ULS 60-Watt Series
s
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
FEATURES
ꢀSmall footprint DC/DC converter, ideal for
high current applications
Typical unit
ꢀTiny 0.9" x 1.3" x 0.40" open frame package
ꢀIndustry standard DOSA "brick" format
and pinout with surface mount option
PRODUCT OVERVIEW
The world of “brick” DC/DC converters has seen
a steady size reduction. The ULS series makes
another dramatic size shrink down to a “sixteenth- On/Off control may use a switch, transistor or digital
brick” width (0.9 inches) while still retaining up
to 66 Watt output and full 2250 Volt DC isolation.
The PC-board mount converter family accepts
minimum load is required. For systems requiring
controlled startup/shutdown, an external remote
ꢀ36-75 Volts DC input range
ꢀ2250 Volt Basic input/output isolation
(48V models)
logic. Remote Sense inputs compensate for resis-
tive line drops at high currents.
Many self-protection features on the ULS series
ꢀUp to 66 Watts total output power with
overtemperature shutdown
36 to 75 Volts DC inputs and delivers fixed outputs avoid both converter and external circuit hazards.
ꢀHigh efficiency synchronous rectifier forward
topology
regulated to within 0.2ꢀ. The ULS converters
are ideal for datacom and telecom applications,
cell phone towers, data centers, server farms and
network repeaters.
ULS outputs may be trimmed within 10ꢀ of
nominal output while delivering fast settling to
current step loads and no adverse effects from
higher capacitive loads. Excellent ripple and noise
specifications assure compatibility to circuits using
CPU’s, ASIC’s, programmable logic and FPGA’s. No
These include input undervoltage lockout and
overtemperature shutdown. The outputs current
limit using the “hiccup” autorestart technique and
the outputs may be short-circuited indefinitely.
Additional features include output overvoltage and
reverse conduction elimination.
ꢀStable no-load operation with no required
external components
ꢀOperating temperature range -40 to +85°C
with derating
The synchronous rectifier forward topology yields
high efficiency for minimal heat buildup and “no
fan” operation.
ꢀCertified to UL 60950-1, CSA-C22.2 No. 234,
EN60950-1 safety approvals, 2nd Edition
ꢀExtensive self-protection shut down features
+SENSE
(7)
+Vin
(1)
+Vout
(8)
SWITCH
CONTROL
-Vout
(4)
-Vin
(3)
PULSE
TRANSFORMER
-SENSE
(5)
INPUT
UNDER VOLTAGE,
OVER TEMPERATURE,
AND OUTPUT
OVER VOLTAGE
COMPARATORS
PWM
CONTROLLER
OPTO
ISOLATION
REFERENCE
ERROR AMP
Vout
TRIM
(6)
REMOTE
ON/OFF
CONTROL
(2)
Typical topology is shown
Figure 1. Simplified Block Diagram
For full details go to
www.murata-ps.com/rohs
REG.-Nr. D216
www.murata-ps.com/support
MDC_ULS Series.B27 Page 1 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
M
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE
Output
Input
R/N (mV pk-pk) N Regulation (max.) P
VIN Nom. Range IIN, no load
C76
Package
Efficiency
Root Model M
VOUT
IOUT
Power
IIN, full
(V)
(A, max.) (W)
(V)
(V)
(mA)
load (A)
Typ.
70
Max.
120
80
Line
Load
Min. Typ. Case (inches)
89ꢀ 90ꢀ 0.9x1.3x0.40
88ꢀ 90ꢀ 0.9x1.3x0.40
88ꢀ 91ꢀ 0.9x1.3x0.40
3.3
5
20
12
5
66
60
60
0.1ꢀ
0.2ꢀ
48
48
48
36-75
36-75
36-75
20
40
50
1.53
1.39
1.37
ULS-3.3/20-D48N-C
ULS-5/12-D48N-C
ULS-12/5-D48N-C
50
0.125ꢀ
0.125ꢀ
0.25ꢀ
0.25ꢀ
12
80
120
M
N
O
Please refer to the Part Number Structure when ordering.
These specifications are preliminary. Contact Murata Power Solutions for availability.
All specifications are at nominal line voltage and full load, +25°C unless otherwise noted. See detailed
specifications. Output capacitors are 1 μF ceramic multilayer in parallel with 10 μF electrolytic.
I/O caps are necessary for our test equipment and may not be needed for your application.
➃ Regulation specifications describe output voltage deviations from a nominal/midpoint value to either
extreme (50% load step).
PART NUMBER STRUCTURE
ULS - 3.3 / 20 - D48 N M H Lx - C
RoHS Hazardous Substance Compliance
(does not claim EU RoHS exemption 7b–lead in solder)
C = RoHS-6
Y = RoHS-5
Sixteenth Brick Series
Pin Length Option (Thru-hole only)
Blank = Standard pin length 0.180˝ (4.6mm)
L1 = 0.110˝ (2.79mm)*
L2 = 0.145˝ (3.68mm)*
*Special quantity order is required;
no sample quantities available.
Nominal Output Voltage:
Conformal Coating:
Blank = No coating, standard
H = Coating added, optional special order
Note:
SMT Version
Blank = Through-hole mount, no SMT
M = Surface mount (MSL Rating 3)
Maximum Rated Output Current
Current in Amps
Some model number combinations
may not be available. Please contact
Murata Power Solutions.
On/Off Control Logic:
N = Negative
P = Positive
Input Voltage Range:
D48 = 36-75 Volts (48V nominal)
www.murata-ps.com/support
MDC_ULS Series.B27 Page 2 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
FUNCTIONAL SPECIFICATIONS, ULS-3.3/20-D48
ABSOLUTE MAXIMUM RATINGS
Input Voltage, Continuous
Minimum
Typical/Nominal
Maximum
Units
Vdc
Conditions ➀
Full power operation
80
Operating or non-operating, tested:
100 mS max. duration
Input to output
Input Voltage, Transient
100
Vdc
Isolation Voltage
2250
Vdc
Vdc
Vdc
W
Input Reverse Polarity
On/Off Remote Control
Output Power
None, install external fuse
Power on, referred to -Vin
None
0
0
15
66.66
Current-limited, no damage,
short-circuit protected
Vin = Zero (no power)
Output Current
0
20
A
Storage Temperature Range
-55
125
°C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other
than those listed in the Performance/Functional Specifications Table is not implied or recommended.
