ULQ Models  
s
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
To Be Discontinued*  
Typical units  
Features  
For applications requiring improved electrical and thermal perfomance at reduced cost DATEL's  
new ULQ Series "Quarter-Brick" DC-DC Converters suit perfectly. They measure just 1.45 x 2.30 x  
0.35 inches (36.8 x 58.4 x 8.9mm) and fit the industry-standard footprint. You can also "pick-and-  
place" the ULQ-SMT version optimizing your automated SMT process.  
From an 18-36V or 36-75V input, ULQ's deliver outputs of 1.2, 1.5, 1.8, or 2V fully rated at 15 or  
25A, 2.5 or 3.3V at 15 or 20A, 5V at 15A and 12V at 8-10A. They  
employ an interleaved, synchronous-rectifier topology that exploits 100% of their duty cycle. They  
simultaneously achieve ultra-high efficiency (to 91%), tight line/load regulation ( 0.125/0.25%), low  
noise (25-70mVp-p), and quick step response (200µsec).  
A state of the art, single-board, open-frame design with reduced component count, high  
efficiency, low-on-resistance FET's, and planar magnetics embedded in heavy-copper pc boards all  
contribute to impressive thermal derating.  
Standard quarter-brick package/pinout  
in through-hole or SMT version  
Low cost; Low profile, 0.35" (8.9mm)  
24V and 48V nominal inputs  
Output current: 8 to 25 Amps  
Output voltages: 1.2/1.5/1.8/2/2.5/3.3/5/12V  
Interleaved synchronous-rectifier topology  
·
·
Ultra high efficiency  
No output reverse conduction  
Outstanding thermal performance  
On/off control, trim & sense functions  
Fully isolated, 2250Vdc (BASIC)  
Output overvoltage protection  
Fully I/O protected; Thermal shutdown  
UL/EN/IEC60950 safety approvals  
Qual/HALT/EMI tested  
The ULQ's feature set includes high isolation (2250Vdc), input pi filters, input undervoltage shut-  
down, output overvoltage protection, current limiting, short-circuit protection and thermal shutdown.  
The standard footprint carries on/off control (positive or negative logic), output trim (+10/–20%) and  
output sense functions.  
All ULQ quarter-bricks are designed to meet the BASIC-insulation requirements of UL/EN/  
IEC60950 and they will carry the CE mark. Safety certifications, EMC compliance testing and qualifi-  
cation testing (including HALT) are currently in progress. Contact DATEL for latest updates.  
+SENSE  
(7)  
+VOUT  
(8)  
+VIN  
(1)  
SWITCH  
CONTROL  
–VOUT  
(4)  
–VIN  
(3)  
–SENSE  
(5)  
PWM  
CONTROLLER  
OPTO  
ISOLATION  
REFERENCE &  
ERROR AMP  
VOUT  
TRIM  
(6)  
INPUT UNDERVOLTAGE, INPUT  
OVERVOLTAGE, AND OUTPUT  
OVERVOLTAGE COMPARATORS  
* Can be ordered with positive (standard) or negative (optional) polarity.  
REMOTE  
ON/OFF  
CONTROL*  
(2)  
Figure 1. Simplified Schematic  
Typical topology is shown.  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 1 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
Performance Specifications and Ordering Guide ➀  
ORDERING GUIDE  
Output  
R/N (mVp-p) ➁  
Input  
Package  
(Case,  
Efficiency  
Regulation (Max.)  
Root Model ➄  
Vout  
Vin Nom. Range  
Iout ➁  
IIN ➃  
Pinout)  
(Volts)  
(Volts) (Volts) (mA/A)  
35/0.5  
50/1.8 85.5%  
30/0.9 85%  
(Amps)  
Typ.  
25  
50  
45  
25  
50  
70  
25  
50  
70  
35  
45  
50  
45  
50  
50  
95  
90  
45  
50  
45  
50  
50  
95  
90  
Max.  
50  
Line  
Min.  
87%  
Typ.  
89%  
Load ➂  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.4%  
ULQ-1.5/15-D48N-C  
ULQ-1.5/25-D24P-C  
ULQ-1.5/25-D48N-C  
ULQ-1.8/15-D48N-C  
ULQ-1.8/25-D24P-C  
ULQ-1.8/25-D48N-C  
ULQ-2/15-D48N-C  
ULQ-2/25-D24P-C  
ULQ-2/25-D48N-C  
ULQ-2.5/15-D48N-C  
ULQ-3.3/15-D48NM-C  
ULQ-3.3/20-D24PM-C  
ULQ-3.3/20-D48NM-C  
ULQ-5/15-D24PM-C  
ULQ-5/15-D48NM-C  
ULQ-12/8-D24PM-C  
ULQ-12/10-D48NM-C  
ULQ-3.3/15-D48N-C  
ULQ-3.3/20-D24P-C  
ULQ-3.3/20-D48N-C  
ULQ-5/15-D24P-C  
ULQ-5/15-D48N-C  
ULQ-12/8-D24P-C  
ULQ-12/10-D48N-C  
1.5  
1.5  
1.5  
1.8  
1.8  
1.8  
2
15  
25  
25  
15  
25  
25  
15  
25  
25  
15  
15  
20  
20  
15  
15  
8
0.125%  
0.125%  
0.125%  
0.125%  
0.125%  
0.25%  
0.125%  
0.125%  
0.25%  
0.125%  
0.125%  
0.125%  
0.125%  
0.25%  
0.1%  
48  
24  
48  
48  
24  
48  
48  
24  
48  
48  
48  
24  
48  
24  
48  
24  
48  
48  
24  
48  
24  
48  
24  
48  
36-75  
18-36  
36-75  
36-75  
18-36  
36-75  
36-75  
18-36  
36-75  
36-75  
36-75  
18-36  
36-75  
18-36  
36-75  
18-36  
36-75  
36-75  
18-36  
36-75  
18-36  
36-75  
18-36  
36-75  
C37, P32  
C37, P32  
100  
75  
87.5%  
87%  
C37, P32  
50  
35/0.6 87.5%  
90/2.2 85.5%  
45/1.1 85.5%  
89%  
C37, P32  
100  
100  
50  
87.5%  
87.5%  
89%  
C37, P32  
C37, P32  
45/0.6  
50/2.4  
50/1.2  
45/0.9  
87%  
86%  
86%  
88%  
C37, P32  
2
100  
100  
55  
88%  
C37, P32  
2
88%  
C37, P32  
2.5  
3.3  
3.3  
3.3  
5
89.5%  
90.5%  
89.5%  
90%  
C37/C40, P32  
C37/C40, P32  
C37/C40, P32  
C37/C40, P32  
C37/C40, P32  
C37/C40, P32  
C37/C40, P32  
C37/C40, P32  
C37/C40, P32  
C37/C40, P32  
C37/C40, P32  
C37/C40, P32  
C37/C40, P32  
C37/C40, P32  
C37/C40, P32  
75  
45/1.2 88.5%  
80/3.1 87.5%  
100  
75  
45/1.6  
50/3.5  
50/1.7  
90/4.4  
80/2.9  
88%  
89%  
89%  
89%  
88%  
100  
100  
130  
130  
75  
91%  
5
91%  
12  
12  
3.3  
3.3  
3.3  
5
0.25%  
0.25%  
0.125%  
0.125%  
0.125%  
0.25%  
0.1%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.25%  
0.4%  
90.5%  
90%  
10  
15  
20  
20  
15  
15  
8
45/1.2 88.5%  
80/3.1 87.5%  
90.5%  
89.5%  
90%  
100  
75  
To Be Discontinued*  
To Be Discontinued*  
45/1.6  
50/3.5  
50/1.7  
90/4.4  
80/2.9  
88%  
89%  
89%  
89%  
88%  
100  
100  
130  
130  
91%  
5
91%  
12  
12  
0.25%  
0.25%  
0.25%  
0.25%  
90.5%  
90%  
To Be Discontinued*  
10  
*LAST TIME BUY: 4/1/2018. CLICK HERE FOR DISCONTINUANCE NOTICES.  
Typical at TA = +25°C under nominal line voltage and full-load conditions. All models are  
specified with an external 1µF multi-layer ceramic and 10µF capacitors across their output pins.  
Ripple/Noise (R/N) measured over a 20MHz bandwidth.  
Nominal line voltage, no load/full load condition.  
