Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Typical units  
FEATURES  
PRODUCT OVERVIEW  
nꢀ  
For applications requiring improved electrical and  
thermal performance at reduced cost, consider  
DATEL’s new UCQ series “quarter brick” DC/DC  
power converters. These compact units measure  
just 1.45" x 2.3" x 0.4" (36.8 x 60.9 x 10.2 mm)  
and fit the industry-standard footprint.  
The UCQ’s feature full isolation to 2250Vdc  
meeting BASIC insulation requirements of  
Standard quarter-brick package/pinout  
nꢀ  
Low cost; Low profile, 0.4" (10.2mm)  
UL/EN/IEC 60950-1. Input filters reduce propa-  
gated switching noise back to input sources. Also  
included is a remote On/Off switch control (with  
positive or negative polarity), output trim adjustable  
over nominal and output sense functions to reduce  
nꢀ  
24V or 48V nominal input  
nꢀ  
Outputs: 1.2V to 12V  
nꢀ  
Interleaved synchronous-rectifier topology  
• Ultra high efficiency  
• No output reverse conduction  
Available outputs range between 1.2V @ 30 Amps  
to 12V @ 8.3 Amps and accept a wide input range. power lead losses. Extensive protection items  
The UCQ’s interleaved, synchronous-rectifier  
topology offers high efficiency (up to 93%), tight  
line and load regulation, low noise and fast step  
response. A single-board optimized open-frame  
design contributes to impressive thermal opera-  
tion. UCQ’s will operate up to +70°C and 100 LFM  
airflow with no derating.  
avoid damage from out of limit voltages, currents  
and temperatures. Protection faults automatically  
recover using the hiccup technique. Besides safety  
testing to 60950-1, certifications for the UCQ  
include application for EMC compliance (to FCC  
class B), qualification testing (including HALT) and  
CE marking.  
nꢀ  
Outstanding thermal performance  
nꢀ  
On/off control, trim & sense functions  
nꢀ  
Fully isolated, 2250Vdc (BASIC)  
Output overvoltage protection  
n
nꢀ  
Fully I/O protected; Thermal shutdown  
nꢀ  
Designed to meet UL/EN/IEC60950-1  
safety approvals  
+SENSE  
(7)  
nꢀ  
Qual/HALT/EMI tested  
+VOUT  
(8)  
+VIN  
(3)  
SWITCH  
CONTROL  
–VOUT  
(4)  
–VIN  
(1)  
–SENSE  
(5)  
PWM  
OPTO  
REFERENCE &  
CONTROLLER  
ISOLATION  
ERROR AMP  
VOUT  
TRIM  
(6)  
INPUT UNDERVOLTAGE, INPUT  
OVERVOLTAGE, AND OUTPUT  
OVERVOLTAGE COMPARATORS  
* Can be ordered with positive (standard) or negative (optional) polarity.  
REMOTE  
ON/OFF  
CONTROL*  
(2)  
Typical topology may vary between units.  
Figure 1. Simplified Schematic  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 1 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Performance Specifications and Ordering Guide ➀  
ORDERING GUIDE  
Output  
Input  
R/N (mVp-p)  
Regulation (Max.) ➁  
Line Load  
Iin full  
load  
Efficiency  
Vo u t  
Io u t  
Power  
Vin Nom.  
(Volts)  
Range  
Iin no  
(Volts) (Amps) (Watts) Typ.  
Max.  
(Volts) load (mA) (Amps)  
Min.  
Typ.  
Root Models ➀  
UCQ-1.2/40-D24P-C  
UCQ-1.2/30-D48N-C  
UCQ-1.5/25-D48N-C  
UCQ-1.5/40-D48N-C  
UCQ-1.8/30-D48N-C  
UCQ-2.5/40-D24P-C  
UCQ-2.5/30-D48N-C  
UCQ-3.3/35-D24P-C  
UCQ-3.3/20-D48N-C  
UCQ-3.3/30-D48N-C  
UCQ-5/20-D24P-C  
UCQ-5/20-D48N-C  
UCQ-5/25-D48N-C  
UCQ-8/12-D24P-C  
UCQ-12/8.3-D48N-C  
UCQ-15/6.7-D24P-C  
1.2  
1.2  
1.5  
1.5  
1.8  
2.5  
2.5  
3.3  
3.3  
3.3  
5
40  
30  
25  
40  
30  
40  
30  
35  
20  
30  
20  
20  
25  
12  
8.3  
48  
36  
Please contact Murata Power Solutions for further information.  
50  
50  
50  
100  
80  
50  
30  
50  
50  
50  
35  
100  
80  
0.125%  
0.125%  
0.125%  
0.125%  
0.125%  
0.2%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
48  
48  
48  
48  
24  
48  
24  
48  
48  
24  
48  
36-75  
36-75  
36-75  
36-75  
18-36  
36-75  
18-36  
36-75  
36-75  
18-36  
36-75  
30  
50  
0.90  
0.94  
1.45  
1.31  
4.96  
1.80  
5.41  
1.53  
2.3  
81%  
81%  
85%  
83%  
82%  
85%  
87%  
88.5%  
90%  
88%  
89%  
83%  
83%  
86%  
86%  
84%  
87%  
89%  
90%  
91%  
91.5%  
93%  
37.5  
60  
100  
TBD  
120  
100  
50  
50  
54  
45  
100  
75  
120  
50  
115.5  
66  
0.125%  
0.125%  
0.2%  
130  
50  
80  
99  
80  
50  
100  
100  
125  
96  
60  
0.125%  
0.125%  
160  
80  
4.55  
2.24  
5
55  
5
Please contact Murata Power Solutions for further information.  
0.2% 0.25% 48 36-75 80 2.28  
Please contact Murata Power Solutions for further information.  
8
12  
15  
99.6  
100  
150  
90%  
91%  
6.7 100.5  
Please refer to the part number structure for additional ordering part numbers and options.  
All specifications are at nominal line voltage and full load, +25 deg.C unless otherwise noted. See detailed specifications. Output capacitors are 1 µF ceramic || 10 µF electrolytic. I/O caps are necessary for  
our test equipment and may not be needed for your application.  
Outline dimensions: 2.3 × 1.45 × 0.39 inches  
58.4 × 36.8 × 9.9 mm  
Pinout: P32 (all models)  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 2 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
PART NUMBER STRUCTURE  
U CQ - 3.3 / 35 D48 N B H - C  
-
Output  
Configuration:  
Unipolar,  
single output  
RoHS Hazardous Materials compliance  
C = RoHS-6 (no lead), standard  
Y = RoHS-5 (with lead), optional, special order  
Quarter-Brick Package  
Nominal Output Voltage  
Conformal coating (optional)  
Blank = no coating, standard  
H = coating added, optional special order  
Baseplate (optional)  
Maximum Rated Output :  
Current in Amps  
Blank = No baseplate, standard  
B = Baseplate installed, optional special order  
Input Voltage Range:  
D24 = 18-36 Volts (24V nominal)  
D48 = 36-75 Volts (48V nominal)  
On/Off Control Polarity  
P = Positive polarity (standard for D24, optional for D48)  
N = Negative polarity (standard for D48, optional for D24)  
Note: Some model combinations  
may not be available. Contact Murata  
Power Solutions for availability.  
MECHANICAL SPECIFICATIONS  
0.40  
(10.2)  
UCQ with Optional Baseplate  
2.30 (58.4)  
A
2.30 (58.4)  
A
1.860 (47.2)  
A
PINS 1-3, 5-7:  
0.040Ø 0.001 (1.016 0.025)  
PINS 4, 8:  
0.015 minimum  
clearance between  
