ARA220A4H [NAIS]

MICROWAVE RELAY FOR ATTENUATOR CIRCUIT; 微波中继衰减器电路
ARA220A4H
型号: ARA220A4H
厂家: NAIS(MATSUSHITA ELECTRIC WORKS)    NAIS(MATSUSHITA ELECTRIC WORKS)
描述:

MICROWAVE RELAY FOR ATTENUATOR CIRCUIT
微波中继衰减器电路

继电器 微波 光电二极管 衰减器
文件: 总3页 (文件大小:205K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MICROWAVE RELAY  
FOR ATTENUATOR  
CIRCUIT  
RA-RELAYS  
• Insertion loss; Max. 0.3dB  
• Isolation; Min. 20dB (Between open  
contacts)  
line in the base circuit design which  
spares the labor of machining the base.  
3. Low profile small type  
9.7  
.382  
14.70  
.579  
5.9  
.232  
Min. 30dB (Between contact  
sets)  
V.S.W.R.; Max. 1.2  
2. Surface mount terminal  
This relay is a surface-mounted model  
with excellent high-frequency proper-  
ties. In addition, it can use a microstrip  
9.7(W)×14.7(L)×5.9(H) mm  
.382(W)×.579(L)×.232(H) inch  
4. High sensitivity: 140 mW nominal  
operating power  
5. High contact reliability  
Electrical life: Min. 107 (10mA 10V DC)  
mm inch  
FEATURES  
1. High frequency characteristics  
(Impedance 50, ~1.0GHz)  
SPECIFICATIONS  
Contact  
Arrangement  
Characteristics  
Initial insulation resistance *1  
2 Form C  
Gold-clad silver alloy  
Max. 75mΩ  
Min. 100 M(at 500 V DC)  
Contact material  
Between open con-  
tacts  
750 Vrms for 1 min.  
Initial contact resistance  
Between contact  
sets  
10mA 10 V DC  
1A 30 V DC  
1,000 Vrms for 1 min.  
1,000 Vrms for 1 min.  
1,000 Vrms for 1 min.  
Contact rating (resistive)  
Initial breakdown  
voltage *2  
Between contact  
and coil  
Max. 3W(at 1.0GHz, imped-  
ance 50, V.S.W.R. max.1.2)  
Contact carrying power  
Rating  
Between contact  
and earth terminal  
Max. switching voltage  
Max. switching current  
30 V DC  
1A  
Max. 4ms (Approx. 2ms)  
[Max. 4ms (Approx. 2ms)]  
Operate time [Set time] *3 (at 20°C)  
Between  
open con-  
Min. 20dB  
Min. 30dB  
Release time (without diode) [Reset time]  
Max. 4ms (Approx. 1ms)  
[Max. 4ms (Approx. 2ms)]  
tacts  
High fre-  
quency  
character-  
istics  
(~1GHz,  
Imped-  
ance 50)  
*3(at 20°C)  
Isolation  
Between  
Temperature rise (at 20°C) *4  
Max. 60°C  
500 m/s2  
1,000 m/s2  
contact  
sets  
Functional *5  
Destructive *6  
Shock resistance  
Insertion loss  
V.S.W.R.  
Max. 0.3dB  
Max. 1.2  
10 to 55 Hz at double  
amplitude of 3mm  
Functional *7  
Vibration resistance  
Max. 3W(at 1.0GHz, imped-  
ance 50, V.S.W.R. max.1.2)  
Input power  
10 to 55 Hz at double  
amplitude of 5mm  
Destructive  
140mW (1.5 to 12V)  
200mW (24V)  
Single side stable  
1 coil latching  
Conditions for oper-  
Ambient temp  
–40°C to +85°C  
–40°F to +185°F  
300mW (48V)  
ation, transport and  
Nominal  
operating  
power  
storage *8  
70 mW (1.5 to 12V)  
100mW (24V)  
(Not freezing and  
condensing at low  
temperature)  
Humidity  
5 to 85% R.H.  
140mW (1.5 to 12V)  
200mW (24V)  
2 coil latching  
Unit weight  
Approx. 2g .07oz  
Mechanical (at 180 cpm)  
108  
Remarks  
10mA 10 V  
DC(resis-  
* Specifications will vary with foreign standards certification ratings.  
*1 Measurement at same location as “Initial breakdown voltage” section.  
*2 Detection current: 10mA  
*3 Nominal operating voltage applied to the coil, excluding contact bounce time.  
*4 By resistive method, nominal voltage applied to the coil: 3W contact carrying  
power: at 1.0GHz, Impedance 50, V.S.W.R. Max.1.2  
*5 Half-wave pulse of sine wave: 11ms, detection time: 10µs.  
*6 Half-wave pulse of sine wave: 6ms  
Expected  
life (min.  
operation)  
107  
tive load)  
Electrical  
(at 20 cpm)  
1A 30 V DC  
(resistive  
load)  
105  
