JV1A-6V [NAIS]
FLAT TYPE POWER RELAY; 扁平型功率继电器型号: | JV1A-6V |
厂家: | NAIS(MATSUSHITA ELECTRIC WORKS) |
描述: | FLAT TYPE POWER RELAY |
文件: | 总4页 (文件大小:63K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
FLAT TYPE POWER RELAY
JV-RELAYS
22
.866
16
.630
FEATURES
• Flat type: 16 mm (length) × 22 mm (width) × 10.9 mm (height)
(.630×.866×.429 inch)
10.9
.429
• High capacity type (16A) available
• High sensitivity type (100 mW: 1 Form A) available
• TÜV also approved
mm inch
SPECIFICATIONS
Contact
Characteristics
High capacity
type
High
sensitivity type
Standard type
Max. operating speed
20 cpm
Arrangement
1 Form A
1 Form C
50 mΩ
Silver alloy
1 Form A
1 Form A
Initial insulation resis-
tance*1
Min. 100 MΩ
(at 500 V DC)
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Betweenopen
contacts
1,000 Vrms
for 1 min.
Initial
Contact material
break-
down
voltage*2
Between con-
tacts and coil
1,500 Vrms
for 1 min.
Nominal switching
capacity
10 A 125 V AC (N.O.)
6 A 125 V AC (N.C.)
10 A 125 V AC
1,250 VA
16 A 125 V AC 10 A 125 V AC
Approx. 10 ms
Approx. 5 ms
(100 V DC coil type)
1,250 VA (N.O.)
750 VA (N.C.)
Operate time*3
(at nominal voltage)
Max. switching power
Max. switching voltage
Max. switching current
2,000 VA
16 A
1,250 V
10 A
Rating
(resistive)
125 V AC
Release time (without diode)*3
(at nominal voltage)
10 A (N.O.)
6 A (N.C.)
Approx. 4 ms
10 A
Max. 65°C with nominal
coil voltage across
coil and at nominal
switching capacity
Expected life (min. ope.)
Mechanical at (180 cpm)
107
Temperature rise
(at 50°C)
Sealed type
105
105
105
3×104
5×104
Electrical at resistive
(at 20 cpm)
(at rated load)
Functional*4
Shock
Min. 98 m/s2 {10 G}
Flux-resistant
type
3×105
105
105
Min. 980 m/s2
{100 G}
Destructive*5
resistance
Coil
1 Form A type
1 Form C type
10 to 55 Hz
400 mW (up to 48 V coil type)
600 mW (100 V coil type)
Standard type
Functional*6 at double amplitude
of 1.0 mm
200 mW (up to 48 V coil type)
600 mW (100 V coil type)
Nominal
operating
power
Vibration
resistance
High capacity type
High sensitivity type
—
—
10 to 55 Hz
at double amplitude
of 1.6 mm
100 mW
Destructive
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage"section
*2 Detection current: 10mA
Conditions for opera- Ambient –40°C to +70°C*8
tion, transport and
temp.
–40°F to +158°F
storage*7
*3 Excluding contact bounce time
(Not freezing and
condensing at low
temperature)
*4 Half-wave pulse of sine wave: 11ms, detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10µs
Humidity
5 to 85%R.H.
*
7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
Unit weight
Approx. 8 g .282 oz
*8 100V type: –40 to + 60°C –40 to + 140°F
TYPICAL APPLICATIONS
1. Home appliances: Air conditioner, heater, etc.
2. Automotive: Power supply for car stereo and air conditioner
ORDERING INFORMATION
Ex. JV
1a
P
F
S
12V
Contact arrangement
Rating
Protective construction
Sensitivity
Nil: Standard type
Coil voltage (DC)
(1 Form A: 200 mW, 1Form C: 400 mW
100 V DC coil type: 600 mW)
S: High sensitivity type*
5, 6, 9, 12, 18,
24, 48, 100V
1: 1 Form C
1a: 1 Form A
Nil: Standard type
P: High capacity type*
Nil: Sealed type
F: Flux-resistant type
(1 Form A: 100 mW)
Notes: 1. Standard packing: Carton: 50 pcs.; Case: 1,000 pcs.
2. Coil voltage DC 48, 100 V types are not available for high sensitivity type.
UL/CSA, TÜV approved type is standard.
* Only for 1 Form A type
87
JV
TYPES
Part No.
