UCE-3.3/30-D48NL1-C [MURATA]

DC-DC Regulated Power Supply Module, 1 Output, 99W, Hybrid, PACKAGE-8;
UCE-3.3/30-D48NL1-C
型号: UCE-3.3/30-D48NL1-C
厂家: muRata    muRata
描述:

DC-DC Regulated Power Supply Module, 1 Output, 99W, Hybrid, PACKAGE-8

文件: 总17页 (文件大小:930K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
LAST TIME BUY: AUGUST 31, 2014. CLICK HERE FOR OBSOLESCENCE NOTICE OF FEBRUARY 2014.  
UCE Series  
s
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
FEATURES  
  
Industry standard eighth-brick pinout  
and package  
Typical unit  
  
Low profile 0.4" height with 0.9" x 2.3"  
outline dimensions  
For efficient, fully isolated DC power in the smallest space, the UCE  
open frame DC-DC converter series fit in industry-standard “eighth  
brick” outline dimensions and mounting pins (on quarter-brick pinout).  
  
36 to 75 Vdc input range (48V nominal)  
NOT RECOMMENDED  
  
Fully isolated, 2250 Vdc (BASIC)  
insulation  
PRODUCT OVERVIEW  
  
Outstanding thermal performance  
and derating  
FOR NEW DESIGNS  
Units are offered with fixed output voltages from  
1.5 to 12 Volts and currents up to 30 Amps. UCEs  
operate over a wide temperature range (up to +85  
degrees Celsius at moderate airflow) with full rated  
power. Interleaved synchronous rectifier topology  
yields excellent efficiency over 90% and no reverse  
output conduction.  
UCEs achieve these impressive mechanical and  
environmental specs while delivering excellent  
electrical performance in a through-hole package.  
Overall noise is typically 50 mV pk-pk (low voltage  
models) with fast step response. These converters  
offer tight output regulation and high stability even  
with no load. The unit is fully protected against  
input undervoltage, output overcurrent and short  
circuit. An on-board temperature sensor shuts  
down the converter if thermal limits are reached.  
“Hiccup” output protection automatically restarts  
the converter when the fault is removed.  
  
Extensive self-protection and short  
circuit features with no output reverse  
conduction  
A convenient remote On/Off control input enables  
phased startup and shutdown in multi-voltage ap-  
plications. To compensate for longer wiring and to  
retain output voltage accuracy at the load, UCEs em-  
ploy a Sense input to dynamically correct for ohmic  
losses. A trim input may be connected to a user’s  
adjustment potentiometer or trim resistors for output  
voltage calibration. The UCE will tolerate substantial  
capacitive loading for bypass-cap applications.  
UCEs include industry-standard safety certifica-  
tions and BASIC I/O insulation provides input/output  
isolation to 2250V. Radiation emission testing is  
performed to widely-accepted EMC standards.  
  
