TF037F-2000-P [NIDEC]

BLOWER OUTLINE;
TF037F-2000-P
型号: TF037F-2000-P
厂家: NIDEC COMPONENTS    NIDEC COMPONENTS
描述:

BLOWER OUTLINE

文件: 总9页 (文件大小:304K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
1
7
/
NIDEC COPAL ELECTRONICS CORP.  
Model No.  
TF037F-2000-P  
Specifications  
Issuing Date  
Aug.4, 2017  
1. Scope  
This specification applies to Blower Kit:TF037F-2000-P (hereinafter referred to as "the PRODUCT"),  
a product of NIDEC COPAL ELECTRONICS CORP. (hereinafter referred to as "NCEL").  
Contents of the kit are Micro Blower:TF037F-2000-F, Driver board, Harness (2 types) and  
Instruction manual.  
2. Specification  
(Note1)  
(Note2)  
(Note3)  
Unless otherwise specified, the environmental conditions are 23℃±5℃,normal humidity, and  
atmospheric pressure range 90 to 106kPa.  
Measuring conditions :  
Supply voltage = DC24V, measurement equipment = NCEL's standard equipment  
This specification represents the characteristics at the time of product shipment. Changes in  
characteristics over time are not covered by this specification.  
No.  
1
Items  
Specification  
Remarks  
Rated Voltage  
DC 24 V±10%  
Direction of Rotation  
Kind of Gas  
(Counter-Clockwise)  
2
3
4
5
6
7
8
9
CCW  
Air  
Viewed from top of air inlet.  
Noncorrosive gas  
Configuration  
Type of Motor  
Number of Poles  
Drive System  
Bearings  
Motor with Centrifugal Turbo Blade  
DC Brushless Motor  
Driving circuit required separately  
Poles  
( 4 pole pairs)  
8
3 Phase, Bipolar  
Aero-Dynamic Bearings  
Impeller  
Centrifugal Turbo Blade  
Micro Blower : 6404-00635-00 (Drawing)  
Driver Board : 6404-00431-01 (Drawing)  
10  
Outline  
Please refer to attached drawing.  
No vibration, shock, or gyration  
to be applied to the product  
operation.  
Shaft vertical to ground, air inlet facing  
upwards  
11 Mounting Direction  
Rated Rotation  
(reference value)  
31,000 r/min  
12  
Speed  
at 2.0kPa, 100L/min  
Max. Input Coil  
Current  
Rated Power Supply  
max. (rms)  
13  
3.0 A  
0.67 A  
29 W  
Excluding inrush current.  
at Rated Voltage=DC 24V  
at 2.0kPa, 100L/min  
at Rated Voltage=DC 24V  
at 2.0kPa, 100L/min  
max. (reference value)  
max. (reference value)  
14  
Current  
Rated Power  
Consumption  
15  
2
7
/
NIDEC COPAL ELECTRONICS CORP.  
No.  
16  
17  
18  
19  
20  
21  
Items  
Specification  
100 L/min  
Remarks  
Rated Air Flow  
at 2.0kPa  
Minimum Air Flow  
Rated Pressure  
10 L/min  
at 100L/min  
2.0 kPa  
Maximum Pressure  
Torque Constant  
Min. Rotation Speed  
4.5kPa  
(absolute maximum pressure)  
0.0026 N・m/A (reference value)  
10,000 r/min  
at 2.0kPa, 100L/min  
Measured at 1m from air inlet  
Background noise 15dB(A)  
Acoustic Audible Noise  
65.0 dB(A) max.  
22  
Coil Resistance  
Coil Inductance  
(reference value)  
(reference value)  
at 20℃ (Between 2 phase)  
23  
24  
25  
26  
27  
0.55 Ω  
23 μH  
Class E  
at 20℃, 10kHz (Between 2 phase)  
Insulation Class  
JIS C 4003  
DC500V,between terminal pins and plate  
JIS C 4003  
AC600V for 1sec. between  
Insulation Resistance  
Dielectric Strength  
ohm min.  
1M  
Leak current to be less than 1mA  
JIS C 4003  
terminal pins and plate  
Micro Blower ︓72g  
Weight  
28  
(reference value)  
Driver Board ︓32g  
19 g・cm2  
Rotor Inertia  
(reference value)  
29  
30  
31  
32  
33  
34  
Max. allowable force to the intake  
(upper housing) in axial direction.  
Max. Axial Loading  
max.  
3 N  
Operating  
Temperature Range  
Operating  
Humidity Range  
Storage  
Temperature Range  
Storage  
Humidity Range  
0 〜 50℃  
10 〜 80%RH  
-20 〜 60℃  
No condensation  
No condensation  
10 〜 90%RH  
Satisfy Spec No.12 〜 27 after the following test;  
Kind of  
