UHP-28.2/12-D48P [MURATA]

DC-DC Regulated Power Supply Module, 1 Output, 342W, Hybrid, HALF BRICK PACKAGE-9;
UHP-28.2/12-D48P
型号: UHP-28.2/12-D48P
厂家: muRata    muRata
描述:

DC-DC Regulated Power Supply Module, 1 Output, 342W, Hybrid, HALF BRICK PACKAGE-9

文件: 总9页 (文件大小:828K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
UHP-28.2/12-D48  
k, 48VIN/28.2VOUT DC/DC Converters  
OBSOLETE PRODUCT  
N Range  
Ripple/Noise  
Efficiency  
36-75V  
100mVp-p  
91.5%  
INPUT CHARACTERISTICS  
Parameter  
Typ. @ 25°C, full load  
36-75 Volts  
5.77 Amps  
32 Volts  
Notes  
Voltage Range  
48V nominal  
VIN = 48V  
Current, full power  
Undervoltage Shutdown  
Short Circuit Current  
Remote On/Off Control  
200mA  
VIN = 48V  
Typical unit  
0 to +VIN  
Positive or negative logic  
FEATURES  
OUTPUT CHARACTERISTICS  
Parameter  
Typ. @ 25°C, full load  
28.2 Volts 10%  
0 to 12 Amps  
342 Watts max.  
1.25%  
Notes  
Wide 36-75V input range  
Voltage  
Trim range shown  
No minimum load  
28.2V output @ 12 Amps. max.  
Current  
Very high efficiency of 91.5%  
Power Output  
Max. baseplate @ 342W = 80°C  
Operates to +110°C baseplate w/derating  
Conduction-cooled baseplate, no fans  
Industry-standard mounting and pinout  
Remote sense, trim and On/Off control  
Isolated to 2250Vdc (Basic insulation)  
Multiple I/O protection features  
Accuracy  
Ripple & Noise  
100mVp-p  
20MHz bandwidth  
Line and Load Regulation  
Overcurrent Protection  
Overtemperature Protection  
Efficiency (minimum)  
Efficiency (typical)  
0.05%/ 0.1%  
30 Amps  
With hiccup auto-restart  
+125°C  
89.5%  
91.5%  
UL/EN60950-1 safety approvals, CE mark  
ETSI 300-019-2-4 surge, shock/vibration  
GENERAL SPECIFICATIONS  
Parameter  
Typ. @ 25°C, full load  
100μsec  
Notes  
Dynamic Load Response  
Operating Temperature Range  
Operating Temperature Range  
Safety  
50-75-50% step to 1 of final value  
With baseplate, see derating curve  
Without baseplate  
DESCRIPTION  
–40 to +110°C  
–40 to +32°C  
The UHP-28.2/12-D48 is especially designed for  
unattended cellular and PCS base stations, remote  
wide band RF amplifiers and wireless communi-  
cation facilities. To avoid unreliable system fans,  
the UHP-28.2/12-D48 can be operated using con-  
duction cooling while attached to a housing wall  
or system heat sink. No forced airflow is needed  
up to +110°C baseplate temperature.  
UL/IEC/EN 60950-1  
And CSA C22.2-No.234  
MECHANICAL CHARACTERISTICS  
With baseplate  
2.30 x 2.40 x 0.502 inches (58.4 x 61.0 x 12.8 mm)  
2.30 x 2.40 x 0.452 inches (58.4 x 61.0 x 11.5 mm)  
Without baseplate  
The UHP-28.2/12-D48's MTBF is 3 million hours  
(+40°C GF) and ruggedization conforms to  
ETSI 300-019-2-4. Multiple protection features  
avoid damage to outside equipment and to the  
converter itself. The converter will shut down on  
sustained input undervoltage, output overcurrent,  
output short circuit and overvoltage and thermal  
shutdown. Overload currents less than a short  
circuit limit the output current so that operation  
is not interrupted. Upon short circuit shutdown,  
the converter will automatically attempt to restart  
(“hiccup” mode) when the overload is removed.  
The input will tolerate up to 100V overvoltage  
spikes (100msec).  
The UHP-28.2/12-D48 uses industry-standard  
half-brick external outline dimensions, pinout and  
mechanical mounting. The overall unit is designed  
to be as “lead-free” as practical in construction  
and method of attachment (no lead added in  
assembly).  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
UHP_28.2/12_D48.B02 Page 1 of 9  
UHP-28.2/12-D48  
Isolated, 12 Amp Half Brick, 48VIN/28.2VOUT DC/DC Converters  
PERFORMANCE SPECIFICATIONS AND ORDERING GUIDE  
Output  
Input  
Package  
R/N (mVp-p)  
Regulation  
Efficiency  
VOUT  
(Volts)  
IOUT  
(Amps)  
VIN Nom.  
(Volts)  
Range  
(Volts)  
IIN  
(Case/  
Model  
(mA/A)  
Min.  
89.ꢀ5  
Typ.  
Pinout)  
Typ.  
Max.  
Line  
Load  
0.15  
UHP-28.2/12-D48  
28.2  
12  
100  
160  
0.0ꢀ5  
48  
36-7ꢀ  
7ꢀ/7.06  
91.ꢀ5  
C66, P17  
Typical at TA = +25°C under nominal line voltage and full-load conditions, unless noted.  
Ripple/Noise (R/N) is measured over a 20MHz bandwidth and input filter.  
Regulation is tested no load to 100% load.  
Nominal line voltage, no-load/full-load conditions.  
PART NUMBER STRUCTURE  
UHP - 28.2 / 12 D48 N B  
-
Unipolar High-Power  
Baseplate:  
Blank = not installed, standard  
B = Installed, optional  
Nominal Output Voltage:  