standoffs and  
#M3 THD. X 0.15 DEEP  
TYPICAL 4 PL.  
0.18  
(4.6)  
0.060Ø 0.001 (1.524 0.025)  
highest component  
SCREW LENGTH MUST  
NOT GO THROUGH BASEPLATE  
2.00 (50.8)  
A
4
1
2
3
0.50  
(12.7)  
5
6
7
8
0.600  
(15.2)  
Case C67  
0.300  
(7.6)  
BOTTOM VIEW  
PINS 1-3, 5-7:  
0.040Ø 0.001 (1.016 0.025)  
PINS 4, 8:  
0.600 (15.24)  
4 EQ. SP.  
0.18  
(4.6)  
0.060Ø 0.001 (1.524 0.025)  
Dimensions are in inches (mm shown for ref. only).  
Component locations may vary between units.  
Third Angle Projection  
I/O Connections  
Pin  
1
Function P32  
−Input  
Pin  
5
Function P32  
−Sense  
Tolerances (unless otherwise specified):  
.XX ꢀ.ꢀ0 (ꢀ.ꢁ)  
.XXX ꢀ.ꢀꢂꢀ (ꢀ.0ꢁ)  
Angles 02  
2
Remote On/Off  
+Input  
6
Output Trim  
+Sense  
3
7
4
−Output  
8
+Output  
Components are shown for reference only.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 3 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Performance Specifications and Ordering Guide ➀  
UCQ-1.2/30-D48 UCQ-1.5/25-D48 UCQ-1.5/40-D48 UCQ-1.8/30-D48 UCQ-2.5/40-D24 UCQ-2.5/30-D48 UCQ-3.3/35-D24  
Input  
Input voltage range  
Start-up threshold, Volts  
See ordering guide.  
34  
33  
34  
32  
34  
34  
16.8  
15  
34  
32  
17  
15  
Undervoltage  
shutdown, V  
32.5  
32.5  
none  
Overvoltage shutdown  
Reflected (back) ripple  
current, mA pk-pk  
10-30, model dependent  
Input Current  
Full load conditions  
Inrush transient, A2sec  
Output short circuit, mA  
No load, mA  
See ordering guide.  
0.05  
50-200, model dependent  
30-160, model dependent  
Low line (Vin = min.),  
Amps  
1.23  
1.26  
L-C  
1.96  
1.74  
6.69  
L-C  
2.39  
L-C  
7.21  
L-C  
Standby mode, mA  
(Off, UV, OT shutdown)  
1-10, model dependent  
Pi-type  
Internal input filter type  
Pi-type  
Pi-type  
Reverse polarity  
protection  
See notes.  
Remote On/Off Control  
Positive logic  
OFF = Ground pin to +0.8V  
(P model suffix)  
ON = Open or +3.5 to +13.5V max  
Negative logic  
(N model suffix)  
OFF = Open or +3.5 to +13.5V  
ON = Ground pin to +1V max  
Current, mA  
1
Output  
Voltage output range  
Voltage output accuracy  
See ordering guide.  
1% of Vn o m ., (50% load)  
Adjustment range,  
% of Vn o m .  
10%  
−20 + 10  
10%  
10%  
−20 + 10  
−20 + 10  
10%  
Temperature coefficient  
Minimum loading  
0.02% of Vo u t range per °C  
No minimum loading.  
Remote sense  
compensation  
+10%  
Ripple/noise  
(20 MHz bandwidth)  
See ordering guide.  
Line/Load regulation  
Efficiency  
See ordering guide.  
See ordering guide.  
Maximum capacitive  
loading, µF low ESR  
<0.02Ω max.,  
1,000  
10,000 max.  
10,000  
4,700  
10,000  
10,000 max.  
10,000  
resistive load  
Specs are typical unless noted.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 4 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Performance Specifications and Ordering Guide ➀  
UCQ-3.3/20-D48 UCQ-3.3/30-D48 UCQ-5/20-D24  
UCQ-5/20-D48 UCQ-12/8.3-D48  
Input  
Input voltage range  
Start-up threshold, Volts  
See ordering guide  
35  
34  
35  
34  
17  
35  
34  
35  
34  
Undervoltage  
shutdown, V  
16  
none  
Overvoltage shutdown  
Reflected (back) ripple  
current, mA pk-pk  
10-30, model dependent.  
Input Current  
Full load conditions  
Inrush transient, A2sec  
Output short circuit, mA  
No load, mA  
See ordering guide.  
0.05  
50-200, model dependent  
30-160, model dependent  
Low line (Vin = min.),  
Amps  
2.04  
L-C  
3.05  
L-C  
6.04  
3.02  
L-C  
3.04  
L-C  
Standby mode, mA  
(Off, UV, OT shutdown)  
1-10, model dependent  
Internal input filter type  
L-C  
Reverse polarity  
protection  
See notes.  
Remote On/Off Control  
Positive logic  
OFF = Ground pin to +0.8V  
(P model suffix)  
ON = Open or +3.5 to +13.5V max  
Negative logic  
(N model suffix)  
OFF = Open or +3.5 to +13.5V  
ON = Ground pin to +1V max  
Current, mA  
1
Output  
Voltage output range  
Voltage output accuracy  
See ordering guide.  
1% of Vn o m ., (50% load)  
Adjustment range,  
% of Vn o m .  
−10 to + 10%  
Temperature coefficient  
Minimum loading  
0.02% of Vo u t range per °C.  
No minimum loading.  
Remote sense  
compensation  
+10%  
Ripple/noise  
(20 MHz bandwidth)  
See ordering guide.  
Line/Load regulation  
Efficiency  
See ordering guide.  
See ordering guide.  
Maximum capacitive  
loading, µF low ESR  
<0.02Ω max.,  
10,000  
10,000  
10,000  
10,000  
10,000  
resistive load  
Specs are typical unless noted.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 5 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Performance Specifications and Ordering Guide ➀  
UCQ-1.2/30-D48 UCQ-1.5/25-D48 UCQ-1.5/40-D48 UCQ-1.8/30-D48 UCQ-2.5/40-D24 UCQ-2.5/30-D48 UCQ-3.3/35-D24  
Isolation Voltage  
Input to Output,  
Volts min.  
2250  
1500  
1500  
Input to baseplate,  
Volts min.  
Baseplate to output,  
Volts min.  
Isolation resistance, MΩ  
Isolation capacitance, pF  
Isolation safety rating  
Miscellaneous  
10-100, model dependent  
1000  
Basic insulation  
Current limit inception  
(98% of Vo u t , after  
warmup), Amps  
35  
35  
49  
36  
46  
37  
45  
Short circuit protection  
method  
Current limiting, hiccup autorestart. Remove overload for recovery.  
Short circuit current,  
Amps  
5
Short circuit duration  
Continuous, output shorted to ground. No damage.  
Overvoltage protection,  
Volts (via magnetic  
feedback)  
1.8  
1.8  
1.95  
2.7 V max  
2.95  
2.95  
4
Dynamic characteristics  
Dynamic load response 200 µSec to 1% 200 µSec to 1% 50 µSec to 1% of 100 µSec to 1% 200 µSec to 1% 200 µSec to 1% 100 µSec to 1%  
(50-75-50% load step) of final value  
of final value  
final value  
of final value  
of final value  
of final value  
of final value  
Start-up time  
Vin to Vo u t regulated,  
mSec  
50  
50  
50  
50  
50  
50  
2
Remote On/Off to Vo u t  
50  
50  
50  
50  
50  
50  
3
regulated, mSec  
Switching frequency, KHz  
350 20  
440 40  
400 40  
400  
480  
450 30  
350 10  
Environmental  
Calculated MTBF  
TBD  
2.2M hours  
TBD  
Operating temperature  
range  
−40 to +85, with derating  
See Derating curves.  
