UWE-15/5-Q48P-C [MURATA]

DC-DC Regulated Power Supply Module,;
UWE-15/5-Q48P-C
型号: UWE-15/5-Q48P-C
厂家: muRata    muRata
描述:

DC-DC Regulated Power Supply Module,

文件: 总23页 (文件大小:695K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
UWE Series  
s
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
The UWE Series "Eighth-Brick" DC-DC Converters are high-current isolated  
power modules designed for use in high-density system boards.  
Typical unit  
FEATURES  
PRODUCT OVERVIEW  
  
Industry-standard through-hole eighth-brick  
package with 0.9" x 2.3" x 0.38" outline  
dimensions  
With dimensions of only 0.9 by 2.3 by 0.38  
inches, the UWE series open frame DC-DC convert-  
ers deliver up to 75 Watts in an industry-standard  
“eighth-brick” through-hole package. This format  
can plug directly into quarter-brick pinouts. Several  
standard fixed-output voltages from 3.3 Vdc to 24  
Vdc assure compatibility in embedded equipment,  
tight line/load regulation, stable no-load operation  
and fast load step response. All units are precision  
assembled in a highly automated facility with ISO-  
traceable manufacturing quality standards.  
Isolation of 2250 Volts (Q48 models) assures  
safety and fully differential (floating) operation for  
greatest application flexibility. On-board Sense in-  
  
Choice of two wide input ranges, 9-36 Vdc or  
18-75 Vdc  
  
Fixed output from 3.3 to 24 Volts DC up to 75  
Watts  
CPU cards and instrument subsystems. The extend- puts compensate for line drop errors at high output  
  
Synchronous rectification yields very high  
efficiency and low power dissipation  
ed 4-to-1 input power range (9-36V) is ideal for  
battery-powered, telecom or portable applications.  
Very high efficiency means no fans or temperature  
deratings in many applications. An optional thermal  
mounting baseplate extends operation into most  
conceivable environments.  
currents. Outputs are trimmable within 10ꢀ of  
nominal voltage. The UWE series are functionally  
complete.  
  
Operating temperature range from -40 to  
+85˚C with derating  
A wealth of protection features prevents damage  
to both the converter and outside circuits. Inputs  
are protected from undervoltage and outputs fea-  
ture short circuit protection, overcurrent and excess  
temperature shut down. Overloads automatically  
recover using the “hiccup” technique upon fault  
removal. The UWE is certified to standard safety  
and EMI/RFI approvals. All units meet RoHS-6  
hazardous materials compliance.  
  
Up to 2250 Volt DC isolation (Q48 models)  
  
Outstanding thermal performance and derating  
The synchronous rectifier design uses the  
maximum available duty cycle for greatest ef-  
ficiency and low power dissipation with no reverse  
output conduction. Other features include low  
on-resistance FET’s, planar magnetics and heavy-  
copper PC boards. These deliver low output noise,  
  
Extensive self-protection, overtemperature  
and overload features with no output reverse  
conduction  
  
On/Off control, trim and remote sense functions  
  
Certified to UL/EN/IEC 60950-1, CAN/CSA-C22.2  
No. 60950-1, 2nd Edition, safety approvals  
and EN55022/CISPR22 standards  
  
Pre-bias operation for startup protection  
+VOUT  
+VIN  
SWITCH  
DRIVE  
VOLTAGE  
+SENSE  
−VOUT  
REGULATOR  
SS  
PWM  
–VIN  
−SENSE  
TRIM  
ON/OFF  
CONTROL  
REFERENCE  
AMPLIFIER,  
TRIM AND FEEDBACK  
ISOLATION  
UV, OT  
Typical topology is shown.  
Figure 1. Simplified Block Diagram  
For full details go to  
www.murata-ps.com/rohs  
Q48 models only  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 1 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE  
Output  
Input  
IIN, no  
Efficiency  
IIN, full  
R/N (mVp-p)  
Regulation (max.)  
VOUT  
(V)  
IOUT  
(A)  
Power  
(W)  
VIN Nom. Range  
load  
load  
(A)  
Package  
(Case, Pinout)  
Root Model  
UWE-3.3/20-Q12  
UWE-3.3/20-Q48  
UWE-5/15-Q12  
UWE-5/15-Q48  
UWE-12/6-Q12  
UWE-12/6-Q48  
UWE-15/5-Q12  
UWE-15/5-Q48  
UWE-24/3-Q12   
Typ.  
80  
Max.  
125  
225  
125  
150  
180  
150  
125  
150  
275  
Line  
Load  
(V)  
12  
48  
12  
48  
12  
48  
12  
48  
12  
(V)  
(mA)  
Min.  
87ꢀ  
Typ.  
89ꢀ  
3.3  
3.3  
20  
20  
15  
15  
6
66  
66  
75  
75  
72  
72  
75  
75  
72  
0.25ꢀ  
0.2ꢀ  
0.25ꢀ  
0.25ꢀ  
0.125ꢀ  
0.15ꢀ  
0.05ꢀ  
0.075ꢀ  
0.075ꢀ  
0.125ꢀ  
0.125ꢀ  
9-36  
160  
75  
6.18  
1.54  
6.87  
1.74  
6.56  
1.65  
6.83  
1.73  
6.70  
165  
80  
18-75  
9-36  
88ꢀ  
89.5ꢀ  
91ꢀ  
5.0  
0.25ꢀ  
0.2ꢀ  
185  
90  
89ꢀ  
5.0  
135  
120  
115  
65  
18-75  
9-36  
88.5ꢀ  
90ꢀ  
90ꢀ  
12.0  
12.0  
15.0  
15.0  
24.0  
0.125ꢀ  
0.1ꢀ  
200  
90  
91.5ꢀ  
91ꢀ  
C77, P32  
6
18-75  
9-36  
89ꢀ  
5
0.125ꢀ  
0.125ꢀ  
0.125ꢀ  
270  
90  
89.5ꢀ  
89ꢀ  
91.5ꢀ  
90.5ꢀ  
89.5ꢀ  
5
90  
18-75  
9-36  
3
190  
110  
88.3ꢀ  
Please refer to the part number structure for additonal ordering model numbers and options.  
All specifications are at nominal line voltage, nominal output voltage and full load, +25° C.  
unless otherwise noted. See detailed specifications.  
I/O caps are necessary for our test equipment and may not be needed for your application.  
Load regulation range: 0.1-3A. This is required only for our test equipment. The converter will  
operate at zero output current with degraded regulation.  
Output capacitors are 1 μF ceramic in parallel with 10 μF electrolytic. Input cap is 100 μF. All  
caps are low ESR types. Contact Murata Power Solutions for details.  
PART NUMBER STRUCTURE  
U W E - 12 / 6 - Q12 P B H LX - C  
Unipolar, Single-Output  
RoHS Hazardous Materials Compliance  
C=RoHS-6, standard (does not claim EU RoHS exemption 7b–lead in solder)  
Pin Length Option  
Wide Input Range  
Blank = Standard pin length 0.19 inches (4.8mm)  
L1 = Pin length 0.110 inches (2.79mm)*  
L2 = Pin length 0.145 inches (3.68mm)*  
Eighth-Brick Package  
Nominal Output Voltage  
Conformal Coating Option  
Blank = No coating, standard  
H = Coating added, optional*  
*Special quantity order is required;  
no sample quantities available.  
(built to order; contact Murata Power Solutions for MOQ and lead times.)  
Maximum Rated Output  
Current in Amps  
Baseplate (optional)  
Note:  
Blank = No baseplate (standard)  
B = Baseplate installed (optional special order)  
Some model number combinations  
may not be available. Please contact  
Murata Power Solutions.  
Input Voltage Range  
On/Off Control Logic  
Q12 = 9-36 Volts  
Q48 = 18-75 Volts  
P = Positive logic (standard for Q12 models, optional for Q48 models)  
N = Negative logic (standard for Q48 models, optional special order for Q12 models)  
Special Customer Configuration part numbers:  
1) UWE-12/6-Q48NB-C-CIS  
2) UWE-12/6-Q48NBL1-C-CIS  
3) UWE-15/5-Q12P-31318-C (tested to 2500Vdc isolation; all other  
standard product specifications plus conformal coating apply.)  
4) UWE-12/6-Q48NBHL1-C-CIS  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 2 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
FUNCTIONAL SPECIFICATIONS, Q12 MODELS  
18  
UWE-3.3/20-Q12  
UWE-5/15-Q12  
UWE-12/6-Q12  
UWE-15/5-Q12  
UWE-24/3-Q12  
Specs are typical unless noted.  
INPUT  
Input voltage range  
See ordering guide  
Start-up threshold, Volts  
Undervoltage shutdown, V.  
Overvoltage shutdown, V.  
Reflected (back) ripple current, mA pk-pk  
Suggested external fast blow fuse, A  
Input current  
9.5  
8.5  
9
8
8
none  
40  
8.2  
8
25  
25  
10  
20  
1
40  
20  
20  
20  
Full load conditions  
See ordering guide  
Inrush transient, A2sec  
Input current if output is in short circuit, mA  
No load, mA  
0.1 A2sec  
250  
160  
8.33  
8
200  
185  
9.42  
5
250  
250  
270  
9.36  
5
250  
110  
9.04  
5
200  
Low line (Vin=min.), Amps  
Standby mode, mA  
8.89  
5
(Off, UV, OT shutdown)  
Internal input filter type  
L-C  
Reverse polarity protection  
Remote On/Off control  
None, install external fuse  
OFF=Ground pin to +0.8V max.  
ON=open pin or +3.5 to +15V max.  
OFF=open pin or +5V to +15V max.  
ON=Ground pin or 0 to +0.8V max.  
1
Positive logic ("P" model suffix)  
Negative logic ("N" model suffix)  
Current, mA  
OUTPUT  
Voltage output range  
Voltage output accuracy  
Adjustment range  
See ordering guide  
1ꢀ of Vnom., (50ꢀ load)  
-10 to +10ꢀ of Vnom.  
0.02ꢀ of Vout range per °C  
No minimum load  
Temperature coefficient  
Minimum loading  
Remote sense compensation  
Ripple/noise (20 MHz bandwidth)  
Line/Load regulation  
Efficiency  
+10ꢀ max.  
See ordering guide  
See ordering guide  
See ordering guide  
Maximum capacitive loading, μF  
low ESR, resistive load  
10,000  
10,000  
4,700  
4700  
1500  
Isolation voltage  
Input to Output, Volts min. DC  
Input to baseplate, Volts min. DC  
Baseplate to output, Volts min. DC  
Isolation resistance, MΩ  
Isolation capacitance, pF  
Isolation safety rating  
1500  
1500  
750  
100  
1500  
27  
1000  
22.5  
1000  
1000  
7.25  
1000  
4.0  
1.0  
29  
Basic insulation  
Current limit inception (98% of  
Vout, after warmup), Amps  
8.5  
Short circuit protection method  
Short circuit current, Amps  
Short circuit duration  
Current limiting, hiccup autorestart. Remove overload for recovery.  
0.5  
1.0  
6
1.5  
1.5  
18  
Continuous, output shorted to ground. No damage.  
Overvoltage protection, Volts  
(via magnetic feedback)  
4.5  
15  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 3 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
FUNCTIONAL SPECIFICATIONS, Q12 MODELS, CONTINUED  
DYNAMIC CHARACTERISTICS  
UWE-3.3/20-Q12  
UWE-5/15-Q12  
UWE-12/6-Q12  
UWE-15/5-Q12  
UWE-24/3-Q12  
Dynamic load response, μSec  
(50-75-50% load step) to 1%  
of final value  
50  
Start-up time  
Vin to Vout regulated, mSec  
Remote On/Off to Vout regulated, mSec  
Switching frequency, KHz  
ENVIRONMENTAL  
20  
5
20  
15  
40  
30  
30  
25  
40  
30  
245 25  
215-250  
275 25  
275 25  
215 15  
Operating temperature range, no baseplate  
with derating, °C (see Derating curves)  
-40 to +85 with derating  
Storage temperature range, °C  
Maximum baseplate operating temperature, °C  
Thermal protection/shutdown, °C  
Relative humidity  
-55 to +125  
+100  
+120  
to +85°C/85ꢀ non-condensing  
PHYSICAL  
Outline dimensions  
Pin material  
See mechanical specs  
Copper alloy  
Pin Finish  
Nickel underplate with gold overplate (see mechanical specs for details)  
Pin diameter, inches  
Pin diameter, mm  
0.04/0.062  
1.016/1.575  
0.7  
Weight, ounces  