28.2 Volts  
On/Off control Polarity  
P = Positive, optional  
N = Negative, standard  
Maximum Output Current:  
12 Amps  
Note: Some model number combinations  
may not be available. Please contact  
Murata Power Solutions.  
Input Voltage Range:  
D48 = 36-75 Volts (48V nominal)  
ꢀ).054  
ꢀ/54054  
/54054  
2%452.  
3%#/.$!29  
37)4#(  
#/.42/,  
02)-!29  
37)4#(  
#/.42/,  
()##50  
/54054 /60  
n).054  
#!3%  
ꢀ3%.3%  
n3%.3%  
07-  
#/.42/,,%2  
/04/  
)3/,!4)/.  
2%&%2%.#% ꢂ  
%22/2 !-0  
56 #/-0!2!4/2  
4(%2-!,  
3(54$/7.  
42)-  
/.ꢁ/&&  
#/.42/,ꢁ  
Typical topology is shown.  
Figure 1. Simplified Schematic  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
UHP_28.2/12_D48.B02 Page 2 of 9  
UHP-28.2/12-D48  
Isolated, 12 Amp Half Brick, 48VIN/28.2VOUT DC/DC Converters  
Performance/Functional Specifications  
Typical @ TA = +25°C under nominal line voltage, full-load conditions, unless noted.  
Dynamic Characteristics  
(1)  
Dynamic Load Response (50-75-50%step) 100µsec to 1% of final value  
Input  
Load Step Peak Deviation  
600mV  
Input Voltage Range  
Start-Up Threshold  
See Ordering Guide  
34 Volts  
Start-Up Time  
(VIN on to VOUT regulated or On/Off to VOUT)  
360msec for VOUT = nominal  
Switching Frequency  
320kHz  
Undervoltage Shutdown  
32 Volts  
Environmental  
Voltage Transients (100msec, no damage) +100 Volts max.  
(7)  
(4)  
Calculated MTBF  
>3,000,000 Hours  
Overvoltage Shutdown  
None  
(2)  
Baseplate Temperature Range  
–40 to +110°C max.  
Reflected (Back) Ripple Current  
50mAp-p  
(3) (13)  
(See derating curve)  
Input Current:  
Storage Temperature Range  
–55 to +125°C  
Full Load Conditions  
Inrush Transient  
Output Short Circuit  
No Load  
Low Line (VIN = VMIN)  
Standby Mode  
See Ordering Guide  
1A2sec  
200mA  
75mA  
9.37 Amps  
10mA max.  
(13)  
Thermal Protection/Shutdown  
+115°C  
Relative Humidity  
To 85% / +85°C, non-condensing  
No audible output in normal  
Acoustic Output 20Hz to 20kHz  
(1ꢀ)  
office environments  
(Off, UV, OT, OC shutdown)  
Physical  
Internal Input Filter  
Pi-type  
Outline Dimensions  
Baseplate Material  
Pin Material  
Weight  
See Mechanical Specifications  
Aluminum  
Recommended External Fuse  
Reverse Polarity Protection  
(ꢀ)  
18 Amps slow blow  
See fuse information  
Copper alloy  
Remote On/Off Control:  
3.9 ounces (110 grams)  
Positive Logic ("P" model suffix)  
Negative Logic ("N" model suffix)  
Current  
ON = open pin or +2.8V to +12V max.  
OFF = ground pin to +0.8V max.  
ON = ground pin to +0.8V max.  
OFF = open pin or +2.8V to +12V max.  
1mA  
Electromagnetic Interference  
Conducted and radiated  
FCC part 15, class B, EN55022  
(external filter required)  
Safety  
UL/cUL 60950-1 CSA-C22.2 No.234  
IEC/EN 60950 UL1012  
Surge, Shock, Vibration  
Flammability  
ETSI 300-019-2-4  
ULV94-0  
Output  
Total Output Power  
342 Watts max.  
See Ordering Guide  
1 % of Vnominal  
Voltage Output Range  
Voltage Output Accuracy  
Absolute Maximum Ratings  
(14)  
Input Voltage  
Continuous  
Transient (100 msec max.)  
Overvoltage Protection  
Method  
+125% of VOUT nominal  
Magnetic feedback  
to +7ꢀV  
to +100V  
(12)  
Voltage Adjustment Range  
Temperature Coefficient  
Minimum Loading  
+25.4V min. to +31V max.  
0.02% of VOUT range per °C  
No minimum load  
On/Off Control  
–0.3 V min to +12V max.  
See Fuse section (11)  
VOUT +2ꢀ5 max.  
Input Reverse Polarity Protection  
Output Overvoltage  
Output Current (7)  
Remote Sense Compensation  
Ripple/Noise (20 MHz bandwidth)  
Line/Load Regulation  
Efficiency  
+1% max.  
Current-limited. Devices can  
withstand sustained short circuit  
without damage.  
(8)  
See Ordering Guide  
(10)  
See Ordering Guide and note  
See Ordering Guide  
Storage Temperature  
–ꢀꢀ to +12ꢀ°C  
+280°C  
Maximum Capacitive Loading (Resistive) 3300µF (Low ESR <0.02W max.)  
Lead Temperature (soldering 10 sec. max.)  
Isolation Voltage:  
Input to Output  
Input to Baseplate  
Baseplate to Output  
These are stress ratings. Exposure of devices to any of these conditions may adversely  
affect long-term reliability. Proper operation under conditions other than those listed in the Perfor-  
mance/Functional Specifications Table is not implied, nor recommended.  
2250Vdc min.  
1500Vdc min.  
750Vdc min.  
Isolation Resistance  
100MW  
Isolation Capacitance  
2000 pF  
Isolation Safety Rating  
Basic insulation  
Performance/Functional Specification Notes:  
Current Limit Inception (98% of VOUT)  