INPUT
Operating voltage range
Recommended External Fuse
Start-up threshold, turn on
Undervoltage shutdown, turn off
Overvoltage protection
Reverse Polarity Protection
Internal Filter Type
36
48
75
4
35.5
33.5
Vdc
A
Vdc
Vdc
Vdc
Vdc
Fast blow
Rising input voltage
Falling input voltage
33.5
31.5
34.5
32.5
NA
None
Capacitive
12
None, install external fuse
Input current
Full Load Conditions
Low Line
Vin = nominal
Vin = minimum
1.53
2.08
1.56
2.15
A
A
Inrush Transient
0.05
150
30
5
A2-Sec.
mA
mA
Output in Short Circuit
No Load input current
Shut-Down Mode Input Current
300
100
15
Iout = minimum, unit=ON
mA
no filtering
Measured at input with specified filter
150
20
210
30
mAp-p
mAp-p
Reflected (back) ripple current ➁
Reflected (back) ripple current ➁
The converter will
start if the external
load pre-bias does
not exceed Vnom
Pre-biased startup
External output voltage < Vset
GENERAL and SAFETY
Efficiency
Vin=48V, full load
Vin=Min
89
86
90
88
ꢀ
ꢀ
Isolation
Isolation Voltage, input to output
Insulation Safety Rating
Isolation Resistance
Isolation Capacitance
2250
Vdc
basic
100
1000
MΩ
pF
UL-60950-1, CSA-C22.2 No.60950-1,
IEC/EN60950-1, 2nd Edition
Per MIL-HDBK-217F, ground benign,
Tambient=+40°C
Safety (meets the following requirements)
Calculated MTBF
Yes
TBD
3200
Hours x 103
Hours x 103
Per Telcordia SR332, issue 1, class 3, ground
fixed, Tambient=+40°C
Calculated MTBF ➃
DYNAMIC CHARACTERISTICS
19
Fixed Switching Frequency
Startup Time
Startup Time
480
500
5
5
520
15
10
KHz
mS
mS
Power on, Vout regulated
Remote ON to Vout regulated
50-75-50ꢀ load step, settling time to within
1ꢀ of Vout.
Dynamic Load Response
50
150
200
μSec
mV
Dynamic Load Peak Deviation
FEATURES and OPTIONS
Remote On/Off Control
“N” suffix:
same as above
150
Negative Logic, ON state
Negative Logic, OFF state
Control Current
ON = Pin grounded or external voltage
OFF = Pin open or external voltage
open collector/drain
-0.1
2.5
0.8
15
2
V
V
mA
1
www.murata-ps.com/support
MDC_ULS Series.B27 Page 3 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
FUNCTIONAL SPECIFICATIONS, ULS-3.3/20-D48 (CONT.)
FEATURES and OPTIONS (cont.)
Remote On/Off Control (cont.)
“P” suffix:
Conditions ➀
Minimum
Typical/Nominal
Maximum
Units
Positive Logic, ON state
Positive Logic, OFF state
Control Current
ON = Pin open or external voltage
OFF = Ground pin or external voltage
open collector/drain
3.5
0
15
1
2
V
V
mA
1
OUTPUT
Total Output Power
Voltage
Nominal Output Voltage ➂
Settling Accuracy
Output Voltage Range ➇
Overvoltage Protection
Remote Sense Compensation
Current
0
66
3.3
66.66
W
15
No trim
At 50ꢀ load
3.267
-1
-10
3.333
1
10
Vdc
ꢀ of Vset
User-adjustable
Via magnetic feedback
3.75
4.25
10
4.95
Vdc
ꢀ
18
Of Vset
Output Current Range
Minimum Load
Current Limit Inception
0
20
No minimum load
26
20
30
A
A
13
98ꢀ of Vnom., cold condition
22
Short Circuit ➄
Hiccup technique, autorecovery within 1ꢀ
of Vout
Short Circuit Current
6.6
A
Short Circuit Duration
(remove short for recovery)
Short circuit protection method
Regulation
Output shorted to ground, no damage
Hiccup current limiting
Continuous
Vin=min. to max., Vout=nom., nom load
Iout=min. to max
0.1
0.2
70
V
V
Line Regulation ➆
Load Regulation ➆
Ripple and Noise
5 Hz- 20 MHz BW
At all outputs
120
mV pk-pk
ꢀ of Vout./°C
Temperature Coefficient
0.02
Maximum Capacitive Loading
(10% ceramic, 90% Oscon)
Low ESR, .02 ohms max (resistive load)
1000
ꢁF
MECHANICAL (Through Hole Models)
Outline Dimensions
(Please refer to outline drawing)
Weight
Cxx case
WxLxH
1.3x0.9x0.4
33x22.9x10.2
0.58
Inches
mm
Ounces
Grams
Inches
mm
16.4
Through Hole Pin Diameter
.062 & .04
1.575 & 1.016
Gold-plated copper
alloy with nickel
underplate
50
Through Hole Pin Material
TH Pin Plating Metal and Thickness
Nickel subplate
Gold overplate
μ-inches
μ-inches
5
ENVIRONMENTAL
No derating, full power, 200 LFM,
no condensation
11
Operating Ambient Temperature Range
-40
85
°C
Storage Temperature
Operating Case Temp
Vin = Zero (no power)
No derating required
Measured at hotspot
-55
-40
110
125
120
120
°C
°C
°C
Thermal Protection/Shutdown
Electromagnetic Interference
Conducted, EN55022/CISPR22
Radiated, EN55022/CISPR22
RoHS rating
115
External filter is required
B
B
Class
Class
RoHS-6
www.murata-ps.com/support
MDC_ULS Series.B27 Page 4 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
TYPICAL PERFORMANCE DATA, ULS-3.3/20-D48
Efficiency vs. Line Voltage and Load Current @ 25°C
Maximum Current Temperature Derating at Sea Level
(VIN = 48V, longitudinal airflow)
25
20
15
10
5
100
95
90
Natural convection
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
2.0 m/s (400 LFM)
85
VIN = 75V
VIN = 48V
VIN = 36V
80
75
70
65
60
0
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (ºC)
3
4
6
8
10
12
14
16
18
20
Load Current (Amps)
(Resistive loads 50ꢀ with +25ꢀ step Vin=48V)
Transient Response (Load from 75ꢀ to 50ꢀ)
Enable Start-up
Transient Response (Load from 50ꢀ to 75ꢀ)
Enable Start-up (Vin=48V Iout=20A)
Enable Start-up (Vin=48V Iout=0A)
www.murata-ps.com/support
MDC_ULS Series.B27 Page 5 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
TYPICAL PERFORMANCE DATA, ULS-3.3/20-D48 (CONT.)
Ripple and Noise (1uF Ceramic and 10uF Tantalum Capcitors)
R/N Waveform (Vin=48V Iout=20A)
R/N Waveform (Vin=48V Iout=0A)
www.murata-ps.com/support
MDC_ULS Series.B27 Page 6 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
FUNCTIONAL SPECIFICATIONS, ULS-5/12-D48
ABSOLUTE MAXIMUM RATINGS
Input Voltage, Continuous
Minimum
Typical/Nominal
Maximum
Units
Vdc
Conditions ➀
Full power operation
80
Operating or non-operating, tested:
100 mS max. duration
Input Voltage, Transient
100
Vdc
Isolation Voltage
Input to output
None, install external fuse
Power on, referred to -Vin
2250
Vdc
Vdc
Vdc
W
Input Reverse Polarity
On/Off Remote Control
Output Power
None
0
0
15
60.6
Current-limited, no damage,
short-circuit protected
Vin = Zero (no power)
Output Current
0
12
A
Storage Temperature Range
-55
125
°C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other
than those listed in the Performance/Functional Specifications Table is not implied or recommended.