Weight, grams  
20  
Electromagnetic interference (conducted)  
Safety  
Meets EN55022 and CISPR22 class B with external filter.  
Meets UL/cUL 60950-1, CSA-C22.2 No.60950-1, IEC/EN 60950-1  
FUNCTIONAL SPECIFICATIONS, Q48 MODELS  
UWE-3.3/20-Q48  
UWE-5/15-Q48  
UWE-12/6-Q48  
UWE-15/5-Q48  
Specs are typical unless noted.  
INPUT  
Input voltage range  
See ordering guide  
none  
Start-up threshold, Volts  
Undervoltage shutdown, V. (@ ½ load)  
Overvoltage shutdown, V.  
Reflected (back) ripple current, mA pk-pk  
Suggested external fast blow fuse, A  
Input current  
17.5  
16.5  
17.5  
16.0  
17.5  
16.0  
17.5  
16.0  
30  
8
30  
10  
40  
10  
40  
20  
Full load conditions  
Inrush transient, A2sec  
0.1 A2sec  
0.1 A2sec  
0.1 A2sec  
100  
0.1 A2sec  
250  
Input current if output is in short circuit, mA  
No load, mA  
150  
75  
4.1  
4
250  
90  
4.6  
5
90  
90  
Low line (Vin=min.), Amps  
Standby mode, mA  
4.35  
4
4.71  
5
(Off, UV, OT shutdown)  
Internal input filter type  
Pi-type  
L-C  
Pi-type  
L-C  
Reverse polarity protection  
Remote On/Off control  
None, install external fuse  
OFF = Ground pin to +0.8V max.  
ON = Open pin or +3.5V to +15V max.  
OFF = Open pin or +5V to +15V max.  
ON = Ground pin to +1V max.  
1
Positive logic ("P" model suffix)  
Negative logic ("N" model suffix)  
Current, mA  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 4 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
FUNCTIONAL SPECIFICATIONS, Q48 MODELS, CONTINUED  
OUTPUT  
UWE-3.3/20-Q48  
UWE-5/15-Q48  
UWE-12/6-Q48  
UWE-15/5-Q48  
Voltage output range  
See ordering guide  
Voltage output accuracy  
Adjustment range  
1ꢀ of Vnom., (50ꢀ load)  
-10 to +10ꢀ of Vnom.  
0.02ꢀ of Vout range per °C  
No minimum load  
Temperature coefficient  
Minimum loading  
Remote sense compensation  
Ripple/noise (20 MHz bandwidth)  
Line/Load regulation  
+10ꢀ max.  
See ordering guide  
See ordering guide  
See ordering guide  
Efficiency  
Maximum capacitive loading, μF  
low ESR <0.02Ω max., resistive load  
4,700  
10,000  
4,700  
3300  
Isolation voltage  
Input to Output, Volts min. DC  
Input to baseplate, Volts min. DC  
Baseplate to output, Volts min. DC  
Isolation resistance, MΩ  
Isolation capacitance, pF  
Isolation safety rating  
2250  
1500  
750  
100  
1000  
26.5  
5.0  
1500  
21.0  
1000  
8.0  
1000  
7.05  
1.5  
Basic insulation  
Current limit inception (98% of  
Vout, after warmup), Amps  
Short circuit protection method  
Short circuit current, Amps  
Short circuit duration  
Current limiting, hiccup autorestart. Remove overload for recovery.  
1.5 1.0  
Continuous, output shorted to ground. No damage.  
Overvoltage protection, Volts  
(via magnetic feedback)  
4
6.5  
15  
18  
DYNAMIC CHARACTERISTICS  
Dynamic load response, μSec  
(50-75-50% load step) to final value  
50 (to 2ꢀ)  
50 (to 2ꢀ)  
50 (to 1ꢀ)  
50 (to 1ꢀ)  
Start-up time  
Vin to Vout regulated, mSec  
Remote On/Off to Vout regulated, mSec  
Switching frequency, KHz  
ENVIRONMENTAL  
20  
10  
20  
20  
30  
20  
30  
25  
215 20  
240 20  
220 20  
225 25  
Operating temperature range, no baseplate  
with derating, °C (see Derating curves)  
-40 to +85 with derating  
-55 to +125  
Storage temperature range, °C  
Maximum baseplate operating temperature, °C  
Thermal protection/shutdown, °C  
Relative humidity  
+100  
+120  
+105  
+120  
+100  
+120  
+105  
+120  
to +85°C/85ꢀ non-condensing  
PHYSICAL  
Outline dimensions  
Pin material  
See mechanical specs  
Copper alloy  
Pin Finish  
Nickel underplate with gold overplate (see mechanical specs for details)  
Pin diameter, inches  
Pin diameter, mm  
0.04/0.062  
1.016/1.575  
Weight, ounces  
0.7  
20  
Weight, grams  
Electromagnetic interference (conducted)  
Safety  
Meets EN55022 and CISPR22 class B with external filter.  
Certified to UL/cUL 60950-1, CSA-C22.2 No.60950-1, IEC/EN 60950-1, 2nd Edition  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 5 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
Absolute Maximum Ratings  
CALCULATED MTBF (TELCORDIA SR-332 METHOD, SEE NOTE 4A)  
Model  
Hours  
1,248,001  
1,847,009  
2,273,212  
3,755,203  
5,750,120  
2,386,165  
3,294,026  
UWE-3.3/20-Q12  
UWE-5/15-Q12  
UWE-5/15-Q48  
UWE-12/6-Q12  
UWE-12/6-Q48  
Input Voltage  
Q12 Models - Volts, max. continuous  
Volts, transient, 100 mSec  
0-36 VDC  
0-50 VDC  
Q48 Models - Volts, max. continuous  
0-75 VDC  
Volts, transient, 100 mSec  
0-100 VDC  
On/Off Control  
-0.7 V. min to +15V max.  
UWE-15/5-Q48  
UWE-24/3-Q12  
Input Reverse Polarity Protection  
Output Overvoltage  
See Fuse section.  
Vout nom. +20ꢀ max.  
CALCULATED MTBF (MIL-HDBK-217N2 METHOD, SEE NOTE 4B)  
Output Current (Note 7)  
Devices can  
Current-limited.  
UWE-3.3/20-Q12  
UWE-5/15-Q12  
UWE-5/15-Q48  
UWE-12/6-Q12  
UWE-12/6-Q48  
UWE-15/5-Q48  
UWE-24/3-Q12  
1,089,141  
1,936,627  
1,657,518  
1,239,521  
828,714  
withstand sustained short circuit  
without damage.  
Overtemperature Protection  
Device includes electronic over-  
temperature shutdown protection  
under normal operation.  
-55 to +125° C.  
Storage Temperature  
Lead Temperature  
2,112,625  
2,623,370  
See soldering specifications  
Absolute maximums are stress ratings. Exposure of devices to greater than any of these  
conditions may adversely affect long-term reliability. Proper operation under conditions  
other than those listed in the Performance/Functional Specifications Table is not implied or  
recommended.  
SPECIFICATION NOTES  
CAUTION: This product is not internally fused. To comply with safety agency cer-  
tifications and to avoid injury to personnel or equipment, the user must supply an  
external fast-blow fuse to the input terminals. See fuse information.  
All Q12 models are tested and specified with external 1μF and 10μF paralleled  
ceramic/tantalum output capacitors and a 100μF external input capacitor. Q48  
models test with a 35μF input cap. All capacitors are low ESR types. Contact Murata  
Power Solutions for details. These capacitors are necessary to accommodate our  
test equipment and may not be required to achieve specified performance in your  
applications. However, Murata Power Solutions recommends using these capacitors  
in your application. All models are stable and regulate within spec under no-load  
conditions.  
9
All models are fully operational and meet published specifications, including “cold  
start” at –40° C. At full power, the package temperature of all on-board components  
must not exceed +128° C.  
1
10 Regulation specifications describe the deviation as the line input voltage or output  
load current is varied from a nominal midpoint value to either extreme.  
11 If the user adjusts the output voltage, accuracy is dependent on user-supplied  
trim resistors. To achieve high accuracy, use 1ꢀ or better tolerance metal-film  
resistors. If no trim is installed, the converter will achieve its rated accuracy. Do not  
exceed maximum power specifications when adjusting the output trim.  
12 Output current limit and short circuit protection is non-latching. When the overcur-  
rent fault is removed, the converter will immediately recover.  
All specifications are typical unless noted. General conditions for Specifications are  
