UNS-5/3-D12D-C [MURATA]

DC-DC Regulated Power Supply Module, ROHS COMPLIANT, DIP-10;
UNS-5/3-D12D-C
型号: UNS-5/3-D12D-C
厂家: muRata    muRata
描述:

DC-DC Regulated Power Supply Module, ROHS COMPLIANT, DIP-10

文件: 总5页 (文件大小:504K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
UNS Series  
Non-Isolated, 3.3V & 5V, 3A DC/DC Converters  
Low cost, high efficiency, wide input voltage range and low output  
noise define DATEL’s new UNS Series of non-isolated, step-down,  
switching DC/DC converters.  
FEATURES  
PRODUCT OVERVIEW  
The 3.3V- and 5V-output devices are, respectively,  
90% and 92% efficient. All models are fully line  
and load regulated and maintain specified accuracy  
over the impressively wide input voltage ranges of  
4.75 to 13.6 Volts for 3.3V outputs and 6 to 16.5  
Volts for 5V outputs. Output ripple and noise are  
typically 50mVp-p.  
coated for protection against moisture and dust.  
nLow cost  
The high efficiency of the UNS Series’ fixed-fre-  
quency (190kHz) switching design eliminates the  
need for thermally conductive potting compound.  
Devices are specified for full-power operation up  
to ambient temperatures of +50°C. With derating,  
they operate up to +70°C. Calculated MTBF (MIL-  
HDBK-217F) is more than 1.6 million hours.  
These simple-to-use power converters have no  
minimum load requirements. They draw 1mA when  
unloaded and a mere 100µA in the standby mode  
(On/Off Control turned off). 3.3V models have an  
output voltage adjustment range of 2.7 to 3.3 Volts.  
5V models are adjustable down to 3.0V.  
nSIP or DIP packaging  
n3.3V (10W) or 5V (15W) outputs  
nWide range inputs:  
4.75-13.6V for 3.3V models  
6-16.5V for 5V models  
UNS devices are fabricated using proven SMT-  
on-pcb construction techniques. The 3.3V and 5V  
devices are both available in either lightweight SIP  
(2" x 0.4" x 0.8") or DIP (2" x 0.8" x 0.4", 600 mil  
spacing between rows) package configurations.  
The DIP option is designated by a "D" suffix added  
to the part number. All models are conformally  
nHigh efficiencies, typically 90-92%  
nLow output noise, 50mVp-p  
nRemote on/off control  
n100µA "standby" input current  
nOutput current limiting  
nEMC compliant  
nHighly reliable, 100% SMT construction  
nConformally coated for harsh environments  
SIMPLIFIED SCHEMATIC  
+VOUT  
+VOUT  
TRIM  
+VIN  
+VIN  
–VIN  
–VIN  
OUTPUT  
RETURN  
OUTPUT  
RETURN  
PWM  
CONTROLLER  
ON/OFF  
CONTROL  
REFERENCE &  
ERROR AMP  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UNS10-15W.B01 Page 1 of 5  
UNS Series  
Non-Isolated, 3.3V & 5V, 3A DC/DC Converters  
PERFORMANCE SPECIFICATIONS AND ORDERING GUIDE  
Output  
Input  
Package  
R/N (mVp-p)  
Regulation (Max.)  
Efficiency  
IIN   
VOUT  
IOUT  
VIN Nom.  
(V)  
Range  
(V)  
(Case/  
Model Family  
UNS-3.3/3-D5  
UNS-3.3/3-D5D  
UNS-5/3-D12  
(V)  
(A)  
(mA)  
Min.  
--  
Typ.  
90%  
90%  
92%  
92%  
Pinout)  
Typ.  
50  
Max.  
100  
100  
100  
100  
Line  
1.0  
1.0  
1.0  
1.0  
Load  
3.3  
3.3  
5
3
3
3
3
3.0  
3.0  
3.0  
3.0  
7.5  
7.5  
12  
4.75-13.6 1/1400  
4.75-13.6 1/1400  
B1, P18  
B2, P18  
B1, P18  
B2, P18  
50  
--  
50  
6-16.5  
6-16.5  
1/1330  
1/1330  
--  
UNS-5/3-D12D  
5
50  
12  
--  
Typical at TA = +25°C under nominal line voltage and full-load conditions, unless otherwise noted.   
"D" suffix indicates DIP package.  
Listed output regulation specifications describe the total change in output voltage as the input (line)  
voltage or output (load) current is varied over its full specified range. Typically, line regulation is  
better than 0.5ꢀ and load regulation is better than 1.0ꢀ. Load regulation applies for 0 to 100ꢀ  
load conditions.  
Ripple/Noise (R/N) measured over a 20MHz bandwidth with a 100µF external input capacitor and  
a 220µF external output capacitor. Additional ouput capacitors will lower R/N. See Technical Notes.  
Nominal line voltage, no-load/full-load conditions.  
PART NUMBER STRUCTURE  
MECHANICAL SPECIFICATIONS  
Case B1 (SIP)  
ꢆꢁꢆꢈ  
ꢄꢆꢁꢊꢇ  
-
/
-
U NS 3.3 3 D5 D  
ꢀꢁꢂꢃ  
ꢄꢅꢆꢁꢆꢆꢇ  
ꢆꢁꢋꢊ  
ꢄꢃꢁꢆꢇ  
Output Configuration:  
Add "D" suffix for optional  
DIP package configuration  
U = Unipolar  
ꢆꢁꢊꢀ  
ꢄꢋꢆꢁꢅꢆꢇ  
Input Voltage Range:  
D5 = 4.75-13.6 Volts (7.5V nominal)  
D12 = 6-16.5 Volts (12V nominal)  
Non-Isolated  
SIP packaging  
   