INPUT
Operating voltage range
Recommended External Fuse
Start-up threshold, turn on
Undervoltage shutdown, turn off
Overvoltage protection
Reverse Polarity Protection
Internal Filter Type
36
48
75
4
35.5
33.5
Vdc
A
Vdc
Vdc
Vdc
Vdc
Fast blow
Rising input voltage
Falling input voltage
33
31
34.5
32.5
NA
None
LC
12
None, install external fuse
Input current
Full Load Conditions
Low Line
Vin = nominal
Vin = minimum
1.39
1.85
1.43
1.91
A
A
Inrush Transient
0.05
100
40
5
A2-Sec.
mA
mA
Output in Short Circuit
No Load input current
Shut-Down Mode Input Current
200
80
10
Iout = minimum, unit=ON
mA
no filtering
Measured at input with specified filter
400
25
500
35
mAp-p
mAp-p
Reflected (back) ripple current ➁
Reflected (back) ripple current ➁
The converter will
start if the external
load pre-bias does
not exceed Vnom
Pre-biased startup
External output voltage < Vset
GENERAL and SAFETY
Efficiency
Vin=48V, full load
Vin=Min
88
88
90
90
ꢀ
ꢀ
Isolation
Isolation Voltage, input to output
Insulation Safety Rating
Isolation Resistance
Isolation Capacitance
2250
Vdc
basic
10
1000
MΩ
pF
UL-60950-1, CSA-C22.2 No.60950-1,
IEC/EN60950-1, 2nd Edition
Per MIL-HDBK-217F, ground benign,
Tambient=+40°C
Safety (meets the following requirements)
Calculated MTBF
Yes
TBD
3200
Hours x 103
Hours x 103
Per Telcordia SR332, issue 1, class 3, ground
fixed, Tambient=+40°C
Calculated MTBF ➃
DYNAMIC CHARACTERISTICS
19
Fixed Switching Frequency
Startup Time
Startup Time
400
10
10
KHz
mS
mS
Power on, Vout regulated
Remote ON to Vout regulated
50-75-50ꢀ load step, settling time to within
1ꢀ of Vout.
20
20
Dynamic Load Response
50
100
250
μSec
mV
Dynamic Load Peak Deviation
FEATURES and OPTIONS
Remote On/Off Control
“N” suffix:
same as above
200
Negative Logic, ON state
Negative Logic, OFF state
Control Current
ON = Pin grounded or external voltage
OFF = Pin open or external voltage
open collector/drain
-0.1
2.5
0.8
15
2
V
V
mA
1
www.murata-ps.com/support
MDC_ULS Series.B27 Page 7 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
FUNCTIONAL SPECIFICATIONS, ULS-5/12-D48 (CONT.)
FEATURES and OPTIONS (cont.)
Remote On/Off Control (cont.)
“P” suffix:
Conditions ➀
Minimum
Typical/Nominal
Maximum
Units
Positive Logic, ON state
Positive Logic, OFF state
Control Current
OUTPUT
Total Output Power
ON = Pin open or external voltage
OFF = Ground pin or external voltage
open collector/drain
3.5
0
15
1
2
V
V
mA
1
60
5
0
60.6
W
Voltage
Nominal Output Voltage ➂
15
No trim
At 50ꢀ load
4.95
-1
-10
6
5.05
1
10
Vdc
ꢀ of Vset
Settling Accuracy
Output Voltage Range ➇
Overvoltage Protection
Remote Sense Compensation
Current
User-adjustable
Via magnetic feedback
6.5
10
7.2
Vdc
ꢀ
18
Of Vset
Output Current Range
Minimum Load
Current Limit Inception
0
12
No minimum load
16
12
19
A
A
13
98ꢀ of Vnom., after warm up
14
Short Circuit ➄
Hiccup technique, autorecovery within 1ꢀ
of Vout
Short Circuit Current
0.5
1
A
Short Circuit Duration
(remove short for recovery)
Short circuit protection method
Regulation
Output shorted to ground, no damage
Hiccup current limiting
Continuous
Vin=min. to max., Vout=nom., nom load
Iout=min. to max
0.125
0.25
50
V
V
Line Regulation ➆
Load Regulation ➆
Ripple and Noise
5 Hz- 20 MHz BW
At all outputs
100
mV pk-pk
ꢀ of Vout./°C
Temperature Coefficient
0.02
Maximum Capacitive Loading
(10% ceramic, 90% Oscon)
Low ESR, .02 ohms max (resistive load)
220
1000
ꢁF
MECHANICAL (Through Hole Models)
Outline Dimensions
(Please refer to outline drawing)
Weight
Cxx case
WxLxH
1.3x0.9x0.4
33x22.9x10.2
0.58
Inches
mm
Ounces
Grams
Inches
mm
16.4
Through Hole Pin Diameter
.062 & .04
1.575 & 1.016
Gold-plated copper
alloy with nickel
underplate
50
Through Hole Pin Material
TH Pin Plating Metal and Thickness
Nickel subplate
Gold overplate
μ-inches
μ-inches
5
ENVIRONMENTAL
No derating, full power, 200 LFM,
no condensation
11
Operating Ambient Temperature Range
-40
85
°C
Storage Temperature
Operating Case Temp
Vin = Zero (no power)
No derating required
Measured at hotspot
-55
-40
110
125
120
130
°C
°C
°C
Thermal Protection/Shutdown
Electromagnetic Interference
Conducted, EN55022/CISPR22
Radiated, EN55022/CISPR22
RoHS rating
115
External filter is required
A
A
Class
Class
RoHS-6
www.murata-ps.com/support
MDC_ULS Series.B27 Page 8 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
TYPICAL PERFORMANCE DATA, ULS-5/12-D48
Efficiency and Power Dissipation @ 25°C
Maximum Current Temperature Derating at Sea Level
(VIN = 48V, airflow is from Vin to Vout)
13
12
11
10
9
100
95
12
11
10
9
90
Natural convection
85
VIN = 75V
VIN = 48V
VIN = 36V
80
8
75
7
70
65
60
6
5
8
4
Power Dissipation
55
50
3
(Vin = 48V)
7
2
30
35
40
45
50
55
60
65
70
75
80
85
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
Ambient Temperature (ºC)
Load Current (Amps)
Enable Start-up (Vin=48V, Iout=12A, Ta=+25°C) Trace 2=Output, Trace 4= Enable.
Enable Start-up (Vin=48V, Iout=0A, Ta=+25°C) Trace 2=Output, Trace 4= Enable.
Enable Start-up (Vin=48V, Iout=12A, Cload=1000uF, Ta=+25°C)
Trace 2=Output, Trace 4= Enable.
www.murata-ps.com/support
MDC_ULS Series.B27 Page 9 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
TYPICAL PERFORMANCE DATA, ULS-5/12-D48 (CONT.)