Please refer to the Part Number Structure when ordering.  
Not all model number combinations are available. Consult Murata Power Solutions.  
Devices have no minimum-load requirements and will regulate under no-load conditions.  
Regulation specifications describe the output voltage deviation as the line voltage or load is  
varied from its nominal/midpoint value to either extreme. (Load step = 50%.)  
ULQ-12/8-D24N-C  
ULQ-12/8-D24NL1-C  
ULQ-12/8-D24NL2-C  
ULQ-12/8-D24P-C  
ULQ-12/8-D24PL1-C  
ULQ-3.3/15-D48N-C  
ULQ-3.3/15-D48P-C  
ULQ-3.3/15-D48PL1-C  
ULQ-12/10-D48NL2-C  
ULQ-3.3/20-D24N-C  
ULQ-3.3/20-D24NL2-C  
ULQ-3.3/20-D24P-C  
ULQ-3.3/20-D24PL1-C  
ULQ-12/10-D48PL2-C  
ULQ-3.3/20-D24PL2-C  
ULQ-5/15-D48N-C  
ULQ-5/15-D48P-C  
ULQ-5/15-D48PL2-C  
ULQ-12/10-D48NL1-C  
P A R T N U M B E R S T R U C T U R E  
- C  
RoHS-6 compliant  
U LQ - 3.3 / 20 D48 N M Lx  
-
Output  
Configuration  
Pin Length Option  
Quarter-Brick Package  
Nominal Output Voltage  
Surface-Mount Package  
(see list above)  
Maximum Rated Output  
Remote On/Off Control Logic  
Input Voltage Range  
See page 16 for complete Part Number Structure.  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 2 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
Environmental  
Performance/Functional Specifications  
Typical @ TA = +25°C under nominal line voltage, full-load conditions, unless noted. (1)  
Input  
(13)  
Calculated MTBF:  
TBD million hours  
Input Voltage Range: (2)  
D24 Models  
D48 Models  
(4) (14)  
Operating Temperature (Ambient):  
See derating curves  
–40 to +85°C with derating  
18-36 Volts (24V nominal)  
36-75 Volts (48V nominal)  
(4) (7)  
PCB Temperature:  
Maximum Allowable  
Thermal Shutdown  
Overvoltage Shutdown  
D24 Models  
D48 Models  
+100°C  
+105 to 120°C, +115°C typical  
37-41 Volts (39V typical)  
None (3)  
Physical  
See Mechanical Dimensions  
Start-Up Threshold: (4)  
D24 Models  
D48 Models  
Dimensions  
16-18 Volts (17.5V typical)  
34-36 Volts (35V typical)  
Pin Material (through-hole)  
Gold-plated copper alloy with nickel  
underplate  
Undervoltage Shutdown: (4)  
D24 Models  
D48 Models  
Pad Material (SMT)  
Weight:  
Copper alloy, pure tin over nickel underplate  
1 ounce (28 grams)  
15.5-17.5 Volts (16.75V typical)  
32.5-34.5 Volts (33.5V typical)  
Primary-to-Secondary Insulation Level Basic  
Input Current:  
EMI Conducted and Radiated  
FCC Part 15, EN55022 may require  
external filter  
Normal Operating Conditions  
Inrush Transient  
Short Circuit  
See Ordering Guide  
0.05A2 sec maximum  
50-100mA  
Safety  
UL/IEC/EN60950-1 CSA-C22.2 No. 234  
Standby Mode:  
Off, UV, Thermal Shutdown  
4-10mA  
Input Reflected Ripple Current (5)  
Internal Input Filter Type  
8-50mAp-p  
(1)  
All models are tested and specified with external output capacitors (1µF ceramic in parallel  
with 10µF tantalum), unless otherwise noted. These converters have no minimum-load require-  
ments and will effectively regulate under no-load conditions.  
Pi  
Reverse-Polarity Protection (3)  
1 minute duration, 5A maximum  
(2)  
(3)  
(4)  
(5)  
Contact Murata Power Solutions for input voltage ranges other than those listed.  
See Absolute Maximum Ratings for allowable input voltages.  
(6)  
Remote On/Off Control (Pin 2):  
Positive Logic ("P" Suffix Models)  
On = open, open collector or  
3.5-13V applied  
See Technical Notes/Performance Curves for additional explanations and details.  
Input Ripple Current is tested/specified over a 5-20MHz bandwidth with an external 33µF input  
Off = pulled low to 0-0.8V IIN = 6mA max.  
On = pulled low to 0-0.8V IIN = 6mA max.  
Off = open, open collector or  
3.5-13V applied  
capacitor and a simulated source impedance of 220µF and 12µH. See I/O Filtering, Input  
Ripple Current and Output Noise for details.  
(6)  
Negative Logic ("N" Suffix Models)  
The On/Off Control is designed to be driven with open-collector (or equivalent) logic or the  
application of appropriate voltages (referenced to –Input (pin 1)). See Remote On/Off Control  
for more details.  
(7)  
Output  
All models are fully operational and meet published specifications, including "cold start," at –40°C.  
Minimum Loading  
No load  
(8)  
Extreme Accuracy refers to the accuracy of either trimmed or untrimmed output voltages over  
all normal operating ranges and combinations of input voltage, output load and temperature.  
VOUT Accuracy (Full Load):  
Initial  
(9)  
See Output Trimming for detailed trim equations.  
1.25% maximum  
0.02% per °C  
3%  
(10)  
The Current-Limit Inception point is the output current level at which the ULQ’s power-limiting  
Temperature Coefficient  
Extreme (8)  
circuitry drops the output voltage 2% from its initial value. See Output Current Limiting and  
Short-Circuit Protection for more details.  
(11)  
VOUT Trim Range (9)  
+10%, –20%  
See Performance Curves for additional information.  
(12)  
(4)  
For the Start-Up Time specifications, output settling is defined by the output voltage having  
reached 1% of its final value.  
(13)  
Remote Sense Compensation  
+10%  
Ripple/Noise (20MHz BW)  
Line/Load Regulation  
Efficiency  
See Ordering Guide  
See Ordering Guide  
See Ordering Guide  
MTBF’s are calculated using Telcordia (Bellcore) Method 1 Case 3, ground fixed conditions,  
+40°C case temperature, and full-load conditions.  
Isolation Voltage: Input-to-Output  
2000Vdc minimum, D24 models  
2250Vdc minimum, D48 models  
Absolute Maximum Ratings  
Input Voltage:  
Continuous:  
D24V Models  
See OVP  
NA  
D48V Models  
81 Volts  
100 Volts  
Isolation Resistance  
Isolation Capacitance  
100M  
470pF  
Transient (100msec):  
Current Limit Inception (98% VOUT) (10)  
After warmup  
Input Reverse-Polarity Protection  
Input Current must be <5A. 1 minute  
duration. Fusing recommended.  
+125% of maximum rated current  
Short Circuit: (4)  
Current  
Duration  
Output Current  
Current limited. Devices can withstand  
an indefinite output short circuit.  
Hiccup with auto-restart  
Continuous  
On/Off Control (Pin 2) Max. Voltages  
