UQQ-24/4-Q12P-C [MURATA]

Wide Input Range Single Output DC/DC Converters; 宽输入范围单输出DC / DC转换器
UQQ-24/4-Q12P-C
型号: UQQ-24/4-Q12P-C
厂家: muRata    muRata
描述:

Wide Input Range Single Output DC/DC Converters
宽输入范围单输出DC / DC转换器

转换器
文件: 总17页 (文件大小:456K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
For applications requiring wide range input, improved electrical and  
thermal perfomance consider Murata Power Solutions’ new UQQ  
Series “Quarter-Brick” DC/DC Converters. They measure just 1.45  
x 2.22 x 0.43 inches (36.8 x 56.4 x 10.92mm) and fit the industry-  
standard footprint.  
Typical unit  
FEATURES  
PRODUCT OVERVIEW  
From an 9-36V or 18-75V input, UQQ’s deliver outputs  
of 3.3V, 5V,12V,15V, or 24V. They employ an inter-  
leaved, synchronous-rectifier topology that exploits  
100% of their duty cycle. They simultaneously achieve  
ultra-high efficiency (to 90%), tight line/load regula-  
tion, low noise, and quick step response.  
The UQQ’s feature set includes high isolation, input  
pi filters, input undervoltage shutdown, output overvolt-  
age protection, current limiting, short-circuit protection  
and thermal shutdown. The standard footprint carries  
on/off control (positive or negative polarity), output trim  
(+10/–20%) and output sense functions.  
RoHS compliant  
Standard quarter-brick package/pinout in  
through-hole version  
Low cost; Low profile, 0.43”(10.92mm)  
9-36V or 18-75V wide range inputs  
Output current: 4 to 25 Amps  
A state of the art, single-board, open-frame  
design with reduced component count, high efficiency,  
low-on-resistance FET’s, and planar magnetics  
embedded in heavy-copper pc boards all contribute to  
impressive thermal derating.  
All UQQ quarter-bricks are designed with full mag-  
netic and optical isolation up to 2250 Volts DC (basic  
insulation).  
Output voltages: 3.3, 5, 12, 15 or 24V  
Interleaved synchronous-rectifier topology  
Ultra high efficiency  
No output reverse conduction  
Outstanding thermal performance  
On/off control, trim & sense functions  
Fully isolated, up to 2250Vdc (48 VIN)  
Output overvoltage protection  
SIMPLIFIED SCHEMATIC  
ꢃ6/54  
Fully I/O protected; Thermal shutdown  
ꢃ3%.3%  
n6/54  
Designed to meet UL/EN/IEC60950-1 safety  
approvals  
ꢃ6).  
n6).  
RoHS hazardous substance compliant  
n3%.3%  
37)4#(  
#/.42/,  
/.ꢁ/&&  
07-  
/04/  
)3/,!4)/.  
2%&%2%.#% ꢀ  
%22/2 !-0  
42)-  
#/.42/,  
#/.42/,,%2  
)NPUT UNDERꢁOVERVOLTAGEꢂ  
CURRENT SENSEꢂ OVER  
TEMPERATURE #OMPARATORS  
)3/,!4)/.  
"!22)%2  
Typical topology is shown.  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 1 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
Performance Specifications and Ordering Guide ~  
PERFORMANCE SPECIFICATIONS AND ORDERING GUIDE  
Output  
Input  
Package  
R/N (mVp-p)  
Regulation  
Line Load  
Efficiency  
VOUT  
(V)  
IOUT  
Power  
VIN Nom. Range IIN, no load IIN, full load  
(Case/  
5
Root Model  
(A) (Watts)  
(Volts)  
(Volts)  
(mA)  
180  
80  
(A)  
Min.  
86%  
86%  
Typ.  
88%  
88%  
Pinout)  
Typ.  
50  
Max.  
80  
UQQ-3.3/25-Q12P-C 3.3  
UQQ-3.3/25-Q48N-C 3.3  
25  
25  
17  
20  
8
82.5  
82.5  
85  
0.05%  
0.05%  
0.05%  
0.05%  
0.05%  
0.05%  
0.05%  
0.05%  
0.125%  
0.2%  
12  
9-36  
7.81  
2.01  
7.83  
2.47  
8.99  
2.3  
C68,P32  
C68,P32  
80  
125  
75  
48  
18-75  
9-36  
UQQ-5/17-Q12P-C  
UQQ-5/20-Q48N-C  
UQQ-12/8-Q12P-C  
UQQ-12/8-Q48N-C  
UQQ-15/7-Q12P-C  
UQQ-24/4-Q12P-C  
5
40  
0.06%  
0.165%  
0.05%  
0.1%  
12  
150  
65  
88.5% 90.5% C68,P32  
82.5% 84.5% C68,P32  
5
100  
96  
100  
40  
140  
75  
48  
18-75  
9-36  
12  
12  
15  
24  
12  
180  
70  
87%  
89%  
C68,P32  
8
96  
95  
150  
100  
170  
48  
18-75  
9-36  
87.5% 89.5% C68,P32  
89% 90.5% C68,P32  
7
105  
96  
56  
0.1%  
12  
250  
120  
9.67  
8.99  
4
125  
0.075%  
12  
10-36  
87.7  
89%  
C68,P32  
1 Typical at TA = +25°C under nominal line voltage and full-load conditions. All models are  
specified with an external 1μF multi-layer ceramic and 10μF capacitors across their output pins  
and 100μF external input capacitor.  
2 Ripple/Noise (R/N) measured over a 20MHz bandwidth.  
3 Devices have no minimum-load requirements and will regulate under no-load conditions.  
Regulation specifications describe the output voltage deviation as the line voltage or load is  
varied from its nominal/midpoint value to either extreme. (Load step = 50%.)  
4 Nominal line voltage, no load/full load condition.  
5 Please refer to the Part Number Structure for additional part numbers and options.  
PART NUMBER STRUCTURE  
U QQ - 5 / 17 - Q12 N B 9 Lx - C  
RoHS-6 hazardous substance compliant  
(please include this designator for all models)  
Output Configuration  
Quarter-Brick Package  
Nominal Output Voltage  
Maximum Rated Output  
Pin Length Option  
Blank = Std. pin length  
L1 = 0.110 (2.79mm)  
L2 = 0.145 (3.68mm)  
Alternate pin lengths  
require quantity order.  
}
Baseplate Pin 9 (special order):  
Blank = No pin 9, standard  
9 = Pin 9 installed, connects to baseplate  
Input Voltage Range  
Q12 = 9-36V  
Q48 = 18-75V  
Baseplate (optional):  
Blank = no baseplate standard  
B = baseplate installed, special order  
Remote On/Off Control Polarity:  
Add "P" for positive polarity  
Add "N" for negative polarity  
Note: Some model number combi-  
nations may not be available.  
Contact Murata Power Solutions.  
Some model options may require minimum order quantities.  
Pin 9 Baseplate Connection  
The UQQ series may include an optional installed baseplate for extended  
thermal management. This baseplate is electrically isolated from the rest of the  
converter. Various UQQ models are also available with an additional pin 9 on  
special quantity order which electrically connects to the baseplate. Pin 9 is also  
isolated from the rest of the converter. Please refer to the mechanical drawings.  
The baseplate may be ordered by adding a “B” to the model number tree  
and pin 9 will be pre-installed by adding a “9”. The two options are separate.  
Please refer to the Ordering Guide. Do not order pin 9 without the baseplate.  
Note that “pin 9” converters may be on limited forecast, requiring minimum  
order quantities and scheduled deliveries.  
Pin 9 offers a positive method of controlling the electrical potential of the base- Please see page 9 for heatsink information.  
plate, independent of the converter. If you do not include pin 9, the baseplate  
may also be grounded by the mounting bolts.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 2 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
MECHANICAL SPECIFICATIONS  
4.76  
.187  
56.4  
2.22  
4X M3X0.5  
THRU , .10" MAX  
PENETRATION  
(4 PLS)  
INPUT/OUTPUT CONNECTIONS  
47.24  
1.860  
12.7  
.50  
Pin  
Function P32  
-Input  
0.25  
.010  
MIN  
BOTTOM  
CLEARANCE  
C
L
23.6  
.93  
REF  
1
2
3
4
5
6
7
8
9
10.9  
.43  
Remote On/Off*  
+Input  
-Output  
13.08  
.515  
REF  
-Sense  
36.8  
1.45  
Output Trim  
+Sense  
26.16  
1.030  
C
L
+Output  
Baseplate (optional)  