16 Amps at cold start  
15 Amps after warmup  
(1) The UHP-28.2/12-D48 is tested and specified with external 1 || 10 µF ceramic/tantalum  
output capacitors and a 22µF external input capacitor. All capacitors are low ESR types. These  
capacitors are necessary to accommodate our test equipment and may not be required to  
achieve specified performance in your applications. All models are stable and regulate within  
spec under no-load conditions.  
General conditions for Specifications are +25°C, VIN = nominal, VOUT = nominal, full load.  
(2) Input Ripple Current is tested and specified over a 5Hz to 20MHz bandwidth. Input filtering is  
CIN = 33µF tantalum, CBUS = 220µF electrolytic, LBUS = 12µH.  
(6)  
Short Circuit  
Protection Method  
Short Circuit Current  
Short Circuit Duration  
Current limiting with hiccup autorestart  
TBD  
Continuous, output shorted to ground  
(no damage)  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
UHP_28.2/12_D48.B02 Page 3 of 9  
UHP-28.2/12-D48  
Isolated, 12 Amp Half Brick, 48VIN/28.2VOUT DC/DC Converters  
Performance/Functional Specification Notes:  
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage.  
At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current  
outputs if the total RMS current over time does not exceed the Derating curve.  
TECHNICAL NOTES  
Input Fusing  
(4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1,  
Case 3, ground fixed conditions, TCASE = +40°C, full output load, natural air convection.  
(5) The On/Off Control may be driven with external logic or by applying appropriate external voltages  
which are referenced to Input Common. The On/Off Control Input should use either an open col-  
lector/open drain transistor or logic gate which does not exceed +12V.  
(6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the  
selected setting. Remove overload for recovery.  
(7) Input overvoltage shutdown is explicitly not included to improve system reliability in datacom and  
telecom applications. These requirements attempt continued operation despite significant input  
overvoltage.  
Certain applications and/or safety agencies may require the installation of  
fuses at the inputs of power conversion components. Fuses should also be  
used if the possibility of sustained, non-current-limited, input-voltage polarity  
reversals exists. For DATEL UHP Series DC/DC Converters, we recommend the  
use of slow-blow type fuses, installed in the ungrounded input supply line,  
with values no greater than the following.  
Output  
Fuse Value  
(8) Output noise may be further reduced by adding an external filter. See I/O Filtering and Noise  
Reduction. Use only as much external output filtering as needed and no more. Larger caps  
(especially low-ESR ceramic types) may degrade dynamic performance or cause possible failed  
starts. Thoroughly test your application with all components installed.  
(9) Models are fully operational and meet published specifications, including “cold start” at –40°C.  
(10) Regulation specifications describe the deviation as the line input voltage or output load current is  
varied from a nominal midpoint value to either extreme.  
(11) If the input voltage is reversed, a normally back-biased bulk substrate diode will become forward  
biased and draw current. An external fuse is recommended to avoid damage from reverse input  
current.  
28 VOUT  
18 Amp  
All relevant national and international safety standards and regulations must  
be observed by the installer. For system safety agency approvals, the convert-  
ers must be installed in compliance with the requirements of the end-use  
safety standard, i.e. IEC/EN/UL60950.  
Input Undervoltage Shutdown and Start-Up Threshold  
(12) Do not exceed maximum power specifications when adjusting the output trim.  
Under normal start-up conditions, devices will not begin to regulate properly  
until the ramping-up input voltage exceeds the Start-Up Threshold Voltage.  
Once operating, devices will not turn off until the input voltage drops below  
the Undervoltage Shutdown limit. Subsequent re-start will not occur until the  
input is brought back up to the Start-Up Threshold. This built in hysteresis pre-  
vents any unstable on/off situations from occurring at a single input voltage.  
(13) Note that the converter may operate derated up to +110°C with the baseplate installed. However,  
thermal self-protection occurs near +115°C and there is a thermal gradient from the hotspot to  
the baseplate. Therefore, +110°C is recommended to avoid thermal shutdown.  
(14) If the output exceeds the Overvoltage specification, the output will shut down in latching mode.  
To restore normal operation, either power down the unit or cycle the On/Off control.  
(15) Acoustic output is measured by subjecting the converter to both 0-100-0% and 50-100-50%  
step loads at load pulse frequencies of 100Hz, 300Hz and 1kHz.  
Start-Up Time  
The VIN to VOUT Start-Up Time is the interval of time between the point at which  
the ramping input voltage crosses the Start-Up Threshold and the fully loaded  
output voltage enters and remains within 90% of VOUT . Actual measured times  
will vary with input source impedance, external input capacitance, and the  
slew rate and final value of the input voltage as it appears at the converter.  
The UHP Series implements a soft start circuit that limits the duty cycle of its  
PWM controller at power up, thereby limiting the input inrush current.  
The On/Off Control to VOUT start-up time assumes the converter has its  
nominal input voltage applied but is turned off via the On/Off Control pin. The  
specification defines the interval between the point at which the converter is  
turned on (released) and the fully loaded output voltage enters and remains  
within its specified accuracy band.  
Similar to the VIN to VOUT start-up, the On/Off Control to VOUT start-up time is  
also governed by the internal soft start circuitry and external load capacitance.  
The difference in start up time from VIN to VOUT and from On/Off Control to VOUT  
is therefore insignificant.  
Input Overvoltage Shutdown  
The UHP Series does not feature input overvoltage shutdown. The converters  
do withstand and fully operate during input transients to 100V for 100msec  
without interruption; consequently, this function has been disabled.  
Input Source Impedance  
The input of UHP converters must be driven from a low ac-impedance source.  
The DC/DC's performance and stability can be compromised by the use of  
highly inductive source impedances. The input circuit shown in Figure 2 is a  
practical solution that can be used to minimize the effects of inductance in the  
input traces. For optimum performance, components should be mounted as  
close as possible to the DC/DC converter.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
UHP_28.2/12_D48.B02 Page 4 of 9  
UHP-28.2/12-D48  
Isolated, 12 Amp Half Brick, 48VIN/28.2VOUT DC/DC Converters  
I/O Filtering, Input Ripple Current, and Output Noise  
All models in the UHP Series are tested/specified for input reflected ripple cur-  
rent and output noise using the specified external input/output components/  
circuits and layout as shown in the following two figures.  
6
COPPER STRIP  
+SENSE  
5
+OUTPUT  
External input capacitors (CIN in Figure 2) serve primarily as energy-storage  
elements, minimizing line voltage variations caused by transient IR drops in  
conductors from backplane to the DC/DC. Input caps should be selected for  
bulk capacitance (at appropriate frequencies), low ESR, and high rms-ripple-  
current ratings. The switching nature of DC/DC converters requires that dc  
voltage sources have low ac impedance as highly inductive source imped-  
ance can affect system stability. In Figure 2, CBUS and L simulate a typical dc  
voltage bus. Your specific system configuration may necessitate additional  
considerations.  
RLOAD  
SCOPE  
C1  
C2  
9
8
–OUTPUT  
–SENSE  
COPPER STRIP  
C1 = 0.1µF CERAMIC  
C2 = 10µF TANTALUM  
LOAD 2-3 INCHES (51-76mm) FROM MODULE  
Figure 3. Measuring Output Ripple/Noise (PARD)  
TO  
CURRENT  
PROBE  
OSCILLOSCOPE  
4
1
+INPUT  
–INPUT  
Minimum Output Loading Requirements  
UHP converters employ a synchronous-rectifier design topology and all  
models regulate within spec and are stable under no-load to full load condi-  
tions. Operation under no-load conditions however might slightly increase the  
output ripple and noise.  
L
BUS  
+
V
IN  
CBUS  
CIN  
C
IN = 33µF, ESR < 700m@ 100kHz  
BUS = 220µF, ESR < 100m@ 100kHz  
Thermal Shutdown  
C
L
BUS = 12µH  
The UHP converters are equipped with thermal-shutdown circuitry. If envi-  
ronmental conditions cause the temperature of the DC/DC converter to rise  
above the designed operating temperature, a precision temperature sensor  
will power down the unit. When the internal temperature decreases below the  
threshold of the temperature sensor, the unit will self start. See Performance/  