   
    ꢀꢆ  
Nominal Output Voltage:  
3.3 or 5 Volts  
ꢆꢁꢈꢆ  
ꢄꢃꢁꢌꢋꢇ  
ꢆꢁꢆꢋꢅ  
ꢄꢆꢁꢌꢉꢇ  
Maximum Output Current  
in Amps  
ꢆꢁꢀ  
ꢄꢋꢁꢅ  
ꢆꢁꢀꢈ  
ꢄꢈꢁꢉꢀꢇ  
ꢆꢁꢉꢆꢆ  
ꢄꢀꢆꢁꢀꢌꢇ  
ꢆꢁꢂꢆꢆ  
ꢄꢋꢋꢁꢊꢌꢇ  
ꢆꢁꢉꢆꢆ  
ꢄꢀꢆꢁꢀꢌꢇ  
ꢆꢁꢆꢃ  
ꢄꢀꢁꢊꢅꢇ  
Important: Do not include the "A" suffix when ordering.  
 %1ꢁ 3    
ꢆꢁꢀꢆꢆ ꢄꢋꢁꢅꢉꢇ  
 %1ꢁ 3    
ꢆꢁꢀꢆꢆ ꢄꢋꢁꢅꢉꢇ  
TEMPERATURE DERATING  
Case B2 (DIP)  
ꢀꢁꢀꢅ  
ꢄꢀꢁꢋꢇ  
20  
ꢂꢁꢌꢊ  
ꢄꢆꢀꢁꢀꢀꢇ  
ꢀꢁꢈꢋ  
ꢄꢊꢁꢀꢇ  
18  
ꢀꢁꢀꢈꢆ  
ꢄꢀꢁꢉꢃꢇ  
16  
UNS-5/3-D12  
14  
12  
ꢀꢁꢉꢀ  
ꢀꢁꢋꢂ  
ꢄꢂꢆꢁꢈꢃ  
ꢄꢈꢀꢁꢆꢀꢇ  
   