Operating case  
temperature, °C"  
(no derating)  
−40 to +110  
−40 to +120  
−40 to +110  
Storage temperature  
range, °C  
−55 to +125  
Thermal protection/  
shutdown, °C  
110-125, model dependent  
Relative humidity  
To +85°C/85%, non-condensing  
Specs are typical unless noted.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 6 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Performance Specifications and Ordering Guide ➀  
UCQ-3.3/20-D48 UCQ-3.3/30-D48 UCQ-5/20-D24  
UCQ-5/20-D48 UCQ-12/8.3-D48  
Isolation Voltage  
Input to Output,  
Volts min.  
2250  
1500  
1500  
Input to baseplate,  
Volts min.  
Baseplate to output,  
Volts min.  
Isolation resistance, MΩ  
Isolation capacitance, pF  
Isolation safety rating  
10-100, model dependent  
1000  
Basic insulation  
Current limit inception  
(98% of Vo u t , after  
warmup), Amps  
24 min.  
33 min.  
26  
22 min.  
10  
Short circuit protection  
method  
Current limiting, hiccup autorestart. Remove overload for recovery.  
Short circuit current,  
Amps  
5
Short circuit duration  
Continuous, output shorted to ground. No damage.  
Overvoltage protection,  
Volts (via magnetic  
feedback)  
4.6 max.  
4 max.  
6.25  
TBD  
14.4  
Dynamic characteristics  
Dynamic load response 200 µSec to 1% 200 µSec to 1% 200 µSec to 1% 200 µSec to 1% 200 µSec to 1%  
(50-75-50% load step) of final value  
of final value  
of final value  
of final value  
of final value  
Start-up time  
Vin to Vo u t regulated,  
mSec  
50  
50 max.  
4
10 max.  
50  
Remote On/Off to Vo u t  
50  
50 max.  
4
10 max.  
50  
regulated, mSec  
Switching frequency, KHz  
330 40  
330 40  
400 24  
315 30  
330 40  
Environmental  
Calculated MTBF  
TBD  
Operating temperature  
range  
−40 to +85, with derating  
See Derating curves.  
Operating case  
temperature, °C"  
(no derating)  
−40 to +110  
Storage temperature  
range, °C  
−55 to +125  
Thermal protection/  
shutdown, °C  
110-125, model dependent  
Relative humidity  
To +85°C/85%, non-condensing  
Specs are typical unless noted.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 7 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Performance Specifications and Ordering Guide ➀  
UCQ-1.2/30-D48 UCQ-1.5/25-D48 UCQ-1.5/40-D48 UCQ-1.8/30-D48 UCQ-2.5/40-D24 UCQ-2.5/30-D48 UCQ-3.3/35-D24  
Physical  
Outline dimensions  
Pin material  
Pin diameter  
Pin finish  
See mechanical specs.  
Copper alloy  
0.04/0.062 inches (1.016/1.524 mm)  
Nickel underplate with gold overplate  
Weight, ounces  
Weight, grams  
1.06  
30  
1.06  
30  
0.9  
25  
0.9  
1.06  
30  
1.06  
30  
1.02  
29  
25  
Electromagnetic  
interference  
FCC part 15, class B, EN55022  
(Conducted and radiated. External filter required)  
Safety  
UL 60950-1, CSA C22.2 No.60950-1, IEC/EN 60950-1  
UCQ-3.3/20-D48 UCQ-3.3/30-D48 UCQ-5/20-D24  
UCQ-5/20-D48 UCQ-12/8.3-D48  
Physical  
Outline dimensions  
Pin material  
See mechanical specs.  
Copper alloy  
Pin diameter  
Pin finish  
0.04/0.062 inches (1.016/1.524 mm)  
Nickel underplate with gold overplate  
Weight, ounces  
Weight, grams  
0.7  
20  
TBD  
TBD  
1.06  
TBD  
TBD  
1.13  
32  
30  
Electromagnetic  
interference  
FCC part 15, class B, EN55022  
(Conducted and radiated. External filter required)  
Safety  
UL 60950-1, CSA C22.2 No.60950-1, IEC/EN 60950-1  
Caution: This product is not internally fused. To comply with safety agency certifications and to avoid injury to personnel or equipment, the user must supply an external fast-blow fuse to the input terminals.  
See fuse information.  
Specification Notes  
(1) All models are tested and specified with external 1||10 µF ceramic/tantalum output capacitors no external input capacitor. All capacitors are low ESR types. These capacitors are necessary to accom-  
modate our test equipment and may not be required to achieve specified performance in your applications. All models are stable and regulate within spec under no-load conditions. All specifications are  
typical unless noted. General conditions for Specifications are +25 deg.C, Vin and Vo u t = nominal, full load. Adequate airflow must be supplied for extended testing under power.  
(2) Input Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is Cin = 33 µF, 100V tantalum, Cb u s = 220 µF, 100V electrolytic, Lb u s = 12 µH.  
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if  
the total RMS current over time does not exceed the Derating curve. All Derating curves are presented at sea level altitude. Be aware of reduced power dissipation with increasing density altitude.  
(4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fixed conditions, Tpcboard = +25 deg.C, full output load, natural air convection.  
(5) The On/Off Control is normally controlled by a switch or open collector or open drain transistor. But it may also be driven with external logic or by applying appropriate external voltages which are  
referenced to Input Common.  
(6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting.  
(7) The outputs are not intended to sink appreciable reverse current. This may damage the outputs.  
(8) Output noise may be further reduced by adding an external filter. See I/O Filtering and Noise Reduction.  
(9) All models are fully operational and meet published specifications, including “cold start” at –40 C.  
(10) Regulation specifications describe the deviation as the line input voltage or output load current is varied from a nominal midpoint value to either extreme.  
(11) Output accuracy is dependent on user-supplied trim resistors. To achieve high accuracy, use 1% or better tolerance metal-film resistors mounted close to the converter.  
(12) Output current limit and short circuit protection is non-latching. When the overcurrent fault is removed, the converter will immediately recover.  
(13) Do not exceed maximum power specifications when adjusting the output trim.  
(14) At zero output current, the output may contain low frequency components which exceed the ripple specification. The output may be operated indefinitely with no load.  
