UA2-3NJ-L [NEC]
Super-compact size, Slim-package, Surface mounting type; 超紧凑的尺寸,超薄封装,表面贴装型型号: | UA2-3NJ-L |
厂家: | NEC |
描述: | Super-compact size, Slim-package, Surface mounting type |
文件: | 总12页 (文件大小:129K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DATA S HEET
MINIATURE SIGNAL RELAY
UA2/ UB2 SERIES
Super-com pact size, Slim -package, Surface m ounting type
DESCRIPTION
NEC's UA2/UB2 relay ia a new generation Miniature Signal Relay of super-com pact size and slim -pakage.
But, the latching type production is going to start after J une 2000.
FEATURES
™ Sm all m ounting size of slim package for dense m ounting.
™ Bellcore (2500 V) and FCC (1500 V) surge capability.
™ IEC950/UL1950/EN60950 spacing and high breakdown voltage.
(Basic insulation class on 200 V working voltage)
™ Low power consum ption 140 m W
APPLICATIONS
Electronic switching system s, PBX, term inal equipm ent, telephone system , instrum ental equipm ent.
For Right Use of Miniature Relays
DO NOT EXCEED MAXIMUM RATINGS.
Do not use relays under exceeding conditions such as over am bient tem perature, over voltage
and over current. Incorrect use could result in abnorm al heating, dam age to related parts or
cause burning.
READ CAUTIONS IN THE SELECTION GUIDE.
Read the cautions described in NEC's "Miniature Relays" (ER0046EJ ) when you choose relays
for your application.
The inform ation in this docum ent is subject to change w ithout notice.
Docum ent No. ER0450EJ 2V0DS00 (2nd edition)
Date Published J anuary 2000 M
Printed in J apan
©
1999
UA2/ UB2 SERIES
DIMENSIONS AND PAD LAYOUTS (Unit : m m [inch])
UA2 SERIES
mm [inch]
(mm)
7.6
10.6 [0.417]
5.7 [0.224]
φ
8 - 0.85
3.2 2.2 2.2
(Bottom view )
(1.5)
(1.5)
3.2
3.2
2.2 2.2
[0.126]
Note. General tolerance : ±0.1
[0.126] [0.087][0.087]
Tolerance of lead pitch is ±0.15 mm [0.006 inch]
Another tolerance is ±0.3 mm [0.012 inch]
( ) is reference.
Value of trimmed lead type (NJ type)
UB2 SERIES
7.6
mm [inch]
(mm)
3.2
2.2 2.2
10.6 [0.417]
5.7 [0.224]
0.8
(1.5)
(1.5)
3.2 [0.126]
3.2
2.2
2.2
[0.126] [0.087][0.087]
7.4 [0.291]
6.0 [0.236]
(Bottom view )
Tolerance of lead pitch is ±0.15 mm [0.006 inch]
Another tolerance is ±0.3 mm [0.012 inch]
( ) is reference.