Output and Ripple Noise (Vin=48V, Iout=12A, 1uF Ceramic and 10uF tantalum capacitors) Output and Ripple Noise (Vin=48V, Iout=0A, 1uF Ceramic and 10uF tantalum capacitors)
Transient Response (Vin=48V, Iout=50-75-50ꢀ of Imax)
(Recovery time=9.6uS)
Transient Response (Vin=48V, Iout=50-75-50ꢀ of Imax)
(Recovery time=10uS)
Transient Response (Vin=48V, Iout=50-75-50ꢀ of Imax)
Thermal image with hot spot at full load with 85 °C ambient; air is flowing at 400LFM. Air
if flowing across the converter from +V to -V at 48V input. Identifiable and recommended
value to be verified in application. (Q2, max temp=120 °C/IPC9592 guidelines)
www.murata-ps.com/support
MDC_ULS Series.B27 Page 10 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
FUNCTIONAL SPECIFICATIONS, ULS-12/5-D48
ABSOLUTE MAXIMUM RATINGS
Input Voltage, Continuous
Minimum
Typical/Nominal
Maximum
Units
Vdc
Conditions ➀
Full power operation
80
Operating or non-operating, tested:
100 mS max. duration
Input Voltage, Transient
100
Vdc
Isolation Voltage
Input to output
None, install external fuse
Power on, referred to -Vin
2250
Vdc
Vdc
Vdc
W
Input Reverse Polarity
On/Off Remote Control
Output Power
None
0
0
15
60.6
Current-limited, no damage,
short-circuit protected
Vin = Zero (no power)
Output Current
0
5
A
Storage Temperature Range
-55
125
°C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other
than those listed in the Performance/Functional Specifications Table is not implied or recommended.
INPUT
Operating voltage range
Recommended External Fuse
Start-up threshold, turn on
Undervoltage shutdown, turn off
Overvoltage protection
Reverse Polarity Protection
Internal Filter Type
36
48
75
4
35.5
33.5
Vdc
A
Vdc
Vdc
Vdc
Vdc
Fast blow
Rising input voltage
Falling input voltage
33
31
34.5
32.5
NA
12
None, install external fuse
None
Capacitance
Input current
Full Load Conditions
Low Line
Vin = nominal
Vin = minimum
1.37
1.83
1.43
1.89
A
A
Inrush Transient
0.05
100
50
15
A2-Sec.
mA
mA
Output in Short Circuit
No Load input current
Shut-Down Mode Input Current
200
150
25
Iout = minimum, unit=ON
mA
no filtering
Measured at input with specified filter
150
15
200
30
mAp-p
mAp-p
Reflected (back) ripple current ➁
Reflected (back) ripple current ➁
The converter will
start if the external
load pre-bias does
not exceed Vnom
Pre-biased startup
External output voltage < Vset
GENERAL and SAFETY
Efficiency
Vin=48V, full load
Vin=Min
88
89
91
90
ꢀ
ꢀ
Isolation
Isolation Voltage, input to output
Insulation Safety Rating
Isolation Resistance
Isolation Capacitance
2250
Vdc
basic
100
1000
MΩ
pF
UL-60950-1, CSA-C22.2 No.60950-1,
IEC/EN60950-1, 2nd Edition
Per MIL-HDBK-217F, ground benign,
Tambient=+40°C
Safety (meets the following requirements)
Calculated MTBF
Yes
TBD
3200
Hours x 103
Hours x 103
Per Telcordia SR332, issue 1, class 3, ground
fixed, Tambient=+40°C
Calculated MTBF ➃
DYNAMIC CHARACTERISTICS
19
Fixed Switching Frequency
Startup Time
Startup Time
470
520
570
30
30
KHz
mS
mS
Power on, Vout regulated
Remote ON to Vout regulated
50-75-50ꢀ load step, settling time to within
1ꢀ of Vout.
Dynamic Load Response
25
50
μSec
mV
Dynamic Load Peak Deviation
FEATURES and OPTIONS
Remote On/Off Control
“N” suffix:
same as above
180
240
Negative Logic, ON state
Negative Logic, OFF state
Control Current
ON = Pin grounded or external voltage
OFF = Pin open or external voltage
open collector/drain
-0.1
2.5
0.8
15
2
V
V
mA
1
www.murata-ps.com/support
MDC_ULS Series.B27 Page 11 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
FUNCTIONAL SPECIFICATIONS, ULS-12/5-D48 (CONT.)
FEATURES and OPTIONS (cont.)
Remote On/Off Control (cont.)
“P” suffix:
Conditions ➀
Minimum
Typical/Nominal
Maximum
Units
Positive Logic, ON state
Positive Logic, OFF state
Control Current
ON = Pin open or external voltage
OFF = Ground pin or external voltage
open collector/drain
3.5
0
15
1
2
V
V
mA
1
OUTPUT
Total Output Power
Voltage
Nominal Output Voltage ➂
Settling Accuracy
Output Voltage Range ➇
Overvoltage Protection
Remote Sense Compensation
Current
0
60
12
60.6
W
15
No trim
At 50ꢀ load
User-adjustable
Via magnetic feedback
11.88
-1
-10
12.12
1
10
Vdc
ꢀ of Vset
13.3
14.5
10
18
Vdc
ꢀ
18
Of Vset
Output Current Range
Minimum Load
Current Limit Inception
0
5
No minimum load
6.8
5
8
A
A
13
98ꢀ of Vnom., after warm up
5.5
Short Circuit ➄
Hiccup technique, autorecovery within 1ꢀ
of Vout
Short Circuit Current
0.6
A
Short Circuit Duration
(remove short for recovery)
Short circuit protection method
Regulation
Output shorted to ground, no damage
Hiccup current limiting
Continuous
Vin=min. to max., Vout=nom., nom load
Iout=min. to max
0.125
0.25
80
V
V
Line Regulation ➆
Load Regulation ➆
Ripple and Noise
5 Hz- 20 MHz BW
At all outputs
120
mV pk-pk
ꢀ of Vout./°C
Temperature Coefficient
0.02
Maximum Capacitive Loading
(10% ceramic, 90% Oscon)
Maximum Capacitive Loading
MECHANICAL (Through Hole Models)
Outline Dimensions
Low ESR, .02 ohms max (resistive load)
loads: CC mode
1000
ꢁF
ꢁF
Cxx case
WxLxH
1.3x0.9x0.4
33x22.9x10.2
0.58
Inches
mm
Ounces
Grams
Inches
mm
(Please refer to outline drawing)
Weight
16.4
Through Hole Pin Diameter
.062 & .04
1.575 & 1.016
Gold-plated copper
alloy with nickel
underplate
50
Through Hole Pin Material
TH Pin Plating Metal and Thickness
Nickel subplate
Gold overplate
μ-inches
μ-inches
5
ENVIRONMENTAL
No derating, full power, 200 LFM,
no condensation
11
Operating Ambient Temperature Range
-40
85
°C
Storage Temperature
Operating Case Temp
Vin = Zero (no power)
No derating required
Measured at hotspot
-55
-40
115
125
105
130
°C
°C
°C
Thermal Protection/Shutdown
Electromagnetic Interference
Conducted, EN55022/CISPR22
Radiated, EN55022/CISPR22
RoHS rating
125
External filter is required
B
B
Class
Class
RoHS-6
www.murata-ps.com/support
MDC_ULS Series.B27 Page 12 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
Performance Specification Notes
➀
All specifications are typical unless noted. Ambient temperature =
+25°Celsius, VIN is nominal, output current is maximum rated nominal.