   
    ꢂꢀ  
UNS-3.3/3-D5  
10  
ꢀꢁꢂꢅ  
ꢄꢅꢁꢃꢂꢇ  
ꢀꢁꢂꢀ  
ꢄꢈꢁꢉꢅꢇ  
8
6
4
2
0
ꢀꢁꢂꢃ  
ꢄꢅꢁꢆꢇ  
34!.$/&&  
ꢀꢁꢃꢀꢀ  
ꢄꢂꢀꢁꢂꢉꢇ  
ꢀꢁꢌꢀꢀ  
ꢄꢈꢈꢁꢋꢉꢇ  
ꢀꢁꢃꢀꢀ  
ꢄꢂꢀꢁꢂꢉꢇ  
 %1ꢁ 3    
ꢀꢁꢂꢀꢀ ꢄꢈꢁꢆꢃꢇ  
 %1ꢁ 3    
ꢀꢁꢂꢀꢀ ꢄꢈꢁꢆꢃꢇ  
ꢀꢁꢃꢀ  
ꢄꢂꢀꢁꢂꢉꢇ  
 ./ #/..%#4)/.ꢁ &/2 -%#(!.)#!, 34!"),)49 /.,9ꢁ  
$)-%.3)/.3 !2% ). ).#(%3 ꢄ--ꢇ  
–10  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
INPUT/OUTPUT CONNECTIONS  
Ambient Temperature (°C)  
Pin  
1
Function P18  
+Input  
Pin  
6
Function P18  
Trim  
Note: Derating curves apply to both SIP and DIP package configurations  
2
+Input  
7
Output Rtn.  
Output Rtn.  
+Output  
3
-Input  
8
4
-Input  
9
5
On/Off Control  
10  
+Output  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UNS10-15W.B01 Page 2 of 5  
UNS Series  
Non-Isolated, 3.3V & 5V, 3A DC/DC Converters  
Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted.   
T E C H N I C A L N O T E S  
Input  
Input and Output Capacitors  
Input Voltage Range:  
"D5" and "D5D" Models  
4.75-13.6 Volts (7.5V nominal)  
6-16.5 Volts (12V nominal)  
Though UNS Series, non-isolated, DC/DC converters have on-board input  
and output capacitors (CIN = 6.8µF, COUT = 6.8µF), the majority of applica-  
tions will require the installation of additional external I/O capacitance.  
"D12" and "D12D" Models  
Input Current  
See Ordering Guide  
Input Filter Type  
Capacitive  
The total input capacitance functions as a true energy-storage element, and  
its optimal value will vary as a function of line voltage. The selected external  
input capacitor should have both low ESR and low ESL because, as the  
power converter’s input FET switch cycles on and off, the input capacitance  
must have the ability to instantaneously supply pulses of relatively high cur-  
rent.  
Overvoltage Protection  
Reverse-Polarity Protection  
On/Off Control (Pin 5) ꢀ  
Output  
None  
None  
TTL high (or open) = on, low = off  
VOUT Accuracy  
5ꢀ, maximum  
Temperature Coefficient  
Ripple/Noise (20MHz bandwidth)   
Line/Load Regulation   
Efficiency  
0.01ꢀ per °C  
Rather than install a large, expensive, on-board capacitor that addresses  
all possible input-voltage and output-load conditions, DATEL has chosen to  
leave out the bulk of the input capacitance so that users may select a cost-  
effective component appropriate to their own application. We use a low-ESR  
100µF external input capacitor during production testing.  
See Ordering Guide  
See Ordering Guide  
See Ordering Guide  
Auto-recovery  
Current Limiting   
Dynamic Characteristics  
Foldback Autorecovery – models with the “A” suffix only  
For “A” suffix models only, as output current exceeds the rated limit, cur-  
rent will be sharply reduced using the foldback current limit technique. As  
current is further reduced to a low value, the converter will automatically  
recover normal operation and rated output voltage.  
Transient Response (50ꢀ load step)  
Switching Frequency  
200µsec max. to 2ꢀ of final value  
190kHz  
Environmental  
Operating Temperature:  
Without Derating  
The exact current where autorecovery occurs is dependent on the reac-  
tance of the output load and whether the output load has any “constant  
current” characteristics at start up. On “A” suffix models, some types of  
heavy “constant current” loads may fail to start up properly. This can be  
offset by adding required external capacitance (see below). Normal resistive  
loads will autorecover near the rated full current limit.  
–10 to +50°C  
With Derating  
to +70°C (See Derating Curve)  
Storage Temperature  
–25 to +85°C  
Physical  
Dimensions: SIP Models  
DIP Models   
2 x 0.41 x 0.8" (50 x 10.3 x 21mm)  
2 x 0.8 x 0.44" (50 x 21 x 11.3mm)  
Shielding  
None  
100  
80  
60  
40  
20  
0
Case Connection  
Pin Material  
Weight  
None  
Gold-plated phosphor bronze  
0.35 ounces (10 grams)  
UNS Series devices require external input/output capacitors to achieve rated perfor  
mance. Listed specifications assume CIN = 100µF and COUT = 220µF.ꢀ  
See Technical Notes.  
Output Ripple/Noise can be reduced with external capacitors. See Technical Notes.  
UNS Series converters have no minimum-load requirements.  
Current limiting initiates at approximately 5ꢀ above rated load.  
DIP models have a standoff which makes their total above-board height 0.44 inches.  
0
50  
100  
150  
Output Current (%)  
Absolute Maximum Ratings  
Fig. 1 – Current foldback in “A” suffix units  
Input Voltage:  
"D5" Models  
"D12" Models  
15 Volts  
18 Volts  
Output Capacitance is Required  
Almost all applications must add external output capacitance to improve  
stability, start-up characteristics and to reduce noise. DATEL recommends  
approximately 330µF as a starting point using low-ESR capacitors such as  
the Sanyo OSCON or Poscap series. Use a capacitor voltage rating twice  
the expected output voltage. Lower capacitance and/or higher ESR can  
cause instability with inductive loads. Higher capacitance can lead to poor  
transient response and sluggish regulation. Mount the capacitor close to  
the converter and keep leads short. You may need to experiment.  
Input Reverse-Polarity Protection  
Output Overvoltage Protection  
Output Current  
None. See Technical Notes.  
None  
Current limited. Devices can  
withstand an output short circuit  
for brief durations only.  
Storage Temperature  
–25 to +85°C  
+300°C  
Lead Temperature (soldering, 10 sec.)  
These are stress ratings. Exposure of devices to any of these conditions may adversely  
affect long-term reliability. Proper operation under conditions other than those listed in the  
Performance/Functional Specifications Table is not implied.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UNS10-15W.B01 Page 3 of 5  
UNS Series  
Non-Isolated, 3.3V & 5V, 3A DC/DC Converters  
UNS 5 and 3.3 Volt Series Specification Revision Notice  
Notice: As of January 2006, all models now inlude an “A” suffix  
marked on the unit to indicate a mandatory change in the PWM. Older  
models without the “A” suffix are now obsolete.  
+OUTPUT  
9, 10  
R1  
In late 2003, all UNS series 5 Volt output DC/DC converters improved some  
specifications and changed the trim values. These same changes were  
applied to 3.3 Volt output converters in January 2006. The new converters  
are designated with a trailing letter “A” in the model number (Example:  
UNS-5/3-D12DA) marked on the unit. This designation is not used in  
the ordering model number – it only appears on the device itself. These  
changes were unavoidable because of obsolescence of the PWM controller.  
Older models without the “A” suffix are no longer available.  
ERROR  
AMP  
RTRIM  
6
RLOAD  
TRIM  
R3  
R2  
1.195V  
7, 8  
OUTPUT  
RETURN  
All specifications are unchanged except the following:  
Figure 2. Output Voltage Trimming  
Specification  
"A" Suffix Models - revised specification  
0.2% typ., 1.0% Max.  
0.2% typ., 1.5% Max.  
0.64mm dia., Tin plated  
0.8 Volts  
5V and 3V Model Trim Values  
Line regulation  
Note that if you have not installed trim resistors to existing circuits, there is  
no change. Also, if you have installed a trim pot (instead of a fixed external  
trim resistor), you may only need to recalibrate the trim pot. The trim pot  
value normally does not need to change. If you do not install trim resistors,  
leave Trim pin 6 unconnected (open).  
Load regulation  
Input/output pins  
Internal reference voltage, Vref  
Overcurrent protection  
Foldback current limiting  
On the trim circuit diagram, Figure 2, use the following revised table:  
Output Trimming  
UNS-3.3/3  
UNS-3.3/3  
UNS-5/3  
UNS-5/3  
Model Number  
5V devices can be trimmed down to 3.0V, and 3.3V devices can be trimmed  
down to 2.7V using a single external trimpot or fixed resistor. The trimpot  
should be connected between +VOUT (pins 9 and 10) and Trim (pin 6) as  
shown in the figure below. The trimpot can be used to determine the value of  
a single fixed resistor which can then be connected between pins 9 and 10  
and 6. Fixed resistors should be metal-film types with relatively low absolute  
TCR’s to ensure stability.  
older models "A" models older models "A" models  
Output Voltage  
Adjustment Range  
2.7 to 3.3V  
68.68KΩ  
39KΩ  
2.7 to 3.3V  
62.51KΩ  
20KΩ  
3.0 to 5.0V  
124.7KΩ  
39KΩ  
3.0 to 5.0V  
106KΩ  
R1 Value  
R2 Value  
R3 Value  
20KΩ  
In order to maximize their efficiency, UNS devices employ high-value resis-  
tors in their voltage feedback loop. Consequently, the external trimpots must  
also be high-resistance devices (1-2 megohms). If the trimpots are acciden-  
tally turned to their 0stops, it will not damage the converters; however, the  
output voltage will be pulled down to an unstable level. Use care not to trim  
the output voltage below the levels indicated in the accompanying table.  
10KΩ  
0Ω (short)  
0.8V  
10KΩ  
0KΩ (short)  
0.8V  
Voltage Refer-  
ence, Vref  
1.195V  
1.195V  
RoHS-Compliance  
RoHS (Reduction of Hazardous Substances) compliance is indicated  
solely by the manufacturing date code. All UNS-5V converters with date  
code “WM” (December 2005) or later are RoHS-compliant. All UNS-3.3V  
converters with date code “VF” (June 2006) or later are RoHS-compliant.  
Non-RoHS converters are no longer available. All RoHS models also include  
the “A” suffix changes.  
“A” Model Trim Equation  
Rtrim = (R1 x R2 (Vout – Vref)) / (R1 x Vref – R2 (Vout – Vref)) – R3  
(R3 = 0Ω for “A” models)  
Finally, please note that the trailing “A” suffix in the model number is not  
used for ordering these converters. Use the standard model numbers  
without the “A” suffix.  
Please note carefully that RoHS units do not include a “-C” suffix.  
Date Codes  
The manufacturing date code is a 2-letter code as follows:  
First letter (year):  
Y:2003, X:2004, W:2005, V:2006, U:2007, T:2008, S:2009, R:2010, Q:2011,  
P:2012, O:2013, N:2014, M:2015  
Second letter (month):  
A:January, B:February, C:March, D:April, E:May, F:June, G:July, H:August, I:  
not used, J:September, K:October, L:November, M:December  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UNS10-15W.B01 Page 4 of 5  
UNS Series  
Non-Isolated, 3.3V & 5V, 3A DC/DC Converters  
The On/Off Control Pin  
disables the converter. Control voltages should be referenced to pins 3 and 4  
(–Input). For best results, use a mechanical relay or open-collector logic.  
For normal operation, pin 5 should be left open. This pin has an internal  
250kpull-up resistor to +5V (or to +VIN if +VIN < 5V). For dynamic control  
of the converters’ on/off functionality, a TTL logic high (+2.4V minimum,  
+5V maximum or +VIN maximum if +VIN < 5V, 100µA max.) applied to pin 5  
enables the converter, and a quasi-TTL logic low (0 to +0.5V, 100µA max.)  
When the converter is turned off, its input "standby" current will be approxi-  
mately 100µA. Applying a voltage that is greater than VIN to the On/Off Con-  
trol pin, or applying any voltage to this pin when no input power is applied to  
the converter, may cause permanent damage to the converter.  
T Y P I C A L P E R F O R M A N C E C U R V E S  
100  
98  
96  
94  
92  
100  
V
IN = 4. 75V  
98  
96  
94  
92  
90  
88  
86  
84  
V
IN = 6V  
90  
88  
86  
84  
V
IN = 12V  
V
IN = 7. 5V  
V
IN = 13. 6V  
V
IN = 16. 5V  
0
0.5  
1.0  
1.5  
2.0  
2.5  
3.0  
0
0.5  
1.0  
1.5  
2.0  
2.5  
3.0  
5V Output Current (Amps)  
3.3V Output Current (Amps)  
Efficiency vs. Output Current and Input Voltage (Model UNS-5/3)  
Efficiency vs. Output Current and Input Voltage (Model UNS-3.3/3)  
USA:  
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com  
Canada: Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com  
UK:  
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356  
France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com  
Germany: München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com  
Japan: Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com  
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com  
Website: www.murata-ps.jp  
www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
China:  
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com  
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com  
notice.  
© 2008 Murata Power Solutions, Inc.  
04/09/08  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UNS10-15W.B01 Page 5 of 5  

