NDU4316E [NICHIA]

Ultra Violet Laser Diode; 紫外激光二极管
NDU4316E
型号: NDU4316E
厂家: NICHIA CORPORATION    NICHIA CORPORATION
描述:

Ultra Violet Laser Diode
紫外激光二极管

二极管 激光二极管
文件: 总3页 (文件大小:350K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
[
UTZ-SC0334_2  
2012/10/02  
]
Ultra Violet Laser Diode  
Engineering Sample  
NDU4316E  
• Optical Output Power: CW120mW  
• Peak Wavelength: 390-400nm  
Outline Dimension  
Features  
Unit (mm)  
Φ
Φ
• Can Type: φ 5.6 Floating Mounted with Photo Diode and Zener Diode  
(90°)  
Emitting Point  
(0.4)  
Absolute Maximum Ratings  
Absolute Maximum  
Ratings  
1.0±0.1  
Item  
Symbol  
Unit  
Z+  
Optical Output Power  
Allowable Reverse Current  
PD Reverse Voltage  
Po  
Ir (LD)  
Vr (PD)  
Tstg  
140  
85  
mW  
Φ
Φ
4.2±0.2  
3.55±0.1  
mA  
V
Emitting Point  
5
Reference Plane  
Storage Temperature  
-40 ~ 85  
-10 ~ 30  
°C  
°C  
Operating Case Temperature  
Tc  
Φ 0.43±0.08  
(Tc=25°C)  
Condition Symbol Min Typ. Max Unit  
Initial Electrical/Optical Characteristics  
3
Item  
X+  
1
2
Optical Output Power  
Peak Wavelength  
Threshold Current  
Operating Current  
Slope Efficiency  
Operating Voltage  
CW  
Po=120mW  
CW  
Po  
λp  
Ith  
-
390  
-
-
-
120  
400  
50  
mW  
nm  
mA  
mA  
W/A  
V
4
Φ
2.0±0.2  
Y+  
28  
100  
1.7  
4.5  
-
( ) are reference figures  
Po=120mW  
CW  
Iop  
-
150  
2.1  
Pin Connection  
1.3  
-
η
Vop  
θ//  
θ⊥  
∆θ//  
∆θ⊥  
Im  
Po=120mW  
5.5  
Parallel  
Beam  
7.0  
13.0  
-2.0  
-2.5  
-
12.0  
28.0  
2.0  
°
°
°
°
Po=120mW  
Divergence*  
Perpendicular  
Parallel  
-
-
Beam Pointing  
Accuracy  
Po=120mW  
Po=120mW  
Perpendicular  
-
2.5  
This model has a Zener Diode built in  
as a protection circuit against static  
electricity.  
Monitor Current**  
-
1.0  
mA  
* Full angle at 50% from peak intensity  
** Monitor Current is short time power reference purpose only. Not guaranteed for accuracy.  
All figures in this specification are measured by Nichia's method and may contain measurement deviations.  
This model is Engineering Sample for evaluation or design purpose only. Life time is not guaranteed.  
The above specifications are for reference purpose only and subjected to change without prior notice.  
Safety of Laser light  
Laser Light can damege the human eyes and skin. Do not expose the eye or skin to any  
laser light directly and/or through optical lens. When handling the LDs, wear appropriate  
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused  
laser beam through optical instruments will increase the chance of eye hazard.  
These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety  
Standards. It is absolutely necessary to take overall safety measures against User's  
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.  
HEAD OFFICE  
NICHIA CORPORATION  
http://www.nichia.co.jp  
P.O.BOX 6 ANAN, TOKUSHIMA-KEN 774-8601, JAPAN  
PHONE: +81-884-22-2311 FAX: +81-884-21-0148  
CONTACT  
TOKYO SALES OFFICE  
13F Tamachi Center Building 34-7, Shiba 5-Chome, Minato-Ku, TOKYO 108-0014, JAPAN  
PHONE: +81-3-3456-3108  
FAX: +81-3-5440-7330  
-1-  
[
UTZ-SC0334_2  
2012/10/02  
]
Typical Characteristics  
Optical Output Power vs. Forward Current  
Forward Voltage vs. Forward Current  
140  
120  
100  
80  
7
6
5
4
3
2
1
0
Tc=0ºC  
Tc=25ºC  
60  
40  
Tc=0ºC  
Tc=25ºC  
20  
0
0
20  
40  
60  
80 100 120 140  
0
20  
40  
60  
80 100 120 140  
Forward Current [mA]  
Forward Current [mA]  
Threshold Current vs. Case Temperature  
Peak Wavelength vs. Case Temperature  
45  
40  
35  
30  
25  
20  
15  
404  
402  
400  
398  
396  
394  
392  
390  
388  
-10  
0
10  
20  
30  
-10  
0
10  
20  
30  
º
º
Case Temperature [ C]  
Case Temperature [ C]  
Far Field Pattern  
Typical Spectrum  
θ//  
θ  
393  
394  
395  
396  
397  
398  
-40 -30 -20 -10  
0
10 20 30 40  
Wavelength [nm]  
Angle [°]  
-2-  
[
UTZ-SC0334_2  
2012/10/02  
]
Cautions  
(1) Operating method  
The LD shall change its forward voltage requirement and optical output power according to temperature change. Also, the  
LD will require more operation current to maintain same output power as it degrades. In order to maintain output power, use  
of APC (Automatic Power Control) is recommended, which use monitor feedback to adjust the operation current.  
Confirm that the optical output power generated by spike current when switching on and off does not exceed the maximum  
absolute rating. Also, employ appropriate countermeasures to reduce chattering and/or overshooting in the Circuit.  
(2) Static Electricity  
Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist  
strap or anti-electrostatic glove when handling the Product.  
(3) Absolute Maximum Rating  
Active layer of LDs shall have high current density and generate high electric field during its operation. In order to  
prevent excessive damage, the LD must be operated strictly below Absolute Max Rating.  
(4) Others  
Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as office equipment,  
communications equipment, measurement instruments and household appliances). Consult Nichia’s sales staff in advance  
for information on the applications in which exceptional quality and reliability are required, particularly when the failure or  
malfunction of the LDs may directly jeopardize life or health (such as for airplanes, aerospace, submersible repeaters,  
nuclear reactor control systems, automobiles, traffic control equipment, life support systems and safety devices).  
The Purchaser must acknowledge that any LD can be failed statically and must design its equipments fail safe design. Prior  
to use of the LD, please confirm that the LD, as described in Nichia’s specifications, meets the life expectancy needs of, and  
provides the features required by the Circuit and any related modules, equipment and/or systems.  
Nichia prohibit Purchaser from reverse engineering, disassembling, or taking any other steps to derive the structure or  
design of the LD.  
The appearance and specifications of the product may be modified for improvement without notice. The formal  
specifications must be exchanged and signed by both parties before large volume purchase begins.  
No unauthorized transmission or reproduction of this document, either in whole or in part, is permitted.  
-3-  

相关型号:

NDU502C1R10

Low cost, solid state temperature sensor
AMPHENOL

NDU502C1R3

Low cost, solid state temperature sensor
AMPHENOL

NDU502C1R5

Low cost, solid state temperature sensor
AMPHENOL

NDU502C2AR10

Low cost, solid state temperature sensor
AMPHENOL

NDU502C2AR3

Low cost, solid state temperature sensor
AMPHENOL

NDU502C2AR5

Low cost, solid state temperature sensor
AMPHENOL

NDU502C2R10

Low cost, solid state temperature sensor
AMPHENOL

NDU502C2R3

Low cost, solid state temperature sensor
AMPHENOL

NDU502C2R5

Low cost, solid state temperature sensor
AMPHENOL

NDU502C3R10

Low cost, solid state temperature sensor
AMPHENOL

NDU502C3R3

Low cost, solid state temperature sensor
AMPHENOL

NDU502C3R5

Low cost, solid state temperature sensor
AMPHENOL