+25° C, Vin=nominal, Vout=nominal, full load. Adequate airflow must be supplied  
for extended testing under power.  
Input Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input  
filtering is Cin=33 μF, Cbus=220 μF, Lbus=12 μH.  
13 Alternate pin length and/or other output voltages may be available under special  
quantity order.  
14 At zero output current, the output may contain low frequency components which  
exceed the ripple specification. The output may be operated indefinitely with no  
load.  
2
3
Note that Maximum Power Derating curves indicate an average current at nominal  
input voltage. At higher temperatures and/or lower airflow, the DC-DC converter will  
tolerate brief full current outputs if the total RMS current over time does not exceed  
the Derating curve. All Derating curves are presented at sea level altitude. Be aware  
that power dissipation degrades as altitude increases.  
15 Input Fusing: If the input voltage is reversed, a body diode will conduct consider-  
able current. Therefore, install an external protection fuse. To ensure reverse input  
protection with full output load, always connect an external input fast-blow fuse in  
series with the +Vin input. Use approximately twice the full input current rating at  
the selected input voltage.  
4a Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method  
1, Case 3, ISSUE 2, ground fixed controlled conditions, Tambient=+25°C, full output  
load, natural air convection.  
4b Mean Time Before Failure is calculated using MIL-HDBK-217F, GB ground benign,  
Tambient=+25°C, full output load, natural air convection.  
16 “Hiccup” overcurrent operation repeatedly attempts to restart the converter with a  
brief, full-current output. If the overcurrent condition still exists, the restart current  
will be removed and then tried again. This short current pulse prevents overheating  
and damaging the converter. Once the fault is removed, the converter immediately  
recovers normal operation.  
5
The Remote On/Off Control is normally controlled by a switch or open collector or  
open drain transistor. But it may also be driven with external logic or by applying  
appropriate external voltages which are referenced to Input Common.  
Short circuit shutdown begins when the output voltage degrades approximately 2ꢀ  
from the selected setting.  
The outputs are not intended to sink appreciable reverse current.  
Output noise may be further reduced by adding an external filter. See I/O Filtering  
and Noise Reduction. Larger caps (especially low-ESR ceramic capacitors) may  
slow transient response or degrade stability. Use only as much output filtering as  
needed to achieve your noise requirements and no more. Thoroughly test your  
system under full load with all components installed.  
17 Note that the converter will operate up to the rated baseplate maximum tempera-  
ture with the baseplate installed and properly heat sunk. To avoid thermal self-  
protection shutdown, do not exceed this maximum baseplate temperature.  
18 UWE-24/3-Q12 undervoltage shutdown of 8.0V is at half load.  
19 UWE-24/3-Q12 output overvoltage protection requires 0.3A minimum load.  
20 Pre-bias operation: Startup will succeed if the output setpoint voltage is higher than  
the pre-existing external output voltage.  
6
7
8
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 6 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
PERFORMANCE DATA  
UWE-3.3/20-Q12N  
Efficiency vs. Line Voltage and Load Current @ 25°C  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
Vin = 36 V  
Vin = 30 V  
Vin = 24 V  
Vin = 12 V  
Vin = 9 V  
2
4
6
8
10  
12  
14  
16  
18  
20  
Load Current (Amps)  
UWE-3.3/20-Q12N  
Maximum Current Temperature Derating @ sea level  
(VIN = 12V, transverse airflow, no baseplate)  
Maximum Current Temperature Derating @sea level  
(VIN = 12V, transverse airflow, with baseplate)  
20  
19  
18  
17  
16  
15  
14  
13  
12  
11  
20  
19  
18  
17  
16  
15  
14  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
13  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
UWE-3.3/20-Q12N  
Maximum Current Temperature Derating @sea level  
(VIN = 24V, transverse airflow, with baseplate)  
20  
19  
18  
17  
16  
15  
14  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
13  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 7 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
PERFORMANCE DATA  
UWE-3.3/20-Q48P  
Efficiency vs. Line Voltage and Load Current @ 25°C  
94  
90  
86  
82  
78  
74  
70  
66  
62  
58  
54  
50  
Vin = 75 V  
Vin = 60 V  
Vin = 48 V  
Vin = 36 V  
Vin = 24 V  
Vin = 18 V  
2
4
6
8
10  
12  
14  
16  
18  
20  
Load Current (Amps)  
UWE-3.3/20-Q48P  
Maximum Current Temperature Derating @ sea level  
(VIN = 24V, transverse airflow, no baseplate)  
Maximum Current Temperature Derating @sea level  
(VIN = 24V, transverse airflow, with baseplate)  
20  
19  
18  
17  
16  
15  
20  
19  
18  
17  
16  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
UWE-3.3/20-Q48P  
Maximum Current Temperature Derating @ sea level  
(VIN = 48V, transverse airflow, no baseplate)  
Maximum Current Temperature Derating @sea level  
(VIN = 48V, transverse airflow, with baseplate)  
20  
19  
18  
17  
16  
15  
14  
13  
12  
20  
19  
18  
17  
16  
15  
14  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 8 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
PERFORMANCE DATA  
UWE-5/15-Q12N  
Efficiency vs. Line Voltage and Load Current @ 25°C  
94  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
68  
66  
64  
62  
60  
58  
56  
54  
52  
50  
Vin = 36 V  
Vin = 24 V  
Vin = 12 V  
Vin = 9 V  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
Load Current (Amps)  
UWE-5/15-Q12N  
Maximum Current Temperature Derating @ sea level  
(VIN = 12V, transverse airflow, no baseplate)  
Maximum Current Temperature Derating @sea level  
(VIN = 12V, transverse airflow, with baseplate)  
16  
16  
15  
14  
13  
12  
11  
15.5  
15  
14.5  
14  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
13.5  
13  
12.5  
12  
11.5  
10  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
11  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 9 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
PERFORMANCE DATA  
UWE-5/15-Q48P  
Efficiency vs. Line Voltage and Load Current @ 25°C  
90  
85  
80  
75  
70  
65  
60  
Vin = 75 V  
Vin = 60 V  
Vin = 48 V  
Vin = 36 V  
Vin = 24 V  
Vin = 18 V  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
Load Current (Amps)  
UWE-5/15-Q48N  
Maximum Current Temperature Derating @ sea level  
(VIN = 24V, transverse airflow, no baseplate)  
Maximum Current Temperature Derating @sea level  
(VIN = 24V, transverse airflow, with baseplate)  
15  
14.5  
14  
15  
14.5  
14  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
13.5  
13  
13.5  
13  
12.5  
12  
12.5  
11.5  
11  
12  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
UWE-5/15-Q48N  
Maximum Current Temperature Derating @ sea level  
(VIN = 48V, transverse airflow, no baseplate)  
Maximum Current Temperature Derating @sea level  
(VIN = 48V, transverse airflow, with baseplate)  
15  
14.5  
14  
15  
14  
13  