相关型号:

UNS1K

Surface Mount Transient Voltage Suppressors
UNSEMI

UNS1K48A

Surface Mount Transient Voltage Suppressors
UNSEMI

UNS1K48CA

Surface Mount Transient Voltage Suppressors
UNSEMI

UNS1K58A

Surface Mount Transient Voltage Suppressors
UNSEMI

UNS1K58CA

Surface Mount Transient Voltage Suppressors
UNSEMI

UNS2-T220

Precision Foil Resistors
RIEDON

UNS2-T2200.53OHMS0.5%3PPM

Fixed Resistor, Metal Foil, 15W, 0.53ohm, 0.5% +/-Tol, -3,3ppm/Cel, 4016
VISHAY

UNS2-T2200.542OHMS0.1%3PPM

Fixed Resistor, Metal Foil, 15W, 0.542ohm, 0.1% +/-Tol, -3,3ppm/Cel, 4016
VISHAY

UNS2-T2200.681OHMS1%3PPM

Fixed Resistor, Metal Foil, 15W, 0.681ohm, 1% +/-Tol, -3,3ppm/Cel, 4016
VISHAY

UNS2-T2200.866OHMS1%3PPM

Fixed Resistor, Metal Foil, 15W, 0.866ohm, 1% +/-Tol, -3,3ppm/Cel, 4016
VISHAY

UNS2-T2201.15KOHMS0.1%3PPM

Fixed Resistor, Metal Foil, 10W, 1150ohm, 0.1% +/-Tol, -3,3ppm/Cel, 4016
VISHAY

UNS2-T2201.37KOHMS0.1%3PPM

Fixed Resistor, Metal Foil, 10W, 1370ohm, 0.1% +/-Tol, -3,3ppm/Cel, 4016
VISHAY