Flux-resistant type
Contact arrangement
Coil voltage, V DC
Sealed type
JV1a-5V
5
6
JV1aF-5V
JV1aF-6V
JV1a-6V
9
JV1a-9V
JV1aF-9V
12
18
24
48
100
5
JV1a-12V
JV1a-18V
JV1a-24V
JV1a-48V
JV1a-100V
JV1aP-5V
JV1aP-6V
JV1aP-9V
JV1aP-12V
JV1aP-18V
JV1aP-24V
JV1aP-48V
JV1aP-100V
JV1aS-5V
JV1aS-6V
JV1aS-9V
JV1aS-12V
JV1aS-18V
JV1aS-24V
JV1-5V
JV1aF-12V
JV1aF-18V
JV1aF-24V
JV1aF-48V
JV1aF-100V
JV1aPF-5V
JV1aPF-6V
JV1aPF-9V
JV1aPF-12V
JV1aPF-18V
JV1aPF-24V
JV1aPF-48V
JV1aPF-100V
JV1aFS-5V
JV1aFS-6V
JV1aFS-9V
JV1aFS-12V
JV1aFS-18V
JV1aFS-24V
JV1F-5V
1 Form A
Standard type
6
9
12
18
24
48
100
5
1 Form A
High capacity type
6
9
1 Form A
High sensitivity type
12
18
24
5
6
JV1-6V
JV1F-6V
9
JV1-9V
JV1F-9V
12
18
24
48
100
JV1-12V
JV1F-12V
1 Form C
JV1-18V
JV1F-18V
JV1-24V
JV1F-24V
JV1-48V
JV1F-48V
JV1-100V
JV1F-100V
COIL DATA (at 20°C 68°F)
Drop-out
voltage,
V DC (min.)
Nominal operat-
ing current, mA operating power,
Nominal
Max. allowable
voltage,
Nominal voltage, Pick-up voltage,
Coil resistance,
Part No.
V DC
V DC (max.)
Ω (±10%)
(±10%)
40
mW
200
200
200
200
200
200
200
600
100
100
100
100
100
100
400
400
400
400
400
400
400
600
V DC
5
6
4.0
4.8
0.25
0.3
0.45
0.6
0.9
1.2
2.4
3
125
180
7.5
9
33.3
22.2
16.7
11.1
8.3
9
7.2
405
13.5
18
1 Form A
(Standard type &
High capacity
type)
12
18
24
48
100
5
9.6
720
14.4
19.2
38.4
48
1,620
2,880
11,520
16,600
250
27
36
4.2
72
6
110
9
4.0
0.25
0.3
0.45
0.6
0.9
1.2
0.25
0.3
0.45
0.6
0.9
1.2
2.4
5
20
6
4.8
360
16.7
11.1
8.3
10.8
16.2
21.6
32.4
43.2
6.5
1 Form A
(High sensitivity
type)
9
7.2
810
12
18
24
5
9.6
1,440
3,240
5,760
62.5
14.4
19.2
4.0
5.6
4.2
80
6
4.8
90
66.7
44.4
33.3
22.2
16.7
8.3
7.8
9
7.2
202.5
360
11.7
15.6
23.4
31.2
62.4
110
12
18
24
48
100
9.6
1 Form C
14.4
19.2
38.4
70
810
1,440
5,760
16,600
6
88
JV
mm inch
DIMENSIONS
1 Form A type
1 Form C type
22
16
22
16
.630
.866
.630
.866
10.5
10.5
0.4
0.4
.413
.413
.016
.016
4
4
.157
.157
17.78
.700
PC board pattern (Copper-side view)
17.78
.700
PC board pattern (Copper-side view)
17.78
.700
2-0.9 dia.
2-.035 dia.
17.78
.700
2-0.9 dia.
2-.035 dia.
2
1
2
1
12.7
.500
12.7
.500
COM
3
NO
4
NC
5
COM
3
NO
NC
5
12.7
.500
12.7
.500
4
10.16
10.16
.400
7.62
.300
.400
2-1.3 dia.
3-1.3 dia.
2-.051 dia.
3-.051 dia.
10.16
.400
10.16
.400
7.62
.300
Dimension :
Max. 1mm .039 inch
General tolerance
±0.2 ±.008
Dimension :
Max. 1mm .039 inch
General tolerance
±0.2 ±.008
1 to 5mm .039 to .197 inch ±0.3 ±.012
Min. 5mm .197 inch ±0.4 ±.016
1 to 5mm .039 to .197 inch ±0.3 ±.012
Min. 5mm .197 inch ±0.4 ±.016
Tolerance: ±0.1 ±.004
Tolerance: ±0.1 ±.004
REFERENCE DATA
1.-(1) Maximum value for switching capacity
1.-(2) Maximum value for switching capacity
(1 Form C type)
2.-(1) Operate/release time
(Standard 1 Form A type)
(1 Form A type)
100
100
18
16
14
High capacity type, AC resistive load
16
AC resistive load (NO side)
10
10
Standard type, AC resistive load
12
Operate time
10
8
1
1
6
Max.
–
x
4
2
Min.
Release time
Max.
–
x
Min.
10
100
1,000
10
100
1,000
0
80
100
120 140 160 180
Contact voltage, V
Contact voltage, V
Coil applied voltage, %V
2.-(2) Operate/release time
(High capacity 1 Form A type)
2.-(3) Operate/release time (1 Form C type)
3.-(1) Coil temperature rise (1 Form A type)
Measured portion: Inside the coil
15 A at 26°C 79°F
18
16
14
12
10
(High capacity type)
80
10
10 A at
15°C 59°F
(Standad type)
15 A at 60°C 140°F
(High capacity type)
8
60
40
20
Operate time
10 A at
60°C 140°F
(Standad type)
6
Operate time
8
Max.