Functional Specifications.  
Figure 2. Measuring Input Ripple Current  
In critical applications, output ripple/noise (also referred to as periodic and  
random deviations or PARD) may be reduced below specified limits using  
filtering techniques, the simplest of which is the installation of additional  
external output capacitors. They function as true filter elements and should be  
selected for bulk capacitance, low ESR and appropriate frequency response.  
All external capacitors should have appropriate voltage ratings and be located  
as close to the converter as possible. Temperature variations for all relevant  
parameters should also be taken carefully into consideration.  
Output Overvoltage Protection  
The UHP output voltage is monitored for an overvoltage condition using a  
comparator. The signal is optically coupled to the primary side and if the  
output voltage rises to a level which could be damaging to the load, the sens-  
ing circuitry will power down the PWM controller causing the output voltage to  
decrease. Following a time-out period the PWM will restart, causing the output  
voltage to ramp to its appropriate value. If the fault condition persists, and the  
output voltage again climbs to excessive levels, the overvoltage circuitry will  
initiate another shutdown cycle. This on/off cycling is referred to as "hiccup"  
mode.  
The most effective combination of external I/O capacitors will be a function  
of line voltage and source impedance, as well as particular load and layout  
conditions. Our Applications Engineers can recommend potential solutions and  
discuss the possibility of our modifying a given device's internal filtering to  
meet your specific requirements. Contact our Applications Engineering Group  
for additional details.  
Current Limiting  
As soon as the output current increases to approximately 125% of its rated  
value, the DC/DC converter will go into a current-limiting mode. In this condi-  
tion, the output voltage will decrease proportionately with increases in output  
current, thereby maintaining somewhat constant power dissipation. This is  
commonly referred to as power limiting. Current limit inception is defined as  
the point at which the full-power output voltage falls below the specified toler-  
ance. See Performance/Functional Specifications. If the load current, being  
drawn from the converter, is significant enough, the unit will go into a short  
circuit condition as described below.  
In Figure 3, the two copper strips simulate real-world PCB impedances  
between the power supply and its load. In order to minimize measurement  
errors, scope measurements should be made using BNC connectors, or  
the probe ground should be as short as possible (i.e. less than ½ inch) and  
soldered directly to the fixture.  
Floating Outputs  
Since these are isolated DC/DC converters, their outputs are "floating" with  
respect to their input. Designers will normally use the –Output (pin 9) as the  
ground/return of the load circuit. You can however, use the +Output (pin 5) as  
ground/return to effectively reverse the output polarity.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
UHP_28.2/12_D48.B02 Page 5 of 9  
UHP-28.2/12-D48  
Isolated, 12 Amp Half Brick, 48VIN/28.2VOUT DC/DC Converters  
Short Circuit Condition  
overvoltage protection circuitry to activate (see Performance Specifications for  
overvoltage limits). Power derating is based on maximum output current and  
voltage at the converter's output pins. Use of trim and sense functions can  
cause output voltages to increase, thereby increasing output power beyond  
the conveter's specified rating, or cause output voltages to climb into the  
output overvoltage region. Therefore, the designer must ensure:  
When a converter is in current-limit mode, the output voltage will drop as  
the output current demand increases. If the output voltage drops too low, the  
magnetically coupled voltage used to develop primary side voltages will also  
drop, thereby shutting down the PWM controller. Following a time-out period,  
the PWM will restart causing the output voltage to begin ramping to their  
appropriate value. If the short-circuit condition persists, another shutdown  
cycle will be initiated. This on/off cycling is referred to as "hiccup" mode. The  
hiccup cycling reduces the average output current, thereby preventing internal  
temperatures from rising to excessive levels. The UHP Series is capable of  
