UCQ-1.2/40-D24PBH-C [MURATA]

DC-DC Regulated Power Supply Module, 1 Output, 48W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-8;
UCQ-1.2/40-D24PBH-C
型号: UCQ-1.2/40-D24PBH-C
厂家: muRata    muRata
描述:

DC-DC Regulated Power Supply Module, 1 Output, 48W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-8

文件: 总24页 (文件大小:549K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Single Output UCQ Models  
s
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Typical units  
FEATURES  
PRODUCT OVERVIEW  
„ꢀ  
For applications requiring improved electrical and  
thermal performance at reduced cost, consider  
DATEL’s new UCQ series “quarter brick” DC/DC  
power converters. These compact units measure  
just 1.45" x 2.3" x 0.4" (36.8 x 60.9 x 10.2 mm)  
and fit the industry-standard footprint.  
The UCQ’s feature full isolation to 2250Vdc  
meeting BASIC insulation requirements of  
Standard quarter-brick package/pinout  
„ꢀ  
Low cost; Low profile, 0.4" (10.2mm)  
UL/EN/IEC 60950-1. Input filters reduce propa-  
gated switching noise back to input sources. Also  
included is a remote On/Off switch control (with  
positive or negative polarity), output trim adjustable  
over nominal and output sense functions to reduce  
„ꢀ  
24V or 48V nominal input  
„ꢀ  
Outputs: 1.2V to 15V  
„ꢀ  
Interleaved synchronous-rectifier topology  
• Ultra high efficiency  
• No output reverse conduction  
Available outputs range between 1.2V @ 30 Amps  
to 15V @ 6.7 Amps and accept a wide input range. power lead losses. Extensive protection items  
The UCQ’s interleaved, synchronous-rectifier  
topology offers high efficiency (up to 93%), tight  
line and load regulation, low noise and fast step  
response. A single-board optimized open-frame  
design contributes to impressive thermal opera-  
tion. UCQ’s will operate up to +70°C and 100 LFM  
airflow with no derating.  
avoid damage from out of limit voltages, currents  
and temperatures. Protection faults automatically  
recover using the hiccup technique. Besides safety  
testing to 60950-1, certifications for the UCQ in-  
clude application for EMC compliance (to EN55022/  
CISPR22 with filter), qualification testing.  
„ꢀ  
Outstanding thermal performance  
„ꢀ  
On/off control, trim & sense functions  
„ꢀ  
Fully isolated, 2250Vdc (BASIC)  
Output overvoltage protection  
„
„ꢀ  
Fully I/O protected; Thermal shutdown  
„ꢀ  
Designed to meet UL/EN/IEC60950-1  
safety approvals  
+SENSE  
(7)  
+VOUT  
(8)  
+VIN  
(3)  
SWITCH  
CONTROL  
–VOUT  
(4)  
–VIN  
(1)  
–SENSE  
(5)  
PWM  
CONTROLLER  
OPTO  
ISOLATION  
REFERENCE &  
ERROR AMP  
VOUT  
TRIM  
(6)  
INPUT UNDERVOLTAGE, INPUT  
OVERVOLTAGE, AND OUTPUT  
OVERVOLTAGE COMPARATORS  
* Can be ordered with positive (standard) or negative (optional) polarity.  
REMOTE  
ON/OFF  
CONTROL*  
(2)  
Figure 1. Simplified Schematic  
For full details go to  
www.murata-ps.com/rohs  
Typical topology may vary between units.  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 1 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE ➀  
Output  
Input  
R/N (mVp-p)  
Regulation (Max.) ➁  
Line Load  
IIN full  
load  
Efficiency  
VOUT  
IOUT  
Power  
VIN Nom.  
(Volts)  
Range  
IIN no  
(Volts) (Amps) (Watts) Typ.  
Max.  
(Volts) load (mA) (Amps)  
Min.  
Typ.  
Root Models ➀  
UCQ-1.2/40-D24P-C  
UCQ-1.2/30-D48N-C  
UCQ-1.5/25-D48N-C  
UCQ-1.5/40-D48N-C  
UCQ-1.8/30-D48N-C  
UCQ-1.8/40-D48N-C  
UCQ-2.5/40-D24P-C  
UCQ-2.5/30-D48N-C  
UCQ-3.3/35-D24P-C  
UCQ-3.3/20-D48N-C  
UCQ-3.3/30-D48N-C  
UCQ-3.3/40-D48N-C  
UCQ-5/20-D24P-C  
UCQ-5/20-D48N-C  
UCQ-5/25-D48N-C  
UCQ-12/8.3-D48N-C  
UCQ-15/6.7-D48N-C  
1.2  
1.2  
1.5  
1.5  
1.8  
1.8  
2.5  
2.5  
3.3  
3.3  
3.3  
3.3  
5
40  
30  
25  
40  
30  
40  
40  
30  
35  
20  
30  
40  
20  
20  
25  
8.3  
48  
36  
Please contact Murata Power Solutions for further information.  
50  
50  
50  
80  
50  
80  
50  
80  
50  
50  
60  
50  
35  
50  
100  
100  
80  
0.125%  
0.125%  
0.125%  
0.125%  
0.1%  
0.25%  
0.25%  
0.25%  
0.25%  
0.2%  
48  
48  
48  
48  
48  
24  
48  
24  
48  
48  
48  
24  
48  
48  
48  
48  
36-75  
36-75  
36-75  
36-75  
36-75  
18-36  
36-75  
18-36  
36-75  
36-75  
36-75  
18-36  
36-75  
36-75  
36-75  
36-75  
30  
50  
0.90  
0.94  
1.45  
1.31  
1.70  
4.96  
1.80  
5.41  
1.53  
2.3  
81%  
81%  
85%  
83%  
86%  
82%  
85%  
87%  
88.5%  
89.5%  
89%  
88%  
89%  
88%  
90%  
90%  
83%  
83%  
86%  
86%  
88%  
84%  
87%  
89%  
90%  
91%  
90%  
91.5%  
92%  
90%  
91%  
92%  
37.5  
60  
100  
100  
100  
120  
100  
120  
80  
50  
54  
45  
72  
30  
100  
75  
0.125%  
0.125%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.2%  
120  
50  
115.5  
66  
130  
50  
0.125%  
0.125%  
0.1%  
99  
80  
50  
132  
100  
100  
125  
99.6  
100  
60  
30  
3.06  
4.55  
2.26  
2.89  
2.28  
2.28  
0.125%  
0.125%  
0.125%  
0.125%  
0.125%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
160  
80  
5
55  
5
100  
150  
150  
30  
12  
15  
80  
100  
6.7 100.5 100  
Please refer to the part number structure for additional ordering part numbers and options.  
All specifications are at nominal line voltage and full load, +25 deg.C unless otherwise noted. See detailed specifications. Output capacitors are 1 μF ceramic || 10 μF electrolytic. I/O caps are necessary for  
our test equipment and may not be needed for your application.  
Outline dimensions: 2.3 × 1.45 × 0.40 inches  
58.4 × 36.8 × 10.2 mm  
Pinout: P32 (all models)  
PART NUMBER STRUCTURE  
U CQ - 3.3 / 30 D48 N B H Lx - C  
-
Output  
Configuration:  
Unipolar,  
single output  
RoHS Hazardous Materials compliance  
C = RoHS-6, standard (does not claim EU RoHS exemption 7B–lead in solder)  
Y = RoHS-5 (with lead), optional, special order  
Pin length option  
Blank = standard pin length 0.180 in. (4.6 mm)  
L1 = 0.110 in. (2.79 mm)*  
Quarter-Brick Package  
Nominal Output Voltage  
L2 = 0.145 in. (3.68 mm)*  
*Special quantity order is required;  
no sample quantities available.  
Maximum Rated Output :  
Current in Amps  
Conformal coating (optional)  
Blank = no coating, standard  
H = coating added, optional special order  
Input Voltage Range:  
D24 = 18-36 Volts (24V nominal)  
D48 = 36-75 Volts (48V nominal)  
Note:  
Baseplate (optional)  
Some model number combinations  
may not be available. Please contact  
Murata Power Solutions.  
Blank = No baseplate, standard  
B = Baseplate installed, optional special order  
On/Off Control Polarity  
P = Positive polarity (standard for D24, optional for D48)  
N = Negative polarity (standard for D48, optional for D24)  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 2 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
FUNCTIONAL SPECIFICATIONS  
UCQ-1.2/30-D48 UCQ-1.5/25-D48 UCQ-1.5/40-D48 UCQ-1.8/30-D48 UCQ-1.8/40-D48  
Input  
Input voltage range  
Start-up threshold, Volts  
See ordering guide.  
34  
34  
33  
34  
32  
34  
34  
32  
Undervoltage  
shutdown, V  
32.5  
none  
32.5  
Overvoltage shutdown  
Reflected (back) ripple  
current, mA pk-pk  
10-30, model dependent  
Input Current  
Full load conditions  
Inrush transient, A2sec  
Output short circuit, mA  
See ordering guide.  
0.05  
50-200, model dependent  
Low line (VIN = min.),  
Amps  
1.23  
1.26  
L-C  
1.96  
1.74  
2.30  
Standby mode, mA  
(Off, UV, OT shutdown)  
1-10, model dependent  
Pi-type  
Internal input filter type  
Pi-type  
Pi-type  
Pi-type  
Reverse polarity  
protection  
None, install external fuse.  
Remote On/Off Control  
Positive logic  
OFF = Ground pin to +0.8V  
(P model suffix)  
ON = Open or +3.5 to +13.5V max  
Negative logic  
(N model suffix)  
OFF = Open or +3.5 to +13.5V  
ON = Ground pin to +0.8V max  
Current, mA  
1
Output  
Voltage output range  
Voltage output accuracy  
See ordering guide.  
1% of VNOM., (50% load)  
Adjustment range,  
% of VNOM.  
10%  
−20 + 10  
10%  
10%  
10%  
Temperature coefficient  
Minimum loading  
0.02% of VOUT range per °C  
No minimum loading.  
Remote sense  
compensation  
+10%  
Ripple/noise  
(20 MHz bandwidth)  
See ordering guide.  
Line/Load regulation  
Efficiency  
See ordering guide.  
See ordering guide.  
Maximum capacitive  
loading, μF low ESR  
<0.02Ω max.,  
1,000  
10,000  
10,000  
4,700  
10,000  
resistive load  
Specs are typical unless noted.  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 3 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
FUNCTIONAL SPECIFICATIONS  
UCQ-2.5/40-D24 UCQ-2.5/30-D48 UCQ-3.3/35-D24 UCQ-3.3/20-D48 UCQ-3.3/30-D48  
Input  
Input voltage range  
Start-up threshold, Volts  
See ordering guide.  
17  
16.8  
15  
34  
32  
35  
35  
34  
Undervoltage  
shutdown, V  
15  
none  
34  
Overvoltage shutdown  
Reflected (back) ripple  
current, mA pk-pk  
10-30, model dependent  
Input Current  
Full load conditions  
Inrush transient, A2sec  
Output short circuit, mA  
See ordering guide.  
0.05  
50-200, model dependent  
Low line (VIN = min.),  
Amps  
6.69  
Pi  
2.39  
L-C  
7.21  
2.04  
Pi  
3.02  
Pi  
Standby mode, mA  
(Off, UV, OT shutdown)  
1-10, model dependent  
L-C  
Internal input filter type  
Reverse polarity  
protection  
None, install external fuse.  
Remote On/Off Control  
Positive logic  
OFF = Ground pin to +0.8V  
(P model suffix)  
ON = Open or +3.5 to +13.5V max  
Negative logic  
(N model suffix)  
OFF = Open or +3.5 to +13.5V  
ON = Ground pin to +0.8V max  
Current, mA  
1
Output  
Voltage output range  
Voltage output accuracy  
See ordering guide.  
1% of VNOM., (50% load)  
Adjustment range,  
% of VNOM.  
−20 + 10  
−20 + 10  
10%  
−10 to + 10%  
Temperature coefficient  
Minimum loading  
0.02% of VOUT range per °C  
No minimum loading.  
Remote sense  
compensation  
+10%  
Ripple/noise  
(20 MHz bandwidth)  
See ordering guide.  
Line/Load regulation  
Efficiency  
See ordering guide.  
See ordering guide.  
Maximum capacitive  
loading, μF low ESR  
<0.02Ω max.,  
10,000  
10,000  
10,000  
10,000  
10,000  
resistive load  
Specs are typical unless noted.  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 4 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
FUNCTIONAL SPECIFICATIONS  
UCQ-3.3/40-D48 UCQ-5/20-D24  
UCQ-5/20-D48  
UCQ-5/25-D48 UCQ-12/8.3-D48  
UCQ-15/6.7-D48N-C  
Input  
Input voltage range  
Start-up threshold, Volts  
See ordering guide  
33  
17  
16  
35  
34  
35  
34  
35  
34  
34  
Undervoltage  
shutdown, V  
31.5  
31.5  
Overvoltage shutdown  
none  
Reflected (back) ripple  
current, mA pk-pk  
10-30, model dependent.  
60 max.  
Input Current  
Full load conditions  
Inrush transient, A2sec  
Output short circuit, mA  
See ordering guide.  
0.05  
0.1  
0.03  
120  
1200  
50-200, model dependent  
Low line (VIN = min.),  
Amps  
4.12  
6.04  
L-C  
3.02  
3.82  
3.04  
L-C  
3.03  
Standby mode, mA  
(Off, UV, OT shutdown)  
1-10, model dependent  
L-C  
Internal input filter type  
Pi  
L-C  
Pi  
Reverse polarity  
protection  
None, install external fuse.  
Remote On/Off Control  
Positive logic  
(P model suffix)  
OFF = Ground pin to +0.8V  
ON = Open or +3.5 to +13.5V max  
OFF = Ground pin or to +1V.  
ON = Open or +2.5 to +13.5V  
Negative logic  
(N model suffix)  
OFF = Open or +3.5 to +13.5V  
ON = Ground pin to +0.8V max  
OFF = Open or +2.5 to +13.5V  
ON = Ground pin or to +1V.  
Current, mA  
1
Output  
Voltage output range  
Voltage output accuracy  
See ordering guide.  
1% of VNOM., (50% load)  
Adjustment range,  
% of VNOM.  
−10 to + 10%  
Temperature coefficient  
Minimum loading  
0.02% of VOUT range per °C.  
No minimum loading.  
Remote sense  
compensation  
+10%  
Ripple/noise  
(20 MHz bandwidth)  
See ordering guide.  
Line/Load regulation  
Efficiency  
See ordering guide.  
See ordering guide.  
Maximum capacitive  
loading, μF low ESR  
<0.02Ω max.,  
10,000  
10,000  
10,000  
10,000  
1,000  
1000  
resistive load  
Specs are typical unless noted.  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 5 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
FUNCTIONAL SPECIFICATIONS  
UCQ-1.2/30-D48 UCQ-1.5/25-D48 UCQ-1.5/40-D48 UCQ-1.8/30-D48 UCQ-1.8/40-D48  
Isolation Voltage  
Input to Output,  
Volts min.  
2250  
1500  
1500  
Input to baseplate,  
Volts min.  
Baseplate to output,  
Volts min.  
Isolation resistance, MΩ  
Isolation capacitance, pF  
Isolation safety rating  
Miscellaneous  
10-100, model dependent  
1000  
Basic insulation  
Current limit inception  
(98% of VOUT, after  
warmup), Amps  
35  
35  
49  
35  
49  
Short circuit protection  
method  
Current limiting, hiccup autorestart. Remove overload for recovery.  
Short circuit current,  
Amps  
5
Short circuit duration  
Continuous, output shorted to ground. No damage.  
Overvoltage protection,  
Volts (via magnetic  
feedback)  
1.8  
1.8  
1.95  
2.7 V max  
2.2  
Dynamic characteristics  
Dynamic load response 200 μSec to 1% 200 μSec to 1% 50 μSec to 1% of 100 μSec to 1% 50 μSec to 1% of  
(50-75-50% load step) of final value  
of final value  
final value  
of final value  
final value  
Start-up time  
VIN to VOUT regulated,  
mSec  
10 max.  
Remote On/Off to VOUT  
regulated, mSec  
10 max.  
Switching frequency, KHz  
350 20  
2M hours  
440 40  
400 40  
400  
380 40  
Environmental  
Calculated MTBF  
2.1M hours  
2.2M hours  
2M hours  
2.1M hours  
Operating temperature  
range, °C  
−40 to +85, with derating  
See Derating curves.  
Operating case  
temperature, °C  
(no derating)  
−40 to +120, model dependent  
−55 to +125  
Storage temperature  
range, °C  
Thermal protection/  
shutdown, °C  
110-125, model dependent  
Relative humidity  
To +85°C/85%, non-condensing  
Specs are typical unless noted.  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 6 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
FUNCTIONAL SPECIFICATIONS  
UCQ-2.5/40-D24 UCQ-2.5/30-D48 UCQ-3.3/35-D24 UCQ-3.3/20-D48 UCQ-3.3/30-D48  
Isolation Voltage  
Input to Output,  
Volts min.  
2250  
1500  
1500  
Input to baseplate,  
Volts min.  
Baseplate to output,  
Volts min.  
Isolation resistance, MΩ  
Isolation capacitance, pF  
Isolation safety rating  
Miscellaneous  
10-100, model dependent  
1000  
Basic insulation  
Current limit inception  
(98% of VOUT, after  
warmup), Amps  
46  
37  
41  
24  
35  
Short circuit protection  
method  
Current limiting, hiccup autorestart. Remove overload for recovery.  
Short circuit current,  
Amps  
5
12  
5
Short circuit duration  
Continuous, output shorted to ground. No damage.  
Overvoltage protection,  
Volts (via magnetic  
feedback)  
2.95  
2.95  
4
4.6  
4
Dynamic characteristics  
Dynamic load response 200 μSec to 1% 200 μSec to 1% 200 μSec to 1% 200 μSec to 1.5% 200 μSec to 1%  
(50-75-50% load step) of final value  
of final value  
of final value  
of final value  
of final value  
Start-up time  
VIN to VOUT regulated,  
mSec  
10 max.  
Remote On/Off to VOUT  
regulated, mSec  
10 max.  
Switching frequency, KHz  
480  
480 30  
350 10  
330 40  
330 40  
Environmental  
Calculated MTBF  
2.1M hours  
2.2M hours  
1.7M hours  
1.8M hours  
1.7M hours  
Operating temperature  
range, °C  
−40 to +85, with derating  
See Derating curves.  
Operating case  
temperature, °C  
(no derating)  
−40 to +120, model dependent  
−55 to +125  
Storage temperature  
range, °C  
Thermal protection/  
shutdown, °C  
110-125, model dependent  
Relative humidity  
To +85°C/85%, non-condensing  
Specs are typical unless noted.  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 7 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
FUNCTIONAL SPECIFICATIONS  
UCQ-3.3/40-D48 UCQ-5/20-D24  
UCQ-5/20-D48  
UCQ-5/25-D48 UCQ-12/8.3-D48  
UCQ-15/6.7-D48N-C  
Isolation Voltage  
Input to Output,  
Volts min.  
2250  
1500  
1500  
Input to baseplate,  
Volts min.  
Baseplate to output,  
Volts min.  
Isolation resistance, MΩ  
Isolation capacitance, pF  
Isolation safety rating  
Miscellaneous  
10-100, model dependent  
1000  
Basic insulation  
Current limit inception  
(98% of VOUT, after  
warmup), Amps  
49  
26  
22  
27  
10  
9
Short circuit protection  
method  
Current limiting, hiccup autorestart. Remove overload for recovery.  
Short circuit current,  
Amps  
15  
5
5
5
TBD  
2
Short circuit duration  
Continuous, output shorted to ground. No damage.  
Overvoltage protection,  
Volts (via magnetic  
feedback)  
4.25  
6.25  
TBD  
6.2  
14.4  
18  
Dynamic characteristics  
Dynamic load response 50 μSec to 1% of 200 μSec to 1% 200 μSec to 1% 200 μSec to 1% 200 μSec to 1%  
150 μSec to 2% of final value  
(50-75-50% load step)  
final value  
of final value  
of final value  
of final value  
of final value  
Start-up time  
VIN to VOUT regulated,  
mSec  
5
4
10 max.  
10 max.  
10 max.  
10 max.  
Remote On/Off to VOUT  
regulated, mSec  
5
4
10 max.  
10 max.  
10 max.  
10 max.  
Switching frequency, KHz  
360 20  
400 24  
315 30  
315 30  
330 40  
300 30 KHz  
Environmental  
Calculated MTBF  
2.2M hours  
2.2M hours  
TBD  
1.7M hours  
1.8M hours  
TBD  
Operating temperature  
range, °C.  
−40 to +85, with derating  
See Derating curves.  
Operating case  
temperature, °C  
(no derating)  
−40 to +120, model dependent  
−40 to +110  
Storage temperature  
range, °C  
−55 to +125  
Thermal protection/  
shutdown, °C  
110-125, model dependent  
Relative humidity  
To +85°C/85%, non-condensing  
Specs are typical unless noted.  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 8 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
FUNCTIONAL SPECIFICATIONS  
UCQ-1.2/30-D48 UCQ-1.5/25-D48 UCQ-1.5/40-D48 UCQ-1.8/30-D48 UCQ-1.8/40-D48  
Physical  
Outline dimensions  
Pin material  
Pin diameter  
Pin finish  
See mechanical specs.  
Copper alloy  
0.040/0.062 inches (1.016/1.575 mm)  
Nickel underplate with gold overplate  
Weight, ounces  
Weight, grams  
0.9  
25  
1.06  
30  
0.9  
25  
0.9  
25  
1.23  
35  
Electromagnetic  
interference  
Designed to meet EN55022/CISPR22 (External filter required)  
Safety  
Designed to meet UL 60950-1, CSA C22.2 No.60950-1, IEC/EN 60950-1  
UCQ-2.5/40-D24 UCQ-2.5/30-D48 UCQ-3.3/35-D24 UCQ-3.3/20-D48 UCQ-3.3/30-D48  
Physical  
Outline dimensions  
Pin material  
Pin diameter  
Pin finish  
See mechanical specs.  
Copper alloy  
0.040/0.062 inches (1.016/1.575 mm)  
Nickel underplate with gold overplate  
Weight, ounces  
Weight, grams  
1.06  
30  
1.06  
30  
1.06  
30  
0.7  
20  
1.06  
30  
Electromagnetic  
interference  
Designed to meet EN55022/CISPR22 (External filter required)  
Safety  
Designed to meet UL 60950-1, CSA C22.2 No.60950-1, IEC/EN 60950-1  
UCQ-3.3/40-D48 UCQ-5/20-D24  
UCQ-5/20-D48  
UCQ-5/25-D48 UCQ-12/8.3-D48  
UCQ-15/6.7-D48N-C  
Physical  
Outline dimensions  
Pin material  
Pin diameter  
Pin finish  
See mechanical specs.  
Copper alloy  
0.040/0.062 inches (1.016/1.575 mm)  
Nickel underplate with gold overplate  
Weight, ounces  
Weight, grams  
1.25  
35.5  
1.06  
30  
1.06  
30  
1.06  
30  
1.13  
32  
1.034  
29.3  
Electromagnetic  
interference  
Designed to meet EN55022/CISPR22 (External filter required)  
Designed to meet UL 60950-1, CSA C22.2 No.60950-1, IEC/EN 60950-1  
Safety  
Specs are typical unless noted.  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 9 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Specification Notes  
(1) All models are tested and specified with external 1||10 μF ceramic/tantalum output capacitors no external input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate  
our test equipment and may not be required to achieve specified performance in your applications. All models are stable and regulate within spec under no-load conditions. All specifications are typical unless  
noted. General conditions for Specifications are +25 deg.C, VIN and VOUT = nominal, full load. Adequate airflow must be supplied for extended testing under power.  
(2) Input Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is CIN = 33 μF, 100V tantalum, CBUS = 220 μF, 100V electrolytic, LBUS = 12 μH.  
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if the  
total RMS current over time does not exceed the Derating curve. All Derating curves are presented at sea level altitude. Be aware of reduced power dissipation with increasing altitude.  
(4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fixed conditions, Tpcboard = +25 deg.C, full output load, natural air convection.  
(5) The On/Off Control is normally controlled by a switch or open collector or open drain transistor. But it may also be driven with external logic or by applying appropriate external voltages which are referenced to  
Input Common.  
(6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting.  
(7) The outputs are not intended to sink appreciable reverse current.  
(8) Output noise may be further reduced by adding an external filter. See I/O Filtering and Noise Reduction.  
(9) All models are fully operational and meet published specifications, including “cold start” at –40 C.  
(10) Regulation specifications describe the deviation as the line input voltage or output load current is varied from a nominal midpoint value to either extreme.  
(11) Output accuracy is dependent on user-supplied trim resistors. To achieve high accuracy, use 1% or better tolerance metal-film resistors mounted close to the converter.  
(12) Output current limit and short circuit protection is non-latching. When the overcurrent fault is removed, the converter will immediately recover.  
(13) Do not exceed maximum power specifications when adjusting the output trim.  
(14) At zero output current, the output may contain low frequency components which exceed the ripple specification. The output may be operated indefinitely with no load.  
(15) Input Fusing: To ensure reverse input protection with full output load, always connect an external input fast-blow fuse in series with the +VIN input. Use approximately twice the full input current rating with  
nominal input voltage.  
(16) “Hiccup” overcurrent operation repeatedly attempts to restart the converter with a brief, full-current output. If the overcurrent condition still exists, the restart current will be removed and then tried again. This  
short current pulse prevents overheating and damaging the converter. Once the fault is removed, the converter immediately recovers normal operation.  
(17) Normally, the Sense lines are connected at the remote load to compensate for IR voltage drops in the power wiring and to improve dynamic response. If Sense is not used, each Sense pin should be con-  
nected at the converter to its respective Vout pin.  
Product Adaptations  
Murata Power Solutions offers several variations of our core product family.  
These products are available under scheduled quantity orders and may also  
include separate manufacturing documentation from a mutually agreeable  
Product Specification. Since these product adaptations largely share a common  
parts list and similar specifications and test methods with their root products,  