(15) Input Fusing: If reverse polarity is accidentally applied to the input, a body diode will become forward biased and will conduct considerable current. To ensure reverse input protection with full output load,  
always connect an external input fast-blow fuse in series with the +Vin input. Use approximately twice the full input current rating with nominal input voltage.  
(16) “Hiccup” overcurrent operation repeatedly attempts to restart the converter with a brief, full-current output. If the overcurrent condition still exists, the restart current will be removed and then tried again.  
This short current pulse prevents overheating and damaging the converter. Once the fault is removed, the converter immediately recovers normal operation.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 8 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
The On/Off Control to VOUT start-up time assumes the converter has its  
nominal input voltage applied but is turned off via the On/Off Control pin. The  
specification defines the interval between the point at which the converter is  
turned on (released) and the fully loaded output voltage enters and remains  
within its specified accuracy band. Similar to the VIN to VOUT start-up, the On/Off  
Control to VOUT start-up time is also governed by the internal soft start circuitry  
and external load capacitance. The difference in start up time from VIN to VOUT  
and from On/Off Control to VOUT is therefore insignificant.  
Absolute Maximum Ratings  
Input Voltage  
Continuous  
Transient (100msec)  
24V Models  
0 to +36 Volts  
+50 Volts  
48V Models  
0 to +75 Volts  
+100 Volts  
On/Off Control  
0V min. to +13.5V max.  
See Fuse section  
TBD  
Current-limited. Devices can withstand  
sustained short circuit without damage.  
–40 to +100°C  
Input Reverse Polarity Protection  
Output Overvoltage  
Output Current  
Operating Temperature  
Storage Temperature  
Lead Temperature (soldering 10 sec. max.) +280°C  
Input Source Impedance  
–55 to +125°C  
The input of UCQ converters must be driven from a low ac-impedance source.  
The DC/DC’s performance and stability can be compromised by the use of  
highly inductive source impedances. The input circuit shown in Figure 2 is a  
practical solution that can be used to minimize the effects of inductance in the  
input traces. For optimum performance, components should be mounted close  
to the DC/DC converter.  
These are stress ratings. Exposure of devices to any of these conditions may adversely  
affect long-term reliability. Proper operation under conditions other than those listed in the  
Performance/Functional Specifications Table is not implied, nor recommended.  
Input Fusing  
Certain applications and/or safety agencies may require the installation of  
fuses at the inputs of power conversion components. Fuses should also be  
used if the possibility of sustained, non-current-limited, input-voltage polarity  
reversals exists. For DATEL UCQ series DC/DC converters, we recommend the  
use of a time delay fuse, installed in the ungrounded input supply line.  
I/O Filtering, Input Ripple Current, and Output Noise  
All models in the UCQ Series are tested/specified for input reflected ripple  
current and output noise using the specified external input/output compo-  
nents/circuits and layout as shown in the following two figures. External input  
capacitors (CIN in Figure 2) serve primarily as energy-storage elements, mini-  
mizing line voltage variations caused by transient IR drops in conductors from  
backplane to the DC/DC. Input caps should be selected for bulk capacitance  
(at appropriate frequencies), low ESR, and high rms-ripple-current ratings. The  
switching nature of DC/DC converters requires that dc voltage sources have  
low ac impedance as highly inductive source impedance can affect system sta-  
bility. In Figure 2, CBUS and LBUS simulate a typical dc voltage bus. Your specific  
system configuration may necessitate additional considerations.  
As a rule of thumb however, we recommend the use of a normal-blow or  
slow-blow fuse with a typical value about twice the maximum input current,  
calculated at low line with the converter’s minimum efficiency.  
All relevant national and international safety standards and regulations must  
be observed by the installer. For system safety agency approvals, the convert-  
ers must be installed in compliance with the requirements of the end- use  
safety standard, i.e. IEC/EN/UL60950-1.  
TO  
Input Reverse-Polarity Protection  
CURRENT  
PROBE  
OSCILLOSCOPE  
If the input voltage polarity is accidentally reversed, an internal diode will  
become forward biased and likely draw excessive current from the power  
source. If this source is not current limited or the circuit appropriately fused, it  
could cause permanent damage to the converter.  
3
1
+INPUT  
–INPUT  
L
BUS  
+
V
IN  
C
BUS  
CIN  
Input Under-Voltage Shutdown and Start-Up Threshold  
Under normal start-up conditions, devices will not begin to regulate properly  
until the ramping-up input voltage exceeds the Start-Up Threshold Voltage.  
Once operating, devices will not turn off until the input voltage drops below the  
Under-Voltage Shutdown limit. Subsequent re-start will not occur until the input  
is brought back up to the Start-Up Threshold. This built in hysteresis prevents  
any unstable on/off situations from occurring at a single input voltage.  
C
C
IN = 33µF, ESR < 700m@ 100kHz  
BUS = 220µF, ESR < 100m@ 100kHz  
LBUS = 12µH  
Figure 2. Measuring Input Ripple Current  
In critical applications, output ripple/noise (also referred to as periodic and  
random deviations or PARD) may be reduced below specified limits using filter-  
ing techniques, the simplest of which is the installation of additional external  
output capacitors. They function as true filter elements and should be selected  
for bulk capacitance, low ESR and appropriate frequency response.  
Start-Up Time  
The VIN to VOUT Start-Up Time is the time interval between the point at which  
the ramping input voltage crosses the Start-Up Threshold and the fully loaded  
output voltage enters and remains within its specified accuracy band. Actual  
measured times will vary with input source impedance, external input capaci-  
tance, and the slew rate and final value of the input voltage as it appears at the  
converter. The UCQ Series implements a soft start circuit to limit the duty cycle  
of its PWM controller at power up, thereby limiting the input inrush current.  
All external capacitors should have appropriate voltage ratings and be  
located as close to the converter as possible. Temperature variations for all  
relevant parameters should also be taken carefully into consideration. The most  
effective combination of external I/O capacitors will be a function of line volt-  
age and source impedance, as well as particular load and layout conditions.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 9 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
In Figure 3, the two copper strips simulate real-world PCB impedances  
between the power supply and its load. In order to minimize measurement  
errors, scope measurements should be made using BNC connectors, or the  
probe ground should be less than ½ inch and soldered directly to the fixture.  
commonly referred to as power limiting. Current limit inception is defined  
as the point at which the full-power output voltage falls below the specified  
tolerance. See Performance/Functional Specifications. If the load current, being  
drawn from the converter, is significant enough, the unit will go into a short  
circuit condition as described below.  
7
COPPER STRIP  
+SENSE  
Short Circuit Condition  
8
When a converter is in current-limit mode, the output voltage will drop as the  
output current demand increases. If the output voltage drops too low, the mag-  
netically coupled voltage used to develop primary side voltages will also drop,  
thereby shutting down the PWM controller. Following a time-out period, the  
PWM will restart causing the output voltage to begin ramping to their appropri-  
ate value. If the short-circuit condition persists, another shutdown cycle will be  
initiated. This on/off cycling is referred to as “hiccup” mode. The hiccup cycling  
reduces the average output current, thereby preventing internal temperatures  
from rising to excessive levels. The UCQ Series is capable of enduring an  
indefinite short circuit output condition.  
+OUTPUT  
R
LOAD  
SCOPE  
C1  
C2  
4
5
–OUTPUT  
–SENSE  
COPPER STRIP  
C1 = 1µF CERAMIC  
C2 = 10µF TANTALUM  
LOAD 2-3 INCHES (51-76mm) FROM MODULE  
Remote Sense  
Figure 3. Measuring Output Ripple/Noise (PARD)  
Note: The Sense and VOUT lines are internally connected through low-value  
resistors. Nevertheless, if the sense function is not used for remote regulation  
the user should connect the +Sense to +VOUT and –Sense to –VOUT at the DC/  
DC converter pins. UCQ series converters employ a sense feature to provide  
point of use regulation, thereby overcoming moderate IR drops in PCB conduc-  
tors or cabling. The remote sense lines carry very little current and therefore  
require minimal cross-sectional-area conductors. The sense lines, which are  
capacitively coupled to their respective output lines, are used by the feedback  
control-loop to regulate the output. As such, they are not low impedance points  
and must be treated with care in layouts and cabling. Sense lines on a PCB  
should be run adjacent to dc signals, preferably ground.  
Floating Outputs  
Since these are isolated DC/DC converters, their outputs are “floating” with  
respect to their input. Designers will normally use the –Output (pin 4) as the  
ground/return of the load circuit. You can however, use the +Output (pin 8) as  
ground/return to effectively reverse the output polarity.  
Minimum Output Loading Requirements  
UCQ converters employ a synchronous-rectifier design topology and all models  
regulate within spec and are stable under no-load to full load conditions.  
Operation under no-load conditions however might slightly increase the output  
ripple and noise.  
[VOUT(+)-VOUT(–)] – [Sense(+)-Sense(–)] 10%VOUT  
Thermal Shutdown  
The UCQ converters are equipped with thermal-shutdown circuitry. If environ-  
mental conditions cause the temperature of the DC/DC converter to rise above  
the designed operating temperature, a precision temperature sensor will power  
down the unit. When the internal temperature decreases below the threshold  
of the temperature sensor, the unit will self start. See Performance/Functional  
Specifications.  
#ONTACT AND 0#" RESISTANCE  
LOSSES DUE TO )2 DROPS  
ꢀ/54054  
n).054  
)/54  
ꢀ3%.3%  
3ENSE #URRENT  
Output Over-Voltage Protection  
/.ꢁ/&&  
#/.42/,  
42)-  
n3%.3%  
,/!$  
The UCQ output voltage is monitored for an over-voltage condition using a com-  
parator. The signal is optically coupled to the primary side and if the output volt-  
age rises to a level which could be damaging to the load, the sensing circuitry  
will power down the PWM controller causing the output voltage to decrease.  
Following a time-out period the PWM will restart, causing the output voltage  
to ramp to its appropriate value. If the fault condition persists, and the output  
voltage again climbs to excessive levels, the over-voltage circuitry will initiate  
another shutdown cycle. This on/off cycling is referred to as “hiccup” mode.  
3ENSE 2ETURN  
)/54 2ETURN  
ꢀ).054  
n/54054  
#ONTACT AND 0#" RESISTANCE  
LOSSES DUE TO )2 DROPS  
Figure 4. Remote Sense Circuit Configuration  
Current Limiting  
As soon as the output current increases to approximately 130% of its rated  
value, the DC/DC converter will go into a current-limiting mode. In this condi-  
tion, the output voltage will decrease proportionately with increases in output  
current, thereby maintaining somewhat constant power dissipation. This is  
In cables and discrete wiring applications, twisted pair or other techniques  
should be used. Output over-voltage protection is monitored at the output volt-  
age pin, not the Sense pin. Therefore, excessive voltage differences between  