enduring an indefinite short circuit output condition.  
(VOUT at pins) x (IOUT ) =< rated output power  
On/Off Control  
The primary-side, Remote On/Off Control function (pin 3) can be specified to  
operate with either positive or negative polarity. Positive-polarity devices ("P"  
suffix) are enabled when pin 3 is left open or is pulled high. Positive-polarity  
devices are disabled when pin 3 is pulled low (0-0.8V with respect to –Input).  
Negative-polarity devices are off when pin 3 is high/open and on when pin 3  
is pulled low or grounded. See Figure 5.  
Features and Options  
Remote Sense  
Note: The Sense and VOUT lines are internally connected through resistors  
(=<10W). Nevertheless, if the sense function is not used for remote regulation  
the user should connect the +Sense to +VOUT and –Sense to –VOUT at the DC/  
DC converter pins.  
EQUIVALENT CIRCUIT FOR  
POSITIVE AND NEGATIVE  
LOGIC MODELS  
+INPUT  
4
3
+
UHP Series converters employ a sense feature to provide point of use regula-  
tion, thereby overcoming moderate IR drops in pcb conductors or cabling.  
The remote sense lines carry very little current and therefore require minimal  
cross-sectional-area conductors. The sense lines, which are capacitively  
coupled to their respective output lines, are used by the feedback control-loop  
to regulate the output. As such, they are not low impedance points and must  
be treated with care in layouts and cabling. Sense lines on a pcb should be  
run adjacent to dc signals, preferably ground. In cables and discrete wiring  
applications, twisted pair or other techniques should be implemented.  
CONTROL  
ON/OFF  
CONTROL  
REF  
1
–INPUT  
Figure 5. Driving the On/Off Control Pin  
Contact and PCB resistance  
losses due to IR drops  
5
Dynamic control of the remote on/off function is best accomplished with  
a mechanical relay or an open-collector/open-drain drive circuit (optically  
isolated if appropriate). The drive circuit should be able to sink appropri-  
ate current (see Performance Specifications) when activated and withstand  
appropriate voltage when deactivated.  
1
+OUTPUT  
–INPUT  
IOUT  
6
+SENSE  
Sense Current  
3
ON/OFF  
CONTROL  
7
8
TRIM  
–SENSE  
LOAD  
Sense Return  
IOUT Return  
Trimming Output Voltage  
UHP converters have a trim capability (pin 7) that allows users to adjust the  
output voltage within the specified range. Adjustments to the output voltages  
can be accomplished via a trim pot (Figure 6) or a single fixed resistor, shown  
in Figures 7 and 8. A single fixed resistor can increase or decrease the output  
voltage depending on its connection. The resistor should be located close to  
the converter and have a TCR less than 100ppm/°C to minimize sensitivity to  
temperature changes. If the trim function is not used, leave the trim pin floating.  
4
9
+INPUT  
–OUTPUT  
Contact and PCB resistance  
losses due to IR drops  
Figure 4. Remote Sense Circuit Configuration  
A single resistor connected from the Trim (pin 7) to the +Sense (pin 6), will  
increase the output voltage (Figure 8). A resistor connected from the Trim (pin  
9) to the –Sense (pin 8), will decrease the output voltage (Figure 9).  
UHP Series converters will compensate for drops between the output voltage  
at the DC/DC and the sense voltage at the DC/DC provided that:  
Trim adjustments greater than the specified range can have an adverse affect  
on the converter's performance and are not recommended. Excessive voltage  
differences between VOUT and Sense, in conjunction with trim adjustment of  
the output voltage, can cause the overvoltage protection circuitry to activate  
(see Performance Specifications for overvoltage limits). Power derating is  
based on maximum output current and voltage at the converter's output  
[VOUT (+) –VOUT (–)] –[Sense(+) –Sense (–)] =< 10% VOUT  
Output overvoltage protection is monitored at the output voltage pin, not the  
Sense pin. Therefore, excessive voltage differences between VOUT and Sense  
in conjunction with trim adjustment of the output voltage can cause the  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
UHP_28.2/12_D48.B02 Page 6 of 9  
UHP-28.2/12-D48  
Isolated, 12 Amp Half Brick, 48VIN/28.2VOUT DC/DC Converters  
pins. Use of trim and sense functions can cause output voltages to increase,  
thereby increasing output power beyond the converter's specified rating or  
cause output voltages to climb into the output overvoltage region. Therefore:  