they are provided at excellent costs and delivery. Please contact Murata Power  
Solutions for details.  
These models are all negative On/Off polarity, no baseplate, conformal coat-  
ing added, 3.68mm pin length, and RoHS-5 hazardous substance compliance  
(with lead).  
UCQ-3.3/30-D48NBHL2-Y  
UCQ-3.3/40-D48NBHL2-Y  
These models are all negative On/Off polarity, baseplate installed, conformal  
coating added, 3.68mm pin length, and RoHS-5 hazardous substance compli-  
ance (with lead).  
As of this date, the following products are available:  
UCQ-1.2/30-D48NHL2-Y  
UCQ-1.8/30-D48NHL2-Y  
Absolute Maximum Ratings  
UCQ-1.8/40-D48NHL2-Y  
Input Voltage  
Continuous  
Transient (100msec)  
24V Models  
0 to +36 Volts  
+50 Volts  
48V Models  
0 to +75 Volts  
+100 Volts  
UCQ-2.5/30-D48NHL2-Y  
UCQ-2.5/40-D48NHL2-Y  
On/Off Control  
Input Reverse Polarity Protection  
Output Current  
0V min. to +13.5V max.  
See Fuse section  
Current-limited. Devices can withstand  
sustained short circuit without damage.  
–40 to +100°C (with derating)  
–55 to +125°C  
UCQ-5/20-D48NHL2-Y  
UCQ-12/8.3-D48NHL2-Y  
Operating Temperature  
Storage Temperature  
These are stress ratings. Exposure of devices to greater than any of these conditions may  
adversely affect long-term reliability. Proper operation under conditions other than those  
listed in the Performance/Functional Specifications Table is not implied, nor recommended.  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 10 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
TYPICAL PERFORMANCE CURVES  
UCQ-1.2/30-D48 Maximum Current Temperature Derating  
No baseplate, VIN = 48V (at sea level), longitudinal airflow  
UCQ-1.2/30-D48 Efficiency vs Line Voltage and Load Current @25˚ C  
95  
35  
30  
25  
90  
85  
80  
75  
70  
20  
V
IN = 36V  
400 LFM  
65  
60  
55  
50  
45  
40  
300 LFM  
V
IN = 48V  
15  
200 LFM  
V
IN = 75V  
100 LFM  
10  
5
0
3
6
9
12  
15  
18  
21  
24  
27  
75  
30  
30  
35  
40  
45  
50  
55  
60  
65  
70  
70  
70  
75  
75  
75  
80  
80  
80  
Load Current (Amps)  
Ambient Temperature ( C)  
°
UCQ-1.5/25-D48 Efficiency vs Line Voltage and Load Current @25˚ C  
UCQ-1.5/25-D48 Maximum Current Temperature Derating  
No baseplate, VIN = 48V (at sea level), longitudinal airflow  
90  
88  
86  
84  
82  
80  
78  
30  
25  
20  
15  
10  
VIN = 75V  
76  
74  
72  
70  
68  
66  
64  
62  
60  
V
IN = 48V  
V
IN = 36V  
400 LFM  
300 LFM  
200 LFM  
5
100 LFM  
0
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25  
30  
35  
40  
45  
50  
55  
60  
65  
Load Current (Amps)  
Ambient Temperature ( C)  
°
UCQ-1.8/30-D48 Efficiency vs Line Voltage and Load Current @25˚ C  
UCQ-1.8/30-D48 Maximum Current Temperature Derating  
No baseplate, VIN = 48V (at sea level), longitudinal airflow  
90  
32  
30  
28  
26  
24  
88  
86  
84  
V
IN = 36V  
IN = 48V  
IN = 75V  
82  
80  
78  
76  
74  
72  
70  
V
V
22  
400 LFM  
300 LFM  
200 LFM  
20  
100 LFM  
Natural convection  
18  
4
6
8
10  
12  
14  
16  
18  
20  
22  
24  
26  
28  
30  
30  
35  
40  
45  
50  
55  
60  
65  
Load Current (Amps)  
Ambient Temperature ( C)  
°
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 11 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
TYPICAL PERFORMANCE CURVES  
UCQ-1.8/40-D48 Maximum Current Temperature Derating at Sea Level  
(VIN = 48V, no baseplate, airflow is from Vin to Vout)  
UCQ-1.8/40-D48 Efficiency and Power Dissipation @25˚ C  
95  
22  
20  
18  
16  
14  
12  
10  
8
45  
40  
35  
30  
90  
85  
V
IN = 75V  
80  
75  
70  
65  
60  
55  
50  
45  
40  
V
IN = 48V  
400 LFM  
V
IN = 36V  
25  
300 LFM  
200 LFM  
20  
15  
10  
5
100 LFM  
Natural Convection  
6
4
Power Dissipation  
IN = 48V  
2
V
0
0
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
4
8
12  
16  
20  
24  
28  
32  
36  
40  
Ambient Temperature ( C)  
°
Load Current (Amps)  
UCQ-2.5/30-D48 Efficiency vs Line Voltage and Load Current @25˚ C  
UCQ-2.5/30-D48 Maximum Current Temperature Derating  
No baseplate, VIN = 24V (at sea level)  
95  
35  
30  
25  
20  
15  
90  
85  
80  
75  
V
IN = 75V  
70  
65  
60  
55  
50  
45  
40  
V
IN = 48V  
V
IN = 36V  
400 LFM  
10  
300 LFM  
200 LFM  
5
100 LFM  
0
1
3
6
9
12  
15  
18  
21  
24  
27  
30  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
Load Current (Amps)  
Ambient Temperature ( C)  
°
UCQ-2.5/40-D24 Efficiency vs Line Voltage and Load Current @25˚ C  
UCQ-2.5/40-D24 Maximum Current Temperature Derating  
No baseplate, VIN = 24V (at sea level)  
95  
35  
30  
25  
20  
15  
90  
85  
V
IN = 24V  
80  
75  
70  
65  
60  
55  
50  
V
IN = 18V  
V
IN = 35V  
10  
400 LFM  
300 LFM  
5
200 LFM  
100 LFM  
0
3
6
9
12  
15  
18  
21  
24  
27  
30  
33  
36  
39 40  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
Load Current (Amps)  
Ambient Temperature ( C)  
°
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 12 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
TYPICAL PERFORMANCE CURVES  
UCQ-3.3/20-D48 Maximum Current Temperature Derating at Sea Level  
(VIN = 48V, longitudinal airflow, no baseplate)  
UCQ-3.3/20-D48 Efficiency vs Line Voltage and Load Current @25°C  
95  
18  
15  
12  
9
20  
90  
85  
18  
100 LFM  
200 LFM  
16  
14  
12  
10  
VIN = 36V  
80  
75  
70  
65  
VIN = 48V  
300 LFM  
6
V
IN = 75V  
400 LFM  
3
Power Dissipation  
IN = 48V  
V
0
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
2
5
8
11  
14  
17  
20  
Ambient Temperature (°C)  
Load Current (Amps)  
UCQ-3.3/30-D48 Maximum Current Temperature Derating at Sea Level  
(VIN = 48V, no baseplate, airflow is from Vin to Vout)  
UCQ-3.3/30-D48 Efficiency vs Line Voltage and Load Current @25°C  
95  
15  
12  
9
30  
28  
26  
90  
85  
VIN = 36V  
24  
100 LFM  
VIN = 48V  
22  
200 LFM  
80  
75  
70  
6
VIN = 75V  
20  
300 LFM  
400 LFM  
Power Dissipation  
3
18  
VIN = 48V  
16  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
0
Ambient Temperature (°C)  
3
6
9
12  
15  
18  
21  
24  
27  
30  
Load Current (Amps)  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 13 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
TYPICAL PERFORMANCE CURVES  
UCQ-3.3/35-D24 Efficiency vs Line Voltage and Load Current @25˚ C  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
VIN = 36V  
VIN = 24V  
VIN = 18V  
3
5
7
9
11  
15  
17  
19  
21  
23  
25  
27  
29  
31  
33  
35  
Load Current (Amps)  
UCQ-3.3/35-D24 Maximum Current Temperature Derating at Sea Level  
UCQ-3.3/35-D24 Maximum Current Temperature Derating at Sea Level  
(VIN = 24V, with baseplate, airflow is from -Vin to +Vin)  
(VIN = 24V, no baseplate, airflow is from -Vin to +Vin)  
40  
35  
30  
25  
20  
40  
35  
30  
25  
20  
400 LFM  
400 LFM  
300 LFM  
15  
10  
5
15  
10  
5
200 LFM  
300 LFM  
200 LFM  
100 LFM  
100 LFM  
Natural Convection  
Natural Convection  
0
0
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 14 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
TYPICAL PERFORMANCE CURVES  
UCQ-3.3/40-D48 Efficiency and Power Dissipation @25˚ C  
95  
90  
85  
80  
75  
70  
65  
60  
55  
50  
45  
22  
20  
18  
16  
14  
12  
10  
8
VIN = 75V  
V
IN = 48V  
V
IN = 36V  
6
4
Power Dissipation  
IN = 48V  
2
V
40  
4
0
8
12  
16  
20  
24  
28  
32  
36  
40  
Load Current (Amps)  
UCQ-3.3/40-D48 Maximum Current Temperature Derating at Sea Level  
UCQ-3.3/40-D48 Maximum Current Temperature Derating at Sea Level  
(VIN = 48V, with baseplate, transverse airflow)  
(VIN = 48V, no baseplate, transverse airflow)  
50  
50  
40  
30  
40  
30  
400 LFM  
20  
20  
300 LFM  
400 LFM  
300 LFM  
200 LFM  
200 LFM  
100 LFM  
10  
10  