VOUT and Sense in conjunction with trim adjustment of the output voltage can  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 10 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
cause the over-voltage protection circuitry to activate (see Performance Speci-  
fications for over-voltage limits). Power derating is based on maximum output  
current and voltage at the converter’s output pins. Use of trim and sense func-  
tions can cause output voltages to increase, thereby increasing output power  
beyond the converter’s specified rating, or cause output voltages to climb into  
the output over-voltage region. Therefore, the designer must ensure:  
ꢀ/54054  
n).054  
ꢀ3%.3%  
42)-  
/.ꢁ/&&  
#/.42/,  
,/!$  
242)- $/7.  
(VOUT at pins) x (IOUT) rated output power  
n3%.3%  
n/54054  
Trimming Output Voltage  
ꢀ).054  
UCQ converters have a trim capability (pin 6) that enables users to adjust the  
output voltage (refer to the trim equations and trim graphs that follow). Adjust-  
ments to the output voltage can be accomplished via a trim pot (Figure 5) or  
a single fixed resistor as shown in Figures 6 and 7. A single fixed resistor can  
increase or decrease the output voltage depending on its connection. Resistors  
should be located close to the converter and have TCR’s less than 100ppm/°C  
to minimize sensitivity to changes in temperature. If the trim function is not  
used, leave the trim pin open.  
Figure 7.Trim Connections To Decrease Output Voltages Using Fixed Resistors  
A single resistor connected from the Trim pin (pin 6) to the +Sense (pin 7)  
will increase the output voltage. A resistor connected from the Trim Pin (pin 6)  
to the –Sense (pin 5) will decrease the output voltage.  
Trim Equations  
(For all models except the UCQ-1.2/40-D24 and -1.2/30-D48)  
ꢃ/54054  
n).054  
Trim Down  
Connect trim resistor between  
Trim Up  
Connect trim resistor between  
ꢃ3%.3%  
trim pin and −Sense  
trim pin and +Sense  
ꢀꢁꢂꢂ  
452.3  
/.ꢄ/&&  
#/.42/,  
42)-  
n3%.3%  
,/!$  
5.11 × VNOM × (1+  
5.11  
− 5.11  
R
TrimDn (k Ω) =  
RTrimUp (k Ω) =  
− 10.22  
− 10.22  
1.225 ×   
Where,  
   VNOM − VOUT) / VNOM   
VNOM is the nominal, untrimmed output voltage.  
ꢃ).054  
n/54054  
VOUT is the desired new output voltage.  
Figure 5.Trim Connections Using A Trimpot  
Do not exceed the specified trim range or maximum power ratings  
when adjusting trim. Use 1% precision resistors mounted close  
to the converter on short leads.  
(For the UCQ-1.2/40-D24 and -1.2/30-D48)  
ꢀ/54054  
n).054  
Trim Down  
Connect trim resistor between  
Trim Up  
Connect trim resistor between  
ꢀ3%.3%  
trim pin and −Sense  
trim pin and +Sense  
/.ꢁ/&&  
#/.42/,  
42)-  
,/!$  
5.11 × VNOM × (1+  
5.11  
R
TrimDn (k Ω) =  
R
TrimUp (k Ω) =  
242)- 50  
2− 2  
1.225 ×   
n3%.3%  
Trim adjustments greater than the specified range can have an adverse  
ꢀ).054  
n/54054  
affect on the converter’s performance and are not recommended. Excessive  
voltage differences between VOUT and Sense, in conjunction with trim adjust-  
ment of the output voltage, can cause the over-voltage protection circuitry to  
activate (see Performance Specifications for over-voltage limits). Temperature/  
power derating is based on maximum output current and voltage at the  
converter’s output pins. Use of the trim and sense functions can cause output  
voltages to increase, thereby increasing output power beyond the converter’s  
specified rating, or cause output voltages to climb into the output over-voltage  
region. Therefore:  
Figure 6.Trim Connections To Increase Output Voltages Using Fixed Resistors  
(Vo u t at pins) x (Io u t ) rated output power  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 11 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Typical Performance Curves  
The Trim pin (pin 6) is a relatively high impedance node that can be suscep-  
tible to noise pickup when connected to long conductors in noisy environments.  
In such cases, a 0.22µF capacitor between trim and –Vo u t can be added to  
reduce this long lead effect.  
5#1ꢀꢁꢂꢁꢃꢁꢄꢀ$ꢅꢆ /UTPUT 4RANSIENT 2ESPONSE  
ꢀ6). ꢁ ꢂꢃ6RESISTIVE LOAD STEP ꢅꢆꢇ TO ꢆꢈꢇꢉ  
On/Off Control  
The input-side, remote On/Off Control function (pin 2) can be ordered to operate  
with either polarity:  
Positive (no suffix): standard models are equipped with Positive-polarity and  
are enabled when pin 2 is left open (or is pulled high, applying +3.5V to +13.5V  
with respect to –Input, pin 1) as per Figure 8. Positive-polarity devices are  
disabled when pin 2 is pulled low (0 to 0.8V with respect to –Input).  
ꢊꢈꢈ§SECꢋDIV  
ꢃ).054  
5#1ꢀꢁꢂꢁꢃꢁꢄꢀ$ꢅꢆ /UTPUT 4RANSIENT 2ESPONSE  
ꢀ6). ꢁ ꢂꢃ6RESISTIVE LOAD STEP ꢅꢆꢇ TO ꢈꢅꢇꢉ  
ꢂꢀ6 #)2#5)4  
ꢄ6 #)2#5)4  
/.ꢅ/&&  
#/.42/,  
n).054  
Figure 8. Driving the Negative Polarity On/Off Control Pin  
Negative (“N” suffix): Optional Negative-polarity devices are off when pin 2  
is left open (or pulled high, applying +3.5V to +13.5V), and on when pin 2 is  
pulled low (0 to 1V) with respect to –Input as shown in Figure 9.  
ꢊꢆꢆ§SECꢋDIV  
5#1ꢀꢁꢂꢁꢃꢁꢄꢀ$ꢅꢆ %NABLE /Nꢃ/FF  
ꢀ6). ꢁ ꢂꢃ6)/54 ꢁ ꢅꢆ!ꢇ  
ꢃ).054  
ꢃ6##  
6/54  
ꢈ6ꢉDIV  
/.ꢄ/&&  
#/.42/,  
#ONTROL  
0IN  
ꢊ6ꢉDIV  
n).054  
ꢊMSECꢉDIV  
Figure 9. Driving the Negative Polarity On/Off Control Pin  
5#1ꢀꢁꢂꢁꢃꢁꢄꢀ$ꢅꢆ 2IPPLE AND .OISE  
ꢀ6). ꢁ ꢂꢃ6)/54 ꢁ ꢅꢆ! RESISTIVEꢄ OUTPUT CAPS ꢇ§& CERAMIC \\ ꢇꢆ§& TANTALUMꢈ  
Dynamic control of the remote on/off function is best accomplished with a  
mechanical relay or an open-collector/open-drain drive circuit (optically isolated  
if appropriate). The drive circuit should be able to sink appropriate current (see  
Performance Specifications) when activated and withstand appropriate voltage  
when deactivated. Applying an external voltage to pin 2 when no input power is  
applied to the converter can cause permanent damage to the converter.  
ꢋ§SECꢊDIV  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 12 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Typical Performance Curves  
UCQ-1.2/30-D48 Maximum Current Temperature Derating  
