DATA SHEET
MOS INTEGRATED CIRCUIT
µPD72850A
IEEE1394 400Mbps PHY
The µPD72850A is the 3-port physical layer LSI which complies with the P1394a draft 2.0 specifications.
The µPD72850A works up to 400 Mbps. It is an upgrade of NEC's µPD72850.
FEATURES
•
•
•
The Three-port Physical Layer LSI complies to IEEE P1394a draft 2.0
Connection debounce
Arbitration enhancements
• Arbitrated short bus reset
• Ack-accelerated arbitration
• Fly-by concatenation
• Multiple-speed packet concatenation
• Arbitration enhancements and cycle start (controlled by the Link layer)
Performance optimization via PHY pinging
Priority arbitration (controlled by the Link layer)
Data rate: 393.216 / 196.608 / 98.304 Mbps
Compliant with Suspend/Resume function as defined in P1394a draft 2.1
3.3 V single power supply
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Electrical isolated Link interface
24.576 MHz crystal clock generation, 393.216 MHz PLL multiplying frequency
System power management by signaling of node power class information
Cable power monitor (CPS) is equipped
Fully interoperable with IEEE1394 std 1394 Link (FireWireTM, i.LINKTM
)
Cable bias and terminal voltage driver supply function (for 3-port each)
Separate digital power and analog GND
Enable/Disable port control switch when power supply is powered on
Support Suspend/Resume Off mode (Compliant with P1394a draft 1.3)
Number of supported port are selectable
• 1port, 2port, 3port. This selection is only under Suspend/Resume Off mode
Compliant with MD8405E (FUJIFILM MICRODEVICES CO., LTD)
•
ORDERING INFORMATION
Part number
Package
µPD72850AGK-9EU
80-pin plastic TQFP (Fine pitch) (12 x 12 mm)
The information in this document is subject to change without notice. Before using this document, please
confirm that this is the latest version.
Not all devices/types available in every country. Please check with local NEC representative for
availability and additional information.
Document No. S14452EJ1V0DS00 (1st edition)
Date Published October 1999 NS CP(K)
Printed in Japan
1999
µPD72850A
BLOCK DIAGRAM
TpA0p
TpA0n
CMC
PC0
PC1
PC2
PORTDIS
PSEL
SUS/RES
Cable
Port1
TpB0p
TpB0n
LREQ
Arbitration
and Control
State Machine
Logic
LPS
DIRECT
SCLK
LKON
CTL0
CTL1
D0
TpA1p
TpA1n
Cable
Port2
TpB1p
TpB1n
Link
Interface
I/O
D1
D2
D3
D4
D5
D6
TpA2p
TpA2n
Cable
Port3
TpB2p
TpB2n
D7
TpBias0
TpBias1
TpBias2
R0
Voltage
and
Current
Generator
Receive Data
Decoder and
Retimer
R1
Crystal
Oscillator
PLL
XI
XO
FIL0
FIL1
Transmit Data
Encoder
RESETB
CPS
System
and
Cable
Power
Status
Transmit
Clock
Generator
2
Data Sheet S14452EJ1V0DS00
µPD72850A
PIN CONFIGURATION (Top View)
80-pin plastic TQFP (Fine pitch) (12 x 12 mm)
•
PC1
PC0
TpA0p
TpA0n
TpB0p
TpB0n
TpA1p
TpA1n
TpB1p
TpB1n
TpA2p
TpA2n
TpB2p
TpB2n
TpBias0
TpBias1
TpBias2
AV
1
2
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
CMC
DGND
LPS
3
4
5
LREQ
6
DD
DV
7
DGND
SCLK
8
9
DD
DV
10
11
12
13
14
15
16
17
18
19
20
DGND
CTL0
CTL1
DD
DV
D0
D1
DD
DGND
D2
AGND
CPS
D3
RI1
DGND
RI0
3
Data Sheet S14452EJ1V0DS00
µPD72850A
PIN NAME
AGND
AVDD
: Analog GND
: Analog Power
CMC
: Configuration Manager Capable
: Cable Power Status
CPS
CTL0
: Link Interface Control (bit 0)
CTL1
: Link Interface Control (bit 1)
D0-D7
DGND
Direct
DVDD
: Data Input/Output
: Digital GND
: PHY/Link Isolation Barrier Control Input
: Digital VDD
FIL0
: APLL Filter Ground
FIL1
: APLL Filter
IC(H)
: Internally Connected (High Clamped)
: Link-on Signal Output
LKON
LPS
: Link Power Status Input
LREQ
PC0-PC2
PORTDIS
PSEL
RESETB
RI0
: Link Request Input
: Power Class Set Input
: Port Disable
: Support Number of Port Select
: Power on Reset Input
: Reference Power Set, Connect Resistor 0
: Reference Power Set, Connect Resistor 1
: Link Control Output Clock
RI1
SCLK
SUS/RES
TpA0n
TpA0p
TpA1n
TpA1p
TpA2n
TpA2p
TpB0n
TpB0p
TpB1n
TpB1p
TpB2n
TpB2p
TpBias0
TpBias1
TpBias2
XI
: Suspend/Resume Function Select
: First Port Twisted Pair Cable A Negative Phase I/O
: First Port Twisted Pair Cable A Positive Phase I/O
: Second Port Twisted Pair Cable A Negative Phase I/O
: Second Port Twisted Pair Cable A Positive Phase I/O
: Third Port Twisted Pair Cable A Negative Phase I/O
: Third Port Twisted Pair Cable A Positive Phase I/O
: First Port Twisted Pair Cable B Negative Phase I/O
: First Port Twisted Pair Cable B Positive Phase I/O
: Second Port Twisted Pair Cable B Negative Phase I/O
: Second Port Twisted Pair Cable B Positive Phase I/O
: Third Port Twisted Pair Cable B Negative Phase I/O
: Third Port Twisted Pair Cable B Positive Phase I/O
: First port Twisted Pair Output
: Second Port Twisted Pair Output
: Third Port Twisted Pair Output
: Crystal Oscillator Connection XI
: Crystal Oscillator Connection XO
XO
4
Data Sheet S14452EJ1V0DS00
µPD72850A
CONTENTS
1. PIN FUNCTIONS .....................................................................................................................................7
1.1 Cable Interface Pins.........................................................................................................................7
1.2 Link Interface Pins...........................................................................................................................8
1.3 Control Pins......................................................................................................................................8
1.4 IC........................................................................................................................................................9
1.5 Power Supply Pins...........................................................................................................................9
1.6 Other Pins.........................................................................................................................................9
2. PHY REGISTERS...................................................................................................................................10
2.1 Complete Structure for PHY Registers........................................................................................10
2.2 Port Status Page (Page 000) .........................................................................................................13
2.3 Vendor ID Page (Page 001) ...........................................................................................................14
3. INTERNAL FUNCTION ..........................................................................................................................15
3.1 Link Interface..................................................................................................................................15
3.1.1 Connection Method............................................................................................................................... 15
3.1.2 LPS (Link Power Status)....................................................................................................................... 15
3.1.3 LREQ, CTL0,CTL1, and D0-D7 Pins .................................................................................................... 15
3.1.4 SCLK..................................................................................................................................................... 15
3.1.5 LKON .................................................................................................................................................... 16
3.1.6 Direct .................................................................................................................................................... 16
3.1.7 Isolation Barrier..................................................................................................................................... 16
3.2 Cable Interface ...............................................................................................................................18
3.2.1 Connections.......................................................................................................................................... 18
3.2.2 Cable Interface Circuit .......................................................................................................................... 19
3.2.3 Unused Ports ........................................................................................................................................ 19
3.2.4 CPS....................................................................................................................................................... 19
3.3 Suspend/Resume...........................................................................................................................19
3.3.1 Suspend/Resume On Mode (SUS/RES = “H”)...................................................................................... 19
3.3.2 Suspend/Resume Off Mode (SUS/RES = “L”)...................................................................................... 19
3.4 PLL and Crystal Oscillation Circuit..............................................................................................20
3.4.1 Crystal Oscillation Circuit...................................................................................................................... 20
3.4.2 PLL ....................................................................................................................................................... 20
3.5 PC0-PC2, CMC................................................................................................................................20
3.6 RESETB...........................................................................................................................................20
3.7 RI1, RI0............................................................................................................................................20
4. PHY/LINK INTERFACE..........................................................................................................................21
4.1 Initialization of Link Power Status (LPS) and PHY/Link Interface.............................................21
4.2 Link-on Indication..........................................................................................................................22
4.3 PHY/Link Interface Operation (CTL0, CTL1, LREQ, D0-D7) .......................................................23
4.3.1 CTL0,CTL1 ........................................................................................................................................... 23
4.3.2 LREQ .................................................................................................................................................... 23
4.3.3 PHY/Link Interface Timing .................................................................................................................... 27
4.4 Acceleration Control......................................................................................................................28
4.5 Transmit Status..............................................................................................................................29
5
Data Sheet S14452EJ1V0DS00
µPD72850A
4.6 Transmit..........................................................................................................................................30
4.7 Cancel .............................................................................................................................................31
4.8 Receive............................................................................................................................................32
5. CABLE PHY PACKET............................................................................................................................33
5.1 Self_ID Packet ................................................................................................................................33
5.2 Link-on Packet ...............................................................................................................................34
5.3 PHY Configuration Packet ............................................................................................................34
5.4 Extended PHY Packet....................................................................................................................34
5.4.1 Ping Packet........................................................................................................................................... 35
5.4.2 Remote Access Packet......................................................................................................................... 35
5.4.3 Remote Reply Packet ........................................................................................................................... 36
5.4.4 Remote Command Packet.................................................................................................................... 36
5.4.5 Remote Confirmation Packet................................................................................................................ 37
5.4.6 Resume Packet..................................................................................................................................... 37
6. ELECTRICAL SPECIFICATIONS..........................................................................................................38
7. APPLICATION CIRCUIT EXAMPLE......................................................................................................43
7.1 IEEE1394 Interface.........................................................................................................................43
7.2 NEC/FFM Board Sharing ...............................................................................................................44
8. PACKAGE DRAWING............................................................................................................................45
9. RECOMMENDED SOLDERING CONDITIONS...................................................................................46
6
Data Sheet S14452EJ1V0DS00
µPD72850A
1. PIN FUNCTIONS
1.1 Cable Interface Pins
Name
TpA0p
Pin No.