TOP VIEW  
SIDE VIEW  
END VIEW  
WITH  
BASEPLATE  
OPTIONAL  
END VIEW  
WITHOUT  
BASEPLATE  
* The Remote On/Off can be provided with  
either positive ("P" suffix) or negative  
("N" suffix) polarity.  
BASEPLATE  
'B' OPTION  
Important! Always connect the sense pins;  
see Application Notes.  
50.80  
2.000  
1.57 0.05  
2X .062 .002  
AT PINS 4 & 8  
1.02 0.05  
.040 .002  
AT PINS 1-3, 5-7, (9)  
C
L
.071 .002 ꢀ1.80ꢁ  
VENTED SHOULDER  
25.4  
1.00  
REF  
Dimensions are in inches (mm shown for ref. only).  
ON EACH  
.040 PIN  
3.81  
.150  
Third Angle Projection  
7.62  
.300  
3.81  
.150  
8
7
6
5
4
3
2
9
1
C
L
C
L
18.42  
.725  
REF  
Tolerances (unless otherwise specified):  
.XX 0.02 (0.5)  
.XXX 0.010 (0.25)  
Angles 2ꢀ  
7.62  
.300  
BOTTOM VIEW  
Optional pin #9  
Connects to baseplate  
And is electrically  
Components are shown for reference only.  
isolated from converter  
Soldering Guidelines  
Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceeding these specifica-  
tions may cause damage to the product. Be cautious when there is high atmospheric humidity. We strongly recommend a mild pre-bake (100° C. for 30 minutes). Your production  
environment may differ; therefore please thoroughly review these guidelines with your process engineers.  
Wave Solder Operations for through-hole mounted products (THMT)  
For Sn/Ag/Cu based solders:  
For Sn/Pb based solders:  
Maximum Preheat Temperature 115° C.  
Maximum Preheat Temperature 105° C.  
Maximum Pot Temperature  
Maximum Solder Dwell Time  
270° C.  
Maximum Pot Temperature  
250° C.  
7 seconds Maximum Solder Dwell Time  
6 seconds  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 3 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
Performance and Functional Specifications  
UQQ-3.3/25-Q12  
UQQ-3.3/25-Q48  
UQQ-5/17-Q12  
UQQ-5/20-Q48  
UQQ-12/8-Q12  
INPUT  
Input Voltage Range  
Start-up Threshold  
Undervoltage Shutdown  
Overvoltage Shutdown  
Reflected (back) ripple current (2)  
Input Current  
See ordering guide  
9.0 Volts  
9.0 Volts  
8.0 Volts  
37.5 Volts  
25mAp-p  
17.50 Volts  
16.75 Volts  
None  
17.5 Volts  
9.0 Volts  
8.0 Volts  
15.75 Volts (IOUT = ØA)  
None  
8.0 Volts  
37.5 Volts  
75mAp-p  
37.5 Volts  
15mAp-p  
75mAp-p  
80mAp-p  
Full load conditions  
Inrush transient  
See ordering guide  
0.1A2sec  
Output short circuit  
No load  
250mA  
100mA  
100mA  
50mA  
250mA  
150mA  
80mA  
150mA  
65mA  
180mA  
Low line (VIN = min.)  
10.4 Amps  
5.18 Amps  
10.44 Amps  
6.24 Amps  
12.12 Amps  
Standby mode  
(Off, UV, OT shutdown)  
8mA  
2mA  
8mA  
5mA  
5mA  
Internal Input Filter Type  
LC  
Pi-type  
NA  
L-C  
L-C  
L-C  
Reverse Polarity Protection  
Yes (15)  
Yes (15)  
Yes (15)  
Yes (15)  
Remote On/Off Control (5)  
Positive logic (“P” suffix)  
OFF = Ground pin to +0.8V max. ON = open or +3.5-15V max.  
OFF = open or +5 to +VIN max. ON = Ground pin to +0.8V max. (16)  
Negative logic (“N” suffix)  
On/Off Current  
1 mA  
1 mA  
1 mA  
1mA  
1 mA  
OUTPUT  
Voltage Output Range  
See ordering guide  
1% of VNOM  
Voltage Output Accuracy  
(50% load)  
Adjustment Range  
10% of VNOM  
10% of VNOM  
–20 to +10% of VNOM  
–20 to +10% of VNOM  
–20 to +10% of VNOM  
0.02% of  
VOUT range/°C  
Temperature Coefficient  
Minimum Loading  
No minimum load  
+10%  
Remote Sense Compensation  
Ripple/noise (20MHz bandwidth)  
Line/Load Regulation  
Efficiency  
See ordering guide  
10,000μF  
Maximum Capacitive Loading  
10,000μF  
4700μF  
10,000μF  
4700μF  
Low ESR <0.02Ω max., resistive load  
Isolation Voltage  
Input to Output  
2000 VDC min.  
1500 VDC min.  
1500 VDC min.  
100MΩ  
2250 VDC min.  
1500 VDC min.  
500 VDC min.  
100MΩ  
2000 VDC min.  
1500 VDC min.  
750 VDC min.  
100MΩ  
2250 VDC min.  
1500 VDC min.  
1500 VDC min.  
100MΩ  
2250 VDC min.  
1500 VDC min.  
750 VDC min.  
100MΩ  
Input fo baseplate  
Baseplate to output  
Isolation resistance  
Isolation capacitance  
Isolation safety rating  
1500 pF  
1000 pF  
1000 pF  
1500pF  
1000 pF  
Basic insulation  
20.5 Amps  
Current limit inception  
30 Amps  
29 Amps  
27 Amps  
9.5 Amps  
(98% of VOUT, after warmup)  
Short Circuit Protection Method  
Short Circuit Current  
Current limiting, hiccup autorestart. Remove overload for recovery.  
5 Amps 3 Amps 0.5 Amps  
Continuous, output shorted to ground (no damage)  
3.96 Volts max. 6 Volts 6 Volts  
5 Amps  
4 Volts  
0.5 Amps  
14.4 Volts  
Short Circuit Duration  
Overvoltage Protection  
via magnetic feedback  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 4 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
Performance and Functional Specifications (continued)  
UQQ-12/8-Q48  
UQQ-15/7-Q12  
UQQ-24/4-Q12  
INPUT  
Input Voltage Range  
See ordering guide  
9.0 Volts  
Start-up Threshold  
Undervoltage Shutdown  
Overvoltage Shutdown  
Reflected (back) ripple current (2)  
Input Current  
17.5 Volts  
16.0 Volts  
None  
9.0 Volts  
8.0 Volts  
8.0 Volts  
None  
38.5 Volts  
15mAp-p  
50mAp-p  
50mAp-p  
Full load conditions  
Inrush transient  
See ordering guide  
0.1A2sec  
Output short circuit  
No load  
100mA  
70mA  
5.93A  
250mA  
250mA  
250mA  
120mA  
Low line (VIN = min.)  
12.9 Amps  
10.73 Amps  
Standby mode  
(Off, UV, OT shutdown)  
2mA  
5mA  
5mA  
Internal Input Filter Type  
PI-type  
NA  
L-C  
L-C  
Reverse Polarity Protection  
Yes (15)  
Yes (15)  
Remote On/Off Control (5)  
Positive logic (“P” suffix)  
OFF = Ground pin to +0.8V max. ON = open or +3.5-15V max.  
OFF = open or +5 to +VIN max. ON = Ground pin to +0.8V max. (16)  
1 mA  
Negative logic (“N” suffix)  
On/Off Current  
OUTPUT  
Voltage Output Range  
See ordering guide  
Voltage Output Accuracy  
(50% load)  
1.25% of VNOM  
1% of VNOM  
1% of VNOM  
Adjustment Range  
–20 to +10% of VNOM  
–20 to +10% of VNOM  
10% of VNOM  
Temperature Coefficient  
0.02% of  
VOUT range/°C  
Minimum Loading  
No minimum loading  
+10%  
Remote Sense Compensation  
Ripple/noise (20MHz bandwidth)  
Line/Load Regulation  
Efficiency  
+10%  
+10%  
See ordering guide  
4700μF  
Maximum Capacitive Loading  
2200ꢁF  
1500μF max  
Low ESR <0.02Ω max., resistive load  
Isolation Voltage  
Input to Output  
2250 VDC min.  
1500 VDC min.  
500 VDC min.  
100MΩ  
2000 VDC min.  
1500 VDC min.  
1500 VDC min.  
100MΩ  
2000 VDC min.  
1500 VDC min.  
1500 VDC min.  
100MΩ  
Input fo baseplate  
Baseplate to Output  
Isolation resistance  
Isolation capacitance  
Isolation safety rating  
1000 pF  
1000 pF  
1000 pF  
Basic insulation  
9.5 Amps  
Current limit inception  
12 Amps  
5.75 Amps  
(98% of VOUT, after warmup)  
Short Circuit Protection Method  
Short Circuit Current  
Current limiting, hiccup autorestart. Remove overload for recovery  
0.1 Amps  
0.5 Amps  
0.5 Amps  
Short Circuit Duration  
Continuous, output shorted to ground (no damage)  
Overvoltage Protection  
15 Volts  
18 Volts  
29 Volts  
via magnetic feedback  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 5 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