12  
11  
10  
9
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
13.5  
13  
12.5  
12  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 10 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
PERFORMANCE DATA  
UWE-12/6-Q12N  
Efficiency vs. Line Voltage and Load Current @ 25°C  
Power Dissipation vs. Load Current @ 25°C  
10  
9
94  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
68  
8
7
Vin = 36 V  
Vin = 30 V  
Vin = 24 V  
Vin = 12 V  
Vin = 10 V  
Vin = 9 V  
6
5
Vin = 36 V  
Vin = 30 V  
Vin = 24 V  
Vin = 12 V  
Vin = 10 V  
Vin = 9 V  
4
3
2
1
1
2
3
4
5
6
1
2
3
4
5
6
Load Current (Amps)  
Load Current (Amps)  
UWE-12/6-Q12N  
Maximum Current Temperature Derating @ sea level  
(VIN = 12V, transverse airflow, no baseplate)  
Maximum Current Temperature Derating @sea level  
(VIN = 12V, transverse airflow, with baseplate)  
6.0  
6.0  
5.5  
5.0  
4.5  
4.0  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5+ m/s (300+ LFM)  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
5.5  
5.0  
4.5  
4.0  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
UWE-12/6-Q48P  
Efficiency vs. Line Voltage and Load Current @ 25°C  
94  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
68  
66  
64  
62  
Vin = 75 V  
Vin = 60 V  
Vin = 48 V  
Vin = 36 V  
Vin = 24 V  
Vin = 18 V  
60  
1
2
3
4
5
6
Load Current (Amps)  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 11 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
PERFORMANCE DATA  
UWE-12/6-Q48P  
Maximum Current Temperature Derating @ sea level  
Maximum Current Temperature Derating @sea level  
(VIN = 24V, transverse airflow, no baseplate)  
(VIN = 24V, transverse airflow, with baseplate)  
6.5  
6.0  
5.5  
5.0  
4.5  
4.0  
6.5  
6.0  
5.5  
5.0  
4.5  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
4.0  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
UWE-12/6-Q48P  
Maximum Current Temperature Derating @ sea level  
(VIN = 48V, transverse airflow, no baseplate)  
Maximum Current Temperature Derating @sea level  
(VIN = 48V, transverse airflow, with baseplate)  
6.5  
6
6.5  
6
5.5  
5
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
5.5  
5
4.5  
4
4.5  
3.5  
3
4
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
UWE-15/5-Q12P  
Efficiency vs. Line Voltage and Load Current @ 25°C  
94  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
68  
66  
64  
62  
60  
58  
56  
54  
52  
50  
0.5  
Vin = 36 V  
Vin = 24 V  
Vin = 12 V  
Vin = 9 V  
1
1.5  
2
2.5  
3
3.5  
4
4.5  
5
Load Current (Amps)  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 12 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
PERFORMANCE DATA  
UWE-15/5-Q12N  
Maximum Current Temperature Derating @ sea level  
Maximum Current Temperature Derating @sea level  
(VIN = 12V, transverse airflow, no baseplate)  
(VIN = 12V, transverse airflow, with baseplate)  
5
5
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
4.5  
4.5  
4
4
3.5  
3.5  
3
3
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
UWE-15/5-Q12N  
Maximum Current Temperature Derating @ sea level  
(VIN = 24V, transverse airflow, no baseplate)  
Maximum Current Temperature Derating @sea level  
(VIN = 24V, transverse airflow, with baseplate)  
5
5
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
4.5  
4.5  
4
4
3.5  
3.5  
3
3
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
UWE-15/5-Q48  
Efficiency vs. Line Voltage and Load Current @ 25°C  
94  
92  
90  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
Vin = 18V  
Vin = 24V  
Vin = 36V  
Vin = 48V  
Vin = 60V  
Vin = 75V  
68  
1
2
3
4
5
Load Current (Amps)  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 13 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
PERFORMANCE DATA  
UWE-15/5-Q48  
Power Dissipation vs. Load Current @ 25°C  
Maximum Current Temperature Derating @sea level  
(Vin = 24V, air flow from Pin 1 to Pin 3 on PCB, with Baseplate)  
11  
10  
9
6
5
4
8
0.33 to 2.0 m/s (65 to 400 LFM)  
7
6
Vin = 18V  
5
Vin = 24V  
Vin = 36V  
Vin = 48V  
Vin = 60V  
Vin = 75V  
4
3
3
2
2
1
1
2
3
4
5
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Load Current (Amps)  
Ambient Temperature (°C)  
UWE-15/5-Q48  
Maximum Current Temperature Derating @ sea level  
Maximum Current Temperature Derating @sea level  
(Vin = 48V, air flow from Pin 1 to Pin 3 on PCB, with Baseplate)  
(Vin = 60V, air flow from Pin 1 to Pin 3 on PCB, with Baseplate)  
6
6
5
4
3
2
5
4
3
2
0.5 to 2.0 m/s (100 to 400 LFM)  
0.33 m/s (65 LFM)  
0.33 m/s (65 LFM)  
0.5 m/s (100 LFM)  
1.0 to 2.0 m/s (200 to 400 LFM)  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
UWE-15/5-Q48  
Maximum Current Temperature Derating @ sea level  
Maximum Current Temperature Derating @sea level  
(Vin = 48V, air flow from Pin 1 to Pin 3 on PCB, no baseplate)  
(Vin = 60V, air flow from Pin 1 to Pin 3 on PCB, no baseplate)  
6
5
4
3
2
6
5
4
3
2
0.33 m/s (65 LFM)  
0.5 m/s (100 LFM)  
0.33 m/s (65 LFM)  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.0 m/s (200 LFM)  
1.5 to 2.0 m/s (300 to 400 LFM)  
1.5 to 2.0 m/s (300 to 400 LFM)  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 14 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
PERFORMANCE DATA  
UWE-24/3-Q12P  
Efficiency vs. Line Voltage and Load Current @ 25°C  
Power Dissipation vs. Load Current @ 25°C  
95  
93  
91  
89  
87  
85  
83  
81  
79  
77  
75  
73  
71  
69  
67  
65  
12  
11  
10  
9
8
Vin = 36 V  
Vin = 30 V  
Vin = 24 V  
Vin = 12 V  
Vin = 10 V  
Vin = 9 V  
7
6
Vin = 36 V  
Vin = 30 V  
Vin = 24 V  
Vin = 12 V  
Vin = 10 V  
Vin = 9 V  
5
4
3
0 5  
1
1 5  
2
2 5  
3
2
Load Current (Amps)  
0 5  
1
1.5  
2
2.5  
3
Load Current (Amps)  
Maximum Current Temperature Derating @ sea level  
(VIN = 12V, transverse airflow, no baseplate)  
Maximum Current Temperature Derating @sea level  
(VIN = 12V, transverse airflow, with baseplate)  
UWE-24/3-Q12P  
3.20  
3.10  
3.00  
3.20  
3.00  
2.80  
2.60  
2.40  
2.90  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
2.80  
2.70  
2.60  
2.50  
2.40  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
Maximum Current Temperature Derating @ sea level  
(VIN = 24V, transverse airflow, no baseplate)  
Maximum Current Temperature Derating @sea level  
(VIN = 24V, transverse airflow, with baseplate)  
UWE-24/3-Q12N  
3.2  
3
3.2  
2.8  
2.6  
2.4  
2.2  
2.8  
2.6  
2.4  
2.2  
2
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
Natural Convection  
0.5 m/s (100 LFM)  
1.0 m/s (200 LFM)  
1.5 m/s (300 LFM)  
2.0 m/s (400 LFM)  
1.8  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 15 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
MECHANICAL SPECIFICATIONS—NO BASEPLATE  
2.30  
(58.4)  
TOP VIEW  
ISOMETRIC  
VIEW  
0.90 (22.9)  
0.126 (3.17)  
0.071 (1.8)±.002 STANDOFF  
0.010 (0.254) MIN  
(HIGHEST COMP  
TO MTG PLANE)  
AT EACH  
0.040 (1.02) PIN  
END VIEW  
SIDE VIEW  
0.39  
(9.91)  
MTG PLANE  
0.125  
(3.175)  
REF  
0.19 (4.83)  
0.040(1.02) ±.002  
AT PINS 1-3, 5-7  
DOSA-Compatible  
I/O Connections  
Function  
+Vin  
0.062 (1.57) ±.002  
AT PINS 4 & 8  
Pin  
1
2
On/Off Control*  
–Vin  
3
4
–Vout  
0.15 (3.8)  
PIN 3  
2.000  
(50.80)  
5
–Sense  
Trim  
PIN 4  
PIN 5  
6
7
+Sense  
+Vout  
BOTTOM VIEW  