4
2
–
x
6
Min.
Max.
–
x
Release time
Max.
4
–
x
Min.
Release time
2
Max.
Min.
–
x
Min.
0
0
80 100 120 140 160 180
0
80
100
120 140 160
80 100 120 140 160 180
Coil applied voltage, %V
Coil applied voltage, %V
Coil applied voltage, %V
3.-(2) Coil temperature rise
(1 Form C type)
Measured portion: Inside the coil
3.-(3) Coil temperature rise
(High sensitivity type)
Measured portion: Inside the coil
4. Life curve
Operation frequency: 20 times/min.
(ON/OFF = 1.5s:1.5s)
Ambient temperature: Room temperature
100
60
Standard 200 mW type
125V AC resistive load
80
60
40
20
10 A
at 25°C 77°F
40
10
High sensitivity 100 mW type
20
0
1
0
80 100 120 140 160 180
Coil applied voltage, %V
0 100
120
140
160 180
200
4
6
8
10 12 14 16 18
Contact current, A
Coil applied voltage, %V
89
JV
5.-(1) Ambient temperature characteristics
(Standard 10 A type, 1 Form A)
Contact current: 10 A
5.-(2) Ambient temperature characteristics
(High capacity 15 A type, 1 Form A)
Contact current: 0 A, 10 A, 13 A, 15 A
5.-(3) Ambient temperature characteristics
(1 Form C type)
Contact current: 10 A
Allowable ambient temperatures
against % coil voltages
Allowable ambient temperatures
against % coil voltage
300
300
(max. inside the coil temperature
(max. inside the coil temperature
set as 115°C 239°F)
set as 115°C 239°F)
200
Allowable ambient
temperature against
200
200
% coil voltages
Pick-up voltage with
a hot-start condition
of 100%V on the coil
(max. inside the coil
Pick-up voltage
temperature set as
15 A
13 A
115°C 239°F)
100
Pick-up voltage with
a hot-start condition
of 100%V on the coil
100
100
Pick-up voltage
10 A Pick-up voltage
0 A
0
20
40
60 80 100 120
0
20
40
60
80
0
20
40
60 80 100 120
Ambient temperature, °C
Ambient temperature, °C
Ambient temperature, °C
5.-(4) Ambient temperature characteristics
(High sensitivity type)
Contact current: 10 A
300
High sensitivity
100 mW type
Standard
200 mW type
Allowable ambient
temperature
200
100
against % coil
voltages (max.
inside the coil temperature
set as 115°C 239°F)
0
0
20
40
60
80
100
120
Temperature rise, °C
Types dedicated to a wider variety of automotive applications are available, upon receipt of order, with the following specifications:
SPECIFICATIONS
Contact
Characteristics
Arrangement
1 Form C
100 mΩ
Max. operating speed
Initial insulation resistance
20 cpm
Min. 100 MΩ (at 500 V DC)
750 Vrms for 1 min.
1,500 Vrms for 1 min.
Approx. 5 ms
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Between open contacts
Initial break
Contact material
Silver alloy
down voltage
Between contacts and coil
10 A 125 V AC
6A 30 V DC
Operate time (at nominal voltage)
Release time (at nominal voltage)
Nominal switching capacity
Approx. 4 ms
Rating
(resistive
load)
1,250 V AC
180 W
Max. switching power
Temperature rise (max.)
(at nominal voltage)(at 50°C)
65°C with nominal coil voltage and at
maximum allowable contact current
Max. switching voltage
Max. switching current
Mechanical (at 300 cpm)
125 V (AC) 30 V (DC)
10 A (AC) 6 A (DC)
5×106
Functional
Shock resistance
Min. 196 m/s2 {20 G}
Min. 980 m/s2 {100 G}
Destructive
Expected
life (min.
ope.)
10 to 55 Hz at double amplitude of
1.6 mm
Functional
Vibration resistance
Destructive
Electrical
(DC 12 V motor, 6 A steady current,
20 A lock current)(at rated load)
4×104
10 to 55 Hz at double amplitude of
2 mm
Coil
Conditions for operation,
transport and storage
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
–40°C to +70°C
–40°F to +158°F
Nominal voltage, V DC
5, 6, 9, 12, 18, 24
450 mW
Nominal operating power
Pick-up voltage, V DC (max.)
Drop-out voltage; V DC (min.)
Max. allowable voltage
Humidity
5 to 85%R.H.
70% of nominal voltage
5% of nominal voltage
150% of nominal voltage
Unit weight
Approx. 8 g .282 oz
For Cautions for Use, see Relay Technical Information (Page 11 to 39).