UQQ-3.3/25-Q12 UQQ-3.3/25-Q48 UQQ-5/17-Q12 UQQ-5/20-Q48 UQQ-12/8-Q12 UQQ-12/8-Q48 UQQ-15/7-Q12 UQQ-24/4-Q12  
DYNAMIC CHARACTERISTICS  
Dynamic Load Response  
(50-75-50% load step)  
50μsec to 1% 100μsec to 1%  
50μsec to 1%  
of final value  
95μsec to 1% 50μsec to 1% 50μsec to 2%  
of final value of final value of final value  
of final value  
of final value  
Start-up Time  
VIN to VOUT regulated  
10msec  
5msec  
10msec max  
5msec max  
10msec  
25msec  
10msec  
20msec  
5msec  
10msec  
10msec  
Remote On/Off  
to VOUT regulated  
Switching frequency  
ENVIRONMENTAL  
255 25kHz  
255 25kHz  
260 25kHz  
225-265kHz  
260 25kHz  
245 20kHz  
260 25kHz  
260 25kHz  
Calculated MTBF (4)  
TBC  
Operating Temperature Range  
See Derating curves  
–40 to +85ºC  
with Derating  
Operating Temperature Range –40 to +105ºC  
with baseplate  
–40 to +100ºC  
–40 to +105°C –40 to +105ºC  
–40 to +105°C –40 to +100°C –40 to +105°C –40 to +105°C  
(no Derating required) (3)(14)  
Storage Temperature Range  
Thermal Protection/Shutdown  
Relative humidity  
PHYSICAL  
–55 to +125ºC  
+120ºC, measured at thermistor T1  
To +85°C/85% non-condensing  
Outline dimensions  
Baseplate material  
Pin material  
See mechanical specifications  
Aluminum  
Copper alloy  
Pin diameter  
0.04/0.062 inches, 1.016/1.524 mm  
1 ounce (28 grams)  
Weight  
Electromagnetic interference  
(conducted, external filter  
required)  
Designed to meet FCC part 15, class B, EN55022  
Safety  
Designed to meet UL/cUL 60950-1, CSA-C22.2 No.60950-1, IEC/EN 60950-1  
UL 94V-0  
Flammability  
Specification Notes:  
(8) Output noise may be further reduced by adding an external filter. See I/O Filtering and Noise  
Reduction.  
(1) All models are tested and specified with 300 lfm airflow, external 1 and 10ꢁF paralleled ceramic/  
tantalum output capacitors and a 100ꢁF external input capacitor. All capacitors are low ESR  
types. These capacitors are necessary to accommodate our test equipment and may not be  
required in your applications. All models are stable and regulate within spec under no-load  
conditions.  
(9) All models are fully operational and meet published specifications, including “cold start” at –40°C.  
On-board component package temperatures must not exceed +128°C.  
(10) Regulation specifications describe the deviation as the line input voltage or output load current is  
varied from a nominal midpoint value to either extreme.  
General conditions for Specifications are +25°C, VIN = nominal, VOUT = nominal, full load unless  
noted.  
(11) Alternate pin length and/or other output voltages are available under special quantity order.  
(12) Overvoltage shutdown on 48V input models can be eliminated under special quantity order. OV  
shutdown can be deleted in order to comply with certain telecom reliability requirements. These  
requirements attempt continued operation despite significant input overvoltage.  
(2) Input Ripple Current is tested and specified over a 5Hz to 20MHz bandwidth. Input filtering is  
CIN = 33ꢁF tantalum, CBUS = 220ꢁF electrolytic, LBUS = 12ꢁH.  
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage.  
At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current  
outputs if the total RMS current over time does not exceed the Derating curve. All Derating  
curves are presented at sea level altitude. Be aware of reduced power dissipation with increas-  
ing altitude.  
(13) Do not exceed maximum power specifications when adjusting the output trim.  
(14) Note that the converter may operate up to +105°C with the baseplate installed (+100°C for the  
UQQ-3.3/25-Q48). However, thermal self-protection occurs near +120°C Therefore, +105°C is  
recommended to avoid thermal shutdown.  
(15) If reverse polarity is accidentally applied to the input, to ensure reverse input protection, always  
connect an external input fuse in series with the +VIN input. Use approximately twice the full  
input current rating with nominal input voltage.  
(4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3,  
ground fixed conditions, TPCBOARD = +25°C, full output load, natural air convection.  
(5) The On/Off Control may be driven with external logic or by applying appropriate external voltages  
which are referenced to Input Common. The On/Off Control Input should use either an open  
collector/open drain transistor or logic gate.  
(16) For On/Off Control on negative-polarity UQQ-3.3/25-Q48N models, the maximum OFF mode  
control voltage is +13.5 Volts. For the ON mode, the range is pin grounded to +1 Volt max.  
(17) Always connect the sense pins. If they are not connected to a remote load, connect each sense  
(6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the  
selected setting.  
pin to its respective output at the converter pins.  
(7) The outputs are not intended to sink appreciable reverse current.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 6 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
They should be selected for bulk capacitance (at appropriate frequencies),  
low ESR, and high rms-ripple-current ratings. The switching nature of  
DC/DC converters requires that dc voltage sources have low ac impedance as  
highly inductive source impedance can affect system stability. In Figure 2,  
CBUS and LBUS simulate a typical dc voltage bus. Your specific system con-  
figuration may necessitate additional considerations.  
Absolute Maximum Ratings  
Input Voltage  
Continuous  
Transient (100msec)  
12V models  
0 to +36V  
+50V  
48V models  
0 to +75V  
+100V  
On/Off Control  
0V min to +13.5V max.  
See Fuse section  
Input Reverse Polarity Protection  
Output Overvoltage  
Output Current (7)  
In critical applications, output ripple/noise (also referred to as periodic  
and random deviations or PARD) can be reduced below specified limits  
using filtering techniques, the simplest of which is the installation of  
additional external output capacitors. Output capacitors function as true  
filter elements and should be selected for bulk capacitance, low ESR, and  
appropriate frequency response. In Figure 3, the two copper strips simulate  
real-world pcb impedances between the power supply and its load. Scope  
measurements should be made using BNC connectors or the probe ground  
should be less than ½ inch and soldered directly to the fixture.  
VOUT +20% max.  
Current-limited. Devices can  
withstand sustained short circuit  
without damage.  
–55 to +125°C  
Storage Temperature  
Lead Temperature  
See soldering guidelines  
Absolute maximums are stress ratings. Exposure of devices to greater than any of  
these conditions may adversely affect long-term reliability. Proper operation under  
conditions other than those listed in the Performance/Functional Specifications  
Table is not implied nor recommended.  
All external capacitors should have appropriate voltage ratings and be  
located as close to the converter as possible. Temperature variations for all  