Note. General tolerance : ±0.1
Value of minimum footprint type (NUN type)
2
DATA SHEET ER0450EJ2V0DS00
UA2/ UB2 SERIES
PIN CONFIGURATIONS (bottom view)
UA2 SERIES
1
8
2
7
3
6
4
5
1
8
2
7
3
6
4
5
R
S
Index mark of
relay direction
Non-latch type
(not energized position)
Single coil latch type
(reset position)
S : Coil polarity of set (operate)
R : Coil polarity of reset (release)
UB2 SERIES
1
8
2
7
3
6
4
5
1
8
2
7
3
6
4
R
S
Index mark of
relay direction
5
Non-latch type
(not energized position)
Single coil latch type
(reset position)
S : Coil polarity of set (operate)
R : Coil polarity of reset (release)
MARKINGS (top view)
1
4
q Part number
w Manufacturer
9 9 0 0
e Country of origin
r Date code
U A 2 – 1 2 N U
t Index mark of relay direction
(pin No. 1, 12)
J A P A N
5
2
3
DATA SHEET ER0450EJ2V0DS00
3
UA2/ UB2 SERIES
PERFORMANCE CHARACTERISTICS (Com m unity)
Contact Form
2 Form c
Maxim um Switching Power
30 W (resistive)
220 Vdc
37.5 VA (resistive)
250 Vac
Maxim um Switching Voltage
Contact Ratings
Maxim um Switching Current
1 A
Maxim um Carrying Current
Minim um Contact Ratings
1 A
10 m V.dc, 10 µA *4
Initial Contact Resistance
100 m Ω Max. (Initial)
Contact Material
Silver alloy with gold alloy overlay
140 to 230 m W
Non-Latch Type
Nom inal Operating Power
Single Coil Latch Type
100 to 120 m W
Operate Tim e (Excluding Bounce)
Release Tim e (Excluding Bounce)
Insulation Resistance
Approxim ately 2 m s
Approxim ately 1 m s without diode
1000 MΩ at 500 Vdc
1
Between Open Contacts
1000 Vac for one m inute (1500 V surge, 10 × 160 µs
)
Breakdown Voltage
Shock Resistance
Between Adjacent Contacts
Between Coil and Contact
1500 Vac for one m inute (2500 V surge, 2 × 10 µs *2)
735 m / s2 (75 G) (m isoperating)
980 m / s2 (100 G) (destructive failure)
10 to 55 Hz at double am plitude of 3 m m (20 G)
(m isoperating)
Vibration Resistance
10 to 55 Hz, double am plitude of 5 m m (30 G)
(Destructive failure)
Am bient Tem perature
Coil Tem perature Rise
–40 to +85˚C
18 degrees at nom inal coil voltage (140 m W)
5 × 107 *3 operations (Non-latch type)
1 × 107 operations (Latch type)
No-load
Load
Running specifications
Weight
30 Vdc 1 A (resistive), 1 × 105 operations at 20˚C
125 Vac 0.3 A (resistive), 1 × 105 operations at 20˚C
Approxim ately 1 gram s
1
2
3
rise tim e : 10 µs, fall tim e : 160 µs
rise tim e : 2 µs, fall tim e : 10 µs
This shows a num ber of operation where it can be running by which a fatal is not caused, and num ber of operation by wich
a stesdy characteristic is m aintained is 1 × 107 tim es.
4
This value is a reference value in the resistive load.
Minim um capacity changes depending on seitching frequency and envirom ent tem perature and the load.
SAFETY STANDARD AND RATING
UL Recognized
(UL508)*
File No E73266
CSA Certificated
(CSA C22.2 No14)✩
File No LR46266
30 Vdc, 1 A
(Resistive)
110 Vdc, 0.3 A (Resistive)
125 Vac, 0.3 A (Resistive)
* Spacing : UL114, UL478
✩ Spacing : CSAstd950
4
DATA SHEET ER0450EJ2V0DS00
UA2/ UB2 SERIES
PART NUMBER SYSTEM
UB2 – 3 S N U – L
Packing code
Nil : Tube (All of UA2, To be select for UB2)
L
R
: Em bossed carrying tape of L type (UB2 only)
: Em bossed carrying tape of R type (UB2 only)
Option
NU : Standard
NJ : Trim m ed lead typr of UA2
NUN : Minim um footprint type of UB2
Lach typr
Nil : Non–latch typr
S