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I
Function
60
59
58
57
56
55
54
53
52
51
50
49
64
First port twisted pair cable A positive phase I/O
First port twisted pair cable A negative phase I/O
First port twisted pair cable B positive phase I/O
First port twisted pair cable B negative phase I/O
Second port twisted pair cable A positive phase I/O
Second port twisted pair cable A negative phase I/O
Second port twisted pair cable B positive phase I/O
Second port twisted pair cable B negative phase I/O
Third port twisted pair cable A positive phase I/O
Third port twisted pair cable A negative phase I/O
Third port twisted pair cable B positive phase I/O
Third port twisted pair cable B negative phase I/O
Port disable.
TpA0n
TpB0p
TpB0n
TpA1p
TpA1n
TpB1p
TpB1n
TpA2p
TpA2n
TpB2p
TpB2n
PORTDIS
SUS/RES(71pin)=“1”
This selected state will be loaded to Disabled bit which allocated PHY register
Port Status Page when power-on reset.
The PORTDIS pin is ignored except power-on reset.
1: All 3 ports will be disabled.
0: All 3 ports will be enabled.
SUS/RES(71pin)=“0”
Combination with PSEL(66pin) input the supported number of port will be
selected.
Please refer to PSEL.
PSEL
66
I
Supported number of Port select (This function will be activated only under
SUS/RES=“0”).
64pin
66pin
1Port(Port0)
0
1
0
1
0
0
2Port(Port0,1)
3Port(Port0-2)
When SUS/RES=“1”, this pin should be connected to AGND.
Suspend/Resume function select
SUS/RES
CPS
71
43
I
I
1: Suspend/Resume on (P1394a draft 2.1 compliant)
0: Suspend/Resume off (P1394a draft 1.3 compliant)
Power cable status.
Connect to the cable through a 390 kΩ resistor.
0: Cable power fail
1: Cable power on
7
Data Sheet S14452EJ1V0DS00
µPD72850A
1.2 Link Interface Pins
Name
Pin No.
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I
Function
D0
D1
D2
D3
D4
D5
D6
D7
15
16
18
19
21
22
24
25
12
13
6
Data input/output (bit 0)
Data input/output (bit 1)
Data input/output (bit 2)
Data input/output (bit 3)
Data input/output (bit 4)
Data input/output (bit 5)
Data input/output (bit 6)
Data input/output (bit 7)
Link interface control (bit 0)
Llink interface control (bit 1)
Link request input
CTL0
CTL1
LREQ
SCLK
9
O
Link control output clock
LPS 1: 49.152 MHz output
LPS 0: Clamp to 0 (The clock signal will be output within 25 µsec after change
to “0”)
LPS
5
I
Link power status input
0: Link power off
1: Link power on (PHY/Link direct connection)
Clock signal of about 300 kHz (if isolation)
Link-on signal output pin
LKON
Direct
78
77
O
I
Link-on signal is 6.144 MHz clock output.
Please refer to 4.2 Link-on Indication.
PHY/Link isolation barrier control input
0: Isolation barrier
1: PHY/Link direct connection
1.3 Control Pins
Name
PC0
Pin No.
I/O
Function
2
I
I
I
I
Power class set input
This pin status will be loaded to Pwr_class bit which allocated to PHY register 4H.
IEEE1394-1995 chapter [4.3.4.1]
PC1
PC2
CMC
1
79
3
Configuration manager capable setting.
This pin status will be loaded to Contender bit which allocated to PHY register 4H.
0: Non contender
1: Contender
RESETB
30
I
Power on reset input.
Connect to DGND through a 0.1 µF capacitor.
0: Reset
1: Normal
8
Data Sheet S14452EJ1V0DS00
µPD72850A
1.4 IC
Name
Pin No.
75, 76
I/O
I
Function
Internally Connected (High Clamped)
IC
1.5 Power Supply Pins
Name
AVDD
Pin No.
31, 36
I/O
Function
-
-
-
-
-
-
-
-
-
Analog power 1 (APLL, OSC)
Analog power 2 (Bias)
Analog power 3 (Cable Interface)
Analog GND1 (PLL, OSC)
Analog GND2 (Bias)
40, 45
63, 67, 73
32, 33
AGND
39, 44
61
Analog GND3 (Common)
Analog GND4 (Speed signal)
Analog GND5 (Port)
62
65, 68-70, 72
7, 10, 14,
26-28, 80
4, 8, 11, 17,
20, 23, 29, 74
DVDD
Digital VDD
DGND
-
Digital GND
1.6 Other Pins
Name
Pin No.
I/O
O
O
O
-
Function
TpBias0
TpBias1
TpBias2
RI0
48
47
46
41
First port twisted pair output
Second port twisted pair output
Third port twisted pair output
Resistor connection pin0 for reference current generator.
Please connect to RI1 pin via 9.1 kΩ resistor.
Resistor connection pin1 for reference current generator.
Please connect to RI0 pin via 9.1 kΩ resistor.
APLL filter (No need to assemble)
RI1
42
-
FIL1
FIL0
XI
34
35
37
38
-
-
-
-
APLL filter ground (No need to assemble)
Crystal oscillator connection XI
XO
Crystal oscillator connection XO
9
Data Sheet S14452EJ1V0DS00
µPD72850A
2. PHY REGISTERS
2.1 Complete Structure for PHY Registers
Figure 2-1. Complete Structure of PHY Registers
0
1
2
3
4
5
6
7
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Physical_ID
R
PS
RHB
IBR
Gap_count
Extended (7)
Max_speed
Contender
ISBR
Reserved
Reserved
Jitter
Total_ports
Delay
Link_active
Resume_int
Pwr_class
Loop
Pwr_fail
Timeout
Port_event Enab_accel Enab_multi
Reserved
Reserved
Page_select
Port_select
Register0 (page_select)
Register1 (page_select)
Register2 (page_select)
Register3 (page_select)
Register4 (page_select)
Register5 (page_select)
Register6 (page_select)
Register7 (page_select)
10
Data Sheet S14452EJ1V0DS00
µPD72850A
Table 2-1. Bit Field Description (1/2)
Reset value Description
Field
Physical_ID
R
Size
6
R/W
R
000000
0
Physical_ID value selected from Self_ID period.
If this bit is 1, the node is root.
1: Root
1
R
0: Not root
PS
1
R
Cable power status.
1: Cable power on
0: Cable power off
RHB
IBR
1
1
R/W
R/W
0
0
Root Hold -off bit. If 1, becomes root at the bus reset.
Initiate bus reset.
Setting to 1 begins a long bus reset.
Long bus reset signal duration: 166 µsec.
Returns to 0 at the beginning of bus reset.
Gap count value.
Gap_count
6
R/W
111111
It is updated by the changes of transmitting and receiving the PHY
configuration packet Tx/Rx.
The value is maintained after first bus reset.
After the second bus reset it returns to reset value.
Shows the extended register map.
Supported port number.
Extended
3
4
R
R
111
Total_ports
0011
When SUS/RES(71pin)=“1”
0011 : 3 ports
When SUS/RES(71pin)=“0”
Combination with PSEL(66pin) input the supported number of port will be
selected. Please refer to 1.1 Cable Interface Pins.
0001 : 1 port
0010 : 2 port
0011 : 3 port
Max_speed
3
R
010
Indicate the maximum speed that this node supports.
010: 98.304, 196.608 and 393.216 Mbps
Indicate worst case repeating delay time. 144+(2 x 20)=184 nsec
Link active.
Delay
4
1
R
0010
1
Link_active
R/W
1 : Enable
0 : Disable
The logical AND status of this bit and LPS pin.
State will be referred to “L bit” of Self-ID Packet#0.
Contender.
Contender
1
R/W
See
Description
“1” indicate this node support bus manager function. This bit will be referred
to “C bit” of Self-ID Packet#0.
The reset data is depending on CMC pin setting.
CMC pin condition
1: Pull up (Contender)
0: Pull down (Non Contender)
Jitter
3
R
010
The difference of repeating time (Max.-Min.). (2+1) x 20=60 nsec
11
Data Sheet S14452EJ1V0DS00
µPD72850A
Table 2-1. Bit Field Description (2/2)
Reset value Description
Field
Size
3
R/W
R/W
Pwr_class
See
Power class.
Description
Please refer to IEEE1394 -1995 [4.3.4.1].
This bit will be referred to Pwr field of Self-ID Packet#0.
The reset data will be determined by PC0-PC2 Pin status.
Resume interrupt enable. When set to 1, if any one port does resume, the
Port_event bit becomes 1.
Resume_int
ISBR
1
1
R/W
R/W
0
0
Initiate short (arbitrated) bus reset.
Setting to 1 acquires the bus and begins short bus reset.
Short bus reset signal output : 1.3 µsec
Returns to 0 at the beginning of the bus reset.
Loop detection output.