relevant parameters should be taken into consideration. OS-CONTM organic  
semiconductor capacitors (www.sanyo.com) can be especially effective for  
further reduction of ripple/noise. The most effective combination of external  
I/O capacitors will be a function of line voltage and source impedance, as  
well as particular load and layout conditions.  
Technical Notes  
Removal of Soldered UQQ’s from Printed Circuit Boards  
Should removal of the UQQ from its soldered connection be needed, thor-  
oughly de-solder the pins using solder wicks or de-soldering tools. At no time  
should any prying or leverage be used to remove boards that have not been  
properly de-soldered first.  
7
COPPER STRIP  
+SENSE  
Input Source Impedance  
8
+OUTPUT  
UQQ converters must be driven from a low ac-impedance input source. The  
DC/DC’s performance and stability can be compromised by the use of highly  
inductive source impedances. The input circuit shown in Figure 2 is a practical  
solution that can be used to minimize the effects of inductance in the input  
traces. For optimum performance, components should be mounted close to the  
DC/DC converter.  
R
LOAD  
SCOPE  
C1  
C2  
4
5
–OUTPUT  
–SENSE  
COPPER STRIP  
C1 = 1μF CERAMIC  
I/O Filtering, Input Ripple Current, and Output Noise  
C2 = 10μF TANTALUM  
All models in the UQQ Series are tested/specified for input ripple current (also  
called input reflected ripple current) and output noise using the circuits and  
layout shown in Figures 2 and 3. External input capacitors (CIN in Figure 2)  
serve primarily as energy-storage elements.  
LOAD 2-3 INCHES (51-76mm) FROM MODULE  
Figure 3. Measuring Output Ripple/Noise (PARD)  
TO  
CURRENT  
PROBE  
OSCILLOSCOPE  
3
1
+INPUT  
–INPUT  
L
BUS  
+
V
IN  
C
BUS  
CIN  
C
C
IN = 33μF, ESR < 700m7 @ 100kHz  
BUS = 220μF, ESR < 100m7 @ 100kHz  
LBUS = 12μH  
Figure 2. Measuring Input Ripple Current  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 7 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
Start-Up Threshold and Undervoltage Shutdown  
should not be allowed to exceed 0.5V. Consider using heavier wire if this  
drop is excessive.  
Under normal start-up conditions, the UQQ Series will not begin to regulate  
properly until the ramping input voltage exceeds the Start-Up Threshold.  
Once operating, devices will turn off when the applied voltage drops below  
the Undervoltage Shutdown point. Devices will remain off as long as the  
undervoltage condition continues. Units will automatically re-start when  
the applied voltage is brought back above the Start-Up Threshold. The  
hysteresis built into this function avoids an indeterminate on/off condition  
at a single input voltage. See Performance/Functional Specifications table for  
actual limits.  
Sense is connected at the load and corrects for resistive errors only. Be  
careful where it is connected. Any long, distributed wiring and/or significant  
inductance introduced into the Sense control loop can adversely affect  
overall system stability. If in doubt, test the application, and observe the  
DC/DC’s output transient response during step loads. There should be no  
appreciable ringing or oscillation. You may also adjust the output trim slightly  
to compensate for voltage loss in any external filter elements. Do not exceed  
maximum power ratings.  
Start-Up Time  
Current Limiting  
The VIN to VOUT Start-Up Time is the interval between the point at which  
a ramping input voltage crosses the Start-Up Threshold voltage and the  
point at which the fully loaded output voltage enters and remains within its  
specified accuracy band. Actual measured times will vary with input source  
impedance, external input capacitance, and the slew rate and final value of  
the input voltage as it appears to the converter. The On/Off to VOUT start-up  
time assumes that the converter is turned off via the Remote On/Off Control  
with the nominal input voltage already applied.  
When power demands from the output falls within the current limit incep-  
tion range for the rated output current, the DC/DC converter will go into  
a current limiting mode. In this condition the output voltage will decrease  
proportionately with increases in output current, thereby maintaining a  
somewhat constant power dissipation. This is commonly referred to as  
power limiting. Current limit inception is defined as the point where the full-  
power output voltage falls below the specified tolerance. If the load current  
being drawn from the converter is significant enough, the unit will go into a  
short circuit condition. See “Short Circuit Condition.”  
On/Off Control  
Short Circuit Condition  
The primary-side, Remote On/Off Control function (pin 2) can be specified  
to operate with either positive or negative polarity. Positive-polarity devices  
("P" suffix) are enabled when pin 2 is left open or is pulled high. Positive-  
polarity devices are disabled when pin 2 is pulled low (with respect to  
–Input). Negative-polarity devices are off when pin 2 is high and on when  
pin 2 is pulled low. See Figure 4  
When a converter is in current limit mode the output voltages will drop as  
the output current demand increases. If the output voltage drops too low,  
the magnetically coupled voltage used to develop primary side voltages will  
also drop, thereby shutting down the PWM controller. Following a time-out  
period of about 50 milliseconds, the PWM will restart, causing the output volt-  
ages to begin ramping to their appropriate values. If the short-circuit condi-  
tion persists, another shutdown cycle will be initiated. This on/off cycling  
is referred to as “hiccup” mode. The hiccup cycling reduces the average  
output current, thereby preventing internal temperatures from rising to  
excessive levels. The UQQ is capable of enduring an indefinite short circuit  
output condition.  
Dynamic control of the remote on/off function is best accomplished with  
a mechanical relay or an open-collector/open-drain drive circuit (optically  
isolated if appropriate). The drive circuit should be able to sink appropriate  
current (see Performance Specifications) when activated and withstand  
appropriate voltage when deactivated.  
Thermal Shutdown  
%15)6!,%.4 #)2#5)4 &/2  
0/3)4)6% !.$ .%'!4)6%  
,/')# -/$%,3  
ꢃꢇ6  
ꢃ).054  
UQQ converters are equipped with thermal-shutdown circuitry. If the inter-  
nal temperature of the DC/DC converter rises above the designed operating  
temperature (See Performance Specifications), a precision temperature  
sensor will power down the unit. When the internal temperature decreases  
below the threshold of the temperature sensor, the unit will self start.  
/.ꢁ/&&  
#/.42/,  
#/.42/,  
2%&  
Output Overvoltage Protection  
n).054  
#/--/.  
The output voltage is monitored for an overvoltage condition via magnetic  
coupling to the primary side. If the output voltage rises to a fault condition,  
which could be damaging to the load circuitry (see Performance Specifica-  