8
* The Remote On/Off can be provided  
with either positive (P suffix) or nega-  
tive (N suffix) logic.  
0.300  
(7.62)  
0.45  
(11.43)  
0.600  
(15.24)  
REF  
0.150 (3.81)  
0.600  
(15.24)  
0.150 (3.81)  
Connect each sense input to its  
respective Vout if sense is not con-  
nected at a remote load.  
PIN 2  
PIN 1  
PIN 6  
PIN 7  
PIN 8  
MATERIAL:  
.040 PINS: C26000 BRASS, 3/4 HARD  
.062 PINS: C10200 COPPER ALLOY, FULL HARD  
FINISH: (ALL PINS)  
GOLD (5 MICROINCHES MIN) OVER NICKEL (50 MICROINCHES MIN)  
Dimensions are in inches (mm) shown for ref. only.  
Third Angle Projection  
Tolerances (unless otherwise specified):  
.XX 0.02 (0.5)  
.XXX 0.010 (0.25)  
Angles 2˚  
Components are shown for reference only.  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 16 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
MECHANICAL SPECIFICATIONS (continued)—BASEPLATE INSTALLED  
4X THRU  
2.30  
(58.4)  
M2X0.4 - 6H  
.10" MAX SCREW  
PENETRATION  
TOP VIEW  
ISOMETRIC  
VIEW  
0.90 (22.9)  
0.625 (15.88)  
0.40  
(10.2)  
1.500  
(38.10)  
0.14 (3.6)  
ALUMINUM  
BASEPLATE  
0.071 (1.8)±.002 STANDOFF  
AT EACH 0.040 (1.02) PIN  
0.010 (0.254) MIN  
(HIGHEST COMP  
TO MTG PLANE)  
END VIEW  
SIDE VIEW  
0.50  
(12.8)  
MAX  
MTG PLANE  
0.19 (4.83)  
0.125  
(3.175)  
REF  
0.040(1.02) ±.002  
AT PINS 1-3, 5-7  
0.062 (1.57) ±.002  
AT PINS 4 & 8  
0.15 (3.8)  
PIN 3  
2.000  
(50.80)  
PIN 4  
PIN 5  
BOTTOM VIEW  
0.300  
(7.62)  
0.45  
(11.43)  
0.600  
(15.24)  
REF  
0.150 (3.81)  
0.600  
(15.24)  
0.150 (3.81)  
PIN 2  
PIN 1  
PIN 6  
PIN 7  
PIN 8  
Dimensions are in inches (mm) shown for ref. only.  
MATERIAL:  
Third Angle Projection  
.040 PINS: C26000 BRASS, 3/4 HARD  
.062 PINS: C10200 COPPER ALLOY, FULL HARD  
FINISH: (ALL PINS)  
GOLD (5 MICROINCHES MIN) OVER NICKEL (50 MICROINCHES MIN)  
Tolerances (unless otherwise specified):  
.XX 0.02 (0.5)  
.XXX 0.010 (0.25)  
Angles 2˚  
Components are shown for reference only.  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 17 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
SHIPPING TRAYS AND BOXES  
Anti-static foam  
Label  
Label  
For 1–42 pc quantity  
For 43–84 pc quantity  
SHIPPING TRAY  
UWE modules are supplied in a 21-piece (3-by-7) shipping tray. The tray is an anti-static closed-cell polyethylene foam. Dimensions are shown below.  
9.920  
(252)  
+0.000  
-0.062  
0.910 (23.1) TYP  
0.455 (11.6) TYP  
0.735 (18.7)  
9.920  
(252)  
+0.000  
-0.062  
0.625 (15.9) TYP  
2.400 (61) TYP  
Dimensions in inches (mm)  
0.25 R TYP  
1.300 (33.0) TYP  
0.25 CHAMFER TYP (4-PL)  
7.800  
1.06  
(198.1)  
(26.9)  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 18 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
The difference in start up time from VIN to VOUT and from On/Off Control to  
VOUT is therefore insignificant.  
TECHNICAL NOTES  
Soldering Guidelines  
Input Source Impedance  
Murata Power Solutions recommends the specifications below when installing these  
converters. These specifications vary depending on the solder type. Exceeding these  
specifications may cause damage to the product. Your production environment may dif-  
UWE converters must be driven from a low ac-impedance input source.  
The DC-DC’s performance and stability can be compromised by the use of  
highly inductive source impedances. For optimum performance, compo-  
nents should be mounted close to the DC-DC converter. If the application  
has a high source impedance, low VIN models can benefit from increased  
external input capacitance.  
fer; therefore please thoroughly review these guidelines with your process engineers.  
Wave Solder Operations for through-hole mounted products (THMT)  
For Sn/Ag/Cu based solders:  
Maximum Preheat Temperature  
Maximum Pot Temperature  
Maximum Solder Dwell Time  
For Sn/Pb based solders:  
Maximum Preheat Temperature  
Maximum Pot Temperature  
Maximum Solder Dwell Time  
115° C.  
I/O Filtering, Input Ripple Current, and Output Noise  
270° C.  
7 seconds  
All models in the UWE Converters are tested/specified for input reflected ripple  
current and output noise using the specified external input/output components/  
circuits and layout as shown in the following two figures.  
105° C.  
250° C.  
External input capacitors (CIN in Figure 2) serve primarily as energy-storage  
elements, minimizing line voltage variations caused by transient IR drops in  
conductors from backplane to the DC-DC. Input caps should be selected for bulk  
capacitance (at appropriate frequencies), low ESR, and high rms-ripple-current  
ratings. The switching nature of DC-DC converters requires that dc voltage  
sources have low ac impedance as highly inductive source impedance can affect  
system stability. In Figure 2, CBUS and LBUS simulate a typical dc voltage bus. Your  
specific system configuration may necessitate additional considerations.  
6 seconds  
Input Fusing  
Certain applications and/or safety agencies may require the installation of  
fuses at the inputs of power conversion components. Fuses should also be  
used if the possibility of sustained, non-current-limited, input-voltage polarity  
reversals exist. For MPS UWE DC-DC Converters, you should use fast-blow type  
fuses, installed in the ungrounded input supply line. Refer to the specifications  
for fuse values.  
All relevant national and international safety standards and regulations must  
be observed by the installer. For system safety agency approvals, the convert-  
ers must be installed in compliance with the requirements of the end-use  
safety standard, e.g., IEC/EN/UL60950-1.  
TO  
CURRENT  
PROBE  
OSCILLOSCOPE  
+VIN  
LBUS  
+
Input Undervoltage Shutdown and Start-Up Threshold  
VIN  
CBUS  
CIN  
Under normal start-up conditions, devices will not begin to regulate until  
the ramping-up input voltage exceeds the Start-Up Threshold Voltage. Once  
operating, devices will not turn off until the input voltage drops below the  
Undervoltage Shutdown limit. Subsequent re-start will not occur until the input  
is brought back up to the Start-Up Threshold. This built in hysteresis prevents  
any unstable on/off situations from occurring at a single input voltage.  
–VIN  
CIN = 33μF, ESR < 700mΩ @ 100kHz  
CBUS = 220μF, ESR < 100mΩ @ 100kHz  
LBUS = 12μH  
Figure 2. Measuring Input Ripple Current  
Start-Up Time  
The VIN to VOUT Start-Up Time is the interval of time between the point at which  
the ramping input voltage crosses the Start-Up Threshold and the fully loaded  
output voltage enters and remains within its specified accuracy band. Actual  
measured times will vary with input source impedance, external input/output  
capacitance, and load. The UWE Series implements a soft start circuit that  
limits the duty cycle of its PWM controller at power up, thereby limiting the  
input inrush current.  
In critical applications, output ripple/noise (also referred to as periodic and  
random deviations or PARD) may be reduced below specified limits using filter-  
ing techniques, the simplest of which is the installation of additional external  
output capacitors. These output caps function as true filter elements and  
should be selected for bulk capacitance, low ESR and appropriate frequency  