Natural Convection  
100 LFM  
Natural Convection  
0
0
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ( C)  
Ambient Temperature ( C)  
°
°
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 15 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
TYPICAL PERFORMANCE CURVES  
UCQ-5/20-D24 Efficiency and Power Dissipation @25°C  
96  
92  
88  
84  
80  
76  
72  
68  
64  
60  
14  
12  
10  
8
V
IN = 18V  
VIN = 24V  
6
V
IN = 36V  
4
Power Dissipation  
IN = 24V  
V
2
0
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20  
Load Current (Amps)  
UCQ-5/20-D24 Maximum Current Temperature Derating at Sea Level  
UCQ-5/20-D24 Maximum Current Temperature Derating at Sea Level  
(VIN = 24V, no baseplate, airflow is from -Vin to +Vin)  
(VIN = 24V, with baseplate, airflow is from -Vin to +Vin)  
22  
20  
18  
16  
25  
20  
14  
100 LFM  
100 LFM  
15  
12  
200 LFM  
200 LFM  
10  
10  
8
6
4
2
0
300 LFM  
300 LFM  
400 LFM  
400 LFM  
5
0
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
UCQ-5/20-D48 Maximum Current Temperature Derating at Sea Level  
(VIN = 48V, no baseplate, airflow is from -Vin to +Vin)  
UCQ-5/20-D48  
Efficiency vs Line Voltage and Load Current @25°C  
22  
20  
18  
16  
95  
90  
85  
100 LFM  
14  
200 LFM  
12  
300 LFM  
10  
VIN = 36V  
400 LFM  
8
80  
75  
70  
VIN = 50V  
6
4
2
0
V
IN = 75V  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature (°C)  
4
6
8
10  
12  
14  
16  
18  
20  
Load Current (Amps)  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 16 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
TYPICAL PERFORMANCE CURVES  
UCQ-5/25-D48 Maximum Current Temperature Derating at Sea Level  
(VIN = 48V, no baseplate, airflow is from Vin to Vout)  
UCQ-5/25-D48 Efficiency and Power Dissipation @25˚ C  
95  
18  
16  
14  
12  
10  
8
30  
25  
20  
90  
85  
VIN = 75V  
V
IN = 48V  
80  
75  
70  
65  
60  
55  
50  
V
IN = 36V  
15  
400 LFM  
300 LFM  
6
10  
200 LFM  
100 LFM  
4
5
0
Power Dissipation  
2
VIN = 48V  
0
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
3
5
7
9
11  
13  
15  
17  
19  
21  
23  
25  
Ambient Temperature ( C)  
Load Current (Amps)  
°
UCQ-12/8.3-D48 Maximum Current Temperature Derating at Sea Level  
(VIN = 48V, no baseplate, airflow is from Vin to Vout)  
UCQ-12/8.3-D48 Efficiency and Power Dissipation @25˚ C  
100  
20  
9
8
7
6
5
95  
90  
85  
18  
16  
14  
12  
10  
8
V
IN = 75V  
80  
75  
70  
65  
60  
55  
50  
V
IN = 48V  
400 LFM  
4
3
2
1
0
V
IN = 36V  
300 LFM  
200 LFM  
6
100 LFM  
4
Power Dissipation  
IN = 48V  
V
2
0
8.3  
0.8  
1.6  
2.4  
3.2  
4
4.8  
5.6  
6.4  
7.2  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ( C)  
°
Load Current (Amps)  
UCQ-12/8.3-D48 Maximum Current Temperature Derating at Sea Level  
(VIN = 48V, with baseplate, longitudinal airflow)  
10  
9
8
100 LFM  
200 LFM  
7
300 LFM  
400 LFM  
6
5
4
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ( C)  
°
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 17 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
TYPICAL PERFORMANCE CURVES  
UCQ-15/6.7-D48 Maximum Current Temperature Derating at Sea Level  
(VIN = 48V, no baseplate, airflow is from Vin to Vout)  
UCQ-15/6.7-D48 Efficiency and Power Dissipation @Ta = 25˚ C  
100  
15  
14  
13  
12  
11  
10  
9
95  
90  
85  
6.5  
100 LFM  
200 LFM  
300 LFM  
V
IN = 75V  
80  
75  
70  
65  
60  
55  
50  
400 LFM  
5.5  
4.5  
3.5  
VIN = 48V  
8
7
VIN = 36V  
6
5
4
Power Dissipation  
3
V
IN = 48V  
2
1
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
1.2  
1.7 2.2  
2.7  
3.2  
3.7 4.2  
4.7  
5.2  
5.7 6.2  
6.7  
Ambient Temperature ( C)  
°
Load Current (Amps)  
UCQ-15/6.7-D48 Maximum Current Temperature Derating at Sea Level  
(VIN = 48V, with baseplate, airflow is from Vin to Vout)  
6.5  
100 LFM  
5.5  
4.5  
3.5  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ( C)  
°
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 18 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
TYPICAL PERFORMANCE CURVES  
5#1ꢀꢁꢂꢁꢃꢁꢄꢀ$ꢅꢆ /UTPUT 4RANSIENT 2ESPONSE  
ꢀ6). ꢁ ꢂꢃ6RESISTIVE LOAD STEP ꢅꢆꢇ TO ꢆꢈꢇꢉ  
5#1ꢀꢁꢂꢁꢃꢁꢄꢀ$ꢅꢆ /UTPUT 4RANSIENT 2ESPONSE  
ꢀ6). ꢁ ꢂꢃ6RESISTIVE LOAD STEP ꢆꢈꢇ TO ꢅꢆꢇꢉ  
ꢊꢈꢈ§SECꢋDIV  
ꢊꢈꢈ§SECꢋDIV  
5#1ꢀꢁꢂꢁꢃꢁꢄꢀ$ꢅꢆ %NABLE /Nꢃ/FF  
ꢀ6). ꢁ ꢂꢃ6)/54 ꢁ ꢌꢈ!ꢉ  
5#1ꢀꢁꢂꢁꢃꢁꢄꢀ$ꢅꢆ 2IPPLE AND .OISE  
ꢀ6). ꢁ ꢂꢃ6)/54 ꢁ ꢌꢈ! RESISTIVEꢄ OUTPUT CAPS ꢊ§& CERAMIC \\ ꢊꢈ§& TANTALUMꢉ  
6/54  
ꢊ6ꢋDIV  
#ONTROL  
0IN  
ꢍ6ꢋDIV  
ꢍMSECꢋDIV  
ꢍ§SECꢋDIV  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 19 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
MECHANICAL SPECIFICATIONS  
UCQ with Optional Baseplate  
0.40  
(10.2)  
2.30 (58.4)  
A
2.30 (58.4)  
A
1.860 (47.2)  
A
PINS 1-3, 5-7:  
0.040Ø 0.002 (1.016 0.05)  
PINS 4, 8:  
0.015 minimum  
clearance between  
standoffs and  
#M3 THD. X 0.15 DEEP  
TYPICAL 4 PL.  
0.18  
(4.6)  
0.062Ø 0.002 (1.575 0.05)  
highest component  
SCREW LENGTH MUST  
NOT GO THROUGH BASEPLATE  
2.00 (50.8)  
A
4
1
2
3
0.50  
(12.7)  
5
6
7
8
0.600  
(15.2)  
Case C67  
0.300  
(7.6)  
BOTTOM VIEW  
PINS 1-3, 5-7:  
0.040Ø 0.002 (1.016 0.05)  
PINS 4, 8:  
0.600 (15.24)  
4 EQ. SP.  
0.18  
(4.6)  
0.062Ø 0.002 (1.575 0.05)  
Dimensions are in inches (mm shown for ref. only).  
Component locations may vary between units.  
Third Angle Projection  
DOSA-Compatible I/O Connections  
Pin  
1
Function P32  
−Input*  
Pin  
5
Function P32  
−Sense  
Standard pin length is shown. Please refer to the Part  
Number Structure for special order pin lengths.  
2
Remote On/Off  
+Input*  
6
Output Trim  
+Sense  
3
7
Tolerances (unless otherwise specified):  
.XX 0.02 (0.5)  
4
−Output  
8
+Output  
*
These converters are pin-for-pin/plug-compatible to competitive  
units. Other units may use different pin numbering or alternate  
outline views. When laying out your PC board, follow the pin  
.XXX 0.010 (0.25)  
Angles 2ꢀ  
Components are shown for reference only.  
FUNCTION. DOSA designates Pin 1 as +Input and Pin 3 as -Input.  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 20 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
TECHNICAL NOTES  
Input Fusing  
I/O Filtering, Input Ripple Current, and Output Noise  
Certain applications and/or safety agencies may require the installation of  
fuses at the inputs of power conversion components. Fuses should also be  
used if the possibility of sustained, non-current-limited, input-voltage polarity  
reversals exists. For DATEL UCQ series DC/DC converters, we recommend the  
use of a fast blow fuse, installed in the ungrounded input supply line with a  
typical value about twice the maximum input current, calculated at low line  
with the converter’s minimum efficiency.  
All models in the UCQ Series are tested/specified for input reflected ripple  
current and output noise using the specified external input/output components/  
circuits and layout as shown in the following two figures. External input capaci-  
tors (CIN in Figure 2) serve primarily as energy-storage elements, minimiz-  
ing line voltage variations caused by transient IR drops in conductors from  
backplane to the DC/DC. Input caps should be selected for bulk capacitance  
(at appropriate frequencies), low ESR, and high rms-ripple-current ratings. The  
switching nature of DC/DC converters requires that dc voltage sources have  
low ac impedance as highly inductive source impedance can affect system sta-  
bility. In Figure 2, CBUS and LBUS simulate a typical dc voltage bus. Your specific  
system configuration may necessitate additional considerations.  
All relevant national and international safety standards and regulations must  