tions), the sensing circuitry will power down the PWM controller causing  
the output voltage to decrease. Following a time-out period the PWM will  
restart, causing the output voltage to ramp to its appropriate value. If the  
fault condition persists, and the output voltages again climb to excessive  
levels, the overvoltage circuitry will initiate another shutdown cycle. This  
on/off cycling is referred to as “hiccup” mode.  
Figure 4. Driving the Remote On/Off Control Pin  
Sense Input  
Note: The sense and VOUT lines are internally connected through low-value  
resistors. Nevertheless, if sense is not used for remote regulation, the user  
must connect + sense to + VOUT and -sense to -VOUT at the converter pins.  
Sense is intended to correct small output accuracy errors caused by the  
resistive ohmic drop in output wiring as output current increases. This output  
drop (the difference between Sense and VOUT when measured at the converter)  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 8 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
Input Reverse-Polarity Protection  
8
1
2
+OUTPUT  
–INPUT  
If the input-voltage polarity is accidentally reversed, an internal diode will  
become forward biased and likely draw excessive current from the power  
source. If the source is not current limited or the circuit appropriately fused, it  
could cause permanent damage to the converter.  
7
+SENSE  
6
5
4
ON/OFF  
CONTROL  
TRIM  
–SENSE  
LOAD  
RTRIM UP  
Input Fusing  
Certain applications and/or safety agencies may require the installation of  
fuses at the inputs of power conversion components. Fuses should also be  
used if the possibility of a sustained, non-current-limited, input-voltage polarity  
reversal exists. For MPS UQQ Series DC/DC Converters, slow-blow fuses are  
recommended with values no greater than twice the maximum input current.  
3
+INPUT  
–OUTPUT  
Figure 5. Trim Connections To Increase Output Voltages Using Fixed Resistors  
Trimming Output Voltage  
8
1
+OUTPUT  
–INPUT  
UQQ converters have a trim capability (pin 6) that enables users to adjust the  
output voltage from +10% to –20% (refer to the trim equations). Adjustments  
to the output voltage can be accomplished with a single fixed resistor as shown  
in Figures 5 and 6. A single fixed resistor can increase or decrease the output  
voltage depending on its connection. Resistors should be located close to  
the converter and have TCR’s less than 100ppm/°C to minimize sensitivity to  
changes in temperature. If the trim function is not used, leave the trim pin open.  
7
+SENSE  
2
3
6
5
4
ON/OFF  
CONTROL  
TRIM  
–SENSE  
LOAD  
RTRIM DOWN  
+INPUT  
Standard UQQ’s have a "positive trim" where a single resistor connected from  
the Trim pin (pin 6) to the +Sense (pin 7) will increase the output voltage. A  
resistor connected from the Trim Pin (pin 6) to the –Sense (pin 5) will decrease  
the output voltage.  
–OUTPUT  
Figure 6. Trim Connections To Decrease Output Voltages Using Fixed Resistors  
Trim adjustments greater than the specified +10%/–20% can have an adverse  
affect on the converter’s performance and are not recommended. Excessive  
voltage differences between VOUT and Sense, in conjunction with trim adjust-  
ment of the output voltage, can cause the overvoltage protection circuitry to  
activate (see Performance Specifications for overvoltage limits).  
Trim Up  
Trim Down  
UQQ-3.3/25-Q12, UQQ-3.3/25-Q48  
13.3(VO 1.226)  
16.31  
10.2  
10.2  
10.2  
10.2  
RTUP (k7) =  
RTDOWN (k7) =  
VO 3.3  
3.3 VO  
Temperature/power derating is based on maximum output current and voltage  
at the converter’s output pins. Use of the trim and sense functions can cause  
output voltages to increase, thereby increasing output power beyond the UQQ’s  
specified rating, or cause output voltages to climb into the output overvoltage  
region. Therefore:  
UQQ-5/17-Q12, UQQ-5/20-Q48  
25.01  
20.4(VO 1.226)  
10.2  
RTDOWN (k7) =  
RTUP (k7) =  
RTUP (k7) =  
5 VO  
VO 5  
(VOUT at pins) x (IOUT) rated output power  
UQQ-12/8-Q12, UQQ-12/8-Q48  
The Trim pin (pin 6) is a relatively high impedance node that can be susceptible  
to noise pickup when connected to long conductors in noisy environments. In  
such cases, a 0.22ꢁF capacitor to –Output can be added to reduce this long  
lead effect.  
49.6(VO 1.226)  
60.45  
10.2  
RTDOWN (k7) =  
VO 12  
12 VO  
UQQ-15/7-Q12  
76.56  
62.9(VO 1.226)  
VO 15  
10.2  
10.2  
10.2  
RTDOWN (k7) =  
RTUP (k7) =  
RTUP (k7) =  
15 VO  
UQQ-24/4-Q12  
124.2  
101 × (VO 1.226)  
VO 24  
10.2  
RTDOWN (k7) =  
24 VO  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 9 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
UQQ Series Aluminum Heatsink  
Thermal Performance  
Please note – The UQQ series shares the same heatsink kits as the UVQ  
series. Therefore, when ordering these heat sinks, use the model numbers  
below which end with the ‘UVQ’ suffix. The UQQ series converter baseplate  
can be attached either to an enclosure wall or a heatsink to remove heat from  
internal power dissipation. The discussion below concerns only the heatsink  
alternative. The UQQ’s are available with a low-profile extruded aluminum  
heatsink kit, models HS-QB25-UVQ, HS-QB50-UVQ, and HS-QB100-UVQ.  
This kit includes the heatsink, thermal mounting pad, screws and mounting  
hardware. See the assembly diagram below. Do not overtighten the screws in  
the tapped holes in the converter. This kit adds excellent thermal performance  
without sacrificing too much component height. See the Mechanical Outline  
Drawings for assembled dimensions. If the thermal pad is firmly attached, no  
thermal compound (“thermal grease”) is required.  
The HS-QB25-UVQ heatsink has a thermal resistance of 12 degrees Celsius  
per Watt of internal heat dissipation with “natural convection” airflow (no  
fans or other mechanical airflow) at sea level altitude. This thermal resistance  
assumes that the heatsink is firmly attached using the supplied thermal pad  
and that there is no nearby wall or enclosure surface to inhibit the airflow. The  
thermal pad adds a negligible series resistance of approximately 0.5°C/Watt so  
that the total assembled resistance is 12.5°C/Watt.  
Be aware that we need to handle only the internal heat dissipation, not the full  
power output of the converter. This internal heat dissipation is related to the  
efficiency as follows:  
Power Dissipation [Pd] = Power In – Power Out [1]  
Power Out / Power In = Efficiency [in %] / 100 [2]  
When assembling these kits onto the converter, include ALL kit hardware to  
assure adequate mechanical capture and proper clearances. Thread relief is  
0.090" (2.3mm).  
Power Dissipation [Pd] = Power In x (1 –Efficiency%/100) [3]  
Power Dissipation [Pd] = Power Out x (1 / (Efficiency%/100) - 1) [4]  
Efficiency of course varies with input voltage and the total output power. Please  
refer to the Performance Curves.  
0!. (%!$ 3#2%7  
-ꢆ 8 ꢈ--  
ꢉ 0,#3  
Since many applications do include fans, here is an approximate equation to  