On/Off control, trim and sense functions  
  
Interleaved synchronous rectification  
yields high efficiency over 90%  
  
Fully protected against temperature and  
voltage limits  
  
RoHS-6 or RoHS-5 compliant  
  
Certified to UL/EN/IEC 60950-1 and  
CAN/CSA C22.2 No. 60950-1, 2nd Edition  
safety approvals  
SIMPLIFIED BLOCK DIAGRAM  
+SENSE  
(7)  
+VIN  
(1)  
+VOUT  
(8)  
SWITCH  
CONTROL  
−VOUT  
(4)  
–VIN  
(3)  
−SENSE  
(5)  
INPUT UNDERVOLTAGE, INPUT  
OVERVOLTAGE, AND OUTPUT  
OVERVOLTAGE COMPARATORS  
PULSE  
TRANSFORMER  
PWM  
CONTROLLER  
OPTO  
ISOLATION  
REFERENCE &  
ERROR AMP  
V
OUT TRIM  
(6)  
REMOTE  
ON/OFF  
CONTROL  
(2)  
Typical topology is shown.  
Figure 1. Simplified Block Diagram  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com/support  
MDC_UCE.D01 Page 1 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE  
Output  
Input  
Ripple & Noise  
IIN, no IIN, full  
(mVp-p)  
Regulation (max.)  
Efficiency  
Min. Typ.  
Package  
Case Pinout  
VOUT  
IOUT Power  
VIN Nom. Range  
(V) (V)  
load  
load  
(A)  
Model Family  
(V) (A)  
(W)  
Typ.  
Max.  
Line  
Load  
(mA)  
OBSOLETE  
OBSOLETE  
OBSOLETE  
OBSOLETE  
OBSOLETE  
OBSOLETE  
OBSOLETE  
1.2  
1.5  
1.5  
1.8  
2.5  
3.3  
3.3  
5
25  
20  
40  
30  
20  
15  
30  
10  
20  
4.2  
8.3  
10  
30  
Please contact Murata Power Solutions for further information.  
0.3% 48 36-75 50 0.72 85%  
Please contact Murata Power Solutions for further information.  
UCE-1.2/25-D48  
UCE-1.5/20-D48  
UCE-1.5/40-D48  
UCE-1.8/30-D48  
UCE-2.5/20-D48  
UCE-3.3/15-D48  
UCE-3.3/30-D48  
UCE-5/10-D48  
UCE-5/20-D48  
UCE-12/4.2-D48  
UCE-12/8.3-D48  
UCE-12/10-D48  
*
*
*
*
*
*
*
30  
50  
30  
100  
0.15%  
87%  
C56 P32  
60  
54  
45  
50  
1.28  
1.14  
1.15  
2.27  
1.15  
2.25  
1.14  
2.31  
2.78  
87%  
88%  
86%  
89%  
88%  
90%  
88%  
91%  
80  
50  
0.125%  
0.1%  
0.25%  
0.2%  
49.5  
99  
90%  
50  
60  
30  
100  
60  
91%  
50  
48  
36-75  
90.5%  
92.5%  
92%  
C56 P32  
5
100  
50.4  
99.6  
120  
30  
OBSOLETE  
OBSOLETE  
12  
12  
12  
150  
0.125%  
0.25%  
50  
*
300  
86%  
200  
90%  
*
Please refer to the model number structure for additional ordering part numbers and options.  
http://www.murata-ps.com/en/products/obsolete-and-not-recommended.html  
LAST TIME BUY: AUGUST 31, 2014. CLICK HERE FOR OBSOLESCENCE NOTICE OF FEBRUARY 2014.  
*
PART NUMBER STRUCTURE  
U CE - 3.3 / 30 - D48 N B H Lx - C  
Output Configuration:  
RoHS Hazardous Materials compliance  
C = RoHS6 (does not claim EU RoHS exemption 7b–lead in solder), standard  
Y = RoHS5 (with lead), optional, special quantity order  
U = Unipolar/Single  
OBSOLETE  
*
(Through-hole packages only)  
Pin Length Option  
Eighth-Brick Package  
Blank = Standard pin length 0.180 inches (4.6mm)  
L1 = Pin length 0.110 inches (2.79mm)*  
L2 = Pin length 0.145 inches (3.68mm)*  
Nominal Output Voltage  
*Special quantity order is required;  
no sample quantities available.  
Conformal coating (optional)  
Blank = no coating, standard  
Maximum Rated Output  
H = Coating added, optional, special quantity order  
Current in Amps  
Baseplate (optional, not available on some models)  
Blank = No baseplate, standard  
Input Voltage Range:  
B = Baseplate installed, optional, special quantity order  
D48 = 36-75V,  
48V nominal  
Note: Some model combinations may not be  
available. Contact Murata Power Solutions for  
availability.  
On/Off Control Logic  
N = Negative logic, standard  
P = Positive logic, optional  
As of September 2014, ONLY the following part numbers will be available: UCE-5/10-D48N-C; UCE-5/10-D48NB-C;  
UCE-5/20-D48N-C; UCE-5/20-D48NB-C; UCE-12/10-D48N-C; UCE-12/10-D48NB-C  
Product Adaptations  
Murata Power Solutions offers several variations of our core product family.  
These products are available under scheduled quantity orders and may also  
include separate manufacturing documentation from a mutually agreeable  
Product Specification. Since these product adaptations largely share a common  
parts list and similar specifications and test methods with their root products,  
they are provided at excellent costs and delivery. Please contact Murata Power  
Solutions for details.  
As of this date, the following products are available:  
UCE-3.3/30-D48NHL2-Y  
OBSOLETE  
UCE-12/4.2-D48NHL2-Y  
*
These models are all negative On/Off logic, no baseplate, conformal coating  
added, 3.68mm pin length, and RoHS-5 hazardous substance compliance (with  
lead).  
www.murata-ps.com/support  
MDC_UCE.D01 Page 2 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
FUNCTIONAL SPECIFICATIONS  
INPUT CHARACTERISTICS  
Under- Reflected  
Remote On/Off Control  
Start-up  
threshold  
Min.  
voltage (back)  
Shut- Ripple  
down Current  
Internal Reverse  
Input Filter Polarity  
Output  
Short  
Circuit  
(mA)  
Model Family  
Inrush  
Transient  
A2sec  
Low Line Standby  
(VIN=min.) Mode  
Positive Logic Negative Logic  
Current  
(mA)  
Type  
Protection  
“P” Model  
Suffix  
“N” Model  
Suffix  
(A)  
(V)  
(mA)  
(A)  
(mA)  
32  
32.5  
32  
0.97  
1.72  
1.53  
1.54  
3.06  
1.53  
3.00  
1.52  
3.07  
3.70  
UCE-1.5/20-D48  
UCE-1.8/30-D48  
UCE-2.5/20-D48  
UCE-3.3/15-D48  
UCE-3.3/30-D48  
UCE-5/10-D48  
UCE-5/20-D48  
UCE-12/4.2-D48  
UCE-12/8.3-D48  
UCE-12/10-D48  
34  
L-C  
OFF=Ground  
pin to +1V max.  
ON=open or  
OFF=open or  
+2.5V to  
+15V max.  
32  
50-150,  
model  
dependent  
10-30,  
model  
dependent  
1-10,  
model  
dependent  
32  
0.05  
None, install  
external fuse  
1.0  
A2sec  
34.5  
34  
32  
Pi  
Pi  
+3.5 to +15V ON=Ground pin to  
31.5  
max.  
+0.8V max.  
34  
32  
L-C  
500  
OUTPUT CHARACTERISTICS  
VOUT  
Current Limit  
Inception  
98% of Vout,  
after warmup  
A
Capacitive  
Remote  
Sense  
Ripple/  
Noise  
Accuracy Loading Max. Low  
50% Load ESR <0.02Ω Max. Adjustment Temperature Minimum Compen- (20 MHz  
Line/Load  
Model Family  
UCE-1.5/20-D48  
UCE-1.8/30-D48  
UCE-2.5/20-D48  
UCE-3.3/15-D48  
UCE-3.3/30-D48  
UCE-5/10-D48  
UCE-5/20-D48  
UCE-12/4.2-D48  
UCE-12/8.3-D48  
UCE-12/10-D48  
% of VNOM  
μF  
Range  
Coefficient  
Loading  
sation bandwidth) Regulation Efficiency  
24.5  
36  
10,000  
32  
24  
–10 to  
+10% of  
Vnom.  
0.02% of  
Vout range  
per °C  
35  
No minimum  
load  
1%  
+10%  
See ordering guide  
1000  
15.  
10,000  
23 min.  
5.5  
1000  
12  
13  
ISOLATION CHARACTERISTICS  
Input to Output  
Input to  
baseplate  
Min.  
V
Baseplate to output  
Isolation  
Resistance  
MΩ  
Isolation  
Capacitance  
pF  
Min.  
V
Min.  
V
Model Family  
UCE-1.5/20-D48  
UCE-1.8/30-D48  
UCE-2.5/20-D48  
UCE-3.3/15-D48  
UCE-3.3/30-D48  
UCE-5/10-D48  
UCE-5/20-D48  
UCE-12/4.2-D48  
UCE-12/8.3-D48  
UCE-12/10-D48  
Isolation Safety Rating  
100  
10  
2250  
1500  
1500  
1000  
Basic Insulation  
100  
www.murata-ps.com/support  
MDC_UCE.D01 Page 3 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
FUNCTIONAL SPECIFICATIONS, CONTINUED  
MISCELLANEOUS CHARACTERISTICS  
Overvoltage  
Protection12  
(V) Via  
Operating  
Temperature Range  
Operating  
PCB  
Storage  
Thermal  
Short  
Temperature Protection/ Circuit magnetic Short Circuit  
Relative  
Calculated  
MTBF4  
with derating  
(°C)  
Temperature  
(no derating)  
Range  
(°C)  
Shutdown Current feedback  
Protection Short Circuit  
Method  
Humidity  
Model Family  
UCE-1.5/20-D48  
UCE-1.8/30-D48  
UCE-2.5/20-D48  
UCE-3.3/15-D48  
UCE-3.3/30-D48  
UCE-5/10-D48  
(ºC)  
(A)  
(V)  
Duration16 (non-condensing)  
1.95  
TBC  
2.8 V. max  
3
Current  
Continuous,  
output  
1.8 M HRS  
2.4 M HRS  
120  
5
limiting,  
−40 to +110  
(model  
4.25  
hiccup  
shorted  
−55 to  
+125  
−40 to +85  
autorestart.  
Remove  
to  
to +85°C/85%  
2.6 M HRS  
2.7 M HRS  
TBC  
ground.  
No dam-  
age.  
dependent)  
110  
125  