*7 Detection time: 10µs  
*8 Refer to 5. Conditions for operation, transport and storage mentioned in  
AMBIENT ENVIRONMENT (Page 61)  
TYPICAL APPLICATIONS ORDERING INFORMATION  
• Measurement instruments  
Ex.  
A
RA  
2
0
0
A
03  
Oscilloscope attenuator circuit  
Product name Contact arrangement Operating function Type of operation Terminal shape Coil voltage, V DC  
0: Single side stable 0: Standard A: Surface-mount  
RA  
2: 2 Form C  
1H: 1.5 09: 9  
03: 3 12: 12  
4H: 4.5 24: 24  
1: 1 coil latching  
2: 2 coil latching  
type  
(B.B.M)  
terminal  
05: 5  
06: 6  
48: 48  
Note: Standard packing; Carton: 40 pcs. Case 1,000 pcs.  
80  
RA  
TYPES ANE COIL DATA (at 20°C 68°F)  
• Single side stable type  
Nominal  
voltage,  
V DC  
Pick-up voltage,  
V DC (max.)  
(initial)  
Drop-out  
voltage, V DC  
(min.)(initial)  
Nominal  
Nominal  
Coil resistance,  
Max. allowable  
voltage, V DC  
Part No.  
operating current, operating power,  
(±10%)  
mA (±10%)  
93.8  
mW  
140  
140  
140  
140  
140  
140  
140  
200  
300  
ARA200A1H  
ARA200A03  
ARA200A4H  
ARA200A05  
ARA200A06  
ARA200A09  
ARA200A12  
ARA200A24  
ARA200A48  
01.5  
03.0  
04.5  
05.0  
06.0  
09.0  
12.0  
24.0  
48.0  
1.125  
2.250  
0.15  
0.30  
0.45  
0.50  
0.60  
0.90  
1.20  
2.40  
4.80  
00.16.0  
00.64.3  
0.1450  
0.1780  
0.2570  
0.5790  
1,028.0  
2,880.0  
7,680.0  
2.25  
4.50  
46.7  
3.375  
31.0  
6.75  
3.750  
28.1  
7.50  
4.500  
23.3  
90.0  
6.750  
15.5  
13.50  
180.0  
360.0  
57.60  
90.00  
11.7  
18.0000  
36.0000  
08.3  
06.3  
• 1 coil latching type  
Nominal  
voltage,  
V DC  
Set voltage,  
V DC (max.)  
(initial)  
Reset voltage,  
V DC (max.)  
(initial)  
Nominal  
Nominal  
Coil resistance,  
Max. allowable  
voltage, V DC  
Part No.  
operating current, operating power,  
(±10%)  
mA (±10%)  
mW  
070  
070  
070  
070  
070  
070  
070  
100  
ARA210A1H  
ARA210A03  
ARA210A4H  
ARA210A05  
ARA210A06  
ARA210A09  
ARA210A12  
ARA210A24  
01.5  
03.0  
04.5  
05.0  
06.0  
09.0  
12.0  
24.0  
1.125  
2.250  
3.375  
3.750  
4.500  
6.750  
9.000  
18.000  
01.125  
02.250  
03.375  
03.750  
04.500  
06.750  
09.000  
18.000  
0.032.0  
0.128.6  
0.289.3  
0.357.0  
0.514.0  
1,157.0  
2,057.0  
5,760.0  
46.9  
2.25  
4.50  
23.3  
15.6  
6.75  
14.0  
7.50  
11.7  
9.00  
07.8  
13.50  
18.00  
36.00  
05.8  
04.2  
• 2 coil latching type  
Nominal  
voltage,  
V DC  
Set voltage,  
V DC (max.)  
(initial)  
Reset voltage,  
V DC (max.)  
(initial)  
Nominal  
Nominal  
Coil resistance,  
Max. allowable  
voltage, V DC  
Part No.  
operating current, operating power,  
(±10%)  
mA (±10%)  
mW  
140  
140  
140  
140  
140  
140  
140  
200  
ARA220A1H  
ARA220A03  
ARA220A4H  
ARA220A05  
ARA220A06  
ARA220A09  
ARA220A12  
ARA220A24  
01.5  
03.0  
04.5  
05.0  
06.0  
09.0  
12.0  
24.0  
01.125  
02.250  
03.375  
03.750  
04.500  
06.750  
09.000  
18.000  
01.125  
02.250  
03.375  
03.750  
04.500  
06.750  
09.000  
18.000  
.0016.0  
.0064.3  
.0145.0  
.0178.0  
.0257.0  
.0579.0  
1,028.0  
2,880.0  
93.8  
2.25  
4.50  
46.7  
31.0  
6.75  
28.1  
7.50  
23.3  
9.00  
15.5  
13.50  
18.00  
36.00  
11.7  
08.3  
mm inch  
DIMENSIONS  
Suggested Mounting Pads (Top view)  
Single side stable  
1 coil latching  
2 coil latching  
14.0  
.551  
14.0  
.551  
14.30  
.563  
12.90  
.508  
1.0  
1.0  
2.54  
.100  
2.00  
.079  
14.0  
.551  
1.0  
2.54  
.100  
2.00  
.079  
.039  
2.54  
.100  
.039  
.039  
2.94  
.116  
2.00  
.079  
2.94  
.116  
2.94  
.116  
9.56  
9.56  
.376  
8.90  
.350  
8.90  
.350  
9.56  
.376  