calculate the net thermal resistance:  
RΘ [at airflow] = RΘ [natural convection] / (1 + (Airflow in LFM) x  
[Airflow Constant]) [5]  
,/#+ 7!3(%2  
-ꢆ  
ꢉ 0,#3  
Where,  
RΘ [at airflow] is the net thermal resistance (in °C/W) with the amount of  
airflow available and,  
RΘ [natural convection] is the still air total path thermal resistance or in this  
&,!4 7!3(%2  
./ꢊ ꢉ  
ꢉ 0,#3  
case 12.5°C/Watt and,  
“Airflow in LFM” is the net air movement flow rate immediately at the converter.  
This equation simplifies an otherwise complex aerodynamic model but is a  
useful starting point. The “Airflow Constant” is dependent on the fan and enclo-  
sure geometry. For example, if 200 LFM of airflow reduces the effective natural  
convection thermal resistance by one half, the airflow constant would be  
0.005. There is no practical way to publish a “one size fits all” airflow constant  
because of variations in airflow direction, heatsink orientation, adjacent walls,  
enclosure geometry, etc. Each application must be determined empirically and  
the equation is primarily a way to help understand the cooling arithmetic.  
(%!43).+  
(%!4 42!.3&%2 0!$  
ꢋ0EEL OFF WHITE PLASTIC  
BACKING MATERIAL BEFORE  
ATTACHING TO HEATSINKꢌ  
This equation basically says that small amounts of forced airflow are quite  
effective removing the heat. But very high airflows give diminishing returns.  
Conversely, no forced airflow causes considerable heat buildup. At zero airflow,  
cooling occurs only because of natural convection over the heatsink. Natural  
convection is often well below 50 LFM, not much of a breeze.  
While these equations are useful as a conceptual aid, most users find it very  
difficult to measure actual airflow rates at the converter. Even if you know  
the velocity specifications of the fan, this does not usually relate directly to  
the enclosure geometry. Be sure to use a considerable safety margin doing  
thermal analysis. If in doubt, measure the actual heat sink temperature with  
a calibrated thermocouple, RTD or thermistor. Safe operation should keep the  
heat sink below 100°C.  
Figure 7. Model UQQ Heatsink Assembly Diagram  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 10 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
Calculating Maximum Power Dissipation  
Heat Sink Example  
To determine the maximum amount of internal power dissipation, find the  
ambient temperature inside the enclosure and the airflow (in Linear Feet per  
Minute – LFM) at the converter. Determine the expected heat dissipation using  
the Efficiency curves and the converter Input Voltage. You should also compen-  
sate for lower atmospheric pressure if your application altitude is considerably  
above sea level.  
Assume an efficiency of 92% and power output of 100 Watts. Using equation  
[4], Pd is about 8.7 Watts at an input voltage of 48 Volts. Using +30°C ambient  
temperature inside the enclosure, we wish to limit the heat sink temperature to  
+90°C maximum baseplate temperature to stay well away from thermal shut-  
down. The +90°C. figure also allows some margin in case the ambient climbs  
above +30°C or the input voltage varies, giving us less than 92% efficiency.  
The heat sink and airflow combination must have the following characteristics:  
The general proceedure is to compute the expected temperature rise of the  
heatsink. If the heatsink exceeds +100°C. either increase the airflow and/or  
reduce the power output. Start with this equation:  
8.7 W = (90-30) / RΘ[airflow] or,  
RΘ[airflow] = 60/8.7 = 6.9°C/W  
Internal Heat Dissipation [Pd in Watts] = (Ts – Ta)/RΘ [at airflow] [6]  
where “Ta” is the enclosure ambient air temperature and,  
where “Ts” is the heatsink temperature and,  
Since the ambient thermal resistance of the heatsink and pad is 12.5°C/W, we  
need additional forced cooling to get us down to 6.9°C/W. Using a hypothetical  
airflow constant of 0.005, we can rearrange equation [5] as follows:  
where “RΘ [at airflow]” is a specific heat transfer thermal resistance (in  
degrees Celsius per Watt) for a particular heat sink at a set airflow rate. We  
have already estimated RΘ [at airflow] in the equations above.  
(Required Airflow, LFM) x (Airflow Constant) = RΘ[Nat.Convection] /  
RΘ[at airflow] –1, or,  
(Required Airflow, LFM) x (Airflow Constant) = 12.5/6.9 –1 = 0.81  
and, rearranging again,  
Note particularly that Ta is the air temperature inside the enclosure at the  
heatsink, not the outside air temperature. Most enclosures have higher  
internal temperatures, especially if the converter is “downwind” from other  
heat-producing circuits. Note also that this “Pd” term is only the internal heat  
dissipated inside the converter and not the total power output of the converter.  
(Required Airflow, LFM) = 0.81/0.005 = 162 LFM  
162 LFM is the minumum airflow to keep the heatsink below +90°C. Increase  
the airflow to several hundred LFM to reduce the heatsink temperature further  
and improve life and reliability.  
We can rearrange this equation to give an estimated temperature rise of the  
heatsink as follows:  
Ts = (Pd x RΘ [at airflow]) + Ta [7]  
2.28  
(57.91)  
Heatsink Kit *  
Model Number  
Still Air (Natural convection)  
thermal resistance  
Heatsink height  
(see drawing)  
1.860  
(47.24)  
HS-QB25-UVQ  
HS-QB50-UVQ  
HS-QB100-UVQ  
12°C/Watt  
10.6°C/Watt  
8°C/Watt  
0.25" (6.35mm)  
0.50" (12.7mm)  
1.00" (25.4mm)  
* Kit includes heatsink, thermal pad and mounting hardware.  
1.03  
(26.16)  
1.45  
(36.83)  
These model numbers are correct for the UQQ series.  
0.140 DIA. (3.56) (4 PLACES)  
*
MATERIAL: BLACK ANODIZED ALUMINUM  
0.10  
(2.54)  
* UQQ SERIES HEATSINKS ARE AVAILABLE IN 3 HEIGHTS:  
0.25 (6.35), 0.50 (12.70) AND 1.00 (25.4)  
Dimensions in inches (mm)  
Optional Heatsink  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 11 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
Typical Performance Curves  
UQQ-3.3/25-Q12  
Efficiency vs. Line Voltage and Load Current @ 25°C  
UQQ-3.3/25-Q48P  
Efficiency vs. Line Voltage and Load Current @ 25ºC  
90  
88  
86  
84  
82  
80  
78  
76  
74  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
68  
66  
64  
V
IN = 18V  
V
V
V
V
IN = 12V  
IN = 18V  
IN = 24V  
IN = 30V  
VIN = 24V  
V
IN = 36V  
IN = 48V  
IN = 60V  
V
V
V
IN = 36V  
V
IN = 72V  
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25  
1
2
4
6
8
10  
12  
14  
16  
18  
20  
22  
24  
26  
Load Current (Amps)  
Load Current (Amps)  
UQQ-3.3/25-Q12P Maximum Current Temperature Derating  
UQQ-3.3/25-Q12PB Maximum Current Temperature Derating  
(no baseplate, VIN = 12V, air flow is transverse)  
(with baseplate, VIN = 12V, air flow is transverse)  
25  
24.5  
24  
25.0  
24.5  
24.0  
23.5  
23.0  
22.5  
22.0  
21.5  
21.0  
20.5  
20.0  
Natural Convection  
Natural Convection  
23.5  
23  
100 lfm  
22.5  
22  
100 lfm  
200 lfm  
300 lfm  
400 lfm  
21.5  
21  
200 lfm  
20.5  
20  
300 lfm  
19.5  
19  
18.5  