TYPICAL PERFORMANCE CURVES  
5(0ꢀꢁꢂꢃꢁꢄꢅꢁꢀ$ꢆꢂ  
%FFICIENCY VSꢃ ,INE 6OLTAGE AND ,OAD #URRENT   ꢇꢁꢈ—#  
(VOUT at pins) x (IOUT ) =< rated output power  
ꢀꢁ  
ꢀꢂ  
ꢀꢃ  
ꢄꢄ  
ꢄ/54054  
n).054  
ꢄ3%.3%  
ꢀꢁK7  
6
). ꢁ ꢈꢄ6  
42)-  
n3%.3%  
ꢂꢃꢀꢁ  
,/!$  
ꢄꢅ  
ꢄꢁ  
ꢄꢂ  
ꢄꢃ  
ꢆꢄ  
452.3  
/.ꢅ/&&  
#/.42/,  
6
). ꢁ ꢂꢃ6  
6
). ꢁ ꢄꢅ6  
ꢄ).054  
n/54054  
6
). ꢁ ꢆꢇ6  
Figure 6.Trim Connections Using A Trim Pot  
ꢇꢈꢂ  
ꢂꢈꢁ  
ꢉꢈꢅ  
ꢁꢈꢄ  
ꢆꢈꢂ  
ꢄꢈꢁ  
ꢀꢈꢅ  
ꢇꢃꢈꢄ  
ꢇꢂ  
,OAD #URRENT ꢉ!MPSꢊ  
5
1
+OUTPUT  
–INPUT  
6
7
8
9
+SENSE  
TRIM  
UHP Converter Series Mounting  
LOAD  
RTRIM UP  
3
4
ON/OFF  
CONTROL  
The UHP series include a multilayer planar-magnetic Printed Circuit Board  
(PCB), high-current Input/Output pins, four removable brass mounting standoffs  
and an optional machined aluminum baseplate. See Mechanical Specifications.  
–SENSE  
–OUTPUT  
+INPUT  
A user’s installation will normally have a host PCB to solder to the converter’s  
I/O pins. To avoid placing the full mechanical mounting load on the I/O pins,  
we recommend that the user’s PCB also includes bolts through the PCB to  
assemble to the standoffs. Note the #M3 metric threading of the standoffs.  
Avoid excessive torque assembling the bolts to the standoffs. Use lock wash-  
ers or locking compound to avoid loosening of the mounting bolts.  
Figure 7.Trim Connections To Increase Output Voltages Using Fixed Resistors  
5
1
+OUTPUT  
–INPUT  
The standoffs include machined shoulders so that mechanical force is not  
placed against the converter’s power components. To avoid long-term oxida-  
tion of the host PCB, be sure to accommodate the relatively high temperatures  
of the power components adjacent to the user’s host PCB. Normally, a planar  
grounded area of copper etch on the PCB surface will be sufficient to spread  
the heat, reduce electrical noise and avoid hotspots. A relief dimension on the  
standoffs floats the power components 0.02 inches minimum from the user’s  
host PCB.  
6
+SENSE  
7
TRIM  
–SENSE  
LOAD  
RTRIM DOWN  
3
4
ON/OFF  
CONTROL  
8
9
+INPUT  
–OUTPUT  
The baseplate is in thermal contact with the power components and practi-  
cally all the converter’s internal heat dissipation is conducted away via the  
baseplate. Users typically have two choices to remove this thermal load—  
either an extruded aluminum finned heat sink or a thermal mounting surface  
such as a chassis wall. The heatsink depends on ambient temperature, airflow  
and total power extracted from the converter, depending on the input voltage  
and converter efficiency. Do not attempt to conduct all baseplate heat solely  
through the standoffs. Use either a thermal pad or thermal mounting com-  
pound (“thermal grease”) when attaching the baseplate to its mounting sur-  
face. Keep baseplate temperature below +110°C. Study the Derating Curve.  
Figure 8.Trim Connections To Decrease Output Voltages Using Fixed Resistors  
Trim Equations  
1036  
100  
RTUP (kW) = 10 (  
) + 936  
RTDOWN (kW) = 10 (  
) – 2  
D5  
D5  
where D5 is the desired change of the output voltage in percent relative to VNOMINAL. Or,  
VOUT – VNOM  
D5 =  
x 100  
VNOM  
For chassis wall mounting, the user must consider the tolerance buildup—the  
host PCB, mounting standoffs, thermal pad and placement of the chassis wall.  
Measure carefully to avoid unwanted mechanical stresses.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
UHP_28.2/12_D48.B02 Page 7 of 9  
UHP-28.2/12-D48  
Isolated, 12 Amp Half Brick, 48VIN/28.2VOUT DC/DC Converters  
MECHANICAL SPECIFICATIONS  
Case C66  
2.30  
(58.4)  
A
1.900  
(48.3)  
A
I/O CONNECTIONS  
Pin  
1
Function P17  
–Input  
2
Case  
3
On/Off Control  
+Input  
4
5
+Output  
+Sense  
Trim  
BASEPLATE  
6
2.40  
(61.0)  
2.000  
(50.8)  
7
8
–Sense  
–Output  
9
#M3 x 0.50  
THREAD THROUGH  
Connect each sense input to its respective Vout  
if sense is not connected at a remote load.  
0.53 MAX.  
(13.5)  
0.49 (12.5)  
Without Baseplate  
0.24Ø (  
TYP. 4  
6.1) Br  
PL  
ass Sta  
ndoff  
PINS 1-4, 6-8:  
0.040Ø 0.001  
(1.016 0.025)  
0.15 MIN.  
(3.8)  
PINS 5 & 9:  
0.080 0.001 (2.03 0.025)  
Dimensions are in inches (mm shown for ref. only).  
9
8
Third Angle Projection  
1
2
1.40  
(35.56)  
7
6
Tolerances (unless otherwise specified):  
.XX ꢀ.ꢀ0 (ꢀ.ꢁ)  
.XXX ꢀ.ꢀꢂꢀ (ꢀ.0ꢁ)  
Angles 02  
3
4
5
0.60  
(15.24)  
Components are shown for reference only.  
0.30  
(7.62)  
1.900  
(48.3)  
A
BOTTOM VIEW  
DIMENSIONS ARE IN INCHES (MM)  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