Loop
1
1
R/W
R/W
0
0
1: Detection
Writing 1 to this bit clears it to 0.
Writing 0 has no effect.
Pwr_fail
Power cable disconnect detect.
It becomes 1 when there is a change from 1 to 0 in the CPS bit.
Writing 1 to this bit clears it to 0.
Writing 0 has no effect.
Timeout
1
1
R/W
R/W
0
0
Arbitration state machine time-out.
Writing 1 to this bit clears it to 0.
Writing 0 has no effect.
Port_event
Set to 1 when the Int_Enable bit in the register map of each port is 1 and
there is a change in the ports connected, Bias, Disabled and Fault bits.
Set to 1 when the Resume_int bit is 1 and any one port does resume.
Writing 1 to this bit clears it to 0.
Writing 0 has no effect.
Enab_accel
1
R/W
0
Enables arbitration acceleration.
Ack-acceleration and Fly-by arbitration are enabled.
1: Enabled
0: Disabled
If this bit changes while the bus request is pending, the operation is not
guaranteed.
Enab_multi
Page_select
Port_select
1
3
4
R/W
R/W
R/W
0
Enable multi-speed packet concatenation.
Setting this bit to 1 follows multi-speed transmission.
When this bit is set to 0,the packet will be transmitted with the same speed
as the first packet.
000
0000
Select page address between 1000 to 1111.
000: Port Status Page
001: Vendor Definition Page
Others: Unused
Port Selection.
Selecting 000 (Port Status Page) with the page selection selects the port.
0000: Port 0
0001: Port 1
0010: Port 2
Others: Unused
Reserved
-
R
000…
Reserved. Read as 0.
12
Data Sheet S14452EJ1V0DS00
µPD72850A
2.2 Port Status Page (Page 000)
Figure 2-2. Port Status Page
0
1
2
3
4
5
6
7
1000
1001
1010
1011
1100
1101
1110
1111
AStat
Negotiated_speed
BStat
Int_enable
Reserved
Child
Connected
Bias
Disabled
Fault
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Table 2-2. Bit Field Description
Field
Size
2
R/W
R
Reset value
Description
AStat
XX
A port status value.
00:---, 10: “0”
01: “1”, 11: “Z”
BStat
Child
2
1
1
1
R
R
R
R
XX
B port status value.
00:---, 10: “0”
01: “1”, 11: “Z”
Child node status value.
1: Connected to child node
0: Connected to parent node
Connection status value.
1: Connected
Connected
Bias
0
0: Disconnected
Bias voltage status value.
1: Bias voltage
0: No bias voltage
Disabled
1
3
R/W
R
See
The reset value is set by the PORTDIS pin.
1: Disable
Description
Negotiated_
Speed
Shows the maximum data transfer rate of the node connected to this port.
000: 100 Mbps
001: 200 Mbps
010: 400 Mbps
Int_enable
Fault
1
1
R/W
R/W
0
0
The Port_event is set to 1 by a change to 1 of the Connected, Bias, Disable,
and Fault bits.
Set to 1 if an error occurs during Suspend/Resume.
Writing 1 to this bit clears it to 0.
Writing 0 has no effect.
Reserved
-
R
000…
Reserved. Read as 0.
13
Data Sheet S14452EJ1V0DS00
µPD72850A
2.3 Vendor ID Page (Page 001)
Figure 2-3. Vendor ID Page
0
1
2
3
4
5
6
7
1000
1001
1010
1011
1100
1101
1110
1111
Compliance_level
Reserved
Vendor_ID
Product_ID
Table 2-3. Bit Field Description
Reset value
Field
Size
8
R/W
R
Description
Compliance_level
Vendor_ID
00000001
00004CH
According to IEEE P1394a.
24
24
-
R
Company ID Code value, NEC IEEE OUI.
Product code.
Product_ID
Reserved
R
R
000…
Reserved. Read as 0.
14
Data Sheet S14452EJ1V0DS00
µPD72850A
3. INTERNAL FUNCTION
3.1 Link Interface
3.1.1 Connection Method
Figure 3-1. PHY/Link Connection Method
D0-D7
CTL0,CTL1
LREQ
SCLK
LPS
PHY
Link
µ
PD72850A
LKON
Note
DIRECT
DD
Note Clamping to V
provides direct connection to Link.
Clamping to GND connects through isolation barrier to Link.
The isolation barrier connection circuit is described in 3.1.7 Isolation Barrier.
3.1.2 LPS (Link Power Status)
LPS is a function to monitor the On/Off status of the Link power supply. After 1.2 µsec or more, LPS is Low, the
PHY/Link is reset and D and CTL are output Low (when the isolation barrier is Hi-Z). After 2.5 µsec or more, LPS is
Low, moreover, the PHY stops the supply of SCLK and SCLK outputs Low (when the isolation barrier is Hi-Z).
3.1.3 LREQ, CTL0,CTL1, and D0-D7 Pins
LREQ
: Indicates that a request is received from Link.
CTL0,CTL1 : Bi-directional pin which controls the functions between the PHY/Link interface.
D0-D7
: Bi-directional pin which controls the data Transfer/Receive status signal, and the speed code
Transfer/Receive status signal.
3.1.4 SCLK
49.152 MHz clock supplied by PHY for the PHY/Link interface synchronization.
15
Data Sheet S14452EJ1V0DS00
µPD72850A
3.1.5 LKON
When the Link power is off, it outputs a clock of 6.144 MHz. LKON outputs under the following conditions: LPS is
Low and the internal PHY register of the Link_active bit is 0.
• Link-on packet is received.
• Any bit of Loop, Pwr_fail, Timeout or Port_event is the PHY internal register becomes 1, and moreover either
LPS or Link_active bit is 0.
When LPS is asserted, LKON returns to Low.
3.1.6 Direct
Set Direct to Low for using the isolation barrier.
3.1.7 Isolation Barrier
The IEEE1394 cable holds signals for Data/Strobe in addition to power and ground.
When the ground potential is different between connecting devices, the DC and AC current flows through the
ground line in the cable and there is a possibility of malfunction due to ground difference between the two PHY.
The µPD72850A uses the isolation barrier to couple the AC between the PHY/Link interface to overcome the
ground difference problem. Connecting the Direct pin to Low enables the digital differential circuit of the µPD72850A.
The differential circuit propagates only the change in the signal; the interface will be driven only during transitions
High → Low or Low → High. The interface will assume the high impedance state when there is no signal change.
The µPD72850A uses Schmitt trigger input buffers for D, CTL, LREQ and LPS pins to prevent noise when the bus
assumes a high impedance state.
The digital differential circuit and the Schmitt trigger input buffers are needed on the Link layer controller LSI to
implement the isolation barrier.
Figure 3-2. Waveforms of the Isolation Barrier
Isolation Barrier not used
0
0
1
1
1
Z
0
0
0
Z
0
Z
1
1
0
0
0
Z
Using Isolation Barrier
(Digital differential circuit)
16
Data Sheet S14452EJ1V0DS00
µPD72850A
Figure 3-3. Isolation Barrier Circuits
(a) CTL0,CTL1, D0-Dn Isolation Barrier Circuit
Required when LinkVDD is 5 V
LinkVDD
DVDD
Link
µ
PD72850A
Ω
Ω
5 k
5 k
Ω
100
µ
F
µ
F
0.001
0.001
Ω
Ω
5 k
5 k
Ω
300
LinkGND
LinkGND
DGND
(b) Link-on Isolation Barrier Circuit
LinkVDD
Link
µ
PD72850A
Ω
5 k
Ω
100
µ
F
0.001
Ω
1.6 k
LinkGND
(c) LPS Isolation Barrier Circuit
DVDD
Link
µ
PD72850A
Ω
8.4 k
Ω
10 k
µ
F
0.033
Ω
1.6 k
DGND
(d) LREQ Isolation Barrier Circuit
Required when LinkVDD is 5 V
DVDD
LinkVDD
5k
Link
µ
PD72850A
Ω
Ω
5 k
Ω
100
µ
F
µ
F
0.001
0.001
Ω
5 k
Ω
5 k
Ω
300
LinkGND
LinkGND
DGND
(e) SCLK Isolation Barrier Circuit
LinkVDD
5 k
DVDD
Link
µ
PD72850A
Ω
Ω
5 k
µ
F
0.001
Ω
Ω
5 k
5 k
LinkGND
DGND
17
Data Sheet S14452EJ1V0DS00
µPD72850A
3.2 Cable Interface
3.2.1 Connections
Figure 3-4. Cable Interface
Connection Detection Current
Connection Detection Comparator
Common Mode Speed Current driver
TpBias
TpAp
+
-
TpBp
Driver
Driver
Ω
Ω
Ω
Ω
Ω
Ω
7 k
7 k
56
56
7 k
7 k
Ω
Ω
56
56
TpAn
TpBn
Receiver
+
Receiver
+
µ
µ
Ω
5.1 k
1
F
0.01
F
270 pF
-
-
Arbitration Comparators
Arbitration Comparators
+
-
+
-
+
-
+
-
Common Mode Comparators
Common Mode Comparator
+
+
-
-
+
-
Connection Detection Current
Connection Detection Comparator
Common Mode Speed Current Driver
TpBias
TpAp
+
-
TpBp
Driver
Driver
Ω
Ω
Ω
Ω
7 k
7 k
56
56
Ω
Ω
56
56
Ω
7 k
TpBn
Ω
7 k
TpAn
Receiver
Receiver
+
+
-
µ
F
µ
1
0.01
F
270 pF
Ω
5.1 k
-
Arbitration Comparators
Arbitration Comparators
+
-
+
-
+
-
+
-
Common Mode Comparator
Common Mode Comparators
+
+
-
-
+
-
18
Data Sheet S14452EJ1V0DS00
µPD72850A
3.2.2 Cable Interface Circuit
Each port is configured with two twisted-pairs of TpA and TpB.