No baseplate, VIN = 48V (at sea level), longitudinal airflow  
UCQ-1.2/30-D48 Efficiency vs Line Voltage and Load Current @25˚ C  
95  
35  
30  
25  
20  
90  
85  
80  
75  
70  
VIN = 36V  
400 lfm  
65  
60  
55  
50  
45  
40  
300 lfm  
V
IN = 48V  
15  
10  
5
200 lfm  
V
IN = 75V  
100 lfm  
0
3
6
9
12  
15  
18  
21  
24  
27  
75  
30  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
Load Current (Amps)  
Ambient Temperature ( C)  
°
UCQ-1.5/25-D48 Efficiency vs Line Voltage and Load Current @25˚ C  
UCQ-1.5/25-D48 Maximum Current Temperature Derating  
No baseplate, VIN = 48V (at sea level), longitudinal airflow  
90  
88  
86  
84  
82  
80  
78  
30  
25  
20  
15  
10  
VIN = 75V  
76  
74  
72  
70  
68  
66  
64  
62  
60  
VIN = 48V  
VIN = 36V  
400 lfm  
300 lfm  
200 lfm  
5
100 lfm  
0
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
Load Current (Amps)  
Ambient Temperature ( C)  
°
UCQ-1.8/30-D48 Efficiency vs Line Voltage and Load Current @25˚ C  
UCQ-1.8/30-D48 Maximum Current Temperature Derating  
No baseplate, VIN = 48V (at sea level), longitudinal airflow  
90  
32  
30  
28  
26  
24  
88  
86  
84  
V
IN = 36V  
IN = 48V  
IN = 75V  
82  
80  
78  
76  
74  
72  
70  
V
V
22  
400 lfm  
300 lfm  
200 lfm  
20  
100 lfm  
Natural convection  
18  
4
6
8
10  
12  
14  
16  
18  
20  
22  
24  
26  
28  
30  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
Load Current (Amps)  
Ambient Temperature ( C)  
°
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 13 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Typical Performance Curves  
UCQ-2.5/30-D48 Efficiency vs Line Voltage and Load Current @25˚ C  
UCQ-2.5/30-D48 Maximum Current Temperature Derating  
No baseplate, VIN = 24V (at sea level)  
95  
35  
30  
25  
20  
15  
90  
85  
80  
75  
V
IN = 75V  
70  
65  
60  
55  
50  
45  
40  
V
IN = 48V  
V
IN = 36V  
400 lfm  
10  
300 lfm  
200 lfm  
5
100 lfm  
1
3
6
9
12  
15  
18  
21  
24  
27  
30  
0
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
Load Current (Amps)  
Ambient Temperature ( C)  
°
UCQ-2.5/40-D24 Efficiency vs Line Voltage and Load Current @25˚ C  
UCQ-2.5/40-D24 Maximum Current Temperature Derating  
No baseplate, VIN = 24V (at sea level)  
95  
35  
30  
25  
20  
15  
90  
85  
V
IN = 24V  
80  
75  
70  
65  
60  
55  
50  
V
IN = 18V  
V
IN = 35V  
10  
400 lfm  
300 lfm  
5
200 lfm  
100 lfm  
0
3
6
9
12  
15  
18  
21  
24  
27  
30  
33  
36  
39 40  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
Load Current (Amps)  
Ambient Temperature ( C)  
°
UCQ-3.3/30-D48 Maximum Current Temperature Derating  
No baseplate, VIN = 48V (at sea level)  
UCQ-3.3/30-D48 Efficiency vs Line Voltage and Load Current @25°C  
95  
40  
35  
30  
25  
20  
90  
85  
VIN = 36V  
100 lfm  
15  
80  
75  
70  
V
IN = 50V  
200 lfm  
10  
300 lfm  
V
IN = 75V  
5
400 lfm  
0
85  
25  
30  
35  
40  
45  
50  
Ambient Temperature (°C)  
55  
60  
65  
70  
75  
80  
5
10  
15  
20  
25  
30  
Load Current (Amps)  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 14 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Typical Performance Curves  
UCQ-3.3/30-D48 Maximum Current Temperature Derating  
With baseplate, VIN = 48V (at sea level)  
UCQ-3.3/35-D48 Maximum Current Temperature Derating  
With baseplate, VIN = 48V (transverse air flow at sea level)  
40  
35  
30  
25  
20  
36  
34  
32  
30  
28  
Natural Convection  
100 lfm  
26  
15  
100 lfm  
24  
200 lfm  
10  
200 lfm  
22  
300 lfm  
300 lfm  
5
20  
400 lfm  
400 lfm  
0
18  
35  
40  
45  
50  
Ambient Temperature (°C)  
55  
60  
65  
70  
75  
80  
85  
25  
30  
80  
85  
20  
25  
30  
35  
40  
45  
Ambient Temperature (°C)  
50  
55  
60  
65  
70  
75  
UCQ-3.3/35-D24 Maximum Current Temperature Derating  
No baseplate, VIN = 48V (at sea level), longitudinal airflow  
UCQ-3.3/35-D24 Efficiency vs Line Voltage and Load Current @25˚ C  
92  
35  
30  
25  
20  
15  
90  
88  
86  
84  
VIN = 36V  
VIN = 24V  
VIN = 18V  
82  
80  
78  
76  
74  
72  
70  
400 lfm  
10  
300 lfm  
200 lfm  
5
100 lfm  
0
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
3
5
7
9
11  
15  
17  
19  
21  
23  
25  
27  
29  
31  
33  
35  
Ambient Temperature (°C)  
Load Current (Amps)  
UCQ-5/20-D48  
Efficiency vs Line Voltage and Load Current @25°C  
95  
90  
85  
V
IN = 36V  
80  
75  
70  
VIN = 50V  
VIN = 75V  
4
6
8
10  
12  
14  
16  
18  
20  
Load Current (Amps)  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 15 of 16  
Single Output UCQ Models  
Low-Profile, Quarter Brick, 8.3-40 Amp  
Isolated DC/DC Converters  
Typical Performance Curves  
UCQ-12/8.3-D48 Maximum Current Temperature Derating  
No baseplate, VIN = 48V (at sea level), longitudinal airflow  
UCQ-12/8.3-D48 Efficiency vs Line Voltage and Load Current @25˚ C  
96  
9
94  
92  
90  
8
7
6
5
VIN = 75V  
VIN = 48V  
VIN = 36V  
88  
84  
82  
80  
78  
76  
74  
72  
70  
4
400 lfm  
300 lfm  
3
200 lfm  
100 lfm  
2
1
0
0
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
0.8  
1.6  
2.4  
3.2  
4
4.8  
5.6  
6.4  
7.2  
8.3  
Ambient Temperature ( C)  
°
Load Current (Amps)  
USA:  
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com  
Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com  
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com  
Canada:  
UK:  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356  
www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED  
0058//0199//0088  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
France:  
Germany:  
Japan:  
Montigny Le Bretonneux,Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com  
München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com  
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com  
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com  
China:  
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com  
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com  
notice.  
© 2008 Murata Power Solutions, Inc.  
Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UCQ Models.B07 Page 16 of 16  