Referenced to –Input (pin 1)  
Overvoltage Protection: (4)  
OVP method  
VOUT nominal +20%  
Comparator magnetic feedback  
–0.3 to +13.6 Volts  
–55 to +125°C  
Storage Temperature  
Dynamic Characteristics  
Dynamic Load Response (11)  
(50% Load Step)  
Lead Temperature  
Through-hole Soldering  
SMT Soldering  
+300°C, 10 seconds  
Refer to solder profile  
60-300µsec, model dependent  
Start-Up Time: (4) (12)  
VIN to VOUT; On/Off to VOUT  
30msec typical, 50msec maximum  
160-300kHz, model dependent  
4700 to 10,000µF, model dependent  
These are stress ratings. Exposure of devices to any of these conditions may adversely  
affect long-term reliability. Proper operation under conditions other than those listed in the  
Performance/Functional Specifications Table is not implied, nor recommended.  
Switching Frequency  
Maximum Capacitive Load  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 3 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
A built-in hysterisis for all models will not allow the converter to restart until  
T E C H N I C A L N O T E S  
Input Fusing  
the input voltage is sufficiently reduced.  
Certain applications and/or safety agencies may require the installation of  
fuses at the inputs of power conversion components. Fuses should also be  
used if the possibility of sustained, non-current-limited, input-voltage polarity  
reversals exists. For DATEL ULQ series DC-DC converters, we recommend  
the use of a time delay fuse, installed in the ungrounded input supply line,  
with a value no greater than 20 Amps.  
All 48VIN models have the overvoltage shutdown function disabled, based  
on requirements to withstand brief input surges and transients to 100V for  
up to 100msec without voltage interruption. Contact DATEL to have input  
overvoltage shutdown for 48VIN models enabled.  
Input Source Impedance  
As a rule of thumb however, we recommend the use of a normal-blow or  
slow-blow fuse with a typical value about twice the maximum input current,  
calculated at low line with the converter's minimum efficiency.  
The input of ULQ converters must be driven from a low ac-impedance  
source. The DC-DC's performance and stability can be compromised by the  
use of highly inductive source impedances. The input circuit shown in Figure  
2 is a practical solution that can be used to minimize the effects of induc-  
tance in the input traces. For optimum performance, components should be  
mounted close to the DC-DC converter.  
All relevant national and international safety standards and regulations must  
be observed by the installer. For system safety agency approvals, the  
converters must be installed in compliance with the requirements of the end-  
use safety standard, i.e. IEC/EN/UL60950.  
I/O Filtering, Input Ripple Current, and Output Noise  
Input Reverse-Polarity Protection  
All models in the ULQ Series are tested/specified for input reflected ripple  
current and output noise using the specified external input/output compo-  
nents/circuits and layout as shown in the following two figures. External input  
capacitors (CIN in Figure 2) serve primarily as energy-storage elements,  
minimizing line voltage variations caused by transient IR drops in conductors  
from backplane to the DC-DC. Input caps should be selected for bulk capaci-  
tance (at appropriate frequencies), low ESR, and high rms-ripple-current  
ratings. The switching nature of DC-DC converters requires that dc voltage  
sources have low ac impedance as highly inductive source impedance  
can affect system stability. In Figure 2, CBUS and LBUS simulate a typical dc  
voltage bus.Your specific system configuration may necessitate additional  
considerations.  
If the input voltage polarity is accidentally reversed, an internal diode will  
become forward biased and likely draw excessive current from the power  
source. If this source is not current limited or the circuit appropiately fused, it  
could cause permanent damage to the converter.  
Input Undervoltage Shutdown and Start-Up Threshold  
Under normal start-up conditions, devices will not begin to regulate properly  
until the ramping-up input voltage exceeds the Start-Up Threshold Voltage.  
Once operating, devices will not turn off until the input voltage drops below  
the Undervoltage Shutdown limit. Subsequent re-start will not occur until the  
input is brought back up to the Start-Up Threshold. This built in hysteresis  
prevents any unstable on/off situations from occurring at a single input  
voltage.  
TO  
CURRENT  
PROBE  
OSCILLOSCOPE  
1
+VIN  
–VIN  
Start-Up Time  
L
BUS  
+
The VIN to VOUT Start-Up Time is the time interval between the point at which  
the ramping input voltage crosses the Start-Up Threshold and the fully loaded  
output voltage enters and remains within its specified accuracy band. Actual  
measured times will vary with input source impedance, external input capaci-  
tance, and the slew rate and final value of the input voltage as it appears at  
the converter. The ULQ Series implements a soft start circuit to limit the duty  
cycle of its PWM controller at power up, thereby limiting the input inrush current.  
V
IN  
C
BUS  
CIN  
3
C
IN = 33µF, ESR < 700m@ 100kHz  
BUS = 220µF, ESR < 100m@ 100kHz  
C
L
BUS = 12µH  
Figure 2. Measuring Input Ripple Current  
The On/Off Control to VOUT start-up time assumes the converter has its  
nominal input voltage applied but is turned off via the On/Off Control pin. The  
specification defines the interval between the point at which the converter is  
turned on (released) and the fully loaded output voltage enters and remains  
within its specified accuracy band.  
In critical applications, output ripple/noise (also referred to as periodic and  
random deviations or PARD) may be reduced below specified limits using fil-  
tering techniques, the simplest of which is the installation of additional exter-  
nal output capacitors. They function as true filter elements and should be  
selected for bulk capacitance, low ESR and appropriate frequency response.  
All external capacitors should have appropriate voltage ratings and be  
located as close to the converter as possible. Temperature variations for all  
relevant parameters should also be taken carefully into consideration. The  
most effective combination of external I/O capacitors will be a function of  
line voltage and source impedance, as well as particular load and layout  
conditions. Our Applications Engineers can recommend potential solutions  
and discuss the possibility of our modifying a given device's internal filtering  
to meet your specific requirements. Contact our Applications Engineering  
Group for additional details.  
Similar to the VIN to VOUT start-up, the On/Off Control to VOUT start-up  
time is also governed by the internal soft start circuitry and external load  
capacitance. The difference in start up time from VIN to VOUT and from On/Off  
Control to VOUT is therefore insignificant.  
Input Overvoltage Shutdown  
All 24VIN ULQ DC-DC's are equipped with input overvoltage protection. Input  
voltages exceeding the input overvoltage shutdown specification listed in the  
Performance/Functional Specifications will cause the device to shutdown.  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 4 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
tion, the output voltage will decrease proportionately with increases in output  
current, thereby maintaining somewhat constant power dissipation. This is  
commonly referred to as power limiting. Current limit inception is defined as  
the point at which the full-power output voltage falls below the specified toler-  
ance. See Performance/Functional Specifications. If the load current, being  
drawn from the converter, is significant enough, the unit will go into a short  
circuit condition as described below.  
7
8
+SENSE  
+VOUT  
RLOAD  
SCOPE  
C1  
C2  
4
5
Short Circuit Condition  
–VOUT  
–SENSE  
When a converter is in current-limit mode, the output voltage will drop as  
the output current demand increases. If the output voltage drops too low, the  
magnetically coupled voltage used to develop primary side voltages will also  
drop, thereby shutting down the PWM controller. Following a time-out period,  
the PWM will restart causing the output voltage to begin ramping to their  
appropriate value. If the short-circuit condition persists, another shutdown  
cycle will be initiated. This on/off cycling is referred to as "hiccup" mode.  
The hiccup cycling reduces the average output current, thereby preventing  
internal temperatures from rising to excessive levels. The ULQ Series is  
capable of enduring an indefinite short circuit output condition.  
C1 = 1µF  
C2 = 10µF TANTALUM  
LOAD 2-3 INCHES (51-76mm) FROM MODULE  
Figure 3. Measuring Output Ripple/Noise (PARD)  
Floating Outputs  
Since these are isolated DC-DC converters, their outputs are "floating" with  
respect to their input. Designers will normally use the –Output (pin 4) as the  
ground/return of the load circuit.You can however, use the +Output (pin 8) as  
ground/return to effectively reverse the output polarity.  
F E A T U R E S A N D O P T I O N S  
Remote Sense  
Minimum Output Loading Requirements  
Note: The Sense and VOUT lines are internally connected through low-value  
resistors. Nevertheless, if the sense function is not used for remote regulation  
the user should connect the +Sense to +VOUT and -Sense to –VOUT at the  
DC-DC converter pins.  
ULQ converters employ a synchronous-rectifier design topology and all  
models regulate within spec and are stable under no-load to full load condi-  
tions. Operation under no-load conditions however might slightly increase the  
output ripple and noise.  
ULQ series converters employ a sense feature to provide point of use regula-  
tion, thereby overcoming moderate IR drops in pcb conductors or cabling.  
The remote sense lines carry very little current and therefore require minimal  
cross-sectional-area conductors. The sense lines, which are capacitively  
coupled to their respective output lines, are used by the feedback control-loop  
to regulate the output. As such, they are not low impedance points and must  
be treated with care in layouts and cabling. Sense lines on a pcb should be  
run adjacent to dc signals, preferably ground. In cables and discrete wiring  
applications, twisted pair or other techniques should be implemented.  
Thermal Shutdown  
The ULQ converters are equipped with thermal-shutdown circuitry. If envi-  
ronmental conditions cause the temperature of the DC-DC converter to rise  
above the designed operating temperature, a precision temperature sensor  
will power down the unit. When the internal temperature decreases below the  
threshold of the temperature sensor, the unit will self start. See Performance/  
Functional Specifications.  
Output Overvoltage Protection  
ULQ series converters will compensate for drops between the output voltage  
at the DC-DC and the sense voltage at the DC-DC provided that:  
The ULQ output voltage is monitored for an overvoltage condition using a  
comparator. The signal is optically coupled to the primary side and if the  
output voltage rises to a level which could be damaging to the load, the sens-  
ing circuitry will power down the PWM controller causing the output voltage  
to decrease. Following a time-out period the PWM will restart, causing the  
output voltage to ramp to its appropriate value. If the fault condition persists,  
and the output voltage again climbs to excessive levels, the overvoltage  
circuitry will initiate another shutdown cycle. This on/off cycling is referred to  
as "hiccup" mode.  
[VOUT(+) –VOUT(–)] – [Sense(+) –Sense (–)] 10% VOUT  
Contact and PCB resistance  
losses due to IR drops  
8
1
+VOUT  
+VIN  
IOUT  
7
+SENSE  
Sense Current  
2
3
ON/OFF  
CONTROL  
6
5
TRIM  
–SENSE  
–VOUT  
LOAD  
Sense Return  
Current Limiting  
IOUT Return  
As soon as the output current increases to approximately 130% of its rated  