TpA and TpB are used to monitor the state of the Transmit/Receive line, control signals, data and cables.
During transmission to the IEEE1394 bus, the Data/Strobe signal received from the Link layer controller is
encoded, converted from parallel to serial and transmitted.
While receiving from the IEEE1394 bus, the Data/Strobe signal from TpA, TpB is converted from serial to parallel
after synchronization by SCLK, then transmitted to the Link layer controller in 2/4/8 bits according to the data rate of
100/200/400 Mbps.
The bus arbitration for TpA and TpB and the state of the line are monitored by the built-in comparator. The state of
the IEEE1394 bus is transmitted to the state machine in the LSI.
3.2.3 Unused Ports
TpAp, TpAn : Not connected
TpBp, TpBn : AGND
TpBias
: Connected to AGND using a 1.0 µF load capacitor
3.2.4 CPS
An external resistance of 390 kΩ is connected in series to the power cable to monitor the power of the power
cable. If the cable power falls under 7.5 V there is an indication to the Link layer controller that the power has failed.
3.3 Suspend/Resume
3.3.1 Suspend/Resume On Mode (SUS/RES = “H”)
There are two ways of transition from the active status to the suspended status.
One is when the receipt of a remote command packet that sets the initiate suspend command. After that, the PHY
transmits a remote confirmation packet with the ok bit set, subsequently signals TX_SUSPEND to the connected
peer PHY with the port which specified by the port field in the remote command packet, and then the PHY port
transitions to the suspended state.
The other is when the receipt of a RX_SUSPEND or RX_DISABLE_NOTIFY signal. When the port observes
RX_SUSPEND, it transmits TX_SUSPEND to the active ports.
The TX_SUSPEND transmitted propagates until it reaches a leaf node. The PHY port transitions to the suspended
state. The propagation of the suspended domain may be blocked by a PHY compliant with IEEE Std 1394-1995, a
disabled or a suspended port.
Any one of a number of reasons may cause a suspended port to attempt to resume normal operations:
• Bias is detected and there is no fault condition;
• A resume packet is received or transmitted by the PHY;
• A remote command packet that sets the resume port command is received; or
• Either port of a node without active ports detects bias.
3.3.2 Suspend/Resume Off Mode (SUS/RES = “L”)
• Remote command packet is ignored.
• Resume packet is ignored.
• Disabled, Int_enable and resume_int bits in PHY register are ignored.
• Responses to Remote access packet.
• Detects the connection of the port in TpBias.
19
Data Sheet S14452EJ1V0DS00
µPD72850A
3.4 PLL and Crystal Oscillation Circuit
3.4.1 Crystal Oscillation Circuit
To supply the clock of 24.576 MHz ± 100 ppm, use an external capacitor of 10 pF and a crystal of 50 ppm.
3.4.2 PLL
The crystal oscillator multiplies the 24.576 MHz frequency by 16 (393.216 MHz).
3.5 PC0-PC2, CMC
CMC shows the bus manager function which corresponds to the c bit of the Self_ID packet and the Contender bit
in the PHY register when the input is High.
The value of CMC can be changed with software through the Link layer; this pin sets the initial value during Power-
on Reset. Use a pull-up or pull-down resistor of 10 kΩ, based on the device’s specification.
The PC0-PC2 pin corresponds to the power field of the Self_ID packet and Pwr_class in the PHY register. Refer to
Section 4.3.4.1 of the IEEE1394-1995 specification for information regarding the Pwr_class. The value of Pwr can be
changed with software through the Link layer controller; this pin sets the initial value during Power-on Reset. Use a
pull-up or pull-down resistor of 10 kΩ based on the application.
3.6 RESETB
Connect an external capacitor of 0.1 µF between the pins RESETB and GND. If the voltage drops below 0 V, a
reset pulse is generated. All of the circuits are initialized, including the contents of the PHY register.
3.7 RI1, RI0
Connect an external resistor of 9.1 kΩ to limit the LSI’s current.
20
Data Sheet S14452EJ1V0DS00
µPD72850A
4. PHY/LINK INTERFACE
4.1 Initialization of Link Power Status (LPS) and PHY/Link Interface
The LPS pin monitors the On/Off status of the Link power state. This pin is used during the PHY/Link interface
Enable/Disable (initialization).
Reset
When the LPS input pin is Low for TLPS_RESET:
• CTL0,CTL1 and D0-D7 output Low (When the isolation barrier is Hi-Z).
• SCLK continuously supplies the clock signal to the Link.
Disable
When the LPS input pin is Low for TLPS_DISABLE:
•
CTL0,CTL1, D0-D7 continue to output Low as TLPS_RESET has already occurred (When the isolation barrier is Hi-Z).
• SCLK to Link stops and it outputs Low (When the isolation barrier is Hi-Z).
Table 4-1. LPS Timing Parameters
Parameter
LPS = Low propagation delay (with isolation barrier)
LPS = High propagation delay (with isolation barrier)
Reset active
Symbol
MIN.
0.09
0.09
1.2
MAX.
1.00
1.00
2.75
30
Unit
µs
tLPSL
tLPSH
µs
tLPS_RESET
tLPS_DISABLE
tRESTORE
µs
Disable active
25
µs
Setup time when using isolation barrier
15
20
µs
Figure 4-1. LPS Waveform when Connected to Isolation Barrier
tLPSH
tLPSL
21
Data Sheet S14452EJ1V0DS00
µPD72850A
Figure 4-2. PHY/Link Interface Reset and Disable
(a) Reset
D, CTL, LREQ
LPS
LPS
(with isolation barrier)
SCLK
tLPS_RESET
tRESTORE
(b) Disable
D, CTL, LREQ
LPS
LPS
(with isolation barrier)
SCLK
tRESTORE
tLPS_DISABLE
4.2 Link-on Indication
When the power supply of Link is off (LPS is Low and the internal PHY register Link_active bit is 0), the pin LKON
outputs High according to the following conditions: (With isolation barrier, it outputs a clock of 6.144 MHz)
• Link-on packet is received.
• When any bit of the µPD72850A PHY register’s loop, Pwr fail, Timeout or Port_event becomes 1, and either LPS
or the Link_active bit is 0.
Table 4-2. Link-on Timing
Parameter
MIN.
4
MAX.
8
Unit
MHz
%
Frequency
Duty Cycle
40
60
Propagation delay before the Link becomes active (LPS is
asserted and the Link_active bit in the PHY register is 1).
500
ns
• If LPS or the Link_active bit is 0, the Link is considered inactive.
When the Link is inactive and any of Loop, PWR_fail, Timeout, Port_event becomes 1, then Link-on is asserted
High.
• When the Link is active (both LPS and Link_active become 1) and Loop, Pwr_fail, Timeout and Port_event
become 1, Status transfer is sent on the PHY/Link interface.
22
Data Sheet S14452EJ1V0DS00
µPD72850A
• The µPD72850A activates the PHY/Link interface when LPS is 1, regardless of the value of the Link active bit.
4.3 PHY/Link Interface Operation (CTL0, CTL1, LREQ, D0-D7)
The PHY/Link Interface consists of the following operations:
• Status transfer to the Link layer controller by CTL
• Transmit packet
• Receive packet
• Request from the Link layer controller by LREQ
4.3.1 CTL0,CTL1
CTL0,CTL1 controls the PHY/Link interface as shown in the Table 4-3.
Table 4-3. CTL Controls PHY
CTL0,CTL1
Type
Content
00
01
10
11
Idle
PHY is in idle function
Status
Receive
Grant
PHY transmitting status information to Link
PHY receiving data from the Link
PHY allows Link to transmit data
This is the operation by which, after Grant, the Link obtains the right to control the interface.
Table 4-4. CTL Controls Link
CTL0,CTL1
Type
Content
00
01
Idle
Link completes the packet transmission and releases the PHY/Link interface.
1) Link transmits Hold until the data is ready for transmission.
2) Link transmits the interface connect packet.
Link transmits the data to PHY.
Hold
10
11
Transmit
-
Not used.
4.3.2 LREQ
Access to the PHY register and the bus is controlled from the Link layer controller through the LREQ pin of PHY.
Figure 4-3. LREQ and CTL Timing
LREQ
(n-2)
(n-1)
LR0
LR1
LR2
LR3
LR
LR
CTL0,CTL1
A
B
C
C
A
C
C
: CTL before generation of LREQ
: CTL during LREQ execution
B
23
Data Sheet S14452EJ1V0DS00
µPD72850A
(1) LREQ format
• Bus Request
Table 4-5. Bus Request Format
Content
Bit
Type
0
start
Signal that starts a request : 1
Bus request type:
1-3
4-6
7
request
000: ImmReq acknowledge packet transmit
001: IsoReq isochronous packet transmit
010: PriReq cycle start packet transmit
011: FairReq asynchronous packet transmit
Transmit speed:
speed
000: 100 Mbps
010: 200 Mbps
100: 400 Mbps
other: reserved
stop
End request signal : 0 (optional)
• PHY Register Read Request
Table 4-6. Read Request Register Format
Bit
Type
Content
0
start
Signal that starts a request : 1
Read Request.
1-3
request
100 : ReadReq
4-7
8
access address
stop
PHY register address.
End request signal : 0
• PHY Register Write Request
Table 4-7. Write Request Register Format
Bit
Type
Content
0
start
Signal that starts a request : 1
Write Request.