.376  
12.50  
.492  
8.90  
.350  
0.3  
.012  
12.50  
.492  
0.3  
.012  
12.50  
.492  
0.3  
.012  
for glue pad  
earth  
for glue pad  
earth  
9.70  
.382  
for glue pad  
earth  
14.70  
.579  
2.00  
.079  
12.40  
.488  
2.00  
.079  
14.90  
.587  
2.00  
.079  
12.40  
.488  
0.25  
.010  
0~0.30  
0~.012  
5.90  
.232  
14.90  
.587  
14.90  
.587  
7.62  
.300  
11.5±0.5  
.453±.020  
0.50  
.020  
Tolerance: ±0.1 ±.004  
2.54  
.100  
Soldering with  
PC board earth  
(4 ribs)  
Schematic (Top view)  
1 coil latching  
2 coil latching  
Single side stable  
10 9  
8
7
6
Tolerance: ±0.3 ±.012  
10 9  
8
7
6
10  
9
8
7
6
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
Direction indication  
(Reset condition)  
(Reset condition)  
(Deenergized condition)  
81  
RA  
REFERENCE DATA  
1. High frequency characteristics  
Sample: ARA200A12  
Measuring method: Measured with HP network analyzer (HP8753C).  
• Insertion loss  
• Isolation  
• V.S.W.R.  
0
0
1.5  
COM-NO  
COM-NC  
COM-NC  
COM-NO  
0.2  
0.3  
0.4  
20  
30  
40  
1.4  
1.3  
CONTACT sets  
0.6  
0.8  
60  
80  
1.2  
1.1  
COM-NC  
0.5GHz  
100  
300kHz  
COM-NO  
1.0  
300kHz  
1.0  
0.5GHz  
Frequency  
1.0GHz  
0.5GHz  
Frequency  
1.0GHz  
300kHz  
1.0GHz  
Frequency  
NOTES  
1. Coil operating power  
1) Position of measuring temperature  
Pure DC current should be applied to the  
coil. The wave form should be rectangu-  
lar. If it includes ripple, the ripple factor  
should be less than 5%.  
B
1.0mm .039inch  
A
However, check it with the actual circuit  
since the characteristics may be slightly  
different. The nominal operating voltage  
should be applied to the coil for more  
than 10 ms to set/reset the latching type  
relay.  
A: Surface of PC board where relay is mounted.  
B: Above the PC board surface.  
2) IR (infrared reflow) soldering method  
A:  
B:  
2. Coil connection  
T
T5  
4
When connecting coils, refer to the wiring  
diagram to prevent mis-operation or mal-  
function.  
T
3
T
T2  
1
3. External magnetic field  
Since RA relays are highly sensitive po-  
larized relays, their characteristics will be  
affected by a strong external magnetic  
field. Avoid using the relay under that  
condition.  
t
1
t
2
t
3
t
4 t5  
T1  
T2  
T3  
T4  
T5  
=150°C 302°F  
=160°C 320°F  
=183°C 361°F  
=245°C 473°F  
=270°C 518°F  
t
t
t
2
5
4
- t  
- t  
1
= 80 to 120 s  
3 = 30 to 40 s  
= 170 to 190 s  
4. Cleaning  
Temperature rise of relay itself may vary  
according to the mounting level or the  
heating method of reflow equipment.  
Therefore, please set the temperature of  
soldering portion of relay terminal and  
the top surface of the relay case not to  
exceed the above mentioned soldering  
condition.  
It is recommended to check the tempera-  
ture rise of each portion under actual  
mounting condition before use.  
The soldering earth shall be performed  
by manual soldering.  
For automatic cleaning, the boiling meth-  
od is recommended. Avoid ultrasonic  
cleaning which subjects the relays to high  
frequency vibrations, which may cause  
the contacts to stick.  
It is recommended that alcoholic solvents  
be used.  
5. Soldering  
Manual soldering shall be performed un-  
der following condition.  
Tip temperature: 280°C to 300°C .536°F  
to 572°F  
Wattage: 30 to 60W  
Soldering time: within 5s  
In case of automatic soldering, the follow-  
ing conditions should be observed  
For Cautions for Use, see Relay Technical Information (Page 48 to 76).  
9/1/2000  
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.  
Go To Online Catalog  