response. All external capacitors should have appropriate voltage ratings and  
be located as close to the converter as possible. Temperature variations for all  
relevant parameters should also be taken carefully into consideration.  
The On/Off Control to VOUT start-up time assumes the converter has its  
nominal input voltage applied but is turned off via the On/Off Control pin. The  
specification defines the interval between the point at which the converter is  
turned on and the fully loaded output voltage enters and remains within its  
specified accuracy band. Similar to the VIN to VOUT start-up, the On/Off Control  
to VOUT start-up time is also governed by the internal soft start circuitry and  
external load capacitance.  
The most effective combination of external I/O capacitors will be a function  
of line voltage and source impedance, as well as particular load and layout  
conditions.  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 19 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
Short Circuit Condition  
When a converter is in current-limit mode, the output voltage will drop as  
the output current demand increases. If the output voltage drops too low, the  
magnetically coupled voltage used to develop primary side voltages will also  
drop, thereby shutting down the PWM controller. Following a time-out period,  
the PWM will restart causing the output voltages to begin ramping to their  
appropriate values. If the short-circuit condition persists, another shutdown  
cycle will be initiated. This on/off cycling is referred to as "hiccup" mode. The  
hiccup cycling reduces the average output current, thereby preventing internal  
temperatures from rising to excessive levels. The UWE is capable of enduring  
an indefinite short circuit output condition.  
+SENSE  
+VOUT  
RLOAD  
SCOPE  
C1  
C2  
–VOUT  
–SENSE  
C1 = 0.47μF CERAMIC  
C2 = NA  
LOAD 2-3 INCHES (51-76mm) FROM MODULE  
Features and Options  
On/Off Control  
Figure 3. Measuring Output Ripple/Noise (PARD)  
The input-side, remote On/Off Control function can be ordered to operate with  
either logic type:  
Floating Outputs  
Since these are isolated DC-DC converters, their outputs are "floating" with  
respect to their input. Designers will normally use the –Output as the ground/  
return of the load circuit. You can, however, use the +Output as ground/return  
to effectively reverse the output polarity.  
Positive-logic models (“P" part-number suffix) are enabled when the On/Off  
Control is left open or is pulled high, as per Figure 4. Positive-logic devices are  
disabled when the On/Off Control is pulled low.  
Negative-logic devices (“N” suffix) are off when the On/Off Control is open (or  
pulled high), and on when the On/Off Control is pulled low with respect to –VIN  
as shown in Figure 5.  
Minimum Output Loading Requirements  
UWE converters employ a synchronous-rectifier design topology and all models  
regulate within spec and are stable under no-load to full load conditions.  
Operation under no-load conditions however might slightly increase the output  
ripple and noise.  
+ Vcc  
Thermal Shutdown  
ON/OFF CONTROL  
CONTROL  
These UWE converters are equipped with thermal-shutdown circuitry. If envi-  
ronmental conditions cause the internal temperature of the DC-DC converter to  
rise above the designed operating temperature, a precision temperature sensor  
will power down the unit. When the internal temperature decreases below the  
threshold of the temperature sensor, the unit will self start. See Performance/  
Functional Specifications.  
-VIN  
Output Overvoltage Protection  
UWE output voltages are monitored for an overvoltage condition via magnetic  
feedback. The signal is coupled to the primary side and if the output voltage  
rises to a level which could be damaging to the load, the sensing circuitry will  
power down the PWM controller causing the output voltages to decrease. Fol-  
lowing a time-out period the PWM will restart, causing the output voltages to  
ramp to their appropriate values. If the fault condition persists, and the output  
voltages again climb to excessive levels, the overvoltage circuitry will initiate  
another shutdown cycle. This on/off cycling is referred to as "hiccup" mode.  
Figure 4. Driving the Positive Logic On/Off Control Pin  
+ Vcc  
ON/OFF  
CONTROL  
Current Limiting  
As soon as the output current increases to substantially above its rated value,  
the DC-DC converter will go into a current-limiting mode. In this condition, the  
output voltage will decrease proportionately with increases in output current,  
thereby maintaining somewhat constant power dissipation. This is commonly  
referred to as power limiting. Current limit inception is defined as the point at  
which the full-power output voltage falls below the specified tolerance. See  
Performance/Functional Specifications. If the load current, being drawn from  
the converter, is significant enough, the unit will go into a short circuit condition  
as specified under "Performance."  
–VIN  
Figure 5. Driving the Negative Logic On/Off Control Pin  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 20 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
Dynamic control of the remote on/off function is facilitated with a mechanical  
relay or an open-collector/open-drain drive circuit (optically isolated if appropri-  
ate). The drive circuit should be able to sink appropriate current (see Performance  
Specs) when activated and withstand appropriate voltage when deactivated.  
Applying an external voltage to the On/Off Control when no input power is  
applied to the converter can cause permanent damage to the converter.  
+VOUT  
+VIN  
+SENSE  
1Mꢁ  
5-20  
TURNS  
ON/OFF  
CONTROL  
LOAD  
TRIM  
–SENSE  
–VOUT  
Trimming Output Voltage  
UWE converters have a trim capability that allows users to adjust the output  
voltages. Adjustments to the output voltages can be accomplished via a trim pot  
(Figure 6) or a single fixed resistor as shown in Figures 7 and 8. A single fixed  
resistor can increase or decrease the output voltage depending on its connec-  
tion. The resistor should be located close to the converter and have a TCR less  
than 100ppm/°C to minimize sensitivity to changes in temperature. If the trim  
function is not used, leave the trim pin floating.  
–VIN  
Figure 6. Trim Connections Using A Trimpot  
+VOUT  
+VIN  
+SENSE  
TRIM  
A single resistor connected from the Trim to the +Output, or +Sense where  
applicable, will increase the output voltage in this configuration. A resistor con-  
nected from the Trim to the –Output, or –Sense where applicable, will decrease  
the output voltage in this configuration.  
ON/OFF  
CONTROL  
LOAD  
R1  
–SENSE  
–VOUT  
Trim adjustments greater than the specified range can have an adverse  
affect on the converter's performance and are not recommended. Excessive  
voltage differences between VOUT and Sense, in conjunction with trim adjust-  
ment of the output voltage, can cause the overvoltage protection circuitry to  
activate (see Performance Specifications for overvoltage limits). Power derating  
is based on maximum output current and voltage at the converter’s output  