1-3
request
101 : WriteReq
4-7
8-15
16
access address
write data
stop
PHY register address.
Write data.
End request signal : 0
24
Data Sheet S14452EJ1V0DS00
µPD72850A
• Acceleration Controller
Table 4-8. Acceleration Controller Request Format
Bit
Type
Content
Signal that starts a request : 1
0
start
1-3
4
request
110 : Acc Ctrl accelerate controller
access address
0: Accelerate disable
1: Accelerate enable
End request signal : 0
5
stop
Table 4-9. Request Type List
Bit
Type
Content
000
001
ImmReq
Used to acknowledge packet transmit.
When Idle is detected, PHY immediately controls the bus.
Used to transmit isochronous packet.
IsoReq
PHY does arbitration after isochronous gap is detected and acquires the bus.
010
011
100
101
110
111
PriReq
FairReq
RdReg
WrReg
AccCtrl
-
Used for Cycle master request.
Fair request.
PHY register read request.
PHY register write request.
Disable/enable of arbitration acceleration.
Unused.
For the Link to execute Priority request and Fair, start the request using LREQ when CTL0,CTL1 becomes
idle, after one clock. When request is acknowledged, the µPD72850A outputs Grant to CTL0,CTL1.
The Link of cycle master uses PriReq to transmit the cycle start packet. IsoReq transmits the isochronous
packet.
IsoReq becomes effective only as follows:
• The transmission of the cycle start packet is performed on the same isochronous period as Receive. (The
period until the subaction gap is detected.)
• During isochronous packet Transmit or Receive.
The µPD72850A cancels IsoReq with the subaction gap detection or bus reset. To meet the timing, do not
issue the IsoReq to PHY when CRC operation is performed.
The Link cancel method is described later.
After the packet is received, Link issues ImmReq as the acknowledge packet transmission. The purpose is to
prevent another node from detecting subaction gap as ACK_RESPONSE_TIME. The µPD72850A acquires
the bus after packet receive and returns Grant to CTL0,CTL1. When CRC fails, before Link detects Grant,
assert 3 Idle cycles to CTL0,CTL1.
When the bus reset is generated, the unprocessed requests are canceled.
The µPD72850A updates the data of the Write request register and the contents of the Read register are
changed. The contents of the register of the specified address are output to the Link as a status transfer in the
Read request register, When the status transmission is interrupted by transmitting/receiving packets, the
status transmission will re-start from the first bit after completing the transmit/receive of the packets.
25
Data Sheet S14452EJ1V0DS00
µPD72850A
The bus request (ImmReq, IsoReq, PriReg, FairReq) is completed (in case of ImmReq, IsoReq, when the
subaction gap is detected) when the packet is transmitted or canceled by canceling the bus request.
(2) LREQ rules
The Link request and the status of the serial bus are asynchronous; the bus request can be canceled by the
status of the serial bus.
The following rules apply to a request by LREQ:
• Link cannot issue a bus request (ImmReq, IsoReq, PriReq, FairReq) if Grant is given to an LREQ request or
until the Link’s request is canceled. The request can be canceled by the µPD72850A if it detects subaction
gap at ImmReq, IsoReq.
• Do not issue a RdReg or WrReg request when the status transmission is not completed by the Read request
register.
• All of the bus requests (ImmReq, IsoReq, PriReq, FairReq) are canceled by a bus reset.
In addition, there is a limitation in the request of LREQ according to the state of CTL as shown in Table 4-10.
Table 4-10. Rules for Other Requests
Request
State of CTL in CA to
which LREQ is allowed
when PHY drives CTL
LREQ issues
permission when Link
drives CTL
Note
Fair, Priority
Immediate
Idle, Status
wrong
Fair, Priority request cannot be issued until the
unprocessed bus request is completed.
Receive, Idle
wrong
Link issues the request after completing the decoding of
Destination_ID, when the acknowledge packet is ready.
After the packet is received, it is necessary to transmit the
first bit of the request within four cycles.
Isochronous
any
correct
If the isochronous packet transmission is prepared for the
isochronous period, it is issued.
Do not issue the request to transmit the isochronous
packet appending to the currently transmitted isochronous
packet (Using Hold).
Register Read
Register Write
AccCtrl
any
any
correct
correct
Do not issue this request if the unprocessed Read request
has not been completed.
To set acceleration bit 0:
When the isochronous period starts, if the Enab_accel bit
is one, Cycle slave should adjust accelerate bit to 0.
To set acceleration bit 1:
Do not set the cycle master.
It is issued when the isochronous period ends.
26
Data Sheet S14452EJ1V0DS00
µPD72850A
Table 4-11. PHY Operation Before LREQ Request to the CTL Function Changes
Request
State of CTL in C B after
LREQ was issued
Operation of the PHY (µPD72850A)
Fair, Priority
Receive
• Hold the request if the acceleration of arbitration packet transmitted with
enable is 8 bits (ACK).
Except for 8 bits, the requests are ignored.
• Ignore the request when the acceleration of arbitration is disabled.
Arbitration Won.
Grant
Idle, Status
Excluding when the bus reset is generated, Hold the requests.
Immediate
Grant
Receive
The packet is being transmitted to Link. Request Hold.
Excluding when the bus reset is generated, hold the request.
Request Hold.
Idle, Status
Isochronous
Transmit Idle (driven by Link)
Grant
Arbitration Won.
Receive
Status
Request Hold.
Request is ignored when sub-action gap is detected.
Idle
Register Read
Any (driven by Link)
Grant
Request Hold.
Receive
Status
Request Hold.
Hold the request until the corresponding register value is returned.
Idle
Register Write, Any
Acceleration
control
Request is completed.
4.3.3 PHY/Link Interface Timing
(1) SCLK timing
Table 4-12. SCLK Timing
Timing Constant
Comment
MIN.
2
MAX.
9
Unit
BUS_TO_LINK_DELAY
Period from receiving RX_DATA_PREFIX until
Receive to CTL is output.
SCLK cycle
DATA_PREFIX_TO_GRANT Period when the Grant is output to CTL after
TX_DATA_PREFIX is output to a port.
25
5
SCLK cycle
SCLK cycle
LINK_TO_BUS_DELAY
Period when TX_DATA_END is output to all ports
after transmitting the packet by Link after idle was
asserted to CTL.
2
MAX_HOLD
Maximum period when Hold can be asserted by Link
to confirm Grant.
47
SCLK cycle
27
Data Sheet S14452EJ1V0DS00
µPD72850A
(2) AC timing
Table 4-13. PHY/Link Interface Timing
Parameter
D, CTL propagation delay
Symbol
tpd
tsu
th
MIN.
0.5
6
MAX.
13.5
Unit
ns
D, CTL, LREQ setup time
D, CTL, LREQ Hold time
ns
0
ns
Figure 4-4. PHY/Link Interface AC Timing
SCLK
pd
pd
pd
t
t
t
D, CTL
SCLK
su
h
t
t
D, CTL, LREQ
4.4 Acceleration Control
Enable of ack-acceleration and fly-by on the same isochronous period may create a problem. The isochronous
cycle may extend unintentionally when transmitting the asynchronous packet by a node using ack-acceleration and
fly-by.
To avoid this problem, Link should control Disable/Enable of these enhancements (ack-Acceleration, fly-by), by
Acceleration Control requests. Cycle master cannot issue the Acceleration Control request.
The enhancements should not be used from the generation of the local cycle synchronization event to the
confirmation of cycle start. In this period, all Links except for Cycle Master use Acceleration Control as follows:
• Do not issue Fair nor Priority request to Link after generating local cycle synchronization, if the Acceleration
Control request’s Accelerate bit is not set to 0.
• Link must not use Hold when transmitting continuous primary asynchronous packet after the Acknowledge
packet, except after ack_pending to complete the split transaction.
• Ending the Link during the isochronous period issues the acceleration control request to set the Accelerate bit to
1, enabling these enhancements.
The µPD72850A does not require setting the Acceleration Control during isochronous transmit to enable the
isochronous request fly-by acceleration.
It is not necessary to issue Acceleration Control request when the cycle master is absent from the serial bus.
These enhancements are enabled if the Enab_accel bit in the PHY register is set. The µPD72850A supports Variable
Acceleration controlled by the Acceleration Control during power-on reset.
28
Data Sheet S14452EJ1V0DS00
µPD72850A
4.5 Transmit Status
Pin D0,D1 of the µPD72850A transmits status information to the Link. Status is asserted to CTL while transmitting
Status. The status transmission is interrupted if the serial bus receives a packet which contains states other than
status to CTL. Between two status transmissions, assert Idle to CTL for at least one SCLK cycle.
The µPD72850A transmits status in 16 bits as follows:
• In response to the register request
• After deciding the new Physical_ID for the Self_ID period resetting the bus (after a Self_ID packet is transmitted)
The event indication is the only 4-bit transmission of the µPD72850A.
Figure 4-5. Status Timing
PHY CTL0,CTL1
PHY D0-D7
00
00
01
01
01
00
00
00
00
S14,
S15
S0,S1
S2,S3
Table 4-14. Status Data Format
Bit(s)
Name
ARB_RESET_GAP
SUBACTION_GAP
BUS_RESET_START
Phy_interrupt
Description
0
1
2
3
Arbitration Reset gap detect
Subaction gap detect
Bus reset detect
Either of the following states is detected:
• The topology of the bus is a loop
• Voltage drop on the power cable
• Arbitration state machine timeout
• Port Event
4-7
Address
Data
PHY register address
8-15
Register data
The bits already transmitted are set to 0.
Example If the status transmission is interrupted after S0,S1 bit was transmitted, then in the next status transfer,
S0,S1 becomes 0.
Therefore one of the following situations will occur when the µPD72850A re-transmits status after an
interruption of the status transmission:
• At least one bit of S0-S3 is 1
• The PHY register data contains the interrupt status information
The status transmission always begins with S0,S1.
If the Link executes read request, and Subaction gap and arbitration reset gap are detected, priority is given to the
transmission of gap status, postponing the response to the register read request.
29
Data Sheet S14452EJ1V0DS00
µPD72850A
4.6 Transmit
The µPD72850A arbitrates the serial bus using Link’s LREQ.
• When the µPD72850A acquires the bus, a Grant period of 1 SCLK is executed to CTL0,CTL1. After that, an Idle
period of 1 SCLK cycle is executed.
• Link controls the interface executing Idle, Hold of Transmit to CTL0,CTL1 after 1 SCLK cycle when Grant from
PHY is detected.
• Before asserting Hold and Transmit, assert 1 Idle cycle. Do not execute Idle for 2 or more cycles.
• If the packet transmit is not ready, the Hold period can be extended up to MAX_HOLD.
• The µPD72850A outputs DATA_PREFIX to the serial bus while Hold is being asserted to CTL.
• When the packet transmit is ready, Link outputs the first bit of the packet and Transmit is asserted to CTL at the
same time.
• After transmitting the last bit of the packet, Link outputs for Idle or Hold to CTL for 1 cycle. After that, it outputs
Idle for 1 cycle.
When PHY/Link releases the bus, output Low to CTL and D0-D7 within 1 cycle.
Figure 4-6. Transmit Timing
(a) Single Packet
PHY CTL0,CTL1
PHY D0-D7
00
00
ZZ
ZZ
11
00
ZZ
ZZ
00
00
ZZ
ZZ
ZZ
ZZ
00
00
ZZ
ZZ
01
00
ZZ
ZZ
01
00
ZZ
ZZ
10
ZZ
ZZ
10
D1
ZZ
ZZ
10
ZZ
ZZ
10
ZZ
ZZ
00
00
ZZ
ZZ
00
00
00
00
ZZ
ZZ
Link CTL0,CTL1
Link D0-D7
n
D
D0
D2
(b) Concatenated Packet
PHY CTL0,CTL1
PHY D0-D7
ZZ
ZZ
10
ZZ
ZZ
10
ZZ
ZZ
01
ZZ
ZZ
00
00
00
00
ZZ
ZZ
00
00
ZZ
ZZ
11
00
ZZ
ZZ
00
00
ZZ
ZZ
ZZ
ZZ
00
00
ZZ
ZZ
01
00
ZZ
ZZ
10
ZZ
ZZ
10
ZZ
ZZ
01
00
Link CTL0,CTL1
Link D0-D7
n-1
n
D
D
SP
D0
D1
Note In case of packet transmission after Grant, before actual transmission, Hold does not need to be asserted.
Link can transmit continuous packets without releasing the bus.
• Hold is asserted to CTL. This function is used when the Link transmits continuous packets after acknowledge and
isochronous packets. Link outputs the transfer rate signal of the following packet to D0-D7 and asserts Hold
simultaneously.
• After Hold is detected by MIN_PACKET_SEPARATION, the µPD72850A outputs Grant to CTL.
30
Data Sheet S14452EJ1V0DS00
µPD72850A
• Link controls the interface by generating Idle, Hold or Transmit to CTL0,CTL1, after 1 SCLK cycle when Grant
from PHY is detected.
• Assert 1 Idle cycle before asserting Hold and Transmit (do not output 2 or more Idle cycles). When the packet
transmission is not ready, assert Hold. The Hold output period after Grant is detected should not exceed the
period provided by MAX_HOLD.
The following limitations exist though Link can transmit the concatenated packet with a different transfer rate. Link
cannot transmit other than S100 connecting packets after S100 (concatenated) packets have been transmitted. A
new request to transmit must be issued in order to transmit S100 packets at a transfer rate of S200 or more.
If the En_Multi bit in the PHY register is 0, the µPD72850A assumes the same speed as the first packet, for all of
the concatenated packets.
At the end of packet transmission, Link asserts Idle to CTL for a period of 2 cycles.
After sampling Idle from Link, the µPD72850A asserts Idle to CTL for a period of 1 cycle.
4.7 Cancel
This section describes how Link operates, when after the bus has been acquired by the request of LREQ, there is
no data transmission. In this case, a Null packet with no data is transmitted to the serial bus (DATA_PREFIX →
DATA_END).
Following are two method for canceling the Link:
1. As explained in Section 4.6, the Link outputs Idle or Hold, then outputs Transmit to CTL after confirming Grant.
Here, the Link asserts Idle for two cycles to CTL, then switches to high impedance.
The µPD72850A confirms Cancel at the second Idle cycle. To prevent the bus from switching to high
impedance, a third Idle cycle is needed.
Figure 4-7. Link Cancel Timing (After Grant)
PHY CTL0,CTL1
PHY D0-D7
00
00
ZZ
ZZ
11
00
ZZ
ZZ
00
00
ZZ
ZZ
ZZ
ZZ
00
00
ZZ
ZZ
00
00
ZZ
ZZ
00
00
00
00
ZZ
ZZ
Link CTL0,CTL1
Link D0-D7
2. To cancel after asserting Hold, assert Idle between two cycles; it switches to high impedance. This method
cancels the packet transmission connection (concatenated) after Grant is received. The µPD72850A cancels
with the next Idle cycle of Hold. To prevent CTL from switching to high impedance, assert a second Idle cycle.
31
Data Sheet S14452EJ1V0DS00
µPD72850A
Figure 4-8. Link Cancel Timing (After Hold)
PHY CTL0,CTL1
PHY D0-D7
00
00
ZZ
ZZ
11
00
ZZ
ZZ
00
00
ZZ
ZZ
ZZ
ZZ
00
00
ZZ
ZZ
01
00
ZZ
ZZ
01
00
ZZ
ZZ
00
00
ZZ
ZZ
00
00
00
00
ZZ
ZZ
Link CTL0,CTL1
Link D0-D7
4.8 Receive
This section shows the operation when the packet is received from the serial bus.
• When the µPD72850A detects DATA_PREFIX on the serial bus, it asserts receive to CTL and all of the D pins
assume the logic value of 1.
• The µPD72850A shows the speed code of the transfer rate ahead of the packet using bits D0-D7. Transmitting
the speed code with the speed signal is the protocol of the PHY/Link interface. The speed code is not included in
the CRC calculation.
• The µPD72850A continues to assert Receive to CTL until the packet is finally transmitted.
• Idle is asserted to CTL, indicating completion of the packet transmission.
Figure 4-9. Receive Timing
PHY CTL0,CTL1
00
00
10
10
10
10
10
10
00
00
00
00
(Binary)
PHY D0-D7
(Hex)
n
FF
FF
SP
D0
D1
D
The packet transfer rate of the serial bus depends on the topology of the bus. The µPD72850A checks if the node
can receive at the faster transfer rate. At this time, DATA_PREFIX → DATA_END is transmitted to the µPD72850A.
After DATA_PREFIX is transmitted to the Link, Receive from the serial bus is completed, asserting Idle.
Table 4-15 shows the speed code encoding.
Table 4-15. Speed Encoding
D0-D7
Data rate
Transmitted
00000000
01000000
01010000
11111111
Observed
00xxxxxx
0100xxxx
01010000
11xxxxxxxx
S100
S200
S400
Data Prefix
32
Data Sheet S14452EJ1V0DS00
µPD72850A
5. CABLE PHY PACKET
The node on the serial bus transmits and receives the PHY packet to control the bus.
The PHY packet is composed of 2 quadlets (64-bit); the second quadlet (32-bit) contains the inverse value of the
first quadlet.
The PHY packet is transmitted at a transfer rate of S100. All of the PHY packets received from the serial bus are
transmitted to the Link.
Though the PHY packet from the µPD72850A is transmitted to the Link, the PHY packet which was transmitted
from the Link of the node is not transmitted to the Link.
There are four types of PHY packets, as follows:
• Self_ID packet
• Link-on packet
• PHY configuration packet
• Extended PHY packet
The Self_ID packet transmitted automatically by the µPD72850A is also transmitted to the Link of a local node.
The µPD72850A PHY packet Receive from the serial bus operates similar to the PHY packet transmitted by the
Link (when the packet transmission to the Link is executed).
5.1 Self_ID Packet
During the Self_ID phase of the initialization or when the Ping packet responds, the µPD72850A transmits the
Self_ID packet.
Figure 5-1. Self_ID Packet Format
10
phy_ID
0
L
gap_cnt
sp
rsv
c
pwr
p0
p1
p2
i
m
Logical Inverse of the first quadlet
Table 5-1. Self_ID Packet
Field
Description
phy_ID
Physical ID of the node.
L
Logical product of Link_active and LPS in the PHY register.
Gap_count value in the PHY register.
gap_cnt
sp
c
Physpeed 10 (corresponds to 98.304, 196.608, 393.216 Mbps).
C bit values in the PHY register.
pwr
pwr value in the PHY register.
000: The node does not need the power supply. No power repeat.
001: Obtains power supply for the node. Can supply 15W or more.
010: Obtains power supply for the node. Can supply 30W or more.
011: Obtains power supply for the node. Can supply 45W or more.
100: The node consumes 3W maximum power.
110: The node consumes 3W maximum power. At least 3W are necessary to enable Link.