Frequency veering  
Vibration  
10〜22Hz  
@ amplitude 1mm  
Resistance to  
Vibration  
Frequency  
Range  
35  
Non-operating  
@ acceleration  
19.6m/s2 (2G)  
22〜50Hz  
Sweep  
To-and-fro, approx. 5min.  
Test Time X, Y, Z directions, 60min. each  
Satisfy Spec No.12 〜 27 after the following test;  
294m/s2(30G)  
Acceleration  
Resistance to  
Shock  
Pulse Width  
36  
6ms  
Non-operating  
Shock Wave Semi-sinusoidal wave  
Number of X, Y, Z, directions, once per each  
Shock  
direction  
3
7
/
NIDEC COPAL ELECTRONICS CORP.  
3. Interface  
【Micro Blower】  
Pin No. Symbol  
Signal  
Air Inlet  
Hall Element Power Supply  
(+12V)  
1
Vcc  
2
3
4
5
6
7
8
H2-  
H2+  
H3-  
H3+  
H1-  
H1+  
GND  
Hall Element 2 Output  
Hall Element 3 Output  
Manufacturer  
Part No.  
Hall Element 1 Output  
GND  
ꢀJ.S.T. Mfg. Co., Ltd.  
ꢀSM12B-PASS  
Thermistor Output  
9
TH  
Motor Coil (V)  
Motor Coil (W)  
Motor Coil (U)  
10  
11  
12  
V
W
U
【Driver Board】  
CN1  
(for Control)  
CN3  
(for Blower)  
12  
1
6
1
CN1︓Connector for Control  
CN3︓Connector for Blower  
Manufacturer  
Manufacturer  
J.S.T. Mfg. Co., Ltd.  
J.S.T. Mfg. Co., Ltd.  
Part No. ꢀSM06B-PASS  
Pin No. Symbol  
Part No.  
ꢀSM12B-PASS  
Signal  
Error Output  
Pin No. Symbol  
Signal  
Motor Coil (U)  
1
2
3
4
5
U
W
1
2
3
4
5
6
Error  
FG  
Rotational Speed Signal  
Output (FG)  
Motor Coil (W)  
Motor Coil (V)  
V
BR  
Short brake Input  
Thermistor Output  
GND  
TH  
GND  
CNT  
Vcc  
GND  
Control Voltage Input  
Power Supply Voltage  
Input  
6
7
8
9
10  
11  
H1+  
H1-  
H3+  
H3-  
H2+  
H2-  
Hall Element 1 Output  
Hall Element 3 Output  
Hall Element 2 Output  
GND  
Connect the Micro Blower and Driver Board with  
the supplied Motor harness.  
(Attached harness)  
Power supply harness  
Motor harness  
1 piece  
1 piece  
Hall Element Power Supply  
(+12V)  
12  
Vcc  
4
7
/
NIDEC COPAL ELECTRONICS CORP.  
4.CN1(Connector for Control)Specification  
Pin No. Symbol  
Specification  
Error Output  
1
Error  
Micro-controller  
<Driver side>  
1
L=Undetected  
Error  
H=Detection  
Rotational Speed Signal Output  
2
FG  
(FG)  
Tr1  
12 pulse / rev.  
(RT1N441U)  
2
FG  
(FG)  
Open Collector Output  
Max. Voltage : 50V  
Max. Output Current : 3mA  
Short brake Input  
L=Rotation  
H=Short brake  
<Driver side>  
3
BR  
(BR)  
100p  
4.7kΩ  
GND  
3
4
BR  
Control Voltage Input  
<Driver side>  
100kΩ  
Input Voltage for  
0V  
(LB8503V)  
100kΩ  
Standby  
+
CNT  
(VERR)  
4
CNT  
IC  
Input Voltage for  
1.0 to 5.0V  
Operation  
(FG)  
<Driver side>  
Power Supply Voltage Input  
DC24V±10%  
5
Vcc  
+
5
6
Vcc  
220μF  
6
GND  
GND  
GND  
5.Operating Range  
Conditions: Ambient temperature 23±5℃, normal humidity, atmospheric pressure (100±2kPa).  
Operating range will be discussed separately.  
The following graph is provided for reference only. Values are not guaranteed.  
Make sure the thermistor temperature does not exceed 86℃ during blower operation.  
(Thermistor resistance value R(86 deg C)=0.968kΩ)  
Operating Range at DC24V (1atm)  
5.0  
40,000r/min  
4.0  
35,000r/min  
3.0  
Area of use  
30,000r/min  
2.0  
25,000r/min  
1.0  
0.0  
0
20  
40  
60  
80  
100  
120  
140  
160  
Air Flow [L/min]  
5
7
/
NIDEC COPAL ELECTRONICS CORP.  
6.Protective Functions  
ꢀAttached Driver Board[TF037E-1000-D] is featured with the following protective functions.  
Protective  
Description  
Functions  
High  
Temperature  
Power will be turned off when the thermistor inside the Blower exceeds 86℃.  
High  
Power will be turned off when the rotational speed exceeds 45,000 r/min.  
Temperature  
Overcurrent Power will be turned off when the coil current exceeds 1.9A (except start-up).  