: Single coil latch typr
Nom inal coil voltage
A num erical value of coil voltage (See the following lineup)
Series nam e
UA2 : UA2 Series
UB2 : UB2 Series
NOMINAL LINEUP
Non-latch Type
at 20˚C
Nom inal Coil
Voltage
Coil
Must Operate
Voltage
Must Release
Voltage
Nom inal
Resistance
(Ω) ±10 %
operate power
(m W)
(Vdc)
(Vdc)
(Vdc)
1.5
3
16
64.3
145
1.13
2.25
3.38
3.75
4.5
0.15
0.3
140
140
140
140
140
140
140
230
4.5
5
0.45
0.5
178
6
257
0.6
9
579
6.75
9.0
0.9
12
24
1028
2504
1.2
18.0
2.4
Single-Coil Latch Type
at 20˚C
Nom inal Coil
Voltage
Coil
Must Operate
Voltage
Must Release
Voltage
Nom inal
operate power
(m W)
Resistance
(Ω) ±10 %
(Vdc)
(Vdc)
(Vdc)
1.5
3
22.5
90
1.13
2.25
3.38
3.75
4.5
1.13
2.25
3.38
3.75
4.5
100
100
100
100
100
100
100
120
4.5
5
202.5
250
6
360
9
810
6.75
9.0
6.75
9.0
12
24
1440
4800
18.0
18.0
DATA SHEET ER0450EJ2V0DS00
5
UA2/ UB2 SERIES
Coile Tem perature Rise
30
20
10
0
30
20
10
0
applied power 0.23 W
0.14 W
100
150
200
250
0
5
10
15
20
Applied Power (mW) at 20 degreeC
Energized Time (minute)
Sw itching capacity
Maxim um coil voltage
2.0
1.0
0.5
0.2
0.1
200
150
100
50
DC (resistive)
AC (resistive)
0
–40 –20
0
20
40
60
80
100
10
20
50
100
200
250V. AC
220V. DC
Ambient Temperature (degreeC)
Swiching Voltage (V)
Operate Tim e and Release Tim e (Sam ple : UA2-5NU)
(Without diode)
4
3
2
1
0
4
3
2
1
0
0
100
150
200
250
0
100
150
200
250
Applied Power (mW)
Applied Power (mW)
6
DATA SHEET ER0450EJ2V0DS00
UA2/ UB2 SERIES
Nonload (m echanical) Life Test
(Load: Nonload, Drive: 5VDC 10 Hz 50% duty, at 20 degreeC, Sam ple: UA2-5 n=20)
Operate Voltage
Release Voltage
Make Contact
Breake Contact
5
4
3
2
1
0
200
100
50
20
10
0
Maximum
Average
Minimum
0
0.5
1
5
10
0
0.5
1
5
10
Number of Operations ( × 10 6 Times)
Number of Operations ( × 10 6 Times)
Electrical Life Test
(Load: 5VDC/0.1 A Resistive, Drive: 5VDC 5 Hz 50% duty, at 85 degreeC, Sam ple: UA2-5NU n=10)
Operate Voltage
Release Voltage
Make Contact
Breake Contact
5
4
3
2
1
0
200
100
50
20
10
0
0
0.5
1
0
0.5
1
Number of Operations ( × 10 6 Times)
Number of Operations ( × 10 6 Times)
Breakdow n Voltage
Sam ple : UA2-5NU
(a) Between open contact (sam ple : n=20)
(b) Between adjacent contact (sam ple : n=10)
10
5
10
5
0
0
0.5
1.0
1.5
1.5
2.0
2.5
Breakdown Voltage (kV)
Breakdown Voltage (kV)
(c) Between coil to contact (sam ple : n=10)
10
5
0
1.5
2.0
2.5
2.6
Breakdown Voltage (kV)
DATA SHEET ER0450EJ2V0DS00
7
UA2/ UB2 SERIES
Magnetic Interference
Drift of Operate Voltage
Drift of Operate Voltage
+40
+30
+20
+10
0
+40
+30
+20
+10
0
–10
–20
–30
–40
–10
–20
–30
–40
I
II
III
IV
V
VI
I
II
III
IV
V
VI
Measurment sample
ON OFF
ON
ON
OFF
OFF
ON
OFF
I
II
Layout
III
IV
3 mm
ON
ON
ON
OFF
OFF
OFF
ON : emergized
OFF : no emergized
V
VI
2.5 mm
Mounting space
8
DATA SHEET ER0450EJ2V0DS00
UA2/ UB2 SERIES
TUBE PACKAGE (UA2, UB2)
Dim ension of Package (Unit : mm)
50 pieces / Tube
Material : Polyvinyl chloride
(anti-static treated)
560.0
10.1
Outline of Package
Rubber stopper (Yellow)
Rubber stopper (Green)
Index Mark
TAPE PACKAGE (UB2)
APPEARANCE
TAPE DIMENSION m m (inch)
A
Reel
2.0(0.079)
Top cover tape
0.4
(0.016)
12.0(0.47)
4.0(0.157)
φ
1.5
(0.054)
Embossed carrying tape
φ
2.2
(0.087)
B
A
B
UB2- NU
Max.9.4
(0.370)
8.2
(0.323)
UB2- NUN Max.9.5
(0.370)
6.7
(0.264)
Relay orientation m ark and tape carrying direction.