111: The node consumes 3W maximum power. At least 7W are necessary to enable Link.
i
It shows that the node issued Bus Reset and the bus was reset.
m
rsv
Read as 0.
Read as 00.
33
Data Sheet S14452EJ1V0DS00
µPD72850A
5.2 Link-on Packet
The µPD72850A outputs the Link-on signal of 6.144 MHz from the pin LKON when receiving the Link-on packet.
Figure 5-2. Link-on Packet Format
01
phy_ID
0000
0000
0000
0000
0000
0000
Logical Inverse of the first quadlet
Table 5-2. Link-on Packet
Field
Description
phy_ID
Physical_ID of the destination of the Link-on packet
5.3 PHY Configuration Packet
Use the PHY configuration packet to set the gap count for the bus.
Figure 5-3. PHY Configuration Packet Format
gap_cnt 0000 0000
Logical Inverse of the first quadlet
00
root_ID
R
T
0000
0000
Table 5-3. PHY Configuration Packet
Field
Description
root_ID
R
Sets the Physical_ID node as root contender (for the next reset).
When this bit is set to 1 and the Phyisical_ID of the node corresponds to the rootID of this packet, the
µPD72850A sets the force_root bit. The force_root bit is cleared if there is discrepancy.
If this bit is 1, the gap_cnt value of this packet is used as the gap_count value. The gap_count value
must not be cleared by the following bus reset, set the gap_count_reset_disable flag in the µPD72850A
to TRUE.
T
gap_cnt
When this packet is received, the gap count is set to this value. While it remains effective for the next
bus reset, it will be cleared by the second bus reset to 3FH.
Remark Applying 0 to both R,T, regards the following packets as extended PHY packets, the PHY configuration is
not recognized.
5.4 Extended PHY Packet
An extended PHY packet is defined when both the R (in the PHY configuration packet) and T bits are transmitted
as 0. The extended PHY packet does not influence the force_root_bit and the gap_count bit on any node.
Following are the types of extended PHY packets:
• Ping packet
• Remote access packet
• Remote reply packet
• Remote command packet
• Remote confirmation packet
• Resume packet
34
Data Sheet S14452EJ1V0DS00
µPD72850A
5.4.1 Ping Packet
When the µPD72850A receives the Ping packet, it will transmit the Self_ID packet within the RESPONSE_TIME.
Figure 5-4. Ping Packet Format
00
phy_ID
00
type (0)
00
0000
0000
0000
0000
Logical Inverse of the first quadlet
Table 5-4. Ping Packet
Field
Description
phy_ID
type
Physical ID of the destination node of the Ping packet
Indicates that there is a Ping packet with a value of 0
5.4.2 Remote Access Packet
The Remote access packet reads information in the PHY register of another node. The PHY specified by the
Remote access packet transmits the value in the register using the Remote Reply packet.
Figure 5-5. Remote Access Packet Format
00
phy_ID
00
type
page
port
reg
reserved
Logical Inverse of the first quadlet
Table 5-5. Remote Access Packet
Field
Description
phy_ID
type
page
port
Physical ID of the destination node of the Remote access packet
1 = read register (base register), 5 = read register (page register)
Specifies the page of the PHY register
Specifies the register of each port in the PHY register
Specifies the address when reading the base register.
reg
In case of the Page and port registers, specifies the address with 1000+reg.
35
Data Sheet S14452EJ1V0DS00
µPD72850A
5.4.3 Remote Reply Packet
The µPD72850A transmits the value in the register by using the Remote reply packet as a response to the Remote
access packet.
Figure 5-6. Remote Reply Packet Format
00
phy_ID
00
type
page
port
reg
data
Logical Inverse of the first quadlet
Table 5-6. Remote Reply Packet
Field
Description
phy_ID
type
page
port
Physical ID of the node (Node’s original packet transmit)
3 = register read (base register), 7 = read register (page register)
Used when specifying the page of the PHY register
Used to specify the register of each port in the PHY register
Specifies the address when reading the base register.
reg
In case of the Page and port registers, specify the address with 1000+reg.
Contents of the specified register
data
5.4.4 Remote Command Packet
Use the Remote command packet to operate the function of the port of the PHY of another node.
Figure 5-7. Remote Command Packet Format
00
phy_ID
00
type(8)
000
port
0000
0000
cmnd
Logical Inverse of the first quadlet
Table 5-7. Remote Command Packet
Field
Description
phy_ID
type
Physical ID of the destination packet
Extended PHY packet type; set to 8 for Remote command packet
port
Port of the PHY of the operating node
cmnd
Command
0: NOP
1: Disables the port after transmission of the TX_DISABLE_NOTIFY
2: Suspend initiator
4: Clears to 0 the Fault bit of the port
5: Enables the port
6: Resumes the port
36
Data Sheet S14452EJ1V0DS00
µPD72850A
5.4.5 Remote Confirmation Packet
The µPD72850A transmits the Remote confirmation when the Remote command packet is received, responding
whether Cmnd can be executed.
Figure 5-8. Remote Confirmation Packet Format
00
phy_ID
00
type(A16)
000
port
000
f
c
b
d
ok
cmnd
Logical Inverse of the first quadlet
Table 5-8. Remote Confirmation Packet
Field
Description
phy_ID
Physical ID of the node (node’s original packet transmit)
Extended PHY packet type; set to A16 for Remote confirmation packet
Port set from the Remote command packet
type
port
f
Fault bit value of the PHY register of this port
c
Connected bit value of the PHY register of this port
Bias bit value of the PHY register of this port
b
d
Disable bit value of the PHY register of this port
1 indicates executing; otherwise it is 0
ok
cmnd
Specifies the command value with the Remote command packet
5.4.6 Resume Packet
When the µPD72850A receives the Resume packet, all of the ports that were suspended resume the connection.
The Resume packet does the broadcast.
Figure 5-9. Resume Packet Format
00
phy_ID
00
type (F16)
00
0000
0000
0000
0000
Logical Inverse of the first quadlet
Table 5-9. Resume Packet
Field
Description
phy_ID
type
Physical ID of the original packet transmit
Extended PHY packet type; set to F16 for Resume packet
37
Data Sheet S14452EJ1V0DS00
µPD72850A
6. ELECTRICAL SPECIFICATIONS
Absolute Maximum Ratings
Parameter
Power supply voltage
Input voltage
Symbol
Condition
Rating
Unit
VDDm
VIN
–0.5 to +4.6
–0.5 to VDD+0.5
–0.5 to VDD+0.5
–40 to +125
V
V
Output voltage
VOUT
Tstg
V
Storage temperature
°C
Caution Product quality may suffer if the absolute maximum rating is exceeded even momentarily for any
parameter. That is, the absolute maximum ratings are rated values at which the product is on the
verge of suffering physical damage, and therefore the product must be used under conditions that
ensure that the absolute maximum ratings are not exceeded.
Recommended Operating Ranges
Parameter
Power supply voltage
Symbol
VDD
Condition
MIN.
3.0
TYP.
3.3
MAX.
3.6
Unit
V
Operating temperature
Power dissipation
TA
0.0
70.0
0.9
°C
W
PD
38
Data Sheet S14452EJ1V0DS00
µPD72850A
DC Characteristics
Common
Parameter
Symbol
IDD
Condition
MIN.
TYP.
135
MAX.
240
Unit
mA
mA
Supply current
3-port, S400, VDD = 3.6 V
1-port transmit or receive,
S400, VDD = 3.3 V
PHY/Link Interface
Parameter
Symbol
VOH
Condition
IOH = –4 mA
IOH = –9 mA
IOH = 4 mA
MIN.
2.8
TYP.
MAX.
Unit
V
High-level output voltage (Undifferentiated)
High-level output voltage (Differentiated)
Low-level output voltage (Undifferentiated)
Low-level output voltage (Differentiated)
High-level input voltage (Undifferentiated)
Low-level input voltage (Undifferentiated)
Input rising threshold voltage (LPS)
Input falling threshold voltage (LPS)
VOHD
VOL
VDD–0.4
V
0.4
0.4
V
VOLD
VIH
IOH = 9 mA
V
2.6
V
DD+10%
V
VIL
0.7
V
VLIT+
VLIT-
VLREF+1
V
VLREF
+0.2
VREF
+0.3
VREF
–0.9
V
Hysteresis input rising threshold
voltage(Differentiated)
Hysteresis input falling threshold
voltage(Differentiated)
Reference voltage
VIT+
VREF
+0.9
VREF
–0.3
V
V
VIT-
VREF
VLREF
CIN
VDD/2±1%
V
V
Reference voltage (LPS)
Input capacitance
0.5
1.6
7.5
pF
Cable Interface
Parameter
Symbol
VID
Condition
MIN.
142
TYP.
MAX.
260
Unit
mV
mV
mV
V
Differential input voltage
Cable input, 100 Mbps operation
Cable input, 200 Mbps operation
Cable input, 400 Mbps operation
100 Mbps speed signaling off
200 Mbps speed signaling
400 Mbps speed signaling
132
260
118
260
TpB common mode input voltage
VICM
1.165
0.935
0.523
172.0
1.665
1.438
1.030
–0.81
–4.84
–12.40
2.515
2.515
2.515
265.0
2.015
2.015
2.015
+0.44
–2.53
–8.10
7.5
V
V
Differential output voltage
VOD
Cable output (Test load 55
Ω
)
mV
V
TpA common mode output voltage
VOCM
100 Mbps speed signaling off
200 Mbps speed signaling
400 Mbps speed signaling
100 Mbps speed signaling off
200 Mbps speed signaling
400 Mbps speed signaling
CPS
V
V
TpA common mode output current
ICM
mA
mA
mA
V
Power status threshold voltage
TpBias output voltage
VTH
VTPBIAS
1.665
2.015
V
39
Data Sheet S14452EJ1V0DS00
µPD72850A
AC Characteristics
PHY/Link Interface
Parameter
D, CTL, LREQ setup time
D, CTL, LREQ hold time
D, CTL output timing
SCLK cycle time
Symbol
tSU
Condition
MIN.