0.5  
5
7 max.  
UCE-5/20-D48  
overload for  
recovery.  
UCE-12/4.2-D48  
UCE-12/8.3-D48  
UCE-12/10-D48  
14.5  
2.4 M HRS  
ABSOLUTE MAXIMUM RATINGS  
DYNAMIC CHARACTERISTICS  
Dynamic Load  
Start-up Time  
Remote On/  
Input Voltage:  
Response  
(50-75-50%  
load step) to 1%  
of final value,  
μSec  
Continuous:  
48 Volt input models  
Transient (100 mSec. Max.)  
48 Volt input models  
75 Volts  
VIN to VOUT  
regulated  
(Max.)  
Off to VOUT  
regulated  
(Max.)  
Switching  
Frequency  
KHz  
100 Volts  
+15 Volts  
On/Off Control  
Model Family  
UCE-1.5/20-D48  
UCE-1.8/30-D48  
UCE-2.5/20-D48  
UCE-3.3/15-D48  
UCE-3.3/30-D48  
UCE-5/10-D48  
(See note 1)  
mSec  
Input Reverse Polarity Protection  
Output Overvoltage Protection  
None, install external fuse.  
100  
150  
100  
200  
50  
50  
10  
50  
50  
15  
50  
10  
60  
50  
60  
50  
10  
50  
50  
10  
50  
10  
60  
50  
60  
480  
400  
350  
480  
380  
400  
330  
Magnetic feedback.  
See specifications.  
Output Current  
Current-limited. Devices can  
withstand sustained short circuit  
without damage.  
100  
100 max.  
30  
Storage Temperature  
Lead Temperature  
–40 to +125°C.  
UCE-5/20-D48  
See soldering guidelines.  
UCE-12/4.2-D48  
UCE-12/8.3-D48  
UCE-12/10-D48  
Absolute maximums are stress ratings. Exposure of devices to greater than any of these  
conditions may adversely affect long-term reliability. Proper operation under conditions  
other than those listed in the Performance/Functional Specifications Table is not implied  
or recommended.  
50  
200  
50  
www.murata-ps.com/support  
MDC_UCE.D01 Page 4 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
FUNCTIONAL SPECIFICATIONS, CONTINUED  
PERFORMANCE SPECIFICATION NOTES  
(1) All models are tested and specified with external 1||10 μF ceramic/tantalum output capaci-  
tors and no external input capacitor. All capacitors are low ESR types. These capacitors are  
necessary to accommodate our test equipment and may not be required to achieve specified  
performance in your applications. All models are stable and regulate within spec under no-load  
conditions.  
(7) The outputs are not intended to sink appreciable reverse current. This may damage the  
outputs.  
(8) Output noise may be further reduced by adding an external filter. See I/O Filtering and Noise  
Reduction.  
(9) All models are fully operational and meet published specifications, including “cold start” at  
–40ºC.  
General conditions for Specifications are +25 deg.C, VIN = nominal, VOUT = nominal, full load.  
Adequate airflow must be supplied for extended testing under power.  
(10) Regulation specifications describe the deviation as the line input voltage or output load  
current is varied from a nominal midpoint value to either extreme.  
(2) Input Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering  
is CIN = 33 μF, 100V tantalum, CBUS = 220 μF, 100V electrolytic, LBUS = 12 μH.  
(11) Alternate pin length and/or other output voltages are available under special quantity order.  
(3) Note that Maximum Power Derating curves indicate an average current at nominal input  
voltage. At higher temperatures and/or lower airflow, the DC-DC converter will tolerate brief  
full current outputs if the total RMS current over time does not exceed the Derating curve. All  
Derating curves are presented at sea level altitude. Be aware of reduced power dissipation  
with increasing density altitude.  
(12) Output overvoltage is non-latching. When the overvoltage fault is removed, the converter  
will immediately recover.  
(13) Do not exceed maximum power specifications when adjusting the output trim.  
(14) At zero output current, the output may contain low frequency components which exceed  
the ripple specification. The output may be operated indefinitely with no load.  
(4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case  
3, ground fixed conditions, Tpcboard=+25 deg.C, full output load, natural air convection.  
(15) If reverse polarity is accidentally applied to the input, a body diode will become forward bi-  
ased and will conduct considerable current. To ensure reverse input protection with full output  
load, always connect an external input fuse in series with the +VIN input.  
(5) The On/Off Control is normally controlled by a switch. But it may also be driven with exter-  
nal logic or by applying appropriate external voltages which are referenced to Input Common.  
The On/Off Control Input should use either an open collector or open drain transistor.  
(6) Short circuit shutdown begins when the output voltage degrades approximately 2% from  
the selected setting.  
PHYSICAL CHARACTERISTICS  
Outline dimensions  
Pin material  
See mechanical specs (below)  
Copper alloy  
Pin diameter  
Pin finish  
0.04/0.062" (1.016/1.524mm)  
Nickel underplate with gold overplate  
0.67 ounces (19 grams)  
UCE-1.5/20-D48  
UCE-1.8/30-D48,  
UCE-2.5/20-D48  
UCE-5/10-D48  
0.71 ounces (20 grams)  
Weight  
UCE-5/20-D48  
UCE-12/4.2-D48  
UCE-3.3/15-D48  
1 ounce (28 grams)  
UCE-3.3/30-D48, UCE-12/8.3-D48, UCE-12/10-D48  
0.81 ounces (23 grams)  
Meets EN55022/CISPR22 (requires external filter)  
Electromagnetic interference (external filter required)  
Safety  
Certified to UL/cUL 60950-1, CSA-C22.2 No. 60950-1, IEC/EN 60950-1, 2nd Edition  
SOLDERING GUIDELINES  
Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceed-  
ing these specifications may cause damage to the product. Your production environment may differ; therefore please thoroughly review these guidelines with  
your process engineers.  
Wave Solder Operations for through-hole mounted products (THMT)  
For Sn/Ag/Cu based solders:  
Maximum Preheat Temperature  
Maximum Pot Temperature  
Maximum Solder Dwell Time  
For Sn/Pb based solders:  
115ºC.  
270ºC.  
7 seconds  
Maximum Preheat Temperature  
Maximum Pot Temperature  
Maximum Solder Dwell Time  
105ºC.  
250ºC.  
6 seconds  
www.murata-ps.com/support  
MDC_UCE.D01 Page 5 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
TYPICAL PERFORMANCE DATA  
UCE-1.5/20-D48 Efficiency vs Line Voltage & Load Current @ 25ºC  
UCE-1.5/20-D48 Maximum Current Temperature Derating  
(Vin = 48V, no baseplate, longitudinal airflow at sea level)  
90  
85  
20  
16  
12  
8
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
Vin = 75V  
80  
Vin = 48V  
Vin = 36V  
75  
4
70  
65  
60  
0
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature (ºC)  
3
6
9
12  
15  
18  
Load Current (A)  
UCE-1.8/30-D48 Efficiency vs Line Voltage & Load Current @ 25ºC  
UCE-1.8/30-D48 Maximum Current Temperature Derating  
(Vin = 48V, no baseplate, longitudinal airflow at sea level)  
95  
90  
85  
80  
75  
70  
65  
60  
55  
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
Vin = 75V  
Vin = 48V  
Vin = 36V  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
0
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
Ambient Temperature (ºC)  
3
5
7
9
11 13 15 17 19 21 23 25 27 29  
Load Current (A)  
UCE-2.5/20-D48 Efficiency vs Line Voltage & Load Current @ 25ºC  
UCE-2.5/20-D48 Maximum Current Temperature Derating  
(Vin = 48V, with baseplate, longitudinal airflow at sea level)  
95  
90  
85  
80  
75  
70  
20  
18  
16  
14  
12  
10  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
Vin = 75V  
Vin = 48V  
Vin = 36V  
1.5 m/s (300 LFM)  
30  
40  
50  
60  
70  
80  
Ambient Temperature (ºC)  
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20  
Load Current (A)  
www.murata-ps.com/support  
MDC_UCE.D01 Page 6 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
TYPICAL PERFORMANCE DATA  
UCE-3.3/15-D48 Efficiency Vs. Line Voltage & Load Current @ +25ºC  
UCE-3.3/15-D48 Maximum Current Temperature Derating  
(Vin = 48V, no baseplate, longitudinal airflow at sea level)  
95  
90  
15  
12  