相关型号:

UCQ-3.3/20-D48N-C

Low-Profile, Quarter Brick, 8.3-40 Amp Isolated DC/DC Converters
MURATA

UCQ-3.3/20-D48NBHL2-C

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-8
MURATA

UCQ-3.3/20-D48NL1-C

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid, ROHS COMPLIANT, QUARTER-BRICK PACKAGE-8
MURATA

UCQ-3.3/20-D48NL2-C

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid, ROHS COMPLIANT, QUARTER-BRICK PACKAGE-8
MURATA

UCQ-3.3/30-48NB

二次电源-1/4砖-82.5W--40degC-100degC-36V-75V-80%~110%Vout-负逻辑-3.3V/25A-0A-30000uF
ETC

UCQ-3.3/30-D48N-C

Low-Profile, Quarter Brick, 8.3-40 Amp Isolated DC/DC Converters
MURATA

UCQ-3.3/30-D48NB-C

DC-DC Regulated Power Supply Module, 1 Output, 99W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-8
MURATA

UCQ-3.3/35-D24P-C

Low-Profile, Quarter Brick, 8.3-40 Amp Isolated DC/DC Converters
MURATA

UCQ-3.3/35-D24PB-C

DC-DC Regulated Power Supply Module, 1 Output, 115.5W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-8
MURATA

UCQ-3.3/35-D24PB-Y

DC-DC Regulated Power Supply Module, 1 Output, 115.5W, Hybrid, QUARTER BRICK PACKAGE-8
MURATA

UCQ-3.3/35-D24PBH-C

DC-DC Regulated Power Supply Module, 1 Output, 115.5W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-8
MURATA

UCQ-3.3/35-D24PHL1-Y

DC-DC Regulated Power Supply Module, 1 Output, 115.5W, Hybrid, QUARTER-BRICK PACKAGE-8
MURATA