6
TYP.
MAX.
12
Unit
ns
ns
ns
ns
ns
ns
ns
tHD
0
tD
2
tSCLK
tSCLKH
tSCLKL
tLINKON
20
9
SCLK high level time
SCLK low level time
LKON cycle time
11
11
9
160
Link Interface Timing (SCLK, LKON)
SCLK
tSCLKH
tSCLKL
tSCLK
LKON
tLINKON
40
Data Sheet S14452EJ1V0DS00
µPD72850A
Link Interface Timing (CTL, D)
SCLK
tD
tD
tD
Transmit
CTL0,CTL1
tD
tD
tD
D0-D7
tSU
tH
Receive
CTL0,CTL1
tSU
H
t
D0-D7
Link Interface Timing (LREQ)
SCLK
tSU
tH
LREQ
41
Data Sheet S14452EJ1V0DS00
µPD72850A
Cable Interface
Parameter
Symbol
tJITTER
tSKEW
Condition
MIN.
TYP.
MAX.
±0.15
±0.10
1.2
Unit
ns
TpA, TpB transfer jitter
Between TpA and TpB
Between TpA and TpB
10% to 90%, via 55Ω and
10 pF
TpA strobe, TpB data transfer
TPA, TPB rise time/fall time
ns
tR/tF
ns
42
Data Sheet S14452EJ1V0DS00
µPD72850A
7. APPLICATION CIRCUIT EXAMPLE
7.1 IEEE1394 Interface
Note
Note
Note
µ
µ
µ
µ
µ
µ
µ
AGND
AGND
AVDD 40
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
µ
0.1
F
AGND
XO
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
DD
AV
10 pF
10 pF
PORTDIS
AGND
XI
DD
AV
0.1 µF
PSEL
FIL0
FIL1
DD
AV
µ
F
0.1
AGND
AGND
AGND
AGND
µ
F
0.1
DD
AGND
AV
µ
F
0.1
SUS/RES
AGND
RESETB
DGND
µ
22
F
µ
DD
AV
DD
DV
µ
F
0.1
µ
0.1
0.1
F
DD
DV
DGND
IC(H)
DD
DV
µ
IC(H)
D7
D6
µ
F
DIRECT
LKON
PC2
DGND
D5
µ
DD
DV
D4
µ
µ
µ
µ
µ
µ
µ
Note Common mode choke.
Recommendation : TOKO Part No.857CM-0009 (TYPE B5W)
43
Data Sheet S14452EJ1V0DS00
µPD72850A
7.2 NEC/FFM Board Sharing
AVDD
22 µF
AGND
0.1 µF
+
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
1
2
3
4
5
6
7
8
9
10
MD8405E
11
12
13
14
15
16
17
18
19
20
AGND
µ
F
0.33
µ
F
µ
F
0.33
0.33
Vp
1.8 kΩ
220 kΩ
11 kΩ
2.7 kΩ
18 kΩ
AVDD
0.1 µF
33 pF
AGND
MD8405E (FUJIFILM MICRODEVICED CO.,LTD)
220 pF
510 Ω 620 Ω
AVDD
0.1 µF
+
22 µF
AGND
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
µPD72850A
AGND
µ
1 . 0
F
1 . 0
µ
µ
F
F
1 . 0
Vp
390 kΩ
9.1 kΩ
AVDD
AGND
44
Data Sheet S14452EJ1V0DS00
µPD72850A
8. PACKAGE DRAWING
80-PIN PLASTIC TQFP (FINE PITCH) (12x12)
A
B
60
41
61
40
detail of lead end
S
C
D
Q
R
80
21
1
20
F
G
J
M
I
H
K
P
S
N
S
L
M
NOTE
Each lead centerline is located within 0.10 mm of
its true position (T.P.) at maximum material condition.
ITEM MILLIMETERS
A
B
C
D
F
G
H
I
14.0±0.2
12.0±0.2
12.0±0.2
14.0±0.2
1.25
1.25
0.22±0.05
0.10
J
0.5 (T.P.)
1.0±0.2
0.5±0.2
0.145±0.05
0.10
K
L
M
N
P
Q
1.0±0.05
0.1±0.05
+7°
3°
R
S
−3°
1.2 MAX.
S80GK-50-9EU-1
45
Data Sheet S14452EJ1V0DS00
µPD72850A
9. RECOMMENDED SOLDERING CONDITIONS
The µPD72850A should be soldered and mounted under the following recommended conditions.
For the details of the recommended soldering conditions, refer to the document Semiconductor Device Mounting
Technology Manual (C10535E).
For soldering methods and conditions other than those recommended below, contact your NEC sales
representative.
Table 9-1. Surface Mounting Type Soldering Conditions
µPD72850AGK-9EU : 80-pin plastic TQFP (Fine pitch) (12 x 12 mm)
Soldering
Method
Soldering Conditions
Recommended
Condition Symbol
Infrared reflow
Package peak temperature: 235°C, Time: 30 sec. Max. (at 210°C or higher).
Count: three times or less
IR35-103-3
Exposure limit: 3 daysNote (after that prebake at 125°C for 10 hours)
Partial heating
Pin temperature: 300°C Max., Time: 3 sec. Max. (per pin row)
—
Note After opening the dry pach, store it at 25°C or less and 65% RH or less for the allowable storage period.
46
Data Sheet S14452EJ1V0DS00
µPD72850A
NOTES FOR CMOS DEVICES
1
PRECAUTION AGAINST ESD FOR SEMICONDUCTORS
Note:
Strong electric field, when exposed to a MOS device, can cause destruction of the gate oxide and
ultimately degrade the device operation. Steps must be taken to stop generation of static electricity
as much as possible, and quickly dissipate it once, when it has occurred. Environmental control
must be adequate. When it is dry, humidifier should be used. It is recommended to avoid using
insulators that easily build static electricity. Semiconductor devices must be stored and transported
in an anti-static container, static shielding bag or conductive material. All test and measurement
tools including work bench and floor should be grounded. The operator should be grounded using
wrist strap. Semiconductor devices must not be touched with bare hands. Similar precautions need
to be taken for PW boards with semiconductor devices on it.
2
HANDLING OF UNUSED INPUT PINS FOR CMOS
Note:
No connection for CMOS device inputs can be cause of malfunction. If no connection is provided
to the input pins, it is possible that an internal input level may be generated due to noise, etc., hence
causing malfunction. CMOS devices behave differently than Bipolar or NMOS devices. Input levels
of CMOS devices must be fixed high or low by using a pull-up or pull-down circuitry. Each unused
pin should be connected to VDD or GND with a resistor, if it is considered to have a possibility of
being an output pin. All handling related to the unused pins must be judged device by device and
related specifications governing the devices.
3
STATUS BEFORE INITIALIZATION OF MOS DEVICES
Note:
Power-on does not necessarily define initial status of MOS device. Production process of MOS
does not define the initial operation status of the device. Immediately after the power source is
turned ON, the devices with reset function have not yet been initialized. Hence, power-on does
not guarantee out-pin levels, I/O settings or contents of registers. Device is not initialized until the
reset signal is received. Reset operation must be executed immediately after power-on for devices
having reset function.
47
Data Sheet S14452EJ1V0DS00
µPD72850A
FireWire is a trademark of Apple Computer, Inc.
i.LINK is a trademark of Sony Corporation.
The export of this product from Japan is prohibited without governmental license. To export or re-export this product from
a country other than Japan may also be prohibited without a license from that country. Please call an NEC sales
representative.
• The information in this document is subject to change without notice. Before using this document, please
confirm that this is the latest version.
• No part of this document may be copied or reproduced in any form or by any means without the prior written
consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which may appear in
this document.
• NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual property
rights of third parties by or arising from use of a device described herein or any other liability arising from use
of such device. No license, either express, implied or otherwise, is granted under any patents, copyrights or other
intellectual property rights of NEC Corporation or others.
• Descriptions of circuits, software, and other related information in this document are provided for illustrative
purposes in semiconductor product operation and application examples. The incorporation of these circuits,
software, and information in the design of the customer's equipment shall be done under the full responsibility
of the customer. NEC Corporation assumes no responsibility for any losses incurred by the customer or third
parties arising from the use of these circuits, software, and information.
• While NEC Corporation has been making continuous effort to enhance the reliability of its semiconductor devices,
the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or
property arising from a defect in an NEC semiconductor device, customers must incorporate sufficient safety
measures in its design, such as redundancy, fire-containment, and anti-failure features.
• NEC devices are classified into the following three quality grades:
"Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on a
customer designated "quality assurance program" for a specific application. The recommended applications of
a device depend on its quality grade, as indicated below. Customers must check the quality grade of each device
before using it in a particular application.
Standard: Computers, office equipment, communications equipment, test and measurement equipment,
audio and visual equipment, home electronic appliances, machine tools, personal electronic
equipment and industrial robots
Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster
systems, anti-crime systems, safety equipment and medical equipment (not specifically designed
for life support)
Specific: Aircraft, aerospace equipment, submersible repeaters, nuclear reactor control systems, life
support systems or medical equipment for life support, etc.
The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books.
If customers intend to use NEC devices for applications other than those specified for Standard quality grade,
they should contact an NEC sales representative in advance.