相关型号:

ARA220A4HX

RF Relay, 2 Form C, DPDT, Latched, 0.031A (Coil), 4.5VDC (Coil), 140mW (Coil), 1A (Contact), 30VDC (Contact), 1000MHz, 3W (RF Input), DC Input, Random, DC Output, Surface Mount-Straight
PANASONIC

ARA220A4HZ

RF Relay, 2 Form C, DPDT, Latched, 0.031A (Coil), 4.5VDC (Coil), 140mW (Coil), 1A (Contact), 30VDC (Contact), 1000MHz, 3W (RF Input), DC Input, Random, DC Output, Surface Mount-Straight, ROHS COMPLIANT
PANASONIC

ARA3000S23

Telephony Reverse Amplifier With Step Attenuator
ANADIGICS

ARA502-1122S

Telecom and Datacom Connector, 8 Contact(s), Male, Right Angle, Solder Terminal, Locking, Jack, ROHS COMPLIANT
ALLIED

ARA506-3002I

Telecom and Datacom Connector, ROHS COMPLIANT
ALLIED

ARA506-3002S

Telecom and Datacom Connector, ROHS COMPLIANT
ALLIED

ARA506-LJ02I

Telecom and Datacom Connector, ROHS COMPLIANT
ALLIED

ARA506-LJ02S

Telecom and Datacom Connector, ROHS COMPLIANT
ALLIED

ARA508-0145S

Telecom and Datacom Connector, ROHS COMPLIANT
ALLIED

ARA50B105KGS

CAP,CERAMIC,1UF,50VDC,10% -TOL,10% +TOL,X7R TC CODE,-15,15% TC
KEMET

ARA50B105KWS

Ceramic Capacitor, Ceramic, 50V, 10% +Tol, 10% -Tol, X7R, 15% TC, 1uF, Through Hole Mount, 5227, AXIAL LEADED
KEMET

ARA50B684KGS

CAP,CERAMIC,680NF,50VDC,10% -TOL,10% +TOL,X7R TC CODE,-15,15% TC
KEMET