9
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
Vin = 75V  
Vin = 48V  
Vin = 36V  
85  
80  
75  
70  
6
3
0
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature (ºC)  
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
Load Current (A)  
UCE-3.3/30-D48 Efficiency vs Line Voltage & Load Current @ 25ºC  
95  
90  
85  
80  
75  
70  
65  
60  
55  
50  
45  
40  
22  
20  
18  
16  
14  
12  
10  
8
Vin = 75V  
Vin = 48V  
Vin = 36V  
Power Dissipation  
Vin = 48V  
6
4
2
0
3
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30  
Load Current (A)  
UCE-3.3/30-D48 Maximum Current Temperature Derating  
(Vin=48V, no baseplate, longitudinal airflow at sea level)  
UCE-3.3/30-D48 Maximum Current Temperature Derating  
(Vin=48V, no baseplate, transverse airflow at sea level)  
35  
35  
30  
25  
20  
15  
10  
5
30  
25  
20  
15  
10  
5
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
0
0
30  
40  
50  
60  
70  
80  
30  
40  
50  
60  
70  
80  
Ambient Temperature (ºC)  
Ambient Temperature (ºC)  
www.murata-ps.com/support  
MDC_UCE.D01 Page 7 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
TYPICAL PERFORMANCE DATA  
UCE-5/10-D48 Efficiency Vs. Line Voltage & Load Current @ +25ºC  
UCE-5/10-D48 Maximum Current Temperature Derating at Sea Level  
(Vin = 48V, transverse airflow, no baseplate)  
100  
98  
96  
94  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
3.5  
3
11  
10  
9
2.5  
2
8
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
Vin = 75V  
Vin = 48V  
Vin = 36V  
7
1.5  
1
6
5
Power Dissipation (Vin = 48V)  
4
0.5  
0
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature (ºC)  
1
2
3
4
5
6
7
8
9
10  
Load Current (A)  
UCE-5/20-D48 Efficiency Efficiency and Power Dissipation @ Ta = +25ºC  
UCE-5/20-D48 Maximum Current Temperature Derating at Sea Level  
(Vin = 48V, transverse airflow, no baseplate)  
96  
16  
14  
12  
10  
8
25  
20  
15  
10  
5
94  
92  
90  
88  
86  
84  
82  
80  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
Vin = 75V  
Vin = 48V  
Vin = 36V  
6
4
0
Power Dissipation (Vin = 48V)  
2
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature (ºC)  
0
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20  
Load Current (A)  
Thermal image with hot spot at full load current with 25 °C ambient; air is flowing at  
100 LFM. Air is flowing across the converter from V– to V+ at 48V input. Identifiable  
and recommended maximum value to be verified in application.  
UCE-12/4.2-D48 Efficiency Vs. Line Voltage & Load Current @ +25ºC  
T5 & Q7, max temp = 120 °C / IPC9592 guidelines.  
95  
90  
85  
80  
75  
70  
65  
60  
Vin = 75V  
Vin = 48V  
Vin = 36V  
0.6  
1.2  
1.8  
2.4  
3.0  
3.6  
4.2  
Load Current (A)  
www.murata-ps.com/support  
MDC_UCE.D01 Page 8 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
TYPICAL PERFORMANCE DATA  
UCE-12/4.2-D48 Maximum Current Temperature Derating  
(Vin = 48V, no baseplate, longitudinal airflow at sea level)  
UCE-12/8.3-D48 Efficiency vs Line Voltage & Load Current @ 25ºC  
95  
90  
85  
80  
75  
70  
4.25  
4
Vin = 75V  
Vin = 48V  
Vin = 36V  
1.0 to 2.0 m/s (200 to 400 LFM)  
3.75  
0.5 m/s (100 LFM)  
3.5  
3.25  
3
3
4
5
6
7
8
30  
40  
50  
60  
70  
80  
Load Current (A)  
Ambient Temperature (ºC)  
UCE-12/8.3-D48 Maximum Current Temperature Derating  
(Vin = 48V, no baseplate, longitudinal airflow at sea level)  
UCE-12/8.3-D48 Maximum Current Temperature Derating at sea level  
(Vin = 48V, with baseplate, airflow is from -Vin to +Vin)  
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
0
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature (ºC)  
Ambient Temperature (ºC)  
UCE-12/10-D48 Efficiency and Power Dissipation @ Ta = +25ºC  
UCE-12/10-D48 Maximum Current Temperature Derating at sea level  
(Vin = 48V, no baseplate, airflow direction from Vin to Vout)  
100  
95  
90  
85  
80  
75  
70  
65  
60  
55  
50  
45  
40  
12  
10  
8
28  
24  
20  
16  
12  
8
Vin = 75V  
Vin = 48V  
Vin = 36V  
6
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
4
2
0
Power Dissipation (Vin = 48V)  
4
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
0
Ambient Temperature (ºC)  
3
4
5
6
7
8
9
10  
Load Current (A)  
www.murata-ps.com/support  
MDC_UCE.D01 Page 9 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
MECHANICAL SPECIFICATIONS  
Dimensions are in inches (mm shown for ref. only).  
PIN Shoulder 1-3, 5-7:  
ij0.078 0.003 (1.98 0.076)  
Third Angle Projection  
PIN Shoulder 4,8:  
ij0.100 0.003 (2.54 0.076)  
Open Frame  
Without Baseplate  
2.30 (58.4)  
Tolerances (unless otherwise specified):  
.XX 0.02 (0.5)  
0.37 max  
(9.4)  
.XXX 0.010 (0.25)  
Angles 2ꢀ  
0.18  
(4.6)  
Components are shown for reference only.  
0.015 minimum clearance  
between standoffs and  
highest component  
2.00 (50.8)  
PINS 1-3, 5-7:  
0.040 0.001 (1.016 0.025) dia.  
PINS 4, 8:  
0.062 0.001 (1.575 0.025) dia.  
3
4
0.300  
(7.62)  
0.300  
0.15  
(3.81)  
0.900  
(22.9)  
2
(7.62)  
1
DOSA-Compliant  
INPUT/OUTPUT CONNECTIONS  
Pin 8  
Bottom view  
Pin  
1
2
3
4
Function P32  
+Vin  
On/Off Control  
–Vin  
Standard pin length is shown. Please refer to the Part Number Structure  
for special order pin lengths.  
–Vout  
5
6
–Sense  
Trim  
7
8
+Sense  
+Vout  
www.murata-ps.com/support  
MDC_UCE.D01 Page 10 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
MECHANICAL SPECIFICATIONS  
Dimensions are in inches (mm shown for ref. only).  
With Baseplate  
Third Angle Projection  
Screw length must not  
go through baseplate.  
PIN Shoulder 1-3, 5-7:  
ij0.078 0.003 (1.98 0.076)  
PIN Shoulder 4,8:  
ij0.100 0.003 (2.54 0.076)  
Tolerances (unless otherwise specified):  
.XX 0.02 (0.5)  
.XXX 0.010 (0.25)  
Angles 2ꢀ  
0.50  
(12.7)  
Components are shown for reference only.  
0.18  
(4.6)  
0.015 minimum clearance  
between standoffs and  
highest component  
2.00 (50.8)  
PINS 1-3, 5-7:  
0.040 0.001 (1.016 0.025) dia.  
PINS 4, 8:  
0.062 0.001 (1.575 0.025) dia.  
3
4
0.300  
(7.62)  
0.300  
0.15  
(3.81)  
0.900  
(22.9)  
2
(7.62)  
1
Pin 8  
DOSA-Compliant  
INPUT/OUTPUT CONNECTIONS  
Bottom view  
2.00 (50.8)  
Pin  
1
Function P32  
+Vin  
2
3
4
5
On/Off Control  
–Vin  
–Vout  
–Sense  
Trim  
M3 threaded insert 2  
places, See notes 1&2  
0.600  
(15.24)  
0.900  
(22.9)  
6
7
8
+Sense  
+Vout  
2.30 (58.4)  
1. M3 screw used to bolt unit's baseplate to other surfaces (such as heatsink)  
must not exceed 0.118'' (3mm) depth below the surface of baseplate  
2. Applied torque per screw should not exceed 5.3 In-lb (0.6 Nm)  
Standard pin length is shown. Please refer to the Part Number Struc-  
ture for special order pin lengths.  
www.murata-ps.com/support  
MDC_UCE.D01 Page 11 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
Input Source Impedance  
TECHNICAL NOTES  
These converters will operate to specifications without external components,  
assuming that the source voltage has very low impedance and reasonable  
input voltage regulation. Since real-world voltage sources have finite imped-  
ance, performance is improved by adding external filter components. Some-  
times only a small ceramic capacitor is sufficient. Since it is difficult to totally  
characterize all applications, some experimentation may be needed. Note that  
external input capacitors must accept high speed switching currents.  
Input Fusing  
Certain applications and/or safety agencies may require fuses at the inputs of  
power conversion components. Fuses should also be used when there is the  
possibility of sustained input voltage reversal which is not current-limited. For  
greatest safety, we recommend a fast blow fuse installed in the ungrounded  
input supply line with a value which is approximately twice the maximum line  
current, calculated at the lowest input voltage.  