External output capacitance is 1 μF multilayer ceramic paralleled with
10 μF electrolytic. All caps are low ESR. These capacitors are necessary for
our test equipment and may not be needed in your application.
Testing must be kept short enough that the converter does not appreciably
heat up during testing. For extended testing, use plenty of airflow. See
Derating Curves for temperature performance. All models are stable and
regulate within spec without external cacacitance.
➇
➈
Do not exceed maximum power ratings, Sense limits or output overvoltage
when adjusting output trim values.
At zero output current, Vout may contain components which slightly
exceed the ripple and noise specifications.
➉
11
Output overload protection is non-latching. When the output overload
is removed, the output will automatically recover.
All models are fully operational and meet published specifications,
including “cold start” at –40°C.
➁
➂
Input Ripple Current is tested and specified over a 5-20 MHz bandwidth
and uses a special set of external filters only for the Ripple Current speci-
fications. Input filtering is CIN = 33 μF, CBUS = 220 μF, LBUS = 12 μH. Use
capacitor rated voltages which are twice the maximum expected voltage.
Capacitors must accept high speed AC switching currents.
12
The converter will shut off if the input falls below the undervoltage thresh-
old. It will not restart until the input exceeds the Input Start Up Voltage.
13
14
Short circuit shutdown begins when the output voltage degrades approxi-
mately 2ꢀ from the selected setting.
Output noise may be further reduced by installing an external filter. See
the Application Notes. Use only as much output filtering as needed and no
more. Larger caps (especially low-ESR ceramic types) may slow transient
response or degrade dynamic performance. Thoroughly test your applica-
tion with all components installed.
Note that Maximum Current Derating Curves indicate an average current
at nominal input voltage. At higher temperatures and/or lower airflow, the
converter will tolerate brief full current outputs if the average RMS current
over time does not exceed the Derating curve. All Derating curves are
presented at sea level altitude. Be aware of reduced power dissipation
with increasing density altitude.
15
To avoid damage or unplanned shutdown, do not sink appreciable reverse
output current.
➃
➄
Mean Time Before Failure (MTBF) is calculated using the Telcordia
(Belcore) SR-332 Method 1, Case 3, Issue 1, ground fixed conditions. Oper-
ating temperature = +30°C, full output load, natural air convection.
16
17
If reverse polarity is accidentally applied to the input, always connect an
external fast blow input fuse in series with the +VIN input.
Although extremely unlikely, failure of the internal components of this
product may expose external application circuits to dangerous voltages,
currents, temperatures or power levels. Please thoroughly verify all appli-
cations before committing them to service. Be sure to include appropri-
ately rated FUSES (see specifications and Application Notes) to reduce the
risk of failure.
The output may be shorted to ground indefinitely with no damage. The
Output Short Circuit Current shown in the specifications is an average con-
sisting of very short bursts of full rated current to test whether the output
circuit can be repowered.
➅
➆
The On/Off Control is normally driven from a switch or relay. An open
collector/open drain transistor may be used in saturation and cut-off
(pinch-off) modes. External logic may also be used if voltage levels are
fully compliant to the specifications.
18
19
If Sense is not wired to an external load, connect sense pins to their
respective Vout pins. Do not leave sense unconnected.
All models use fixed switching frequencies.
Regulation specifications describe the deviation as the input line voltage
or output load current is varied from a nominal midpoint value to either
extreme (50ꢀ load).
www.murata-ps.com/support
MDC_ULS Series.B27 Page 13 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
TYPICAL PERFORMANCE DATA, ULS-12/5-D48
Efficiency and Power Dissipation vs. Line Voltage and Load Current @ 25°C
Maximum Current Temperature Derating at Sea Level
(VIN = 48V, airflow is from Vin to Vout)
6
5
4
3
2
1
0
100
95
90
85
80
75
70
65
60
55
50
12
11
10
9
Natural convection
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
2.0 m/s (400 LFM)
8
VIN = 75V
VIN = 48V
VIN = 36V
7
6
5
4
Power Dissipation
(Vin = 48V)
3
2
5.00
30
35
40
45
50
55
60
65
70
75
80
85
0.50
0.95
1.40
1.85
2.30
2.75
3.20
3.65
4.10
4.55
Ambient Temperature (ºC)
Load Current (Amps)
Enable Start-up (Vin=48V, Iout=5A, Ta=+25°C) Trace 2=Output, Trace 4= Enable.
Enable Start-up (Vin=48V, Iout=0A, Ta=+25°C) Trace 2=Output, Trace 4= Enable.
Enable Start-up (Vin=48V, Iout=5A, Cload=1000uF Ta=+25°C) Trace 2=Output,
Trace 4= Enable.
www.murata-ps.com/support
MDC_ULS Series.B27 Page 14 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
TYPICAL PERFORMANCE DATA, ULS-12/5-D48 (CONT.)
Output and Ripple Noise (Vin=48V, Iout=0A, 1uF Ceramic and 10uF tantalum capacitors) Output and Ripple Noise (Vin=48V, Iout=5A, 1uF Ceramic and 10uF tantalum capacitors)
Transient Response (Vin=48V, Iout=50-75-50ꢀ of Imax)
(Delta=170mv, Recovery time=16uS)
Transient Response (Vin=48V, Iout=50-75-50ꢀ of Imax)
(-Delta=183.12mV, Recovery time=18.2uS)
Transient Response (Vin=48V, Iout=50-75-50ꢀ of Imax)
Thermal image with hot spot at full load with 85 °C ambient; air is flowing at 400LFM. Air
if flowing across the converter from -V to +V at 48V input. Identifiable and recommended
value to be verified in application. (Q2, max temp=120 °C/IPC9592 guidelines)
www.murata-ps.com/support
MDC_ULS Series.B27 Page 15 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
MECHANICAL SPECIFICATIONS, THROUGH-HOLE MOUNT
TOP VIEW
INPUT/OUTPUT CONNECTIONS P75
Pin
Function
-Vin
Pin
4
Function
-Vout
3
5
–Sense In
Trim
2
1
On/Off Control
+Vin
6
7
+Sense In
+Vout
8
Important! Always connect the sense pins. If they
are not connected to a remote load, wire each
sense pin to its respective voltage output at the
converter pins.