value, the DC-DC converter will go into a current-limiting mode. In this condi-  
4
–VIN  
Contact and PCB resistance  
losses due to IR drops  
Figure 4. Remote Sense Circuit Configuration  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 5 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
A single resistor connected from the Trim pin (pin 6) to the +Sense (pin 7) will  
increase the output voltage. A resistor connected from the Trim Pin (pin 6) to  
the –Sense (pin 5) will decrease the output voltage.  
Output overvoltage protection is monitored at the output voltage pin, not the  
Sense pin. Therefore, excessive voltage differences between VOUT and Sense  
in conjunction with trim adjustment of the output voltage can cause the over-  
voltage protection circuitry to activate (see Performance Specifications for  
overvoltage limits). Power derating is based on maximum output current and  
voltage at the converter's output pins. Use of trim and sense functions can  
cause output voltages to increase, thereby increasing output power beyond  
the conveter's specified rating, or cause output voltages to climb into the  
output overvoltage region. Therefore, the designer must ensure:  
Trim adjustments greater than the specified +10%/–20% can have an  
adverse affect on the converter’s performance and are not recommended.  
Excessive voltage differences between VOUT and Sense, in conjunction with  
trim adjustment of the output voltage, can cause the overvoltage protection  
circuitry to activate (see Performance Specifications for overvoltage limits).  
Temperature/power derating is based on maximum output current and volt-  
age at the converter's output pins. Use of the trim and sense functions can  
cause output voltages to increase, thereby increasing output power beyond  
the converter's specified rating, or cause output voltages to climb into the  
output overvoltage region. Therefore:  
(VOUT at pins) × (IOUT) rated output power  
Trimming Output Voltage  
ULQ converters have a trim capability (pin 6) that enables users to adjust  
the output voltage from +10% to –20% (refer to the trim equations and trim  
graphs that follow). Adjustments to the output voltage can be accomplished  
via a trim pot (Figure 5) or a single fixed resistor as shown in Figures 6 and 7.  
A single fixed resistor can increase or decrease the output voltage depending  
on its connection. Resistors should be located close to the converter and  
have TCR's less than 100ppm/°C to minimize sensitivity to changes in  
temperature. If the trim function is not used, leave the trim pin open.  
(VOUT at pins) x (IOUT) rated output power  
The Trim pin (pin 6) is a relatively high impedance node that can be suscep-  
tible to noise pickup when connected to long conductors in noisy environ-  
ments. In such cases, a 0.22µF capacitor can be added to reduce this long  
lead effect.  
Trim Equations  
ULQ-1.2/15-D48 & ULQ-1.2/25-D48  
1.308(VO 0.793)  
VO 1.2  
1.037  
1.413  
1.413  
10.2  
10.2  
RTUP (k) =  
RTUP (k) =  
RTUP (k) =  
RTDOWN (k) =  
1.2 VO  
8
1
+VOUT  
+VIN  
ULQ-1.5/15-D48, ULQ-1.5/25-D24 & D48  
7
+SENSE  
6.23(VO 1.226)  
7.64  
1.5 VO  
6
10.2  
2
5-22  
TURNS  
RTDOWN (k) =  
ON/OFF  
CONTROL  
TRIM  
–SENSE  
–VOUT  
LOAD  
VO 1.5  
5
4
ULQ-1.8/15-D48, ULQ-1.8/25-D24 & D48  
3
9.12  
1.8 VO  
7.44(VO 1.226)  
–VIN  
10.2  
RTDOWN (k) =  
VO 1.8  
Figure 5.Trim Connections Using A Trimpot  
ULQ-2/15-D48, ULQ-2/15-D24 & D48  
10.15  
2 VO  
8.28(VO 1.226)  
10.2  
10.2  
8
10.2  
RTDOWN (k) =  
RTUP (k) =  
RTUP (k) =  
1
+VOUT  
+VIN  
VO 2  
7
ULQ-2.5/15-D48, ULQ-2.5/20-D24 & D48  
+SENSE  
2
6
10(VO 1.226)  
VO 2.5  
12.26  
2.5 VO  
ON/OFF  
CONTROL  
TRIM  
LOAD  
10.2  
RTDOWN (k) =  
RTRIM UP  
5
–SENSE  
ULQ-3.3/15-D48, ULQ-3.3/20-D24 & D48  
3
4
–VIN  
–VOUT  
16.31  
13.3(VO 1.226)  
10.2  
10.2  
10.2  
10.2  
RTDOWN (k) =  
RTUP (k) =  
RTUP (k) =  
RTUP (k) =  
3.3 VO  
VO 3.3  
Figure 6.Trim Connections To Increase Output Voltages Using Fixed Resistors  
ULQ-5/15-D24, -D48  
8
25.01  
20.4(VO 1.226)  
VO 5  
1
+VOUT  
+VIN  
10.2  
RTDOWN (k) =  
5 VO  
7
+SENSE  
ULQ-12/8-D24, ULQ-12/10-D48  
2
3
6
5
4
ON/OFF  
CONTROL  
TRIM  
–SENSE  
–VOUT  
LOAD  
60.45  
49.6(VO 1.226)  
RTRIM DOWN  
10.2  
RTDOWN (k) =  
12 VO  
VO 12  
–VIN  
Note: Resistor values are in k. Adjustment accuracy is subject to resistor  
tolerances and factory-adjusted output accuracy. VO = desired output voltage.  
Figure 7.Trim Connections To Decrease Output Voltages Using Fixed Resistors  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 6 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
Trim-Up Resistance vs. Percentage Increase in Output Voltage  
Model ULQ-2.5  
1 x 107  
1 x 106  
1 x 105  
Model ULQ-1.5  
1 x 107  
1 x 106  
1 x 105  
1 x104  
1 x104  
1 x103  
0
1
2
3
4
5
6
7
8
9
10  
0
1
2
3
4
5
6
7
8
9
10  
VOUT INCREASE (%)  
VOUT INCREASE (%)  
Model ULQ-3.3  
Model ULQ-1.8  
1 x 107  
1 x 107  
1 x 106  
1 x 105  
1 x104  
1 x 106  
1 x 105  
1 x104  
0
1
2
3
4
5
6
7
8
9
10  
0
1
2
3
4
5
6
7
8
9
10  
VOUT INCREASE (%)  
VOUT INCREASE (%)  
Trim-Down Resistance vs. Percentage Decrease  
Model ULQ-2  
1 x 107  
in Output Voltage  
1 x 107  
Model ULQ-1.5  
Model ULQ-1.8  
Model ULQ-2  
Model ULQ-2.5  
Model ULQ-3.3  
1 x 106  
1 x 105  
1 x104  
1 x 106  
1 x 105  
0
1
2
3
4
5
6
7
8
9
10  
1 x104  
0
2
4
6
8
10  
12  
14  
16  
18  
20  
VOUT INCREASE (%)  
VOUT DECREASE (%)  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 7 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
On/Off Control ("P" or "N" suffix)  
The input-side, remote On/Off Control function (pin 2) can be ordered to  
operate with either logic type:  
+VIN  
1
2
+VCC  
"P" suffix: Standard models are equipped with Positive-logic and these  
devices are enabled when pin 2 is left open (or is pulled high, applying +3.5V  
to +13 with respect to –Input, pin 1) as per Figure 8. Positive-logic devices  
are disabled when pin 2 is pulled low (0 to 0.8V with respect to –Input).  
ON/OFF  
CONTROL  