Because of the switching nature of DC-DC converters, the input of these  
converters must be driven from a source with both low AC impedance and  
adequate DC input regulation. Performance will degrade with increasing input  
inductance. Excessive input inductance may inhibit operation. The DC input  
regulation specifies that the input voltage, once operating, must never degrade  
below the Shut-Down Threshold under all load conditions. Be sure to use  
adequate trace sizes and mount components close to the converter.  
The installer must observe all relevant safety standards and regulations. For  
safety agency approvals, install the converter in compliance with the end-user  
safety standard.  
Input Reverse-Polarity Protection  
If the input voltage polarity is reversed, an internal body diode will become  
forward biased and likely draw excessive current from the power source. If this  
source is not current-limited or the circuit appropriately fused, it could cause  
permanent damage to the converter. Please be sure to install a properly  
rated external input fuse.  
I/O Filtering, Input Ripple Current and Output Noise  
All models in this converter series are tested and specified for input reflected  
ripple current and output noise using designated external input/output compo-  
nents, circuits and layout as shown in the figures below. External input capaci-  
tors (Cin in the figure) serve primarily as energy storage elements, minimizing  
line voltage variations caused by transient IR drops in the input conductors.  
Users should select input capacitors for bulk capacitance (at appropriate  
frequencies), low ESR and high RMS ripple current ratings. In the figure below,  
the Cbus and Lbus components simulate a typical DC voltage bus. Your specific  
system configuration may require additional considerations. Please note that  
the values of Cin, Lbus and Cbus will vary according to the specific converter  
model.  
Input Under-Voltage Shutdown and Start-Up Threshold  
Under normal start-up conditions, converters will not begin to regulate properly  
until the rising input voltage exceeds and remains at the Start-Up Threshold  
Voltage (see Specifications). Once operating, converters will not turn off until  
the input voltage drops below the Under-Voltage Shutdown Limit. Subsequent  
restart will not occur until the input voltage rises again above the Start-Up  
Threshold. This built-in hysteresis prevents any unstable on/off operation at a  
single input voltage.  
Users should be aware however of input sources near the Under-Voltage  
Shutdown whose voltage decays as input current is consumed (such as  
capacitor inputs), the converter shuts off and then restarts as the external  
capacitor recharges. Such situations could oscillate. To prevent this, make  
sure the operating input voltage is well above the UV Shutdown voltage AT ALL  
TIMES.  
TO  
CURRENT  
PROBE  
OSCILLOSCOPE  
+VIN  
−VIN  
L
BUS  
+
+
V
IN  
CBUS  
CIN  
Start-Up Delay  
Assuming that the output current is set at the rated maximum, the Vin to Vout  
Start-Up Time (see Specifications) is the time interval between the point when  
the rising input voltage crosses the Start-Up Threshold and the fully loaded  
regulated output voltage enters and remains within its specified regulation  
band. Actual measured times will vary with input source impedance, external  
input capacitance, input voltage slew rate and final value of the input voltage  
as it appears at the converter.  
C
IN = 33μF, ESR < 700mΩ @ 100kHz  
BUS = 220μF, ESR < 100mΩ @ 100kHz  
C
L
BUS = 12μH  
Figure 2. Measuring Input Ripple Current  
In critical applications, output ripple and noise (also referred to as periodic  
and random deviations or PARD) may be reduced by adding filter elements  
such as multiple external capacitors. Be sure to calculate component tempera-  
ture rise from reflected AC current dissipated inside capacitor ESR.  
These converters include a soft start circuit to moderate the duty cycle of the  
PWM controller at power up, thereby limiting the input inrush current.  
The On/Off Remote Control interval from inception to Vout regulated  
assumes that the converter already has its input voltage stabilized above the  
Start-Up Threshold before the On command. The interval is measured from the  
On command until the output enters and remains within its specified regulation  
band. The specification assumes that the output is fully loaded at maximum  
rated current.  
www.murata-ps.com/support  
MDC_UCE.D01 Page 12 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
Note that the temperatures are of the ambient airflow, not the converter  
itself which is obviously running at higher temperature than the outside air.  
Also note that very low flow rates (below about 25 LFM) are similar to “natural  
convection,” that is, not using fan-forced airflow.  
+SENSE  
+VOUT  
RLOAD  
SCOPE  
C1  
C2  
Murata Power Solutions makes Characterization measurements in a closed  
cycle wind tunnel with calibrated airflow. We use both thermocouples and an  
infrared camera system to observe thermal performance. As a practical matter,  
it is quite difficult to insert an anemometer to precisely measure airflow in  
most applications. Sometimes it is possible to estimate the effective airflow if  
you thoroughly understand the enclosure geometry, entry/exit orifice areas and  
the fan flowrate specifications.  
−VOUT  
−SENSE  
C1 = 1μF  
C2 = 10μF  
LOAD 2-3 INCHES (51-76mm) FROM MODULE  
CAUTION: If you exceed these Derating guidelines, the converter may have  
an unplanned Over Temperature shut down. Also, these graphs are all collected  
near Sea Level altitude. Be sure to reduce the derating for higher altitude.  
Figure 3. Measuring Output Ripple and Noise (PARD)  
Floating Outputs  
Output Overvoltage Protection (OVP)  
Since these are isolated DC-DC converters, their outputs are “floating” with  
respect to their input. The essential feature of such isolation is ideal ZERO  
CURRENT FLOW between input and output. Real-world converters however do  
exhibit tiny leakage currents between input and output (see Specifications).  
These leakages consist of both an AC stray capacitance coupling component  
and a DC leakage resistance. When using the isolation feature, do not allow  
the isolation voltage to exceed specifications. Otherwise the converter may  
be damaged. Designers will normally use the negative output (-Output) as  
the ground return of the load circuit. You can however use the positive output  
(+Output) as the ground return to effectively reverse the output polarity.  
This converter monitors its output voltage for an over-voltage condition. If  
the output exceeds OVP limits, the sensing circuit will power down the unit,  
and the output voltage will decrease. After a time-out period, the PWM will  
automatically attempt to restart, causing the output voltage to ramp up to its  
rated value. It is not necessary to power down and reset the converter for the  
automatic OVP-recovery restart.  
If the fault condition persists and the output voltage climbs to excessive  
levels, the OVP circuitry will initiate another shutdown cycle. This on/off cycling  
is referred to as “hiccup” mode.  
Minimum Output Loading Requirements  
Output Fusing  
All models regulate within specification and are stable under no load to full  
load conditions. Operation under no load might however slightly increase  
output ripple and noise.  
The converter is extensively protected against current, voltage and temperature  
extremes. However your application circuit may need additional protection. In  
the extremely unlikely event of output circuit failure, excessive voltage could be  
applied to your circuit. Consider using appropriate external protection.  
Thermal Shutdown  