The 0.145-inch pin length is shown. Please refer to
the part number structure for alternate pin lengths.
Pin material: Copper alloy. Plating: Gold over nickel
SIDE VIEW
Please note that some competitive units may use
different pin numbering or alternate outline views;
however, all units are plugin-compatible.
PINS 1-3,5-7:
ij0.040 0.001(1.016 0.025)
1.100 (27.9)
PINS 4,8:
ij0.062 0.001(1.575 0.025)
It is recommended that no parts be placed beneath
the converter
BOTTOM PIN VIEW
1.30 (33.0)
END VIEW
Dimensions are in inches (mm) shown for ref. only.
3
4
5
Third Angle Projection
2
6
7
8
Tolerances (unless otherwise specified):
.XX 0.02 (0.5)
1
.XXX 0.010 (0.25)
Angles 2ꢂ
RECOMMENDED FOOTPRINT
(VIEW THROUGH CONVERTER)
Components are shown for reference only
and may vary between units.
TOP VIEW
FINISHED HOLE SIZES
@ PINS 1-3, 6, 5*, 7*
(PER IPC-D-275, LEVEL C)
.048-.062
(PRI)
(SEC)
1.100
[27.94]
3.81
.150
8
1
2
11.7
.46
7.62
.300
7*
6
22.9
.90
C
C
L
L
5*
7.62
.300
3
4
3.81
.150
14.0
.55
.100 MIN
ANNULAR RING
FOR ALL PIN
SHOULDERS
C
L
33
FINISHED HOLE SIZES
@ PINS 4 & 8
(PER IPC-D-275, LEVEL C)
.070-.084
1.30
www.murata-ps.com/support
MDC_ULS Series.B27 Page 16 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
SHIPPING TRAYS AND BOXES, THROUGH-HOLE MOUNT
Anti-static foam
Corner spacer
2 cartons
per box
Each tray is 4 x 8 units
(32 units total per tray)
128 units
per carton
Label
256 units total per box
Corrugated
cardboard box
All materials in contact with the units are anti-static protective.
Dimensions are in inches (mm).
Label
SHIPPING TRAY DIMENSIONS
Material: Low density, closed cell polyethylene anti-static foam
9.84
(250.00)
0.87
(22.00)
0.59
(15.00)
4-C 0.26
(6.5)
Dimensions are in milimeters.
Third Angle Projection
R0.31
(8.00)
Tolerances (unless otherwise specified):
.XX 0.5
.XXX 0.25
Angles 2ꢂ
0.51
(13.00)
1.34
(34.00)
1.97
(50.00)
0.31
(8.00)
www.murata-ps.com/support
MDC_ULS Series.B27 Page 17 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
MECHANICAL SPECIFICATIONS, SURFACE MOUNT (MSL RATING 3).
TOP VIEW
INPUT/OUTPUT CONNECTIONS P75
Pin
Function
-Vin
Pin
4
Function
-Vout
3
5
–Sense In
Trim
2
1
On/Off Control
+Vin
6
7
+Sense In
+Vout
8
Important! Always connect the sense pins. If they
are not connected to a remote load, wire each
sense pin to its respective voltage output at the
converter pins.
Pin material: Copper alloy. Plating: Gold over nickel
SIDE VIEW
Please note that some competitive units may use
different pin numbering or alternate outline views;
however, all units are plugin-compatible.
0.062
(1.575)
1.100
It is recommended that no parts be placed beneath
the converter
1.100 (27.9)
BOTTOM PIN VIEW
1.30 (33.0)
END VIEW
Dimensions are in inches (mm) shown for ref. only.
3
4
5
Third Angle Projection
2
6
7
8
Tolerances (unless otherwise specified):
.XX 0.02 (0.5)
1
.XXX 0.010 (0.25)
Angles 2ꢂ
RECOMMENDED FOOTPRINT
(VIEW THROUGH CONVERTER)
Components are shown for reference only
and may vary between units.
TOP VIEW
(PRI)
(SEC)
27.94
1.100
3.81
.150
8
1
2
11.7
.46
7.62
.300
7*
6
22.9
.90
C
C
L
L
5*
7.62
.300
3
4
3.81
.150
14.0
.55
.070 MIN PAD
C
L
(6 OR 8 PLACES
AS REQUIRED)
33
1.30
www.murata-ps.com/support
MDC_ULS Series.B27 Page 18 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
TAPE AND REEL INFORMATION
Feed (Unwind)
Direction ----
[2.0]
0.079
6-8mm
PICK-UP
NOZZLE
Pin #1
Round
Holes
1.75
.069
[18.92]
0.745
44.00
1.732
32.00
1.260
PITCH
Oblong
Holes
Top Cover Tape
[9.65]
.38 REF
330.20
13.00
TAPE AND REEL
(200 UNITS
PER REEL)
101.60
4.00
CORE
13.00
.512
44.0
1.73
Dimensions are in inches (mm shown for ref. only).
REF
Third Angle Projection
Tolerances (unless otherwise specified):
.XX 0.02 (0.5)
.XXX 0.010 (0.25)
Angles 1ꢂ
Components are shown for reference only.
www.murata-ps.com/support
MDC_ULS Series.B27 Page 19 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
TECHNICAL NOTES
Input Fusing
I/O Filtering, Input Ripple Current, and Output Noise
Certain applications and/or safety agencies may require the installation of
fuses at the inputs of power conversion components. Fuses should also be
used if the possibility of sustained, non-current-limited, input-voltage polarity
reversals exists. For DATEL ULS series DC/DC converters, we recommend the
use of a fast blow fuse, installed in the ungrounded input supply line with a
typical value about twice the maximum input current, calculated at low line
with the converter’s minimum efficiency.
All models in the ULS Series are tested/specified for input reflected ripple
current and output noise using the specified external input/output components/
circuits and layout as shown in the following two figures. External input capaci-
tors (CIN in Figure 2) serve primarily as energy-storage elements, minimiz-
ing line voltage variations caused by transient IR drops in conductors from
backplane to the DC/DC. Input caps should be selected for bulk capacitance
(at appropriate frequencies), low ESR, and high rms-ripple-current ratings. The
switching nature of DC/DC converters requires that dc voltage sources have
low ac impedance as highly inductive source impedance can affect system sta-
bility. In Figure 2, CBUS and LBUS simulate a typical dc voltage bus. Your specific
system configuration may necessitate additional considerations.
All relevant national and international safety standards and regulations must
be observed by the installer. For system safety agency approvals, the convert-
ers must be installed in compliance with the requirements of the end- use
safety standard.
TO
Input Reverse-Polarity Protection
CURRENT
PROBE
OSCILLOSCOPE
If the input voltage polarity is accidentally reversed, an internal diode will
become forward biased and likely draw excessive current from the power
source. If this source is not current limited or the circuit appropriately fused, it
could cause permanent damage to the converter.