"N" suffix: Optional Negative-logic devices are off when pin 2 is left open (or  
pulled high, applying +3.5V to +13V), and on when pin 2 is pulled low (0 to  
0.8V) with respect to –Input as shown in Figure 9.  
–VIN  
3
Figure 9. Driving the Negative Logic On/Off Control Pin  
+VIN  
1
2
Dynamic control of the remote on/off function is best accomplished with  
a mechanical relay or an open-collector/open-drain drive circuit (optically iso-  
lated if appropriate). The drive circuit should be able to sink appropriate cur-  
rent (see Performance Specifications) when activated and withstand appro-  
priate voltage when deactivated. Applying an external voltage to pin 2 when  
no input power is applied to the converter can cause permanent damage  
to the converter.  
13V CIRCUIT  
5V CIRCUIT  
ON/OFF  
CONTROL  
–VIN  
3
Figure 8. Driving the Positive Logic On/Off Control Pin  
Surface-Mount Package ("M" suffix)  
DATEL is not exempted from the Laws of Physics. And we do not have magic  
solders no one else has. Nevertheless, we have a simple and practical,  
straightforward approach that works. We assemble our SMT DC-DC's on  
a hightemperature, plastic lead-frame (nylon 46, UL94V-0 rated) using a  
high-temperature (+216°C), lead-free alloy (Sn96.2%, Ag2.5%, Cu0.8%,  
Sb0.5%). The lead-frame ensures coplanarity (to within 0.004 in.) of the unit's  
tin-plated (150 microinches) copper leads and also supports a removable  
heat shield.  
DATEL's ULQ series SMT DC-DC converters are the only higher-power (to  
66W) DC-DC's that can be automatically "pick-and-placed" using standard  
vacuum-pickup equipment and subsequently reflowed using high-tempera-  
ture, lead-free solder.  
Virtually all SMT DC-DC's today are unprotected "open-frame" devices  
assembled by their vendors with high-temperature solder (usually Sn96.5/  
Ag3.5 with a melting point +221°C) so that you may attach them to your  
board using low-temperature solder (usually Sn63/Pb37 with a melting point  
of +183°C). Conceptually straightforward, this "stepped" solder approach has  
its limitations . . . and is clearly out of step with an industry trending toward  
the broad use of lead-free solders. No need to experiment and develop reflow  
profiles that ensure the components on their DC-DC never exceed 215-  
216°C. If those components get too hot, "double-reflow" could compromise  
the reliability of their solder joints. Virtually all these devices demand you  
"cool down" the Sn63 profile you are likely using today.  
The disposable heat shield, which has a cutaway exposing the package  
leads, provides thermal insulation to internal components during reflow and  
also doubles as the vacuum pick-up location. The insulation properties of the  
heat shield are so effective that temperature differentials as high as 50°C  
develop inside-to-outside the shield. Oven temperature profiles with peaks of  
250-260°C and dwell times exceeding 2 minutes above 221°C (the melting  
point of Sn96.5/Ag3.5) are easily achieved. DATEL's new-generation SMT  
units are shipped in stackable, JEDEC-style plastic.  
250  
200  
150  
100  
50  
Heat Shield  
Test Board  
Air Under Shield  
Z1  
Z2  
Z3  
Z4  
Z5  
Z6  
300  
Z7  
Seconds  
100  
200  
400  
500  
600  
Figure 11. Recommended Solder Profile  
(When The Heat-shield Temperature Exceeds +250°C,The Air Within Is 50°C Cooler)  
Figure 10. ULQ SMT DC-DC  
With Disposable Heat Shield  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 8 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
Typical Performance Curves, 1.5V Models  
ULQ-1.5/25-D24 Efficiency vs. Line Voltage and Load Current  
ULQ-1.5/25-D24  
Output Current vs. Ambient Temperature  
(No air flow)  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
30  
25  
20  
15  
10  
5
V
IN = 18V  
VIN = 18V  
VIN = 24V  
V
IN = 24V  
VIN = 36V  
V
IN = 36V  
0
–40  
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100  
2.5  
5
7.5  
10  
12.5  
15  
17.5  
20  
22.5  
25  
Ambient Temperature (°C)  
Load Current (Amps)  
ULQ-1.5/15-D48 Efficiency vs. Line Voltage and Load Current  
ULQ-1.5/15-D48  
Output Current vs. Ambient Temperature  
(No air flow)  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
68  
66  
18  
15  
12  
9
VIN = 36V  
V
IN = 36V  
VIN = 48V  
V
IN = 48V  
6
VIN = 75V  
3
V
IN = 75V  
0
–40  
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100  
Ambient Temperature (°C)  
1.5  
3
4.5  
6
7.5  
9
10.5  
12  
13.5  
15  
Load Current (Amps)  
ULQ-1.5/25-D48 Efficiency vs. Line Voltage and Load Current  
ULQ-1.5/25-D48  
Output Current vs. Ambient Temperature  
(VIN = 48V, air flow direction from Input pin to Output pin)  
91  
89  
87  
85  
83  
81  
79  
77  
75  
73  
30  
25  
20  
15  
10  
5
0 lfm  
V
IN = 36V  
100 lfm  
V
IN = 48V  
200 lfm  
V
IN = 75V  
0
–40  
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100  
2.5  
5
7.5  
10  
12.5  
15  
17.5  
20  
22.5  
25  
Load Current (Amps)  
Ambient Temperature (°C)  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 9 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
Typical Performance Curves, 1.8V Models  
ULQ-1.8/15-D48 Efficiency vs. Line Voltage and Load Current  
ULQ-1.8/15-D48  
Output Current vs. Ambient Temperature  
(No air flow)  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
68  
18  
15  
12  
9
VIN = 36V  
VIN = 48V  
V
IN = 36V  
6
V
IN = 48V  
VIN = 75V  
3
V
IN = 75V  
0
–40  
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100  
Ambient Temperature (°C)  
1.5  
3
4.5  
6
7.5  
9
10.5  
12  
13.5  
15  
Load Current (Amps)  
ULQ-1.8/25-D24 Efficiency vs. Line Voltage and Load Current  
ULQ-1.8/25-D24  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
68  
Output Current vs. Ambient Temperature  
(No air flow)  
30  
25  
20  
15  
10  
5
V
IN = 18V  
VIN = 18V  
VIN = 24V  
V
IN = 24V  
V
IN = 36V  
VIN = 36V  
0
–40  
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100  
2.5  
5
7.5  
10  
12.5  
15  
17.5  
20  
22.5  
25  
Ambient Temperature (°C)  
Load Current (Amps)  