To protect against thermal overstress, these converters include thermal  
shutdown circuitry. If environmental conditions cause the temperature of the  
DC-DC’s to rise above the Operating Temperature Range up to the shutdown  
temperature, an on-board electronic temperature sensor will power down  
the unit. When the temperature decreases below the turn-on threshold, the  
converter will automatically restart. There is a small amount of hysteresis to  
prevent rapid on/off cycling. The temperature sensor is typically located adja-  
cent to the switching controller, approximately in the center of the unit. See the  
Performance and Functional Specifications.  
Output Current Limiting  
As soon as the output current increases to approximately 125% to 150% of  
its maximum rated value, the DC-DC converter will enter a current-limiting  
mode. The output voltage will decrease proportionally with increases in output  
current, thereby maintaining a somewhat constant power output. This is also  
commonly referred to as power limiting.  
Current limiting inception is defined as the point at which full power falls  
below the rated tolerance. See the Performance/Functional Specifications.  
Note particularly that the output current may briefly rise above its rated value  
in normal operation as long as the average output power is not exceeded. This  
enhances reliability and continued operation of your application. If the output  
current is too high, the converter will enter the short circuit condition.  
CAUTION: If you operate too close to the thermal limits, the converter may  
shut down suddenly without warning. Be sure to thoroughly test your applica-  
tion to avoid unplanned thermal shutdown.  
Temperature Derating Curves  
Output Short Circuit Condition  
The graphs in this data sheet illustrate typical operation under a variety of  
conditions. The Derating curves show the maximum continuous ambient air  
temperature and decreasing maximum output current which is acceptable  
under increasing forced airflow measured in Linear Feet per Minute (“LFM”).  
Note that these are AVERAGE measurements. The converter will accept brief  
increases in current or reduced airflow as long as the average is not exceeded.  
When a converter is in current-limit mode, the output voltage will drop as the  
output current demand increases. If the output voltage drops too low (approxi-  
mately 98% of nominal output voltage for most models), the magnetically  
coupled voltage used to develop the PWM bias voltage will also drop, thereby  
shutting down the PWM controller. Following a time-out period, the PWM will  
restart, causing the output voltage to begin rising to its appropriate value.  
www.murata-ps.com/support  
MDC_UCE.D01 Page 13 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
If the short-circuit condition persists, another shutdown cycle will initiate.  
This rapid on/off cycling is called “hiccup mode.” The hiccup cycling reduces  
the average output current, thereby preventing excessive internal temperatures  
and/or component damage.  
Contact and PCB resistance  
losses due to IR drops  
+VOUT  
1
+VIN  
IOUT  
+SENSE  
The “hiccup” system differs from older latching short circuit systems  
because you do not have to power down the converter to make it restart. The  
system will automatically restore operation as soon as the short circuit condi-  
tion is removed.  
Sense Current  
ON/OFF  
CONTROL  
2
3
TRIM  
SENSE  
-VOUT  
LOAD  
Sense Return  
IOUT Return  
Remote Sense Input  
Use the Sense inputs with caution. Sense is normally connected at the load.  
Sense inputs compensate for output voltage inaccuracy delivered at the load.  
This is done by correcting IR voltage drops along the output wiring and the  
current carrying capacity of PC board etch. This output drop (the difference  
between Sense and Vout when measured at the converter) should not exceed  
0.5V. Consider using heavier wire if this drop is excessive. Sense inputs also  
improve the stability of the converter and load system by optimizing the control  
loop phase margin.  
VIN  
Contact and PCB resistance  
losses due to IR drops  
Figure 4. Remote Sense Circuit Configuration  
Trimming the Output Voltage  
The Trim input to the converter allows the user to adjust the output voltage  
over the rated trim range (please refer to the Specifications). In the trim equa-  
tions and circuit diagrams that follow, trim adjustments use either a trimpot or  
a single fixed resistor connected between the Trim input and either the +Sense  
or –Sense terminals. (On some converters, an external user-supplied precision  
DC voltage may also be used for trimming). Trimming resistors should have a  
low temperature coefficient ( 100 ppm/deg.C or less) and be mounted close  
to the converter. Keep leads short. If the trim function is not used, leave the  
trim unconnected. With no trim, the converter will exhibit its specified output  
voltage accuracy.  
Note: The Sense input and power Vout lines are internally connected through  
low value resistors to their respective polarities so that the converter can  
operate without external connection to the Sense. Nevertheless, if the Sense  
function is not used for remote regulation, the user should connect +Sense to  
+Vout and –Sense to –Vout at the converter pins.  
The remote Sense lines carry very little current. They are also capacitively  
coupled to the output lines and therefore are in the feedback control loop to  
regulate and stabilize the output. As such, they are not low impedance inputs  
and must be treated with care in PC board layouts. Sense lines on the PCB  
should run adjacent to DC signals, preferably Ground. In cables and discrete  
wiring, use twisted pair, shielded tubing or similar techniques.  
There are two CAUTIONs to observe for the Trim input:  
CAUTION: To avoid unplanned power down cycles, do not exceed EITHER  
the maximum output voltage OR the maximum output power when setting the  
trim. Be particularly careful with a trimpot. If the output voltage is excessive,  
the OVP circuit may inadvertantly shut down the converter. If the maximum  
power is exceeded, the converter may enter current limiting. If the power is  
exceeded for an extended period, the converter may overheat and encounter  
overtemperature shut down.  
Any long, distributed wiring and/or significant inductance introduced into the  
Sense control loop can adversely affect overall system stability. If in doubt, test  
your applications by observing the converter’s output transient response during  
step loads. There should not be any appreciable ringing or oscillation. You  
may also adjust the output trim slightly to compensate for voltage loss in any  
external filter elements. Do not exceed maximum power ratings.  
Please observe Sense inputs tolerance to avoid improper operation:  
CAUTION: Be careful of external electrical noise. The Trim input is a senstive  
input to the converter’s feedback control loop. Excessive electrical noise may  
cause instability or oscillation. Keep external connections short to the Trim  
input. Use shielding if needed.  
[Vout(+) −Vout(-)] − [Sense(+) −Sense(-)] ≤ 10% of Vout  
Output overvoltage protection is monitored at the output voltage pin, not the  
Sense pin. Therefore excessive voltage differences between Vout and Sense  
together with trim adjustment of the output can cause the overvoltage protec-  
tion circuit to activate and shut down the output.  
Power derating of the converter is based on the combination of maximum  
output current and the highest output voltage. Therefore the designer must  
ensure:  
(Vout at pins) x (Iout) (Max. rated output power)  
www.murata-ps.com/support  
MDC_UCE.D01 Page 14 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