18  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ( C)  
Ambient Temperature ( C)  
°
°
UQQ-3.3/25-Q48 Maximum Current Temperature Derating at sea level  
(VIN = 48V, with baseplate, transverse air flow)  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
14  
13  
Natural Convection  
100 LFM  
200 LFM  
300 LFM  
400 LFM  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature ( C)  
°
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 12 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
Typical Performance Curves  
511ꢀꢁꢂꢃꢄꢀ1ꢃꢅ0  
511ꢀꢁꢂꢃꢄꢀ1ꢃꢅ0  
0OWER $ISSIPATION VSꢆ ,OAD #URRENT   ꢅꢁ—#  
%FFICIENCY VSꢆ ,INE 6OLTAGE AND ,OAD #URRENT   ꢅꢁ—#  
ꢀꢁ  
ꢀꢂ  
ꢀꢃ  
ꢄꢄ  
ꢄꢅ  
ꢄꢁ  
ꢄꢂ  
ꢄꢃ  
ꢆꢄ  
ꢆꢅ  
ꢆꢁ  
ꢇꢇ  
ꢇꢃ  
6
). ꢎ ꢆꢏ6  
). ꢎ ꢆꢐ6  
). ꢎ ꢄꢉ6  
6
6
6). ꢎ ꢅꢄ6  
6
). ꢎ ꢑ6  
). ꢎ ꢅꢄ6  
). ꢎ ꢄꢉ6  
). ꢎ ꢆꢐ6  
6). ꢎ ꢑ6  
6
6
6
6
). ꢎ ꢆꢏ6  
ꢇꢈꢆ  
ꢉꢈꢁ  
ꢊꢈꢇ  
ꢅꢈꢄ  
ꢄꢈꢊ  
ꢇꢃꢈꢂ  
ꢇꢇꢈꢀ  
ꢇꢉꢈꢅ  
ꢇꢊꢈꢉ  
ꢇꢆ  
ꢇꢈꢆ  
ꢉꢈꢁ  
ꢊꢈꢇ  
ꢅꢈꢄ  
ꢄꢈꢊ  
ꢇꢃꢈꢂ  
ꢇꢇꢈꢀ  
ꢇꢉꢈꢅ  
ꢇꢊꢈꢉ  
ꢇꢆ  
,OAD #URRENT ꢇ!MPSꢈ  
,OAD #URRENT ꢇ!MPSꢈ  
UQQ-5/17-Q12P Maximum Current Temperature Derating  
UQQ-5/17-Q12P Maximum Current Temperature Derating  
No baseplate, VIN = 12V (transverse air flow at sea level)  
With baseplate, VIN = 12V (transverse air flow at sea level)  
17  
16  
15  
14  
13  
12  
11  
17  
16  
15  
14  
13  
12  
11  
400 lfm  
300 lfm  
Natural Convection  
100 lfm  
200 lfm  
Natural Convection  
100 lfm  
300 lfm  
400 lfm  
200 lfm  
85  
25  
30  
35  
40  
45  
Ambient Temperature ( C)  
50  
55  
60  
65  
70  
75  
80  
85  
–40  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
–40  
Ambient Temperature ( C)  
°
°
UQQ-5/20-Q48P  
Efficiency vs. Line Voltage and Load Current @ 25°C  
UQQ-5/20-Q48 Maximum Current Temperature Derating at sea level  
(VIN = 48V, with baseplate, transverse airflow)  
20  
19  
18  
17  
16  
15  
14  
13  
12  
11  
90  
85  
80  
75  
70  
65  
V
IN = 75V  
IN = 60V  
V
VIN = 48V  
VIN = 36V  
VIN = 24V  
VIN = 18V  
Natural Convection  
100 lfm  
200 lfm  
300 lfm  
400 lfm  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature ( C)  
°
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20  
Load Current (Amps)  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 13 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
Typical Performance Curves  
511ꢀꢃꢅꢂꢉꢀ1ꢃꢅ0  
%FFICIENCY VSꢆ ,INE 6OLTAGE AND ,OAD #URRENT   ꢅꢁ—#  
511ꢀꢃꢅꢂꢉꢀ1ꢃꢅ  
0OWER $ISSIPATION VSꢆ ,OAD #URRENT   ꢅꢁ—#  
ꢀꢂ  
ꢀꢃ  
ꢄꢄ  
ꢄꢅ  
ꢄꢁ  
ꢄꢂ  
ꢄꢃ  
ꢆꢄ  
ꢇꢂ  
ꢇꢇ  
ꢇꢃ  
6
). ꢎ ꢆꢏ6  
). ꢎ ꢆꢐ6  
6
6
). ꢎ ꢄꢉ6  
). ꢎ ꢅꢄ6  
6
6
). ꢎ ꢑ6  
). ꢎ ꢅꢄ6  
). ꢎ ꢄꢉ6  
6). ꢎ ꢑ6  
6
6
6
). ꢎ ꢆꢐ6  
6
). ꢎ ꢆꢏ6  
,OAD #URRENT ꢇ!MPSꢈ  
,OAD #URRENT ꢇ!MPSꢈ  
UQQ-12/8-Q12P Maximum Current Temperature Derating  
UQQ-12/8-Q12P Maximum Current Temperature Derating  
(no baseplate, VIN = 12V, air flow is transverse)  
With baseplate, VIN = 12V (transverse air flow at sea level)  
8.0  
7.5  
7.0  
6.5  
6.0  
5.5  
5.0  
4.5  
4.0  
8.0  
7.5  
7.0  
6.5  
6.0  
5.5  
5.0  
4.5  
4.0  
Natural Convection  
100 lfm  
100 lfm  
200 lfm  
300 lfm  
400 lfm  
200 lfm  
Natural Convection  
300 lfm  
400 lfm  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
–40  
25  
30  
35  
40  
45  
Ambient Temperature ( C)  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ( C)  
°
°
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 14 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
Typical Performance Curves  
UQQ-12/8-Q48P  
Efficiency vs. Line Voltage and Load Current @ 25°C  
UQQ-12/8-Q48P Maximum Current Temperature Derating  
(With baseplate, VIN = 48V transverse air flow at sea level)  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
8
7.5  
7
6.5  
6
V
IN = 18V  
IN = 36V  
IN = 48V  
100 lfm  
200 lfm  
V
5.5  
5
V
300 lfm  
400 lfm  
V
IN = 75V  
4.5  
4
Natural Convection  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
1
2
3
4
5
6
7
8
Ambient Temperature ( C)  
°
Load Current (Amps)  
UQQ-12/8-Q48P Maximum Current Temperature Derating  
(With baseplate, VIN = 24V, transverse air flow at sea level)  
8
7.5  
7
6.5  
6
100 lfm  
200 lfm  
300 lfm  
400 lfm  
5.5  
5
Natural Convection  
4.5  
4
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature ( C)  
°
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 15 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
Typical Performance Curves  
511ꢀꢃꢁꢂꢄꢀ1ꢃꢅ0  
%FFICIENCY VSꢆ ,INE 6OLTAGE AND ,OAD #URRENT   ꢅꢁ—#  
511ꢀꢃꢁꢂꢄꢀ1ꢃꢅ0  
0OWER $ISSIPATION VSꢆ ,OAD #URRENT   ꢅꢁ—#  
ꢀꢂ  
ꢀꢃ  
ꢄꢄ  
ꢄꢅ  
ꢄꢁ  
ꢄꢂ  
ꢄꢃ  
ꢆꢄ  
ꢇꢂ  
ꢇꢇ  
ꢇꢃ  
6
). ꢎ ꢆꢏ6  
). ꢎ ꢆꢐ6  
). ꢎ ꢄꢉ6  
6
6
6
). ꢎ ꢅꢄ6  
6
). ꢎ ꢑ6  
). ꢎ ꢅꢄ6  
). ꢎ ꢄꢉ6  
). ꢎ ꢆꢐ6  
). ꢎ ꢆꢏ6  
6
6
6
6
6
). ꢎ ꢑ6  
,OAD #URRENT ꢇ!MPSꢈ  
,OAD #URRENT ꢇ!MPSꢈ  
UQQ-15/7-Q12P Maximum Current Temperature Derating  
With baseplate, VIN = 12V (transverse air flow at sea level)  
7
6.5  
6
400 lfm  
300 lfm  
5.5  
5
4.5  
4
Natural Convection  
100 lfm  
200 lfm  
3.5  
–40  
25  
30  
35  
40  
45  
Ambient Temperature ( C)  
50  
55  
60  
65  
70  
75  
80  
85  
°
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 16 of 17  
UQQ Series  
Wide Input Range Single Output DC/DC Converters  
Typical Performance Curves  
UQQ-24/4-Q12P  
Efficiency vs. Line Voltage and Load Current @ 25°C  
UQQ-24/4-Q12P  
Power Dissipation vs. Load Current @ 25°C  
93  
92  
91  
90  
89  
88  
87  
86  
14  
13  
12  
11  
10  
9
VIN = 36V  
VIN = 30V  
VIN = 24V  
VIN = 12V  
VIN = 10V  
V
V
IN = 10V  
IN = 12V  
8
7
V
IN = 24V  
6
5
VIN = 30V  
4
V
IN = 36V  
3
2
1
2
3
4
1
2
3
4
Load Current (Amps)  
Load Current (Amps)  
UQQ-24/4-Q12P Maximum Current Temperature Derating  
UQQ-24/4-Q12P Maximum Current Temperature Derating  
No baseplate, VIN = 12V (transverse air flow at sea level)  
With baseplate, VIN = 12V (transverse air flow at sea level)  
4
3.8  
3.6  
3.4  
3.2  
3
4
3.8  
3.6  
3.4  
3.2  
3
400 lfm  
300 lfm  
400 lfm  
300 lfm  
Natural Convection  
2.8  
2.6  
2.4  
2.2  
2
2.8  
2.6  
2.4  
2.2  
2
100 lfm  
Natural Convection  
100 lfm  
200 lfm  
200 lfm  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ( C)  
Ambient Temperature ( C)  
°
°
USA:  
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com  
Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com  
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com  
Canada:  
UK:  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356  
France:  
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com  
München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com  
Germany:  
Japan:  
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com  
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com  
www.murata-ps.com email: sales@murata-ps.com ISO 9001 and 14001 REGISTERED  
12/15/08  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
China:  
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com  
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com  
notice.  
© 2008 Murata Power Solutions, Inc.  
Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UQQ.A10 Page 17 of 17  