ULQ-1.8/25-D48 Efficiency vs. Line Voltage and Load Current  
ULQ-1.8/25-D48  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
68  
Output Current vs. Ambient Temperature  
(VIN = 48V, air flow direction from Input pin to Output pin)  
30  
25  
20  
15  
10  
5
0 lfm  
V
IN = 36V  
100 lfm  
200 lfm  
V
IN = 48V  
V
IN = 75V  
0
–40  
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100  
2.1  
4.2 6.25 8.3 10.4 12.5 14.6 16.7 18.75 20.8 22.9 25  
Load Current (Amps)  
Ambient Temperature (°C)  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 10 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
Typical Performance Curves, 2V Models  
ULQ-2/15-D48 Efficiency vs. Line Voltage and Load Current  
ULQ-2/15-D48  
Output Current vs. Ambient Temperature  
(No air flow)  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
68  
18  
15  
12  
9
VIN = 36V  
V
IN = 36V  
VIN = 48V  
6
V
IN = 48V  
VIN = 75V  
3
V
IN = 75V  
0
–40  
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100  
Ambient Temperature (°C)  
1.5  
3
4.5  
6
7.5  
9
10.5  
12  
13.5  
15  
Load Current (Amps)  
ULQ-2/25-D24 Efficiency vs. Line Voltage and Load Current  
ULQ-2/25-D24  
Output Current vs. Ambient Temperature  
(No air flow)  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
30  
25  
20  
15  
10  
5
V
IN = 18V  
VIN = 18V  
VIN = 24V  
V
IN = 24V  
VIN = 36V  
V
IN = 36V  
0
–40  
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100  
2.5  
5
7.5  
10  
12.5  
15  
17.5  
20  
22.5  
25  
Ambient Temperature (°C)  
Load Current (Amps)  
ULQ-2/25-D48 Efficiency vs. Line Voltage and Load Current  
ULQ-2/25-D48  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
Output Current vs. Ambient Temperature  
(VIN = 48V, air flow direction from Input pin to Output pin)  
30  
25  
20  
15  
10  
5
0 lfm  
V
IN = 36V  
100 lfm  
200 lfm  
V
IN = 48V  
V
IN = 75V  
0
–40  
0
22 26 30 34 38 42 46 50 54 58 62 66 70 74 78 82 86 90  
2.5  
5
7.5  
10  
12.5  
15  
17.5  
20  
22.5  
25  
Ambient Temperature (°C)  
Load Current (Amps)  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 11 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
Typical Performance Curves, 2.5V Models  
ULQ-2.5/15-D48 Efficiency vs. Line Voltage and Load Current  
ULQ-2.5/15-D48  
Output Current vs. Ambient Temperature  
(VIN = 48V, air flow direction from Input pin to Output pin)  
94  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
18  
15  
12  
9
Natural Convection  
100 lfm  
V
IN = 36V  
200 lfm  
300 lfm  
400 lfm  
6
V
IN = 48V  
3
V
IN = 75V  
0
–40  
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100  
1.5  
3
4.5  
6
7.5  
9
10.5  
12  
13.5  
15  
Ambient Temperature (°C)  
Load Current (Amps)  
ULQ-2.5/20-D48 Efficiency vs. Line Voltage and Load Current  
ULQ-2.5/20-D48  
93  
91  
89  
87  
85  
83  
81  
79  
77  
Output Current vs. Ambient Temperature  
(VIN = 48V, air flow direction from Input pin to Output pin)  
25  
20  
15  
10  
5
V
IN = 36V  
100 lfm  
200 lfm  
300 lfm  
V
IN = 48V  
V
IN = 75V  
400 lfm  
0
–40  
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100  
2
4
6
8
10  
12  
14  
16  
18  
20  
Load Current (Amps)  
Ambient Temperature (°C)  
ULQ-2.5/20-D24 Power Dissipation vs. Load Current  
11  
10  
9
8
7
6
5
4
3
2
1
VIN = 36V  
V
IN = 24V  
V
IN = 18V  
2
4
6
8
10  
12  
14  
16  
18  
20  
22  
Load Current (Amps)  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 12 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
Typical Performance Curves, 3.3V Models  
ULQ-3.3/15-D48  
ULQ-3.3/15-D48 Efficiency vs. Line Voltage and Load Current  
Output Current vs. Ambient Temperature  
(VIN = 48V, air flow direction from Input pin to Output pin)  
94  
90  
86  
82  
78  
74  
70  
18  
15  
12  
9
Natural Convection  
100 lfm  
V
IN = 36V  
200 lfm  
300 lfm  
400 lfm  
6
V
IN = 48V  
3
V
IN = 75V  
0
–40  
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100  
Ambient Temperature (°C)  
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15  
Load Current (Amps)  
ULQ-3.3/20-D24 Efficiency vs. Line Voltage and Load Current  
ULQ-3.3/20-D24  
Output Current vs. Ambient Temperature  
(VIN = 24V, air flow direction from Input pin to Output pin)  
93  
91  
89  
87  
85  
83  
81  
79  
77  
25  
20  
15  
10  
5
V
IN = 18V  
V
IN = 24V  
0 lfm  
100 lfm  
V
IN = 36V  
200 lfm  
400 lfm  
0
–40  
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100  
2
4
6
8
10  
12  
14  
16  
18  
20  
Ambient Temperature (°C)  
Load Current (Amps)  
ULQ-3.3/20-D48 Efficiency vs. Line Voltage and Load Current  
ULQ-3.3/20-D48  
Output Current vs. Ambient Temperature  
(VIN = 48V, air flow direction from Input pin to Output pin)  
93  
91  
89  
87  
85  
83  
81  
79  
77  
25  
20  
15  
10  
5
V
IN = 36V  
100 lfm  
V
IN = 48V  
200 lfm  
300 lfm  
V
IN = 75V  
0
–40  
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100  
2
4
6
8
10  
12  
14  
16  
18  
20  
Ambient Temperature (°C)  
Load Current (Amps)  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 13 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
Typical Performance Curves, 5V Models  
ULQ-5/15-D48N Efficiency Vs. Line Voltage And Load Current  
ULQ-5/15-D48N  
Maximum Output Current vs. Ambient Temperature  
(VIN = 48V, air flow direction from Input pin to Output pin)  
90.0  
80.0  
70.0  
60.0  
50.0  
40.0  
16  
15  
14  
13  
12  
11  
10  
9
Vin = 36V  
Vin = 48V  
100 lfm  
Vin = 60V  
Vin = 75V  
200 lfm  
300 lfm  
400 lfm  
–40  
0
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100  
1.5  
3
4.5  
6
7.5  
9
10.5  
12  
13.5  
15  
Ambient Temperature (°C)  
Load Current (Amps)  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 14 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
Typical Performance Curves, 12V Models  
ULQ-12/8-D24N  
Efficiency vs. Line Voltage and Load Current @25°C  
ULQ-12/8-D24  
Maximum Output Current vs. Ambient Temperature  
(VIN = 24V, transverse air flow direction from –Output to +Output pin)  
95  
90  
85  
80  
75  
70  
9
8
7
6
5
4
3
