient Response (typ) (note3)
mV
μs
ΔVo
300
Ts
25% step, 1A/μs
Over-voltage trip point -static
4.2 – 4.6
44
V
A
(latching)
-dynamic
max
Typ
Over-current trip point (non-latching)
All specifications at Ta=25C, Vin=48V, 300 LFM unless otherwise specified
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
1
QHS35-6201011510_D01_21/04/08
Q-ClassConverters
QHS35-033 Model
Parameter
Conditions
Min.
36
Typ.
48
Max.
Units
Input
Input Voltage (Vin)
75
Vdc
Reflected Ripple Current (see note 1)
Input Current
Inrush Transient
--
--
10
4
0.2
mA p-p
A
A2s
Undervoltage Lockout
Turn-on
Turn-off
Turn-off
Turn-on
32
31
76
75
35
34
80
79
Vdc
Vdc
Vdc
Vdc
Over-voltage lockout
Isolation
Input-Output
Resistance; input-output
1500
10
Vdc
Mohm
Temperature
Operating Ambient
Storage
-40
-40
--
--
85
°C
°C
125
Protection
Over-Temperature
Measured on PCB
--
120
--
°C
Physical Information Dimensions
2.28”L x 1.45” W x 0.47”H (57.91 x 36.83 x 11.8 mm)
MTBF(Bellcore)
Safety
Calculated at 40C ambient, 100% Iomax: 1,000,000 Hrs
The QHS35-033 complies with IEC/EN/CSA 60950 safety requirements, providing basic
insulation, input to output. c-UL-us (US & Canada) recognized. TUV (Bauart) approved.
QHS35-033 Thermal Derating
QHS35-033 Thermal Derating
TJ= 120ºC Airflow Parallel To +Vin to -Vin
TJ = 120ºC Ver. Orientation for 0LFM, Hor. Orientation for 50LFM, Vin to Vout
Airflow
40
35
30
25
20
15
10
35
30
25
20
15
10
5
0 LFM
100 LFM
200 LFM
300 LFM
400 LFM
50 LFM (Q404)
50 LFM (U302)
Poly. (50 LFM
(Q404))
Poly. (100
LFM)
Poly. (50 LFM
(U302))
0
20
30
40
50
60
70
80
90
20
30
40
50
60
70
80
90
Ambient Temperature [ºC]
Ambient Temperature [ºC]
www.murata-ps.com/support
2
QHS35-6201011510_D01_21/04/08
Q-ClassConverters
QHS35-033 Model
Pin Assignments
Pin #
Description
Vin (+)
Enable (note 4)
Vin(-)
Pin #
Description
Vout(-)
Sense -
Vo adj
Pin #
7
8
Description
Sense +
Vo (+)
1
2
3
4
5
6
Notes:
1. Input Reflected Ripple is specified when measured with the filter shown below.
is
ic
L2
Vin
12uF
DC-DC
Converter
220uF,
ESR<0.1 Ohms
@ 100kHz
33uF,
ESR<0.7 Ohms
@ 100kHz
RTN
2. Output Ripple and noise is specified when measured with a 10uF tantalum and a 1uF ceramic
capacitor at the converter output pins.
3. Transient response is specified without a capacitor at the output of the converter.
4. Enable pin: 2.5V < enable high < 15V, OV < enable low <0.8V. Internal pull-up is 5V @ >
50Kohm.
5. For thermal measurement location (TML) refer to mechanical drawing.
www.murata-ps.com/support
3
QHS35-6201011510_D01_21/04/08
Q-ClassConverters
QHS35-033 Model
QHS35-033 Efficiency
92.0
91.0
90.0
89.0
88.0
87.0
86.0
Vin 36V
Vin 48V
Vin 75V
Output Current (A)
Output Ripple and Noise
(Vin=48V, Io=35A, 100Mz BW)
Note 2
Output Voltage Response to Step Load (25.5A, -17.5A
load step, di/dt = 1A/us, Tamb=25C, Vin=48V)
Output Voltage Response to Step Load (25.5A, +17.5A
load step, di/dt = 1A/us, Tamb=25C, Vin=48V)
www.murata-ps.com/support
4
QHS35-6201011510_D01_21/04/08
Q-ClassConverters
QHS35-033 Model
Input Reflected Ripple (Vin=48V, Iout=35A)
Turn-on from Enable
Turn-on, Startup Inhibit Delay
Vin=48V, Iout =35A, Cout=10,000uF, Enable tied to
Vi(-)
CH1: Vin 20V/div
Vin=48V, Iout =35A, Cout=10,000uF
CH1: Vout 1V/div time base 5ms/div
CH2 Enable pin 2V/div
CH2: Vout @ 1V/div time base 20ms/div
Pre-Bias Startup Characteristic
Turn-Off Characteristic
Vin = 48V Pre-bias of 2.2V
Vin = 48V Iout = 35A 10mF output capacitance
www.murata-ps.com/support
5
QHS35-6201011510_D01_21/04/08
Q-ClassConverters
QHS35-033 Model
Conducted EMI Characteristic with external
filter as specified
QHS35-033 Trim-up and Trim-down Resistance
1000
100
10
Rup
Rdow n
Delta %
0
2
4
6
8
10
Safety considerations
The QHS35-033 complies with IEC/EN/CSA 60950 safety requirements, providing basic insulation, input to output.
c-UL-us (US & Canada) recognized. An external input fuse, rated at 5A to 20/30A, fast-blow type, must be used to meet
the above requirements. The fuse will isolate the failed converter from the input source and protect the distribution
wiring from overheating. The output of the converter is considered to remain within SELV limits when the input to the
converter meets SELV requirements
The converters are designed to meet UL 94V-0 flammability ratings.
www.murata-ps.com/support
6
QHS35-6201011510_D01_21/04/08
Q-ClassConverters
QHS35-033 Model
Part Number Designations
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2012 Murata Power Solutions, Inc.
www.murata-ps.com/support
7
QHS35-6201011510_D01_21/04/08
相关型号:
©2020 ICPDF网 联系我们和版权申明