WPN20R12S05C [MURATA]
20W Regulated DC/DC Converter; 20W稳压DC / DC转换器型号: | WPN20R12S05C |
厂家: | muRata |
描述: | 20W Regulated DC/DC Converter |
文件: | 总4页 (文件大小:188K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
WPN20
20W Regulated DC/DC Converter
SELECTION GUIDE
Input Voltage
Output Current
Input Current
Nom. Load
A
Output
Efficiency
Voltage
Order Code
Nom.
V
Min.
A
Nom.
A
V
5.0
%
84
86
86
83
84
87
87
87
85
88
87
87
12
12
12
24
24
24
24
24
48
48
48
48
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
4.00
1.66
0.83
6.00
4.00
1.66
0.83
0.67
4.00
1.66
0.83
0.67
2.00
WPN20R12S05C
WPN20R12S12C
WPN20R12D12C
WPN20R24S03C
WPN20R24S05C
WPN20R24S12C
WPN20R24D12C
WPN20R24D15C
WPN20R48S05C
WPN20R48S12C
WPN20R48D12C
WPN20R48D15C
12.0
12.0
3.3
2.00
2.00
1.00
5.0
1.00
12.0
12.0
15.0
5.0
1.00
1.00
1.00
0.50
12.0
12.0
15.0
0.50
FEATURES
ꢀRoHS compliant
0.50
0.50
ꢀOperating temperature range: -40ºC to
INPUT CHARACTERISTICS
+100ºC
Parameter
Conditions
Min.
9
Typ.
Max.
18
Units
ꢀIndustry standard pinout
ꢀInput and output filtering
ꢀLow profile shell
All WPN20R12 types
12
24
48
Voltage range
All WPN20R24 types
All WPN20R48 types
18
33
36
V
mA p-p
V
75
Reflected ripple current
50
ꢀSingle and dual outputs
ꢀOutput trim function
All WPN20R12 types
All WPN20R24 types
All WPN20R48 types
7
8.8
17
Undervoltage lockout
threshold
15.5
30
33
DESCRIPTION
OUTPUT CHARACTERISTICS
The WPN20RC series is available in three input
voltage ranges of 9-18V, 18-36V and 33-75V. The
unit is housed in a space saving aluminum shell.
The 300KHz switching frequency and forward
converter topology provide excellent performance
across all line and load conditions. Other features
include: under voltage lock-out, internal tem-
perature shutdown, soft start and over current
protection.
Parameter
Rated power
Conditions
Min.
Typ.
Max.
20
Units
W
Voltage setpoint accuracy
Temperature coefficient
1.5
%
0.005
0.1
%/ºC
%
Singles
Duals
Line regulation
Load regulation
High line to low line
0.5
%
Singles
Duals
0.5
%
Min load to
Nom. load
2.0
%
Single outputs, BW = 5Hz to 20MHz
Dual outputs, BW = 5Hz to 20MHz
See attached plots
60
50
100
100
mVp-p
mVp-p
Ripple & Noise
An output trim feature is provided, allowing the
user to compensate for long line lengths.
Output voltage adjust range
Applications include: Telecommunications, Battery
Powered Sytems, Process Control Equipment,
Transportation Equipment and Distributed Power
Systems.
Short circuit &
overcurrent protection
Continuous
GENERAL CHARACTERISTICS
Parameter
Switching frequency
Conditions
Min.
Typ.
300
550
Max.
Units
kHz
The product range has been recognised by Under-
writers Laboratory (UL) to UL 1950 for operational
insulation, file number E179522 applies.
Max capacitive load
mF/A
MTTF per ML-HDBK-217 Circuit stress method
1.4
MHr
Ground benign
TA = +25º unmodified database
All specifications typical at T =25°C, nominal input voltage and rated output current unless otherwise specified.
A
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232
KDC_WPN20RC.C01 Page 1 of 4
WPN20
20W Regulated DC/DC Converter
ISOLATION CHARACTERISTICS
Parameter
Rated voltage
Conditions
Min.
1500
1500
10
Typ.
Max.
Units
Vpk
Vpk
GΩ
Test voltage
60Hz, 10 seconds
Resistance
Capacitance
2400
pF
TEMPERATURE CHARACTERISTICS
Parameter
Specification
Operation
Conditions
Case
Min.
Typ.
Max.
+85
Units
°C
-40
-40
-55
105
Case
+85
°C
Storage
+125
115
°C
Thermal shutdown
Case
°C
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC
for 10 seconds. The pin termination finish on this product series is matte tin (100 microns min.) over
nickel (40-80 microinches min.). The series is backward compatible with Sn/Pb soldering systems.
For further information, please visit www.murata-ps.com/rohs
THERMAL DERATING CURVE
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions WPN20 series of dc/dc converters are all 100% production tested at their stated isolation voltage. This is 1500 Vpk for 10 seconds.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The WPN20 series has been recognized by Underwriters Laboratory, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC.
The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be
expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded
as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard
requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materi-
als, construction and environment. While manufactured parts can withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any
material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of
tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from
specified test voltage.
www.murata-ps.com
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232
KDC_WPN20RC.C01 Page 2 of 4
WPN20
20W Regulated DC/DC Converter
PERFORMANCE GRAPHS
EFFICIENCY VS. OUTPUT LOAD
EFFICIENCY VS. TEMPERATURE
15V
12V
5V
90
85
80
75
70
65
60
55
50
10
5
3V
100% Load
20% Load
0
-5
-10
10
20
40
50
60
80
100
-40
-15
25
65
110
Output Load (% or Rated)
Tcase (C)
50%Load
10%Load
100%Load
EFFICIENCY VS. INPUT VOLTAGE
OUTPUT RIPPLE VS. INPUT VOLTAGE
0.6
0.4
0.2
0
1.4
1.2
1
-0.2
-0.4
-0.6
-0.8
-1
0.8
0.6
0.4
LL
Nom
HL
LL
Nom
HL
Vin
Vin
5
5
TRIM RESISTOR VS. OUTPUT VOLTAGE CHANGE
50
3
-trim +trim
OUTPUT RIPPLE VS. TEMPERATURE
1.2
1
45
40
35
30
25
20
15
10
5
0.8
0.6
-40
-15
25
65
110
0
10
9
8
7
6
5
4
3
2
1
Tcase (C)
Percentage Change In Output Voltage
12 15 15
TRIM RESISTOR VS. OUTPUT VOLTAGE CHANGE
+trim -trim trim
100
90
80
70
60
50
40
30
20
10
0
10
9
8
7
6
5
4
3
2
1
Percentage Change In Output Voltage
www.murata-ps.com
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232
KDC_WPN20RC.C01 Page 3 of 4
WPN20
20W Regulated DC/DC Converter
MECHANICAL DIMENSTIONS
PIN SIDE DOWN
SIDE VIEW
0.425 0.00
(10.80 0.08ꢀ
0.150
(3.81ꢀ
0.040 0.002
(1.02 0.05ꢀ
0.015 0.003
WPN20RxxyzzC
(0.38 0.08ꢀ
5
6
7
8
1.990 0.005
(50.55 0.13ꢀ
1
2
PIN CONNECTIONS
Function
Pin
PIN SIDE UP
Singles
+VIN
Duals
+VIN
-VIN
1
2
5
6
7
8
-VIN
NO PIN
+VOUT
-VOUT
+VOUT
OV
-VOUT
TRIM
TRIM
Weight: 32g
All pins on a 0.1 (2.54) pitch and within 0.01 (0.25) of true position.
Unless otherwise stated all dimensions are in inches (mm) 0.01 (0.25).
USA:
Mansfield (MA), Tel: (508) 339 3000, email: sales@murata-ps.com
Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com
Murata Power Solutions, Inc.
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Germany: München, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 & ISO 14001 REGISTERED
Japan:
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com
China:
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com
notice.
© 2009 Murata Power Solutions, Inc.
www.murata-ps.com
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232
KDC_WPN20RC.C01 Page 4 of 4
相关型号:
©2020 ICPDF网 联系我们和版权申明