Trimming by Using an External Voltage Source  
+VOUT  
1. The easiest way to trim the output using an external voltage source is to  
drive the Trim pin directly from a variable source. The following equation can  
be used to calculate the voltage at the Trim pin.  
+VIN  
External  
+SENSE  
source  
+
Vo  
ON/OFF  
CONTROL  
TRIM  
–SENSE  
–VOUT  
LOAD  
Vtrim = 2 x 1.225 x  
− 1.225  
Vonominal  
Vo is the output voltage you want; Vonominal is the nominal output voltage;  
Vtrim is the voltage that should appear at the trim pin.  
–VIN  
2. If the purpose of trimming is to compensate voltage drop of power path  
from converter to the Load, you may separately connect the sense pin directly  
to the load. It’s much easier than real time adjusting trim voltage.  
Figure 5.Trimming with an external source  
3. CAUTION: To avoid unplanned power down cycles, do not exceed EITHER  
the maximum output voltage OR the maximum output power when setting  
the trim. If the output voltage is excessive, the OVP circuit may shut down the  
converter. If the maximum power is exceeded, the converter may enter current  
limiting. If the power is exceeded for an extended period, the converter may  
overheat and encounter overtemperature shut down. Be careful of external  
electrical noise. The Trim input is a sensitive input to the converter’s feedback  
control loop. Excessive electrical noise may cause instability or oscillation.  
Trim Equations  
Trim Down  
Trim Up  
Connect trim resistor between  
Connect trim resistor between  
trim pin and −Sense  
trim pin and +Sense  
5.11 × VNOM × (1+Δ)  
1.225 × Δ  
− 5.11  
5.11  
Δ
RTrimDn (k Ω) =  
RTrimUp (k Ω) =  
− 10.22  
− 10.22  
Δ
Where,  
Δ = | (VNOM − VOUT) / VNOM |  
VNOM is the nominal, untrimmed output voltage.  
VOUT is the desired new output voltage.  
Do not exceed the specified trim range or maximum power ratings when adjusting trim.  
Use 1% precision resistors mounted close to the converter on short leads.  
www.murata-ps.com/support  
MDC_UCE.D01 Page 15 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
Trim Circuits  
+VOUT  
+SENSE  
TRIM  
+VIN  
+VCC  
ON/OFF  
CONTROL  
ON/OFF  
CONTROL  
LOAD  
–SENSE  
–VOUT  
-VIN  
–VIN  
Figure 6.Trim Connections Using A Trimpot  
Figure 8. Driving the On/Off Control Pin (suggested circuit)  
+VOUT  
+SENSE  
TRIM  
+VOUT  
+SENSE  
TRIM  
+VIN  
+VIN  
RTRIM DOWN  
ON/OFF  
CONTROL  
ON/OFF  
CONTROL  
LOAD  
LOAD  
RTRIM UP  
–SENSE  
–VOUT  
–SENSE  
–VOUT  
–VIN  
–VIN  
Figure 7.Trim Connections To Increase Output Voltages  
Figure 9.Trim Connections To Decrease Output Voltages  
Connect sense to its respective VOUT pin if sense is not used with a remote load.  
Remote On/Off Control  
There are two CAUTIONs for the On/Off Control:  
On the input side, a remote On/Off Control can be specified with either positive  
or negative logic logic.  
CAUTION: While it is possible to control the On/Off with external logic if  
you carefully observe the voltage levels, the preferred circuit is either an open  
drain/open collector transistor, a switch or a relay (which can thereupon be  
controlled by logic) returned to negative Vin.  
Positive: Models equipped with positive logic are enabled when the On/Off  
pin is left open or is pulled high to +Vin with respect to –Vin. An internal bias  
current causes the open pin to rise to approximately +15V. Some models will  
also turn on at lower intermediate voltages (see Specifications). Positive-logic  
devices are disabled when the On/Off is grounded or brought to within a low  
voltage (see Specifications) with respect to –Vin.  
CAUTION: Do not apply voltages to the On/Off pin when there is no input  
power voltage. Otherwise the converter may be permanently damaged.  
Output Capacitive Load  
These converters do not require external capacitance added to achieve rated  
specifications. Users should only consider adding capacitance to reduce switch-  
ing noise and/or to handle spike current step loads. Install only enough capaci-  
tance to achieve noise objectives. Excess external capacitance may cause  
regulation problems, slower transient response and possible instability. Proper  
wiring of the Sense inputs will improve these factors under capacitive load.  
Negative: Models with negative logic are on (enabled) when the On/Off is  
grounded or brought to within a low voltage (see Specifications) with respect to  
–Vin. The device is off (disabled) when the On/Off is left open or is pulled high  
to approximately +15V with respect to –Vin.  
Dynamic control of the On/Off function should be able to sink the speci-  
fied signal current when brought low and withstand appropriate voltage  
when brought high. Be aware too that there is a finite time in milliseconds  
(see Specifications) between the time of On/Off Control activation and stable,  
regulated output. This time will vary slightly with output load type and current  
and input conditions.  
The maximum rated output capacitance and ESR specification is given for a  
capacitor installed immediately adjacent to the converter. Any extended output  
wiring or smaller wire gauge or less ground plane may tolerate somewhat higher  
capacitance. Also, capacitors with higher ESR may use a larger capacitance.  
www.murata-ps.com/support  
MDC_UCE.D01 Page 16 of 17  
UCE Series  
Isolated, High-Density, Eighth-Brick  
Low Profile DC-DC Converters  
Vertical Wind Tunnel  
Murata Power Solutions employs a computer controlled  
custom-designed closed loop vertical wind tunnel, infrared  
video camera system, and test instrumentation for accurate  
airflow and heat dissipation analysis of power products.  
The system includes a precision low flow-rate anemometer,  
variable speed fan, power supply input and load controls,  
temperature gauges, and adjustable heating element.  
IR Transparent  
optical window  
Variable  
speed fan  
Unit under  
test (UUT)  
The IR camera monitors the thermal performance of the  
Unit Under Test (UUT) under static steady-state conditions. A  
special optical port is used which is transparent to infrared  
wavelengths.  
IR Video  
Camera  
Both through-hole and surface mount converters are  
soldered down to a 10"x 10" host carrier board for realistic  
heat absorption and spreading. Both longitudinal and trans-  
verse airflow studies are possible by rotation of this carrier  
board since there are often significant differences in the heat  
dissipation in the two airflow directions. The combination of  
adjustable airflow, adjustable ambient heat, and adjustable  
Input/Output currents and voltages mean that a very wide  
range of measurement conditions can be studied.  
Heating  
element  
Precision  
low-rate  
anemometer  
3” below UUT  
The collimator reduces the amount of turbulence adjacent  
to the UUT by minimizing airflow turbulence. Such turbu-  
lence influences the effective heat transfer characteristics  
and gives false readings. Excess turbulence removes more  
heat from some surfaces and less heat from others, possibly  
causing uneven overheating.  
Ambient  
temperature  
sensor  
Airflow  
collimator  
Both sides of the UUT are studied since there are different  
thermal gradients on each side. The adjustable heating element  
and fan, built-in temperature gauges, and no-contact IR camera mean  
that power supplies are tested in real-world conditions.  
Figure 10. Vertical Wind Tunnel  
This product is subject to the following operating requirements  
and the Life and Safety Critical Application Sales Policy:  
Refer to: http://www.murata-ps.com/requirements/  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
ISO 9001 and 14001 REGISTERED  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
notice.  
© 2014 Murata Power Solutions, Inc.  
www.murata-ps.com/support  
MDC_UCE.D01 Page 17 of 17  