+VIN
–VIN
LBUS
+
V
IN
CBUS
CIN
–
Input Under-Voltage Shutdown and Start-Up Threshold
Under normal start-up conditions, devices will not begin to regulate properly
until the ramping-up input voltage exceeds the Start-Up Threshold Voltage.
Once operating, devices will not turn off until the input voltage drops below the
Under-Voltage Shutdown limit. Subsequent re-start will not occur until the input
is brought back up to the Start-Up Threshold. This built in hysteresis prevents
any unstable on/off situations from occurring at a single input voltage.
C
IN = 33μF, ESR < 700mΩ @ 100kHz
BUS = 220μF, ESR < 100mΩ @ 100kHz
C
L
BUS = 12μH
Figure 2. Measuring Input Ripple Current
In critical applications, output ripple/noise (also referred to as periodic and
random deviations or PARD) may be reduced below specified limits using filter-
ing techniques, the simplest of which is the installation of additional external
output capacitors. They function as true filter elements and should be selected
for bulk capacitance, low ESR and appropriate frequency response.
Start-Up Time
The VIN to VOUT Start-Up Time is the time interval between the point at which
the ramping input voltage crosses the Start-Up Threshold and the fully loaded
output voltage enters and remains within its specified accuracy band. Actual
measured times will vary with input source impedance, external input capaci-
tance, and the slew rate and final value of the input voltage as it appears at the
converter. The ULS Series implements a soft start circuit to limit the duty cycle
of its PWM controller at power up, thereby limiting the input inrush current.
All external capacitors should have appropriate voltage ratings and be
located as close to the converter as possible. Temperature variations for all
relevant parameters should also be taken carefully into consideration. The most
effective combination of external I/O capacitors will be a function of line voltage
and source impedance, as well as particular load and layout conditions.
The On/Off Control to VOUT start-up time assumes the converter has its
nominal input voltage applied but is turned off via the On/Off Control pin. The
specification defines the interval between the point at which the converter is
turned on (released) and the fully loaded output voltage enters and remains
within its specified accuracy band. Similar to the VIN to VOUT start-up, the On/Off
Control to VOUT start-up time is also governed by the internal soft start circuitry
and external load capacitance. The difference in start up time from VIN to VOUT
and from On/Off Control to VOUT is therefore insignificant.
+SENSE
+VOUT
RLOAD
SCOPE
C1
C2
–VOUT
Input Source Impedance
–SENSE
The input of ULS converters must be driven from a low ac-impedance source.
The DC/DC’s performance and stability can be compromised by the use of
highly inductive source impedances. The input circuit shown in Figure 2 is a
practical solution that can be used to minimize the effects of inductance in the
input traces. For optimum performance, components should be mounted close
to the DC/DC converter.
C1 = 1μF
C2 = 10μF
LOAD 2-3 INCHES (51-76mm) FROM MODULE
Figure 3. Measuring Output Ripple/Noise (PARD)
www.murata-ps.com/support
MDC_ULS Series.B27 Page 20 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
Floating Outputs
Remote Sense
Since these are isolated DC/DC converters, their outputs are “floating” with
respect to their input. Designers will normally use the –Output as the ground/
Note: The Sense and VOUT lines are internally connected through low-value
resistors. Nevertheless, if the sense function is not used for remote regulation
return of the load circuit. You can however, use the +Output as ground/return to the user should connect the +Sense to +VOUT and –Sense to –VOUT at the DC/
effectively reverse the output polarity.
DC converter pins. ULS series converters employ a sense feature to provide
point of use regulation, thereby overcoming moderate IR drops in PCB conduc-
tors or cabling. The remote sense lines carry very little current and therefore
require minimal cross-sectional-area conductors. The sense lines, which are
capacitively coupled to their respective output lines, are used by the feedback
control-loop to regulate the output. As such, they are not low impedance points
and must be treated with care in layouts and cabling. Sense lines on a PCB
should be run adjacent to dc signals, preferably ground.
Minimum Output Loading Requirements
ULS converters employ a synchronous-rectifier design topology and all models
regulate within spec and are stable under no-load to full load conditions.
Operation under no-load conditions however might slightly increase the output
ripple and noise.
Thermal Shutdown
The ULS converters are equipped with thermal-shutdown circuitry. If environ-
mental conditions cause the temperature of the DC/DC converter to rise above
the designed operating temperature, a precision temperature sensor will power
down the unit. When the internal temperature decreases below the threshold
of the temperature sensor, the unit will self start. See Performance/Functional
Specifications.
[VOUT(+)-VOUT(–)] – [Sense(+)-Sense(–)] d 10ꢀVOUT
In cables and discrete wiring applications, twisted pair or other techniques
should be used. Output over-voltage protection is monitored at the output volt-
age pin, not the Sense pin. Therefore, excessive voltage differences between
VOUT and Sense in conjunction with trim adjustment of the output voltage can
cause the over-voltage protection circuitry to activate (see Performance Speci-
fications for over-voltage limits). Power derating is based on maximum output
current and voltage at the converter’s output pins. Use of trim and sense func-
tions can cause output voltages to increase, thereby increasing output power
beyond the converter’s specified rating, or cause output voltages to climb into
the output over-voltage region. Therefore, the designer must ensure:
Output Over-Voltage Protection
The ULS output voltage is monitored for an over-voltage condition using a com-
parator. The signal is optically coupled to the primary side and if the output volt-
age rises to a level which could be damaging to the load, the sensing circuitry
will power down the PWM controller causing the output voltage to decrease.
Following a time-out period the PWM will restart, causing the output voltage
to ramp to its appropriate value. If the fault condition persists, and the output
voltage again climbs to excessive levels, the over-voltage circuitry will initiate
another shutdown cycle. This on/off cycling is referred to as “hiccup” mode.
(VOUT at pins) x (IOUT) d rated output power
Contact and PCB resistance
losses due to IR drops
+VOUT
–VIN
Current Limiting
IOUT
As soon as the output current increases to approximately 130ꢀ of its rated
value, the DC/DC converter will go into a current-limiting mode. In this condi-
tion, the output voltage will decrease proportionately with increases in output
current, thereby maintaining somewhat constant power dissipation. This is
commonly referred to as power limiting. Current limit inception is defined
as the point at which the full-power output voltage falls below the specified
tolerance. See Performance/Functional Specifications. If the load current, being
drawn from the converter, is significant enough, the unit will go into a short
circuit condition as described below.
+SENSE
Sense Current
ON/OFF
CONTROL
TRIM
–SENSE
–VOUT
LOAD
Sense Return
IOUT Return
+VIN
Contact and PCB resistance
losses due to IR drops
Short Circuit Condition
Figure 4. Remote Sense Circuit Configuration
When a converter is in current-limit mode, the output voltage will drop as the
output current demand increases. If the output voltage drops too low, the mag-
netically coupled voltage used to develop primary side voltages will also drop,
thereby shutting down the PWM controller. Following a time-out period, the
PWM will restart causing the output voltage to begin ramping to their appropri-
ate value. If the short-circuit condition persists, another shutdown cycle will be
initiated. This on/off cycling is referred to as “hiccup” mode. The hiccup cycling
reduces the average output current, thereby preventing internal temperatures
from rising to excessive levels. The ULS Series is capable of enduring an indefi-
nite short circuit output condition.