2
1
0
0 lfm  
200 lfm  
V
IN = 18V  
400 lfm  
600 lfm  
V
IN = 24V  
V
IN = 36V  
–40  
0
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
0.8  
1.6  
2.4  
3.2  
4
4.8  
5.6  
6.4  
7.2  
8
Load Current (Amps)  
ULQ-12/10-D48N  
Efficiency vs. Line Voltage and Load Current @25°C  
ULQ-12/10-D48  
Output Current vs. Ambient Temperature  
95  
90  
85  
80  
75  
70  
(VIN = 48V, air flow direction from Input pin to Output pin)  
10.5  
10  
9.5  
9
500 lfm  
8.5  
8
100 lfm  
200 lfm  
V
IN = 36V  
V
IN = 48V  
7.5  
7
300 lfm  
V
IN = 75V  
6.5  
6
–40  
0
22 26 30 34 38 42 46 50 54 58 62 66 70 74 78 82 86 90  
1
2
3
4
5
6
7
8
9
10  
Ambient Temperature (°C)  
Load Current (Amps)  
ULQ-12/10-D48 Power Dissipation vs. Load Current  
19  
17  
15  
13  
11  
9
VIN = 75V  
V
IN = 48V  
V
IN = 36V  
7
5
3
1
1
2
3
4
5
6
7
8
9
10  
Load Current (Amps)  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 15 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
SMT  
Lead  
For the surface mount versions of the ULQ, use the Recommended SMT Pad  
Layout illustration as a starting point to locate pads to mount the converter.  
This diagram is for the pads on the mating printed circuit board—it is not  
the dimensions of the lead terminals on the converter. Note: the pads are  
slightly larger than the lead terminals to accomodate solder wetting and  
meniscus. Also, your particular application may require some deviation from  
this diagram.  
SMT Unit  
PCB  
0.020  
(0.51)  
Copper Pad  
2.340 (59.44)  
1.975 (50.17)  
0.183  
(4.65)  
0.130  
(3.30)  
*
*
0.150 TYP.  
(3.81)  
0.020 REF.  
(0.51)  
* These two pads are for alignment and positioning only.  
They are not required for electrical contact.  
Recommended SMT Pad Layout  
P A R T N U M B E R S T R U C T U R E  
U LQ - 3.3 / 20 D48 N M Lx  
- C  
RoHS-6 Hazardous  
Substance Compliant  
-
Output  
Configuration:  
U = Unipolar  
Pin Length Option: Through-hole packages only  
Quarter-Brick Package  
L1 Pin length 0.110 0.010 inches (2.7ꢀ 0.25mm) ➀  
Nominal Output Voltage:  
1.2,1.5, 1.8, 2, 2.5, 3.3, 5, 12 Volts  
L2 Pin length 0.145 0.010 inches (3.68 0.25mm) ➀  
Blank is standard pin length  
Maximum Rated Output :  
Current in Amps  
Surface-Mount Package ➁ ➂  
Remote On/Off Control Logic  
Add "P" for positive logic  
(pin 2 open = converter on)  
Input Voltage Range:  
D24 = 18-36 Volts (24V nominal)  
D48 = 36-75 Volts (48V nominal)  
Add "N" for negative logic  
(pin 2 open = converter off)  
Positive logic is standard for D24 models. Nega-  
tive logic is standard for D48 models. Alternate  
logic may require a special order.  
Special quantity order is required; samples available with standard pin length only.  
SMT (M) versions not available in sample quantities.  
See list on pg. 2 using the C40 SMT package.  
Some model number combinations may not be available. See website or contact your local Murata sales representative.  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 16 of 17  
ULQ Models  
Single Output, Low-Profile, Quarter-Brick  
8-25 Amp Isolated DC-DC Converters  
M E C H A N I C A L S P E C I F I C A T I O N S  
2.30 (58.4)  
A
0.375 MAX.  
(9.53)  
OVERALL DIMENSIONS :  
2.22 (56.4)  
A
2.30 (58.4) x 1.45 (36.8) x 0.70 (17.8)  
BEFORE REMOVAL OF PROTECTIVE  
HEAT SHIELD  
PINS 1-3, 5-7:  
0.040 0.001  
(1.016 0.025)  
PINS 4, 8:  
0.062 0.001  
(1.575 0.025)  
0.35  
(8.9)  
PROTECTIVE  
HEAT SHIELD  
0.125  
(3.2)  
PLASTIC STANDOFFS  
ARE RELIEVED 0.030 (0.76)  
IN SOLDER JOINT AREA  
0.125 MIN.  
(3.2)  
Case C40  
0.150  
(3.81)  
2.00 (50.8)  
A
3 Surface-mount Package  
4
5
6
See page 16 for the  
recommneded pad  
layout dimensions.  
2
7
8
1
4
3
2
1
0.600  
(15.2)  
0.110  
(2.79)  
5
6
0.300  
(7.6)  
7
8
BOTTOM VIEW  
0.600 (15.2)  
4 EQ. SP. @ 0.150 (3.81)  
0.600  
(15.2)  
0.300  
(7.6)  
BOTTOM VIEW  
0.600 (15.2)  
4 EQ. SP.  
Case C37, Through-Hole Package @ 0.150 (3.81)  
DOSA-Compatible I/O Connections  
Dimensions are in inches (mm) shown for ref. only.  
Pin  
1
Function P32  
+Vin  
Pin  
5
Function P32  
–Sense  
Trim  
ꢀꢁꢂꢃd ꢄꢅꢆle ꢇꢃoꢈeꢉꢊꢂoꢅ  
2
Remote On/Off*  
–Vin  
6
3
7
+Sense  
+Vout  
4
–Vout  
8
Tolerances (unless otherwise specified):  
.XX ꢀ.ꢀ0 (ꢀ.ꢁ)  
.XXX ꢀ.ꢀꢂꢀ (ꢀ.0ꢁ)  
Angles 02  
*
The Remote On/Off can be provided with either positive ("P" suffix)  
or negative ("N" suffix) logic.  
Components are shown for reference only.  
This product is subject to the following operating requirements  
and the Life and Safety Critical Application Sales Policy:  
Refer to: http://www.murata-ps.com/requirements/  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
ISO 9001 and 14001 REGISTERED  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
notice.  
© 2017 Murata Power Solutions, Inc.  
www.murata-ps.com/support  
MDC_ULQ-15A.E04 Page 17 of 17  

相关型号:

ULQ-3.3/20-D24P-C

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid, PACKAGE-8
MURATA

ULQ-3.3/20-D24PML1-C

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid, ROHS COMPLIANT, QUARTER BRICK, SMT-8
MURATA

ULQ-3.3/20-D48N-C

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid, PACKAGE-8
MURATA

ULQ-3.3/20-D48NL1-C

DC-DC Regulated Power Supply Module, 1 Output, 66W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-8
MURATA

ULQ-5/15-D24P-C

DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, PACKAGE-8
MURATA

ULQ-5/15-D24PML1-C

DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, ROHS COMPLIANT, QUARTER BRICK, SMT-8
MURATA

ULQ-5/15-D24PML2-C

DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, ROHS COMPLIANT, QUARTER BRICK, SMT-8
MURATA

ULQ-5/15-D48N-C

DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, PACKAGE-8
MURATA

ULQ-5/15-D48NL1-C

DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-8
MURATA

ULQ-5/15-D48NL2-C

DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-8
MURATA

ULQ-5/15-D48NML1-C

DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, ROHS COMPLIANT, QUARTER BRICK, SMT-8
MURATA

ULQ-5/15-D48P-C

DC-DC Regulated Power Supply Module,
MURATA