相关型号:

UCE-3.3/30-D48P-C

DC-DC Regulated Power Supply Module, 1 Output, 99W, Hybrid, PACKAGE-8

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UCE-3.3/30-D48PB-C

DC-DC Regulated Power Supply Module, 1 Output, 99W, Hybrid, PACKAGE-8

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UCE-3.3/30-D48PHL1-C

DC-DC Regulated Power Supply Module, 1 Output, 99W, Hybrid, PACKAGE-8

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UCE-5/10-D48N-C

Isolated, High-Density, Eighth-Brick 100W DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UCE-5/10-D48PBHL1-C

DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, PACKAGE-8

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UCE-5/10-D48PBL1-C

DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, PACKAGE-8

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UCE-5/20-D48N-C

Isolated, High-Density, Eighth-Brick 100W DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UCE-5/20-D48NB-C

DC-DC Regulated Power Supply Module, ROHS COMPLIANT, EIGHTH-BRICK PACKAGE-8

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UCE-5/20-D48NBHL2-C

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, PACKAGE-8

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UCE-5/20-D48PHL2-C

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, PACKAGE-8

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UCE-5/20-D48PL2-C

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, PACKAGE-8

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MURATA

UCE4017019CH005005-10.00M

Clipped Sine Output Oscillator, 10MHz Nom, LCC, 4 PIN

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
PLETRONICS