相关型号:

UQQ-24/4-Q12P9L1-C

DC-DC Regulated Power Supply Module, 1 Output, 96W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-9
MURATA

UQQ-24/4-Q12P9L2-C

DC-DC Regulated Power Supply Module, 1 Output, 96W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-9
MURATA

UQQ-24/4-Q12PB-C

DC-DC Regulated Power Supply Module,
MURATA

UQQ-24/4-Q12PB9L1-C

DC-DC Regulated Power Supply Module, 1 Output, 96W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-9
MURATA

UQQ-24/4-Q12PB9L2-C

DC-DC Regulated Power Supply Module, 1 Output, 96W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-9
MURATA

UQQ-244-Q12P-C

Wide Input Range Single Output DC-DC Converters
MURATA

UQQ-3.3

Wide Input Range Single Output DC-DC Converters
MURATA

UQQ-3.3/25-Q12N-C

民用设备,工业设备
MURATA

UQQ-3.3/25-Q12NB-C

民用设备,工业设备
MURATA

UQQ-3.3/25-Q12P-C

Wide Input Range Single Output DC/DC Converters
MURATA

UQQ-3.3/25-Q12P9L2-C

DC-DC Regulated Power Supply Module, 1 Output, 82.5W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-9
MURATA

UQQ-3.3/25-Q12PB-C

民用设备,工业设备
MURATA