Power will be turned off when coil current and rotational speed are in the "Motor  
Lock Protection Area" shown in Graph 2 below.  
Motor Lock 1  
Power will be turned off when the Blower does not operate even when the PRODUCT  
Motor Lock 2  
is giving command to operate.  
Graph 2. Protective Area  
2.5  
2.0  
1.5  
1.0  
0.5  
Overcurrent Protective Area  
(37,000r/min,1.9A)  
High  
Rotational  
Speed  
Motor Lock 1 Protective Area  
Area of Use  
(28,000r/min,1.0A)  
Protective  
Area  
(0r/min,0.5A)  
(21,000r/min,0.5A)  
0.0  
0
10000  
20000  
30000  
40000  
50000  
Rotational Speed [r/min]  
ꢀ【Monitor / Control Flow】  
Monitored Items  
Protective  
Functions  
Criteria  
Control  
CNT V  
1.0〜5.0V  
Thermistor  
temperature  
High  
Temperature  
Thermistor 86℃ or higher  
45,000r/min or higher  
High  
Rotational  
Rotational speed  
Coil current  
Shunt resistant current  
1.9A or higher  
Overcurrent  
Motor Lock 1  
Motor Lock 2  
Blower Stop  
Motor Lock 1 Protective Area  
Rotation failure of Blower  
《 Restart Conditions After Blower Stop》  
Restart with turning the power on again.  
6
7
/
NIDEC COPAL ELECTRONICS CORP.  
7.Manufacturing Code  
【Micro Blower】  
Control no.  
︓alphabet (A-Z)  
︓refer to Chart 1  
︓refer to Chart 2  
Date of manufacture  
Month of manufacture  
Year of manufacture  
last digit of the year  
(A.D.)  
【Driver Board】  
Lot No.  
With lead ︓Brank  
Without lead ︓F  
7
6
1
F
X
X
X
X
12  
1
6
Control no.  
︓alphabet (A-Z)  
︓refer to Chart 1  
︓refer to Chart 2  
Date of  
manufacture  
Month of  
manufacture  
Year of  
manufacture  
1
last digit of the year  
(A.D.)  
【Chart 1】  
Date  
Code  
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10 11 12 13 14 15 16 17 18 19 20  
A
B
C
D
E
F
G
H
J
K
L
21 22 23 24 25 26 27 28 29 30 31  
Date  
Code  
M
N
P
Q
R
T
U
V
W
X
Y
【Chart 2】  
Month  
Code  
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10 11 12  
O
N
D
8.Warranty  
ꢀ8-1.Warranty Period  
Warranty period of the PRODUCT is 1 year from delivery.  
ꢀ8-2.Warranty Scope  
In case a defect is found in the PRODUCT during the above warranty period and NCEL is responsible for  
the defect, NCEL will either repair or replace the defected PRODUCT free of charge.  
However, in the following cases, the PRODUCT will not be covered by warranty.  
(1)  
Defects caused by inappropriate conditions, environments, handlings, and use which are not specified in  
this specification.  
Defects caused by your equipments and/or software.  
Defects caused by modifications and/or repairs which were not done by NCEL.  
Defects which could have been avoided if the PRODUCT was used accordingly to this specification.  
Defects which were unpredictable with the scientific or technical level of NCEL at the time of shipment.  
Defects caused by external factors such as natural hazards (fire, earthquakes, floods) or electrical  
(2) NCEL will be responsible for the PRODUCT only in which the coverage will be limited to Clause 8-2. (1).  
NCEL shall not be liable for customer's equipment damages, opportunity losses, or lost earnings caused by  
defects of the PRODUCTS. The user shall indemnify NCEL and hold NCEL harmless from any liability or  
damage whatsoever arising out of any action not in accordance with this specification.  
7
7
/
NIDEC COPAL ELECTRONICS CORP.  
ꢀ 8-3.Product Application  
The PRODUCT is designed and manufactured for general industrial use for general-purposes. Please do not  
use in applications such as nuclear power, aviations, railroads, or medical equipment where great effect to  
human lives or wealth are expected.  
However,if NCEL agree with the customer the usage of the PRODUCT in such applications, NCEL will warrant  