On/Off Control
The input-side, remote On/Off Control function can be ordered to operate with
either logic type:
Positive ("P" suffix) logic models are enabled when the on/off pin is left
open (or is pulled high, applying +3.5V to +15V with respect to –Input) as per
Figure 5. Positive-logic devices are disabled when the on/off pin is pulled low
(0 to 1V with respect to –Input).
Negative (“N” suffix) logic devices are off when pin is left open (or pulled
high, applying +2.5V to +15V), and on when pin is pulled low (–0.1 to +0.8V)
with respect to –Input as shown in Figure 5.
www.murata-ps.com/support
MDC_ULS Series.B27 Page 21 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
Dynamic control of the remote on/off function is best accomplished with a
mechanical relay or an open-collector/open-drain drive circuit (optically isolated
if appropriate). The drive circuit should be able to sink appropriate current (see
Performance Specifications) when activated and withstand appropriate voltage
when deactivated. Applying an external voltage to pin 2 when no input power is
applied to the converter can cause permanent damage to the converter.
+VIN
+Vcc
13V CIRCUIT
ON/OFF
CONTROL
5V CIRCUIT
–VIN
Figure 5. Driving the Negative Logic On/Off Control Pin
(simplified circuit)
OUTPUT VOLTAGE ADJUSTMENT
Trim Equations
Trim Down
5.11
+VOUT
–VIN
RT DOWN (k:) =
– 10.22
+SENSE
Δ
VOUT – VNOM
Where Δꢀ ꢀ_ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ _
ON/OFF
CONTROL
TRIM
–SENSE
–VOUT
LOAD
VNOM
RTRIM UP
Trim Up
5.11 × VNOM x (1 + Δ)
1.225 × Δ
5.11
Δ
– 10.22
–
RT UP (k:) =
+VIN
VOUT – VNOM
Where Δꢀ ꢀ_ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ _
Figure 6. Trim Connections To Increase Output Voltages
VNOM
Connect sense to its respective VOUT pin if sense is not used with a remote load.
Note: “Δ” is always a positive value.
“VNOM” is the nominal, rated output voltage.
“VOUT” is the desired, changed output voltage.
+VOUT
–VIN
+SENSE
RTRIM DOWN
ON/OFF
CONTROL
TRIM
–SENSE
–VOUT
LOAD
+VIN
Figure 7. Trim Connections To Decrease Output Voltages
www.murata-ps.com/support
MDC_ULS Series.B27 Page 22 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
Trimming by Using an External Voltage Source
+VOUT
1. The easiest way to trim the output using an external voltage source is to
drive the Trim pin directly from a variable source. The following equation can
be used to calculate the voltage at the Trim pin.
+VIN
External
+SENSE
source
+
–
Vo
ON/OFF
CONTROL
TRIM
–SENSE
–VOUT
LOAD
Vtrim = 2 x 1.225 x
− 1.225
Vonominal
Vo is the output voltage you want; Vonominal is the nominal output voltage;
Vtrim is the voltage that should appear at the trim pin.
–VIN
2. If the purpose of trimming is to compensate voltage drop of power path
from converter to the Load, you may separately connect the sense pin directly
to the load. It’s much easier than real time adjusting trim voltage.
Figure 8. Trimming with an External Source
3. CAUTION: To avoid unplanned power down cycles, do not exceed EITHER
the maximum output voltage OR the maximum output power when setting
the trim. If the output voltage is excessive, the OVP circuit may shut down the
converter. If the maximum power is exceeded, the converter may enter current
limiting. If the power is exceeded for an extended period, the converter may
overheat and encounter overtemperature shut down. Be careful of external
electrical noise. The Trim input is a sensitive input to the converter’s feedback
control loop. Excessive electrical noise may cause instability or oscillation.
Through-hole Soldering Guidelines
SMT Reflow Soldering Guidelines
Murata Power Solutions recommends the TH soldering specifications below when install-
ing these converters. These specifications vary depending on the solder type. Exceeding
The surface-mount reflow solder profile shown below is suitable for SAC305 type lead-
free solders. This graph should be used only as a guideline. Many other factors influence
these specifications may cause damage to the product. Your production environment may the success of SMT reflow soldering. Since your production environment may differ,
please thoroughly review these guidelines with your process engineers.
differ; therefore please thoroughly review these guidelines with your process engineers.
Wave Solder Operations for through-hole mounted
products (THMT)
For Sn/Ag/Cu based solders:
Maximum Preheat Temperature
Maximum Pot Temperature
Maximum Solder Dwell Time
For Sn/Pb based solders:
Maximum Preheat Temperature
Maximum Pot Temperature
Maximum Solder Dwell Time
115° C.
270° C.
7 seconds
105° C.
250° C.
6 seconds
www.murata-ps.com/support
MDC_ULS Series.B27 Page 23 of 24
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
Vertical Wind Tunnel
Murata Power Solutions employs a computer controlled
custom-designed closed loop vertical wind tunnel, infrared
video camera system, and test instrumentation for accurate
airflow and heat dissipation analysis of power products.
The system includes a precision low flow-rate anemometer,
variable speed fan, power supply input and load controls,
temperature gauges, and adjustable heating element.
IR Transparent
optical window
Variable
speed fan
Unit under
test (UUT)
The IR camera monitors the thermal performance of the
Unit Under Test (UUT) under static steady-state conditions. A
special optical port is used which is transparent to infrared
wavelengths.
IR Video
Camera
Both through-hole and surface mount converters are sol-
dered down to a host carrier board for realistic heat absorp-
tion and spreading. Both longitudinal and transverse airflow
studies are possible by rotation of this carrier board since
there are often significant differences in the heat dissipation
in the two airflow directions. The combination of adjustable
airflow, adjustable ambient heat, and adjustable Input/Output
currents and voltages mean that a very wide range of mea-
surement conditions can be studied.
Heating
element
Precision
low-rate
anemometer
3” below UUT
The collimator reduces the amount of turbulence adjacent
to the UUT by minimizing airflow turbulence. Such turbulence
influences the effective heat transfer characteristics and gives
false readings. Excess turbulence removes more heat from
some surfaces and less heat from others, possibly causing
uneven overheating.
Ambient
temperature
sensor
Airflow
collimator
Both sides of the UUT are studied since there are different
thermal gradients on each side. The adjustable heating element and
fan, built-in temperature gauges, and no-contact IR camera mean that
power supplies are tested in real-world conditions.
Figure 9. Vertical Wind Tunnel
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2012 Murata Power Solutions, Inc.
www.murata-ps.com/support
MDC_ULS Series.B27 Page 24 of 24