UHP_28.2/12_D48.B02 Page 8 of 9  
UHP-28.2/12-D48  
Isolated, 12 Amp Half Brick, 48VIN/28.2VOUT DC/DC Converters  
Thermal Management  
“No airflow” applications are normally those with the converter bolted to a  
chassis wall or other large heat-conducting surface. For such wall installa-  
tions, there is no explicit airflow specification and the converter may be used  
with zero airflow as long as the baseplate does not exceed +110°C.  
“Zero Airflow” Passive Cooling Enclosure Installations  
The UHP-28.2/12-D48 converter will deliver its full rated power as long as  
the user maintains the baseplate at +80°C or less. Usable power is available  
derated up to +110°C baseplate temperature. Please see the “baseplate”  
Derating curve below. This curve is different from standard Derating curves  
because no airflow is indicated. This is a reflection of the requirement to  
only limit the baseplate temperature since the majority of the heat flows out  
through the baseplate. Some heat is removed via airflow convection over the  
converter.  
Consider using thermal pads or compound (“thermal grease”) to lower the  
thermal resistance between the baseplate and the chassis wall. Do not rely  
only on the baseplate mounting screws to transfer heat. Also, since a housing  
wall is not an infinite heat sink, most real-world enclosure installations are  
improved by moderate forced airflow. This airflow cools both the mounting  
surface and the converter itself by convection. Larger area and/or a thicker  
mounting surface material will conduct more heat away and allow higher  
output power.  
UHP-28.2/12-D48N Maximum Baseplate Temperature vs. Output Power (6). ꢀ ꢁꢂ6ꢃ  
Because of the high efficiency of the converter, the mounting surface only  
carries away the internal dissipation of the converter, not the entire power  
output. For computation purposes, the enclosure surface may use the follow-  
ing dissipation equations:  
ꢃꢅꢁ  
ꢃꢄꢁ  
ꢃꢀꢁ  
ꢃꢁꢁ  
ꢀꢇꢁ  
ꢀꢅꢁ  
ꢀꢄꢁ  
ꢀꢀꢁ  
P(diss) = PowerIn – PowerOut and,  
PowerOut / PowerIn x 100 = Efficiency (in %) and,  
P(diss) = PowerIn (1 – Efficiency/100)  
where “P(diss)” is the internal power dissipation of the converter.  
Efficiency is given in percent. For example, with 92% efficiency at VIN = 48V  
and 300 Watts out, P(diss) is 24 Watts.  
Heat Sink Usage  
The UHP-28.2/12-D48 converter is primarily intended for baseplate and  
enclosure mount installations. However, if you prefer to attach the converter’s  
baseplate to an extruded aluminum heatsink in a traditional fan-forced airflow  
installation, the user must carefully compute the thermal resistance of the  
heat sink versus the power dissipation versus the ambient temperature and  
airflow over the heatsink. As with the passive mounting surface installations,  
the baseplate temperature should never exceed +110°C.  
ꢉꢉꢁ  
ꢀꢁ ꢀꢂ ꢃꢁ ꢃꢂ ꢄꢁ ꢄꢂ ꢂꢁ ꢂꢂ ꢅꢁ ꢅꢂ ꢆꢁ ꢆꢂ ꢇꢁ ꢇꢂ ꢈꢁ ꢈꢂ ꢉꢁꢁ ꢉꢁꢂ  
Baseplate Temperature ( C)  
°
Figure 9. Maximum Baseplate Temperature vs. Output Power  
USA:  
Canada: Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com  
UK: Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com  
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356  
www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED  
07/10/08  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com  
Germany: München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com  
Japan: Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com  
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com  
Website: www.murata-ps.jp  
China:  
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com  
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com  
notice.  
© 2008 Murata Power Solutions, Inc.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
UHP_28.2/12_D48.B02 Page 9 of 9  

相关型号:

UHP-28.2/12-D48PB

DC-DC Regulated Power Supply Module, 1 Output, 342W, Hybrid, HALF BRICK PACKAGE-9
MURATA

UHP-3-3-30-D48

Single Output UHP Models
ETC

UHP-3.3/45-D48N

DC-DC Regulated Power Supply Module, 1 Output, Hybrid,
MURATA

UHP-3.3/45-D48S

DC-DC Regulated Power Supply Module, 1 Output, Hybrid,
MURATA

UHP-3.3/45-D48SL1

DC-DC Regulated Power Supply Module, 1 Output, Hybrid,
MURATA

UHP-400

Quad Peripheral Driver
ETC

UHP-400-1

Quad Peripheral Driver
ETC

UHP-402

Quad Peripheral Driver
ETC

UHP-402-1

Quad Peripheral Driver
ETC

UHP-403

Quad Peripheral Driver
ETC

UHP-403-1

Quad Peripheral Driver
ETC

UHP-406

Quad Peripheral Driver
ETC