be observed by the installer. For system safety agency approvals, the convert-  
ers must be installed in compliance with the requirements of the end- use  
safety standard, i.e. IEC/EN/UL60950-1.  
TO  
Input Reverse-Polarity Protection  
CURRENT  
PROBE  
OSCILLOSCOPE  
If the input voltage polarity is accidentally reversed, an internal diode will  
become forward biased and likely draw excessive current from the power  
source. If this source is not current limited or the circuit appropriately fused, it  
could cause permanent damage to the converter.  
3
1
+INPUT  
–INPUT  
LBUS  
+
V
IN  
CBUS  
CIN  
Input Under-Voltage Shutdown and Start-Up Threshold  
Under normal start-up conditions, devices will not begin to regulate properly  
until the ramping-up input voltage exceeds the Start-Up Threshold Voltage.  
Once operating, devices will not turn off until the input voltage drops below the  
Under-Voltage Shutdown limit. Subsequent re-start will not occur until the input  
is brought back up to the Start-Up Threshold. This built in hysteresis prevents  
any unstable on/off situations from occurring at a single input voltage.  
C
IN = 33μF, ESR < 700m: @ 100kHz  
BUS = 220μF, ESR < 100mW @ 100kHz  
C
L
BUS = 12μH  
Figure 2. Measuring Input Ripple Current  
In critical applications, output ripple/noise (also referred to as periodic and  
random deviations or PARD) may be reduced below specified limits using filter-  
ing techniques, the simplest of which is the installation of additional external  
output capacitors. They function as true filter elements and should be selected  
for bulk capacitance, low ESR and appropriate frequency response.  
Start-Up Time  
The VIN to VOUT Start-Up Time is the time interval between the point at which  
the ramping input voltage crosses the Start-Up Threshold and the fully loaded  
output voltage enters and remains within its specified accuracy band. Actual  
measured times will vary with input source impedance, external input capaci-  
tance, and the slew rate and final value of the input voltage as it appears at the  
converter. The UCQ Series implements a soft start circuit to limit the duty cycle  
of its PWM controller at power up, thereby limiting the input inrush current.  
All external capacitors should have appropriate voltage ratings and be  
located as close to the converter as possible. Temperature variations for all  
relevant parameters should also be taken carefully into consideration. The most  
effective combination of external I/O capacitors will be a function of line voltage  
and source impedance, as well as particular load and layout conditions.  
The On/Off Control to VOUT start-up time assumes the converter has its  
nominal input voltage applied but is turned off via the On/Off Control pin. The  
specification defines the interval between the point at which the converter is  
turned on (released) and the fully loaded output voltage enters and remains  
within its specified accuracy band. Similar to the VIN to VOUT start-up, the On/Off  
Control to VOUT start-up time is also governed by the internal soft start circuitry  
and external load capacitance. The difference in start up time from VIN to VOUT  
and from On/Off Control to VOUT is therefore insignificant.  
In Figure 3, the two copper strips simulate real-world PCB impedances  
between the power supply and its load. In order to minimize measurement  
errors, scope measurements should be made using BNC connectors, or the  
probe ground should be less than ½ inch and soldered directly to the fixture.  
Floating Outputs  
Since these are isolated DC/DC converters, their outputs are “floating” with  
respect to their input. Designers will normally use the –Output (pin 4) as the  
ground/return of the load circuit. You can however, use the +Output (pin 8) as  
ground/return to effectively reverse the output polarity.  
Input Source Impedance  
The input of UCQ converters must be driven from a low ac-impedance source.  
The DC/DC’s performance and stability can be compromised by the use of  
highly inductive source impedances. The input circuit shown in Figure 2 is a  
practical solution that can be used to minimize the effects of inductance in the  
input traces. For optimum performance, components should be mounted close  
to the DC/DC converter.  
Minimum Output Loading Requirements  
UCQ converters employ a synchronous-rectifier design topology and all models  
regulate within spec and are stable under no-load to full load conditions.  
Operation under no-load conditions however might slightly increase the output  
ripple and noise.  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 21 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Remote Sense  
7
8
COPPER STRIP  
Note: The Sense and VOUT lines are internally connected through low-value  
resistors. Nevertheless, if the sense function is not used for remote regulation  
the user should connect the +Sense to +VOUT and –Sense to –VOUT at the DC/  
DC converter pins. UCQ series converters employ a sense feature to provide  
point of use regulation, thereby overcoming moderate IR drops in PCB conduc-  
tors or cabling. The remote sense lines carry very little current and therefore  
require minimal cross-sectional-area conductors. The sense lines, which are  
capacitively coupled to their respective output lines, are used by the feedback  
control-loop to regulate the output. As such, they are not low impedance points  
and must be treated with care in layouts and cabling. Sense lines on a PCB  
should be run adjacent to dc signals, preferably ground.  
+SENSE  
+OUTPUT  
RLOAD  
SCOPE  
C1  
C2  
4
5
–OUTPUT  
–SENSE  
COPPER STRIP  
C1 = 1μF CERAMIC  
C2 = 10μF TANTALUM  
LOAD 2-3 INCHES (51-76mm) FROM MODULE  
[VOUT(+)-VOUT(–)] – [Sense(+)-Sense(–)] d 10%VOUT  
Figure 3. Measuring Output Ripple/Noise (PARD)  
In cables and discrete wiring applications, twisted pair or other techniques  
should be used. Output over-voltage protection is monitored at the output volt-  
age pin, not the Sense pin. Therefore, excessive voltage differences between  
VOUT and Sense in conjunction with trim adjustment of the output voltage can  
cause the over-voltage protection circuitry to activate (see Performance Speci-  
fications for over-voltage limits). Power derating is based on maximum output  
current and voltage at the converter’s output pins. Use of trim and sense func-  
tions can cause output voltages to increase, thereby increasing output power  
beyond the converter’s specified rating, or cause output voltages to climb into  
the output over-voltage region. Therefore, the designer must ensure:  
Thermal Shutdown  
The UCQ converters are equipped with thermal-shutdown circuitry. If environ-  
mental conditions cause the temperature of the DC/DC converter to rise above  
the designed operating temperature, a precision temperature sensor will power  
down the unit. When the internal temperature decreases below the threshold  
of the temperature sensor, the unit will self start. See Performance/Functional  
Specifications.  
Output Over-Voltage Protection  
The UCQ output voltage is monitored for an over-voltage condition using a com-  
parator. The signal is optically coupled to the primary side and if the output volt-  
age rises to a level which could be damaging to the load, the sensing circuitry  
will power down the PWM controller causing the output voltage to decrease.  
Following a time-out period the PWM will restart, causing the output voltage  
to ramp to its appropriate value. If the fault condition persists, and the output  
voltage again climbs to excessive levels, the over-voltage circuitry will initiate  