Orientation mark
Orientation mark
Tape carrying direction
Carrying tape type
Part number
L
R
UB2-
UB2- -L
-R
****
***
DATA SHEET ER0450EJ2V0DS00
9
UA2/ UB2 SERIES
SOLDERING TEMPERATURE CONDITION
Through–hole m ounting type (UA2)
q Autom atic soldering
* Preheating
: 100°C m ax. 1 m inute m ax.
* Solder tem perature : 250°C m ax.
* Solder tim e
: 10 seconds m ax.
w Manual soldering
* Solder tem perature : 350°C m ax.
* Solder tim e
: 3 seconds m ax.
Surface m ounting type (UB2)
IRS Method
T max.; 235
200
175
150
30 sec.
80 sec.
200 sec.
Time
Note:
1. Temperature profile shows printed circuit board surface temperature on the relay terminal portion.
2. Check the actual soldering condition to use other method except above mentioned temperature profiles.
10
DATA SHEET ER0450EJ2V0DS00
UA2/ UB2 SERIES
GUIDE TO APPLICATIONS
1. When connecting coils, refer to the pin configuration to prevent m isoperation or m alfunction.
2. The latch type relay should be initialized at the appointed position (set or reset position) when using, and should
be energized or deenergized to the specified polarity to avoid wrong operations by reversed contact state.
3. Ultrasonic cleaning is not recom m ended to keep contact perform ance reliable. Alcohol based solvents are
available as proper solvents.
4. Pressurized stress on the relay cover m ay affect reliable operation.
5. Minim um contact load of the relay is 10 m Vdc, 10 µA.
This value is a reference value in the resistance load.
Minim um capacity changes depending on switching frequency and environm ent tem perature and the load.
DATA SHEET ER0450EJ2V0DS00
11
UA2/ UB2 SERIES
No part of this docum ent m ay be copied or reproduced in any form or by any m eans without the prior
written consent of NEC Corporation. NEC Corporation assum es no responsibility for any errors which
m ay appear in this docum ent.
NEC Corporation does not assum e any liability for infringem ent of patents, copyrights or other intellec-
tual property rights of third parties by or arising from use of a device described herein or any other
liability arising from use of such device. No license, either express, im plied or otherwise, is granted
under any patents, copyrights or other intellectual property rights of NEC Corporation or others.
While NEC Corporation has been m aking continuous effort to enhance the reliability of its electronic
com ponents, the possibility of defects cannot be elim inated entirely. To m inim ize risks of dam age or
injury to persons or property arising from a defect in an NEC electronic com ponent, custom ers m ust
incorporate sufficient safety m easures in its design, such as redundancy, fire-containm ent, and anti-
failure features.
NEC devices are classified into the following three quality grades:
"Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based
on a custom er designated "quality assurance program " for a specific application. The recom m ended
applications of a device depend on its quality grade, as indicated below. Custom ers m ust check the
quality grade of each device before using it in a particular application.
Standard: Computers, office equipment, communications equipment, test and measurement equipment, au-
dio and visual equipment, home electronic appliances, machine tools, personal electronic equip-
ment and industrial robots
Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster
system s, anti-crim e system s, safety equipm ent and m edical equipm ent (not specifically de-
signed for life support)
Specific: Aircrafts, aerospace equipm ent, subm ersible repeaters, nuclear reactor control system s, life
support systems or medical equipment for life support, etc.
The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books.
If customers intend to use NEC devices for applications other than those specified for Standard quality grade,
they should contact an NEC sales representative in advance.
Anti-radioactive design is not implemented in this product.
相关型号: