PA-960-354P-R2-2 [NIDEC]

THIN-FILM HIGH PRESSURE TRANSDUCER;
PA-960-354P-R2-2
型号: PA-960-354P-R2-2
厂家: NIDEC COMPONENTS    NIDEC COMPONENTS
描述:

THIN-FILM HIGH PRESSURE TRANSDUCER

文件: 总4页 (文件大小:193K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
受圧部サージ圧防止構造の油圧用高圧センサ  
PA-960/PA-968  
THIN-FILM HIGH PRESSURE TRANSDUCER.  
INTERNAL STRUCTURE  
PA-960/PA-968  
1
2
3
4
Part name  
Material  
SUS 304  
FEATURES  
Case  
1
2
3
4
ꢀꢁCompact and lightweight  
Board  
ꢀꢁTo support maximum of 50 MPa(s).  
ꢀꢁDigital coverage for a high accuracy  
ꢀꢁMounting by connector for an easy wiring  
ꢀꢁ High water proof structure comply with IP67(when  
mounting connector)  
17-4PH  
Correspond to SUS630)  
17-4PH  
Correspond to SUS630)  
Sensor module  
Fitting  
ꢀꢁCE Marking available  
MODEL NUMBER DESIGNATION  
PA-960 - 104P - R2 - 1  
Series name  
Cable  
PA-960:  
BlankNothing)  
1(M12 connector cableStraight 1m)  
2(M12 connector cableAngle 1m)  
Voltage output  
PA-968:  
Current output  
Pressure range  
503P 5MPa104P  
354P 35MPa504P  
10MPa204P  
20MPa、  
50MPa)  
Fitting  
R2  
G3(  
G3/8  
R1/4  
G3/8included P14 O-ring)  
Please refer to the LIST OF MODEL NUMBERS when placing orders.  
PA-960/PA-968  
PRESSURE TRANSDUCERS WITH AMP.  
LIST OF MODEL NUMBERS  
Pressure range  
Series name  
Fitting  
Cable  
Reference)  
0 5MPa  
0 10MPa  
0 20MPa  
0 35MPa  
0 50MPa  
Nothing  
Straight  
Angle  
PA-960-503P-R2 PA-960-104P-R2 PA-960-204P-R2 PA-960-354P-R2 PA-960-504P-R2  
PA-960-503P-R2-1 PA-960-104P-R2-1 PA-960-204P-R2-1 PA-960-354P-R2-1 PA-960-504P-R2-1  
PA-960-503P-R2-2 PA-960-104P-R2-2 PA-960-204P-R2-2 PA-960-354P-R2-2 PA-960-504P-R2-2  
PA-960-503P-G3 PA-960-104P-G3 PA-960-204P-G3 PA-960-354P-G3 PA-960-504P-G3  
PA-960-503P-G3-1 PA-960-104P-G3-1 PA-960-204P-G3-1 PA-960-354P-G3-1 PA-960-504P-G3-1  
PA-960-503P-G3-2 PA-960-104P-G3-2 PA-960-204P-G3-2 PA-960-354P-G3-2 PA-960-504P-G3-2  
PA-968-503P-R2 PA-968-104P-R2 PA-968-204P-R2 PA-968-354P-R2 PA-968-504P-R2  
PA-968-503P-R2-1 PA-968-104P-R2-1 PA-968-204P-R2-1 PA-968-354P-R2-1 PA-968-504P-R2-1  
PA-968-503P-R2-2 PA-968-104P-R2-2 PA-968-204P-R2-2 PA-968-354P-R2-2 PA-968-504P-R2-2  
PA-968-503P-G3 PA-968-104P-G3 PA-968-204P-G3 PA-968-354P-G3 PA-968-504P-G3  
PA-968-503P-G3-1 PA-968-104P-G3-1 PA-968-204P-G3-1 PA-968-354P-G3-1 PA-968-504P-G3-1  
PA-968-503P-G3-2 PA-968-104P-G3-2 PA-968-204P-G3-2 PA-968-354P-G3-2 PA-968-504P-G3-2  
R1/4  
PA-960  
Voltage  
output)  
Nothing  
Straight  
Angle  
G3/8,included  
P14 O-ring  
Nothing  
Straight  
Angle  
R1/4  
PA-968  
Current  
output)  
Nothing  
Straight  
Angle  
G3/8,included  
P14 O-ring  
Verify the above model numbers when placing orders.  
STANDARD SPECIFICATIONS  
ꢀꢁUnless otherwise specified, the specs are defined at an ambient temperature of 25  
±
5 °C and excitation voltage of 12 V DC.  
PA-960/968  
Model  
Item  
number  
ꢀꢀꢀ503Pꢀꢀꢀꢀꢀꢀꢀ104Pꢀꢀꢀꢀꢀ ꢀ204Pꢀꢀꢀꢀꢀꢀ 354Pꢀꢀꢀꢀꢀ ꢀ504P  
Pressure reference  
Gauge  
Rated pressure range  
Maximum pressure  
Operating temp. range  
Compensated temp. range  
Operating humidity  
Storage temp.  
MPa  
MPa  
°C  
10  
20  
20  
40  
50  
65  
5
35  
50  
10  
PA - 960:- 20 ~ 85ꢀꢀPA - 968:- 20 ~ 70  
°C  
20 ~ 70  
%RH  
°C  
35 ~ 85No condensation)  
- 20 ~ 70(At atmospheric pressure, humidity below 65%RH)  
Gases/Liquids compatible with 17-4PH  
IP67*  
Pressure medium  
Protection grade  
Net weight  
g
Applox.60/Applox.130*  
Supply voltage  
10.8 ~ 30VDC(include ripple)  
10mA Max.No load/PA-960  
Consumption current  
*Including the attached cable  
PA-960/PA-968  
PRESSURE TRANSDUCERS WITH AMP.  
STANDARD SPECIFICATIONS  
Unless otherwise specified, the specs are defined at an ambient temperature of 25 5 °C, excitation voltage of 12 V DC, and Rated pressure of Pin=0 Pr.  
PA-960  
1 ~ 5V  
PA-968  
Item  
Model number  
Output voltage/Current  
Zero voltage/ Current  
Span voltage/Current  
Linearityꢀ  
4 ~ 20mA  
4±0.2mA  
16±0.2mA  
1±0.05V  
4±0.05V  
%F.S.  
%F.S.  
±0.5  
Hysteresisꢀ  
±0.1  
±0.2  
ZERO  
± 0.05  
± 0.05  
%F.S./°C  
Thermal Error  
(- 20 70℃)  
SPAN  
%F.S./°C  
Load resistance  
Response  
10kΩ 以上  
500Ω max.power supply24V**  
2ms Max.  
** Please refer to the following table or expression to choose load resistance.  
LOAD RESISTANCE  
Please refer to the following table or expression to  
choose load resistance of current output type (PA-968).  
Performance mapping  
Expression of the load resistance  
RLMAX)  
750  
Vopr10.8  
RLMAX)  
0.026  
500  
Vopr10.8  
250  
RLMIN)  
RLMIN)  
507.7  
0.026  
0
0
10.8  
24  
30  
Power supply Vopr VDC]  
ENVIRONMENTAL CHARACTERISTICS  
Test conditions  
Test item  
Permissible change  
Ta=25 5ꢀCꢁPin=0Mpa)  
10 ~ 500 Hz, 1.5 mm P-P,  
Vibration  
3 directions for 2 hours each  
490 m/s2  
Shock  
3 directions for 3 times each  
Analog output (Zero voltage/current, Span voltage/  
current:): 2 %F.S., maximum each after test  
106 cycles  
Pressure cycling  
Moisture resistance  
0 Rated pressure  
40 °C, 90 ~ 95 %RH, 240 hrs.  
Analog output (Zero voltage/current, Span voltage/  
current:): 5 %F.S., maximum each after test  
EMI : EN55011: 2007, A2 : 2007 Group 1, class B  
EMS : EN61326-1 : 2006/EN61326-2-3 : 2006 Table 2  
EMC  
PA-960/PA-968  
PRESSURE TRANSDUCERS WITH AMP.  
ꢀꢁPA-960  
INTERNAL CIRCUIT  
OUTLINE DIMENSIONS  
ꢀꢁFittingR2R 1/4)  
48.5  
±
1
10  
Pressure port  
With Snubber  
15.5  
5.7  
6.5 min  
Marking  
1
2
3
BrownPower(+)  
Black Analog Output  
Pressure  
Sensor  
Main circuit  
-
-
-
PA 96 104P R2  
Blue Common  
*
Lot.2Y5  
4F.G.  
MADE IN JAPAN  
Shield  
R1/4  
Case  
22)  
17-4PH  
SUS304)  
ꢀꢁPA-968  
ꢀꢁFittingG3G 3/8)  
1
2
BrownPower(+)  
45±1  
5.7  
10  
Pressure port  
Pressure  
With Snubber  
12  
6.5 min  
BlackAnalog Output  
Blue Calibration  
Marking  
Sensor  
Main circuit  
3
4CAL  
Shield  
-
-
PA 96 104P-G3  
*
Lot.2Y5  
MADE IN JAPAN  
O-Ring  
Fluororubber)  
G3/8  
(17-4PH)  
Case  
SUS304  
22)  
M12 ASSEMBLED CABLEꢀ  
WIRING  
(Unit:mm)  
Please wire according to the following table for M12 connec-  
ꢀꢁStraight  
tor cable.  
1000±100  
M12×1  
I/O Connector  
3.5)  
45)  
53  
±
5
6±2  
2
3
1
M12 Connector Cable  
4-pin/3-core×AWG22  
4
ꢀꢁAngle  
1000±100  
Connection  
Pin  
No.  
31)  
53  
±
5
6±2  
PA-960  
PA-968  
Power  
1
2
3
4
Power⊕  
Analog output  
Common  
F.G.  
Analog output  
CAL**  
M12 Connector Cable  
4-pin/3-core×AWG22  
CAL**  
F.G:Frame ground  
Do not wire the CAL connection.  
It may cause malfunction when voltage is applied.  
**…Calibration  

相关型号:

PA-960-503P-G3-1

THIN-FILM HIGH PRESSURE TRANSDUCER
NIDEC

PA-960-503P-G3-2

THIN-FILM HIGH PRESSURE TRANSDUCER
NIDEC

PA-960-503P-R2-1

THIN-FILM HIGH PRESSURE TRANSDUCER
NIDEC

PA-960-503P-R2-2

THIN-FILM HIGH PRESSURE TRANSDUCER
NIDEC

PA-960_16

THIN-FILM HIGH PRESSURE TRANSDUCER
NIDEC

PA-968

THIN-FILM HIGH PRESSURE TRANSDUCER
NIDEC

PA-DSO-0803

ADAPTER 8 PIN DIP BOARD.
ETC

PA-DSO-1403-D250-14/2

ADAPTER 14-DIP BD W/2 14-SO PLUG
ETC

PA-DSO-1603Z

ADAPTER 16-DIP BD W/ZIF SOCKET
ETC

PA-DSO-1803

ADAPTER 18-DIP BOARD
ETC

PA-DSO-1803Z

ADAPTER 18-DIP BD W/ZIF SOCKET
ETC

PA-DSO-1803Z-D420-18/2

ADAPTER 18 ZIF BD W/18SO PLUGS
ETC