another shutdown cycle. This on/off cycling is referred to as “hiccup” mode.  
(VOUT at pins) x (IOUT) d rated output power  
#ONTACT AND 0#" RESISTANCE  
LOSSES DUE TO )2 DROPS  
ꢎ/54054  
n).054  
)/54  
ꢎ3%.3%  
Current Limiting  
3ENSE #URRENT  
As soon as the output current increases to approximately 130% of its rated  
value, the DC/DC converter will go into a current-limiting mode. In this condi-  
tion, the output voltage will decrease proportionately with increases in output  
current, thereby maintaining somewhat constant power dissipation. This is  
commonly referred to as power limiting. Current limit inception is defined  
as the point at which the full-power output voltage falls below the specified  
tolerance. See Performance/Functional Specifications. If the load current, being  
drawn from the converter, is significant enough, the unit will go into a short  
circuit condition as described below.  
/.ꢋ/&&  
#/.42/,  
42)-  
n3%.3%  
,/!$  
3ENSE 2ETURN  
)/54 2ETURN  
ꢎ).054  
n/54054  
#ONTACT AND 0#" RESISTANCE  
LOSSES DUE TO )2 DROPS  
Figure 4. Remote Sense Circuit Configuration  
Short Circuit Condition  
When a converter is in current-limit mode, the output voltage will drop as the  
output current demand increases. If the output voltage drops too low, the mag-  
netically coupled voltage used to develop primary side voltages will also drop,  
thereby shutting down the PWM controller. Following a time-out period, the  
PWM will restart causing the output voltage to begin ramping to their appropri-  
ate value. If the short-circuit condition persists, another shutdown cycle will be  
initiated. This on/off cycling is referred to as “hiccup” mode. The hiccup cycling  
reduces the average output current, thereby preventing internal temperatures  
from rising to excessive levels. The UCQ Series is capable of enduring an  
indefinite short circuit output condition.  
Trimming Output Voltage  
UCQ converters have a trim capability (pin 6) that enables users to adjust the  
output voltage (refer to the trim equations and trim graphs that follow). Adjust-  
ments to the output voltage can be accomplished via a trim pot (Figure 5) or  
a single fixed resistor as shown in Figures 6 and 7. A single fixed resistor can  
increase or decrease the output voltage depending on its connection. Resistors  
should be located close to the converter and have TCR’s less than 100ppm/°C  
to minimize sensitivity to changes in temperature. If the trim function is not  
used, leave the trim pin open.  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 22 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
A single resistor connected from the Trim pin (pin 6) to the +Sense (pin 7)  
will increase the output voltage. A resistor connected from the Trim Pin (pin 6)  
to the –Sense (pin 5) will decrease the output voltage.  
ꢎ/54054  
n).054  
ꢎ3%.3%  
42)-  
Trim adjustments greater than the specified range can have an adverse  
affect on the converter’s performance and are not recommended. Excessive  
voltage differences between VOUT and Sense, in conjunction with trim adjust-  
ment of the output voltage, can cause the over-voltage protection circuitry to  
activate (see Performance Specifications for over-voltage limits). Temperature/  
power derating is based on maximum output current and voltage at the  
converter’s output pins. Use of the trim and sense functions can cause output  
voltages to increase, thereby increasing output power beyond the converter’s  
specified rating, or cause output voltages to climb into the output over-voltage  
region. Therefore:  
/.ꢋ/&&  
#/.42/,  
,/!$  
242)- $/7.  
n3%.3%  
n/54054  
ꢎ).054  
Figure 7.Trim Connections To Decrease Output Voltages Using Fixed Resistors  
(VOUT at pins) x (IOUT) t rated output power  
The Trim pin (pin 6) is a relatively high impedance node that can be suscep-  
tible to noise pickup when connected to long conductors in noisy environments.  
ꢎ/54054  
n).054  
ꢎ3%.3%  
Trim Equations  
(For all models except the UCQ-1.2/40-D24 and -1.2/30-D48)  
ꢆꢐꢍꢍ  
452.3  
/.ꢋ/&&  
#/.42/,  
42)-  
n3%.3%  
,/!$  
Trim Down  
Trim Up  
Connect trim resistor between  
Connect trim resistor between  
trim pin and −Sense  
trim pin and +Sense  
ꢎ).054  
5.11 × VNOM × (1+')  
1.225 × '  
5.11  
'
− 5.11  
n/54054  
R
TrimDn (k Ω) =  
RTrimUp (k Ω) =  
− 10.22  
− 10.22  
'
Figure 5.Trim Connections Using A Trimpot  
Where,  
' = | (VNOM − VOUT) / VNOM |  
VNOM is the nominal, untrimmed output voltage.  
VOUT is the desired new output voltage.  
ꢎ/54054  
n).054  
ꢎ3%.3%  
42)-  
Do not exceed the specified trim range or maximum power ratings  
when adjusting trim. Use 1% precision resistors mounted close  
to the converter on short leads.  
/.ꢋ/&&  
#/.42/,  
,/!$  
242)- 50  
(For the UCQ-1.2/40-D24 and -1.2/30-D48)  
n3%.3%  
n/54054  
Trim Down  
Trim Up  
Connect trim resistor between  
Connect trim resistor between  
ꢎ).054  
trim pin and −Sense  
trim pin and +Sense  
5.11 × VNOM × (1+')  
5.11  
2' − 2  
Figure 6.Trim Connections To Increase Output Voltages Using Fixed Resistors  
R
TrimDn (k Ω) =  
RTrimUp (k Ω) =  
1.225 × '  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 23 of 24  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
On/Off Control  
Dynamic control of the remote on/off function is best accomplished with a  
mechanical relay or an open-collector/open-drain drive circuit (optically isolated  
if appropriate). The drive circuit should be able to sink appropriate current (see  
Performance Specifications) when activated and withstand appropriate voltage  
when deactivated. Applying an external voltage to pin 2 when no input power is  
applied to the converter can cause permanent damage to the converter.  
The input-side, remote On/Off Control function (pin 2) can be ordered to operate  
with either polarity:  
Positive (no suffix) polarity models are enabled when pin 2 is left open (or  
is pulled high, applying +3.5V to +13.5V with respect to –Input, pin 1) as per  
Figure 8. Positive-polarity devices are disabled when pin 2 is pulled low (0 to  
0.8V with respect to –Input).  
Negative (“N” suffix) polarity devices are off when pin 2 is left open (or  
pulled high, applying +3.5V to +13.5V), and on when pin 2 is pulled low (0 to  
1V) with respect to –Input as shown in Figure 9.  
+INPUT  
3
+INPUT  
3
2
+VCC  
+Vcc  
13V CIRCUIT  
2
ON/OFF  
CONTROL  
ON/OFF  
CONTROL  
5V CIRCUIT  
1
–INPUT  
1
–INPUT  
Figure 8. Driving the Negative Polarity On/Off Control Pin  
(simplified circuit)  
Figure 9. Driving the Negative Polarity On/Off Control Pin  
(simplified circuit)  
Soldering Guidelines  
Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceeding these specifica-  
tions may cause damage to the product. Your production environment may differ; therefore please thoroughly review these guidelines with your process engineers.  
Wave Solder Operations for through-hole mounted products (THMT)  
For Sn/Ag/Cu based solders:  
For Sn/Pb based solders:  
Maximum Preheat Temperature 115° C.  
Maximum Preheat Temperature 105° C.  
Maximum Pot Temperature  
Maximum Solder Dwell Time  
270° C.  
Maximum Pot Temperature  
250° C.  
7 seconds Maximum Solder Dwell Time  
6 seconds  
This product is subject to the following operating requirements  
and the Life and Safety Critical Application Sales Policy:  
Refer to: http://www.murata-ps.com/requirements/  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
ISO 9001 and 14001 REGISTERED  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
notice.  
© 2012 Murata Power Solutions, Inc.  
www.murata-ps.com/support  
MDC_UCQ Models.B20 Page 24 of 24  

相关型号:

UCQ-1.2/40-D24PBHL1-C

DC-DC Regulated Power Supply Module, 1 Output, 48W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-8
MURATA

UCQ-1.2/40-D24PBHL2-Y

DC-DC Regulated Power Supply Module, 1 Output, 48W, Hybrid, QUARTER BRICK PACKAGE-8
MURATA

UCQ-1.2/40-D24PH-C

DC-DC Regulated Power Supply Module, 1 Output, 48W, Hybrid, ROHS COMPLIANT, QUARTER-BRICK PACKAGE-8
MURATA

UCQ-1.2/40-D24PL2-Y

DC-DC Regulated Power Supply Module, 1 Output, 48W, Hybrid, QUARTER-BRICK PACKAGE-8
MURATA

UCQ-1.5/25-D48N-C

Low-Profile, Quarter Brick, 8.3-40 Amp Isolated DC/DC Converters
MURATA

UCQ-1.5/25-D48NB-C

DC-DC Regulated Power Supply Module, 1 Output, 37.5W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-8
MURATA

UCQ-1.5/25-D48NBH-C

DC-DC Regulated Power Supply Module, 1 Output, 37.5W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-8
MURATA

UCQ-1.5/25-D48NBHL2-C

DC-DC Regulated Power Supply Module, 1 Output, 37.5W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-8
MURATA

UCQ-1.5/25-D48NH-Y

DC-DC Regulated Power Supply Module, 1 Output, 37.5W, Hybrid, QUARTER-BRICK PACKAGE-8
MURATA

UCQ-1.5/25-D48NL1-C

DC-DC Regulated Power Supply Module, 1 Output, 37.5W, Hybrid, ROHS COMPLIANT, QUARTER-BRICK PACKAGE-8
MURATA

UCQ-1.5/25-D48NL2-C

DC-DC Regulated Power Supply Module, 1 Output, 37.5W, Hybrid, ROHS COMPLIANT, QUARTER-BRICK PACKAGE-8
MURATA

UCQ-1.5/40-D48N-C

Low-Profile, Quarter Brick, 8.3-40 Amp Isolated DC/DC Converters
MURATA