pins. Use of trim and sense functions can cause output voltages to increase,  
thereby increasing output power beyond the converter's specified rating or  
cause output voltages to climb into the output overvoltage region. Therefore:  
–VIN  
Figure 7. Trim Connections To Increase Output Voltages Using a Fixed Resistor  
+VOUT  
+VIN  
+SENSE  
(VOUT at pins) x (IOUT) <= rated output power  
ON/OFF  
TRIM  
–SENSE  
–VOUT  
LOAD  
CONTROL  
Note: Resistor values are in k. Adjustment accuracy is subject to resistor  
tolerances and factory-adjusted output accuracy. VO = desired output voltage.  
R2  
Remote Sense Note: The Sense and VOUT lines are internally connected  
through low value resistors. Nevertheless, if the sense function is not used for  
remote regulation the user should connect the +Sense to +VOUT and –Sense  
to –VOUT at the DC-DC converter pins.  
–VIN  
Figure 8. Trim Connections To Decrease Output Voltages  
UWE series converters have a sense feature to provide point of use regula-  
tion, thereby overcoming moderate IR drops in pcb conductors or cabling.  
The remote sense lines carry very little current and therefore require minimal  
cross-sectional-area conductors. The sense lines are used by the feedback  
control-loop to regulate the output. As such, they are not low impedance points  
and must be treated with care in layouts and cabling. Sense lines on a pcb  
should be run adjacent to dc signals, preferably ground. In cables and discrete  
wiring applications, twisted pair or other techniques should be implemented.  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 21 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
UWE series converters will compensate for drops between the output volt-  
age at the DC-DC and the sense voltage at the DC-DC provided that:  
Trim Equations  
3.3 Volt Output  
Trim Up  
Trim Down  
[VOUT(+) –VOUT(–)] –[Sense(+) –Sense (–)] 5ꢀ VOUT  
Output overvoltage protection is monitored at the output voltage pin, not  
the Sense pin. Therefore, excessive voltage differences between VOUT and  
Sense in conjunction with trim adjustment of the output voltage can cause the  
overvoltage protection circuitry to activate (see Performance Specifications  
for overvoltage limits). Power derating is based on maximum output current  
and voltage at the converter’s output pins. Use of trim and sense functions can  
cause output voltages to increase thereby increasing output power beyond the  
UWE’s specified rating or cause output voltages to climb into the output over-  
voltage region. Also, the use of Trim Up and Sense combined may not exceed  
+10ꢀ of VOUT. Therefore, the designer must ensure:  
16.31  
13.3(VO 1.226)  
VO 3.3  
10.2  
10.2  
10.2  
10.2  
10.2  
10.2  
RTDOWN (k ) =  
RTUP (k ) =  
RTUP (k ) =  
RTUP (k ) =  
RTUP (k ) =  
RTUP (k ) =  
3.3 VO  
5 Volt Output  
25.01  
20.4(VO 1.226)  
VO 5  
10.2  
RTDOWN (k ) =  
5 VO  
12 Volt Output  
60.45  
49.6(VO 1.226)  
VO 12  
10.2  
RTDOWN (k ) =  
(VOUT at pins) x (IOUT) rated output power  
12 VO  
Contact and PCB resistance  
losses due to IR drops  
15 Volt Output  
76.56  
62.9(VO 1.226)  
VO 15  
+VOUT  
+VIN  
RTDOWN (k ) =  
10.2  
15 VO  
IOUT  
+SENSE  
24 Volt Output  
Sense Current  
ON/OFF  
CONTROL  
124.2  
TRIM  
–SENSE  
–VOUT  
101(VO 1.226)  
VO 24  
LOAD  
RTDOWN (k ) =  
10.2  
24 VO  
Sense Return  
IOUT Return  
VIN  
Contact and PCB resistance  
losses due to IR drops  
Figure 9. Remote Sense Circuit Configuration  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 22 of 23  
UWE Series  
Wide Input, Isolated  
Eighth-Brick DC-DC Converters  
Vertical Wind Tunnel  
Murata Power Solutions employs a computer controlled  
custom-designed closed loop vertical wind tunnel, infrared  
video camera system, and test instrumentation for accurate  
airflow and heat dissipation analysis of power products.  
The system includes a precision low flow-rate anemometer,  
variable speed fan, power supply input and load controls,  
temperature gauges, and adjustable heating element.  
IR Transparent  
optical window  
Variable  
speed fan  
Unit under  
test (UUT)  
The IR camera monitors the thermal performance of the  
Unit Under Test (UUT) under static steady-state conditions. A  
special optical port is used which is transparent to infrared  
wavelengths.  
IR Video  
Camera  
Both through-hole and surface mount converters are  
soldered down to a 10" x 10" host carrier board for realistic  
heat absorption and spreading. Both longitudinal and trans-  
verse airflow studies are possible by rotation of this carrier  
board since there are often significant differences in the heat  
dissipation in the two airflow directions. The combination of  
adjustable airflow, adjustable ambient heat, and adjustable  
Input/Output currents and voltages mean that a very wide  
range of measurement conditions can be studied.  
Heating  
element  
Precision  
low-rate  
anemometer  
3” below UUT  
The collimator reduces the amount of turbulence adjacent  
to the UUT by minimizing airflow turbulence. Such turbu-  
lence influences the effective heat transfer characteristics  
and gives false readings. Excess turbulence removes more  
heat from some surfaces and less heat from others, possibly  
causing uneven overheating.  
Ambient  
temperature  
sensor  
Airflow  
collimator  
Both sides of the UUT are studied since there are different  
thermal gradients on each side. The adjustable heating element  
and fan, built-in temperature gauges, and no-contact IR camera mean  
that power supplies are tested in real-world conditions.  
Figure 10. Vertical Wind Tunnel  
This product is subject to the following operating requirements  
and the Life and Safety Critical Application Sales Policy:  
Refer to: http://www.murata-ps.com/requirements/  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
ISO 9001 and 14001 REGISTERED  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
notice.  
© 2015 Murata Power Solutions, Inc.  
www.murata-ps.com/support  
MDC_UWE Series.E04 Page 23 of 23  

相关型号:

UWE-15/5-Q48PB-C

DC-DC Regulated Power Supply Module,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
MURATA

UWE-24-15-Q12N-C

Wide Input, Isolated Eighth-Brick DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
MURATA

UWE-24-15-Q12NB-C

Wide Input, Isolated Eighth-Brick DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
MURATA

UWE-24-15-Q12P-C

Wide Input, Isolated Eighth-Brick DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
MURATA

UWE-24-15-Q12PB-C

Wide Input, Isolated Eighth-Brick DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
MURATA

UWE-24-15-Q48N-C

Wide Input, Isolated Eighth-Brick DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
MURATA

UWE-24-15-Q48NB-C

Wide Input, Isolated Eighth-Brick DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
MURATA

UWE-24-15-Q48P-C

Wide Input, Isolated Eighth-Brick DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
MURATA

UWE-24-15-Q48PB-C

Wide Input, Isolated Eighth-Brick DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
MURATA

UWE-24-20-Q12N-C

Wide Input, Isolated Eighth-Brick DC/DC Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 202
-
MURATA