the PRODUCT in the same scope described in "8. Warranty" in this specification.  
9.Notes  
(1)  
(2)  
All values are measured with NCEL's standard equipments unless otherwise specified.  
The PRODUCT is compliant with RoHS directives which went into effect July, 2011.  
Designated hazardous substances are lead, mercury, cadmium, hexavalent chrome, brominated flame  
retardants (PBB, PBDE) and its compounds.  
(3)  
(4)  
The PRODUCT is compliant with Directive 2006/122/EC of the European Parliament (Council Directive  
76/769/EEC(30th amendment)) which restricts the use of PFOS.  
Contents of this document may be changed without notice. The production of the PRODUCT may be  
discontinued without notice. ꢀPlease confirm with your local contact before ordering.  
Please check if the PRODUCT operates normally at every start-up and during operation.  
Please provide safety measures to prevent damages in case of product failures.  
Performance cannot be guaranteed in case the PRODUCT is used beyond the specification or the PRODUCT  
is modified.  
(5)  
(6)  
(7)  
(8)  
Depending on the conditions or the environment, functions or performances of the PRODUCT may not be  
satisfied when the PRODUCT is used with other equipments.  
Please do not use the PRODUCT in applications to protect the body.  
Please protect the PRODUCT from condensation.  
Please use the correct supply voltage to operate the PRODUCT.  
Do not disassemble or modify the PRODUCT.  
(9)  
(10)  
(11)  
(12)  
(13)  
Turn off the power immediately and stop using the PRODUCT in the following cases.  
In case water or foreign substances get into the PRODUCT.  
In case the PRODUCT is dropped or the housing is broken.  
In case unusual odor, abnormal noise, or smoke are generated from the PRODUCT.  
(14)  
Do not use or store in the following conditions;  
Humid, dusty, or poorly-ventilated area.  
Areas where the temperature is expected to rise (direct sunlight, etc.).  
Areas with corrosive gas or flammable gas in the surrounding air.  
Areas where vibration, shock, or rocking motion is applied directly to the PRODUCT.  
Areas where the PRODUCTS may be splashed with water, oil, or chemicals.  
Areas where static electricity can easily be built up.  
(15)  
(16)  
Make sure the wiring is done properly.  
Turn off the power of the PRODUCT and any equipment attached to the PRODUCT when putting on or  
taking off the cables.  
(17)  
(18)  
(19)  
Install the PRODUCT using cushioning materials such as vibration dampeners. Please contact NCEL if you  
have any questions regarding installation.  
Do not block the air inlet and outlet (3 places). Please contact NCEL if you have any questions regarding  
the air inlet and outlet.  
Vibration or audible noise level may change over time due to contamination of the blade. Please provide  
dust-proof constructions around the PRODUCT.  
Please advise us in case the driving circuit will be designed at the customer's side.  
Please connect and don't use air inlet of this product (2 places) in series.  
(20)  
(21)  

相关型号:

TF04010100J0G

Barrier Strip Terminal Block
AMPHENOL

TF04014000J0G

Barrier Strip Terminal Block
AMPHENOL

TF04014100J0G

Barrier Strip Terminal Block
AMPHENOL

TF04014200J0G

Barrier Strip Terminal Block
AMPHENOL

TF04015200J0G

Barrier Strip Terminal Block
AMPHENOL

TF04016000J0G

Barrier Strip Terminal Block
AMPHENOL

TF04016100J0G

Barrier Strip Terminal Block
AMPHENOL

TF04019100J0G

Barrier Strip Terminal Block
AMPHENOL

TF0402B-04P-03

Single Phase EMI Filter
TDK

TF0402B-05P-01

Single Phase EMI Filter
TDK

TF0402B-05P-03

Single Phase EMI Filter
TDK

TF0402S-01

Single Phase EMI Filter, 50V,
TDK